ammonia unloading storage

2
Industries Benefits Single Source Accountability Pre-Packaged Modular Design Costs Less Than Component Based Site-Built Systems Reducing Overall Project Cost Minimizes Field Erection Time - Shorter Overall Project Delivery Schedule Complete System Function Testing Prior To Shipment 24/7 Customer Service Industry Standards Vessels Code Stamped ASME Section VIII & National Board Registered Piping Designed to ANSI B31.1/ANSI B31.3 Pipe Fabrication to ASME Section IX Structural Steel Assembly Designed to AWS D1.1 Complete System Designed to API RP 550 & K61.1 INTEGRATED FLOW SOLUTIONS 9800 Northwest Freeway, Suite 205 Houston, Texas 77092 713-956-9473 ANAM-100.0 Integrated Flow Solutions Anhydrous Ammonia Unloading Stations & Storage/Forwarding Systems are designed to unload Anhydrous Ammonia from transports into a modular Storage/Vaporizer System which includes a storage tank, vaporizer, instrumentation and controls. The complete system is designed to minimize field assembly. The vaporizing system is designed to transfer the Anhydrous Ammonia to the Ammonia Flow Control Unit (AFCU). Anhydrous Ammonia Unloading Station & Storage/Vaporizer System Standard Features INTEGRASAFE TM Unloading Station Local Indication of: Tank Level Tank Pressure Flow Indication Local Manual/Automated Valve Operation Storage/Forwarding System Vessel Storage Up to 30,000 Gallons Single & Double Wall Carbon Steel Vessels INTEGRAHEAT TM Electrical Vaporizer ASME Code Stamped (Locally Mounted) Full Thyrister (SCR) Control Panel with Redundant Safety Shutdown System (Locally Mounted) per NEC & NFPA Complete Factory Function Test Optional Features UL or CSA Listed Heater and Control Panel Assembly per NEC & NFPA Class 1, Div. 2 Hazardous Locations Compliance with Plant/Engineering Specifications Additional Services “Aspen Plus” Process Simulation Software Used To Guarantee Process Conditions Installation/Training/Start-Up Supervision Extended Warranty Nationwide Service Network EMISSIONS GENERAL POWER www.IFSolutions.com www.IFSolutions.com

Upload: mohamed-ghadhab

Post on 23-Oct-2015

82 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Ammonia Unloading Storage

Industries

Benefits Single Source Accountability Pre-Packaged Modular Design Costs Less

Than Component Based Site-Built Systems Reducing Overall Project Cost

Minimizes Field Erection Time -Shorter Overall Project Delivery Schedule

Complete System Function TestingPrior To Shipment

24/7 Customer Service

Industry Standards Vessels Code Stamped ASME Section VIII &

National Board Registered Piping Designed to ANSI B31.1/ANSI B31.3 Pipe Fabrication to ASME Section IX Structural Steel Assembly Designed to AWS D1.1 Complete System Designed to API RP 550 & K61.1

INTEGRATED FLOW SOLUTIONS 9800 Northwest Freeway, Suite 205 Houston, Texas 77092 713-956-9473

ANAM-100.0

Integrated Flow Solutions Anhydrous AmmoniaUnloading Stations & Storage/Forwarding Systemsare designed to unload Anhydrous Ammonia fromtransports into a modular Storage/Vaporizer Systemwhich includes a storage tank, vaporizer,instrumentation and controls. The complete system isdesigned to minimize field assembly. The vaporizingsystem is designed to transfer the Anhydrous Ammoniato the Ammonia Flow Control Unit (AFCU).

Anhydrous AmmoniaUnloading Station &Storage/Vaporizer System

Standard Features INTEGRASAFETM Unloading Station

Local Indication of:Tank LevelTank PressureFlow Indication

Local Manual/Automated Valve Operation Storage/Forwarding System

Vessel Storage Up to 30,000 Gallons Single & Double Wall Carbon Steel Vessels INTEGRAHEATTM Electrical Vaporizer ASME

Code Stamped (Locally Mounted) Full Thyrister (SCR) Control Panel with

Redundant Safety Shutdown System (LocallyMounted) per NEC & NFPA

Complete Factory Function Test

Optional Features UL or CSA Listed Heater and Control Panel

Assembly per NEC & NFPA Class 1, Div. 2 Hazardous Locations Compliance with Plant/Engineering Specifications

Additional Services “Aspen Plus” Process Simulation Software Used

To Guarantee Process Conditions Installation/Training/Start-Up Supervision Extended Warranty Nationwide Service Network

EMISSIONSGENERALPOWER

www.IFSolutions.com

www.IFSolutions.com

Page 2: Ammonia Unloading Storage

Anhydrous Ammonia UnloadingStation & Storage Vaporizer System

INTEGRATED FLOW SOLUTIONS 9800 Northwest Freeway, Suite 205 Houston, Texas 77092 713-956-9473LIT ANAM-100.0 10022004 IFS These materials contain proprietary information and may not be reproduced without prior written permission from Integrated Flow Solutions.

WORKING VOLUME -GALLONS LENGTH - X WIDTH - Y HEIGHT - Z WEIGHT - LBS.

6,000 20’ 11’ 14’ 15,00010,000 34’ 11’ 14’ 25,00014,000 50’ 11’ 14’ 35,00018,000 60’ 11’ 14’ 45,00022,000 75’ 12’ 16’ 55,000

ATMOS.

ATMOS.

ATMOS.

DRAIN

ATMOS.

NC

ANHYDROUS AMMONIA TANK

VAPORIZER ASSY.ELECTRIC HEATER

24" MANWAY

ATMOS.

ATMOS.

S

FC

ATMOS.

SCR PANEL

SKID LIMITS

I

AT

I

AMMONIATRANS.

PERPENDICULAR TO WORLD COORDINATES.ALL NOZZLES SHALL BE ORIENTEDNOTE:

ELECTRIC HEATERVAPORIZER ASSY.

VENT

LO

ADIN

G S

KID

ANHY

DROU

S AM

MON

IA IN

LET

OUT

LET

TO P

ROCE

SS

BY CUSTOMER1/2" INSTRUMENT AIR

SKID LIMITS

2"x3"

1"

1"

2"x1"

1"1"x

1/2"

2"

2"

2"x1

" 2" 2"

ATMOS.

2"x1"

2"

2"2"

1 1/2"

2"x1

1/2

"

2"x1

1/2

"

2"

E L E V A T I O N V I E W

L VESSELC

VAPORIZER-02 (FAR SIDE)VAPORIZER-01 (NEAR SIDE)

8070

60

10090

5040

3020

100

010

2030

40 50

90100

60

7080

01020

304050

90100

6070

80

"X" OVERALL SKID LENGTH

"Z" A

PP

RO

X. O

VE

RA

LL H

EIG

HT

P L A N V I E W VAPORIZER-01

VAPORIZER-02

"X" OVERALL SKID LENGTH

"Y" O

VE

RA

LL S

KID

WID

TH

www.IFSolutions.com