Accessories
278
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
6/08
Flow Limiter
without additional power requirement
saves energy by limiting the flow rate to theactually needed flow
compact design
easy to install
all metal version without plastic internals
materials: brass or stainless steel
SB02
Description
The model SB02 flow limiters are used to limit the flow of
water or waterlike media to a fixed value. They make surethat this fixed flow rate stays constant despite varying
upstream or downstream pressures. Contrary to the
commonly used products of this kind the SB02 limiter do
not utilize a plastic membrane as limiting device. Instead
the SB02 work with a spring loaded stainless steel variable
orifice. Due to the differential pressure across the limiter
this variable orifice changes its aperture continously.
Through increasing the orifice size with falling pressure or
decreasing it with rising pressure the flow rate will always
remain constant.
Applications
For water and waterlike media.
Usable in water distribution systems in the industry, in carwash installations, for sanitary applications and in water
treatment systems.
-
7/29/2019 190 - 207.pdf
2/18279
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
Ordering code:
Order number SB02. 1. 1. 10. 0
Flow limiter
Process connection:
1 = G 1/2 female on both sides
1N = 1/2" NPT female on both sides
2 = G 3/4 female on both sides
2N = 3/4" NPT female on both sides3 = Input G 1/2 female, output G 1/2 male
3N = Input 1/2" NPT female, output 1/2" NPT male
4 = Input G 3/4 female, output G 3/4 male
4N = Input 3/4" NPT female, output 3/4" NPT male
Materials:
1 = brass
2 = stainless steel
Flow rate:
xx = flow rate in GPM or l/min
Options:
0 = without
1 = please describe
Model L GT GL GI GA SW
SB02.1 43 14 1/2" 24
SB02.2 45 15 3/4" 30
SB02.3 43 14 14 1/2" G 1/2 24
SB02.4 45 15 15 3/4" G 3/4 30
Technical specifications:
min. control pressure: 29 psi / 2 bar
max. differential pressure: 145 psi / 10 bar
max. static pressure: 928 psi / 64 bar
max. temperature: 392 F / 200 C
accuracy:
up to 2 l/min 15 % from actual flow value
from 3 l/min 10 % from actual flow value
Dimensions:
Versions:
Process connection:
1/2" NPT or G 1/2 female on both sides
3/4" NPT or G 3/4 female on both sides
Input 1/2" NPT or G 1/2 female, output 1/2" NPT
or G 1/2 male
Input 3/4" NPT or G 3/4 female, output 3/4" NPT or
G 3/4 male
Materials:
Housing brass, internals stainless steel
Housing and internals stainless steel
Flow rates:
from 0.264-7.925 GPM / 1-30 l/min water in steps of 0.264
GPM / 1 l/min, and 10.5 GPM / 40 l/min
The flow rates are defined by the design of the units and
cannot be changed by the user.
By installing several single SB02 in parallel almost allrequired flow rates may be achieved (see data sheet SB03).
Principle of operation:
The orifice size decreases proportional to the upstream
pressure , therefore the flow rate remains constant.
fixed orifice
flow limiter SB02
bar
1) housing
2) ring
3) variable orifice
4) fixing ring
-
7/29/2019 190 - 207.pdf
3/18
Accessories
280
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
6/08
Flow Limiter For LargeFlow Rates
without additional powerrequirements
saves energy by limiting the flowrateto the actually needed flow
for pipe diameters (DN 20...DN80)
with male thread for mouting intoexisting pipes or completewith flowhousing
all metal version without plasticinternals
materials: brass or st. steel
SB03
Description:
The model SB03 flow limiters are used to limit the flow of
water or waterlike media to a fixed value. They makesurethat this fixed flow rate stays constant despite varying
upstream or downstream pressures. Contrary to the com-
monly used products of this kind the SB03 limiter do notuti-lize a plastic membrane as limiting device. Instead the SB03
work with a spring loaded stainless steel variableorifice. Due
to the differential pressure across the limiter this variable ori-
fice changes its aperture continously. Through increasing the
orifice size with falling pressure or decreasing it with rising
pressure the flow rate will always remain constant.
Applications:
For water and waterlike media. Usable in water distribution
systems in the industry, in carwash installations, for sanitaryapplications and in water treatment systems.
-
7/29/2019 190 - 207.pdf
4/18281
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
Ordering code
Order no. SB03. 1. 50. 100
Flow limiter
Disc material:
1 = Scheibe Messing, Einstze Edelstahl
2 = Scheibe Edelstahl, Einstze Edelstahl
Disc outer diameter:
20 = G 3/4
40 = G 1 1/250 = G 2
65 = G 2 1/2
80 = G 3
Flow rate:
xxx = in l/min. water
D max. no. flow rate
Disc size of limiting (l/min.)
