all india institute of medical sciences, bhubaneswar at ... · all india institute of medical...
TRANSCRIPT
All India Institute of Medical Sciences, Bhubaneswar
At - Sijua (Patrapada), Post - Dumuduma, Bhubaneswar (Odisha) - 751 019
To be uploaded in Website: www.aiimsbhubaneswar.edu.in (Tender)
Reference No: J-ll058(026)/2018-19/S&P Dated: ~02/2019
Sub: Procurement of USG Machine for Urological Procedures (including Laparoscopic intra-
operative Ultrasound) (Make: BK Medical) for the Department of Urology at AIIMS, BBSR on
Proprietary basis - Inviting Comments thereon.
The Department of Urology of AIIMS, Bhubaneswar has requested for Procurement of USG Machine
for Urological Procedures (including Laparoscopic intra-operative Ultrasound) (Make: BK Medical)
from Mis BK Medical (Analogic Ultrasound Group) through their Indian Dealer Mis Healthware
Private Limited.
The Notice is being uploaded for general information of prospective manufacturer/Authorized
Distributor/Dealers to submit their objection/proposal/comments, if any, on proprietorship of the
item.
In case the product of any manufacturer/Authorized distributor/Dealer conforms to the enclosed
specifications, they may submit their proposal for the supply of the same along with the brochures,
point by point compliance of the enclosed specifications along with all documentary evidence. One
quotation of the product may also be submitted.
The objections/comments/proposal should be sent in sealed cover to the Office of Sr. Procurement
Cum Stores Officer, AIIMS, Bhubaneswar (Odisha) - 751019 or through E-mail to
[email protected] & [email protected], so as to reach on or
before date: 09-03-2019 failing which it will be presumed that no other firm is interested to offer
comments/protest/object and case will be decided on its merits.
The ref. no. - J-ll058(026)/2018-19/S&P dt: 23-02-2019, due on dated: 09-03-2019 should be
superscripted on sealed envelope.
Enclosure:
1. Proprietary Article Certificate from Indenting Officer of Department of Urology, AIIMS,
Bhubaneswar. Annexure-I
2. PACof M/s. BK Medical, Denmark Annexure-II
3. OEM's Authorization Certificate stating their Authorized Dealer as M/s Healthware Private
Limited valid up to 31-03-2020 Annexure-III
4. Price Offer for Flex Focus 800 USG Machine for Urological Procedures (including Laparoscopic
intra-operative Ultrasound) Annexure-IV
5. Brochure & Literature of the Product/Equipment Annexure-V
Copy to:
1. Indenting Officer, Department of Urology
2. Accounts Officer
3. IT Cell
for information please
for information please
for hoisting in the website.
¥Sr. Procurement-cum-Stores Officer
~~
Proprietary Article Certificate
Valid for the Current Financial Year
1
~. Vf30,0 0,000
File No. and Date Reference:
Description of article
2 Forecast of quantity /annual requirement
3 i Approximate estimated value for above quantity
4 Maker's name and address
5 Name's of authorised dealers/ stockists -H€1JL-rH W~I
6
I I approve the above purchase on PAC basis and certify that: -
: Note- Tick to retain only one out of (b), C-l) or (c-2) whichever is applicable and cross out others.
Please do confirm (a) by ticking it- without PACcertificate will be invalid.
r This is the only firm who is manufacturing / stocking this item.
I AND
6 (b)A Similar article is not manufactured I sold by any other firm, which could be used
: in lieu
6 (c-l)
, No other make/brand will be suitable for following tangible reasons (like
! OEM/Warranty spares.): OR
1II
.--.!....:=:=====================================================----.-~
: No other make/brand will be suitable forfollowing intangible reasons (if PACwas
I also given in the last procurement cycle, please also bring out efforts made since
I then to locate more sources) :I
6 (c-2)
7Reference of concurrence of finance wing to the
proposal:
I History of PAC Purchase of this item for past three years may be gh, Jl below : ~HL ji Name of the Supplier -----------~--------~-
Orderl Tender Reference & BasicRate on Order '~erse PerformanceQuantity Ordered I MUV
Date _-+- (_R_S._) -.i__ Reported if Any --lr
---~~
~r--__~~~~~-~_-_-_~~ I ~~ / -i~! _._--'
Signature of Approving Authority nR.~ .P.RAYX!. NAY K
UtPT. r: rRDl GY
Date Designation of Officer A-~.I.;,.~ ..•... L'.r..U 2A N E S WAR
TO WHOM IT MAY CONCERN
bk»medical
December 6"', 2018
Dear Sir,
Sub: Proprietary Article Certificate for 8818 - Prostate Triplane Transducer, UA1219 - Vector
Flow Imaging NFl) License and Start stop button/s on 8818 & 8820e transducers.
