³ ´ ³ - idaho
Post on 12-Nov-2021
5 Views
Preview:
TRANSCRIPT
”
“” “
”
” ””
.
STORM WATER
SPRINKLER PIPE
ST
SP
SANITARY DRAIN
DOMESTIC HOT WATER RECIR. (HWR)
DOMESTIC HOT WATER (HW)
DOMESTIC COLD WATER (CW)
SANITARY VENT
SAN
V
HW
CW
HWR
G
SPRINKLER HEAD
FLEXIBLE-CONNECTION
STRAINER WITH
BLOW OFF VALVE
TP
RELIEF VALVE
TEMPERATURE AND PRESSURE
RELIEF/SAFETY VALVE
GAS PRESSURE REGULATOR
GAS COCK
SOLENOID VALVE
GLOBE VALVE, ANGLE
THREE WAY CONTROL VALVE
TWO WAY CONTROL VALVE
VALVE IN RISE OR DROP
SWING CHECK VALVE
LIFT CHECK VALVE
GATE VALVE, ANGLE
BALL VALVE
GLOBE VALVE
PLUG VALVE
VALVE (PRV)
BUTTERFLY VALVE
PRESSURE REDUCING
GATE VALVE
(REDUCED ZONE)
WALL CLEAN OUT
CO
CO
BACKFLOW PREVENTOR
WATER HAMMER ARRESTER
CIRCUIT SETTING
BALANCING VALVE
(DOUBLE CHECK VALVE ASSEMBLY)
OPEN SITE DRAIN
ADR
FD
CO
OS
RD
AREA DRAIN
CLEANOUT
FLOOR DRAIN
ROOF DRAIN
CBV
HB
SA
HOSE BIBB
PIPE RISING UP
PIPE DROPPING DOWN
TEMPERATURE TRANSMITTER
PRESSURE TRANSMITTER OR
PRESSURE SWITCH
UNION - SCREWED OR FLANGED
GAUGE WITH GAUGE COCK/
PRESSURE INDICATOR
BACKFLOW PREVENTOR
THERMOMETER/TEMPERATURE
PI/GA
TH/TI
PT/PS
INDICATOR
TT
FS
FLOW SWITCH
PIPING ELEMENTS/VALVING
FCO FLOOR CLEAN OUT
STACK/VENT THRU ROOF NUMBER
SHEET NOTE NUMBER
PLANS & PIPING DIAGRAMS
CONNECT NEW TO EXISTING
TERMINATION POINT OF DEMOLITION
POINT OF BEAM PENETRATION
CONNECT TO MANUFACTURER'S
PREPIPED CONNECTION
PREPURCHASED EQUIPMENT
(NUMBER)
LOCATION POINT FOR
INDICATES REVISION & NUMBER
COORDINATION BETWEEN FLOOR
X
X
SECTION APPEARS
INDICATES PIPE SIZE
INDICATES RISER DESIGNATION
INDICATES SECTION NUMBER
INDICATES ON WHICH DRAWING
X
X
X
X
EQUIPMENT IDENTITY
EQUIPMENT NUMBER
EQUIPMENT (SEE SCHEDULE)
ON DRAWINGS)
DETAIL APPEARS
INDICATES DETAIL LETTER
(APPLIES ONLY WHERE INDICATED
INDICATES DRAWING ON WHICH
X
X
X
ABBREVIATION
REFERENCE SYMBOLS
X
PIPE CAP
SERVICE SINKS/S
PHASEPH
EQUALEQ
MIN
FLEX FLEXIBLE
DEGREES FAHRENHEIT
ELECTRIC WATER COOLER
FIN
FL
FD
FA
FB
°F
-
FLOOR DRAIN
FINISHED
FLANGE
FROM BELOW
FROM ABOVE
-
EW
EXT
EWC
EQUIV
ETC
EQUIP
