Version 1.4 – December 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com
ALLIANCE Multi-Operator DAS 5W Mid-Power Remote Unit (MROU) Product Specification
• Guaranteed RF Power Control
• Support for 12 Individual Bands on a Single Fiber. 4G Certified, MIMO Capable
• NFPA72 Compliant / NEMA4 / UL Labeled
• One System Delivers 150MHz to 3GHz
• VHF/UHF Supported in Add-On Remote (AOR)
• Quality Checked and Fully Bench Tested
• Easy Install, Commissioning and Management
• Wall or Pole Mounting
• Convection Cooling – No Mechanical Fans
5 Watt Specifications Parts List
A multi-operator DAS solution that supports public safety, 2-way radio and commercial wireless services all delivered over a single fiber.
Modular design means lower operational costs and unparalleled RF performance, cost efficiency and flexibility.
Rugged construction meets the latest fire codes and requirements for harsh environmental conditions.
![Page 2: ALLIANCE Multi-Operator DAS - Hutton Communications 5W.pdf · ALLIANCE Multi-Operator DAS 5W Mid-Power Remote Unit (MROU) Product Specification!!!!! ... ALLIANCE DAS – 5W Remote](https://reader034.vdocuments.site/reader034/viewer/2022042502/5b04251f7f8b9aba168cdbe1/html5/thumbnails/2.jpg)
ALLIANCE DAS – 5W Remote Optic Unit (MROU) Product Specification
Version 1.4 – December 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com
Specifications Supported Services
Supported Services 700LTE Full Band 700PS 800 PS /
800 Sprint 850
Cellular 900 Paging 1900 PCS
2100 AWS
VHF UHF
(Requires AOR)
Frequency Range
Tx (MHz) 728-756 758-776 851-860 / 862-869 869-894 929-940 1930-1995 2110-2155 136-174 385-512
Rx (MHz) 698-716 777-787 788-806 806-815 /
817-824 824-849 896-902 1850-1915 1710-1755 136-174 385-512
RF Parameters
Input Power Tx (dBm) -20 to +10 -20 to +10 -20 to +10 -20 to +10 -20 to +10 -20 to +10 -20 to +10 -15 to +10 -15 to +10
Rx (dBm) ≤ -50 ≤ -50 ≤ -50 ≤ -50 ≤ -50 ≤ -50 ≤ -50 ≤ -54 ≤ -54
Output Power
Tx (dBm) 37 37 37 37 37 37 37 24 24
Rx (dBm) 0 0 0 0 0 0 0 -4 -4
System Gain
Tx (dBm) 57 57 57 57 57 57 57 39 39
Rx (dBm) 50 50 50 50 50 50 50 50 50
System Delay
Tx < 8µs < 8µs < 8µs < 8µs < 8µs < 8µs < 8µs < 2µs < 2µs
Rx < 8µs < 8µs < 8µs < 8µs < 8µs < 8µs < 8µs < 2µs < 2µs
Spurious Emissions Tx ≤ -13dBm @ 9kHz – 5GHz
Out of Band Attenuation Rx ≤ 45dB @ F_edge ± 1MHz offset
Gain Control Range/Step
Tx 25dB/step 1dB
Rx 20dB/step 1dB
Optical
Optic Wavelength
Tx 1550nm WDM
Rx 1310nm WDM
Optic Link AGC Above 10dB
Optic Link Loss Max 10dBo
Noise Figure 8dB Max 7dB Max
Optical Connector SC-APC (Single Mode Fiber)
RF Connector DIN-F (Common Output), N-F (UHF/VHF and AOR)
Monitoring Port -30dB (SMA Female)
