PROJECTED BEAM SMOKE DETECTOR
S
H
ADDRESSABLE SMOKE DETECTOR
ADDRESSABLE HEAT DETECTOR
D
ADDRESSABLE DUCT SMOKE DETECTOR
XX
XX
WG = WIRE GUARDU = UNDER FLOOR
R = RELAY BASES = SOUNDER BASE
S = SUPPLYR = RETURN
XX
T = TRANSMITTER
R = RECEIVER
FIRE ALARM SYMBOL LEGEND
H
CONVENTIONAL HEAT DETECTOR
RC = RATE COMPENSATING TEMPERATURESET 190 DEGREES F.
XX
AC = ABOVE CEILING FIXED TEMPERATURESET AT 135 DEGREES F.(INSTALLED ABOVE ACCESSIBLE CEILING)
FX = FIXED TEMPERATURE SET 190 DEGREES F.
XX
ADDRESSABLE MANUAL PULL STATION
WG = WIRE GUARD
I = INSTITUTIONAL
F
I = INTRINSICALLY SAFE
SD = SMOKE DAMPERWP = WEATHER PROOF
EX = EXPLOSION PROOF .
EX = EXPLOSION PROOF .
FS CONNECTION TO SPRINKLER WATER FLOW SW.
TS CONNECTION TO SPRINKLER SUPERVISORY SW.
WP = WEATHER PROOF
CONNECTION TO MAGNETIC DOOR HOLDER
BELL STROBE UNIT
C ADDRESSABLE CONTROL MODULE
M ADDRESSABLE MONITOR MODULE
F WG = WIRE GUARD
EX = EXPLOSION PROOF .
WP = WEATHER PROOF
F
BELL UNIT
WG = WIRE GUARD
EX = EXPLOSION PROOF .
WP = WEATHER PROOF
FACP FIRE ALARM CONTROL PANEL
XX
F XX
HORN STROBE UNIT
WG = WIRE GUARDEX = EXPLOSION PROOF .
WP = WEATHER PROOF
THE FOLLOWING GENERAL NOTES AS LISTED BELOW SHALL APPLY TO ALL FIREALARM SYSTEM SCOPES OF WORK/REQUIREMENTS AS INDICATED ON THE EFSERIES CONTRACT DRAWINGS.
1.
GENERAL FIRE ALARM NOTES:
ALL EQUIPMENT SYMBOLS ARE SHOWN ON DRAWINGS AS CLOSE AS POSSIBLETO THEIR INTENDED LOCATION. CONTRACTOR SHALL COORDINATE IN THEFIELD THE PROPER INSTALLATION OF ALL EQUIPMENT, DEVICES, CONTROLSAND CABLING. REFER TO RELATED SPECIFICATION SECTIONS FOR ADDITIONALREQUIREMENTS.
2.
DRAWINGS FOR THIS WORK ARE DIAGRAMMATIC AND INTENDED TO CONVEYTHE EXTENT, GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK.BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS SUCH ASACCESS PANELS, CONDUITS, CABINET SIZES, PENETRATION SLEEVES, PULLBOXES, BACKBOXES AND JUNCTION BOXES MAY NOT BE SHOWN. INCLUDE ALLITEMS WHERE REQUIRED BY CODE, MANUFACTURER AND RELATEDSPECIFICATION SECTIONS FOR THE PROPER INSTALLATION OF ALL WORK.
3.
4.
6.
PROVIDE ALL EQUIPMENT CLEARANCES IN ACCORDANCE WITH NFPA 70REQUIREMENTS. ARRANGE EQUIPMENT TO FACILITATE UNRESTRICTED ACCESSFOR MAINTENANCE AND SERVICE AROUND ALL EQUIPMENT, COMPONENTSAND/OR CABLE TERMINATIONS.
7.
F XX
HORN UNIT
WG = WIRE GUARD
WP = WEATHER PROOF
EX = EXPLOSION PROOF .
SSPEAKER CEILING MOUNTED UNIT
WG = WIRE GUARD
WP = WEATHER PROOF
EX = EXPLOSION PROOF .
S
XX
SPEAKER WALL MOUNTED UNIT
WG = WIRE GUARD
WP = WEATHER PROOF
EX = EXPLOSION PROOF .XX
MN = MASS NOTIFICATION DEVICE
MN = MASS NOTIFICATION DEVICE
SXX
SPEAKER STROBE CEILING MOUNTED UNIT
WG = WIRE GUARD
WP = WEATHER PROOF
EX = EXPLOSION PROOF .
MN = MASS NOTIFICATION DEVICE
F
ADA STROBE UNIT WALL MOUNTED
WG = WIRE GUARD
WP = WEATHER PROOF
EX = EXPLOSION PROOF .
MN = MASS NOTIFICATION DEVICE
C = CEILING MOUNTED
W = WAll MOUNTED
S
ADA SPEAKER STROBE WALL MOUNTED
WG = WIRE GUARD
WP = WEATHER PROOFEX = EXPLOSION PROOF .
MN = MASS NOTIFICATION DEVICE
FAAP FIRE ALARM ANNUNCIATOR PANEL
FCPS FIELD CHARGING POWER SUPPLY
XX
XX
XX
DGP DATA GATHERING PANEL
MNSP MASTER RESCUE ASSISTANCE PANEL
FIRE FIGHTERS CONTROL STATIONFFCS PRT PRINTER
RAP
THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE 760 OF THE2006 NATIONAL ELECTRIC CODE. ALL FIRE ALARM CABLE MUST BE INSTALLED INDEDICATED CONDUITS IN ACCORDANCE WITH THE CABLING REQUIREMENTSSPECIFIED BY THE CONTRACT DOCUMENTS.
FIRE ALARM DEVICE MOUNTING HEIGHTS SHALL COMPLY WITH ALL ANSI 117, NFPA72 AND IBC REQUIREMENTS, AT THE MINIMUM INSTALL ALL DEVICES AS FOLLOWS: MANUAL PULL STATION: 48" A.F.F. TO CENTER AUDIBLE/VISUAL: 7'-0" A.F.F. TO CENTER OF STROBE LENS OR 8" BELOW CEILING TO CENTER OF STROBE LENS. VISUAL: 7'-0" A.F.F. TO CENTER OF STROBE LENS OR 8" BELOW CEILING TO CENTER OF STROBE LENS. EMERGENCY TELEPHONE JACKS: 48" A.F.F. TO CENTER
COORDINATE WITH ALL TRADES AND INTEGRATORS ALL CONDITIONS RELATED TOTHE INSTALLATION OF ALL DEVICES. THE CONTRACTOR SHALL COORDINATE WITHTHE APPROPRIATE TRADES AND SYSTEM INTEGRATORS ALL INSTALLATIONREQUIREMENTS IMPACTING THE PLACEMENT OF ALL SYSTEM COMPONENTS TOTHE SATISFACTION OF ALL CONCERNED TRADES.
8.