(male thread G) elements
3/4 1 1-30
1 1/2 3 3-90
2 5 5-150
2 1/2 9 9-270
3 13 13-390
Technische Daten
min. regulating pressure: 2 bar
max. differential pressure: 10 bar
max. static pressure: 16 bar
max. temperature: 100 C
materials:
disc: brass or st. steel 1.4571
insert: st. steel 1.4310
ring: st. steel 1.4310
Principle of operation
see data sheet SB02
Flow rates
Single limiting elements may be supplied for the following
flow rates: 130 l/min water. By adding several flowelements onto a common disc nearly all flow rates may be
realized.
Versions and dimensions
The SB03 flow limiters are available either as disc
with male thread (G) or mounted into a st. steel
flow housing
H = 12 mm
-
7/29/2019 190 - 207.pdf
5/18
Accessories
284
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
8/08
SF01Y-strainer with magneticseparator
for 1/4" to 3" piping systems
mesh size 0.02" or 0.01" /0.6 or 0.25 mm
compact design
red bronze, brass andstainless steel models available
Description:
Model SF01 Y-strainers are designed to protect devices in-
stalled in the pipe system from damage from contaminants
in the gas / liquid being monitored. In particular, measuring
devices with magnetic components can be protected by
the filters with magnetic separators from interference from
ferrite particles.
Typical Applications:
For liquids, gases and vapors to 300 F / 150 C.
For water, petroleum, gear unit oil, heating oil and hydraulic
oil etc. For protecting pumps, gear units and flow meters.
-
7/29/2019 190 - 207.pdf
6/18285
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
Models
Versions:
with magnetic separator
for pipe systems von 1/4" to 3",
mesh size 0.02" / 0.6 mm
Materials:
red bronze, brass and stainless steel
Technical Specifications:
Max. temperature: 300 F / 150 C
Materials:
Housing: red bronze, brass, stainless steel
Mesh: stainless steel
Magnet system: ferrite
Ordering Code
Order Number: SF01. 2. 1. 3. 1.
Y-strainer
Model:
2 = with magnetic separator
Material:
1 = red bronze (for sizes 1/4" to 2" only)
2 = brass (for sizes 2 1/2" and 3" only)3 = stainless steel (for sizes 1/2" to 2" only)
Connection:
2 = G 1/2 female
3 = G 3/4 female
4 = G 1 female
5 = G 1 1/4 female
6 = G 1 1/2 female
7 = G 2 female
8 = G 2 1/2 female
9 = G 3 female
Mesh size:1 = 0.02" / 0.6 mm (standard)
Dimensions:
Model D L t H A/F SW1 A/F SW2
(G thread) ( inch / mm) (inch / mm) (inch / mm) (inch / mm) (inch / mm)
SF01.2.x.0 1/4" 2.20 / 56 0.43 / 11 1.38 / 35 0.83 / 21 0.67 / 17
SF01.2.x.1 3/8" 2.20 / 56 0.43 / 11 1.38 / 35 0.83 / 21 0.67 / 17
SF01.2.x.2 1/2" 2.52 / 64 0.47 / 12 1.65 / 42 0.89 / 25 0.87 / 22
SF01.2.x.3 3/4" 2.95 / 75 0.55 / 14 1.97 / 50 1.22 / 31 1.06 / 27
SF01.2.x.4 1" 3.54 / 90 0.59 / 15 2.44 / 62 1.50 / 38 1.26 / 32
SF01.2.x.5 1 1/4" 4.41 / 112 0.71 / 18 3.07 / 78 1.85 / 47 1.61 / 41SF01.2.x.6 1 1/2" 4.72 / 120 0.71 / 18 3.23 / 82 2.13 / 54 1.81 /46
SF01.2.x.7 2" 5.91 / 150 0.87 / 22 3.74 / 95 2.60 / 66 2.20 / 56
SF01.2.x.8 2 1/2" 8.66 / 220 0.91 / 23 4.92 / 125 3.35 / 85 2.76 / 70
SF01.2.x.9 3" 9.57 / 243 1.02 / 26 5.51 / 140 3.94 / 100 2.95 / 75
-
7/29/2019 190 - 207.pdf
7/18
Accessories
286
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
8/08
SF02Fine filters for liquidsand gases
for 1/8" to 3/4" pipe systems
filter elements: 5 - 300 m
fil ter cup made of PPor transparent nylon
filter element easy to clean
Description:
Model SF02 fine filters consist of the filter head made of
polypropylene, the filter cup made of PP or transparent nylon
and different filter elements made of sintered plastic or
stainless steel. The filter cup can be easily unscrewed to
remove the filter element for cleaning.
