commissioning for digital tv transmitter
Post on 01-Nov-2014
44 Views
Preview:
TRANSCRIPT
Commissioning for Digital TV TransmitterDigital TV Transmitter
Bimbingan TeknisPetugas Pengendali Frekuensi Radio
Batam, 21 Juni 2011
TRANSMITTER
SITE : TVRI BATAM
POWER : 2 kWatt ( RMS )
STOCK NO : NV8604V 2076. 9301. 61
SERIAL NO : 101 239 - VX SERIAL NO : 101 239 - VX
FREQUENCY : CHANNEL 40 ( 626 MHz )
MEASURING INSTRUMENTS
1. TV Analyzer: ETL 2112.0004.K13.
S/N:102064
2. Power Meter: NRVS 1020.1809.02 S/N:864
296/006 296/006
3. Diode Power Sensor: NRV - Z4 828.3618.03.
S/N : 100 009
• DATE: 1-Dec-2010
• Test & Commissioning by : Witnessed by :
Before Bandpass Filter :
1. Output Power Measuring :
• 1.1 Coupling Attenuation : 59 dB
• 1.2 CCU Read Out : 2010 W 2010 W • 1.2 CCU Read Out : 2010 W 2010 W
• 1.3 Actual Power : 2050 W 2050W
• 1.4 Nominal Power : 2000 W 2000 W
2. Transmission Quality :
Exciter A Exciter B
Harmonic Emission
Spurious Signals
3. Over View ( Summary ) :
4. Modulation Analysis :
Exciter A Exciter B
Constellation Diagram
MER
CCDF
I / Q Imbalance
5. Channel Analysis :
Exciter A Exciter B
Amplitude & Phase
Amplitude & Group Delay
6. Spectrum :
Exciter A Exciter B
Shoulder Attenuation
Out Band of Emission
After Bandpass Filter :
1. Output Power Measuring :
• 1.1 Coupling Attenuation : 59 dB
• 1.2 CCU Read Out : 2010 W 2010 W • 1.2 CCU Read Out : 2010 W 2010 W
• 1.3 Actual Power : 1870 W 1870 W
• 1.4 Nominal Power : 2000 W 2000 W
2. Transmission Quality :
Exciter A Exciter B
Harmonic Emission
Spurious Signals
3. Over View ( Summary ) :
4. Modulation Analysis :
Exciter A Exciter B
Constellation Diagram
MER
CCDF
I / Q Imbalance
5. Channel Analysis :
Exciter A Exciter B
Amplitude & Phase
Amplitude & Group Delay
6. Spectrum :
Exciter A Exciter B
Shoulder Attenuation
Out Band of Emision
Terima
KasihKasih
top related