ALL SMOKE AND HEAT DETECTORS SHALL BE MOUNTED TO FINISHED CEILINGAND/OR DECKING, UNLESS NOTED OTHERWISE. DETECTORS SHALL NOT BEINSTALLED ON BOTTOM OF OPEN WEB JOISTS OR ON BEAMS EXCEEDING 12INCHES DEPTH FROM FINISHED CEILING OR DECK. REFER TO NFPA 72 FOR ALLINITIATING DEVICE INSTALLATION REQUIREMENTS. PROVIDE DETECTORS INSUFFICIENT QUANTITY TO COMPLY WITH ALL NFPA 72 REQUIREMENTS BASED ONCEILING CONDITIONS AND PROTECTED SPACE REQUIREMENTS.
9.
COORDINATE EXACT LOCATION(S) OF ALL CEILING MOUNTED CABLE,CONDUITS, EQUIPMENT AND/OR DEVICES WITH ALL ARCHITECTURAL PLANS,REFLECTED CEILING PLANS AND AFFECTED TRADES PRIOR TO INSTALLATION.
5.
PROTECTIVE ANTI-DUST COVERS SHALL BE INSTALLED AND MAINTAINED ON ALLSYSTEM SMOKE DETECTORS UNTIL FINAL ACCEPTANCE BY THE AUTHORITIES HAVINGJURISDICTION.
SMOKE DETECTORS SHALL NOT BE INSTALLED LESS THAN 3 FEET FROM ANY HVACSUPPLY OR RETURN AIR REGISTER AND A MINIMUM OF 1 FOOT AWAY FROM ALLLIGHTING FIXTURES.
WHERE EQUIPMENT AND/OR JUNCTION BOXES ARE INSTALLED ABOVE FINISHEDCEILINGS, THE CONTRACTOR SHALL PROVIDE ACCESS HATCHES LISTED FOR THEINTENDED APPLICATION. ACCESS HATCHES SHALL BE LOCATED SO THAT SERVICEACCESS TO THE EQUIPMENT AND/OR JUNCTION BOXES IS UNIMPEDED.
THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN DEDICATED CONDUITS. ALLCONDUITS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 AND THECONTRACT DOCUMENTS. ALL CONDUITS SHALL BE SIZED IN ACCORDANCE WITHNFPA 70 AND SHALL BE A MINIMUM OF 3/4" UNLESS OTHERWISE NOTED. REFER TORELATED SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION.
ALL CONDUITS/RACEWAYS SHALL BE INSTALLED IN A MANNER THAT PREVENTSTAMPERING OR REMOVAL WHEN INSTALLED IN AREAS EXPOSED TO THE GENERALPOPULATION. PROVIDE TAMPER-RESISTANT INSTALLATION UTILIZING "TORX WITHPEG" SECURITY-FASTENING DEVICES FOR ALL CONDUITS/RACEWAYS, EQUIPMENT,DEVICES AND APPURTENANCES IN ALL AREAS ACCESSIBLE TO THE GENERALPOPULATION AND/OR AREAS SUBJECTED TO TAMPERING OR VANDALISM. REFER TORELATED SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION.
PROVIDE APPROVED EARTH GROUND AT FIRE ALARM CONTROL PANEL. CHASSIS.A CONDUIT GROUNDING TO BUILDING STEEL SHALL NOT BE CONSIDERED AACCEPTABLE METHODOLOGY FOR GROUNDING OF FIRE ALARM CONTROL PANEL.
ALL SYSTEM WIRING AND EQUIPMENT INSTALLATIONS SHALL BE IN ACCORDANCEWITH GOOD ENGINEERING PRACTICES AND BY ALL IEEE, EIA, NEC ANDMANUFACTURER'S REQUIREMENTS. WIRING SHALL COMPLY WITH ALL STATE ANDLOCAL ELECTRICAL CODES. ALL WIRING SHALL TEST FREE FROM ALL GROUNDS,SHORTS AND EMI.
THE CONTRACTOR SHALL METER ALL WIRES AND CIRCUITS TO ENSURE THEY AREFREE OF ANY GROUNDS AND SHORTS PRIOR TO COMMISSIONING OF THE SYSTEM.
NO A.C. CARRYING CONDUCTORS ARE PERMITTED TO SHARE RACEWAYSWITH ANY FIRE ALARM INITIATING AND/OR NOTIFICATION CIRCUITS
ALL AUXILIARY ALARM RELAYS MUST BE INSTALLED WITHIN 3 FEET OF THEEQUIPMENT TO BE CONTROLLED IN ACCORDANCE WITH ALL NFPA 72REQUIREMENTS.
ALL FIRE ALARM DEVICES AND EQUIPMENT SHALL BE LABELED UNIQUEIDENTIFICATION NUMBER. ALL NUMBERS SHALL CORRESPOND WITH NUMBERINGSEQUENCE AS SUBMITTED ON THE PROJECT SHOP DRAWINGS. LABELS TO BESIMILAR TO "BROTHER P-TOUCH" BLACK LETTERING ON WHITE BACKGROUND,SELF-ADHESIVE TAPE. ALL DEVICE LABELS SHALL BE INSTALLED PRIOR TOSYSTEM CHECKOUT.
ALL PENETRATIONS OF WALLS AND FLOORS SHALL BE FIRE STOPPED INACCORDANCE WITH THE ASTM AND NFPA. REFER TO RELATED SPECIFICATIONSECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS SHALLBE PERFORMED BY AN APPLICATOR/INSTALLER QUALIFIED AND TRAINED BYTHE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICTACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.
ALL EQUIPMENT ENCLOSURES LOCATED EXTERIOR TO THE BUILDING OUTSIDE, OR IN ALLAREAS WITH HIGH HUMIDITY OF 75% OR GREATER SHALL BE NEMA 4X BACKBOXES RATEDFOR THAT APPLICATION.
REFER TO ALL RELATED SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION.
ALL EQUIPMENT EXPOSED TO THE ENVIRONMENT OR INSTALLED IN PROXIMITY TOAREAS WITH HIGH MOISTURE, OR A RELATIVE HUMIDITY OF 75% OR GREATER SHALLPROVIDED WITH ENCLOSURES AND OR BACKBOXES RATED FOR THEENVIRONMENTAL CONDITIONS.
THE STROBE INTENSITY OF ALL VISUAL NOTIFICATION APPLIANCES SHALL BE INACCORDANCE WITH NFPA 72 AND UL 1971. STROBE CANDELA RATINGS SHALL BEPROVIDED IN ACCORDANCE WITH DEVICE LOCATIONS AND SHALL CONFORM TOALL ICC/ANSI 117 AND NFPA 72 INSTALLATION REQUIREMENTS. CONTRACTOR SHALLPROVIDE THE REQUIRED CANDELA POWER AND LOCATE ALL VISUAL NOTIFICATIONAPPLIANCES AS REQUIRED TO MEET THE REQUIREMENTS OF ALL REFERENCEDCODES AND STANDARDS.