Analogic Corporation, USA (wherein BK Medical ApS is part of Analogic Corp) who is proven and
reputable manufacturers of various models High End Ultrasound Systems is pleased to confirm the
following:
We are the only company who manufactures;-
• 8818 - Prostate Triplane Transducer
• UA1219 - Vector Flow Imaging (VFI) License
• Start stop button/s on 8818 & 8820e transducers
are being solely manufactured by us having factories at Mileparken 34, DK-2730 Herlev, Denmark
and 8, Centennial Drive, Peabody. MA 01960.
These items are proprietary of BK Medical Aps which is part of Analogic Corporation, USA; no
company in the world is manufacturing such items as of now.
bk ~BK Medical$ . M;ltlparken 34. ) JK-2730 Heriev
d· I Denmark
rnE:' .Iea TeL +4544528100-_ bkmedicar.com
BK Medical' Mileparken 34 • DK-2730 Herlev· Denmark' Fax: +4544528199, Tel: +4544528100' bkmedical.com
To whom it may concern
medical
Date' February 21", 2019
We Analogic Corporation, USA (wherein BK Medical Aps is part of Analogic Corp), who areestablished and reputable manufactures of Advanced Color Doppler Ultrasound Machines having its
facilities and offices at 8, Centennial Drive, Peabody, MA 01960 USA and Mileparken 34, DK-2730Herlev, Denmark,
We hereby authorize Healthware Private Limited, having their registered office at Serene Towers
4th Floor, 8-2-623/A, Road NO.1 0, Banjara Hills, Hyderabad -500 034, to bid, negotiate and conclude
the contract with you against the above project for the goods manufactured by us.
No company or firm or individual other than Healthware Private Limited are authorized to bid, negotiate
and conclude the contract in regard to this business against this specific project.
This certificate is valid up to 31-03-2020.
Kind regards
BK Medical
BK Medical' Mileparken 34 • DK-2730 Herlev - Denmark' Fax +4544528199' Tel. +4544528100' bkrnedical.com
f:::ALTHWARE
Ref: HWPL/S0}2018-19/B-143 zo" February, 2019
TO
The Director
All India Institute of Medical Sciences
AIMS Road, Sijua, Patrapada,
Bhubaneswar 751019, Odisha.
Offer for Flex Focus 800 USG Machine for Urological Procedures (including Laparoscopic intra-operative Ultrasound)
(Make: BK Medical)
Part NO. Description Quantity Price in INR
1202-10 1202 Flex Focus 800 Scanner Unit 1 ~ 1,31,10,992/-
UAl210 Mobile keyboard Dock for 1202 1 Inclusive
UA1206 Dicom option for 1202 1 Inclusive
UA1219 Vector Flow Imaging (VFI) Licence 1 Inclusive
8820E Convex Array Transducer 2.5-6Mhz 1 Inclusive
UA1250 Needle Guide for 8820e 1 Inclusive
8818 Prostate Triplane Transducer 1 Inclusive
UA1328 Reusable Dual Biopsy Guide for 8818 1 Inclusive
8666-RF Laparoscopic Transducer MFI 5/75/10 MHz 1 Inclusive
8670 Linear Transducer 6-12 MHz 1 Inclusive
UA1269 Biopsy Guide to 8670 1 Inclusive
Total system price in words: Rupees One Crore Thirty One lakh Ten Thousand Nine Hundred Ninety Two Only.
Terms & Conditions:
Clause No Clause Name Clause Description
I1 Prices
All prices quoted are for supply F.O.R destination hospital site, Inclusive ofI
Customs Duty, Clearance Charge, Govt. Cess and GST, as applicable.
2 ValidityOur offer would be valid till 31
stMarch 2019. Extension of validity if sought by the
Customer may be considered by us.I
3 OrderingYour order should be placed on us at.. ... :
IHEAlTHWARE PRIVATE LIMITED I8-2-623/A, Serene Towers, Road No # 10,
IBanjara Hills, Hyderabad - 500034.
4 Payment TermsAs per standard terms & conditions of AIIMS Bhubaneswar.
I
), i E
IElEALTHWARE
Bank details:
HDFCBank Limited
6-1-73, Gr. and 3rd Floor, Saeed Plaza, Lakdikapul, Hyderabad 500016.
Account name: Healthware Private Limited
Account type and Number: Current, 00210330001787
IFSC:HDFCOOOO021.
5 DeliveryWithin 10-12 weeks from the date of receipt of your confirmed Order.
If required, Road Permit to be provided by the buyer.
6 Purchaser'sThe purchaser shall be responsible to ensure that properly trained, competent and
responsibilities skilled personnel run the equipment, and only prescribed consumables are used
thereof.
The purchaser shall provide for a suitable, convenient and unrestricted accessfor
the equipment entry to the installation site. The purchaser shall at its cost carry out
any and all civil/structural modifications required towards making such proper site
access and fittings, including all masonry, plumbing, carpentry, electrical/air
conditioning and other requisite facilities. The purchaser shall provide at its
expense a requisite power connections / UPSand all the infrastructure required for
Iinstallation of the equipment including the man power requirements for the proper
I installation of the equipment (as per the technical broachers / data sheets of ours
provided to the purchaser from time to time).
