DFT designs products using the latest CAD, FEA, and CFD design technology software and manufactures in Exton, PA.
Control Valves for Severe Service Applications
DFT® HI-100® Control Valve Features an In-Line Straight-Thru Venturi Flow Design
1
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
DFT® Model HI-100® Severe Service Parameters• Pressuredifferential>1000psi(69bar)• Temperatures>800ºF(427ºC)• Highlyerosiveand/orcorrosiveservice• Servicewithentrainedwaterdropletssuchaswetsteam andmixedphaseapplications• Lightslurryservice• Buffetingorpulsatingfluid
Valve DesignTheHI-100® Control Valvefeaturesanin-linestraight-thruventuriflowdesign.Thecontrolelement,asphericalball,iscontainedbyacagethatpositionstheballrelativetothedownstreamseatbymeansoflinearstemtravel.Therearenocloseclearancesbetweenthemovingparts(i.e.cage,ballandseat).Thesefeaturesenablethevalvetooperatesmoothlyandefficientlyathighorlowtemperaturesand/orinfluidscarryingsuspendedparticlessuchasslurries.FCI70ClassVshutoffisstandard.
Control Valves for Severe Service Applications
DFTdesignsproductsusingthelatestCAD,FEA,andCFDdesigntechnologysoftwareandmanufacturesinExton,PA.
HI-100® Product Line•ValveBodySizes:1”to12”*•TrimSizes:¼”to8”•PressureClass:ASME150to4500•StandardBodyMaterials: CarbonSteel,StainlessSteeland Chrome-moly•EndConnections:WeldEndandFlanged•StemSeal:Live-loadingPacking•ToporBottomEntrytoInternalTrim•FlowCharacteristics: LinearorEqualPercentage
Stem
Upstream Wear Bushing
Cage
DownstreamSeat
Cartridge Assembly Guide Pin
Ball
*Largersizes,consultfactory.
2
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
DFT® HI-100®
HI-100®/MSV-100®/Ultra-Trol® Flow CharacteristicsTheclassicDFTdesignhasalinearflowcharacteristic.Thischaracteristicgivesthebestflowcontroloverthewidestrange.DFT’sventuri-balldesignistheonlydesignthatactuallyworkswiththephysicsofthefluidflow.Incomingflowentersthroughthenozzletothecontrolarea.Thesmoothlyconvergingnozzlelowersturbulenceastheflowmovesaroundthecurvedcontrolpath.Notethatonlyroundedsurfacesandconesareusedforthecontrolfunction.Astheflowexitsthevalve,thedivergingnozzlecontrolsexpansionandrecoverysothatnoturbulenceisaddedtotheflowstream.Thisdesignprovidesasuperior,smoothflowcontrol.Thepreferredoperatingrangeofthevalveisbetween15%and90%open.
Flow Characteristics
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
% of M
axim
um Flow
Valve Percent Open
Venturi Ball Flow Characteristics
*Standardmaterialsofconstructionareshown.Thesematerialscanbemodifiedforspecialapplications.Contactthefactoryformoreinformation.DFT®andHI-100®areRegisteredTrademarksofDFTInc.Allothertrademarksarethepropertiesoftheirrespectiveownersandareusedforpurposesofidentificationonly.