ALARM CAPABILITY DURING ABNORMAL CONDITIONS
TROUBLE INDICATION AT PROTECTED PREMISES
ABNORMAL CONDITION
SINGLE OPEN
SINGLE GROUND
WIRE-TO-WIRE SHORT
ALARM CAPABILITY DURING ABNORMAL CONDITIONS
TROUBLE INDICATION AT PROTECTED PREMISES
ALARM
ABNORMAL CONDITION
SINGLE OPEN
SINGLE GROUND
WIRE-TO-WIRE SHORT
WIRE-TO-WIRE SHORT & OPEN
WIRE-TO-WIRE SHORT & GROUND
OPEN & GROUND
LOSS OF CARRIER(IF USED)/CHANNEL INTERFACE
X
X
X
X
X
X
X
X
R
NOTIFICATION CIRCUITS NOTE:-THE ALARM SIGNAL DEVICES DO NOTHAVE TO BE WIRED SEQUENTIALLY BUT THEY:
-MUST BE INSTALLED IN ACCORDANCE WITH THESPECIFICATIONS
-MUST HAVE AN EOL-SHALL NOT BE T-TAPPED-MUST BE IN CONDUIT
INITIATION LOOP (SLC) NOTE:THE ALARM INITIATION DEVICES DO NOT HAVE TO BEWIRED SEQUENTIALLY BUT THEY:-MUST BE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS-DO NOT HAVE AN EOL-MAY BE T-TAPPED-MAY HAVE UNIQUE ADDRESSES-MUST BE IN CONDUIT
ADDRESSABLE FIRE ALARM SYSTEM CABLE TYPE
NFPA 72 PERFORMANCE CRITERIA
NOTIFICATION APPLIANCE CIRCUITS SIGNALING LINE CIRCUITS (SLC)
NFPA - CLASS B - STYLE Y NFPA - CLASS B - STYLE 4
CEILING SMOKE AND HEAT DETECTORS, 360° SECURITY MOTION DETECTORS, CCTV SURVEILLANCE CAMERAS, PUBLIC ADDRESS AND VOICE EVACUATION SPEAKERS, WIRELESS ACCESS POINTS. TV AND LCD PROJECTOR JACKS
7'-0" A.F.F. VISUAL AND AUDIO/VISUAL FIRE ALARM NOTIFICATION DEVICES, WALL MOUNTED SECURITY MOTION DETECTORS(CENTER OF DEVICE)
8' A.F.G. EXTERIOR VISUAL AND AUDIO/VISUAL FIRE ALARM NOTIFICATION DEVICES, EXTERIOR PUBLIC ADDRESS SPEAKERS.
6" ABOVE DOOR JAMB REQUEST TO EXIT MOTION DETECTORS
5'-6" A.F.F TOP OF PLYWOOD TELEPHONE BACKBOARD
5'-4" A.F.F. FIRE ALARM ANNUNCIATOR PANELS, FIRE FIGHTER CONTROL STATIONS, SECURITY ANNUNCIATOR PANELS
4'-8" A.F.G. MAX PEDESTAL MOUNT INTERCOM PEDESTAL MOUNT CARD READER
4'-0" A.F.F. INTERCOM STATIONS, FIRE FIGHTER TELEPHONE JACKS,FIRE ALARM MANUAL STATIONS, CARD READERS, MANUALREQUEST TO EXIT DEVICES, WALL MOUNTED DURESS ALARMSTATIONS, RESCUE ASSISTANCE PANELS, LCD KEYPADS(CENTER OF DEVICE)
UNDER COUNTER OR DESK DURESS ALARM BUTTONS, DOOR RELEASE BUTTONS
1'-6" A.F.F. DATA/TELEPHONE JACKS, LOW TELEVISION JACKS,MICROPHONE JACKS
0'-0" IN FLOOR JUNCTION BOXES FLUSH TO FINISHED FLOOR (FF)(DATA,TELEPHONE, MICROPHONE, MEDIA)
1. IN MASONRY CONSTRUCTION THE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO THENEAREST BLOCK OR BRICK COURSING.
2. THE ABOVE MOUNTING ELEVATIONS ARE TO CENTER OF DEVICE AND SHALL BE ADHERED TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE DRAWINGS AND/OR SPECIFICATIONS.
3. COORDINATE THE INSTALLATION AND MOUNTING ELEVATIONS OF ALL EQUIPMENT, DEVICES, CONTROLSAND APPURTENANCES WITH PROFESSIONAL AND ALL AFFECTED TRADES PRIOR TO INSTALLATION.DOCUMENT ALL MOUNTING ELEVATIONS FOR ALL EQUIPMENT, DEVICES, CONTROLS AND APPURTENANCESAT THE TIME OF SHOP DRAWING SUBMISSION.
STANDARD MOUNTING HEIGHTS
ROOM SPACING FOR WALL-MOUNTED VISIBLE APPLIANCESMINIMUM REQUIRED LIGHT OUTPUT (EFFECTIVE INTENSITY/CANDELA)IN ACCORDANCE WITH NFPA 72
20 X 20
30 X 30
40 X 40
50 X 50
60 X 60
70 X 70
80 X 80
90 X 90
100 X 100
110 X 110
120 X 120
130 X 130
15cd
30cd
60cd
95cd
135cd
185cd
240cd
305cd
375cd
455cd
540cd
635cd
N/A
15cd
30cd
60cd
95cd
95cd
135cd
185cd
240cd
240cd
305cd
375cd
N/A
N/A
15cd
30cd
30cd
30cd
60cd
95cd
95cd
135cd
135cd
185cd
N/A = NOT ALLOWABLE
NOTE: CONTRACTOR SHALL PROVIDE REQUIRED CANDELA RATEDSTROBES IN ACCORDANCE WITH THE ABOVE TABLE FOR ALL VISIBLEAPPLIANCES BASED ON LOCATION AS INDICATED ON THE CONTRACT
5 6
X
X
X
X
MAXIMUM RM. SIZEONE LIGHTPER ROOM
TWO LIGHTSPER ROOM
FOUR LIGHTSPER ROOM
ADDRESSABLE FIRE ALARM SYSTEM WIRE SCHEDULE
NEC DESIGNATION
POWER-LIMITED
POWER-LIMITED
POWER-LIMITED
POWER-LIMITED
POWER-LIMITED
POWER-LIMITED
POWER-LIMITED
CABLE
18 AWG
14 AWG
16 AWG
14 AWG
-
18 AWG
14 AWG
TWISTED
YES
NO
YES
NO
YES
YES
NO
No. OFCONDUCTORS
2
2
2
2
-
2
2
SHIELDED
PER MANUF.
PER MANUF.
YES
NO
NO
PER MANUF.
YES
NFPA CLASS
B
B
B
B
N/A
A
B
NFPA STYLE
4
Y
Y
N/A
N/A
7a
Y
IN CONDUIT
YES
YES
YES
YES
YES
YES
YES
NOTES
T-TAPPING PERMITTED BUT DISCOURAGED, NO EOLS
NO T-TAPPING CIRCUITS FROM FACPS: REQUIRED EOL, CIRCUITS FROM FCPS: REQUIRED EOL.
NO T-TAPPING CIRCUITS FROM FACPS: REQUIRED EOL, CIRCUITS FROM AMPLIFIERS/DGPS: REQUIRED EOL.