EYE WASH
EXTERNAL
AND SO FORTH
EQUIVALENT
EQUIPMENT
NIC
NPW
NOM
NTS
NO
No
NH
M
NC
(N)
MISC
MTD
DEGREES CENTIGRADE°C
ID
DOWNDN
ENT
ELEV
EA
(E)
-
DWG
ENTERING
ELEVATION
EACH
EXISTING
DRAWING
-
DIW
DISCH
DIAG
DIA
DF
DOWN IN WALL
DISCHARGE
DIAGRAM
DIAMETER
DRINKING FOUNTAIN
MED
MR
MFR
MC
MAX
LAV
-
LT
K
INCL
-
INV
CONTR
CS
CP
CONT'N
CONC
CONN
CONTRACTOR
CONCRETE PIPE
CUP SINK
CONCRETE
CONTINUATION
CONNECTION
COL
COMP
CO
C
CLG
CI
COMPRESSOR
COLUMN
CLEAN OUT
CAST IRON
CEILING
CENTER LINE
HR
-
HTR
HD
HB
HT
GPD
GPH
GPM
-
GA
GALV
GC
MINIMUM
ROOF OVERFLOW DRAIN
REINFORCED CONCRETE PIPE
NOT IN CONTRACT
NON-POTABLE WATER
NOMINAL
NOT TO SCALE
NUMBER
NORMALLY OPEN
NO HUB
NORMALLY CLOSED
TYPE OF COPPER TUBING
NEW
MOUNTED
MISCELLANEOUS
RISE IN WALLRIW
-
SCHEDULE
SCHEMATIC
ROOM
SHOCK ABSORBER
SCH
SCHEM
SA
ROD
-
RM
RELIEF
ROOF DRAIN
REQUIRED
RUN IN ENCLOSURE
RUN IN CASEWORK
REQD
RICW
RIE
RCP
REL
RD
WATER METER
WATER CLOSET
WATER CLOSET-HANDICAPPED
- -
WM
WCH
WC
RUN BELOW CEILING
POST INDICATOR VALVE
POLYVINYL CHLORIDE
PRESSURE INDICATOR
POLYVINYL COATED STEEL
PRESSURE TRANSMITTER
POUNDS PER SQUARE
POUNDS PER SQUARE INCH
PLUMBING CONTRACTOR
POUNDS PER SQUARE
RUN BETWEEN JOIST
INTERNAL DIAMETER
MECHANICAL CONTRACTOR
MANUFACTURER
MOP RECEPTOR
MEDIUM
MAXIMUM
LAVATORY
LEVEL TRANSMITTER
TYPE OF COPPER TUBING
-
INCLUDING
INVERT
-
RUN BELOW GRADE
RUN BELOW FLOOR
RUN AT CEILING
RUN ABOVE FLOOR
RBG
RBF
RBJ
RAF
RBC
RATC
RUN ABOVE CEILING
-
QUANTITY
-
RETURN AIR
QUICK DISCONNECTQD
RAC
RA
-
QUAN
-
PI
HEAD (SEE SCHEDULES)
-
HOUR
HEATER
HOSE BIBB
HEIGHT
GENERAL CONTRACTOR
GALLONS PER MINUTE
GALLONS PER HOUR
GALLONS PER DAY
-
GALVANIZED
GAUGE
INCH GAUGE
PLUG VALVE
INCH ABSOLUTE
PV
PVS
PVC
PC
PSIA
PT
POSITIVE
PRESSURE
PRESSURE SWITCH
PSIG
PSI
PS
POS
PRESS
PIV
TEMPERATURE
TYPICAL
TEMPERATURE TRANSMITTER
TOTAL PRESSURE
TEMPERATURE INDICATOR
WITHOUT
VENT THRU ROOF
VIBRATION ISOLATOR
W/
W/O
W
WITH
WIDTH
-
VTR
VI
UR
-
URINAL
TI
TYP
TT
TP
TEMP
SAFETY SHOWER
SQUARE
SPECIFICATION
STANDARD
SYSTEM
SUPPLY
STRUCTURAL
TOTAL DYNAMIC HEAD