Typical Applications:
For cleaning liquids and gases where devices installed
in the piping system must be protected from foreign objects
and debris.
-
7/29/2019 190 - 207.pdf
8/18287
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
Ordering Code
Bestellnummer SF02. L. 1 P. 3. N
fine filters
Model:
K = short filter, d = 0.71 / 18 mm
(for 1/8 - 1/2 only)
L = long filter, d = 0.71 / 18 mm
(for 1/8 - 1/2 only)
G = large filter, d = 1.1 / 28 mm
(for 3/8 - 3/4 only)
Process connection:
1 = Rp 1/8 female thread
2 = Rp 1/4 female thread
3 = Rp 3/8 female thread
4 = Rp 1/2 female thread
5 = Rp 3/4 female thread
Filter cup material:
P = polypropylene
N = transparent nylon
Filter element:
1 = 5 m, sintered plastic
2 = 35 m, sintered plastic
3 = 80 m, sintered plastic
4 = 50 m, stainless steel
5 = 100 m, stainless steel
6 = 300 m, stainless steel
Gasket:
N = NBR
E = EPDM
V = Viton
Models
SF02.K: short filter for slightly dirty
or lightly contaminated gases/liquids
SF02.L: long filter for dirty
or contaminated gases/liquids
SF02.G: large filter for very dirty
or badly contaminated gases/liquids
Dimensions
Technical Specifications
Operating temperature: max. 125 F / 52 C
System pressure: 145 psi at 75 F / 10 bar at 24 C
100 psi at 125 F / 7 bar at 52 C
Materials:
Housing: polypropylene
Filter cup: polypropylene or
transparent nylon
Filter element: sintered plastic
UHMW-PE or stainless steel
Gasket: NBR / EPDM / Viton
Model Female H L D X weight
thread (inch / (inch / (inch / (inch / (lbs. / g)
(Rp) mm) mm) mm) mm)
SF02.K.1 1/8" 1.97 / 50 3.03 / 77 1.91 / 48.5 0.75 / 19 0.11 / 50
SF02.L.1 3.31 / 84 3.03 / 77 1.91 / 48.5 0.75 / 19 0.17 / 75
SF02.K.2 1/4" 0.97 / 50 3.03 / 77 1.91 / 48.5 0.75 / 19 0.11 / 50
SF02.L.2 3.31 / 84 3.03 / 77 1.91 / 48.5 0.75 / 19 0.17 / 75
SF02.K.3 2.13 / 54 3.03 / 77 1.91 / 48.5 0.75 / 19 0.14 / 65
SF02.L.3 3/8" 3.46 / 88 3.03 / 77 1.91 / 48.5 0.75 / 19 0.21 / 95
SF02.G.3 4.49 / 114 3.58 / 91 2.95 / 75 0.79 / 20 0.39 / 175
SF02.K.4 2.13 / 54 3.03 / 77 1.91 / 48.5 0.75 / 19 0.14 / 65
SF02.L.4 1/2" 3.46 / 88 3.03 / 77 1.91 / 48.5 0.75 / 19 0.17 / 80
SF02.G.4 4.49 / 114 3.58 / 91 2.95 / 75 0.79 / 20 0.37 / 170
SF02.G.5 3/4" 4.69 / 119 3.58 / 91 2.95 / 75 0.79 / 20 0.42 / 190
-
7/29/2019 190 - 207.pdf
9/18
Accessories
288
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
/08
Needle valves made of brass
or carbon steel
Nominal pressures PN100 and PN 200
Liquid temperatures to 350 C
Process connection from G 1/8 to G 2
Wetted parts made of brass or carbonsteel, plastic or graphite packing
SNV01
Description:
PKP needle valves in model series SNV01 accurately
regulate the flow of liquids in piping systems.
The devices are designed in two parts, the upper part
is screwed into the base and is sealed with plastic or
graphite packing.
Applications:
PKP needle valves are designed to shut off, reduce
and regulate flowing liquids in industrial plant.
The devices are ideally suited for use as shut-off valves
in flow and level measurement applications.