![Page 3: ALLIANCE Multi-Operator DAS - Hutton Communications 5W.pdf · ALLIANCE Multi-Operator DAS 5W Mid-Power Remote Unit (MROU) Product Specification!!!!! ... ALLIANCE DAS – 5W Remote](https://reader034.vdocuments.site/reader034/viewer/2022042502/5b04251f7f8b9aba168cdbe1/html5/thumbnails/3.jpg)
ALLIANCE DAS – 5W Remote Optic Unit (MROU) Product Specification
Version 1.4 – December 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com
![Page 4: ALLIANCE Multi-Operator DAS - Hutton Communications 5W.pdf · ALLIANCE Multi-Operator DAS 5W Mid-Power Remote Unit (MROU) Product Specification!!!!! ... ALLIANCE DAS – 5W Remote](https://reader034.vdocuments.site/reader034/viewer/2022042502/5b04251f7f8b9aba168cdbe1/html5/thumbnails/4.jpg)
ALLIANCE DAS – 5W Remote Optic Unit (MROU) Product Specification
Version 1.4 – December 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com
Electrical / Environmental Parameter BIU ODU OEU MROU AOR
DC Power Normal: -48 VDC Operating range: -42 to -56V DC
- - Normal: -48 VDC Operating range: -42 to -56 VDC
AC Power - - - Normal Range: 120VAC 50/60Hz Operating Range: 108~132 VAC, 50/60Hz
Power Consumption
168W (Incl. 4 ODUs) 27W 48W (Incl. 2
DOUs) 390W (Incl. 6 RDUs) 78W (Incl. VHF/UHF RDU)
Operating Temp 14 to 122°F, -10 to +50°C 13 to 131°F, -25 to +55°C
Operating Humidity - 0% to 90% (Non-condensing)
Mechanical Product Description Size (Inches) W x H x D Weight (lbs) Power Consumption
BIU Chassis (VHF/UHF Inputs Standard) 19 x 8.72 (5U) x 17.7 49.2 88W 700MHz LTE Full Band SISO MDBU
1.57 x 5.5 x 10.96
6.82 12W 700MHz LTE Full Band MIMO MDBU 7.04 19W 800MHz & 900MHz MDBU 6.82 20W 850MHz & 700MHz MDBU (Public Safety) 7.04 19W 850MHz & 700MHz LTE Full Band 7.04 19W 1900 MHz MDBU 6.82 20W 1900 MHz MDBU B Path 6.82 20W 2100 MHz MDBU 6.82 12W 2100 MHz MDBU B Path 6.82 12W Blank BIU Module 0.88 - ODU Chassis 19 x 1.75 (1U) x 17.7 12.56 3W OEU Chassis 19 x 3.46 (2U) x 17.7 20.5 12W 4 Port and 1 Port Optical Module (for ODU / OEU) 11.8 x 5.6 x 1.1 3.52 10W Blank Optical Module (for ODU and OEU) 11.8 x 5.6 x 1.1 0.88 - MROU Chassis - AC Power *Fully Loaded 9.84 x 15.94 x 44.14 130 390W MROU Chassis - DC Power *Fully Loaded 9.84 x 15.94 x 44.14 130 390W Add-on remote (AOR) for ROU - AC or DC Power (Required for VHF/UHF Services) 19 x 6.96 (4U) x 10.16 24.25 78W
Standards and Certifications
Specification Description
NFPA 72 Code Compliant National Fire Alarm Code. Applicable for components that can be installed outdoors (e.g., Remote Optic Units and Add-On Remotes).
NEMA 4 This equipment meets NEMA 4 enclosure standards to withstand rain, sleet, snow, dust, dirt, splashing water, and hose-directed water. (Applies only to Remote Optic Units and Add-On Remotes.)