SUPPORT STEEL
STAINLESS STEEL
STEAM IN PLACESIP
-
TDH
S/SHO
-
SYS
SUP
STR
STD
STL
SST
STEEL
SQ
SS
SPEC
BACK FLOW PREVENTOR
ABOVE FINISHED FLOOR
CUBIC FEET PER MINUTE
CUBIC FEET PER HOUR
CONCRETE HOUSEKEEPING PAD
BUILDINGBLDG
CFM
CHP
CFH
BSMT
-
BLW
BASEMENT
BELOW
-
BFP
-
AP
ABV
AFF
ACCESS PANEL
-
ABOVE
FS
FPH
-
FXC
FTB
FT
FTC
FP
FPS
FPM
FLR
FLOW SWITCH
FLOOR TO BOTTOM
FLEXIBLE CONNECTION
FROST PROOF HYDRANT
FLOOR TO CENTERLINE
-
FEET
FEET PER SECOND
FEET PER MINUTE
FIRE PROTECTION
FLOOR
-
OUNCE
PERFORATED
PLENUM DRAIN
PLUMBING FIXTURE
IDENTIFICATION
PARTIAL
PERF
P-
PDR
PART
-
OZ
OVERFLOW
OUTSIDE DIMENSION
OFF TOP
OPEN SITE
OF
OS
OT
OD
PLUMBING ABBREVIATIONS
FSK FLOOR SINK
PUMP
PIPE CONTINUE
BALANCING VALVE
CWP
LEAVING AIR TEMPERATURELAT
UNIT HEATER
WET BULB
UNLESS OTHERWISE NOTED
VARIABLE AIR VOLUME UNIT
WIRE MESH SCREEN
VENT THRU ROOF
VOLUME DAMPER
EXPANSION JOINT
DUCT SILENCER
EXHAUST FAN
DRY BULB
EXHAUST REGISTER
ENTERING AIR TEMPERATURE
ELECTRICAL CONTRACTOR
DOMESTIC WATER PUMP
ER
EAT
EJ
EF
EC
DS
DWP
DB
LEAVING WATER TEMPERATURE
MOTOR OPERATED DAMPER
MECHANICAL CONTRACTOR
MUA
LINEAR DIFFUSER
MOUNTED
LINEAR FEET
MAKE-UP AIR UNIT
MOD
MTD
MC
LF
LD
LWT
VD
WB
WMS
VTR
VAV
UON
UH
NECK
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
OUTSIDE AIR INTAKE
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
ON CENTER
OPPOSED BLADE DAMPER
PARALLEL BLADE DAMPER
PRESSURE REDUCING VALVE
OUTSIDE DIAMETER
PACKAGED TERMINAL AIR CONDITIONER
REHEAT COIL
RETURN FAN
SUPPLY AIR
REFLECTED CEILING PLAN
RETURN AIR GRILLE
RETURN AIR REGISTER
SUPPLY AIR REGISTER
TYPICAL
SUPPLY FAN
SMOKE EXHAUST FAN
SMOKE CONTROL GRILLE
STATIC PRESSURE
TRANSFER GRILLE
SMOKE DAMPER
RETURN AIR
CONDENSATE PUMP
CEILING DIFFUSER
CLEAN OUT
CHILLER
CONDENSING UNIT
COOLING TOWER
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSER WATER PUMP
CONSTANT VOLUME BOX
CABINET UNIT HEATER
CUBIC FEET PER MINUTE
CHILLED WATER PUMP
CVB
CUH
CU
CWS
CT
CWR
CHWP
CHWS
CO
CP
CHWR
CD
CFM
C
ACOUSTICAL LINING
AIR HANDLING UNIT
ACCESS DOOR