-
7/29/2019 190 - 207.pdf
10/18289
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
Technical details:
Materials:
SNV01.G.1.1: brass body
buna N packing
(G 1/8 to G1/2), orPTFE (G 3/4 to G2)
SNV01.G.1.2: carbon steel body 9 S 20 K
stainless steel stem
1.4104
graphite packing
Max. pressure:
SNV01.G.1.1: 100 bar
SNV01.G.1.2: 200 bar
Max. temperature:
SNV01.G.1.1: 100 C
SNV01.G.1.2: 350 C
Model Coding:
Order number: SNV01. G. 1. 1. 15. 0
SNV01 needle valve
Design:
G = G screw thread
Process connection:
1 = female thread on both sides
Material:
1 = brass, PN100
2 = carbon steel, PN200
Nominal pipe size:
06 = 1/8
08 = 1/4
10 = 3/8
15 = 1/2
20 = 3/4
25 = 1
32 = 1 1/4"
40 = 1 1/2"
50 = 2
Options:
0 = none
9 = custom version, please specify in writing
PN100, brass PN200, carbon steel
brass, PN100
1/8 50 70 12,5
1/4 50 78 12,5
3/8 50 78 12,5
1/2 55 78 14
3/4 67 90 18
1 75 95 22,5
11/4 110 105 30
11/2 110 110 32,5
2 110 110 32,5
carbon steel, PN200
1/8 50 72 12
1/4 50 72 12
3/8 55 72 12
1/2 60 77 14
3/4 75 97 17
1 100 110 22
1 1/4 110 145 28
1 1/2 130 145 33
2 130 145 33
Dimension (mm)
L H M
Process connection
G
Designs:
SNV01.G: thread connection G,
to DIN / ISO 228
Nominal pressures:
SNV01.x.x.1: PN100 (brass design only)
SNV01.x.x.2: PN200 (carbon steel design only)
Dimension:
-
7/29/2019 190 - 207.pdf
11/18
Accessories
290
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
8/08
Needle valves made of
stainless steel,
high-pressure version
Max. pressure 3600 psi or 5800 psi /250 or 400 bar
Medium temperatures to 480 F / 250 C
For nominal pipe sizes from 1/8 to 2
Process connection G or NPT
Wetted parts made of stainless steelAIS 316 Ti / 1.4571, packing made ofPTFE or graphite
SNV02
Description:
PKP needle valves model SNV02 accurately regulate the
flow of liquids in piping systems.
The devices are designed in two parts, the upper part
is screwed into the base and is sealed with PTFE or
graphite packing.
Applications:
A variety of versions are available in stainless steel
AIS 316 Ti / 1.4571 for nominal sizes 1/8 to 2 G or NPT
screw threads, and for two nominal pressures (3600 psi or
5800 psi / 250 or 400 bar). These device versions can be
deployed in a wide range of applications.
-
7/29/2019 190 - 207.pdf
12/18291
PKP Process Instruments Inc.
10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbH
Borsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
Dimension (inch / mm)
Designs:
SNV02.G: thread connection G,to DIN / ISO 228
SNV02.N: thread connection NPT,
to ANSI / ASME B1.20.1-1983
Nominal pressures:
SNV02.x.x.1: 3600 psi / 250 bar
SNV02.x.x.2: 5800 psi / 400 bar
Dimension:
Ordering Code:
Order number: SNV02.
SNV02 needle valve made of stainless steel
Design:
G = G screw thread
N = NPT screw thread
S = custom connection
Process connection:
1 = female thread at both sides
2 = female/male thread
3 = male thread at both sides
Max. pressure:
1 = 3600 psi / 250 bar
2 = 5800 psi / 400 bar
9 = custom version
Nominal pipe size:
06 = 1/8
08 = 1/4
10 = 3/815 = 1/2
20 = 3/4
25 = 1
32 = 1 1/4
40 = 1 1/2
50 = 2
Options:
0 = none
2 = high-temperature design up to 480 F / 250 C
9 = custom version, please specify in writing
3600 psi / 250 bar 5800 psi / 400 bar
3600 psi / 250 bar
1/8" 1,77 / 45 1,97 / 50 2,91 / 74 1,97 / 50
1/4" 1,97 / 50 2,17 / 55 2,87 / 73 1,97 / 50
3/8" 2,17 / 55 2,36 / 60 2,83 / 72 1,97 / 50
1/2" 2,36 / 60 2,56 / 65 3,27 / 83 2,48 / 63
3/4" 2,95 / 75 3,15 / 80 3,94 / 100 2,48 / 63
1" 3,94 / 100 4,13 / 105 4,33 / 110 3,15 / 80
1 1/4" 4,72 / 120 4,92 / 125 5,31 / 135 3,94 / 100
1 1/2" 5,12 / 130 5,31 / 135 5,51 / 140 3,94 / 100
