The CCUNet range of products, when integrated with XL Graphics, provide fire network amalgamation for various differing fire networks. Rapid and effective monitoring and control is provided via multi-drop secure terminals.
CCUNet is a multi-point, point to point network, meaning that different data can be simultaneously transmitted between points on the network. The network is designed in a way such that all network segments transmit and receive imultaneously - greatly increasing the capacity of the network. Each CCUNet node has routing and packet processing capability. This allows:– Network segment failure isolation– Fast data transfer via routing tables– Multi-star and multi-loop support
Features
// Reliable, compact communication devices used to connec Fire Networks to the CCUNet// Implement CCUNet data transportation via numerous data-link protocols including •RS485 •RS422 •RS232 •Fibre(Single&MultiMode) •Ethernet(TCP/IP) •Modem// Available in robust enclosure configurations for easy mounting
System features
// FirenetworkssupportedincludeVigilant,Simplex,MXand otherCollectiveFIPsviahardcontact// ConnectsmultipleFIPsandothersupporteddevicestoa centralCommandCentre(XLGraphics)// MultipleXLGraphicssystemscanbeconnectedandco figured for local or global system annunciation and control as required// Providessystemwidecontrolandannunciationofmultiple fire protection systems// CCUNet implements dual redundant communication loops for transparent information routing around breakages and failures in the network
Safer. Smarter. Tyco.™
CCU Family of Modules
CCU Family of Modules
Product DescriptionTheCCU3isahighquality,highendcommunicationnetworkproductthatmaybeusedinLifeSafetysystems.SeveralisolatedcommunicationportsarecapableofimplementingvariouscommunicationDataLinkLayerprotocols.It has a supervised input for network alarm annunciation even in theeventofCCU3softwareand/orprocessorfailure.
Product BackgroundThe CCU range of products have been developed over many years and are in use in a wide variety of applications within a largenumberofsites.Primarilytheyareusedfornetworkingoffirepanels,normallytoone(ormore)centralisedlocations.Asa secondary function, they are well suited as interfacing points for a wide variety of third party equipment and protocols. The existingCCUhardwareproducts(CCU1,CCU2)canbedescribedas individual hardware boards which satisfy each physical protocol. The CCU range of products are suited to star, ring and combinatorialtopologynetworks.TheCCU3unitestheindividualfeaturesoftheCCU1andCCU2intoonesuperiorlifesafety communication product.
Feature Advantage Benefit
OneadditionalCCUNetPort Fewer CCU boards are requiredinSTARandHUBnetworkconfigurations
Overall reduced capital cost on large and/orcomplexlifesafetynetworks
CommonbaseCCUboardformixednetwork topologies such as copper, fibre,
modem
Fewer spares are required to maintain entire network
Reducedexpenditureonholdingspares
FireAlarmannunciationtoadjacentFIPevenwhenlocalCCUCPUand/or
software has failed
Generalalarmsignalforbuilding/FIPwill still be annunciated until fault can be
rectified
Emergency personnel and equipment can still be directed to location of fire despite
there being a serious monitoring failure
Widetemperaturerange(-40°Cto+80°C Suitableformilitaryandmarineapplications
Largermarketforspecialand/orcustomuser requirements plus increased
reliability at commercial temperatures
Unique embedded hardware ID Unprogrammed boards can be automatically detected on the network
Lesstimerequiredfornetworkconfiguration and/or fault finding
Compartmentalised hardware design Failure of hardware can be isolated toadiscretesectionoftheCCU3
CCU3maystilloperateaslifesafetynetwork node albeit at a reduce capability
Advanced Internal Diagnostics DifferentsectionsofCCU3arecontinuously monitored for changes in
power and temperature
Speedydetectionofpotentialnetworknode failure
ExpansionConnector Additional interfaces, protocols and standards are and will be supported utilisingCCU3expansionboards
Communication standards and speeds are progressing rapidly. Customers’ initial
investment is protected because future interface boards can be used for
compliance and upgrade
Approvals ULandENapproved ComplieswithstringentULandENstandards
CCU1
CCU2
CCU3
CCU Family of Modules
Technical Communications // 4isolatedCOMMports// EachCOMMportisindividuallysoftwareconfigurabletouseeitherRS232,RS422 orRS485communications// EachCOMMporthasgreentransmitandyellowfaultLEDs
Output Relay // AnElectricallyProgrammedLogicDevice(EPLD)controlledrelayoutput andrelayLEDisavailable.It’sconfigurableandcanbeusedtoindicate processor or comm failure, alarm annunciation or control via CCUNet combinatorial logic. // TherelayLEDisEPLDcontrolledandsomayalsobeusedasaseparate visual indicator
Supervised Input// ASupervisedAlarminputhasbeenprovided 0mA-5mA –SupervisionFailure 5mA-10mA –SupervisedNormal >10mA –Active/Alrm >40mA –CurrentLimited
Expansion ConnectorTheCCU3hasprovisionforexpansionmoduleswhichcanbefittedtothetopofthebaseunit. Up to four modules can be fitted simultaneously.