BODYBody / Bonnet(normally matches pipe) A105 F22 or F11 A479-316
Cage: 1/4” to 2” Cast Stellite® #6
Cage: 2-1/2” & Larger WC6 w/Stellite® #6 Hardfacing CF8M/Stellite® #6
Cartridge A351 CF8M
Guide Pin A193 B7 A193 B8M
Gland/ Follower 303 SS
TRIM STYLETrim Code (A) (B) (C) (D)
Stem Trim 17-4 PH A286 A286
Ball: 1/4” to 4” PSZ Ceramic 440C Stellite® Stellite®
Ball: 6” and Larger Stellite® #6
Seat: 1/4” to 2” 440C Stellite® #6 Stellite® #6
Seat: 2-1/2” & Larger 440C 316 SS/Stellite® 316 SS/Stellite®
Wear Bushing 440C Stellite® #6
APPLICATION TRIM CODE APPLICATION TRIM CODEBoiler Feed Pump Bypass A Drum Level Control B
Auxiliary Steam Control C Attemperator Spray Control C
Sootblower Control (Hi-Temp) D Turbine Bypass C
Feed Water Control B Turbine and Boiler Drain B
Materials of Construction* and Application Guide
3
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
Face to Face Dimensions
Nominal Valve Size
HI-100 Face to Face Dimensions*
ASME Class 150 ASME Class 300 ASME Class 600 ASME Class 900 ASME Class 1500 ASME Class 2500
NPS DN in mm in mm in mm in mm in mm in mm
1/4 8 4.00 102
3/8 10 4.00 102
1/2 15 4.25 108 6.00 152 6.50 165 8.50 216 8.50 216 10.38 264
3/4 20 4.62 117 7.00 178 7.50 190 9.00 229 9.00 229 10.75 273
1 25 5.00 127 8.00 203 8.50 216 10.00 254 10.00 254 12.12 308
1 1/4 32 5.50 140 8.50 216 9.00 229 11.00 279 11.00 279 13.75 349
1 1/2 40 6.50 165 9.00 229 9.50 241 12.00 305 12.00 305 15.12 384
2 50 8.00 203 10.50 267 11.50 292 14.50 368 14.50 368 17.75 451
2 1/2 65 8.50 216 11.50 292 13.00 330 16.50 419 16.50 419 20.00 508
3 80 9.50 241 12.50 318 14.00 356 15.00 381 18.50 470 22.75 578
4 100 11.50 292 14.00 356 17.00 432 18.00 457 21.50 546 26.50 673
6 150 16.00 406 17.50 445 22.00 559 24.00 610 27.75 705 36.00 914
8 200 19.50 495 22.00 559 26.00 660 29.00 737 32.75 832 40.25 1022
*DimensionsperASMEB16.10.Valvescanbesuppliedtomeetenduserrequirements.Class4500andhigherpressurevalvesaresuppliedtomeetenduserrequirements.
RAISEDFACE
DFT® HI-100®
BUTTWELDEND
DFT®andHI-100®areRegisteredTrademarksofDFTInc. *Largersizesconsultfactory.
HI-100 Maximum Valve Flow Coefficient
Size NPS 1/4 3/8 1/2 3/4 1 1 1/4 1 1/2
SizeDN 8 10 15 20 25 32 40
Cv (Kv) 1 (0.9) 2.5 (2.2) 4.5 (3.9) 10 (8.6) 20 (17) 31 (27) 45 (39)
Size NPS 2 2 1/2 3 4 6 8
SizeDN 50 65 80 100 150 200
Cv (Kv) 80 (69) 125 (108) 180 (155) 320 (275) 720 (621) 1280 (1103)
A A
4
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
Closed PositionIntheclosedposition,pressuremovestheballintotheconicalseatingsurfaceandholdsitinplace.Linecontactbetweentheballandtheseatresultsinhighsurfaceloadsbetweentheseatandtheballproducingtightclosure.Aspres-sureincreases,theseatloadincreasesimprovingtheseal.Duringeachvalvestroke,theballrotatesandrepositionsitselfpresentinganewsealingsurfacetotheseat,prolongingthetightshutoffcapability.Temperaturechangesdonotaffectthetightshutoffsincethereisfreedomofmovementbetweentheballandtheseat.Theballcannotbecomewedgedintotheseat.Theguidepinisusedtosetthevalveposition.Duringnormaloperation,ithasnofunction.