2" 6,3 / 160 6,5 / 165 5,91 / 150 3,94 / 100
5800 psi / 400 bar
1/8" 2,17 / 55 2,36 / 60 3,7 / 94 1,97 / 501/4" 2,36 / 60 2,56 / 65 3,66 / 93 1,97 / 50
3/8" 2,95 / 75 3,15 / 80 3,62 / 92 1,97 / 50
1/2" 3,94 / 100 4,13 / 105 3,78 / 96 2,48 / 63
3/4" 4,72 / 120 4,92 / 125 4,25 / 108 2,48 / 63
1" 5,12 / 130 5,31 / 135 4,84 / 123 3,15 / 80
Process connectionL screw L screw H D
thread thread
G NPT
Technical details:
Materials:
body: stainless steel AISI 316 Ti / 1.4571
packing: standard up to 212 F / 100 C: PTFE
high-temperature up to 250C:
graphite
Max. pressure: 3600 psi or 5800 psi /
250 or 400 bar
as per Ordering Code
max. temperature: standard: 212 F / 100 Chigh-temperature: 480 F / 250 C
Special versions
Compression fitting (coupling) to DIN 2353, series S and L
Clamping tapered ring screw joints
Non-standard sizes up to 4 Maximum pressure version up to 9100 psi / 630 bar
upon request
G. 1. 1. 15. 0
-
7/29/2019 190 - 207.pdf
13/18
Accessories
PKP Process Instruments Inc.10 Brent Drive Hudson, MA 01749
1 +1-978-212-0006 2 +1-978-568-0060
Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbHBorsigstrae 24 D-65205 Wiesbaden
1 +49 (0) 6122-7055-0 2 +49 (0) 6122-7055-50
Email: info@pkp.de Internet: www.pkp.de
Analog transmitter for use
with models DS02DS08
flow sensors and switches
U i>i`Vi>}i(420 mA or 0 10 V)
U i`}>>LiVi`
U "i>}ii>iv20Cto +70C
U }iiV>}iVV>L
DSxx...A
Description:
Model DSxx...A analog transmitters can be used in conjunc-
tion with the following models of flow sensors and switches:
DS02, DS04, DS06 and DS08. The DSxx...A transmitter gen-
erates an analog output signal corresponding to the flow rate
of the medium being monitored. This signal can be used for
various measurement and control operations. Furthermore,
models DSxxA.2 and A.3 are fitted with a transistorized
switched output that can be field-programmed directly on
site. This transmitter is a very reliable accessory device with
high repeatability.
Typical Applications:
Model DSxx...A analog transmitters must only be used in
conjunction with flow-measurement and flow-monitoring
devices listed on the reverse side of this data sheet.
8/10
-
7/29/2019 190 - 207.pdf
14/18
PKP Process Instruments Inc.10 Brent Drive Hudson, MA 017491 +1-978-212-0006 2 +1-978-568-0060
Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbHBorsigstrae 24 D-65205 Wiesbaden
1 +49 (0) 6122-7055-0 2 +49 (0) 6122-7055-50
Email: info@pkp.de Internet: www.pkp.de
Model Coding:
7/10
Models:
DSxxA.1: Current or voltage output
DSxxA.2: Current or voltage output + 1 MIN contact
DSxxA.3: Current or voltage output + 1 MAX contact
DSxxA.1:
DSxxA.2:
V>L>"\
Dimensions:
Electrical Connection:
/iVV>-iVvV>\
Analog output: 4 to 20 mA (max. load = 500 Ohm)
0 to 10 V (Imax
= 10 mA)
Switched output: Push/pull transistor, NPN or PNP
TEACH-IN programming by means
of supplied magnet
Hysteresis: 2 % F.S.
Accuracy: See table in section Application/
Combination Options
Reproducibility: 1% F.S.
Power supply: 18 to 30 VDC
Power consumption
max.: < 1 W
Temperature range,
ambient: 20+70 C
Construction of electronics housing:
A.1: Brass, nickel-plated
A.2/A.3: Stainless steel 1.4305
Electrical
connection: Round plug connector, M12x1, 4-pin
Protection type: IP67
Order Number: DSxxA. 1. I.
Analog transmitter for DSxx
(xx = order number of basic unit)
Model features:
1 = Analog output
2 = Analog output and + 1 MIN contact
3 = Analog output and + 1 MAX contact
Output signals:
I = 4 to 20 mA
V = 0 to 10 VModel
Measuring Ranges:
Measurement
accuracy for water
and similar liquids:
3 % F.S.
