AERIAL BUNDLED CABLE (ABC) - LOW VOLTAGE (LV)
1
0.6/1(1.2) KV AL - Aerial Bundled Cable for Overhead Distribution Lines.IEC 60228, IEC 60811, BS 2627, IEC 60502-1 : 2004
S/N Cable SizeStandard Packing Street Lighting
Length(m)
Weight(kg)
No.ofstrands
Diameter(mm)
Cross-section
area(mm2)
Max.conductor
resistance at20ºC deg(ohm/km)
No.ofstrands
Diameter(mm)
Cross-section
area(mm2)
Max.conductor
resistance at20ºC deg(ohm/km)
No.ofstrands
Diameter(mm)
Cross-section
area(mm2)
Max.conductor
resistance at20ºC deg(ohm/km)
11 x 16mm2 + 1 x25mm2
1000 170 7 4.9 16 1.91 7 6.0 25 1.312 - - - - 55
23 x 16mm2 + 1 x25mm2
1000 285 7 4.9 16 1.91 7 6.0 25 1.312 - - - - 50
33 x 35mm2 + 1 x25mm2
1000 500 7 7.0 35 0.868 7 5.9 25 1.312 - - - - 123
43 x 50mm2 + 1 x35mm2
1000 680 7 8.4 50 0.641 7 7.0 35 0.99 - - - - 147
53 x 70mm2 + 1 x50mm2
1000 940 19 9.9 70 0.443 7 8.4 50 0.69 - - - - 164
63 x 95mm2 + 1 x70mm2 + 1 x16mm2
500 848 19 11.7 95 0.320 19 9.9 70 0.469 7 4.9 16 1.91 189
73 x 185mm2 + 1 x120mm2 + 1 x16mm2
500 1540 37 16.2 185 0.164 19 13.0 120 0.273 7 4.9 16 1.91 279
Phase Conductor Messenger/Suspension Unit Continuouscurrentrating at
30ºCambienttemp (A)
Central Cables Berhad
AERIAL BUNDLED CABLE (ABC)- MEDIUM VOLTAGE (MV)
2
6.35/11kV AL - Aerial Bundled Cable for Overhead Distribution Lines.IEC 60502-2: 2005
No. ofstrands
WireDiameter
(mm)
Nominalcross-section
area(mm2)
Maxconductor
resistance at20ºC
No. ofstrands
WireDiameter
(mm)
Nominalcross-section
area(mm2)
BreakingLoad(kN)
2 3C x 70mm2 +1C x 50mm2 19 2.14 70 0.443 7 3.15 50 62 210
3 3C x 95mm2 +1C x 50mm2 19 2.52 95 0.320 7 3.00 50 60 173
4 3C x 185mm2 +1C x 120mm2 37 2.52 185 0.164 7 4.67 120 150 259
5 3C x 150mm2 +1C x 50mm2 37 2.25 150 0.206 7 3.15 50 62 365
6 3C x 240mm2 +1C x 50mm2 61 2.25 240 0.125 7 3.15 50 62 500
Continuouscurrentrating
at30ºC
ambienttemp (A)
S/N Cable Size Phase Conductor Messenger/Suspension Unit
1 3C x 50mm2 +1C x 25mm2 19 1.78 50 0.641 7 3.00 50 60 116
Central Cables Berhad
AERIAL BUNDLED CABLE (ABC)MEDIUM VOLTAGE (MV)
3
19/33kV AL - Aerial Bundled Cable for Overhead Distribution Lines.IEC 60502-2: 2005
No. ofstrands
WireDiameter
(mm)
Nominalcross-section
area(mm2)
Maxconductor
resistance at20ºC
No. ofstrands
WireDiameter
(mm)
Nominalcross-section
area(mm2)
BreakingLoad(kN)
Continuouscurrentrating
at30ºC
ambienttemp (A)
S/N Cable Size Phase Conductor Messenger/Suspension Unit
1 3C x 50mm2 +1C x 50mm2 19 1.78 50 0.641 7 3.00 50 60 165
3 3C x 185mm2 +1C x 70mm2 37 2.52 185 0.164 7 3.57 70 91 355
4 3C x 70mm2 +1C x 50mm2 19 2.14 70 0.443 7 3.15 50 62 250
2 3C x 150mm2 +1C x 50mm2 37 2.25 150 0.206 7 3.00 50 60 315
5 3C x 150mm2 +1C x 50mm2 37 2.25 150 0.206 7 3.15 50 62 370
Central Cables Berhad
AERIAL BUNDLED CABLE (ABC)- MEDIUM VOLTAGE (MV)
Cross Section of Medium Voltage Aerial Bundled Cable
No. Description 1
2
3
4
5
6
7
8
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Binder
Outer Sheath
Messenger
1
2
3
4
5
6
7
8
4
Central Cables Berhad
BARE ALUMINIUM CONDUCTOR
5
Stranded Aluminium ConductorStranded Multi Wires To BS 6360:1991
Size of ConductorNominal cross
sectional area ofconductor
No. & sizeof wire
Nominal diameterof conductor