Activities Incidental to installation like unpacking, guidance for erection and
operation demo will be facilitated by us. Activities limited to installation will be
carried out by us subsequent to sale at no extra cost, provided the purchaser
performs its responsibilities herein.
Customer or its representative shall accept the product in the hospital immediately
after installation and upon demonstration of all technical functions, not later than
four days after completion of installation. Acceptance shall be documented by
means of a Final Acceptance Certificate in the Form provided by Healthware, signed
by Customer or its representative and delivered to Healthware Pvt. Ltd [HWPL].
If no Final Acceptance Certificate is signed, acceptance shall be deemed to have
taken place ("Date of Acceptance") on the earliest of
A. The date on which customer first uses the products for treatment of patients, or
B. Six weeks after delivery of the products to the hospital, if acceptance cannot take
place or has not taken place through no fault of our Principals.
All risks of loss or damage to products shall pass to customer upon delivery to the
carrier accordingly to FCAInco terms 1990. Title to the products shall remain with
our Principals until the purchase price is paid in full.
,.HEALTHWARE
7 EnvironmentThe equipment offered can be damaged by dust and extreme changes in
temperature and humidity, and we shall not be liable for damage caused by the
same.
8
9
Safety
Intellectual
property rights
For continued safe and optimum use of this equipment, the purchaser shall strictly
follow the instructions given in the Operators manual. We shall not be responsible
for damages injuries or losses suffered or caused due to, directly or indirectly, non-
compliance with the operator's manual and other related instructions and norms.
The Customer hereby agrees and accepts that we or our principals are not
responsible for any such damage that may occur to any party and the customer
further undertakes to keep us and our principals indemnified from any claims that
may arise out of or in relation to such damage from any party.
It is agreed and acknowledged by the purchaser that in respect of all programs,
software, manuals, know-how, techniques, and other forms of proprietary
information supplied by us through any acceptable media, whether documented or
not, or constituted or contained in the equipment, operating manuals, product data
sheets etc., shall be and remain the sole and exclusive property of us or the
respective owner of such intellectual property, and that the sale of the equipment
along with and such propriety or copyrightable materials supplied by us, shall only
constitute a right to use by the purchaser and shall not amount to transfer of any
such Intellectual property rights in favour of the customer. I
The purchaser undertakes to not make any unauthorized copied, by any means, or
in any manner violate, breach, or infringe any and all or any of the said intellectual
property rights and the customer shall be directly responsible for such a breach.
a) Principals reserve the right to make and design-improvements until the
product is delivered. Such improvement, however, shall not modify any
material aspect of the Product.
b) If any modification to the product is required pursuant to any law or
governmental regulation or requirement or interpretation thereof by any
governmental agency, which is effective prior to the delivery date and
which is applicable to the intended use of the product by the hospital, then
in order to meet such requirement, such modification shall be made prior
to the delivery date.
c) The customer shall pay to us the increased price if any caused by the
modification said above; such price increase however shall be negotiated
and mutually agreed.
10
11
o It'
Modifications
Warranty1. We warrant the equipment (including transducers) against manufacturing I
defects, if any, for a period of 63 months from the date of delivery or 60 Imonths from the date of installation subject to Force Majeure and the
following conditions,
a. This warranty does not cover normal wear & tear, wrongful handling,
not following the user instructions given in the literature and
I-aEALTHWARE
unauthorized attachments or modifications.
b. The warranty clause does not apply for the defects / repairs caused to
the equipment due to negligent actions of and commissions and
omissions by the customer or the representative.
c. The breach of contract conditions like non-payment / delayed payment
of consideration and servicing done by un-authorized persons makes
the warranty conditions voidable at our hands.
d. Opportunity cost and any other indirect costs incurred by the
customer do not fall into the orbit or warranty.
e. The warranty claims what so ever, will be restricted to the value of
goods sold, in case of return of goods by the customer due to
manufacturing defects, if mutually agreed upon.
12 Installation & after-Installation shall be done by our service engineers at no extra charges.
sales serviceAfter Sales Service shall be taken care of by our team of trained Service
Engineers posted at Kolkata.
13 Com prehensiveAfter the warranty period of 5years, the Comprehensive Maintenance Charges
Maintenance (CMe) for the quoted equipment will be as follows,
I Charges(Annual)
ICMC Charges Amount in Rupees (Excluding GST @ 18%)
6th Year ~ 5,15,013.00
7th Year ~ 5,40,764.00
8th Year ~ 5,67,802.00
9th Year ~ 5,96,192.00
10th Year ~ 6,26,001.00
Please note that the GST @ 18% extra will be applicable on the quoted CMC
charges.