T-TAPPING PERMITTED
MAX. 25 FT CABLE RUN (GREATER THAN 25 FT IN LENGTH CONTRACTOR SHALL PROVIDE APPROPRIATE MODEMS)
NO T-TAPPING, 5000 FT MAX CABLE RUN
NO TAPPING, MANUFACTURERS REQUIRED EOL
LOCAL RESCUE ASSISTANCE PANEL MNSP MASS NOTIFICATION SYSTEM CONTROL PANEL
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
ABBREVIATIONS
above finished floorabove finished gradeaccentadjustablealternating currentaluminumAmerican wire gaugeammeterampereapproximatelyAssociationasymmetricattenuation/crosstalk ratioautomatic transfer switchbatterybelow finished ceilingblackbracketbreakercabinetcable televisionceilingcircuit breakerclearclosed circuit televisioncolumncommunicationconduitcool whitecoppercurrent limiting fusecurrent transformerdecibeldedicateddiameterdirect currentdisconnectdistribution paneldouble pole double-throwdownlightdrawingdual elementeachelectric water coolerelectrical contractorelectrically operatedelevatoremergencyenergy saving ballastequipmentexhaust fanexplosion proofelectronics industry association
AFFAFGACCADJACALAWGAMAMPAPPROXASSOCASYACRATSBATTBFCBLKBRKTBKRCABCATVCLGCIR/CKTCLRCCTVCOLCOMMCCWCUCLFCTDBDEDDIADCDISCDPDPDTDNLTDWGDEEAEWCECEOELEVEMERGESBEQUIPEFXPEIA
FEXTFAFAAPFACPFAGPFIXTFLFLOURFTFLAFVNRGCGENGFIHHHVACHZHIDHPFHVHPINCANIGJBKVARKVAKWIPSLTLTGLALVLEDMCBMDPMLOMHMTSMFRMATVMCMVMHMCC MISCMCPMCCMODMTDMTG HTMMMV
far end crosstalkfire alarmfire alarm annunciator panelfire alarm control panelfire alarm graphic annunciator panelfixturefloorfluorescentfootcandlesfull load amperesfull voltage non-reversinggeneral contractorgeneratorground fault interrupterhand holeheating ventilating air conditioninghertzhigh intensity dischargehigh power factorhigh voltagehorsepowerincandescentisolated groundjunction boxkilovar (reactance)kilovolt amperekilowatt hour meterinverter power supplylightlightinglightning arresterlow voltagelight emitting diodemain circuit breakermain distribution panelmain lugs onlymanholemanual transfer switchmanufacturermaster antenna televisionmechanical contractormedium voltagemetal halidemetal-clad cablemiscellaneousmotor circuit protectormotor control centermotor operated dampermountedmounting heightmillimetermillivolt
National Electrical Manufacturer AssocNational Electric CodeNear End Crosstalknight lightnormally openedNot Available/Not Applicablenot in contractnot to scaleon centeroverheadoverload heater elementpanelpewterplywoodpolepolyvinyl chloridepotential transformerpower panelpull boxrapid startreceptaclereflectorrequiredrigid galvanized steel conduitroomrough in onlyschedulesingle pole double throwsingle pole single throwsolid state ballastswitchswitchboardswitchgeartelephonetransformertwin tubetypicalTelecommunications Industry AssocTechnical Service Bulletintwisted shielded pairunshielded twisted pairUnderwriter's Laboratoriesuninterruptible power supplyunless otherwise notedvapor proofvoltvoltmeterwarm whitewattweatherproofwithwithinwithout
NEMANECNEXTNLNON/ANICNTSOCOHOLPNLPEWPLYPPVCPTPPPBRSREC/RECPTREFLREQ'DRGSRMRIOSCHED/SCHSPDTSPSTSSBSWSWBDSWGRTELEXFMRTTTYPTIATSBTSPUTPULUPSUONVPVVMWWWWPW/W/IW/O
NEC DESIGNATION*
FPLP
FPLR
FPL
DESCRIPTION
FIRE, POWER LIMITED, PLENUM
FIRE, POWER LIMITED, RISER
FIRE, POWER LIMITED
APPLICATION
SUITABLE FOR USE IN DUCTS, PLENUMS, AND OTHER SPACE USED FOR ENVIRONMENTAL AIR.
SUITABLE FOR USE IN A VERTICAL RUN IN A SHAFT OR WHEN A WIRE RUN PASSES FROM FLOOR TO FLOOR.
SUITABLE FOR GENERAL-PURPOSE FIRE ALARM USE IN CONDUITS, WITH THE EXCEPTIONS OF THE ABOVE APPLICATIONS.
* CABLE TYPES ARE LISTED IN DESCENDING ORDER OF FIRE-RESISTANT RATING, PER NFPA 70, TABLE 760-71(h)
CONDUCTOR MATERIAL
COPPER
COPPER
COPPER
ACCEPTABLE FOR PROJECT
YES
YES
NO
ADDRESSABLE FIRE ALARM SYSTEM WIRE SCHEDULE
ADDRESSABLE INITIATING LOOP (SLC)
NOTIFICATION APPLIANCE CIRCUIT (NAC)
NOTIFICATION APPLIANCE CIRCUIT (NAC)
24 VDC POWER
PRINTER CABLE
RS485 - NETWORK (SLC)
TYPICAL DEVICES
MANUAL STATIONS, SMOKE/HEAT DETECTORS, INTERFACE MODULES
HORNS, STROBES, BELLS
SPEAKERS
REMOTE ANNUNCIATORS, CONTROL MODULES, BEAM DETECTORS
COMMUNICATION BETWEEN FACPS AND TRANSPONDERS
CONVENTIONAL SMOKE, DUCT, HEAT AND BEAM DETECTORS
PRINTER
CONVENTIONAL INITIATING LOOP (IDC)
R
ARCHITECTURE ENGINEERING COMMUNICATIONS TECHNOLOGY.... ....
A CDI Company
emailweb site
architecture@lrkimball.comwww.lrkimball.com
615 West Highland AvenueEbensburg, PA 15931
(814) 472-7700(814) 472-7712
Corporate Headquarters
c
CONSULTANT
PROFESSIONAL
KEYPLAN
CHK'D BY :
DRAWN BY :
PROJECT NO :
DATE :
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
A
B
C
D
E
FILE NAME :
CDI Architects, Inc.
REVISIONS
LEONARDTOWN, MARYLAND
ADULTDETENTION
CENTEREXPANSION /RENOVATION
EF001
FIRE ALARMABBREVIATIONS,
SYMBOLS AND LEGEND
03 / 30 / 201210-1200-0146
AJFAJF
ST. MARY'S COUNTY
MARK DATE DESCRIPTION
UP
DW REF.
F
FACP
F
S
S
S
S
F
S
F F
F
F
F
FF
F
F
F
F
F
F
FF
F
F
F
F
FF
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
S
F
F F F
F
FF
F
F F
F
S S
H
SH
SH
F
F
F
S
F F
F
F
F
F
F
F
M
F
F FFF
F
FAAP
FAAP
MRAP
FS
TS
TS
D
D
D
D
FS
TS
FS
TS
FS
TS
FS
TS
D
D
S
C C C CC C C C
F
S H
SS
S S
F
I
WP
WP
WP
WP
15cd
15cd
15cd15cd
15cd
15cd
15cd
15cd
75cd75cd
75cd
75cd
15cd
75cd
75cd 75cd
75cd
75cd
75cd
75cd 75cd 75cd
75cd
75cd
75cd
75cd
I
75cd
75cd
75cd
75cd
75cd
15cd
75cd
75cd
15cd
75cd
75cd
15cd
75cd
75cd
75cd
75cd
75cd
15cd
75cd
75cd
75cd
75cd
75cd
75cd
TYP. KITCHENSUPPRESSION SYS.