Maximumresistance at
20ºCApprox.mass
mm2 No./mm mm kg/km
4610162535507095120
1501852403004005006308001000
7/0.857/1.047/1.357/1.7019/1.3519/1.5319/1.7819/2.1419/2.5237/2.03
37/2.2537/2.5261/2.2561/2.5261/2.8561/3.2061/3.63127/2.85127/3.20
2.553.124.055.106.427.658.9010.7012.6014.21
15.7517.6420.2522.6825.6528.8032.7637.0541.60
7.414.613.081.911.200.8680.6410.4430.3200.253
0.2060.1640.1250.1000.07780.06050.04690.03670.0291
10.1016.0027.0042.2069.5094.1012.58183.00255.18323.36
405.30500.00648.10810.101073.001350.001701.892162.002703.00
Central Cables Berhad
ALL ALUMINIUM CONDUCTOR (AAC)
Standard Sizes of All Aluminium Conductors for Overhead PowerTransmission
ConductorNominal
crosssectional area of
conductor
mm2
Equivalentcopperarea
Construction
No. / wirediameter
Approx.overall
diameter
Calculatedbreaking
load
CalculatedD.C
resistanceat 20ºC
Approx.Net
Weight
CodeName
mm2 mm2 mm kN kg/km
22
50
60
100
150
200
250
300
400
14.2
32.2
38.78
64.7
96
130
162
197
253
7/2.06
7/3.10
7/3.40
7/4.39
19/3.25
19/3.78
19/4.22
19/4.65
37/3.78
6.18
9.30
10.20
13.17
16.25
18.90
21.10
23.25
26.46
3.99
8.28
9.90
16.00
24.70
32.40
40.40
48.75
63.10
1.227
0.5419
0.4505
0.2702
0.1825
0.1349
0.10830
0.08916
0.06944
64
144
175
291
435
586
730
886
1143
Midge
Ant
Fly
Wasp
Hornet
Chafer
Cockroach
Centipede
6
Central Cables Berhad
Stranded Hard - Drawn All AluminiumConductor (AAC)
7
Nominal
crosssectional area of
conductor
ConstructionNo. / wirediameter
Calculatedarea
Approx.overall
diameter
Approx.net
weight
Minimumbreaking
load
CalculatedDC
resistanceat 20ºC
Hard-drawncopper
equivalentarea
mm2 No./mm mm2 mm kg/km kgf mm2
30
38
55
95
150
200
240
300
400
510
660
850
980
1260
7/2.3
7/2.6
7/3.2
7/4.2
19/3.2
19/3.7
19.4.0
37/3.2
37/3.7
37/4.2
61/3.7
61/4.2
91/3.7
91/4.2
29.09
37.16
56.29
96.95
152.8
204.3
238.8
297.6
397.8
512.5
655.8
844.9
978.3
1260
6.9
7.8
9.6
12.6
16.0
18.5
20.0
22.4
25.9
29.4
33.3
37.8
40.7
46.2
80
102
154
265
419
560
645
820
1090
1410
1820
2330
2710
3500
469
575
838
1410
2270
3030
3490
4430
5890
7460
9720
12300
14500
18350
0.983
0.769
0.507
0.295
0.188
0.140
0.120
0.0969
0.0726
0.0563
0.0441
0.0342
0.0297
0.0230
12.62
23.34
35.35
60.88
95.96
128.3
150.0
186.9
249.8
321.9
411.8
530.6
614.4
791.3
Central Cables Berhad
All Aluminium Alloy Conductor (AAAC)
Standard Sizes of All Aluminium Conductors for Overhead PowerTransmission
ConductorNominal
crosssectional area of
conductor
mm2
Equivalentcopperarea
Construction
No. / wirediameter
Approx.overall
diameter
Calculatedbreaking
load
CalculatedD.C
resistanceat 20ºC
Approx.Net
WeightCodeName
mm2 No./mm mm kN kg/km
25
30
40
50
100
150
175
300
16.2
19.1
25.8
32.3
64.5
97
113
194
7/2.34
7/2.54
7/2.95
7/3.30
7/4.65
19/3.48
19/3.76
37/3.53
7.02
7.62
8.85
9.90
13.95
17.40
18.80
24.71
8.44
9.94
33.30
50.65
59.10
101.50
13.4
16.80
1.094
0.9281
0.6880
0.5498
0.2769
0.1830
0.1568
0.09155
81
98
130
165
137
495
578
995
Almond
Caedar
Fir
Hazel
Oak
Ash
Elm
Upas
8
Central Cables Berhad
Bare All Aluminium Alloy Conductor (AAAC)
9
Aluminium alloy (AAAC) contains a small percentage (about 0.6%) of silicon and magnesium elements. It
(i) Strength : About twice that of aluminium 1350 (EC).
