HIGH CARRYING CURRENT TYPE SMALL & SLIM
AUTOMOTIVE RELAYCT RELAYS (ACTP)
FEATURES• Maximum carrying current of 35A
made possible through using the same size as the company’s CT relays
• Plastic sealed type
TYPICAL APPLICATIONS• Power windows• Auto door lock• Power sunroof• Powered seats• Slide door closers, etc. (for DC motor
forward/reverse control circuits)
CT (ACTP)
1ds_61205_en_ct_power: 010113J
ORDERING INFORMATION
P: Power type
ACT P
Coil voltage, DC12: 12 V
Contact arrangement1: 1 Form C2: 1 Form C×2 (8 terminal)5: 1 Form C×2 (10 terminal)
TYPESContact arrangement Coil voltage Part No.
1 Form C12 V DC
ACTP1121 Form C 2 (8 terminals type) ACTP212
1 Form C 2 (10 terminals type) ACTP512Standard packing; 1 Form C: Carton (tube) 30pcs. Case 1,500pcs.; 1 Form C 2: Carton (tube) 30pcs. Case 900pcs.
RATING1. Coil data
Nominal coil voltage
Pick-up voltage (at 20C 68F)
Drop-out voltage (at 20C 68F)
Nominal operating current
[10%] (at 20C 68F)
Coil resistance [10%] (at 20C 68F)
Nominal operating power
(at 20C 68F)Usable voltage range
12V DC Max. 7.2 V DC (Initial) Min. 1.0 V DC (Initial) 83.3 mA 144 1,000 mW 10 to 16V DCNote: Other pick-up voltage types are also available. Please contact us for details.
-
CT (ACTP)
2 ds_61205_en_ct_power: 010113J
2. SpecificationsCharacteristics Item Specifications
ContactArrangement 1 Form C 2, 1 Form CContact resistance (Initial) N.O.: Typ 7m, N.C.: Typ 10m (By voltage drop 6V DC 1A)Contact material Ag alloy (Cadmium free)
Rating
Nominal switching capacity (resistive load) N.O.: 30 A 14V DC, N.C.: 10 A 14V DCMax. carrying current (14V DC)*3 N.O.: 40 A for 2 minutes, 25 A for 1 hour at 20C 68F, 35 A for 2 minutes, 20 A for 1 hour at 85C 185FNominal operating power 1,000 mWMin. switching capacity (resistive load)*1 1 A 14V DC
Electrical characteristics
Insulation resistance (Initial) Min. 100 M (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
Breakdown voltage (Initial)
Between open contacts 500 Vrms for 1 min. (Detection current: 10mA)Between contacts and coil 500 Vrms for 1 min. (Detection current: 10mA)
Operate time (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)Release time (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)
Mechanical characteristics
Shock resistance
Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s)Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
Vibration resistance
Functional 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10s)
Destructive 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G},
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected life
Mechanical Min. 107 (at 120 cpm)
Electrical
Min. 5 104 (at nominal switching capacity, operating frequency: 1s ON, 9s OFF)
N.O. side: Min. 105 (at Inrush 30A, Steady 7A 14 V DC),
Min. 5 104 (at 30A 14 V DC motor lock condition)N.C. side: Min. 105 (at brake current 15A 14 V DC) (operating frequency: 0.5s ON, 9.5s OFF)
ConditionsConditions for operation, transport and storage*2
Ambient temperature: –40C to +85C –40F to +185F, Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 6 cpm (at nominal switching capacity)Mass Twin type: approx. 8 g .28 oz, 1 Form C type: approx. 4 g .14 oz
Notes:*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F).
*3. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions. If the relay is used continuously for long periods of time with coils on both sides in an energized condition, breakdown might occur due to abnormal heating depending on
the carrying condition. Therefore, please inquire when using with a circuit that causes an energized condition on both sides simultaneously.
REFERENCE DATA1-(1). Coil temperature rise (at room temperature)Sample: ACTP212, 3pcs.Contact carrying current: 0A, 10A, 20AAmbient temperature: Room temperature
0
20
40
60
80
100
120
140
160
12 14 16
20A
10A0A
Coil applied voltage, V
Tem
pera
ture
ris
e, °
C
1-(2). Coil temperature rise (at 85C 185F)Sample: ACTP212, 3pcs.Contact carrying current: 0A, 10A, 20AAmbient temperature: 85C 185F
0
20
40
60
80
100
120
140
160
12 14 16
20A
10A0A
Coil applied voltage, V
Tem
pera
ture
ris
e, °
C
2. Ambient temperature and operating voltage range
0
5
10
15
35
30
25
20
40
-40 -20 20 40 60 1000 1208085Ambient temperature, °C
Coi
l app
lied
volta
ge, V
DC
Pick-up voltage(Cold start)
Operating voltage range
http://www.panasonic-electric-works.com/peweu/en/downloads/ds_x61_en_relay_technical_information.pdf
-
3. Distribution of pick-up and drop-out voltageSample: ACTP212, 80pcs.
0
30
20
10
40
50
1.50 1 2.0 2.5 3.0 3.5 4.5 5.04.0 5.5 6.0 6.5 7.0 7.5
Voltage, V
Qua
ntity
, n
Pick-up voltageDrop-out voltage
4. Distribution of operate and release timeSample: ACTP212, 80pcs.
0
30
40
50
60
20
10
1.00.8 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8
Operate timeRelease time
Operate and release time, ms
Qua
ntity
, n
* Without diode
5. Electrical life test (Motor free)Sample: ACTP212, 3pcs.Load: Inrush 30A, Steady 7ABrake current: 15A 14V DC, Power window motor actual loadOperating frequency: ON 0.5s, OFF 9.5sAmbient temperature: Room temperatureCircuit:
M
Sample
Change of pick-up and drop-out voltage
0
2
4
6
8
10
0 5 10
X
XMax.
