air master fume hood product catalog (2009)

44
telephone 231-798-1111 1 EH-HP High Performance Low Velocity Series Hood ___________________________ 2 Student Work Station ________________________________________________ 4 Eliminator 100 Series Standard Aerodynamic Hood ___________________________ 6 Eliminator 200 Series Double Faced 100 Series Hood _________________________ 8 Eliminator 300 Series Slim Line Hood ____________________________________ 10 Eliminator 400 Series Walk-In Hood _____________________________________ 12 Eliminator 500 Series ADA Hood (Barrier Free Design) ________________________ 14 Eliminator 600 Series Radio Isotope Hood ________________________________ 16 Eliminator 700 Series Perchloric Acid Hood _______________________________ 18 Eliminator 800 Series Flat Front Hood ___________________________________ 20 Eliminator 900 Series Demonstration Hood ________________________________ 22 Paint Spray Booth__________________________________________________ 24 Self-Contained and Portable Hoods _____________________________________ 26 Canopy Hoods ____________________________________________________ 27 Air Monitor Alarms _________________________________________________ 28 Ceiling Enclosures and Finished Backs___________________________________ 29 Plumbing Accessories_______________________________________________ 30 Electrical Accessories and Specifications_________________________________ 31 Sash Options _____________________________________________________ 32 Base Cabinets ____________________________________________________ 33 Epoxy Resin and Stainless Steel Surfaces _________________________________ 34 Air Chamber Option ________________________________________________ 35 QUICK SHIP Fume Hoods, Epoxy Tops and Base Cabinets__________________ 36 QUICK SHIP Stainless Steel Products _______________________________ 37 Stainless Steel Countertops___________________________________________ 38 Blowers, Lattice Assemblies and Peg Boards ______________________________ 39 Knock Down Hoods _________________________________________________ 40 Fume Hood General Design Requirements ________________________________ 41 Glossary ________________________________________________________ 44 Color Chart ___________________________________________ inside back cover Ordering Guide ______________________________________________ back cover Contents

Upload: anthony-stellatos

Post on 22-Mar-2016

324 views

Category:

Documents


7 download

DESCRIPTION

Air Master System is a U.S. manfacturer or laboratory fume hoods. Located in Michigan, they produce a variety of bench top, walk-in, demonstration, perchloric and radio isotope fume hoods.

TRANSCRIPT

telephone 231-798-1111 1

EH-HP High Performance Low Velocity Series Hood ___________________________ 2

Student Work Station ________________________________________________ 4

Eliminator 100 Series Standard Aerodynamic Hood ___________________________ 6

Eliminator 200 Series Double Faced 100 Series Hood _________________________ 8

Eliminator 300 Series Slim Line Hood ____________________________________ 10

Eliminator 400 Series Walk-In Hood _____________________________________ 12

Eliminator 500 Series ADA Hood (Barrier Free Design) ________________________ 14

Eliminator 600 Series Radio Isotope Hood ________________________________ 16

Eliminator 700 Series Perchloric Acid Hood _______________________________ 18

Eliminator 800 Series Flat Front Hood ___________________________________ 20

Eliminator 900 Series Demonstration Hood ________________________________ 22

Paint Spray Booth __________________________________________________ 24

Self-Contained and Portable Hoods _____________________________________ 26

Canopy Hoods ____________________________________________________ 27

Air Monitor Alarms _________________________________________________ 28

Ceiling Enclosures and Finished Backs ___________________________________ 29

Plumbing Accessories _______________________________________________ 30

Electrical Accessories and Specifications _________________________________ 31

Sash Options _____________________________________________________ 32

Base Cabinets ____________________________________________________ 33

Epoxy Resin and Stainless Steel Surfaces _________________________________ 34

Air Chamber Option ________________________________________________ 35

QUICK SHIP Fume Hoods, Epoxy Tops and Base Cabinets __________________ 36

QUICK SHIP Stainless Steel Products _______________________________ 37

Stainless Steel Countertops ___________________________________________ 38

Blowers, Lattice Assemblies and Peg Boards ______________________________ 39

Knock Down Hoods _________________________________________________ 40

Fume Hood General Design Requirements ________________________________ 41

Glossary ________________________________________________________ 44

Color Chart ___________________________________________ inside back cover

Ordering Guide ______________________________________________ back cover

Contents

www.airmastersystems.com2

U.L. 1805Classified

60 FPM • FITS THROUGH STANDARD DOOR • 30” COUNTERTOPThe HP Eliminator is THE hood for remodeling, new construction or retrofitting.