Measurement
accuracy for air:
10 % F.S.
Measurement
accuracy for
viscous liquids:
5 % F.S.
DS02 W101W3150 L1002L30650
DS04 WA01WA07 LA01LA08
DS06 0114
DS08 0117, 12A17A
DSxxA.1:
DSxxA.2/A.3:
-
7/29/2019 190 - 207.pdf
15/18
-
7/29/2019 190 - 207.pdf
16/18307
Models:
AZ10.I: Counter and Tachometer
LED display: 6-place, 14 mm high
Inputs:
2 independent counter inputs; 1 tachometer,
programmable for input A or B
1 internal counter, programmable A+B, A-B or
along with serial interface for alphanumeric
display of short texts
1, 2 or 4 phase discriminator(s)
Input signals:
NPN, PNP, TTL, floating contacts, setting by
means of DIP switch Maximum input frequency
dependent on counting mode: up to 34 kHz
3 programmable control inputs, NPN or PNP
switching
Output signals:
Pulse output, NPN open collector, freely scala
ble Sensor supply, 12 VDC, 100 mA max.,
short-circuit proof
Power supply:
85250 VAC, 50/60 Hz, 18 VA or1136 VDC, 18 W / 24 VAC, 15 VA
AZ10.P: Display for standard signals
LED display: 5-place, 14 mm high
Freely programmable
Counter, freely programmable
16-point linearization
Inputs:
1 input for analog signals 0 (4)20 mA
or 010 V
3 programmable control inputs, NPN
or PNP switching
Output signals:Sensor supply, 24 VDC, 50 mA max.
Power supply:
85250 VAC, 50/60 Hz, 15 VA or
1136 VDC, 11 W / 24 VAC, 15 VA
AZ10.T: Display for temperature sensors
LED display: 5-place, 14 mm high
Freely programmable for thermocouples
PT-100, resistance thermometer
16-point linearization
Inputs:
1 input for a thermocouple or PT-100
3 programmable control inputs, NPNor PNP switching
Output signals:
Sensor supply, 24 VDC, 50 mA max.
Power supply:
85250 VAC, 50/60 Hz, 15 VA or
1136 VDC, 11 W / 24 VAC, 15 VA
Options
Model series AZ10 devices can be fitted with up three
different output cards.
The cards can be simply inserted into the available slots
and programmed by means of the front keypad or the op-
tional Windows software. If necessary, these cards can be
added later by the customer.
Limit switches:
4 different output cards are available for programminglimit switches:
K2R: 2 relay outputs, changeover contact,
max. 5 A at 230 VAC
K4R: 4 relay outputs, NO contact, max.
3 A at 250 VAC
K4TN: 4 transistor switching outputs,
NPN open collector, max. 100 mA
K4TP: 4 transistor switching outputs,
PNP open collector, max. 100 mA
with external power supply
Analog output:A: Analog output, freely programmable,
0(4)20 mA, 010 V, scalable,
max. load 500 ohm
Interfaces:
RS2: RS-232 interface, half duplex, programmable,
max. 32 devices per loop
RS4: RS-485 interface, mult ipoint, programmable,
max. 32 devices per loop
RPB: Profibus DP interface
PKP Process Instruments Inc.10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbHBorsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
-
7/29/2019 190 - 207.pdf
17/18
1/08
308
Dimensions:
AZ10.I: Front View, Dimensions and Panel Cutout
Model Coding:
Order Number AZ10. P. 1. K2R. RLC
Digital Display and Control Unit
Model:
I = for pulse inputs
P = for analog outputs
T = for temperature sensors
Power supply:
1 = 85 to 250 VAC
2 = 11 to 36 VDC / 24 VAC
Interface cards:
(up to three different cards may be selected)
K2R = 2 relay outputs, changeover contact
K4R = 4 relay outputs, NO contact
K4TN = 4 transistor switching outputs, NPN OC
K4TP = 4 transistor switching outputs, PNP OC
A = Analog output
RS2 = RS-232 interface
RS4 = RS-485 interfaceRPB = Profibus DP interface
Options:
(more than one may be selected)
IP = IP-65 housing
E = Reference sheets for AZ10.P/T
RLC = RLCPro programming software
KIT = Starter kit consisting of RLCPro software,
RS-232 interface card and connection cable
Options
IP-65 housing:
A rugged sheet metal housing is available for model series
AZ10. This housing provides protection against intrusion of
water and dust (protection type IP 65). The housing can be
used on a table top or be installed alongside other equip-
ment. The mounting bracket required is supplied with the
housing.