75cd
15cd
LOBBY-1A102-1
STORAGEA148
JANITORA147
TOILETA146
LABA136
SEARCHA138
STAFF TOILETA127
JANITORA137
OFFICER STATIONA140
STORAGEA141
JANITORA117
WOMEN'S TLTA115
MEN'S TLTA116
CIVILIAN OFFICEA114
TOILETD108
WORK ROOMA118
RECEPTIONA105
BREAK ROOMA120
JANITORD116
MEN'S TLTD115
WOMEN'S TLTD117
TOILETD104TELE
D103
COMMISSIONER-1D102-1
BONDD105
CORRIDORE105
COMMISSIONER-2D102-2
SALLY PORTD106
OFFICEA109
PHYSICAL TRAININGD133
SERVERYD139A
STAGINGA132
SEARCHA134OFFICE
A145
MAINTENANCEA144
STORAGEA131
OFFICEA130
OFFICEA129
OFFICEA128
WOMEN'S LOCKER ROOMD130
STORAGEA113
WAITINGA104
PROGRAMS OFFICEA126
BREATHALYZERA133A
STAFF TOILETA142
OFFICEA110
OFFICEA108
HOLDINGA135
OFFICEA151
JANITORA152
TOILETA153
TOILETC104A
CORRIDORB103
CENTRAL CONTROLA123
STAFF TOILETA124
WARDEN OFFICEA107
CONFERENCE ROOMA106
OFFICEA111
CORRIDORA119
CORRIDORA133
SALLY PORTA122
STORAGEA155
LINT ROOMA156
STORAGEA154
STORAGEA149
WORK RELEASE PROCESSINGA139
VESTIBULEA143
MDF ROOMA112
RECORDSA121
LAUNDRYA150
VESTIBULEB101
CORRIDORD114
MEN'S LOCKER ROOMD129
CORRIDORB105
JANITORC108
ELEVATOR EQUIPMENTC107
LOBBY-2A102-2
INMATE TOILETB110
PUBLIC LOBBYD101
CORRIDORA103
CORRIDORD132
75cd 75cd75cd
I
R
S
R
S
R
S
ELEVATOR F/AINTERFACE (TYP)
I
ELEVATOR PIT (TYP)
75cd
?
190
75cd
AB C
D
E
F
R
ARCHITECTURE ENGINEERING COMMUNICATIONS TECHNOLOGY.... ....
A CDI Company
emailweb site
architecture@lrkimball.comwww.lrkimball.com
615 West Highland AvenueEbensburg, PA 15931
(814) 472-7700(814) 472-7712
Corporate Headquarters
c
CONSULTANT
PROFESSIONAL
KEYPLAN
CHK'D BY :
DRAWN BY :
PROJECT NO :
DATE :
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
A
B
C
D
E
FILE NAME :
CDI Architects, Inc.
REVISIONS
LEONARDTOWN, MARYLAND
ADULTDETENTION
CENTEREXPANSION /RENOVATION
EF111A
FIRE ALARM SYSTEMPARTIAL FIRST FLOOR
PLAN - AREA A
03 / 30 / 201210-1200-0146
AJFAJF
ST. MARY'S COUNTY
1/8" = 1'-0"1 EF FIRST FLOOR AREA "A"
MARK DATE DESCRIPTION
UP
DN
Tectonic Cop
yright 2007
Tectonic Cop
yright 2007
UP
F
F
F
S
S
S
S
F F
F
F
F
F
F
F
F
F
F
F
F F F
F
F
F
F
F FF
F
F
F
F
F
F
F
F
F
S S
H
SH
SH
F
F
F
F
F F F
F
M M
F
F
F
F F
S S
F
F
F
F
FS
TS
FS
TS
TS
TS
TS
FS
TS
FS
TS
TS
TS
FS
TS
FS
TS
TS
FS
TS
FS
TS
FS
TS
FS
TS
D
D
D
D
D
D
F
F
C C C CC C C C
F
D
D
D
D
D
D
D
I
WP
I
WP
15cd
15cd
TYP. KITCHENSUPPRESSION SYS.
75cd
75cd
75cd
75cd
75cd
75cd
75cd
15cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd 75cd 75cd
75cd
75cd
75cd
75cd75cd
15cd
JANITORB115
TOILETB116
STAGINGA132
SEARCHA134OFFICE
A145
CLASSROOMB106
COMPUTER CLASSROOMB108
ELECTRIC ROOMB104B
EMERGENCY POWER ROOMB104A
TOILETA153
TOILETC104A
INMATE TOILETC105C
JANITORC105B
CORRIDORB103
PUMP ROOMB104C
CORRIDORC102
DRY STORAGEC105A
STAGINGC103
OFFICEB117
SECURE STORAGEB118
WAREHOUSEB114
CLASSROOMB107
CORRIDORC101
OFFICEC104
SALLY PORTA122
VESTIBULEB101
STAIR-2ST02-2
STAIR-2ST01-2
MECHANICAL ROOMB104
FOOD SERVICEC105
CORRIDORB105
CORRIDORC106
ELECTRIC ROOMC110
COMMUNICATIONS EQUIPMENTROOMC109JANITOR
C108
ELEVATOR EQUIPMENTC107
LIEUT. OFFICEB112
LIEUT. OFFICEB111
COMMISSARYB113
INMATE TOILETB110
EQUIPMENTB109
75cd
75cd
75cd 75cd75cd
WP
I
75cd
R
S
R
S
R
S
ELEVATOR F/AINTERFACE (TYP)
75cd
WP
I
ELEVATOR PIT (TYP)
SD
SD
SD
SD
SD
SD
SD
AB C
D
E
F
R
ARCHITECTURE ENGINEERING COMMUNICATIONS TECHNOLOGY.... ....
A CDI Company
emailweb site
architecture@lrkimball.comwww.lrkimball.com
615 West Highland AvenueEbensburg, PA 15931
(814) 472-7700(814) 472-7712
Corporate Headquarters
c
CONSULTANT
PROFESSIONAL
KEYPLAN
CHK'D BY :
DRAWN BY :
PROJECT NO :
DATE :
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
A
B
C
D
E
FILE NAME :
CDI Architects, Inc.
REVISIONS
LEONARDTOWN, MARYLAND
ADULTDETENTION
CENTEREXPANSION /RENOVATION
EF111B & C
FIRE ALARM SYSTEMPARTIAL FIRST FLOOR
PLAN -AREA B & C
03 / 30 / 201210-1200-0146
AJFAJF
ST. MARY'S COUNTY
1/8" = 1'-0"1 EF FIRST FLOOR AREA "B & C"
MARK DATE DESCRIPTION
F
S
S
S
S
S
S
S
F
F
F F
F
F
F
F
F
F
FF
F
FF
F
F
F
F
F
FF
F
F F
F
F
F
F
F
F
F
F
H
SH
SH
FF
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
M
F
F
F
S
S
S
S
S
S
S
S
S S S S
F
S S
F
F
F
F
F
TS
S
S
C C C CC C C C
F
F
S H
S S
SS
S S
D
D
D
D
D
D
I
WP
WG
WG
WP
WP
WP
15cd
15cd
15cd
15cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
15cd
EXISTING FIRE ALARM CONTROL PANELSTO BE DEMOLISHED
15cd
75cd
75cd75cd
75cd
75cd
75cd75cd
75cd
75cd
75cd
15cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
TYP. KITCHENSUPPRESSION SYS.
