alumbrado de emeregencia - wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma...
TRANSCRIPT
![Page 1: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/1.jpg)
1
ALUMBRADO DE EMERGENCIA
![Page 2: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/2.jpg)
2
CLASIFICACION
ALUMBRADO
NATURAL
ARTIFICIAL
NORMAL
EMERGENCIA
ESCAPE
RESERVA
ESCAPE DE AMBIENTE
VER NORMA IRAM AADLJ2027 (AGOSTO 1990)
SEGURIDAD
![Page 3: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/3.jpg)
3
ALUMBRADO DE RESERVAES EL DESTINADO A SEGUIR CON LAS TAREAS QUE NO IMPLIQUEN RIESGO PARA EL OPERARIO.PROVISTO EN GENERAL POR GRUPOS ELECTROGENOSSI SE ACCIONA, SE DEBERA ENCENDER AUTOMATICAMENTE EL ALUMBRADO DE ESCAPE.EL ALUMBRADO DE RESERVA NO ES DE USO OBLIGATORIO
ALUMBRADO DE EMERGENCIASE PONE EN FUNCIONAMIENTO CUANDO FALLA EL
ALUMBRADO NORMAL
![Page 4: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/4.jpg)
4
ALUMBRADO DE ESCAPE
EVACUAR PERSONAS RAPIDA Y SEGURAMENTE ATRAVES DE LOS MEDIOS DE ESCAPEFACILITAR LAS MANIOBRAS DE SEGURIDAD E INTERVENCIONES DE AUXILIOPERMANECER ENCENDIDO NO MENOS DE 1,5 HS PROVEYENDO LAS ILUMINANCIAS EXIGIDAS EN CADA CASOINDICAR CLARAMENTE LOS MEDIOS DE ESCAPESEÑALIZAR E ILUMINAR LOS PUNTOS DE ALARMA Y EQUIPOS PARA COMBATIR INCENDIOSPROVEER ALUMBRADO DE ESCAPE AMBIENTEEL ALUMBRADO DE ESCAPE ES DE USO OBLIGATORIO
PARTE DEL ALUMBRADO DE EMERGENCIA DESTINADO A:
![Page 5: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/5.jpg)
5
ALUMBRADO DE ESCAPE DE AMBIENTE
PARTE DEL ALUMBRADO DE ESCAPE DESTINADO A
ORIENTAR A LAS PERSONAS RAPIDA Y SEGURAMENTE
HACIA LOS MEDIOS DE ESCAPE
ES DE USO OBLIGATORIO
![Page 6: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/6.jpg)
6
ALUMBRADO DE SEGURIDAD
PARTE DEL ALUMBRADO DE EMERGENCIA DESTINADO A CONTINUAR CON TAREAS EN PUESTOS DE TRABAJO CON RIESGO POTENCIAL.EJEMPLOS:
QUIROFANOSSALAS DE TERAPIA INTENSIVASIERRAS CIRCULARESTORRES DE CONTROL DE AEROPUERTO
ES DE USO OBLIGATORIO
![Page 7: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/7.jpg)
7
ILUMINANCIAS EN RUTAS DE ESCAPE (911)
PLANO DE MEDICION DE ILUMINANCIAS: SOLADO
MINIMA EN EL CENTRO DE LA CIRCULACION: 5 lx
MAYOR QUE EL 5% DE LA ILUMINANCIA GENERAL
UNIFORMIDAD: Emax/Emin = 40:1
![Page 8: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/8.jpg)
8
ILUMINANCIAS EN RUTAS DE ESCAPE (911)
VALORES PROPIOS PARA CADA LUMINARIA
![Page 9: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/9.jpg)
9
LUMINANCIAS MAXIMAS EN RUTAS DE ESCAPE (911)
LAS LUMINARIAS NO DEBERAN PRODUCIR DESLUMBRAMIENTO(IRAM AADL J2027 8/90)
2 m
4 m
5 m
Imax = 100 cd
Imax = 2500 cd
Imax = 5000 cd
Imax = 900 cd3 m2,5 m Imax = 400 cd
3,5 m Imax = 1600 cd
4,5 m Imax = 3500 cd
0 m
![Page 10: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/10.jpg)
10
POSICIONES A DESTACARLOCALES DE USO TEMPORARIO QUE NO RECIBAN LUZ
NATURAL O DE USO NOCTURNOCORREDORES, ESCALERAS, RAMPASTUNELES, EXCAVACIONESRUTAS DE ESCAPE, SALIDAS Y SALIDAS DEEMERGENCIA (PERMANENTE)CAMBIOS DE NIVEL DE PISO ESCALERAS Y CORREDORESINTERSECCIONES DE PASILLOSASCENSORES, MONTACARGAS, BAÑOS, VESTUARIOSSALAS DE MAQUINAS DE PROVISION DE ENERGÍASALAS DE SERVICIOS ESCENCIALESEQUIPOS Y SISTEMAS PARA INCENDIO (PERMANENTE)
![Page 11: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/11.jpg)
11
FUNCIONAMIENTO BASICO LA NECESIDAD ES:TENSION
NORMAL ?
CARGA
BATERIA
TENSIONNORMAL
? BATERIA
CARGADOR
![Page 12: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/12.jpg)
12
FUNCIONAMIENTO CON LAMPARA FLUORESCENTE
MAS EFICIENCIA
TENSIONNORMAL
MAS VIDA DE LAMPARAMAS AUTONOMIA
? BATERIA
CARGADORBALASTO ELECTRONICO
?