14 Claim in case ofa) in the event of any defect (against which the above warranty is provided)
defective being found on the equipment on reaching the destination /site and
equipment thereafter within the warranty period set out above, replacement or repair
will be carried out within 45 working days from the date of receipt of
written notice of such defect by us.
The warranty conditions replicate for defective equipment also.
b) if we do not have in our stock any equipment or components to replace the
defective equipment or components thereof then the time taken to
manufacture or to obtain supplies from our suppliers shall be in addition to
the said period of 4S working days without any liability to us.
,.HEALTHWARE
15 Force majeureWe shall not be liable for loss or damage due to delays caused by force majeure
conditions and any failure of or delay in the performance of this Agreement for the
period that such failure or delay is due to causes beyond its reasonable control,
including but not limited to acts of God, war, strikes or labour disputes, embargoes,
government orders, natural calamities or any other force majeure event.
16 ArbitrationAny difference or dispute arising out of or any reconciliation to these standard
trading terms and conditions shall be referred to arbitration. The arbitration shall
be conducted in accordance with the Arbitration and Reconciliation Act, 1996 and
the venue of the arbitration shall be at Hyderabad. The arbitration shall be presided
by a sole arbitrator to be appointed by us.
17 Limitation ofIn no event will company be liable to you for any lost profits, lost savings or
Liability incidental, indirect special or consequential damages, arising out of your use or
inability to use the product or the breach of this agreement, and violation of user
manual conditions even if advised of the possibility of such damages.
18 Deeming clauseThe purchase order placed by the customer in response to the quotation is deemed
to have accepted the terms and conditions attached to the quotation except to the
extent, contrary conditions imposed if any in the customer order.
The contrary conditions if any imposed in the customer order require negotiation
and acceptance.
19 Jurisdiction andWithout prejudice to the arbitration clause any litigation that may arise out of or in
applicability of Lawrelation to this Agreement including but not limited to any application under
Section 9 and 11 of the Arbitration and the Conciliation Act of 1996 shall be dealt
by the Courts in Hyderabad only in exclusion of all other courts. The Agreement
shall be governed by the Laws of the Union of India and the State of Telangana.
With best regards,
For Healthware Private Limited
(Authorized Signatory)
uorr 18f
----
I-IIEALTHWARE
Annexure-l
Price list of Transducers & Biopsy-attachments/needle-guides
mentioned in
Ref: HWPL/SQf2018-19/B-143 dated zo" February, 2019
Part NO. Description Quantity Price in USD
8820E Convex Array Transducer 2.5-6Mhz 1 $ 13,000.00
UA1250 Needle Guide for 8820e 1 $ 1,200.00
8818 Prostate Triplane Transducer 1 $ 23,000.00
UA1328 Reusable Dual Biopsy Guide for 8818 1 $ 250.00
8666-RF Laparoscopic Transducer MFI 5/75/10 MHz 1 $ 29,000.00
8670 Linear Transducer 6-12 MHz 1 $ 13,000.00
UA1269 Biopsy Guide to 8670 1 $ 1,400.00
NOTE:The prices listed are on CIF terms to be delivered at an international airport in India.
The prices quoted are exclusive of custom duty, and all other taxes and duties imposed by any Local
bodies, State Govt., Central Govt., Union territory in India. The consignee will do the Custom
Clearance of the shipment, in case of a Euro order.
In case of INR order, the USD value of the ordering date will be taken into consideration for USD to
INR conversion and appropriate duties, clearance charge, Govt. Cess & GST, will be applicable extra.
For Healthware Private Limited
(Authorized Signatory)
bkultrasound
powered by analogic •
Urology
T e Gold Standard i
Urology Ultrasound Imaging
Unique Triplane Prostate Imaging
Premium I ag s for Urology
Unparalleled Image Quality
• Innovative Quantum Technoloqy'"
• Unique Triplane Prostate Imaging
Exclusive Precision BiopsyTechnique
Comprehensive Range of Sterilizable Urology Transducers
I
Advance Diagnostic Confidence with Premium Urology ImagingHigh-end urology imaging with fully featured premium performance ultrasound systems
and innovative Quantum Technology
•..•~III'\..,·"'1Pr t:. maaina
Quantum Technology offers advanced contrast resolution
and gray scale maps for unparalleled prostate images. View
real-time prostate images in sagittal and transverse planes
for faster examinations and biopsy procedures. Perform
more confident biopsies using the unique triplane
transducer with simultanous biplane and endfire imaging
capabilities. Superior needle guidance with convenient
sterile, single-use needle guides.
Premium K" t:. stes ImaainRI~lddpr
Superb image quality for advanced kidney imaging, mea-
surement and biopsy. Seeanatomical details and variations,
measure flow and find kidney stones. Visualize blood flow in
testes and the penile arteries with highly sensitive
color Doppler.
obotic-A slst ur r
Achieve control, precision and premium performance ultra-
sound imaging. High resolution imaging controlled directly
from surgeon's console. Full command of system functions,
including Doppler. Easyplug-and-play DVI for seamless
integration of images into Tilel'ro?". Superior high resolu-
tion 2D, 3D and color performance. Unique 3D rendering
and visualization in RAPNand RARPprocedures.
