7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 1/20
Wireless Curriculum Development Section
ISSUE
WG001201 MSOFTX3000
hardware data configuration
1.0
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 2/20
2Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Review
This chapter describes the related concepts and
configuration process of MSOFTX3000 equipment
data, including the configuration of hardware basic
information and board data.
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 3/20
3Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
References
MSOFTX3000 Operation Manual-Data Configuration
MSOFTX3000 Hardware Description Manual
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 4/20
4Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Course Contents
Chapter 1 overview
Chapter 2 hardware configuration
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 5/20
5Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
MSOFTX3000 data configuration procedure
¿ ªÊ ¼
Configuring hardware data
Configuring local office information
Configuring data of interface
Start
Data preparation
Configuring number analysis data
Configuring mobile service data
End
Internal dataconfiguration
Service dataconfiguration
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 6/20
6Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Data configuration Preparation
Command Description
LOF To set offline
SET CWSON: SWT=OFF To disable the alarm switch
SET FMT: STS=OFF To disable the format conversion switchLON To set online
SET CWSON: SWT=ON To enable the alarm switch
SET FMT: STS=ON To enable the format conversion switch
FMT To format data
Power off, power on, and start
loading
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 7/20
7Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Course Contents
Chapter 1 overview
Chapter 2 hardware configuration
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 8/20
8Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Chapter 2 the Chapter Name
2.1 Related Concepts
2.2 Configuration Procedures
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 9/20
9Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
MSOFTX3000 Cabinet
Expansion subrack (9U)
Air deflector (2U)
Power distribution subrack (2U)
Expansion subrack (9U)
Air deflector (2U)
Expansion subrack (9U)
Air deflector (2U)
Expansion subrack (9U)
Air deflector (2U)
Expansion Configuration CabinetIntegrated Configuration Cabinet
Expansion subrack (9U)
Air deflector (2U)
Power distribution subrack (2U)
Expansion subrack (9U)
Air deflector (2U)
Expansion subrack (9U)
Air deflector (2U)
Expansion subrack (9U)
Air deflector (2U)
Expansion Configuration Cabinet
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 10/20
10Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Equipment Numbering
Shelf number:0-2
Frame number:0-9
The service processing frame number is set by the DIP switch of the WSIU of the
frame. (off=1,on=0)
The basic frame is numbered 0 and other frames are numbered 1~9 in bottom-up
order.
Switch
Frame number
8 7 6 5 4 3 2 1
0 on on on on on on on on
1 on on on on on on on off
2 on on on on on on off on
3 on on on on on on off off
4 on on on on on off on on
5 on on on on on off on off
6 on on on on on off off on
7 on on on on on off off off
8 on on on on off on on on
9 on on on on off on on off
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 11/20
11Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Equipment Numbering
Slot number
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
W B
S
G
W C C
U
W C C
U
W B
S
G
W I F
M
W C D
B
W I
F
M
W
C D
B
W M G
C
W
A L
U
U P W
R
U P W
R
W C S
U
W C S
U
W S M
U
W
M G
C
W
H S
C
U P W
R
U P W
R
W W P
I
W E P
I
W
H S
C
W C K
I
W C
K
I
W B F
I
W B F
I
W S IU
W
S
IU
Front
Back
W S M
U
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 12/20
12Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Equipment Numbering
Slot number
WSMU boards (and back-insert board WSIU) must be installed
in slots 6 and 8.
WALU must be installed in front slot 16.
WHSC must be installed in back slots 7 and 9, and blank filter
panels are configured in corresponding front slots.
Each UPWR board occupies two slots, and there are two front
UPWR boards and two back UPWR boards. The slot numbers
designated are 17 and 19 fixedly.
Other slots (0~5, 10~15) are installed with service processing
boards (including WCCU, WCSU, WBSG, WIFM, WAFM,
WCDB, WVDB and WMGC).
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 13/20
13Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Equipment Numbering
Module number
WSMU module number: 2~21 (allocated automatically by the
system)
WCCU/WCSU module number: 22~101
WCDB/WVDB module number: 102~131
WMGC/WAFM/WIFM/WBSG/WSGU module number: 132~211
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 14/20
14Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Chapter 2 the Chapter Name
2.1 Related Concepts
2.2 Configu rat ion Procedures
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 15/20
15Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Procedures for configuring equipment data
Procedure Command
Step 1: Add shelf ADD SHF
Step 2: Add frame ADD FRM
Step 3: Add board ADD BRD
Step 4: Configure functions of WCDB board ADD CDBFUNC
Step 5: Configure E1 port information of WEPI
boardADD EPICFG
Step 6: Configure FE port information of
WIFM board
ADD FECFG
Step 7: Clock configurationSET CKICFG
ADD BOSRC
Step 8: Load equipment data -
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 16/20
16Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Parameter relationship of commands for configuring
equipment data
ADD SHF
[Shelf Number]
[Location Title]
[Position Number]
ADD FRM
[Frame Number]
[Shelf Number]
[Position Number]
ADD BRD
[Frame Number]
[Slot Number]
[Module Number]
[Board Type]
ADD EPICFG
[EPI Frame Number]
[EPI Slot Number]
ADD FECFG
[IFM Module Number]
[IP Address]
ADD CDBFUNC
[CDP Module Number]
[Function]
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 17/20
17Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Locking Clock Reference Source through E1
Procedure Command
Step 1: Adding WEPI and WCKI ADD BRD
Step 2: Configuring clock reference source SET CKICFG
Step 3: Configuring E1 information ADD EPICFG
Step 4: Extracting clock reference data from WEPI ADD BOSRC
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 18/20
18Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Locking Clock Reference Source through BITS
Procedure Command
Step 1: Adding WEPI and WCKI ADD BRD
Step 2: Configuring clock reference source SET CKICFG
Step 3: Configuring E1 information ADD EPICFG
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 19/20
19Confidential Information of Huawei.
No Spreading without Permission. Security Level: Internal
Summary
Master hardware data configuration steps
ADD SHF
ADD FRM
ADD BRD
ADD CDBFUNC
ADD EPICFG
ADD FECFG
Clock configuration
Master hardware data configuration method
7/27/2019 5WG001201 MSOFTX3000 Hardware Data Configuration ISSUE 1.0
http://slidepdf.com/reader/full/5wg001201-msoftx3000-hardware-data-configuration-issue-10 20/20
20Confidential Information of Huawei.
N S di ith t P i i Security Level: Internal
top related