BOTTOM OF BEAM
BACK DRAFT DAMPER
BOTTOM OF PIPE
BOTTOM OF DUCT
ACCESS PANEL
AIR HANDLER (SPLIT REFRIG)
BELOW FINISHED CEILING
ELECTRIC BASEBOARD RADIATION
ABOVE FINISHED FLOOR
AIR CONDITIONING UNIT
AP
BOP
BOD
BOB
BFC
B
BDD
BB
BOILER
AL
AHU
AH
AFF
AD
AC
RA
FINNED TUBE RADIATION
HEATING AND VENTILATING UNIT
HEATING HOT WATER RETURN
HEATING HOT WATER SUPPLY
HEAT EXCHANGER
INSIDE DIAMETER
HOT WATER PUMP
HOT WATER CONVERTER
HZ
ID
HX
HERTZ
HWR
HWS
HWP
HWC
HAND DAMPER
HEAT PUMP
GENERAL CONTRACTOR
GALLONS PER HOUR
GALLONS PER MINUTEGPM
HP
HV
HD
GPH
GC
FTR
SAR
SF
TYP
TG
SP
SD
SEF
SCG
SA
RHC
RF
RAR
RCP
RAG
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
ELECTRIC WATER COOLER
FAN COIL UNITFC
FIRE DAMPER
FLAT ON TOP
FLAT ON BOTTOM
FUEL OIL PUMP
FIRE PUMP
FEET PER MINUTEFPM
FP
FOP
FOT
FOB
FLR
FD
FLOOR
EXPANSION TANK
FREE AREA
FLEXIBLE CONNECTION
FA
FX
EWC
EWT
ET
ESP
PRV
PTAC
PBD
OBD
OD
OC
OAI
OAT
NK
OA
NO
NIC
NC
HVAC ABBREVIATIONS
OXYGENO2
NATURAL GAS
NITROUS OXIDEN20
AIR (DENTAL)AIR
VACUUM (DENTAL)VAC
COLD WATER (DENTAL)DEN CW
METER, INLINEM
X
CONTROL SYMBOLS
DESCRIPTION
DISCONNECT SWITCH
CONTROL TRANSFORMER
CLOSED CONTACTS
THERMAL OVERLOAD
HAND-OFF-AUTO
SELECTOR SWITCH
WIRING CONNECTION
ON-OFF SELECTOR SWITCH
ROOM TEMPERATURE SENSOR
WIRING DESIGNATION. (NO. OF HATCHES
STRAP-ON TEMPERATURE SENSOR
INDICATES NO. OF CONDUCTORS)
NORMALLY OPEN AND NORMALLY
ROOM HUMIDITY SENSOR
FIBER OPTIC INTERFACE
ROOM AIR QUALITY SENSOR
PNEUMATIC RESTRICTOR
AIR FLOW MONITORING STATION
PILOT LIGHT (WITH LENS COLOR)
ROOM TEMPERATURE SENSOR
WITH SETPOINT ADJUST AND
OVERRIDE
ROOM TEMPERATURE SENSOR
WITH GUARD
NEW DIGITAL CONTROL STATION
DUCT AIR QUALITY SENSOR
PNEUMATIC TO CURRENT
PNEUMATIC HIGH / LOW
SIGNAL SELECTOR
IP#
O
MI
LS# LIMIT SWITCH
TRANSDUCER
WATER FLOW SWITCH
MAIN AIR SUPPLY
CURRENT SENSOR
DAMPER ACTUATOR
FOI
R
H
DCS
A
DIFFERENTIAL PRESSURE
ELECTRIC-PNEUMATIC RELAY
PNEUMATIC-ELECTRIC SWITCH
CURRENT TO PNEUMATIC
THREE WAY CONTROL VALVE
TWO WAY CONTROL VALVE
SP#SP=
NO
C
P
NC
PE#
IP#
O
MI
M
TRANSDUCER