Ultrasound-Gutded Pros ate en "ons
Manage treatment of prostate patients with greater con-
fidence using ultrasound guided prostate brachytherapy
and cryotherapy techniques. Advanced imaging features,
dedicated transducers, and measurement and calculation
packages help differentiate, visualize and quantify tissue
structures and changes more efficiently. Brachytherapy
tools, including the biplane transducer and connection to
planning systems, enable smooth workflow and more
confident treatment.
1 Trademark of Intuitive Surgical, Inc.
Prostate Triplane
8818Prostate 8iplane
8808e
Endlire
86673DART
8838
Innovative transducers for superb prostate imaging.
Curved Array Curved Array Curved Array Linear Array Linear Array
8820e 8823 8830 8811 8870
Versatile transducers for outstanding abdominal imaging.
Advanced linear array transducers provide wide tieid of view.
ProART'"
88263DART'"
8838
e.
ProART (Drop-in) transducer gives superb control, maneuverability, and optimal
acoustic contact. 3DART is the world's tirst high resolution 3D prostate transducer.
L Endocavity Biplane
8848
T J 'e s fo UI 'Q oi.nd-Gu ded Therapies
Designed for precision, convenience, and gold-standard prostate imaging,
;
69A'. . d (I·· II f 0 30 v) coustic an rruca nnovators or ver rearsRecognized as a global leader in the development of ultrasound systems designed for urology,
BKUltrasound offers a versatile range of state-of-the art imaging systems, Quantum Technology,
and dedicated transducers to help enhance diagnostic confidence and advance the care of patients.
Quantum Technology
System versions available: flex Focus'" 800, flex Focus 500, flex Focus 400
flex Focus M Family
Direct Sales Offices
BK Ultrasound
8 Centennial Drive
Peabody
MA 01960
U5A
T + 1 978-326-1300
F + 1 978-326-1399
bkultrasound.com
Analogic Benelux N.V. BK Medical ApS bk medical Medizinische
Systeme GmbH
Pascalkehre 13
25451 Quickborn
Germany
T +494106 99 55-0
F +494106 99 55-99
bkultrasound.com
Generaal de Wittelaan 19B bus 7
2800 Mechelen
Belgium
T +3215280600
F +3215 291025
bkultrasound.com
Mileparken 34
2730 Herlev
Denmark
T +45 4452 8100
F +45 4452 8199
bkultrasound.com
Analogic Italia S.r.I. B-K Medical AB BKMedical
Via Morandi, 10
20077 Melegnano MI
Italy
T +39 02907813 47
F+390290781905
bkultrasound.com
Mzmskarsvagen 9
14175 Kungens Kurva
Sweden
T +46 8-744 0211
F+468-7440212
bkultrasound.com
Unit A20/A20a
Basepoint Business & Innovation Centre
110 Butterfield, Great Marling.
Luton Bedfordshlre LU2 8DL
United Kingdom
T +44 1582433710
F +44 1582433716
bkultrasound.com
••• BK Medical Ap5, Mileparken 34, 2730 Herlev, Denmark. T +45 4452 8100 F +45 4452 8199
.bkultrasound
powered by onologic •
BK Ultrasound
8 Centennial Drive
Peabody
MA01960
USA
T + 1 978-326-4000
bkultrasound.com
Sales and Service USA
BK Ultrasound
8 Centennial Drive
Peabody
MA 01960
USA
T + 1 978-326-1300
F + 1 978-326-1399
bkultrasound.com
Europe and Rest of World
BK Ultrasound
Mileparken 34
2730 Herlev
Denmark
T +45 4452 8100
F +4S 4452 8199
bkultrasound.com
Asia
Analogic Medical Equipment
(Shanghai) Co., Ltd.
1377, Lan Dian Road,
Pu Dong New District,
Shanghai, China 201132
bkultrasound.com
U'\
.•...M
o
u
8U'\
o\:l<Xl
•.The name Analogic is a registered trademark of Analogic Corporation. The globe logo is a trademark of Analogic Corporation .
