alcatel-lucent omnipcx enterprise communication...

14
Alcatel-Lucent OmniPCX Enterprise Communication Server NPRAE

Upload: vuongdien

Post on 02-Apr-2018

392 views

Category:

Documents


14 download

TRANSCRIPT

Page 1: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

Alcatel-Lucent OmniPCX EnterpriseCommunication Server

NPRAE

Page 2: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

Legal notice:

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks ofAlcatel-Lucent. All other trademarks are the property of their respectiveowners.

The information presented is subject to change without notice.

Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.

Copyright © 2012 Alcatel-Lucent. All rights reserved.

The CE mark indicates that this product conforms to the following CouncilDirectives:- 2004/108/EC (concerning electro-magnetic compatibility)- 2006/95/EC (concerning electrical safety)- 1999/5/EC (R&TTE)

Page 3: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

Chapter 1Hardware description

Overview .................................................................................................... 1.1

Environment ............................................................................................. 1.1

Functional Units ..................................................................................... 1.2

Chapter 2Hardware configuration

Reference .................................................................................................. 2.1

Overview .................................................................................................... 2.1

Strappings ................................................................................................ 2.1

Meaning of LEDs .................................................................................... 2.3

Chapter 3External connections

Connection ............................................................................................... 3.1

Board Output Pins ................................................................................. 3.2

0-1

Page 4: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

0-2

Page 5: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

1.1 Overview

The NPRAE (New Primary Rate Access E1) board replaces the PRA2 board.

This board can be used to connect an Alcatel-Lucent OmniPCX Enterprise CommunicationServer to:

- Another Alcatel-Lucent OmniPCX Enterprise CS in a private network (ABC-F, Q-SIG)

- A non Alcatel PBX in a private network (DPNSS)

- A public network (ISDN, DASS2)

The NPRAE board can provide either:

- Two E1–CCS (T2) accesses

- One DASS2 access (as of R6.1)

- One DPNSS access (as of R6.1)

Note:

For DASS2 and DPNSS, access 0 is the only access available.

At initialization, binaries are sent according to the type of board declared on the PCX. Thesetypes are:

- NPRAE for E1-CCS

- DASS2E for DASS2

- DPNSSE for DPNSS

Clock synchronization can be obtained from the board access if needed to synchronize thenode.

NPRAE board configuration is described in NPRAE - Hardware configuration .

NPRAE board connection is described in NPRAE - External connections .

1.2 Environment___change-begin___

1-1

Page 6: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

___change-end___

Figure 1.1: NPRAE Board Input/Output Diagram

1.3 Functional Units

The NPRAE board is composed of the following functional units:

- 1 switching module

- 2 ISDN E1 interfaces

Chapter 1

1-2

Page 7: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

2.1 Reference

NPRAE board reference: 3BA23254AA.

2.2 Overview

This board is equipped with an FA1 fuse (3 Amperes, 125 VDC) to protect board power supplyagainst overvoltages.___change-begin___

___change-end___

Figure 2.1: View of the NPRAE Board with Straps

2.3 Strappings

Strappings shown on a gray background are factory set

2-1

Page 8: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

___change-begin___

___change-end___

Strap JX6 indicates to the management application which type of configuration (120 or 75ohms) to use.___change-begin___

___change-end___

Straps JX13 and JX23 connect TXB-1 and TXB-2 to ground for 75 ohm terminations.Straps JX14 and JX24 connect RXB-1 and RXB-2 to ground for 75 ohm terminations.Straps JX15 and JX25 adapt the interface to the terminations (75 or 120 ohms).___change-begin___

___change-end___

___change-begin___

Chapter 2

2-2

Page 9: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

___change-end___

2.4 Meaning of LEDs

Figure 2.6: NPRAE Board Front Panel

Under CPU/BSY line, the first column of LEDs gives information on the DASS2, DPNSS or firstE1 link, the second column gives information on the second E1 link.

table 2.1: Summary TableLED Meaning Explanation

CPU (green LED) Processor activity indicator

BSY (orange LED) Trunk activity indicator (for atleast one trunk)

LOS Loss of frame alignment After detecting incorrect framealignment.

AIS Alarm Indication Signal (2 Mbitsalarm signal)

Incoming signal is an unframed bitstream with constant ’one’.

RAI Remote Alarm Indication Distant line end signalizes an alarm.

NOS Loss of Signal Input signal has an insufficient bit rateor an insufficient density of ones.

Note:

No led is available for CRC error ratio.

table 2.2: CPU LEDCadence (rate) Meaning

Steady Initializing

100 ms (on)/ 1s (off) Loading

10 ms (on)/ 10 ms (off) Boot flash update

300 ms (on)/ 300 ms (off) CPU standby

2-3

Page 10: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

Cadence (rate) Meaning

8 x (900 ms (on)/ 600 ms (off))/1 s (off) RAM test error

8 x (300 ms (on)/ 600 ms (off))/1 s (off) Checksum error

Chapter 2

2-4

Page 11: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

3.1 Connection

The NPRAE board is inserted in an interface position in the ACT shelf.

Figure 3.1: Connecting the NPRAE Board

If the connection is:

- by cable: connection to the main distribution frame is via a type 2 cable (see TY296PTSDIN cable - Hardware description),

3-1

Page 12: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

Note:the second T2 interface is distributed on the pairs corresponding to the first T0 interface of a BPRAboard.

- by coaxial cable: connection to the data transmission equipment is via 4 type 5 cables (seemodule TY5 9PTS DIN/BNC cable - Hardware description),

Caution:the NPRAE board uses the same 75 ohm cables as the PRA2 board, but the first link receptioncable (75 ohms) must be connected to position 18–20, instead of position 10–12 for the PRA2board.

- by patch panel (VH cabinet only): connection is directly performed using the patch panel:16-port 4-wire module (see Patch Panel - 16 ports module - 16 ports module).

3.2 Board Output Pins

View of the backpanel

A B C NOTES

1

2 L1_TXA_TIP L1_TXB_RING L1_TXA = E1 transmissionL1_RXA = E1 reception3 L1_RXA_TIP1 L1_TXA_TIP L1_RXB_RING1

4 L1_TXB_RING

5

6

7 GND

8 GND

9 GND 75 Ohm connections

10 L2_TXA_TIP L2_TXB_RING 120 Ohm connections

11 L2_RXA_TIP1 L2_TXA_TIP L2_RXB_RING1

12 L2_TXB_RING

13 AL1

14 L2_RXA_TIP1 AL2 L2_RXB_RING1

15 L2_TXA_TIP GND L2_TXB_RING

16 GND

17 A5V

18 L2_TXA_TIP L2_TXB_RING

19 L2_RXA_TIP1 L1_RXA_TIP1 L2_RXB_RING1

20 L1_RXB_RING1 ALCV

21

22 UART_RTS

23 GND

24 GND

Chapter 3

3-2

Page 13: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

View of the backpanel

A B C NOTES

25 GND

26 GND UART_TX

27 L2_RXA_TIP1

28 L2_RXB_RING1

29 UART_RX

30 GND GND

31 Strap GND Strap Used for industrial tests

32 GND

3-3

Page 14: Alcatel-Lucent OmniPCX Enterprise Communication …intraconsult-telecom.com/uploads/140/18/NPRAE.pdf · 1.1 Overview The NPRAE (New Primary Rate Access E1) board replaces the PRA2

Chapter 3