The Eliminator HP SERIES: High Performance/Energy Efficient

A Green AlternativeThe Eliminator HP hood is designed to

operate economically while creating a safe work environment without compromising containment. Buy operating at 60 FPM, air flow across the sash opening results in a 40% savings in fume hood operation costs.

The HP model comes standard with all the same features as other Eliminator models, along with some additional innovations to set this hood apart from its competitors. Features of the HP Series include:• 40-60%energysavings,accomplished

without compromising performance or safety.

• High-efficiencyL.E.D.lightingwithlowmaintenance costs.

• Standard30"deepworksurfaceforzerowork space loss.The HP hood was designed to do all this

andstillfitonastandard-depthcountertopand cabinet. This means no disassembly and reassembly during the installation process. TheHPhoodfitsthroughastandarddooropening, making this hood the choice for thatretrofitjob.

EH-HPStandard Features

• PowderCoatFinish

• FullFrameConstruction

• ShaftDriveSash

• U.L.ListedPolyResinLiner

• LEDLights

• FlushMountAirFoil

• KnockDownCapability

• InteriorAccesstoLight

• Full-LengthFingerLift

• SashSweep

• AirflowMonitor/Alarm

• SashAlarm

KNOCK DOWN—

SEE PAGE 40

telephone 231-798-1111 3

APPLICATIONS: Higher Education; Industrial; Private Research

The Eliminator HP SERIES: High Performance/Energy Efficient

EH-HPOptional Accessories

ITEM AMS PT# PAGE #

CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

EpoxyTops ET 34

Alarms ALARM 28

BaseCabinets BC 33

Blowers BL 39

Pre-Plumbing PREP

Pre-Wiring PREW

ITEM AMS PT# PAGE #

SashStops SASHSTOP 32

Chain&SprocketDrive CHNSPK Call

StainlessSteelSash SSSASH 32

StainlessSteelAirfoil SSAF

PushButtonSash PUSHBUTTON 32

CombinationSash H&V 32

LatticeAssembly LATTICE 39

AutoSashReturn 32

Part NumberSuperstructure Worktop Hood Opening CFM

@ 28”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-HP-48 48” 56” 33-1/4” 48” 1-1/4” 30” 38” 28” 469 313 .25 BL-HP-48 200

EH-HP-60 60” 56” 33-1/4” 60” 1-1/4” 30” 50” 28” 619 413 .34 BL-HP-60 225

EH-HP-72 72” 56” 33-1/4” 72” 1-1/4” 30” 62” 28” 769 513 .34 BL-HP-72 270

EH-HP-96 96” 56” 33-1/4” 96” 1-1/4” 30” 86” 28” 1069 713 .34 BL-HP-96 300

*Height of open sash; CFM calculated at 60 FPM

EH-HP-48 EH-HP-60

EH-HP-72 EH-HP-96

www.airmastersystems.com4

U.L. 1805Classified

The Eliminator SWS SERIES: Student Work Station

Viewing Everything

TheStudentWorkStationisasafe,highly-visibleworkingenvironmentwithfull360ºviewing.Thishoodhasmany of the standard features that are incorporatedintoeveryAMShood.Inaddition, this hood has the flexibility necessary to allow you to easily design yourworkspacebyputtinghoodsback-to-back,side-by-sideorinjustaboutanyotherconfigurationneeded.Theunique design of this product allows for the plumbing and electrical devices to be easily accessed for installation and maintenance personnel.

Student Work StationStandard Features

• Two-tube,rapidstart,ULlistedfluorescentlightfixturewithsound rated ballast installed on exterior of roof. Provide safety glass panel sealed to the hood roof.

• Fullviewlaminatedsafetyglass.

• Endviewpanels.

• Hoodsmeetorexceed thespecificationssetby ASHRAE110-1995and SAMAstandardLF-10.

• Sashcables:steel,coated, 1/8”diameter.

• Sashcablepulleyassemblyis 2”diameter,ballbearingtype,with cable retaining device.

