April 2006/2
Uric Acid FS TBHBA Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 3021 .. .. …
Notes
1. Please refer to the package insert for Uric Acid FS TBHBA for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
UA-DI Urate DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 550 M 3.6 8.2
Cal. Life time
Bichromatic 0 W 2.3 6.1 0 Days
Vols (µl) Times (sec) Limits
Sample 4 2nd Reag 300 Low Conc 0.07
1st Reag 200 Incubation 600 High Conc 20
2nd Reag 50 Interval 0 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Albumin FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 0220 .. .. …
Notes
1. Please refer to the package insert for Albumin FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
ALBU-DI ALBUMIN DIASYS g/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 550 M 3.5 5.2
Cal. Life time
Bichromatic 0 W 3.5 5.2 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 0
1st Reag 300 Incubation 300 High Conc 6
2nd Reag 0 Interval 0 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 0.35 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Amylase CC FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 0501 .. .. …
Notes
1. Please refer to the package insert for Amylase CC FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
AMY Amylase DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 405 M 0 215
Cal. Life time
Bichromatic 0 W 0 215 0 Days
Vols (µl) Times (sec) Limits
Sample 4 2nd Reag 60 Low Conc 3
1st Reag 200 Incubation 120 High Conc 4827
2nd Reag 50 Interval 0 Consumption 0.35
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 0
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2007/3
Bilirubin Auto Direct FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 0821 .. .. …
Notes
1. Please refer to the package insert for Bilirubin Auto Direct FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
Bili D Bili D DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Endpoint
Principal 550 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 24 2nd Reag 180 Low Conc 0.1
1st Reag 200 Incubation 300 High Conc 10
2nd Reag 50 Kinetics2 0 Consumption 0
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum -0.5 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2007/3
Bilirubin Auto Total FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 0811 .. .. …
Notes
1. Please refer to the package insert for Bilirubin Auto Total FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
Bili T Bili T DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Endpoint
Principal 550 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 6 2nd Reag 300 Low Conc 0.07
1st Reag 200 Incubation 300 High Conc 30
2nd Reag 50 Kinetics2 0 Consumption 0
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Calcium AS FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 1130 .. .. …
Notes
1. Please refer to the package insert for Calcium AS FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
Calc Calcium DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 650 M ** **
Cal. Life time
Bichromatic 700 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 0.04
1st Reag 300 Incubation 300 High Conc 25
2nd Reag 0 Interval 0 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Integrity
Decimals 2
2nd Reag 0 Blank
Temperature 37
Dilution
1: 1
Dilution Exclusive
-
January 2008/1
CK-MB FS Autolyzer / MetroLab 2300 – MONOREAGENT APPLICATION
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 1651 .. .. …
Notes
1. Please refer to the package insert for CK-MB FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
CK-MB CK-MB DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 340 M 0 24
Cal. Life time
Bichromatic 0 W 0 24 0 Days
Vols (µl) Times (sec) Limits
Sample 8 2nd Reag 0 Low Conc 2
1st Reag 200 Incubation 300 High Conc 1032
2nd Reag 0 Interval 0 Consumption 0.125
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
January 2008/1
CK-NAC FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 1601 .. .. …
Notes
1. Please refer to the package insert for CK-NAC FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
CK-DI CK-NAC DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 340 M 24 195
Cal. Life time
Bichromatic 0 W 24 170 0 Days
Vols (µl) Times (sec) Limits
Sample 10 2nd Reag 180 Low Conc 1
1st Reag 200 Incubation 120 High Conc 1032
2nd Reag 50 Interval 0 Consumption 0.25
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Chloride FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 1200 .. .. …
Notes
1. Please refer to the package insert for Chloride FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