75cd
75cd
75cd
75cd
75cd
75cd
75cd
WG
WG
WG
WGWG
WG
WG
WG
WG WG WG WG
INDOOR EXERCISED151
TOILETD108
SUPERVISORD125
ERT TACTICAL ROOMD131
TRAINING OFFICERD137
JANITORD127
JANITORD116
MEN'S TLTD115
WOMEN'S TLTD117
TOILETD104TELE
D103
INTERVIEWD113
ELECD111
HOLDINGD110
CELLD110C
CELLD110B
CELLD110A
CELLD110E
OBSERV CELLD110D
CELLD110G
CELLD110F
TANKD112
EQUIPMENTD109
VENDINGD132B
SHIFT SUPERVISORS SERGEANTSD157
MEDICAL CELLD142A
MEDICAL CELLD142B
CELLD159B
CELLD159A
CELLD159C
SALLY PORTD158
ISOLATIOND159
TOILETD155
CLOSETD157A
STORAGED156
SHOWERD159E
TOILETD159D
CORRIDORD169
TRANSPORTD107
CELLD161B
CELLD161A
CELLD161C
SALLY PORTD160
ISOLATIOND161
SHOWERD161E
TOILETD161D
JANITORD168
ELECD166
TOILETD167
OFFICED165
STORAGED163
COMMD162
OFFICED164
LIBRARYD148
COMMD149COUNSELOR
D150
MULTI-PURPOSED153
STORAGED154
CONTROLF125
CELLD175A
CELLD175B
CELLD175C
CELLD175D
DAYROOMD175
SHOWERD175F
TOILETD175E
TOILETD174E
SHOWERD174F
CELLD174A
CELLD174B
CELLD174C
CELLD174D
DAYROOMD174
CONTROLD170
CELLD172A
CELLD172B
CELLD172C
CELLD172D
DAYROOMD172
CORRIDORD171
SHOWERD172F
TOILETD172E
TOILETD173E
SHOWERD173F
CELLD173A
CELLD173B
CELLD173C
CELLD173D
DAYROOMD173
CORRIDORD176
CORRIDOR-2D152-2
BONDD105
CORRIDORE105
COMMISSIONER-2D102-2
SALLY PORTD106
VESTIBULED132A
PHYSICAL TRAININGD133
SERVERYD139A
STAFF DININGD139
PROFESSIONAL VISITATIOND119
ATTYD123
ATTYD122
ATTYD121
ATTYD120
VIDEO BAIL BONDD124
CORRIDOR-1D128-1
CORRIDOR-2D128-2
VIDEO VISITATIOND118
STORAGED135
ADMIN ASSISTANTSD136
OBSERV CELLD146A
ANTE ROOMD144
STORAGED140
JANITORD141
WARDD143
MEDICAL INFIRMARYD142
NEGATIVE PRESSURE CELLD145
WOMEN'S LOCKER ROOMD130
CORRIDORD114
MEN'S LOCKER ROOMD129
ELECTRIC ROOMC110
COMMUNICATIONS EQUIPMENTROOMC109JANITOR
C108
ELEVATOR EQUIPMENTC107
LOBBY-2A102-2
WARDD147
PUBLIC LOBBYD101
SALLY PORTD138
CORRIDORC111
CORRIDORA103
BRIEFING/TRAINING ROOMD134
CORRIDORD132
I
75cd
I
ELEVATOR F/AINTERFACE (TYP)
ELEVATOR PIT (TYP)
75cd
75cd
?
190
WG WG
75cd
R
S
R
S
R
S
AB C
D
E
F
R
ARCHITECTURE ENGINEERING COMMUNICATIONS TECHNOLOGY.... ....
A CDI Company
emailweb site
architecture@lrkimball.comwww.lrkimball.com
615 West Highland AvenueEbensburg, PA 15931
(814) 472-7700(814) 472-7712
Corporate Headquarters
c
CONSULTANT
PROFESSIONAL
KEYPLAN
CHK'D BY :
DRAWN BY :
PROJECT NO :
DATE :
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
A
B
C
D
E
FILE NAME :
CDI Architects, Inc.
REVISIONS
LEONARDTOWN, MARYLAND
ADULTDETENTION
CENTEREXPANSION /RENOVATION
EF111D
FIRE ALARM SYSTEMPARTIAL FIRST FLOOR
PLAN - AREA D
03 / 30 / 201210-1200-0146
AJFAJF
ST. MARY'S COUNTY
1/8" = 1'-0"1 EF FIRST FLOOR AREA "D"
MARK DATE DESCRIPTION
Tectonic Cop
yright 2007
F
S
S
S
S
F
F
F
F
F
F
F
F
F
F
F
F
F
FF
F FF
F
F
F
F
F
F
F
F
FF
F
F F
F
FF
F
F
F
F
F
F
F
F
F
S
S
S S
F
F
F
F
FS
TS
FS
TS
FS
TSTS TS TS
D
D
D
D
S
S
S S
S
H
D
D
I
WP
WP
WP
15cd
15cd
15cd
15cd
75cd
75cd15cd
75cd 75cd
75cd 75cd75cd75cd
75cd75cd
75cd
75cd
75cd75cd
75cd75cd
75cd
75cd
75cd
75cd
75cd
75cd 15cd
75cd 75cd
75cd
15cd
75cd
75cd
75cd
75cd
75cd75cd
WG WG
WG
WG
BOOKINGE107
TELEE101
SHOWERE152E
TOILETE152F
HOLDINGE141
SHOWERE151E
TOILETE151F
CONTROLE148
STAFF TOILETE149
CELLE151D
DAYROOME152
DAYROOME151
CELLE151C
CELLE151B
CELLE151A
CELLE141A
CELLE141B
CORRIDORE140
TOILETE138
JANITORE139
TOILETE144
ISSUEE143
TOILETE146
JANITORE147
CLEAN UPE142
SHOWERE145
TOILETD104TELE
D103
COMMISSIONER-1D102-1
ELECD111
CELLD110C
CELLD110B
CELLD110A
TANKD112
MEDICAL CELLD142A
MEDICAL CELLD142B
LIBRARYD148
ARMORYE117
CELLE152A
CELLE152B
CELLE152C
CELLE152D
ACTIVE RECORDSE109
REPORT WRITINGE110
SALLY PORTE103
MECHANICAL ROOME102
CORRIDOR-1D152-1
BONDD105
CORRIDORE105
COMMISSIONER-2D102-2
SALLY PORTD106
OBSERV CELLD146A
STORAGED140
JANITORD141
MEDICAL INFIRMARYD142
TRIAGEE114
INMATE TOILETE113
JANITORE118
SUPERVISORE120
ISSUEE121
INMATE PROPERTYE122
MEDICAL TREATMENTE127
EXAME129
OFFICEE133
EXAME131
OFFICEE135
SHOWER / TOILET-1E137-1
RECORDSE126
STORAGEE128
PHARMACYE136
INMATE TOILETE134
JANITORE130
BIO HAZARDE132
CLOTHING EXCHANGEE119
SHOWER / TOILET-2E137-2
SHOWER / TOILET-3E137-3
INTAKEE106STAFF TOILET
E108
MEDICAL CLINICE125
VEHICLE S.P.E116
SALLY PORTE115
INMATE PROPERTYE123
HOLDINGE112
GROUP HOLDINGE111
75cd
I
I
R
S
R
S
WG WG
190
R
S
AB C
D
E
F
R
ARCHITECTURE ENGINEERING COMMUNICATIONS TECHNOLOGY.... ....