bk medicaL flex Focus 800
A Quantum Leap in
Imaging Performance
Premium, Comprehensive and Flexible
• High Resolution Imaging for Your Clinical Needs
• Advanced Imaging Technologies
• Extreme Maneuverability in a Compact Design
• Extensive Portfolio of Innovative Transducers
Advance Your Imaging Performance
High Resolution Imaging
• Premium performance with efficiency and speed
• High resolution 19/1 monitor
• Excellent Color Doppler with superb spatial
resolution and sensitivity
Advanced Imaging Technologies
• Motion Compensated Angular Compound
Imaging (MACI)ensures high quality real-time
images using camera imaging technology
• Automatic Mode Adjustment (AMA) optimizes
high resolution B-Mode imaging when
changing modes and depth
• Triplex enables you to maximize PRFwith a tight
spectral envelope and real-time synchronicity
between 2D and Color Doppler
Extremely Maneuverable and Easyto Use
• Small footprint - fits in the tightest spaces
• Four hours plug-free imaging
• Innovative, intuitive user interface
• Smooth, sealed keyboard for easycleaning
and disinfection
State-of-the-Art Transducers for Your
Clinical Needs
• lnnovative design for accessto all areas
• Advanced puncture guides
• Convenient one-button control
• Easysterilization and disinfection
General ImagingExceptional image quality,
intuitive user interface and
advanced workflow features
enable high quality abdominal,
small part and vascular imaging.
Unique Vector Flow Imaging mode'
enables angle independent
visualization of blood flow.
* Vector Flow Imaging is not licensed by Health
Canada and is not market cleared by the FDA
for use in the USA.
SurgeryThe gold standard in surgical
ultrasound. Precise visualization.
Sharp laparoscopic, intraoperative
and percutaneous images.
Comprehensive range of dedicated
surgical and neurosurgical
transducers. Simple to clean.
Robotic-Assisted Surgery
Premium performance robotic
ultrasound solution. Wireless
remote control and dedicated
transducers for uncompromised
image quality and control.
Unique 3D visualization.
UrologyExcellent detail and contrast
resolution for kidney imaging.
Superb spatial resolution and
sensitivity in Color Doppler.
Comprehensive range of
I transducers for prostate biopsy
and treatment guidance.
Walk Up and Use
Full-featured system is
exceptionally intuitive.
Easy setups - walk up and use.
Innovative touch screen and
simple touch pad.
~l}nOvative Transducers Designed for Your Clinical NeedsFor over three decades, healthcare providers have looked to BK Medical for innovative ultrasound
solutions. Our state-of-the-art transducers provide one-button control, easy-to-use puncture guides
and compatibility with modern disinfection and sterilization techniques to further advance the care
of your patients.
I-Shaped
Intraoperative
8815
ProARTRobotic
Drop-In
8826**
10-5 MHz
T-Shaped
Intraoperative
8816
Biplane
Intraoperative
8824
Craniotomy
8862**
10-5 MHz
Burr-hole 'Hockey Stick' Biplane
Intraoperative
8814
Anorectal 3D
2052
16-6 MHz10-4 MHz 10-4 MHz 10-5 MHz
8863** 8809
15-{;MHz 10-5 MHz
\4-Way Rigid Curved Array Curved Array Curved Array Curved Array Linear Array Linear Array High Frequency
Laparoscopic Laparoscopic Linear Array
8666-RF 8836*** 8823 8820e 8830 8802 8811 8670 8870
10-5MHz 12-5 MHz 6-1.8 MHz 6-2 MHz 6-2 MHz 6-3 MHz 12-5 MHz 12-4 MHz 18-{;MHz
10-5 MHz
Vascular
8822**
9-3.5 MHz
•
ProstateTriplane Prostate
Biplane
8808e
3DART
8818 8838**
12-4 MHz 10-5 MHz 12-4 MHz
•• Not licensed by Health Canada
••• For future release
Sales Offices
B-K Medical Benelux NV/SA
Generaal de Wittelaan 19/B
2800 Mechelen, Belgium
Tel: +32 15280600
Fax: +32 15291025
Email: [email protected]
B-K Medical Medizinische
Systeme GmbH
Pascalkehre 13
2S451 Quickborn, Germany
Tel: +49 41 069955-0
Fax: +49 410699 55-99
Email: [email protected]
Via Tulipani, 1
20090 Pieve Emanuele MI, Italy
Tel: +39 02 90 781347
Fax: +39029078 1905
Email: [email protected]
Manskarsvagen 9
14175 Kungens Kurva, Sweden
Tel: +46 8-744 0211
Fax:+468-7440212
Email: [email protected]
11 Grove Park
Waltham Road,
White Waltham, Berkshire
SL6 3LW United Kingdom
Tel: +44 1628 82S-770
Fax: +44 1628826-970
Email: [email protected]
Endocavity
Biplane
8848
12-4 MHz
Endovaginal
8819
9-5 MHz
+
B-K Medicale S.r.I.
Endfire Curved
Array
8667
Small footprint
Cardiac
8837***
Small footprint
Cardiac
8827
10-5 MHz 4-2 MHz 4-2 MHz
B-K Medical AB B-K Medical (UK)
•• BK Medical ApS, Mileparken 34, DK-2730 Herlev, Denmark. Tel.:+45 44528100 Fax:+45 44528199 Email: [email protected]
Innovative Solutions for LifeAnalogic Corporation creates innovative technology to improve the health and ensure the safety of
people around the world. We are committed to providing ultrasound solutions under the BKMedical
brand name that advance medicine and save lives.