CL CHLORIDE DIASYS mmol/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 450 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 1
1st Reag 300 Incubation 300 High Conc 130
2nd Reag 0 Kinetics2 0 Consumption 0
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Cholesterol FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 1300 .. .. …
Notes
1. Please refer to the package insert for Cholesterol FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
CHOL-DI CHOL DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 505 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 3
1st Reag 300 Incubation 600 High Conc 750
2nd Reag 0 Interval 0 Consumption 0
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 0.3 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
June 2009/1
Cholinesterase FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 1401 .. .. …
Notes
1. Please refer to the package insert for Alkaline Cholinesterase FS for detailed information about the test on the
following: Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
CHE-DI CHE DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 405 M 4620 11500
Cal. Life time
Bichromatic 0 W 3930 10800 0 Days
Vols (µl) Times (sec) Limits
Sample 4 2nd Reag 180 Low Conc 50
1st Reag 200 Incubation 120 High Conc 20000
2nd Reag 50 Interval 0 Consumption 0.3
Reference Single point Direction
Single point Factor 65692 Increase
Multipoint Standard 0 Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum -1 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl
1st Reag 0 Blank (Color Meth)
Decimals 0
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2008/3
Creatinine FS Autolyzer / MetroLab 2300 – MONOREAGENT APPLICATION
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 1711 .. .. …
Notes
1. Please refer to the package insert for Creatinine FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
CREA-DI CREAT DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max 2-Pt Kinetics
Principal 505 M 0.9 1.3
Cal. Life time
Bichromatic 0 W 0.6 1.1 0 Days
Vols (µl) Times (sec) Limits
Sample 10 2nd Reag 0 Low Conc 0.2
1st Reag 200 Incubation 60 High Conc 15
2nd Reag 0 Interval 120 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum -0.5 Provisory
Replacement
Intercept 0 Maximum 0.5 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2008/3
Creatinine FS – Compensated Method Autolyzer / MetroLab 2300 – MONOREAGENT APPLICATION
*calculated by the instrument # concentration entered by the user ** entered by the user
Compensated Method
To use the Creatinine FS Compensated Method on the Autolyzer the Calculation Intercept must be changed as follows; When the units are mg/dL
Calculation Intercept - 0.3
When the units are µmol/L
Calculation Intercept - 27
Note: Ensure that when using the Creatinine Compensated Method the relevant assigned Calibrator value is selected **This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
CREA-DI CREAT DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max 2-Pt Kinetics
Principal 505 M 0.9 1.3
Cal. Life time
Bichromatic 0 W 0.6 1.1 0 Days
Vols (µl) Times (sec) Limits
Sample 10 2nd Reag 0 Low Conc 0.2
1st Reag 200 Incubation 60 High Conc 15
2nd Reag 0 Interval 120 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum -0.5 Provisory
Replacement
Intercept -0.3 Maximum 0.5 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Iron FS Ferene Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 1911 .. .. …
Notes
1. Please refer to the package insert for Iron FS Ferene for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
IRON Iron DIASYS µg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 600 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 20 2nd Reag 120 Low Conc 2
1st Reag 200 Incubation 600 High Conc 1000
2nd Reag 50 Kinetics2 0 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Alkaline Phosphatase FS IFCC 37°C Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 0441 .. .. …
Notes
1. Please refer to the package insert for Alkaline Phosphatase FS IFCC 37°C for detailed information about the test on
the following: Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
ALP-DI ALP DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 405 M 53 128
Cal. Life time
Bichromatic 0 W 42 98 0 Days
Vols (µl) Times (sec) Limits
Sample 4 2nd Reag 60 Low Conc 2
1st Reag 200 Incubation 60 High Conc 858
2nd Reag 50 Interval 0 Consumption 0.25
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Gamma GT FS (Szasz mod.) Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 2801 .. .. …
Notes
1. Please refer to the package insert for Gamma GT FS (Szasz mod.) for detailed information about the test on the
following: Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