APPLICATIONS: Higher Education; Industrial; Private Research

telephone 231-798-1111 5

The Eliminator SWS SERIES: Student Work Station

Student Work StationOptional Accessories

ITEM AMS PT# PAGE #

PlumbingAccessories 30

BaseCabinets 33

Electrical 31

Part NumberSuperstructure Worktop Hood Opening CFM

@ 100LFM SP at Hood** Duct SizeW H D W H D W H

EH-SWS-48 48" 60" 32-3/8" 48" 1-1/4" 29" 45-3/8" 29" 770 .25” 4” x 24”

EH-DWS-48 48" 60" 64-3/4" 48" 1-1/4" 58" 45-3/8" 29" 770 .25” 2 – 4” x 24”

EH-SWS-60 60" 60" 32-3/8" 60" 1-1/4" 29" 57-3/8" 29" 1000 .33” 4” x 30”

EH-DWS-60 60" 60" 64-3/4" 60" 1-1/4" 58" 57-3/8" 29" 1000 .33” 2 – 4” x 30”

EH-SWS-72 72" 60" 32-3/8" 72" 1-1/4" 29" 69-3/8" 29" 1250 .5” 4” x 36”

EH-DWS-72 72" 60" 64-3/4" 72" 1-1/4" 58" 69-3/8" 29" 1250 .5” 2 – 4” x 36”

SWS = Single Sided Work StationDWS = Double Sided Work Station (order two single sided hoods and face them back to back)

www.airmastersystems.com6

Minimized Turbulence, Increased Performance

TheEH100seriesairfoil-type

fume hood features a 45-degree angle

around the fascia and a flush-mount

radiused airfoil across the bottom,

whichresultsinminimizedturbulence

and increased performance.

Liketheexteriorofthehood,

theairfoilismadefromchemical-

resistant,powder-coated,16-gauge

cold-rolledsteel.Astainlesssteel

airfoil is available as an option.

Postsare5”(127mm)wide.

Fivestandardsizesofferdesign

flexibility,orwe’llcustomizetoyour

specificneeds.

APPLICATIONS: K-12; Higher Education; Industrial; Private Research

U.L. 1805 Classified

The Eliminator 100 SERIES: Airfoil Fume Hood

EH-100Standard Features

• PowderCoatFinish

• FullFrameConstruction

• ShaftDriveSash

• U.L.ListedPolyResinLiner

• T-8FluorescentLightwithbulbs

• FlushMountAirFoil

• KnockDownCapability

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

• 10”RoundS/SDuctCollar

KNOCK DOWN—

SEE PAGE 40

telephone 231-798-1111 7

The Eliminator 100 SERIES

Part NumberSuperstructure Worktop Hood Opening CFM

@ 29”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-111-36 36” 56” 33-1/4” 36” 1-1/4” 30” 26” 29” 567 354 .25 BL-100-36 190

EH-111-48 48” 56” 33-1/4” 48” 1-1/4” 30” 38” 29” 833 521 .25 BL-100-48 200

EH-111-60 60” 56” 33-1/4” 60” 1-1/4” 30” 50” 29” 1100 688 .34 BL-100-60 225

EH-111-72 72” 56” 33-1/4” 72” 1-1/4” 30” 62” 29” 1367 854 .34 BL-100-72 270

EH-111-96 96” 56” 33-1/4” 96” 1-1/4” 30” 86” 29” 1900 1188 .40 BL-100-96 300

EH-100Optional Accessories

ITEM AMS PT# PAGE #

CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

EpoxyTops ET 34

Alarms ALARM 28

BaseCabinets BC 33

Blowers BL 39

Pre-Plumbing PREP

Pre-Wiring PREW

ITEM AMS PT# PAGE #

SashStops SASHSTOP 32

Chain&SprocketDrive CHNSPK Call

StainlessSteelSash SSSASH 32

StainlessSteelAirfoil SSAF

PushButtonSash PUSHBUTTON 32

CombinationSash H&V 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

EH-111-36 EH-111-48 EH-111-60

EH-111-72 EH-111-96

*Height of open sash; CFM calculated at 100 FPM

www.airmastersystems.com8

APPLICATIONS: K-12 classrooms and other demonstration settings

The Eliminator 200 SERIES: Double-Faced 100 Series

Dual Access

TheEliminator200seriesprovidesthesame aerodynamic design features as the EH-100AirfoilHoodseries,withentrancefrom two sides. This makes it ideal for use in classroom or prep room settings or whenever demonstration of experiments is desired.

A45-degreeanglearoundthefasciaandaflush-mountradiusedairfoilacrossthebottomprovideminimizedturbulenceandincreased performance.