Analogic Corporation - Headquarters USA
8 Centennial Drive, Peabody, MA 01960
T. 978- 326-4000
analogic.com
BK Medical- Sales and Service USA
8 Centennial Drive, Peabody, MA 01960
T. 978-326-1300
bkmed.com
The name Analogic is a registered trademark of Analogic Corporation. The globe logo is a trademark
of Analogic Corporation.
BK Medical- Europe and Rest of World
Mileparken 34, DK-2730, Herlev, Denmark
T: +45 4452 8100
F: +45 44S2 8199
bkmed.com
Analogic
Ultrasound •bk medicaL
VFI - Technology to
Change the Way You Work
Vascular Ultrasound Made Easier
Vector Flow Imaging - VFI
VFI is a ground-breaking technology that can revolutionize the workflow for many Doppler ultrasound applications.
In addition to revealing flow pattern details, it saves valuable time and makes the exam much easier.
The new proprietary VFI method visualizes blood flow in all directions, independent of imaging angle.
VFI and VFI Assist
• A good overview of flow
• Visual representation of flow in all directions - including turbulence and transvei se flow
• Angle-independence
• Faster - gives an overall hemodynamic view without having to steer
• More consistent results -less clinician dependent
• Streamlined vascular procedures to potentially save time.
Automatic functions include:
• Placing PW Doppler gate at highest velocity
• Selecting best steering angle
• Showing real-time Flow Velocity
Showing real-time Volume Flow
Conventional CFM before angling
and steering of the beams
VFI
VFI
Measuring Flow Velocity
VFI Assist Flow Velocity Measurements
Flow velocity information is often needed in exams, e.g. to exclude carotid artery stenosis and plaque, or leg exams
to exclude DVT (Deep Vein Thrombosis). Measuring flow velocity requires a skilled sonographer and usually needs
the following 5 steps (and 3 for every new location).
Using the automated functions in VFIAssist, the workflow only requires 2 steps and it is updated at all times, even
when the transducer is moved.
3. Select steering
direction
4. Move the gate to find
the highest velocity
5. Angle correct the
gate
Easyas 1,2,3
Scan Long Axis of Artery Press Color On Press PW Doppler On
Page 2 VFI - Technology to Change the WayYou Work
VFI
Measuring Volume Flow
VFI Assist Volume Flow Measurements
The benefits ofVFI Assist are even more pronounced when measuring volume flow (VF). In this situation,
the workflow to obtain VF is reduced from 12 steps (for aVFon a frozen image - and 12 more for every new
location) to 2 steps (and one for every new location) shown in real-time.
1-5. Flow Velocity steps
6. Open up the gate to encompass
entire vessel
7. Freeze TriplexlPW image
8. Measure the diameter of vessel
11. To measure Time Average Mean
velocity (TAM) - place the first vertical
cursor at the beginning of the cardiac
cycle
12. Place the second vertical cursor at
the end of the third cardiac cycle
. -
1. Press Update
-. .•. .
. ~ . . .•..... . . .•.
VFI Assist Volume Flow
VFI - Technology to Change the WayYou Work Page 3
VFI
A Clinical Use - Hemodialysis
Monitoring the flow at vascular access site
The increase in number of patients undergoing hemodialysis
highlights the need for improved methods of monitoring
vascular flow.
Thrombosis is a common complication of hemodialysis; it is
essential to monitor the flow in the vascular accessto ensure
that it is below 600ml/min for a fistula and 400ml/min for a
graft. Vascular accessfailure is the most frequent cause of
hospitalization for patients with chronic renal disease (Cairoli
OM 2004).
One popular way to assessthe patency of the dialysis graft is
to use ultrasound and measure the volume flow.
VFIAssist streamlines the process of obtaining flow
data and can minimize time consuming adjustments. VF
measurements can easily be made at different locations to
potentially increase the quality of the evaluation.
It is an alternative to other flow measurement methods and
supports the trend of increased use of ultrasound in daily
clinical practice.
Hemodiolysis Terms
Hemodialysis:
Treatment for renal failure in which circulating blood is diverted through a dialyzer
that acts as an artificial kidney to filter out toxins before the blood is returned to the
body.
Vascular access:
Site where blood leaves and reenters the body. There are two main types of AV
(arteriovenous) vascular access:
1. Fistula - Artery connected directly to vein
2. Graft - Artery connected to vein by a tube
VFIAssist guides you through the workflow. You can also
override any of the automatic adjustments, if changes to the
diameter or the angle of flow need to be made.
The measurement calipers for the diameter can also
be adjusted manually
Color coding and/or arrows are used to show VFI Volume Flow AV Fistula
the size and direction of the flow
Page4 VFI - Technology to Change the Way You Work
@.VFI
VFI - Transverse Oscillation Technology
VFI usesa technique called transverse oscillation to overcome the angle limitations of ordinary Doppler ultrasound. It
creates an effective component of the ultrasound oscillation perpendicular to the transmitting beam - an oscillation in
the transverse direction (Jensen JA 2001; Jensen JA, Munk P 1998).
