ATK-I 5/20/30

Current Sensor

Overview

The ATK-I 5/20/30 provides economical and precise solutions for AC or DC

current sensing in industrial, automotive, commercial, and communications

systems. The device package allows for easy implementation by the customer.

Typical applications include motor control, load detection and management,

switched-mode power supplies, and over-current fault protection.

Features

Operating Voltage: 4.5V to 5V

Current detecting range 5A/20A/30A depend upon Module No.

Onboard visual indicator (LED).

Compaq design and easily mount.

Simple 3 PIN header interface.

Analog output.

Sensitive to magnetic field.

Applications

Consumer electronics

Motor control

Load detection and management

Switched-mode power supplies

Over-current fault protection

2

Specifications

Parameter Min Typ Max Units

Working Voltage 4.5 5 8 Volts

Range 5/20/30 Amp

Part No Range Sensitivity

ATK-I 05 ±5Amp 185mV/A

ATK-I 20 ±20Amp 100mV/A

ATK-I 30 ±30Amp 66mV/A

Pin Diagram

Pin Pin Name

Pin Name

+5V Power Supply Regulated 5V supply input

GND Ground Ground level of power supply

OUT Output Output for external devices

1(Green

connector) Input supply line 1

2(Green

connector

To the device to

be measure 2

(VIOUT(Q)). The output of the sensor when the primary current is zero. For a

unipolar supply voltage, it nominally remains at VCC ⁄ 2. Thus, VCC = 5 V

translates into VIOUT(Q) = 2.5 V. Variation in VIOUT(Q) can be attributed to the

resolution of the Allegro linear IC quiescent voltage trim and thermal drift.

For No current output value is 2.5V

3

Note: Always connect the measuring device to the green connector. The green

connector should be in series with supply line.