Full Open PositionInthefullopenpositionastraight-thruflowpathexistsandthevalveoperateswiththeinherentlyhighflowcapacityofaventuri.Theballisfirmlyheldoutoftheflowstreambyfourinclinedpadsonthecagewhichopposethepres-suredifferentialforce.TheBernoullipressuredifferentialmovesthesuspendedparticlestowardsthecenterofthefluidstream,preventingthemfromsettlingoutintothebody.Thiskeepsthevalvecleanandfreeofmaterialdepositsinallpositionsduringthevalvestroke.
Close Throttling PositionAsthevalveopens,itoperatesintheclosethrottlingposition.Inthisposition,theballissupportedbythetwoforwardinclinedpadsonthecageandtheseatsurfacewhichopposethepressuredifferentialforcecausedbytheBernoullief-fect.Theballissupportedandstablethroughoutthevalvestrokeanddoesnotpinwheelorchatter.
Intermediate Throttling PositionIntheintermediatethrottlingposition,theballrestsonthefourcagepadsandisopposedbythesamedifferentialpressureforce.Thestablesuspensionoftheballthroughoutthevalvestrokepermitsextremelycloseandrepeatablecontrolthroughouttheentirevalvestroke.
DFT® Control Valve Operation
5
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
BernoulliThe Bernoulli Principle Energy per unit volume at inlet = Energy per unit volume at outlet
P1 + 1/2ρv12 + ρgh1 = P2 + 1/2ρv2
2 + ρgh2
Where: P = Pressure Energy; 1/2ρv2 = Kinetic Energy; ρgh1 = Potential Energy
ThebestexampleoftheBernoulliPrincipleisoftencalledthe“BernoulliEffect”whichstatesthatfluidpressuredecreasesasfluidvelocityincreases.
Theillustrationshowsthetypicalchangeinpressureasthefluidmovesthroughthevalve.Atinlet,thepressureisP1.Velocityincreasesthroughthevalvetoamaximumasitmovesthroughthevalveport.Atthevalveport,thepres-suredropstoPVC(pressureatthevenacontracta),whichisthelowestpressureinthevalve.Asthefluidexitsthevalve,pressurerecoverstoP2whichislowerthanP1.
P1
PVC
P2
Cavitation ControlUsingtheillustrationbelow,atP1thefluidstreamisallliquid.Liquidflashesatthevalveportwhenthepressureatthevenacontracta(PVC)dropsbelowtheliquidvaporpressure.Asthevelocitydecreasesintheexitnozzle,thepressureincreases(orrecovers)toP2andthevaporbubblescollapse.Thisisknownasthepotentiallydamagingphenomenacalledcavitation.Unliketortuouspathvalves,ourcontrolvalvesmanagecavitation.Bubblesformatthelowestpressure(highestvelocity)whichisatthecenterofthefluidstream.Thesubsequentcollapseiswithinthehydraulicbarrier,notonmetalsurfaces.Ournozzledesignprovidesasmoothrecoverypriortothefluidexitingthevalve.
P1
PVC
P2
6
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
Nomenclature
HI-100® Control Valve
GUIDERING
PACKING
GLAND
GLANDFOLLOWER
STEM
BONNETBUSHING
BONNET
BONNETSEAL
CAGE
BALL
DOWNSTREAMSEAT
DOWNSTREAMWEARBUSHING
WEARBUSHINGSEAL
SEATSEAL
BODYGUIDEPINSEAL
GUIDEPINCARTRIDGEASSEMBLY
SEATSEAL
WEARBUSHINGSEAL
UPSTREAMSEAT
UPSTREAMWEARBUSHING
FLOW
7
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
• Straight-thru Design- solves your performance problems1. EliminatesDamage:Ouruniquenozzledesignsmoothesturbulencewhicheliminatesbody,trimandpipingdamagecausedbyhighvelocityfluidimpingementinyoursystem.
2. HandlesGreaterFlow:Sincewehavenotortuouspaththroughourvalve,ourvalveshaveahigherCvthanthatofthesamesizevalvemadebycompetitors,oftensavingyoumoney.