TheEH-200featuresstandard5”(127mm)poststoallowforelectricalandremotecontrol plumbing services on both sides, andthesecanbeconfiguredtoyourexactspecifications.

Fivestandardsizesandanarrayofoptionsmake this one of the most flexible fume hoods available anywhere.

EH-200Standard Features

• PowderCoatFinish

• FullFrameConstruction

• U.L.ListedPolyResinLiner

• T-8FluorescentLightwithbulbs

• FlushMountAirfoil

• KnockDownCapability

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

U.L. 1805Classified

telephone 231-798-1111 9

The Eliminator 200 SERIES: Double-Faced 100 Series

Part NumberSuperstructure Worktop Hood Opening CFM

@ 29”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-211-36 36” 56” 35-1/2” 36” 1-1/4” 29” 26” 29” 567 354 .25 BL-100-36 190

EH-211-48 48” 56” 35-1/2” 48” 1-1/4” 29” 38” 29” 833 521 .33 BL-100-48 200

EH-211-60 60” 56” 35-1/2” 60” 1-1/4” 29” 50” 29” 1100 688 .34 BL-100-60 225

EH-211-72 72” 56” 35-1/2” 72” 1-1/4” 29” 62” 29” 1367 854 .34 BL-100-72 270

EH-211-96 96” 56” 35-1/2” 96” 1-1/4” 29” 86” 29” 1900 1188 .40 BL-100-96 300

EH-200Optional Accessories

ITEM AMS PT# PAGE #CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

EpoxyTops ET 34

Alarms ALARM 28

BaseCabinets BC 33

Blowers BL 39

Pre-Plumbing PREP

Pre-Wiring PREW

ITEM AMS PT# PAGE #SashStops SASHSTOP 32

StainlessSteelSash SSSASH 32

StainlessSteelAirfoil SSAF

PushButtonSash PUSHBUTTON 32

CombinationSash H&V 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

SashInterlock 32

*Height of open sash; CFM calculated at 100 FPM with one sash open

EH-211-36 EH-211-48 EH-211-60

EH-211-72 EH-211-96

www.airmastersystems.com10

Expanded Workspace

TheEliminator300seriesisathin-wall fume hood with slimmer front posts to expand the workspace. Posts are 2-1/2”(64mm)wide.

Because the slimmer posts remove the option for wiring and plumbing in the posts, plumbing services must be deck mounted”onepoxytop,andelectricalservices must be mounted on the face ofthecabinet.(Seecabinetoptionsonpage33.)

Fivestandardsizesandanarrayof options make this one of the most flexible fume hoods available anywhere.

APPLICATIONS: K-Middle School

The Eliminator 300 SERIES: Thin Wall

EH-300Standard Features

• PowderCoatFinish

• FullFrameConstruction

• ShaftDriveSash

• U.L.ListedPolyResinLiner

• T-8FluorescentLightwithbulbs

• KnockDownCapability

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

KNOCK DOWN—

SEE PAGE 40

U.L. 1805Classified

telephone 231-798-1111 11

The Eliminator 300 SERIES: Thin Wall

Part NumberSuperstructure Worktop Hood Opening CFM

@ 28”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-311-36 36” 56” 29-1/2” 36” 1-1/4” 30” 26” 28” 646 431 .25 BL-300-36 190

EH-311-48 48” 56” 29-1/2” 48” 1-1/4” 30” 43” 28” 896 597 .25 BL-300-48 175

EH-311-60 60” 56” 29-1/2” 60” 1-1/4” 30” 55” 28” 1146 764 .39 BL-300-60 200

EH-311-72 72” 56” 29-1/2” 72” 1-1/4” 30” 67” 28” 1417 944 .37 BL-300-72 250

EH-311-96 96” 56” 29-1/2” 96” 1-1/4” 30” 91” 28” 1896 1264 .43 BL-300-96 275

EH-300Optional Accessories

ITEM AMS PT# PAGE #

CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

EpoxyTops ET 34

Alarms ALARM 28

BaseCabinets BC 33

Blowers BL 39

ITEM AMS PT# PAGE #

SashStops SASHSTOP 32

Chain&SprocketDrive CHNSPK Call

StainlessSteelSash SSSASH 32

CombinationSash H&V 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

EH-311-36 EH-311-48 EH-311-60

EH-311-72 EH-311-96

*Height of open sash; CFM calculated at 100 FPM

www.airmastersystems.com12

For Those Tall Experiments

The Eliminator 400 series, with a double-hungsashconfigurationand72-inchhighopening,isdesignedtoaccommodatealarge-apparatusapplication,upto85”inheight.Postsare5”(127mm)wide.