UL (North America) UL 60950-1, 2nd Edition CSA C22.2 No. 60950-1-07, 2nd Edition, CSA C22.2 No. 60950-1-03, 1st Edition
FCC (North America) FCC Part24 Subpart D and Part90 Subpart I FCC Part22 Subpart H and Part 27 Subpart C FCC Part24 Subpart E and Part 27 Subpart C
IC (Canada) RSS-131 (ISSUE 2), ICES-003 Emissions (North America) FCC Part15 Subpart B, Class A MTBF (Telecordia SR-332 Issue2)
Failure Rate = 11,823 MTBF = 9.65 Years
![Page 5: ALLIANCE Multi-Operator DAS - Hutton Communications 5W.pdf · ALLIANCE Multi-Operator DAS 5W Mid-Power Remote Unit (MROU) Product Specification!!!!! ... ALLIANCE DAS – 5W Remote](https://reader034.vdocuments.site/reader034/viewer/2022042502/5b04251f7f8b9aba168cdbe1/html5/thumbnails/5.jpg)
ALLIANCE DAS – 5W Remote Optic Unit (MROU) Product Specification
Version 1.4 – December 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com
Part Numbers Product Description Part Number BIU (Base Station Interface Unit) Signal Source Inputs
Base Station Interface Unit **NOTE: Input Power -48VDC. Power supply not included. BIU_C BIU Combiner (Doubles Input Modules on Single Fiber Strand) BIU_Combiner Blank BIU Module for the BIU BIU_B (BIU Blank) 1900 MHz Input Module for the BIU MDBU_1900P 1900 MHz Input Module for the BIU; B Path for MIMO MDBU_1900P_B 700MHz LTE Full Band MIMO Input Module for the BIU MDBU_700LTE_M 700MHz LTE Full Band SISO Input Module for the BIU MDBU_700LTE_S 800MHz & 900MHz Input Module for the BIU MDBU_800PS_900I_PA 850MHz & 700MHz LTE Full Band Input Module for the BIU MDBU_850C_700FB 850MHz & 700MHz (first responder) Input Module for the BIU MDBU_850C_700PS 2100MHz Input Module for the BIU MDBU_AWS 2100MHz Input Module for the BIU; B Path for MIMO MDBU_AWS_B ALLIANCE Power Supply - 48 VDC / 480 W RMP_480 ODU/OEU Optical Distribution and Expansion Units Optical Distribution Unit Chassis ODU_C Optical Expansion Unit Chassis **NOTE: Input Power -48VDC. Power supply not included. OEU_C 1 Port Optical Module (For TITAN use only) ODU_OM_1 / OEU_OM_1 4 Port Optical Module (For TITAN and ALLIANCE) ODU_OM_4 / OEU_OM_4 Blank Optical Module for the ODU ODU_B / OEU_B MROU and RDU (Mid-Power Remote Optic Unit and Remote Distribution Units) 5 Watt Remote Optical Unit Chassis - AC Power / DC Power MROU_C_M_AC / MROU_C_M_DC 5 Watt Blank Module MROU_B Add-on cabinet for ROU (AOR) - AC Power / DC Power (Required for VHF/UHF Services) ROU_Add-On_AC / ROU_Add-On_DC 5 Watt 1900MHz Amplifier Module MRDU_1900P 5 Watt 700MHz LTE Full Band Amplifier Module MRDU_700LTEF 5 Watt 700MHz LTE Full Band Amplifier Module; B Path for MIMO MRDU_700LTEF_B 5 Watt 700MHz & 800MHz Public Safety Amplifier Module MRDU_700PS_800PS 5 Watt 800MHz iDEN & 850MHz Cellular Amplifier Module MRDU_800I_850C 5 Watt 850MHz Full Band Amplifier Module MRDU_850C 5 Watt 900MHz Amplifier Module MRDU_900I 5 Watt 2100MHz Amplifier Module MRDU_AWS 5 Watt 2100MHz Amplifier Module; B Path for MIMO MRDU_AWS_B 150MHz VHF & 450MHz UHF Amplifier Module RDU_150_450 380MHz VHF & UHF Amplifier Module (Military Band) RDU_E_VHF_UHF Combiner – Required for combining output for 700LTE / 2100AWS MIMO MROU_CU_70B21B Combiner – Required for combining output for 700PS/800PS/900i MROU_CU_708090 DMS (Data Management System) Data Management System (DMS) for ALLIANCE DMS_1200 REL6
SOLiD 617 North Mary Avenue Sunnyvale, CA 94085 PHONE: 888.409.9997 EMAIL: [email protected] WEB: www.solid.com