VFI generates a 20 interference pattern in the received ultrasound signal. This allows the system to calculate not only
the axial component of the velocity (astraditional Color Doppler), but also the transverse component.
This eliminates the angle dependence and enables both the detection and visualization of complex flows.
Traditional Color Doppler VFI
Oscillations in the axial direction gives
a frequency shift in this direction
Oscillations both in the axial and the transverse
directions gives frequency shifts in both
directions
--..t-
<
~7iV transverse
Page6 VFI - Technology to Change the WayYou Work
VFI
VFI - Why and How
Angle Limitations of Doppler Flow Measurements
Ordinary Color and Spectral Doppler ultrasound measure the velocity of flow components toward or away from the
transducer. It usesthe angle of the ultrasound beam relative to the flow direction to calculate the actual flow velocity through
the vessel.
The accuracy of this computation depends on precise knowledge of the direction of the ultrasound beam and direction of
the flow in the vessel (and the angle 0 between them).
When the ultrasound beam is perpendicular to the vessel (90°),this computation
is impossible, because there is no flow component in the direction of the beam.
In effect, the measurement is impossible when the insonation angle is over
60°, because then small errors in measuring the two directions lead to large
discrepancies in the results.
The ground breaking new VFItechnology addresses this problem by eliminating
angle-dependence.
VFI frees you from angle dependence
"
" Vector Flow Imaging is an
excellent method for revealing
the full complexity of human
hemodynamics. Clinical scans have
in real-time given us a wealth of
information about vortices and
other complex flow in the human
circulation
Doppler Velocity Calculation
F 'cV= 10
2' t: cas a
fa = Transmitted frequency
fD = Doppler frequency
(received)
c = Speed of sound in blood
o = Doppler angle (when 0=90°,
cas 0=0)
Jerqen Arendt Jensen, Professor, Ph.D., Dr. Techn.
VFI was developed in conjunction with the Center
for Fast Ultrasound Imaging at the Technical
University of Denmark.
VFI - Technology to Change the WayYou Work Page 7
VFI
• Cairoli, OM
Routine Ultrasound Studies of the Vascular Access in a Dialysis Center: A Review.
Hemodia//nt 2004; 8: 78-79. doi: 10.1111 /j.1492-7535.2004.0085b.x
References
• Jensen JA
A new estimator for vector velocity estimation IEEETrans U/trason Ferroe/ectr Freq
Contro/2001; 48 (4): 886-894.
• Jensen JA, Munk P
A new method for estimation of velocity vectors. IEEETrans U/trason Ferroe/ectr
Freq Contro/1998; 45 (3): 837-51.
Analogic Ultrasound B-K Medical Benelux N.V. BKMedical 8-K Medical Medizinische
Systeme GmbH
Pascalkehre 13
25451 Quickborn
Germany
Tel +49410699 55-0
Fax +49 41069955-99
B-K Medlcale s.u, B-K Medical AB BKMedical
Direct Sales Offices
8 Centennial Drive
Peabody
MA 01960
U5A
Tel + 1 978-326-1300
Fax + 1 978-326-1399
Generaal de Wittelaan 19B bus 7
2800 Mechelen
Belgium
Tel +32 15280600
Fax +32 15291 025
Mileparken 34
2730 Herlev
Denmark
Tel +45 4452 8100
Fax +45 4452 8199
Via Tulipani, 1
20090 Pieve Emanuele MI
Italy
Tel +3902907813 47
Fax +39 02 90 78 1905
Mtlnskarsvagen 9
141 75 Kungens Kurva
Sweden
Tel +46 8-744 0211
Fax +46 8-744 0212
Unit A20/A20a
Basepoint Business & Innovation Centre
110 Butterfield, Great Marlings
Luton Bedfordshire LU2 8DL
United Kingdom
Tel +44 1582433710
Fax +44 1582433716
•• BK Medical ApS, Mileparken 34, 2730 Herlev, Denmark. Tel +4544528100 Fax +45 4452 8199
Analogic Corporation
(Headquarters)
8 Centennial Drive
Peabody
MA01960
USA
Tel + 1 978-326-4000
analogic.com
Analogic Ultrasound
(Headquarters North America)
8 Centennial Drive
Peabody
MA 01960
USA
Tel + 1 978-326-1300
Fax+ 1 978-326-1399
analogicultrasound.com
Analogic Ultrasound
(Headquarters Europe and Rest of World)
BK Medical
Mileparken 34
2730 Herlev
Denmark
Tel +4S 4452 8100
Fax+45 4452 8199
analogicultrasound.com
The name Analogic is a registered trademark of Analogic Corporation. The globe logo is a trademark of Analogic Corporation.
-