all dielectric self supporting 398678 0

1
• Up to 144 fibers • High resistance to tracking effect provides long operating lifetime • SZ stranding design allows for easy mid-span access and isolates fibers from installation and environmental rigors • Drycore design for excellent water blocking performance and easier handling • Minimized additional loads due to small diameter and lightweight with the high strength aramid yarns • Custom designs available *** • Complies with IEEE P-1222, the recognized standard for ADSS cable *** The sheath material (MDPE or TRPE) and the location of the cable on structures that support 110KV or higher circuits should be reviewed prior to installation. LOOSE TUBE ADSS CABLE_AERIAL SAMSUNG’s ADSS Cables are designed for installation on wooden poles, concrete poles or lattice towers along power lines, railways or telecommunication links. As the cable does not contain any metallic elements, it is to be installed on medium and high voltage lines, to prevent dry-band arcing. Track resistant sheath material and software to calculate optimum placement on the towers make this cable usable for line voltages of up to 400 KV. SAMSUNG OPTICAL CABLE All Dielectric Self-Supporting Cable Gel-filled buffer tube Colored optical fiber Dielectric central member Water swellable tape Water swellable yarn Inner jacket Dielectric strength member Outer jacket *** Drawings are not to scale. SINGLE JACKET TYPE Fiber Count 2~36 2~72 74 ~ 96 144 Outer Diameter (mm) 11.4 12.2 13.9 15.8 Cable Weight (kg / km) MDPE 100 114 147 192 TRPE 107 122 156 201 Maximum operating load (kN) 4 4 4 6 Maximum breaking load (kN) 13.0 13.6 14.0 15.4 Minimum bending radius (mm) Short term (loaded): 15*OD 171 183 209 237 Long term (installed): 10*OD 114 122 139 158 Temperature (°C) Operation / Storage -40 ~ +70 Installation -20 ~ +70 DOUBLE JACKET TYPE Fiber Count 2~36 38 ~ 72 Outer Diameter (mm) 12.9 14.1 15.3 16.2 13.8 14.8 15.8 16.8 Cable Weight (kg / km) MDPE 128 151 176 199 144 166 189 212 TRPE 137 161 186 210 154 176 200 224 Maximum operating load (kN) 4 12 20 28 4 12 20 28 Maximum breaking load (kN) 13.4 35.7 59.9 82.8 14.0 35.1 58.1 81.0 Minimum bending radius (mm) Short term (loaded): 15*OD 194 212 230 243 207 222 237 252 Long term (installed): 10*OD 129 141 157 162 138 148 158 168 Temperature (°C) Operation / Storage -40 ~ +70 Installation -20 ~ +70 Fiber Count 74 ~ 96 98 ~ 144 Outer Diameter (mm) 15.4 16.3 17.3 18.1 19.2 19.9 20.7 21.4 Cable Weight (kg / km) MDPE 180 202 225 247 280 302 323 345 TRPE 190 213 237 260 293 316 338 360 Maximum operating load (kN) 4 12 20 28 8 16 24 32 Maximum breaking load (kN) 13.2 35.5 58.5 81.5 23.1 46.5 69.5 92.6 Minimum bending radius (mm) Short term (loaded): 15*OD 231 245 230 272 288 299 311 321 Long term (installed): 10*OD 154 163 157 181 192 207 207 214 Temperature (°C) Operation / Storage -40 ~ +70 Installation -20 ~ +70 Tested in accordance with IEC 60794-1 NOTE • Fiber colors by IEC60304 - Blue / Orange / Green / Brown / Grey / White / Red / Black / Yellow / Violet / Pink / Aqua • Diameter represents a nominal value and may vary by ± 5%. • Sheath marking legend - hot foil stamp (indented) Ex) Manufacturing year (ex. 2013) SAMSUNG ADSS SM 24 = length marking = Single Jacket Type Double Jacket Type CABLE PROPERTIES © 2013 Samsung Electronics Co. Ltd. All rights reserved. Samsung Electronics reserves the right to modify the design, packing, specifications and features shown herein, without prior notice or obligation. www.samsung.com/global/business/fiberoptics

Upload: shafeek-ghreeb

Post on 01-Oct-2015

216 views

Category:

Documents


2 download

DESCRIPTION

All Dielectric Self Supporting

TRANSCRIPT

  • Up to 144 fibers

    High resistance to tracking effect provides long operating lifetime

    SZ stranding design allows for easy mid-span access and isolates fibers from installation and environmental rigors

    Drycore design for excellent water blocking performance and easier handling

    Minimized additional loads due to small diameter and lightweight with the high strength aramid yarns

    Custom designs available ***

    Complies with IEEE P-1222, the recognized standard for ADSS cable*** The sheath material (MDPE or TRPE) and the location of the cable on structures that support 110KV or higher circuits should be reviewed prior to installation.