3. PrecisionModulation&Control:Our200:1turndownratioandlinearflowcharacteristicgivesyouprecisecontrolovertheentireoperatingrange.
• Unique Trim Design – lowers your cost of ownership1. In-LineRepair:Allstylescanberepairedin-linewithouttheneedforexpensivespecialtoolssavingyoutimeandmoney.
2. LongLife:Ourtrimdesignuseswearcomponentsatthecriticalplacesalongtheflowpathmaximizingdesignlifefortheapplication.
3. LowReplacementCosts:Ouruniqueball,cageandwearbushingdesignallowsyoutheflexibilitytoreplaceonlythewornparts,loweringyourcostofrepairsignificantlywhencomparedtoourcompetition.
• Wide Application Range- can be used in nearly any service1. ANSI150to4500:HandlesallANSIapplications,pressuresupto16,000psiandtemperaturesfrom-425°Fto1900°F.
2. Liquid,Gas,Steam,Slurry:Ournon-tortuouspathdesignhandlesliquids,gases,steam(includingmixedphaseflow),abrasivesandmanyslurryapplications.
3. Materials:StandardbodymaterialsareCarbon,AlloyandStainlessSteel.Highnickelandexoticalloysarealsoavailable–anyweldablealloythatisavailableasaforgedmaterialcanbeused.
• Venturi Nozzle Design – reduces turbulence in your piping system1. CavitationControl:Ournozzledesigncontrolscavitationandreducestheassociatednoiseandvibration.
2. ParticulateandMixedPhaseFlow:Ournozzledesignmovesparticlesandwaterdropletstothemiddleoftheflowstreamavoidingcostlydamage.
3. PreventsErosion:Ournozzledesignsmoothestheflowandreducesthepotentialforvalvebodyandpipeerosion.
• Class V Shutoff
• Actuation Theactuator(Linear:pneumatic,hydraulic,electricetc.)andaccessories(positioners,limitswitches,manualover-rides,etc.)ofyourchoicecanbemountedonthevalve.
Our Unique Venturi-Cage Valve
8
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
ApplicationsAerospace• Air• FuelOil• Gas• HighPressureWaterwithfines• MethaneVapor
Chemical• AbrasiveSlurryControl• HotHydrogenGas• PitchBlendControl• PowerhouseApplications• SuperCriticalWaterOxidation
Government/Military Test• Air• Cryogenic• NitrogenGas• Steam• HighPressureWater
Pulp & Paper• Powerhouse• SteamControl
Power• BottomAsh• CondensateDrain• DrumEmergencyBlowdown
• DrumLevelControl• FeedwaterControl• FeedwaterRecirculation• FuelOilControl• GeothermalWaterInjection
• PowerOperatedRelief• SootBlowerControl• SprayControl(Attemperator,Reheat/Superheat)
• SteamPRV• ThermalDrain• TurbineBypass• TurbineSteamExtraction
Steel• Powerhouse
Refinery• AbrasiveSlurryControl• AmineService• Butadiene• DEA• DesulphurizationSourWater• H2S,NH3,Hydrocarbon• HydrocarbonSluicing• LevelControl• PitchBlendingControl• PlatinumCatalystSlurry• QuenchWatertoCoker• SourWater• SulfurRecoveryThrottlingValve
Pipeline• GasPlantPigging• PipelineControl
Petrochemical• HeavyOilUpgrading
9
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
Codes & StandardsASME B16.5 –PipeFlanges&FlangedFittings
ASME B16.10 –FacetoFace&EndtoEndDimensionsofValves
ASME B16.34–Valves–Flanged,Threaded&WeldingEnds
ANSI/FCI 70-2–ControlValveSeatLeakage–HI-100®&Ultra-Trol®seattest
ANSI/ISA 75.01–FlowEquationsforSizingControlValves
ANSI/ISA 75.08.01 Face-to-FaceDimensionsforFlangedGlobe-StyleControlValve Bodies-LSV-100®
API 598–ValveInspection&Testing–Uniflo®seattest
MSS-SP 25–StandardMarkingSystemforValves,Fittings,Flanges&Unions
Sizing DFT® Control ValvesDFT®ControlValvesaresizedusingstandardISAsizingformulaeforliquid,gasandsteamapplications.