GGT GGT DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 405 M 0 55
Cal. Life time
Bichromatic 0 W 0 38 0 Days
Vols (µl) Times (sec) Limits
Sample 20 2nd Reag 60 Low Conc 2
1st Reag 200 Incubation 60 High Conc 284
2nd Reag 50 Interval 0 Consumption 0.2
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Glucose GOD FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 2500 .. .. …
Notes
1. Please refer to the package insert for Glucose GOD FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
GLUC-DI Glucose DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 550 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 1
1st Reag 300 Incubation 600 High Conc 400
2nd Reag 0 Interval 0 Consumption 0
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 0.3 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
January 2009/4
oneHbA1c FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 3329 .. .. …
Notes
1. Please refer to the package insert for oneHbA1c FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
HbA1c HbA1c DIASYS **
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 650 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 4 2nd Reag 300 Low Conc #
1st Reag 180 Incubation 300 High Conc #
2nd Reag 90 Interval 0 Consumption 0.3
Reference Single point Direction
Single point Factor 1 Increase
Multipoint Standard 0 Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
January 2010/1
HDL-C Immuno FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 3521 .. .. …
Notes
1. Please refer to the package insert for HDL-C Immuno FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
HDL HDL DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Endpoint
Principal 600 M ** **
Cal. Life time
Bichromatic 700 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 300 Low Conc 1
1st Reag 240 Incubation 300 High Conc 180
2nd Reag 60 Kinetics2 0 Consumption 0
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
LDH FS DGKC Autolyzer / MetroLab 2300 – MONOREAGENT APPLICATION
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 4201 .. .. …
Notes
1. Please refer to the package insert for LDH FS DGKC for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
LDH LDH DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 340 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 5
1st Reag 300 Incubation 60 High Conc 3059
2nd Reag 0 Interval 0 Consumption 0.15
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Integrity
Decimals 2
2nd Reag 0 Blank
Temperature 37
Dilution
1: 1
Dilution Exclusive
-
September 2008/1
Lipase DC FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 4321 .. .. …
Notes
1. Please refer to the package insert for Lipase DC FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
LIP-DI Lipase DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 550 M 0 60
Cal. Life time
Bichromatic 0 W 0 60 0 Days
Vols (µl) Times (sec) Limits
Sample 5 2nd Reag 180 Low Conc 2
1st Reag 200 Incubation 90 High Conc 300
2nd Reag 50 Interval 0 Consumption 0.25
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 100 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
June 2009/1
Lp(a) 21 FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 7139 .. .. …
Notes
1. Please refer to the package insert for Lp(a) 21 FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
LPA-DI Lp(a) DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max 2-Pt Kinetics
Principal 700 M 0 30
Cal. Life time
Bichromatic 0 W 0 30 0 Days
Vols (µl) Times (sec) Limits
Sample 5 2nd Reag 0 Low Conc 3
1st Reag 200 Incubation 600 High Conc 130
2nd Reag 100 Interval 240 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 1.0 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Magnesium XL FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 4610 .. .. …
Notes
1. Please refer to the package insert for Magnesium XL FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
MAG-DI Mag DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 550 M 1.8 2.6
Cal. Life time
Bichromatic 0 W 1.8 2.6 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 0
1st Reag 300 Incubation 300 High Conc 5
2nd Reag 0 Interval 0 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
May 2010/1
CRP U-hs High sensitive (hs) application Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 7045 .. .. …
Notes
1. Please refer to the package insert for CRP U-hs for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
CRP CRP DIASYS mg/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max 2-Pt Kinetics
Principal 505 M 0 5
Cal. Life time
Bichromatic 0 W 0 5 0 Days
Vols (µl) Times (sec) Limits
Sample 15 2nd Reag 0 Low Conc 0.05
