65 melrie - ares ill · 464 melrie 110 110 200 110 110 200 c0 / c180 c90 / c270 cd / 1000 lm 60˚...
Post on 22-Jan-2021
4 Views
Preview:
TRANSCRIPT
463Melrie
MELRIE65
LED VERSION: Class A/A+/A++Luminaire supplied with integrated LED modules that cannot be replaced
A++
A+
AFLUORESCENT VERSION: Class ATC-DEL/G24q-1
A FLUORESCENT VERSION: Class ATC-DEL/G24q-3
AHALOGEN VERSION: Class DQT26/E14
D
EU Regulation 874/2012 - Illumination equipment energy classes
LED VERSION:Class A/A+/A++Luminaire supplied with integrated LED modules that cannot be replaced
.1 White .6 Grey .3 Anthracite .18 Deep Brown.4 Black
• Luminaire for installation on wall – surface mounted.• Configuration: polycarbonate structure and die-cast
aluminium cover and base (MaxiMelrie only), EN AB-47100 alloy (low copper content)
• Double layer coating for high resistance to corrosion: the aluminium components are painted with a double coat using powders that are compliant with QUALICOAT standards: a first layer of epoxy powder (with excellent chemical and mechanical resistance) and a second finishing layer of polyester powder (resistant to UV rays and atmospheric agents). The entire painting process of the aluminium fitting starts from components that have been sandblasted in advance to make the surface more porous and increase the adherence of the paint. Ares effects alkaline and acid washing to clean the surfaces completely, then rinses with demineralised water to remove any residue particles, subsequently a chemical conversion treatment is done to protect against rusting.
• Protection rating: IP65• In compliance with EN 60598-1 standards• Class of insulation: Melrie: II; MaxiMelrie: I• Installation: Melrie: wiring through two rubber cable
holders (5mm<Ø<10mm cables); MaxiMelrie: wiring through two rubber cable holders (8mm<Ø<13mm cables). Outdoor use requires suitable flexible cables assuring the watertightness of the cable holder.
• During the installation and the maintenance of the fixtures it is important to be careful and avoid damages on the paint coating. Damages on the coating exposed to outdoor conditions or water, could cause corrosion.Chemical substances affect the anticorrosion covering protection.
The fitting is equipped with 2 cable input
Protection againstimpact.IK 09 - 10,00 joule
Wall fitting
FLUORESCENT VERSION:Class A TC-DEL/G24q-1TC-DEL/G24q-3
HALOGEN VERSION:Class D QT26/E14
464 Melrie
110
110
200
110
110
200
C0 / C180 C90 / C270
cd / 1000 lm
60˚
30˚
90˚
60
88 23 12 11 0
= 44.0˚+ 29.0˚ = 64.0˚+ 64.0˚
Max Medm1.00
2.003.004.005.00
30
lux lux
C0 / C180 C90 / C270
cd / 1000 lm
1514 46 24 12 1
= 55.0˚+ 26.0˚ = 60.0˚+ 60.0˚
Max Medm1.00
2.003.004.005.00
56
lux lux
60˚
30˚
90˚
60
C0 / C180 C90 / C270
cd / 1000 lm
185 5446 1321 612 37 2
= 43.0˚+ 43.0˚ = 63.0˚+ 63.0˚
Maxlux
Medlux
m1.00
2.003.004.005.00
360
30˚
60˚
90˚
485721 TC-DEL 13W G24q-1
65
65
@4000K
483005White 2700K lm LED 714 ≠ lm OUTPUT 452