A CDI Company
emailweb site
architecture@lrkimball.comwww.lrkimball.com
615 West Highland AvenueEbensburg, PA 15931
(814) 472-7700(814) 472-7712
Corporate Headquarters
c
CONSULTANT
PROFESSIONAL
KEYPLAN
CHK'D BY :
DRAWN BY :
PROJECT NO :
DATE :
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
A
B
C
D
E
FILE NAME :
CDI Architects, Inc.
REVISIONS
LEONARDTOWN, MARYLAND
ADULTDETENTION
CENTEREXPANSION /RENOVATION
EF111E
FIRE ALARM SYSTEMPARTIAL FIRST FLOOR
PLAN - AREA E
03 / 30 / 201210-1200-0146
AJFAJF
ST. MARY'S COUNTY
1/8" = 1'-0"1 EF FIRST FLOOR AREA "E"MARK DATE DESCRIPTION
S
S
S
S
S
S
F
F
F
F
F
F
F
F
F
F
F
F
F
FF
F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
F
F
F
F
F
FS
TS
FS
TS
D
D
D
D
S S
SS
SS
?
I
I
I
WP
WP
WP
WP
15cd
15cd
15cd
15cd
75cd 75cd
75cd
75cd
WP
75cd
75cd
75cd
15cd
15cd75cd
75cd
75cd
75cd75cd
WP
WP
WP
WP
75cd
75cd
75cd
75cd
75cd
75cd75cd
WG
WG
WG
WGWG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
WG
JANITORE147
JANITORD168
CONTROLF125
CELLD175A
CELLD175B
CELLD175C
CELLD175D
CELLFD129
CELLFD128
CELLFD127
SHOWERFD131
TOILETFD132
TOILETFD126
SHOWERFD125
CELLFD121
CELLFD122
CELLFD123
CELLFD124
DAYROOMFD105
CELLFD109
CELLFD110
CELLFD111
CELLFD112
DAYROOMFD107
SHOWERFD114
TOILETFD113
TOILETFD115
SHOWERFD116
CELLFD120
CELLFD119
CELLFD118
CELLFD117
DAYROOMFD106
DAYROOMFD104
CELLFD130
CELLFD133
CELLFD134
CELLFD135
CELLFD136
DAYROOMFD103
SHOWERFD138
TOILETFD137
TOILETFD139
SHOWERFD140
CELLFD143
CELLFD142 CELL
FD141
CONTROLFD101
CORRIDORFD108
DAYROOMFD102
CELLFD144
CELLFA127
CELLFA126
CELLFA125
SHOWERFA129
TOILETFA130
TOILETFA123
SHOWERFA122
CELLFA118
CELLFA119
CELLFA120 CELL
FA121
DAYROOMFA117
CELLFA104
CELLFA105
CELLFA106
CELLFA107
DAYROOMFA103
SHOWERFA109
TOILETFA108
TOILETFA111
SHOWERFA112
CELLFA116
CELLFA115
CELLFA114CELL
FA113
DAYROOMFA110
CELLFA128
DAYROOMFA124
CELLFA132
CELLFA133
CELLFA134
CELLFA135
DAYROOMFA131
SHOWERFA137
TOILETFA136
TOILETFA139
SHOWERFA140
CELLFA144
CELLFA143
CELLFA142
CELLFA141
DAYROOMFA138
CORRIDORFA102
CONTROLFA101
P T COORDF109
INMATE TOILETF108
CONFERENCE ROOMF110
RECEPTIONF111
ACC OFFICEF112
CORRIDORF117
STAFF TOILETF114
JANITORF118
CLOSETF113
CORRIDOR-1F107-1
EMERGENCY EXIT SECURITY YARDF122
EMERGENCY EXIT SECURITY YARDF123
INMATE PROGRAM AREAF115
CORRIDOR-2F107-2
ELECTRIC ROOMF116
STAIRF121
CELLFB105
CELLFB106
CELLFB107
CELLFB108
STORAGEFB110
HC CELLFB109
JANITORFB111
CHASEFB114
CELLFB104
SALLY PORTFC101
SALLY PORTFB101
CONTROLF119
STAFF TOILETF120
TOILETFB112
SHOWERFB113
STAIRFB103
DAYROOMFB102
CELLFC109
CELLFC110
CELLFC111
CELLFC112
CELLFC113
STORAGEFC108
CHASEFC106
TOILETFC105
SHOWERFC107
STAIRFC103
JANITORFC104
HC CELLFC114
ANTE ROOMFC115
DAYROOMFC102
OUTDOOR EXERCISEF101
CORRIDORF124
CORRIDORF102
CORRIDORF103
75cd
R
S
R
S
D
E
F
R
ARCHITECTURE ENGINEERING COMMUNICATIONS TECHNOLOGY.... ....
A CDI Company
emailweb site
architecture@lrkimball.comwww.lrkimball.com
615 West Highland AvenueEbensburg, PA 15931
(814) 472-7700(814) 472-7712
Corporate Headquarters
c
CONSULTANT
PROFESSIONAL
KEYPLAN
CHK'D BY :
DRAWN BY :
PROJECT NO :
DATE :
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
A
B
C
D
E
FILE NAME :
CDI Architects, Inc.