PleasecompletetheApplicationDataSheetonpage10sothatwecanspecifythepropervalveforyourapplication.AdditionalinformationconcerninganyvalvethatisbeingreplacedbyourvalvesuchastheCvofthatvalveandtheoriginaldatasheetcanbeusedtoeffectivelyspecifythepropervalveaswell.
AccessoriesThefollowingaccessoriesareavailablefortheDFT®ControlValves
ACTUATORS ACTUATOR ACCESSORIES PACKING SPECIAL TRIMPneumatic Diaphragm Air Filter Regulator Graphite Feedwater
Pneumatic Piston Air Set Teflon® (CVH) Steam
Electric Limit Switches Live Loaded Catalyst
Electro-Hydraulic Manual Override Emission Compliant Slurry
Hydraulic Positioner
Manual Solenoid
Transducer
10
140 Sheree Blvd.P O Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
Process Data
2 ApplicationMin Normal Max Units
22 TemperatureFluid properties (if known) Units
ytisocsiV72yrtnE1112 Orientation
Valve Design Conditions Units28 Pressure29 Temperature
Process Notes
15 Seals
16.1 Air 34 PositionerSignal
16.2 Electric 35 Solenoid Type/Model/Voltage36 Limitswitch Quantity/Location
16.3 Hydraulic *Notes Type/Model/Voltagepsig
38 Gages16.4 Manual 39 Special
Notes
d ma ks of FT®
Digital/EP/Type
Actuator Accessories
Size/scheduleSize/schedule
Packing
Valve Type
Actuator
CUSTOMER:ADDRESS:
FAX:CONTACT:
EMAIL:
General
Trim
PHONE:
14
® FAX OR SCAN AND EMAIL THIS COMPLETED FORM TO THE FACTORY
11
140 Sheree Blvd.P.O. Box 566Exton, PA 19341-0566
e-mail: dft@dft-valves.com
internet: www.dft-valves.com
610-363-8903800-206-4013FAX 610-524-9242
®
DFT® ULTRA-TROL®TheDFTULTRA-TROL®ControlValvefeatureshardenedsleevesforslurryapplications.Thisstylevalveisdesignedforflangedendapplicationsandbenchreplacementoftheseatinsert.Theinternaldesignisthesamein-lineventuriflowdesignusedfortheHI-100®.Thecontrolelement,asphericalball,iscontainedbyacagewhichpositionsitrelativetothedownstreamseat.Stemtravelislinearandoperatingthrustsarelow.Theresultisexcellentcontrolintoughenvironments.Theball,cageandstemcanbereplacedin-linethroughthebottomcover.