I
NO
NC
C
EP#
SMOKE DETECTOR
ON-OFF
DDC POINT DESCRIPTOR
TEMPERATURE SENSOR WITH
LOW TEMPERATURE SWITCH
HIGH TEMPERATURE SWITCH
WITH AVERAGING ELEMENT
(FIRESTAT)
(FREEZESTAT)
TEMPERATURE SENSOR
WITH PIPE WELL
HUMIDITY SENSOR
SYMBOL
TEMPERATURE SENSOR
SINGLE POINT ELEMENT
DESCRIPTION
WITH NAME
AI - ANALOG INPUT
AO - ANALOG OUTPUT
DO - DIGITAL OUTPUT
DI - DIGITAL INPUT
AUTO
OFF
HAND
OL
FUSE
VOLTAGE2
VOLTAGE1
SYMBOL
RELAY COILS
WD
WATER DETECTOR
ZN 1 DAMPERNAME AI
AODESCRIPTION NAME
TT
-#
TT
-#
TT-#
HT
-#
FZ
-#
FS
-#
SD-#
DP-#
V#
V#
D#
M
FS
-#
CO
2
T
SG
T
SO
T
TT-#
R # EP #
R #-# R #-#
CONTROL SYMBOLS
R
O
B
E
R
T
T
S
A
W
Y
E
R
R
E
G
I
ST
E
R
E
D
P
R
O
F
E
S
S
I
O
NAL
E
N
G
I
N
E
E
R
13224
S
T
A
T
E
OF
I
D
A
H
O
DRAWING INDEX
SCALE: NONE
P0.0
1
BRINE
TANK #1
BRINE
TANK #4
BRINE
TANK #5
M TRUCK CONNECTION
NC
NO C
1
P
1
F
2
V
4
V
6
V
9
V
10
V
1
V
3
V
5
V
8
V
7
V
BOOST
TANK #6
M TRUCK CONNECTION
NC
NO C
2
P
2
F
12
V
15
V
16
V
11
V
14
V
13
V
MAG
TANK #2
M TRUCK CONNECTION
NC
NO C
3
P
3
F
18
V
20
V
23
V
24
V
17
V
19
V
22
V
MAG
TANK #3
21
V
R
O
B
E
R
T
T
S
A
W
Y
E
R
R
E
G
I
ST
E
R
E
D
P
R
O
F
E
S
S
I
O
NAL
E
N
G
I
N
E
E
R
13224
S
T
A
T
E
OF
I
D
A
H
O
SHEET NOTES
1 STORAGE TANKS ARE SUPPLIED BY THE GENERAL CONTRACTOR
AND INSTALLED BY THE MECHANICAL CONTRACTOR
BRINE SYSTEM SCHEMATIC
SCALE: NONE
P3.0
1
2 LABEL VALVES WITH VALVE TAG NUMBER AND LABEL EACH PORT AS
NORMALLY OPEN (NO) NORMALLY CLOSED (NC) OR COMMON (C).
POST A LAMINATED COPY OF THE VALVE OPERATION SCHEDULE
NEARBY EACH VALVE
PUMP SCHEDULE
SCALE: NONE
P3.0
4
MAG SYSTEM SCHEMATIC
SCALE: NONE
P3.0
3
3
BOOST SYSTEM SCHEMATIC
SCALE: NONE
P3.0
2
FIXTURE SCHEDULE
SCALE: NONE
P3.0
5
1
111
1 1
2 2
2
1
T
2
T
3
T
4
T
5
T
6
T
M
1
P
M
2
P
M
3
P
3
F
3" BRINE
3" BOOST
3" MAG
2" DRAIN
3" BOOST
3" BRINE
2
F
1
F
2
V
1
V
4
V
3
V
5
V
6
V
11
V
12
V
7
V
8
V
9
V
10
V
14
V
13
V
15
V
16
V
18
V
17
V
19
V
20
V
21
V
22
V
24
V
23
V
FIRST FLOOR, PLUMBING
SCALE: 3/16" = 1'
N
0 2 4 8
1
P4.1
SHEET NOTES
R
O
B
E
R
T
T
S
A
W
Y
E
R
R
E
G
I
ST
E
R
E
D
P
R
O
F
E
S
S
I
O
NAL