(ii) Weight : 20% (approx.) lighter than ACSR conductor of equal diameter.
(iii) Corrosion resistance : It has a high resistance to atmospheric corrosion which is suitable for coastal and indusrial areas.
liable to damage during installation which is an important advantage of EHV transmission lines where corona and radio interference is a major consideration.
(v) Termination : Much simpler jointing accessories required compared to ACSR.
(vi) AC Resistance : AAAC is an non-magnetic material. It does not exhibit the magnetic core losses found in ACSR conductor
7(1 + 6) 19(1 + 6 + 12) 37(1 + 6 +12 + 18)
6(1 + 6 + 12 + 18 + 24) 91(1 + 6 + 12 + 18 + 24 + 30) 127(1 + 6 + 12 + 18 + 24 + 30 + 36)
Central Cables Berhad
Aluminium Conductor Steel Reinforced (ACSR)
Standard Sizes of All Aluminium Conductors Steel Reinforced for OverheadPower Transmission.
Conductor
Nominal Al.
area
Equivalentcopperarea
ActualSectional
Construction
No./ Size of Wire
Approx.overall
diameter
Calculatedbreaking
load
CalculatedD.C
resistanceat 20ºC
Approx.Weight
CodeNameAI Steel
AI. Steel AI. Steel
mm2 mm2 mm2 mm2 No./mm No./mm mm kN ohm/km kg/km kg/km
25
30
40
50
*60
70
100
150
150
175
175
200
200
*300
400
16.0
19.3
25.8
32.3
38.6
44.8
64.0
96.4
96.8
111.9
112.4
129.0
128.0
197.0
262.0
26.25
31.61
42.41
52.88
63.22
73.37
105.0
158.1
158.7
183.4
184.3
212.1
210.6
323.0
428.9
4.37
5.27
7.07
8.81
36.88
42.8
13.5
36.8
8.8
42.8
10.2
49.5
11.7
15.5
55.6
6/2.36
6/2.59
6/3.00
6/3.35
12/2.59
12/2.79
6/4.72
30/2.59
18/3.35
30/2.79
18/3.61
30/3.00
18/3.86
18/4.78
54/3.18
1/2.36
1/2.59
1/3.00
1/3.35
7/2.59
7/2.79
7/1.57
7/2.59
1/3.35
7/2.79
1/3.61
7/3.00
1/3.86
7/1.68
7/3.18
7.08
7.77
9.00
10.05
12.95
13.95
14.15
18.13
16.75
19.53
18.05
21.00
19.30
24.16
28.62
9.61
11.45
15.20
18.35
52.94
61.20
32.70
69.20
35.70
79.80
41.10
92.25
46.55
69.67
131.90
1.093
0.9077
0.6766
0.5426
0.4566
0.3936
0.2733
0.1828
0.1815
0.1576
0.1563
0.1363
0.13670
0.08914
0.06740
72
87
117
145
175
203
288
437
437
507
507
586
580
887
1186
34
41
55
69
289
335
106
289
69
335
81
388
91
123
435
Gopher
Weasel
Ferret
Rabbit
Skunk
Horse
Dog
Wolf
Dingo
Lynx
Caracal
Panther
Jaguar
Batang
Zebra
Note: 1) *Not a standard Size in BS 215 : Part 2.
ACSR is a composite, concentrically stranded conductor in which the light weight and good conductivity
of aluminium are combined with the high tensile strength of steel. It is composed of one or more layers
of EC grad hard-drawn aluminium wires helically stranded around an inner core of high strength zinc-
coated steel wires. The inner steel core may be a single zinc coated steel wire, or concentrically stranded
of one or more layer of zinc-coated steel wires.
ACSR has long been widely used as overhead high tension transmission lines and has an established
reputation for economy and dependability. The illustrarion below shows typical standard sizes and
stranding patterns.10
Central Cables Berhad
Bare Aluminium Conductor Steel Reinforced(ACSR)
11
6 + 1 6 + 7(1 + 6) 12 + 7(1 + 6) 14 + 7(1 + 6) 14 + 19(1 + 6 + 12)
18(6 + 12) + 1 24(9 + 15) + 7(1 + 6) 26(10 + 16) + 7(1 + 6) 30(12 + 18) + 7(1 + 6)
45(9 + 15 + 21) + 7(1 + 6) 48(10 + 16 + 22) + 7(1 + 6) 58(12 + 18 + 24) + 7(1 + 6) 30 (12 + 18) + 19(1 + 6 + 12)
54(12 + 18 + 24) + 19(1 + 6 + 12) 72(9 + 15 + 21 + 27) + 7 (1 + 6) 84(12 + 18 + 24 + 30) + 19(1 + 6 +12)
Central Cables Berhad
LOW LOSS CONDUCTORTHERMAL ALUMINIUM ALLOY CONDUCTOR STEEL REINFORCED
(STEEL ALUMINIUM CLAD) / TRAPEZOIDAL SHAPED WIRE (TACSR(SA)/TW)
12