Max.
Min.
Min.
Contact welding: 0 timeMiscontact: 0 time
No. of operations, × 104
Pic
k-up
and
dro
p-ou
t vol
tage
, V
Pick-up voltage
Drop-out voltage
Change of contact resistance
0
Max.
Min.X
50
40
30
20
10
0 105
No. of operations, × 104
Con
tact
res
ista
nce,
mΩ
Load current waveformInrush current: 30A, Steady current: 7ABrake current: 15A
100ms
10A
CT (ACTP)
3ds_61205_en_ct_power: 010113J
-
6. Electrical life test (Motor lock)Sample: ACTP212, 3pcs.Load: 30A 14V DCOperating frequency: ON 0.5s, OFF 9.5sAmbient temperature: Room temperature
Circuit:
M
Sample
Change of pick-up and drop-out voltage
0
2
4
6
8
10
0 2.5 5No. of operations, × 104
Pic
k-up
and
dro
p-ou
t vol
tage
, V
X
XMax.
Max.
Min.
Min.
Pick-up voltage
Drop-out voltage
Contact welding: 0 timeMiscontact: 0 time
Change of contact resistance
0
Max.
50
40
30
20
10
0 52.5
Min.X
No. of operations, × 104
Con
tact
res
ista
nce,
mΩ
Load current waveform
100ms
10A
CT (ACTP)
4 ds_61205_en_ct_power: 010113J
DIMENSIONS (mm inch) Download from our Web site.CAD DataCAD Data
1. Twin type (8 terminals)CAD Data
Dimension: ToleranceMax. 1mm .039 inch: 0.1 .0041 to 3mm .039 to .118 inch: 0.2 .008Min. 3mm .118 inch: 0.3 .012
* Dimensions (thickness and width) of terminal is measured before pre-soldering.Intervals between terminals is measured at A surface level.
Tolerance: 0.1 .004
External dimensions
0.4
3.5
1 10.3
Max. 1.0.039
*A
Pre-soldering1.25
3.15
3
1.45
13.5
0.4
0.8 0.4 0.4
9.5
4.3
2.5
4.3
1417.4
15
6.8
1
6
.016
.138
.039 .039.012
.049
.124
.118
.057
.531
.016
.031 .016 .016
.374
.169
.098
.169
.551.685
.591
.268
.039
.236
PC board pattern (Bottom view)
Schematic (Bottom view)
3.15
4.3
4.3
2.5
6.8
4×1.1 dia.+0.1 0+0.04 0
9.5
6
3
15
4×1.4 dia.+0.1 0+0.04 0
.124
.169
.169
.098
.268
.374
.236
.118
.591 4×.043 dia.4×.055 dia.
NC
NO
COM
COM
COIL
COIL
http://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.php
-
2. Twin type (10 terminals)CAD Data
Dimension: ToleranceMax. 1mm .039 inch: 0.1 .0041 to 3mm .039 to .118 inch: 0.2 .008Min. 3mm .118 inch: 0.3 .012
* Dimensions (thickness and width) of terminal is measured before pre-soldering.Intervals between terminals is measured at A surface level.
Tolerance: 0.1 .004
External dimensions
0.4
3.5
1
10.3
Max. 1.0.039
*A
Pre-soldering
0.8
1.25
6.83.15
3.15
0.65
0.65
1.45
17.4
13.5
0.4
0.4 0.4
14
9.5
6
15
4.3
2.5
4.3
1
.016
.138
.039
.039.012 .031
.049
.268.124
.124
.026
.026
.057
.685
.531
.016
.016 .016
.551
.374
.236
.591
.169
.098
.169
.039
PC board pattern (Bottom view)
Schematic (Bottom view)
3.15
3.15
0.65
0.65
4.3
4.3
2.5
6.8
9.5
6
15
6×1.4 dia.+0.1 0+0.04 0
4×1.1 dia.+0.1 0+0.04 0
.124
.124
.026
.026
.169
.169
.098
.268
.374
.236
.591
6×.055 dia.
4×.043 dia.
COM
NO
COM
NO
NC
NC
COIL
COIL
3. Single type (1 Form C)CAD Data
Dimension: ToleranceMax. 1mm .039 inch: 0.1 .0041 to 3mm .039 to .118 inch: 0.2 .008Min. 3mm .118 inch: 0.3 .012
* Dimensions (thickness and width) of is measured before pre-soldering.Intervals between terminals is measured at A surface level.
Tolerance: 0.1 .004
External dimensions
0.4
3.5
11
0.3
Max. 1.0.039
*A
Pre-soldering1.25
3.15
1.45
13.5
0.4
0.8
0.4 0.4
9.5
4.3
7.217.4
1
0.65
6
15
.016
.138
.039.039
.012
.049
.124
.057
.531
.016
.031
.016 .016
.374
.169
.283.685
.039
.006
.236
.591
PC board pattern (Bottom view)
Schematic (Bottom view)
3.15 4.3
2×1.1 dia.+0.1 0+0.04 015
0.65
9.5
6
3×1.4 dia.+0.1 0+0.04 0
.124 .169
.591.026
.374
.236
2×.043 dia.
3×.055 dia.
NO
COM NC
COIL
CT (ACTP)
5ds_61205_en_ct_power: 010113J
For Cautions for Use, see Relay Technical Information.
http://www.panasonic-electric-works.com/peweu/en/downloads/ds_x61_en_relay_technical_information.pdfhttp://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.phphttp://www.panasonic-electric-works.com/peweu/en/html/27524.php