E
N
G
I
N
E
E
R
13224
S
T
A
T
E
OF
I
D
A
H
O
1
2
3
4
BRINE, BOOST AND MAG CHLORIDE PIPING SHALL BE SCH 80 PVC
WITH FLEXIBLE CONNECTIONS TO TANKS AND PUMPS, PAINT ALL
PIPING EXPOSED TO SUNLIGHT ACCORDING TO SPECIFICATION
SECTION 099000
ALL PIPING SHALL BE HUNG WITH NON-FERROUS STRUTS, BRACKETS
AND HARDWARE (AICKINSTRUT FIBERGLASS OR EQUAL)
TERMINATE BRINE AND BOOST TRUCK LOAD AND UNLOAD
CONNECTIONS WITH 3" FEMALE CAMLOCK FITTING
2
TERMINATE MAG CHLORIDE TRUCK LOAD AND UNLOAD
CONNECTIONS WITH 3" MALE CAMLOCK FITTING
4
1
21
5 MANUAL RAIN WATER DRAIN THROUGH SECONDARY CONTAINMENT
WALL
5
3
3
3" FULL PORT VALVE,
BANJO 6 BOLT V300FP
OR EQUAL
FLEXIBLE HOSE
WITHIN 6' OF TANK
CONNECTION
RECIRC LINE, TERMINATE INSIDE TANK
WITH 3" 90 DEGREE ELBOW, CLOCKED
AT 45 DEGREES AND MITER CUT
BRINE / BOOST
TERMINATION: 3"
FEMALE CAMLOCK
MAG TERMINATION: 3"
MALE CAMLOCK WITH CAP
PUMP BEDPLATE + 6"
LEVEL GROUT
PUMP BEDPLATE
PUMP
MOTOR
PUMP DISCHARGE SIZE
FLANGED INCREASER
GAGE
GAGE
SUCTION
PIPE SIZE SHALL BE
AS SHOWN ON PLAN
FLOOR LINE
GROUT
STUFF WASTE
AROUND BOLT
WHILE POURING
GROUT
LEAVE SURFACE
OF FOUNDATION
ROUGH TO AFFORD
GOOD HOLD FOR
GROUT
PIPE OR CONDUIT
3 TIMES DIAMETER
OF BOLT. DO NOT
EXTEND ABOVE
ROUGH SURFACE
OF FOUNDATION
ARRANGEMENT OF
FOUNDATION BOLT
HOLD DOWN BOLTS
DISCHARGE
TANK WALL
RE-CIRCULATION
LINE, FLEXIBLE
HOSE
RE-CIRCULATION
LINE, SHUTOFF
VALVE
TERMINATE
INTERIOR PIPING
WITHIN 2" OF TANK
FLOOR
POURED CONCRETE
PIPE (TO PUMPS)
MASTIC COATING
ON WALL & PIPE
PACKED OAKUM
LINK SEAL
ESCUTCHEON
PLATE
WATER STOP & ANCHOR COLLAR
CONTINUOUSLY WELDED ALL AROUND
PIPE SLEEVE
TO SLEEVE. MIN. 1"
CONTAINMENT WALL
PIPE (TO TANKS)
SCALE: NONE
P5.0
1
SCALE: NONE
P5.0
2
SCALE: NONE
P5.0
3TRUCK LOAD / UNLOAD, BRINE - BOOST
SCALE: NONE
P5.0
4
TANK CONNECTION
SCALE: NONE
P5.0
5
TRUCK LOAD / UNLOAD, MAG
BASE MOUNTED PUMP
R
O
B
E
R
T
T
S
A
W
Y
E
R
R
E
G
I
ST
E
R
E
D
P
R
O
F
E
S
S
I
O
NAL
E
N
G
I
N
E
E
R
13224
S
T
A
T
E
OF
I
D
A
H
O
INTERIOR TANK TERMINATION
SCALE: NONE
P5.0
6 PIPE THROUGH CONTAINMENT WALL