    Loose Tube ADss CAbLe_AeriALSAMSUNGs ADSS Cables are designed for installation on wooden poles, concrete poles or lattice towers along power lines, railways or telecommunication links. As the cable does not contain any metallic elements, it is to be installed on medium and high voltage lines, to prevent dry-band arcing. Track resistant sheath material and software to calculate optimum placement on the towers make this cable usable for line voltages of up to 400 KV.

    SAMSUNG OPTICAL CABLE

    All Dielectric Self-Supporting Cable

    Gel-filled buffer tube Colored optical fiber Dielectric central member Water swellable tape Water swellable yarn Inner jacket Dielectric strength member Outer jacket

    *** Drawings are not to scale.

    singLe JACkeT TypeFiber Count 2 ~ 36 2 ~ 72 74 ~ 96 144

    Outer Diameter (mm) 11.4 12.2 13.9 15.8

    Cable Weight (kg /km)MDPE 100 114 147 192

    TRPE 107 122 156 201

    Maximum operating load (kN) 4 4 4 6

    Maximum breaking load (kN) 13.0 13.6 14.0 15.4

    Minimum bending radius (mm)

    Short term (loaded): 15*OD 171 183 209 237

    Long term (installed): 10*OD 114 122 139 158

    Temperature (C)Operation / Storage -40 ~ +70

    Installation -20 ~ +70

    DoubLe JACkeT TypeFiber Count 2 ~ 36 38 ~ 72

    Outer Diameter (mm) 12.9 14.1 15.3 16.2 13.8 14.8 15.8 16.8

    Cable Weight (kg /km)MDPE 128 151 176 199 144 166 189 212

    TRPE 137 161 186 210 154 176 200 224

    Maximum operating load (kN) 4 12 20 28 4 12 20 28

    Maximum breaking load (kN) 13.4 35.7 59.9 82.8 14.0 35.1 58.1 81.0

    Minimum bending radius (mm)

    Short term (loaded): 15*OD 194 212 230 243 207 222 237 252

    Long term (installed): 10*OD 129 141 157 162 138 148 158 168

    Temperature (C)Operation / Storage -40 ~ +70

    Installation -20 ~ +70

    Fiber Count 74 ~ 96 98 ~ 144

    Outer Diameter (mm) 15.4 16.3 17.3 18.1 19.2 19.9 20.7 21.4

    Cable Weight (kg /km)MDPE 180 202 225 247 280 302 323 345TRPE 190 213 237 260 293 316 338 360

    Maximum operating load (kN) 4 12 20 28 8 16 24 32

    Maximum breaking load (kN) 13.2 35.5 58.5 81.5 23.1 46.5 69.5 92.6

    Minimum bending radius (mm)

    Short term (loaded): 15*OD 231 245 230 272 288 299 311 321

    Long term (installed): 10*OD 154 163 157 181 192 207 207 214

    Temperature (C)Operation / Storage -40 ~ +70

    Installation -20 ~ +70

    Tested in accordance with IEC 60794-1

    noTe Fiber colors by IEC60304 - Blue / Orange / Green / Brown / Grey / White / Red / Black / Yellow / Violet / Pink / Aqua Diameter represents a nominal value and may vary by 5%. Sheath marking legend - hot foil stamp (indented)

    Ex) Manufacturing year (ex. 2013) SAMSUNG ADSS SM 24 = length marking =

    Single Jacket Type

    Double Jacket Type

    CABLE PROPERTIES

    2013 Samsung Electronics Co. Ltd. All rights reserved.Samsung Electronics reserves the right to modify the design, packing, specifications and features shown herein, without prior notice or obligation.

    www.samsung.com/global/business/fiberoptics