RS422
RS232
RS485
Relay Output
SupervisedInput
CCU Family of Modules
Environmental// Robust metal enclosure// Temperaturerating:-40°Cto+80°C// MTBF>950000hours
DIP Switches// PLDReprogram –Enableswitch// Redundancy Test – Board self test of redundant alarm signalling capability// Watchdog Enable – switch for secondary hardware watchdog
Indicators// LEDindicationforCCUstatusandmaintenanceincluding:// Powertocircuitry// Excesspowerconsumption// Communication failure// EarthLoopfault// Relay mode and status indication// Powersupplytemperature
Power// CCU3canbepoweredfromasourcerangeof11.5-16Vdcor18-30Vdc. Ideallya12Vdcor24Vdcsource.CCU3consumesamaxof5W
Vdc 11.5-16Vdc&18-30Vdc
CCU Family of Modules
Expansion ModulesInput/OutputTheexpansionboardadds10supervisedinputsand4outputstothe CCUNet.
WirelessTheGSMexpansionboardcurrentlysupportsdualband,withtri-bandsupportinthenearfuture.PrimarilyitisusedasadatainterfacetoCCU3(eg.pagingapplicationtomobilephones).Italsohasthecapabilitytointerfacetoexternalvoiceinputandoutput which could be used for voice evacuation and/or security applications.
ModernCapable of operating in leased-line mode for point to point operation of CCUNet via unpowered telephone lines and in power-linemodeforoperationoverthecarriernetwork(eg.PSTN).
EthernetSupportsconnectionoftheCCUNettoaTCP/IPnetwork
Fibre OpticConsistsofanumberofexpansionboardstosatisfyabroadrange of fibre types and interfaces. The fibre boards support the CCUNethighspeednetworkingcapability(1300nmMultiMode,1300nmSingleMode,820nm).
PBX
Leased Line
TCP/IP
Fibre
CCU Family of Modules
High Speed NetworkingThe communications sub systems are designed to support simultaneous operation of network communication ports at high speed. This will enable the transmission of multi channel digital voice and video via the CCUNet.
Redundant Power SupplyUsedasabackupincaseoffailureoftheprimaryCCU3powersupply.
PrimaryPower
BackupPower
MXPanel
MXNetwork
MXPanel TLI800
LAN
MXPanelTLI800
TLI800
CCU3/4100CCU3/F
CCU3/TPICCU3/C-HUB
CCU3/4100CCU3/F
CCUNetCCU3/C-HUBCCU3/F
RS232Dongle
LXG&/orOPCServer
LXGClient
CCU3/C-TPICCU3/E
Typical ApplicationsUniversityExample–CCUNet loop configurationExistingMX,VigilantandSimplexfirenetworks,locatedinthe Administration and Chemistry buildings, were previously supervised separately via their own terminals housed in their respectivebuildings.ConventionalFIPsarealsolocatedintheSquashCourtsComplex.TheArtsbuildingistobesupervisedusinganewSimplexnetwork.
UtilisingCCU3/TPI,CCU3/4100,CCU3/CISIBandCCU3/IOdevices,theMX,SimplexandVigilantnetworksaswellasConventionalFIPsareattachedtotheCCUNet.
CCU3/HUBdevicesareusedtoprovideaccesstothreeindividualXLGraphicsterminalslocatedwithineachbuildingforcontrolandmonitoring of their respective building. This is an optional addition. AfourthCCU3/HUBconnectsaGlobalXLGraphicsterminaltothe CCUNet. This terminal is configured to control and monitor theentiresystem.ACCU3/M-PAGERunitannunciateseventstoFireandSecuritypersonnel.Finally,twoCCU3/C-RDMunitsareused to provide secure remote access to the CCUNet network for aRemoteGraphicsTerminal.CCUNetInterfaceDevicessupportdynamic third party fire network configurations.
Example1hasCCUNetinterfacedevicesconnectingdissimilarfirenetworkstotheCCUNet
(1loop).
Example2usesthesameinterfacedevicestoconnectindividualFIPstotheCCUNet(2loops).
CCU Family of Modules
XLGand/orOPCServer
CCU3/C-TPI
RS232Dongle
TLI800
MXPanel
CCUNet Topologies
XLGand/orOPCServer
CCU3/C-TPICCU3/E
RS232Dongle
TLI800
MXPanel
LAN
CCU3/C-TPICCU3/E
XLGand/orOPCServer
CCU3/C-TPICCU3/F
RS232Dongle
TLI800
MXPanelCCU3/C-HUBCCU3/F
2xFibresSingleorMulti-mode
MODUSMasterTLI800MXPanel CCU3/C-MXMB
RS232
MODUBUS
CCUNet over Fibre
TCP/IP Connection
Direct Connection
CCU Family of Modules
ThisExamplehasCCUNetinterfacedevices connecting dissimilar fire networks to the CCUNet .