![Page 13: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/13.jpg)
13
LINEA NOINTERRUMPIBLE
kWh TABLERO
CIRCUITODE TOMAS
CIRCUITO DEILUMINACION
LINEA NOINTERRUMPIBLE
![Page 14: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/14.jpg)
14
SISTEMAS DE ALUMBRADO DE ESCAPE Y SEGURIDAD
AUTONOMOS
PERMANENTES
NO PERMANENTES
NO AUTONOMOS
PERMANENTES
NO PERMANENTES
bateríaincorporada
bateríacentral
![Page 15: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/15.jpg)
15
PERMANENTES Y NO PERMANENTES
¿LAMPARA QUEMADA?
![Page 16: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/16.jpg)
16
EQUIPO AUTONOMO
![Page 17: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/17.jpg)
17
AUTONOMOS FLUORESCENTES
FACTOR DE FLUJO: RELACION ENTRE FLUJO LUMINOSOEMITIDO EN EMEREGENCIA Y CON ALIMENTACIÓN NORMALVALORES HABITUALES: 0.08 ~ 0.20
![Page 18: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/18.jpg)
18
LUMINARIAS INCANDESCENTES
![Page 19: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/19.jpg)
19
LUMINARIAS INCANDESCENTES
![Page 20: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/20.jpg)
20
AUTONOMOS INCANDESCENTES
FACTOR DE FLUJO: HABITUAL 1AUTONOMIA MINIMA: 1,5 HS CON 50 W
![Page 21: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/21.jpg)
21
AUTONOMOS INCANDESCENTES
FACTOR DE FLUJO: HABITUAL 1AUTONOMIA MINIMA: 1,5 HS CON 50 W
![Page 22: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/22.jpg)
22
CENTRALES
![Page 23: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/23.jpg)
23
LUMINARIAS PARA CENTRALES
![Page 24: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/24.jpg)
24
CONEXIONADO DE CENTRALES
![Page 25: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/25.jpg)
25
BATERIAS ACEPTABLES
• ESTACIONARIAS: PLOMO ACIDO O NIQUEL-CADMIO• PERIODO DE RECARGA: MAXIMO 24 HS• SIN MANTENIMIENTO EN EQUIPOS AUTONOMOS• PROHIBIDOS LAS DE PLOMO ACIDO DE USO EN AUTOMOTORES
![Page 26: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/26.jpg)
26
SEÑALIZACION
h
l h = lZ
• l = DISTANCIA DE VISIBILIDAD• Z = 100 PARA SEÑALES ILUMINADAS POR REFLEXION• Z = 200 PARA SEÑALES TRASILUMINADAS• ALTURA DE MONTAJE 2 m a 2,50 M• SEÑALES: NORMA IRAM 10005
![Page 27: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/27.jpg)
27
PICTOGRAMAS
![Page 28: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/28.jpg)
28
FORMAS DE INSTALACION
BANDERA
SUSPENDIDO
PARED
![Page 29: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/29.jpg)
29
INDICADORES FLUORESCENTES
![Page 30: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/30.jpg)
30
LUMINARIAS FLUORESCENTES
![Page 31: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/31.jpg)
31
INDICADORES CON LEDs
![Page 32: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/32.jpg)
32
INDICADORES CON LEDs
![Page 33: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/33.jpg)
33
LUMINARIAS PORTATILES
• SOLO PARA OBRAS SIN PELIGRO DE EXPLOSION
• SOLO PARA LOCALES CON SALIDA AL EXTERIOR SIN ESCALERAS, PASILLOS O CORREDORES
• RECORRIDO MAXIMO: 30 M
![Page 34: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/34.jpg)
34
EJEMPLOS
SALIDA DE EMERGENCIA
![Page 35: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/35.jpg)
35
EJEMPLOS
BOTIQUIN DE PRIMEROSAUXILIOS
![Page 36: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/36.jpg)
36
EJEMPLOS
MATAFUEGOS
![Page 37: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/37.jpg)
37
EJEMPLOS
RAMIFIACION DE CORREDORES
![Page 38: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/38.jpg)
38
EJEMPLOS
ALARMAS DE INCENDIO
![Page 39: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/39.jpg)
39
EJEMPLOSCAMBIO DE NIVELEN PAVIMENTO
![Page 40: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/40.jpg)
40
EJEMPLOS
SENALIZADOR DE SALIDA
SALIDA
![Page 41: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/41.jpg)
41
EJEMPLOS
ESCALERA
![Page 42: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/42.jpg)
42
EJEMPLOS
SALIDA
![Page 43: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/43.jpg)
43
EJEMPLOS
CAMBIO DE DIRECCION
![Page 44: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/44.jpg)
44
EJEMPLO DE INDUSTRIARESERVASEGURIDAD
SEÑALIZACION
![Page 45: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/45.jpg)
45
SALA DE DIBUJO
![Page 46: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/46.jpg)
46
AULA
![Page 47: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/47.jpg)
47
VIAS DE ESCAPE
![Page 48: Alumbrado de Emeregencia - Wamcowamco.com.ar/wp-content/uploads/2014/12/clase_al... · ver norma iram aadl ... (iram aadl j2027 8/90) 2 m 4 m 5 m imax = 100 cd ... • seÑales: norma](https://reader030.vdocuments.site/reader030/viewer/2022012907/5b499bc27f8b9a93238b8a1f/html5/thumbnails/48.jpg)
48
VESTUARIO