The rear panel of the housing can be removed to gain ac-
cess to electrical connections. To ensure that the stated
protection type is maintained, any leads installed must be
routed through appropriate cable fittings (not included).
Dimensions (WxHxD): 140 x 83 120 mm
Reference sheets for AZ10.P/T:
Printed reference sheets listing common units used in pro-
cess technology, intended to be stored behind the front co-
ver, are available for the AZ10.P or AZ10.T.
AZ10.P / T: Front View, Dimensions and Panel Cutout
PKP Process Instruments Inc.10 Brent Drive Hudson, MA 01749
S +1-978-212-0006 T +1-978-568-0060Email: info@pkp.eu Internet: www.pkp.eu
PKP Prozessmesstechnik GmbHBorsigstrae 24 D-65205 Wiesbaden
S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50Email: info@pkp.de Internet: www.pkp.de
-
7/29/2019 190 - 207.pdf
18/18
Delivery and Payment TermsPKP Prozessmesstechnik GmbH, Wiesbaden
These business terms have been translated into English from the original German business terms. Only the original German business terms are legally binding.
I. General area of application
1. These business terms apply to all current and future business relations with the entrepreneur.
2. Entrepreneurs under the terms of these business terms are natural or legal persons or partnerships having legal capacity with whom business relations are entered that constitute the exercise
of a trade or self-employed profession.
3. Deviating, contrary or supplementary general business terms, even if known, shall not be part of the contract, unless the validity of such terms is expressly agreed in writing.
4. All delivered goods are produced in accordance with the specifications of the entrepreneur.
II. Conclusion of contract, delivery terms
1. Our offers are subject to confirmation. Subject to technical changes and changes in form, color and/or weight within reason.2. When he orders goods, the entrepreneur makes a binding declaration that he wishes to purchase the goods ordered.
3. We are entitled to accept the contractual offer contained in the order within four weeks of receiving it. Acceptance can be declared in writing or through the delivery of the goods to the entrepreneur.
4. A contract is concluded with the proviso that we are supplied correctly and promptly by our own suppliers. This only applies in the event that failure to deliver is not our responsibility,
in particular when a congruent covering transaction is agreed with out suppliers.
5. The entrepreneur will be notified immediately when a service is unavailable. The remuneration will be returned immediately.
6. The regulations of the Association of German Electro-engineers (VDE) shall apply to all deliveries and services, insofar as these arise in relation to the security of the deliveries or services.
Deviations are permitted insofar as the same security is guaranteed in another way. We reserve unrestricted ownership and copyright utilization rights for down payments, drawings and other
documents. These may only be made available to third parties after separate agreement has been obtained from us. Drawings and other documents that are sent with offers are to be returned
immediately on request if a contract is not concluded.
III. Reservation of ownership
1. We reserve ownership of the goods until the complete settlement of all claims from an ongoing business relationship.
2. The entrepreneur is obliged to handle the goods with care. Insofar as maintenance and inspection work is required, the entrepreneur must carry these out at regular intervals at his own expense.
3. The entrepreneur is obliged to inform us immediately if a third party has access to the goods, for example in the event of the seizure of property or any damage or destruction of the goods .
4. If the entrepreneur violates the contract, in particular default of payment or infringement of an obligation as set down in items 2 and 3 of these provisions, we are entitled to withdraw from the contract
and to demand the return of any property.
5. The entrepreneur is entitled to sell on the commodity in an orderly business process. He hereby transfers to use all claims that accrue to him against a third party through resale, to the amount
identified in the invoice. We accept this transfer. After transfer, the entrepreneur is entitled to collect on the claim. We reserve the right to collect the claim itself as soon as the entrepreneur failsto fulfill his payment obligations in an orderly way and falls in default of payment.
6. The finishing and processing of the goods are always carried out on our behalf and at our request. If processing is carried out with objects that do not belong to us, then we shall acquire co-ownership
of the new item in the ratio of the value of the commodity supplied by us to the other processed objects. The same shall apply if the goods are mixed with other objects that do not belong to us.
IV. Remuneration
1. The offered purchasing price is subject to confirmation. The purchasing price is purely a net price. The legal rate of purchase tax and packaging costs shall apply in addition. In the case of sale by
delivery to a place other than the place of performance, carriage costs and packing costs shall be added to the purchasing price. The entrepreneur shall not be liable for additional costs if orders are
made using telecommunication media. The entrepreneur can pay the purchasing price either cash on delivery or by invoice.
2. The entrepreneur undertakes to pay the purchasing price within 30 days of receiving the goods. The entrepreneur shall be deemed to be in default after this deadline expires.