University ExamplesCCNet Interface Devices supports dynamic third party fire network configuration
CCU3/M-PAGER(422)
Fire&SecurityCentre
GlobalGraphics
CampusTCP/IPLANorWAN
Engineering&Maintenance Graphics
CCU3/C-HUB(422)
CCU3/E-HUB(422)
CCU3/C-IO(422)
CCU3/C-IO(422)
CCU3/C-4100(422)
CCU3/C-4100(422)
Chemistry Building
TLI800TLI800
AdministrationBuilding
CCU3/C-4100(422)
SimplexPanels
CollectivePanels
Remote Access off-Campus
CCU3/M-RDM(422)CCU3/M-RDM(422)
SquashCourts
ARTSBuilding
CCU Family of Modules
TLI800
TycoMXPanelsTLI800
CCU3/F-HUB
AdministrationBuilding
TycoMXPanels
TLI800
TLI800
CCU3/FST-TPI(422)
CCU3/C4-TPI(422)
CCU3/C4-TPI(422)
CCU3/F-HUB
GraphicsWorkstation
Arts Building
CCU3/C-4100(422)
CCU3/C-4100(422)
SimplexPanels
CCU3/C-IO(422)
CCU3/M-RDM(422)
CCU3/C-IO(422)SquashCourts
Remote Access off-Campus
Remote Graphics
PSTNCCU3/M-RDM(422)
CCU3/M-RDM(422)
CollectivePanels
CCU3/E-HUB(422)
Engineering&Maintenance Graphics
GlobalGraphics
CCU3/CHUB(422)
CampusTCP/IPLANor WAN
CCU3/M-PAGER(422)
CCUNetRS422RedundantLoop
This example uses the same interface devices to connect individual FIPs to the CCUNet (2 loops).
ZETTLER,isaleadingbrandoffiredetection,security,andcarecommunicationsproductsintheEuropeanmarket.TheZETTLERfiredetectionproductlineincludesawiderangeMZXTECHNOLOGYEN54CPDapprovedfiredetectionproductscarryingapprovalsandcross-listings,includingVdSandNF,forallEuropeancountries.TheZETTLERcarecommunicationsproductlineisatechnologyleaderprovidingthelatestIPbasedNursecall,EmergencyCall,CommunicationandManagementsolutionsforcarehomes,hospitals,prisons,andrelatedmarkets.TheZETTLERproductlinesareavailablethroughZETTLERdealersaswellasmanyADTandTycoofficesaroundtheworld.Formoreinformation,visitwww.zettlerfire.com.
PSF228ZT-November2012
CCU Family of Modules
Safer. Smarter. Tyco.™
OperationXL Graphics Command Centre Terminals can annunciate events - such as alarms, circuits/points, supervisories,faults,disarmeddevices-foreveryFIPviatheCCUNet.EachXLGraphicsterminalhastheabilitytocontrolanyFIPconnectedtotheCCUNet.Forexample,anXLGraphicsterminal can: acknowledge events, disarm devices, reset, initiate diagnostic testing - subject to the connected c.i.e.
Fire Network Event annunciation information from the fire panels is routed via direct pathsthroughtheCCUNet.TheXLGraphicsTerminalactsonthe first event to arrive, discarding any subsequent duplicate eventpackets.Undernormaloperation,XLGraphicswillreceivetheeventmessagefrom2paths.Thisensuresthatintheeventofafatalnetworkerror(cablebreak),oranonfatalerror(packetcorrupted),eventannunciationisnotinanywayaffectedorpostponed.
A Single Operator atanyXLGraphicsCommandCentreTerminallocation,cancontrol and monitor any device or module on the entire network (subjecttothesupportofthec.i.e.connected).
CCUNet FIP connectionssupportbothhighlevel(software)andlowlevel(printerportorhardcontacts).communicationsThisensuresXLGraphicsprovidesthefullrangeofFIPmonitoringandcontrolfunctionality.
Vigilant ZettlerSimplex MODBUSTycoMX DialUpandDirectConnectPagers
StandardsAustralia C-Tick-AS/NZS4251.2:1999
EuropeEN6100-4-2ElectrostaticDischargeEN6100-4-3RadiatedFieldImmunityEN6100-4-4FastTransientprotectionEN6100-4-5ElectricalSurgesClass5EN50081-2EMC
VIGILANT,SIMPLEX,TYCOareregisteredtrademarksoftheirrespective organisations. At the time of publishing some expansionmodulesandapprovalsmaynotbeavailableforCCU3howevertheirdocumentedfunctionalitymaybeachievedthroughtheuseofexistingCCU1andCCU2modules.MTBFiscalculatedusingrealdatafromtheCCU2,whichhassimilararchitecturetotheCCU3.
CCUNet integrates numerous fire networks into one simple interface
XL GraphicsTerminal
XL Network
Collective Panel
Simplex Network
Tyco MX Network
TLI800
Dial-up Remote XL Graphics Terminal
Pager
CCUNet
top related