AndwiththeAMSexclusiveknock-downability,evenahoodthisbigisabreezetoinstall,maintain,repair and move.

APPLICATIONS: University, Research, Private Industry

The Eliminator 400 SERIES: Walk-In Hood

EH-400Standard Features

• PowderCoatFinish

• FullFrameConstruction

• ShaftDriveSash

• U.L.ListedPolyResinLiner

• T-8FluorescentLightwithbulbs

• FlushMountAirfoil

• KnockDownCapability

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

KNOCK DOWN—

SEE PAGE 40

U.L. 1805Classified

telephone 231-798-1111 13

The Eliminator 400 SERIES: Walk-In Hood

EH-400Optional Accessories

ITEM AMS PT# PAGE #

CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

Alarms ALARM 28

Blowers BL 39

Pre-Plumbing PREP

Pre-Wiring PREW

SashStops SASHSTOP 32

ITEM AMS PT# PAGE #

Chain&SprocketDrive CHNSPK Call

StainlessSteelSash SSSASH 32

PushButtonSash PUSHBUTTON 32

CombinationSash H&V 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

EH-411-72 EH-411-96

Part NumberSuperstructure Hood Opening

CFM @ 36”* CFM @ 72”* SP Blower Model # Approx. Shipping WeightW H D W H

EH-411-48 48” 93” 35” 38” 72” 990 1979 .25 BL-400-48 200

EH-411-60 60” 93” 35” 50” 72” 1306 2613 .34 BL-400-60 225

EH-411-72 72” 93” 35” 62” 72” 1623 3246 .34 BL-400-72 270

EH-411-96 96” 93” 35” 86” 72” 2256 4513 .34 BL-400-96 300

EH-411-48 EH-411-60

*Height of open sash; CFM calculated at 100 FPM

www.airmastersystems.com14

Meets ADA Dimensional Guidelines

TheEliminator500seriesisanairfoil-typefumehooddesignedtomeetADAdimensionalguidelines.

A45-degreeanglearoundthefasciaandaflush-mountradiusedairfoilacrossthebottomresultinminimizedturbulenceandincreasedperformance.

TheADAhood’sairfoilflipsbackoutofthewayforcleanup.Undertheairfoilisacontainment trough to capture accidental spills that may flow over the dished worksurface. The trough assembly is fabricatedfromchemical-resistant16-gaugecold-rolledsteel.

AcombinationverticalandhorizontalsashisstandardontheEH-500.

ADAkneespace-configured”basecabinets,picturedatright,areavailable.Seepage33for cabinet options.See

page 33 for cabinet

options

APPLICATIONS: K-12; University, Private Industry

The Eliminator 500 SERIES: ADA Design

EH-500Standard Features

• PowderCoatFinish

• FullFrameConstruction

• ShaftDriveSash

• U.L.ListedPolyResinLiner

• T-8FluorescentLightwithbulbs

• FlushMountAirfoil

• KnockDownCapability

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

• PaintedSteelTroughAssembly

• AirflowAlarm

• SashStop

• CombinationSash

• 1/4TurnBallValves

KNOCK DOWN—

SEE PAGE 40

U.L. 1805Classified

telephone 231-798-1111 15

The Eliminator 500 SERIES: ADA Design

EH-500Optional Accessories

ITEM AMS PT# PAGE #

CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

EpoxyTops ET 34

Alarms ALARM 28

BaseCabinets BC 33

RollOutBase ROB 33

Blowers BL 39

Pre-Plumbing PREP

ITEM AMS PT# PAGE #

Pre-Wiring PREW

Chain&SprocketDrive CHNSPK Call

StainlessSteelSash SSSASH 32

StainlessSteelAirfoil SSAF

PushButtonSash PUSHBUTTON 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

BaseFramesandCabinets 33

Part NumberSuperstructure Worktop Hood Opening CFM

@ 30”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-521-48 48” 56” 33-1/4” 48” 1-1/4” 30” 38” 29” 833 521 .25 BL-500-48 200

EH-521-60 60” 56” 33-1/4” 60” 1-1/4” 30” 50” 29” 1100 688 .34 BL-500-60 225

EH-521-72 72” 56” 33-1/4” 72” 1-1/4” 30” 62” 29” 1367 854 .34 BL-500-72 270

EH-521-48 EH-521-60 EH-521-72

Base frames and cabinets sold separately. See page 33.