1st Reag 150 Incubation 600 High Conc 20.0
2nd Reag 150 Interval 240 Consumption 0.3
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 1.0 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Total Protein FS Autolyzer / MetroLab 2300 – MONOREAGENT APPLICATION
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 2311 .. .. …
Notes
1. Please refer to the package insert for Total Protein FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
TP-DI TPROT DIASYS g/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 550 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 4 2nd Reag 0 Low Conc 0.05
1st Reag 200 Incubation 300 High Conc 15
2nd Reag 0 Kinetics2 0 Consumption 0
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 0.2 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 2
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
ASAT (GOT) FS (IFCC mod.) Autolyzer / MetroLab 2300 – MONOREAGENT APPLICATION
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 2601 .. .. …
Notes
1. Please refer to the package insert for ASAT (GOT) FS (IFCC mod.) for detailed information about the test on the
following: Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
ASAT ASAT DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 340 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 30 2nd Reag 0 Low Conc 2
1st Reag 300 Incubation 60 High Conc 349
2nd Reag 0 Interval 0 Consumption 0.16
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Integrity
Decimals 2
2nd Reag 0 Blank
Temperature 37
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
ALAT (GPT) FS (IFCC mod.) Autolyzer / MetroLab 2300 – MONOREAGENT APPLICATION
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 2701 .. .. …
Notes
1. Please refer to the package insert for ALAT (GPT) FS (IFCC mod.) for detailed information about the test on the
following: Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
ALAT ALAT DIASYS U/l
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 340 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 30 2nd Reag 0 Low Conc 4
1st Reag 300 Incubation 60 High Conc 349
2nd Reag 0 Interval 0 Consumption 0.16
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Integrity
Decimals 2
2nd Reag 0 Blank
Temperature 37
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Triglycerides FS Autolyzer / MetroLab 2300
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 5710 .. .. …
Notes
1. Please refer to the package insert for Triglycerides FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
TRIG-DI TRIG DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Color
Principal 550 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 1
1st Reag 300 Incubation 600 High Conc 1000
2nd Reag 0 Interval 0 Consumption 0
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 0.3 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Blank (Color Meth)
Decimals 1
2nd Reag 0 In Cuvette
Temperature 37 Batch
Dilution
1: 1
Dilution Exclusive
-
April 2006/2
Urea FS Autolyzer / MetroLab 2300 – MONOREAGENT APPLICATION
*calculated by the instrument # concentration entered by the user ** entered by the user
Order information Cat. No. 1 3101 .. .. …
Notes
1. Please refer to the package insert for Urea FS for detailed information about the test on the following:
Clinical Relevance, Method and Principle, Composition and Stability of the Reagents, Specimens, Calibrators and Controls, Performance Characteristics regarding Measuring Range / Specificity/Interferences / Sensitivity/Limit of Detection / Precision (Reproducibility, Repeatability) / Method Comparison / Reference Ranges / Literature
2. The stability of the reagent on board the analyser is at least one month provided that contamination and evaporation are avoided.
3. Manufactured by: DiaSys Diagnostic Systems GmbH Alte Strasse 9, 65558 Holzheim, Germany.
**This application proposal is for guidelines only. To avoid misinterpretation measured results have to be validated and assessed with caution.
Test ID Name Brand Units
Urea Urea DIASYS mg/dl
Chemistry
Definition
Wavelength (nm) Reference values Type
Min Max Fast Kinetics
Principal 340 M ** **
Cal. Life time
Bichromatic 0 W ** ** 0 Days
Vols (µl) Times (sec) Limits
Sample 3 2nd Reag 0 Low Conc 2
1st Reag 300 Incubation 40 High Conc 300
2nd Reag 0 Interval 0 Consumption 1.00
Reference Single point Direction
Single point Factor * Increase
Multipoint Standard # Decrease
Detail
Calculation Blank Abs Factor Calculation
Slope 1 Minimum 0 Provisory
Replacement
Intercept 0 Maximum 10 Average
Discard Vol (µl) Additional Shake
Nomencl **
1st Reag 0 Integrity
Decimals 1
2nd Reag 0 Blank
Temperature 37
Dilution
1: 1
Dilution Exclusive