airair-cooled thermo-con air-cooled -cooled thermo-conthermo … · 2017. 5. 24. · auto-tuning,...
TRANSCRIPT
�0.01°C to 0.03°CType of circulating fluid: Water
Air-cooled Thermo-conAir-cooled Thermo-conAir-cooled Thermo-con
Series HEC
NPP-E05-8
�0.01°C to 0.03°CType of circulating fluid: Water
International standards: Plan to acquire , UL standards ( ) .International standards: Plan to acquire , UL standards ( ) .
Set temperaturerange:
Cooling capacity(with water):
Temperaturestability: 10°C to 60°C
230W
Set temperaturerange:
Cooling capacity(with water):
Temperaturestability: 10°C to 60°C
230W
Circulator Electronic Cooling / Heating Type
1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPANTel: 03-3502-2740 Fax: 03-3508-2480URL http://www.smcworld.com© 2005 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
1st printing JZ printing JZ 130KS Printed in Japan.D-KS
This catalog is printed on recycled paper with concern for the global environment.
Model
Communication
Control method
Cooling / Heating method
Exothermic method
Set temperature range
Temperature stability
Cooling capacity
Heating capacity
HEC002-A5A
RS-485
HEC002-A5B
RS-232C
Cooling / Heating automatic conversion PWM control
Electron cooling / heating element (Thermo-module)
Compulsory air-cooled
10.0 to 60.0°C
Within �0.01 to 0.03°C (when a load is stabilized) Note 1)
230 W (Water) Note 1)
600 W (Water) Note 1)
Water
Approx.1.2 l
Discharge pressure of 0.05 MPa at water flow of 2.4 l / min. (Both 50/60 Hz)
10 to 35°C (with no condensation)
Rc 1/4
Rc 1/4 (with plug): Part for maintenance purpose
Single phase, 100 to 240 V AC, 50/60 Hz, 8 A to 3 A
Flow switch: Output shut-out warning at reduced circulating fluid flow (0.7 l / min. or less) Note 2)
Width 210 x Height 393 x Depth 436 mm (excluding the portion sticking out)
Approx. 17.5 kg
Circulatingfluid
Ambient temperature / humidity
Port size
Power supply
Main features
Optional functions
Dimensions
Weight
Applicable fluid
Tank capacity
Pump capacity
Circulating fluid
General Specifications
Air-cooling feature enables cooling or heating temperature control even in locations where cooling water facilities are not provided.
This originally developed heat exchanger achieves low noisegeneration (55 dB) with a compact body.
A wide range of applicable voltages: 100 to 240 V AC
Air-cooling feature enables cooling or heating temperature control even in locations where cooling water facilities are not provided.
This originally developed heat exchanger achieves low noisegeneration (55 dB) with a compact body.
A wide range of applicable voltages: 100 to 240 V AC
Drain port forcirculating fluid
Note 1) Conditions at set temperature of 25°C, circulating flow rate of 3 l / min, ambient temperature of 25°C Note 2) Add "-F" to the end of the model number when the option (with a flow switch) that emits an output shut-out warning sign at reduced circulating fluid flow is attached. (HEC002-A5A-F / HEC002-A5B-F)
Auto-tuning, Sensor fine adjustment, Offset, Learning control, External tuning, Water-level reduction warning,
Upper / Lower temperature limit warning, Output shut-out warning
Thermo-conThermo-conThermo-con
Series HEC
NPP-E05-10
Circulator Electronic Cooling / Heating Type
�0.01°C to 0.03°CSet temperaturerange:
Cooling capacity(with water):
Temperaturestability: 10°C to 60°C
Type of circulating fluid:Water, Fluorinated chemicals
International standards: Plan to acquire , UL standards ( ) .
600W,1200W
�0.01°C to 0.03°CSet temperaturerange:
Cooling capacity(with water):
Temperaturestability: 10°C to 60°C
Type of circulating fluid:Water, Fluorinated chemicals
International standards: Plan to acquire , UL standards ( ) .
600W,1200W
Model
Communication
Control method
Cooling / Heating method
Exothermic method
Set temperature range
Temperature stability
Cooling capacity
Heating capacity
Flow rate
Temperature
Max. operating pressure
Circulating water
Cooling water
HEC006-W2A
RS-485
HEC006-W2B
RS-232C
HEC012-W2A
RS-485
HEC012-W2B
RS-232C
Cooling / Heating automatic conversion PWM control
Electron cooling / heating element (Thermo-module)
Water-cooled
10.0 to 60.0°C
�0.01 to 0.03°C (when a load is stabilized.)
10 to 35°C (with no condensation)
1 MPa
Rc 1/4 (with plug): Port for maintenance purpose
Auto-tuning, Sensor fine tuning, Offset, Learning control, External tuning, Water-level reduction warning, Upper / Lower temperature limit warning, Output shut-out warning
600 W (Water), 400 W (FluorinertTM FC-77) Note 1)
900 W (Water), 600 W (FluorinertTM FC-77) Note 1)
Water, Fluorinated chemicals (GALDEN® HT135, Fluorinert TM FC-77)
Approx. 3 l
1200 W (Water), 800 W (FluorinertTM FC-77) Note 2)
2200 W (Water), 1500 W (FluorinertTM FC-77) Note 2)
Water, Fluorinated chemicals (GALDEN® HT135, Fluorinert TM FC-77)
Approx. 5 l
8 l / min. or more 10 l / min. or more
Rc 3/8
Rc 3/8
Rc 3/4
Rc 1/2
Single phase, 200 to 220 V AC, 50/60 Hz, 5 A to 4 A Single phase, 200 to 220 V AC, 50/60 Hz, 10 A to 9 A
Width 240 x Height 390 x Depth 482 mm (excluding the portion sticking out)
Approx. 25 kg
Width 300 x Height 448 x Depth 550 mm (excluding the portion sticking out)
Approx. 40 kg
Discharge pressure 0.045 MPa (Both 50/60 Hz)
with water flow 10 l / min.
Discharge pressure 0.08 MPa (Both 50/60 Hz)
with FluorinertTM FC-77 flow 8 l / min.
Discharge pressure 0.03 MPa (50 Hz), 0.085 MPa (60 Hz)
with water flow 20 l / min.
Discharge pressure 0.13 MPa (50 Hz), 0.16 MPa (60 Hz)
with FluorinertTM FC-77 flow 15 l / min.
Port size
Power supply
Main features
Dimensions
Weight
General Specifications
Note 1) Conditions for circulating fluid with constant temperature of 25°C and flow rate of 8 l /min; cooling water temperature of 20°C and flow rate of 8 l /min; ambient temperature of 25°C. Note 2) Conditions for circulating fluid with constant temperature of 25°C and flow rate of 15 l /min; cooling water temperature of 20°C and flow rate of 10 l /min; ambient temperature of 25°C. GALDEN® is a registered trademark of Solvay Solexis, Inc. FluorinertTM is a trademark of 3M.
This originally developed heat exchanger achieves a large cooling capacity with a compact body.
Fluorinated chemicals (GALDEN ® HT135, FluorinertTM
FC-77) compatible with a standard model
This originally developed heat exchanger achieves a large cooling capacity with a compact body.
Fluorinated chemicals (GALDEN ® HT135, FluorinertTM
FC-77) compatible with a standard model
Drainage port forcirculating water
Applicable fluid
Tank capacity
Pump capacity
Circulatingfluid
Coolingwater
1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPANTel: 03-3502-2740 Fax: 03-3508-2480URL http://www.smcworld.com© 2005 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
1st printing JZ printing JZ 130KS Printed in Japan.D-KS