*Height of open sash; CFM calculated at 100 FPM

www.airmastersystems.com16

For Safe Handling of Radiochemicals

TheEliminator600RadioIsotopeHoodisspecificallyengineeredandbuilttohandleapplications involving radiochemicals.

Ithasthesameaerodynamicdesignasthe standard airfoil hood, with the added featureofradiusconstructiononaone-piecestainless-steellinerandcountertopto prevent absorption of radioactive and corrosive chemicals.

The interior of the hood and integral countertoparefabricatedof304stainlesssteel, buffed and polished to a smooth #4 finish.Thisreducesthechanceofchemicalbuildupandsimplifiesdecontamination.

Theflush-mountradiusedairfoilisalsotype304stainlesssteel,asisthestandardverticalrisingsash.Acombinationsashisavailable as an option.

Fiveavailablesizesandmanyoptionalaccessories meet all your design needs and the end user’s application requirements.

APPLICATIONS: University, Private Industry

The Eliminator 600 SERIES: Radio Isotope Hood

EH-600Standard Features

• PowderCoatFinish

• FullFrameConstruction

• ShaftDriveSash

• T-8FluorescentLightwithbulbs

• FlushMountAirfoil

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

• 304StainlessSteelOne-PieceIntegralWorkSurfaceandLiner

• StainlessSteelSash

• StainlessSteelAirfoil

U.L. 1805Classified

telephone 231-798-1111 17

The Eliminator 600 SERIES: Radio Isotope Hood

Part NumberSuperstructure Integral Worktop Hood Opening CFM

@ 29”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-613-36 36” 56” 33-1/4” 36” 1-1/4” 30” 26” 29” 567 354 .25 BL-100-36 190

EH-613-48 48” 56” 33-1/4” 48” 1-1/4” 30” 38” 29” 833 521 .25 BL-100-48 200

EH-613-60 60” 56” 33-1/4” 60” 1-1/4” 30” 50” 29” 1100 688 .34 BL-100-60 225

EH-613-72 72” 56” 33-1/4” 72” 1-1/4” 30” 62” 29” 1367 854 .34 BL-100-72 270

EH-613-96 96” 56” 33-1/4” 96” 1-1/4” 30” 86” 29” 1900 1188 .40 BL-100-96 300

EH-600Optional Accessories

ITEM AMS PT# PAGE #

CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

Alarms ALARM 28

BaseCabinets BC 33

Blowers BL 39

Pre-Plumbing PREP

Pre-Wiring PREW

ITEM AMS PT# PAGE #

SashStops SASHSTOP 32

Chain&SprocketDrive CHNSPK Call

PushButtonSash PUSHBUTTON 32

CombinationSash H&V 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

EH-613-36 EH-613-48 EH-613-60

EH-613-72 EH-613-96

*Height of open sash; CFM calculated at 100 FPM

www.airmastersystems.com18

Safe Handling of Perchloric Acid

TheEliminator700PerchloricAcidHoodhas the same aerodynamic design as the 100series,witha45-degreeanglearoundthefasciaandaflush-mountradiusedairfoilacrossthebottomtominimizeturbulenceandprovide increased performance.

Thishard-workinghoodalsofeaturesabuilt-introughtocapturerunoffinwashdownprocedureswhereperchloricacidisinuse.Inaddition, there is a manual washdown feature for the areas behind the baffles as well as the duct-collarareas.

Theinteriorisfabricatedwithtype316stainlesssteel,integrallyweldedtoa316stainless-steelworksurface,thenbuffedandpolishedtoa#4finish.Thetopis1-1/4’witha1/4-inchdishtoretainspills.Theairfoilandsasharealsomadeof316stainlesssteel.

TheEH-700isbuilttoughtowithstandthedaily use of perchloric acid, while keeping the workplace safe.