REVISIONS
LEONARDTOWN, MARYLAND
ADULTDETENTION
CENTEREXPANSION /RENOVATION
EF111F
FIRE ALARM SYSTEMPARTIAL FIRST FLOOR
PLAN - AREA F
03 / 30 / 201210-1200-0146
AJFAJF
ST. MARY'S COUNTY
1/8" = 1'-0"1EF FIRST FLOOR AREA "F"
MARK DATE DESCRIPTION
UP
DN
UP UP
UPUPUP
UP
DN
F
F
F
F
F
F
FF
F F
F F
D D
DDD
D D
DD
D
D
D D
DD
D
D
D
D
F F
F
F
FF
F
FF
F
FF
F
F
F
F F
FF F
RAPRAP
F
FS
TS
FS
TS
S S
S
S
F
F
S S
DD D
DD
D
DD D
DD
D
D
DD
D
D
F
F
F
F
D D D D D D
D
D
D
D
D
D
D
D
D D D D D D
S
S
S
S
S
S
S
S
S
S
S
S
S
S
D
D
D
D
FS
TS
FS
TS
D
D
D
D
I
I
WG WG
I
WG
I
I
II
WG WG
15cd
15cd
75cd
15cd15cd
15cd
75cd 75cd
15cd15cd
15cd
15cd15cd
15cd
75cd 75cd 75cd 75cd
15cd
15cd
15cd
LAUNDRYBA205
JANITORBA206
STAFF TOILETBA213
LAUNDRYBB205
JANITORBB206
STAFF TOILETBB213
LAUNDRYCA205
JANITORCA206
STAFF TOILETCA213
LAUNDRYAB205
JANITORAB206
STAFF TOILETAB213
STAFF TOILETAA213
SHOWERAB204
SHOWERCA204
INMATE TOILETC203
DORMBB210
DORMAA210
O SAA214
O SAB214
O SCA214
O SBB214
O SBA214
STORAGEAB202
SALLY PORTAB201
VIDEO VISITATIONAB212
DAYROOMAB203
VIDEO VISITATIONAA212
DORMAB210
SALLY PORTBA201
VIDEO VISITATIONBA212
SALLY PORTBB201
VIDEO VISITATIONBB212
MULTI-PURPOSEBB211
STORAGECA202
SALLY PORTCA201
VIDEO VISITATIONCA212
DAYROOMCA203
CORRIDORB202
STORAGEBA202
CORRIDORC201
MULTI-PURPOSEBA211
STORAGEBB202
STORAGEAA202
DORMBA210
SALLY PORTAA201
DAYROOMBB203
SHOWERBB204
EXERCISECA208
EXERCISEBB208
EXERCISEBA208
MULTI-PURPOSECA211
STORAGEC204
TRIAGEC202
MULTI-PURPOSEAB211
EXERCISEAA208
EXERCISEAB208
DORMCA209DORM
CA207
DORMBB209DORM
BB207
DORMBA209DORM
BA207
DORMAA209
DORMAB207DORM
AB209
MULTI-PURPOSEAA211
STAIR VESTB201
STORAGEC205
STAIR VESTC206
DORMCA210
STAIR-3ST02-3
STAIR-3ST01-3
SHOWERBA204
LAUNDRYAA205
JANITORAA206
DAYROOMAA203
SHOWERAA204
DORMAA207
DAYROOMBA203
15cd
ALTERNATE -1HOUSING UNIT
SEE G103 FOR BASE BID PLAN
R
RR
R
RRR
R
R
R R
R
R
R
R
75cd
75cd
75cd
MECHANICAL ROOMF221
CELLF202
CELLF203
CELLF204
CELLF205
CELLF206
CELLF201
CELLF211
CELLF212
CELLF213
CELLF214
CELLF215
CELLF216
CELLF210
CELLF209
CELLF208
CELLF207
CELLF220
CELLF219
CELLF218
CELLF217
S
R
S
R S
R
S
R
RR R R R R
R
R
R
R
R
R
R
R
RRR
RRR
AB C
D
E
F
R
ARCHITECTURE ENGINEERING COMMUNICATIONS TECHNOLOGY.... ....
A CDI Company
emailweb site
architecture@lrkimball.comwww.lrkimball.com
615 West Highland AvenueEbensburg, PA 15931
(814) 472-7700(814) 472-7712
Corporate Headquarters
c
CONSULTANT
PROFESSIONAL
KEYPLAN
CHK'D BY :
DRAWN BY :
PROJECT NO :
DATE :
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
A
B
C
D
E
FILE NAME :
CDI Architects, Inc.
REVISIONS
LEONARDTOWN, MARYLAND
ADULTDETENTION
CENTEREXPANSION /RENOVATION
EF112
FIRE ALARM SYSTEMSECOND FLOOR PLAN
AREAS "A", "B", "C"AND "F"
03 / 30 / 201210-1200-0146
AJFAJF
ST. MARY'S COUNTY
1/8" = 1'-0"1 EF SECOND FLOOR AREA "A, B & C"
1/8" = 1'-0"2EF SECOND FLOOR AREA "F"
MARK DATE DESCRIPTION
DN
DNDN
DNDNDN
UPDN
UP
S S
S S
F F
H S
SS
H S
S S
D D
DD
S S
D
S S
S S
S S
D D
DD
S S
S S
S S
S S
D
D
SS
D D
DD
D
D
S S
S S
S S
S S
S S
S S
S S
S S
D
D
S
S
F F
F F
FF
FF F
RAP
F
TS
FS
TS
FS
TS
FSS
TS
FS
S
S
F
TS
FS
TS
FS
TS
FS
F
S S
DD D
DD
D
DD D
DD
D
D
DD
D
D
75cd75cd
I75cd
75cd
15cd
15cd 15cd
15cd15cd
BALCONYAB302
BALCONYBB302
COMMUNICATIONS EQUIPMENTROOMB309
JANITORAB307
SALLY PORTAB301
ELECTRIC ROOMB305
JANITORAA307
SALLY PORT-1AA301-1
JANITORBA307
SALLY PORTBA301
OFFICEB304
ELECTRIC ROOMB306
JANITORBB307
SALLY PORTBB301
OFFICE-1B308-1
ELECTRIC ROOMC302
JANITORCA307
BALCONYCA302
SALLY PORTCA301
OFFICEC304
DORMAA303
DORMAA306
BALCONYAA302
DORMAB306
DORMBA304
DORMBA303
DORMBB306
DORMCA306
DORMAB303
DORMBB304
DORMBB303
BALCONYBA302
DORMCA304DORM
CA305DORMBB305
COMMUNICATIONS EQUIPMENTROOMB302
STORAGEC303
OFFICEB307
DORMAA304
DORMAB304
DORMAB305
CORRIDORB301
CORRIDORC301
DORMCA303
STAIR-1ST02-1
STAIR-1ST01-1
DORMBA306
OFFICE-1B303-1
DORMBA305
DORMAA305
75cdI
STORAGE-1C306-1 STAFF TLT-1
C305-1
ALTERNATE -1HOUSING UNIT
SEE G103 FOR BASE BID PLAN
R
R
R
R
R
RR
R
R
R
R
R
R
R R
R R
R
R
75cd 75cd
SDSD SD
SDSD
SD
SD SD SD
SDSD
SD
SD
SDSD
S
R
AB C
D
E
F
R
ARCHITECTURE ENGINEERING COMMUNICATIONS TECHNOLOGY.... ....
A CDI Company
emailweb site
architecture@lrkimball.comwww.lrkimball.com
615 West Highland AvenueEbensburg, PA 15931
(814) 472-7700(814) 472-7712
Corporate Headquarters
c
CONSULTANT
PROFESSIONAL
KEYPLAN
CHK'D BY :
DRAWN BY :
PROJECT NO :
DATE :
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
A
B
C
D
E
FILE NAME :
CDI Architects, Inc.
REVISIONS
LEONARDTOWN, MARYLAND
ADULTDETENTION
CENTEREXPANSION /RENOVATION
EF113
FIRE ALARM SYSTEMSECOND FLOOR
MEZZANINE PLAN
03 / 30 / 201210-1200-0146
AJFAJF
ST. MARY'S COUNTY
1/8" = 1'-0"1 EF SECOND FLOOR MEZZANINE AREA "A, B & C"
MARK DATE DESCRIPTION