483002White 3000K lm LED 768 ≠ lm OUTPUT 486
483001White 4000K lm LED 806 ≠ lm OUTPUT 510
Melrie - Unidirectional
Melrie - Unidirectional
Electronic ballast
Light Source: Mid-Power LED / 5,5W / Total power 8W / CRI>80 / 220÷240V / Integral electronic power supply
481121 QT 26 40W E14Lamp max size: Ø40 mm H.95 mm
465Melrie
110
110
200
C0 / C180 C90 / C270
cd / 1000 lm
185 5446 1321 612 37 2
= 43.0˚+ 43.0˚ = 63.0˚+ 63.0˚
Maxlux
Medlux
m1.00
2.003.004.005.00
200
60˚
90˚
120˚
110
110
200
C0 / C180 C90 / C270
cd / 1000 lm
88 23 12 11 0
= 44.0˚+ 29.0˚ = 64.0˚+ 64.0˚
Max Medm1.00
2.003.004.005.00
30
lux lux
90˚
60˚
120˚ 60
C0 / C180 C90 / C270
cd / 1000 lm
90˚
60˚
120˚ 60
1517 46 24 12 1
= 55.0˚+ 26.0˚ = 60.0˚+ 60.0˚
Max Medm1.00
2.003.004.005.00
56
lux lux485722 TC-DEL 13W G24q-1
65
65
@4000K
483006White 2700K lm LED 2x714 ≠ lm OUTPUT 2x452
483004White 3000K lm LED 2x768 ≠ lm OUTPUT 2x486
483003White 4000K lm LED 2x806 ≠ lm OUTPUT 2x510
Melrie - Bidirectional
Melrie - Bidirectional
Electronic ballast
Light Source: Mid-Power LED / 11W / Total power 14W / CRI>80 / 220÷240V / Integral electronic power supply
481122 QT 26 40W E14Lamp max size: Ø40 mm H.95 mm
466 Melrie
120
140
280
C0 / C180 C90 / C270
cd / 1000 lm
296 8674 2133 1018 512 3
= 43.0˚+ 43.0˚ = 63.0˚+ 63.0˚
Maxlux
Medlux
m1.00
2.003.004.005.00
360
30˚
60˚
90˚
C0 / C180 C90 / C270
cd / 1000 lm
60˚
30˚
90˚
45
3822 910 46 24 2
= 34.0˚+ 34.0˚ = 58.0˚+ 58.0˚
Max Medm1.00
2.003.004.005.00
89
lux lux486121 TC-DEL 26W G24q-3
120
140
280 65
65
4827524White 2700K lm LED 1144 ≠ lm OUTPUT 724
4827521White 3000K lm LED 1230 ≠ lm OUTPUT 778
4827421White 4000K lm LED 1291 ≠ lm OUTPUT 817
@4000K
MaxiMelrie - Unidirectional
MaxiMelrie - Unidirectional
Light Source: Mid-Power LED / 8,8W / Total power 12W / CRI>80 / 220÷240V / Integral electronic power supply
Electronic ballast
Dimmable on request
120
140
280
C0 / C180 C90 / C270
cd / 1000 lm
296 8674 2133 1018 512 3
= 43.0˚+ 43.0˚ = 63.0˚+ 63.0˚
Maxlux
Medlux
m1.00
2.003.004.005.00
200
60˚
90˚
120˚
467Melrie
120
140
280
C0 / C180 C90 / C270
cd / 1000 lm
90˚
60˚
120˚45
3822 910 46 24 2
= 34.0˚+ 34.0˚ = 58.0˚+ 58.0˚
Max Medm1.00
2.003.004.005.00
89
lux lux486122 TC-DEL 26W G24q-3
65
65
4827525White 2700K lm LED 2x1144 ≠ lm OUTPUT 2x724
4827522White 3000K lm LED 2x1230 ≠ lm OUTPUT 2x778
4827422White 4000K lm LED 2x1291 ≠ lm OUTPUT 2x817
@4000K
MaxiMelrie - Bidirectional
MaxiMelrie - Bidirectional
Light Source: Mid-Power LED / 17,6W / Total power 18W / CRI>80 / 220÷240V / Integral electronic power supply
Electronic ballast
Dimmable on request
468 Melrie
469Melrie
65
5030
acc. code
prod. code 237
481121
481122
483001 •483002 •483003 •483004 •483005 •483006 •485721
485722
486121
486122
4827421 •4827422 •4827521 •4827522 •4827524 •4827525 •
Accessories: Melrie
237SPD: (SURGE PROTECTION DEVICE) 275Vac MAXIMUM DISCHARGE CURRENT 10KA (8/20μs) MAXIMUM OPERATING CURRENT 5ASUITABLE FOR SERIES CONNEC-TION - IP66
top related