APPLICATIONS: University, Private Industry

The Eliminator 700 SERIES: Perchloric Acid Hood

EH-700Standard Features

• PowderCoatFinish

• FullFrameConstruction

• ShaftDriveSash

• T-8FluorescentLightwithbulbs

• FlushMountAirfoil

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

• 316StainlessSteelOne-PieceIntegralWorkSurfaceandLiner

• Built-InTrough

• ManualWashDown

• StainlessSteelSash

• StainlessSteelAirfoil

U.L. 1805Classified

telephone 231-798-1111 19

The Eliminator 700 SERIES: Perchloric Acid Hood

Part NumberSuperstructure Integral Worktop Hood Opening CFM

@ 29”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-716-36 36” 56” 33-1/4” 36” 1-1/4” 30” 26” 29” 567 354 .25 BL-100-36 190

EH-716-48 48” 56” 33-1/4” 48” 1-1/4” 30” 38” 29” 833 521 .33 BL-100-48 200

EH-716-60 60” 56” 33-1/4” 60” 1-1/4” 30” 50” 29” 1100 688 .34 BL-100-60 225

EH-716-72 72” 56” 33-1/4” 72” 1-1/4” 30” 62” 29” 1367 854 .34 BL-100-72 270

EH-716-96 96” 56” 33-1/4” 96” 1-1/4” 30” 86” 29” 1900 1188 .40 BL-100-96 300

EH-700Optional Accessories

ITEM AMS PT# PAGE #

CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

Alarms ALARM 28

BaseCabinets BC 33

Blowers BL 39

Pre-Plumbing PREP

Pre-Wiring PREW

ITEM AMS PT# PAGE #

SashStops SASHSTOP 32

Chain&SprocketDrive CHNSPK Call

PushButtonSash PUSHBUTTON 32

CombinationSash H&V 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

EH-716-36 EH-716-48 EH-716-60

EH-716-72 EH-716-96

*Height of open sash; CFM calculated at 100 FPM

www.airmastersystems.com20

Economical School Hood

AbasicfumehoodforK-12educational applications, the EH 800seriesissimilarindesignandconstructiontotheEH-300(ThinWall)hood,butwith5”(127mm)poststoprovideplumbingandelectricalfixtureson the face of the hood. This hood has many of the same features found in otherAMShoods,butitiseconomicallypriced for secondary school budgets.

APPLICATIONS: K-12

The Eliminator 800 SERIES: Flat Front

EH-800Standard Features

• PowderCoatFinish

• FullFrameConstruction

• ShaftDriveSash

• U.L.ListedPolyResinLiner

• T-8FluorescentLightwithbulbs

• KnockDownCapability

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

• 10"RoundDuct

KNOCK DOWN—

SEE PAGE 40

U.L. 1805Classified

telephone 231-798-1111 21

The Eliminator 800 SERIES: Flat Front

Part NumberSuperstructure Worktop Hood Opening CFM

@ 29”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-811-36 36” 56” 29-1/2” 36” 1-1/4” 30” 26” 29” 567 354 .25 BL-100-36 190

EH-811-48 48” 56” 29-1/2” 48” 1-1/4” 30” 38” 29” 833 521 .33 BL-100-48 200

EH-811-60 60” 56” 29-1/2” 60” 1-1/4” 30” 50” 29” 1100 688 .34 BL-100-60 225

EH-811-72 72” 56” 29-1/2” 72” 1-1/4” 30” 62” 29” 1367 854 .34 BL-100-72 270

EH-811-96 96” 56” 29-1/2” 96” 1-1/4” 30” 86” 29” 1900 1188 .40 BL-100-96 300

EH-800Optional Accessories

ITEM AMS PT# PAGE #

CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

EpoxyTops ET 34

Alarms ALARM 28

BaseCabinets BC 33

Blowers BL 39

Pre-Plumbing PREP

Pre-Wiring PREW

ITEM AMS PT# PAGE #

SashStops SASHSTOP 32

Chain&SprocketDrive CHNSPK Call

StainlessSteelSash SSSASH 32

PushButtonSash PUSHBUTTON 32

CombinationSash H&V 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

EH-811-36 EH-811-48 EH-811-60

EH-811-72 EH-811-96

*Height of open sash; CFM calculated at 100 FPM

www.airmastersystems.com22

Three Windows for Optimum Viewing

TheEH-900seriesisaneducationalviewing fume hood with one slimmed down(2”or51mm)frontpostandonestandard(5”or127mm)posttoallow for more workspace and electrical services. Plumbing service must be deck mounted.

TheEH-900isavailableineitherright-handorleft-handorientation.Thishoodfeaturesatwo-sashconfigurationandathird(end)viewingwindow, making it ideal for use in high schools or any environment where demonstration of experiments is desired. The end window may beeliminatedforthrough-wallinstallations.