The entrepreneur must pay interest at 8% above the base interest rate on the debt while in default. We reserve the right to provide evidence of higher damage due to delay and to pursue compen-
sation for such damage.
3. The entrepreneur is entitled to offset payments only if his counter claims have been established by law or accepted by us. The entrepreneur can only exercise the right to retain payment if his
counter-claim is based on the same contractual relationship.
V.Transfer of risk, transport insurance
1. The risk of the accidental perishing and deterioration of the goods shall be transferred to the purchaser upon handover, or, in the case of sale by delivery to a place other than the place of performan-
ce, upon delivery of the goods to the shipping company, freight business or other person or organization entrusted with the transport task.2. The transfer applies equally even if the purchaser delays accepting the goods.
3. Transport insurance will be arranged on the written request of the entrepreneur and shall be at the entrepreneurs expense.
VI. Warranty
1. In the event of a defect in the goods, we shall offer rectification of defects or replacement as we see fit.
2. If the rectification of defects fails, the entrepreneur can always demand a lowering of the remuneration (reduction) or a reversal of the contract (withdrawal). The entrepreneur has no right of withdrawal
in the case of only minor contractual infringements, in particular only minor defects.
3. The entrepreneur must notify us in writing of obvious defects within two weeks of receipt of the goods, otherwise the warranty entitlement cannot be pursued. The date on which the notification is
mailed shall determine the observance of the deadline. The entrepreneur is responsible for providing all proof of all claim requirements, in particular for the defect itself, for the timing of when the
defect was detected and for the prompt issuing of the notice of defect.
4. If the entrepreneur chooses to withdraw from the contract because of a legal or material defect after the rectification of the defect has failed, he shall not have any entitlement to compensation
for the defect. If the entrepreneur chooses compensation after the rectification of the defect has failed, the goods shall remain with the entrepreneur if this is deemed reasonable. Compensation shall
be limited to the difference between the purchasing price and the value of the faulty goods. This shall not apply if we have violated the contract with malicious intent.
5. The warranty period for the entrepreneur is one year from the delivery of the goods. This does not apply if the entrepreneur fails to notify us of the defect in good time (item 3 of these provisions).
6. The product description set down in writing in the offer shall have priority as specifying the composition of the goods; if there is no such description, the product description in the catalog shall provide
the relevant specifications. The right to make technical developments is always reserved and such developments do not imply defects. Public statements, endorsements or advertisements by the
manufacturer do not constitute contractual specifications for the goods.
7. If the entrepreneur receives an incorrect assembly instruction manual, we are only obliged to supply an error-free assembly instruction manual; even this only applies if the error in the assembly instruc-
tions prevent correct assembly.
VII. Limitations of liability
1. In the event of minor breaches of duty, our liability shall be limited to the foreseeable, immediate average damage typical of the contract in accordance with the type of goods. The same shall apply
in cases of minor negligence on the part of our legal representatives or agents. Liability as a result of incorrect storage, incorrect forwarding or incorrect utilization of the goods supplied by us or
as a consequence of failure to comply with the safety information and regulations as well as directives is excluded, as is liability for consequences following the changing or processing of the goods
supplied by us by a third party or in the event of consequences arising from the combination of our goods with foreign products not expressly permitted by us.
2. No liability is accepted for the infringement of minor contractual obligations due to negligence.
3. The afore-mentioned liabilities claims do not relate to claims by the entrepreneur derived from product liability. Furthermore, the liability restrictions do not apply to physical injuries or damage to health
that can be attributed to us or to loss of life.
4. Compensation entitlements accruing to the entrepreneur due to a defect shall expire one year after the goods have been delivered. This does not apply if we can be charged with malicious intent.
VIII. Data protection
The entrepreneur agrees that personal data shall be stored for internal purposes, insofar as this is necessary within the parameters of the purposes of the contractual relationship.
IX. Final provisions
1. German law shall apply. The provisions of the UN Convention on Sales shall not apply.
2. The exclusive court of jurisdiction for all disputes arising from this contract is our place of business. The same shall apply if the entrepreneur does not have a general court of jurisdiction in Germany
or if this court of jurisdiction is not known at the time when an action is commenced.
3. If individual provisions of the contract with the entrepreneur, including these general terms of business, are or become wholly or partly invalid, this shall not affect the validity of the remaining
provisions. The wholly or partially invalid provision should be replaced by a provision that reflects as closely as possible the economic intent of the invalid provision.
4. No oral subsidiary agreements have been reached. Changes to the contract must be made in writing in order to gain validity.
top related