• Straight-thrudesign• 1/2”to6”• CarbonSteel,AlloySteelStainlessandHighAlloys• ANSIRF,RTJorDINEnds• LinearCharacteristic• HardenedSleeves• Temperatures:-425°Fto1000°F• BenchRepair• Manual,Pneumatic,or Electric• LowOperatingThrust• BottomEntry
FEATURES:
Ultra-Trol Maximum Flow CoefficientSizeNPS 1/2 3/4 1 11/4 11/2 2 2.5 3 4 6
SizeDN 15 20 25 32 40 50 65 80 100 150
Cv(Kv) 4.5(3.9) 10(8.6) 20(17) 31(27) 45(39) 80(69) 125(108) 180(155) 320(275) 720(621)
Ball
Upstream Seat Liner
CageGuidePin
DownstreamSeatLiner
REPRESENTED BY
EachDFT®Inc.product iswarrantedagainstdefects inmaterialandworkmanshipforaperiodofoneyearafterbeingplacedinservice,butnotexceeding18monthsaftershipment,whentheseproductsareproperlyinstalled,maintainedandusedwithintheserviceandtemperatureandpressurerangesforwhichtheyweredesignedandmanufactured,andprovidedtheyhavenotbeensubjecttoaccident,negligence,alteration,abuse,misuseorthelike.Thiswarrantyextendstothefirstpurchaseronly.Alldefectivematerialmustbereturnedtothepersonfromwhomyoupurchasedtheproduct,transportationprepaid,freeofanyliensorencumbrancesandiffoundtobedefectivewillberepairedfreeofchargeorreplaced,atthewarrantor’sorDFT’soption.FORACOMPLETEUNDERSTANDINGOFYOURSOLEANDEXCLUSIVELEGALRIGHTSANDREMEDIES,ANDTHEPROCEDURESTOBEFOLLOWEDWITHRESPECTTOANYCLAIMS,PLEASEREFERTOTHE“LIMITATIONANDDISCLAIMEROFWARRANTIESANDLIABILITIES,”AVAILABLEONREQUESTFROM DFT. THE EXPRESS WARRANTIES SET FORTH IN THAT DOCUMENT AND THE OBLIGATIONS AND LIABILITIES OF DFT THEREUNDER AREEXCLUSIVEANDAREEXPRESSLYINLIEUOFALLOTHERWARRANTIES,EXPRESSORIMPLIED,INCLUDINGWITHOUTLIMITATION,THEWARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE,ANDALLOTHEROBLIGATIONSANDLIABILITIESOFDFT. IT ISUNDERSTOODTHATTHEREARENOWARRANTIESWHICHEXTENDBEYONDTHEDESCRIPTIONOFTHEEXPRESSTERMSINTHE“LIMITATIONANDDISCLAIMEROFWARRANTIESANDLIABILITIES.”UNDERNOCIRCUMSTANCESSHALLDFTBELIABLEFORANYCONSEQUENTIAL,INCIDENTAL,ECONOMICAL,DIRECT,INDIRECT,GENERALORSPECIALDAMAGES,EXPENSESORLOSSESRELATINGTOANYBREACHOFWARRANTIES.Itisexpresslyunderstoodandagreedthatunlessastatementisspecificallyidentifiedinthisbrochureasawarranty,thestatementsmadehereinrelatingtoDFT’sproductsarenotexpresswarranties,butaremerelyforinformational,illustrativeandidentificationpurposesonly.
Warranty
Benefits of DFT® Control ValvesCompact Size & Straight-thru Design • Easiertoinstall • Designprovidessmoothflowtransitionsthroughvalvebecausefluiddoesnothavemultiplerightangleturns.
• Astraightthroughflowpathislessturbulentanditwillnotclogfromsolidparticles.Italsoleadstonon-turbulentpressurerecovery.
Modulating Control• Designoffersbettermodulatingcontrolthananyothercontrolvalveonthemarkettoday.
High Flow Capacity and Larger Cv’s • 2-3timestheflowcapacityofnominalsizecontrolvalves.
Low Leakage and Tight Metal-to-Metal Sealing •PerAPI598and/orFCI70-2ClassV
Low Cost of Spare Parts and Quick Change Trim• TheDFTHI-100isserviceablein-linewithoutspecialtools.A1”valvecanbeservicedinlessthan2hours.
Low Actuator Cost • DFTHI-100isposition-seateddesign.Globevalvesareforceseated.Therefore,lessactuatorforcesarerequiredtooperatevalveandthereforeallowstheuseofsmaller,lessexpensiveactuatorpackages.
Prevents sediment build-up with Self-purging Design • Duetotheventuriflowpathandresultingincreaseinvelocity,thebodycavitiesarepurgedpreventingsedimentbuildupwithinvalvebody.Thisoccursduetoavacuumingeffect.
Printed in U.S.A. Copyright2016,DFT Inc.,All RightsReserved HI-100Rev.01-2016
®