(Left-handshown)

APPLICATIONS: K-12

The Eliminator 900 SERIES: Demonstration Hood

EH-900Standard Features

• PowderCoatFinish

• FullFrameConstruction

• U.L.ListedPolyResinLiner

• T-8FluorescentLightwithbulbs

• KnockDownCapability

• InteriorAccesstoLight

• Full-LengthFingerLift

• LouveredFrontforBy-Pass

• 10"RoundDuct

U.L. 1805Classified

telephone 231-798-1111 23

The Eliminator 900 SERIES: Demonstration Hood

EH-900Optional Accessories

ITEM AMS PT# PAGE #CeilingEnclosures CE 29

PlumbingAccessories 30

ElectricalAccessories 31

EpoxyTops ET 34

Alarms ALARM 28

BaseCabinets BC 33

Blowers BL 39

Pre-Plumbing PREP

Pre-Wiring PREW

ITEM AMS PT# PAGE #SashStops SASHSTOP 32

StainlessSteelSash SSSASH 32

PushButtonSash PUSHBUTTON 32

CombinationSash H&V 32

AutomaticSashReturn AUTORETURN 32

LatticeAssembly LATTICE 39

LEDLights LED

SashInterlock 32

Part NumberSuperstructure Worktop Hood Opening CFM

@ 26.5”*CFM

@ 18”* SPBlowerModel #

ShippingWeightW H D W H D W H

EH-911-60 60” 48” 30” 60” 1-1/4” 32” 53” 26.5”** 1030 722 .75 BL-900-60 185

Please specify Left or Right (Left shown) *Height of open sash; CFM calculated at 100 FPM with one sash open**Each side

EH-911-60LEH-911-60R

www.airmastersystems.com24

The Eliminator Paint (Spray) Booth

TheAMSPaintBoothisfabricatedof18-gauge steel with a corrosion resistant, powder coat baked epoxy finish. The upper booth enclosure includes a standard vapor-proof light as well as two filters set in an easy-to-change flange bracket system. The globed interior light is mounted and wired toacommonjunctionbox.AswithallAMSproducts,thelightfixtureisshippedwithbulbs, standard.

The optional blower motor operates at anRPMdesignedtoprovide100LFMandapproximately3⁄4”ofstaticpressure.Iftheblower is ordered, it will be mounted on top andwiredtothecommonjunctionbox.Thetransition piece from the booth to blower will be provided and connected. Both the light and theblowercanbepre-wiredtoswitchesinthefront post area of the booth when required.

Sold separatelyPart No. TT12CR

Dimensions:Paintboothsareavailableinwidthsof24”,30”,36”,48”and60” Allare48”Hx24”D.Specialsizesavailableuponrequest.

telephone 231-798-1111 25

Part Number Description CFM @ 100 FPM

AMS-24-PB 24” Paint (Spray) Booth 472

AMS-30-PB 30” Paint (Spray) Booth 613

AMS-36-PB 36” Paint (Spray) Booth 755

AMS-48-PB 48” Paint (Spray) Booth 1040

AMS-60-PB 60” Paint (Spray) Booth 1322

Paint (Spray) Booth

Paint (Spray) Booth with Blower

The Eliminator Paint (Spray) Booth

Explosion-Proof options

NOTE: Explosion-proof (X-P) switches must mount on the exterior of booth or be shipped loose for remote operation.

Paint BoothOptional Accessories

ITEM AMS PT# PAGE #LightSwitch LTSW 31

BlowerSwitch BLSW 31

StainlessSteelTop 34

ITEM AMS PT# PAGE #GalvanizedTop Call

Pre-WireService PREWIRE

AMS-30-PB AMS-48-PB

AMS-24-PB AMS-36-PB

Part Number Description CFM @ 100 FPM

AMS-24-XPB 24” Booth w/X-P Light 472

AMS-30-XPB 30” Booth w/X-P Light 613

AMS-36-XPB 36” Booth w/X-P Light 755

AMS-48-XPB 48” Booth w/X-P Light 1040

AMS-60-XPB 60” Booth w/X-P Light 1322

Part Number Description CFM @ 100 FPM

AMS-24-PBW 24” Booth and Blower 472

AMS-30-PBW 30” Booth and Blower 613

AMS-36-PBW 36” Booth and Blower 755

AMS-48-PBW 48” Booth and Blower 1040

AMS-60-PBW 60” Booth and Blower 1322

Part Number Description CFM @ 100 FPM

AMS-24-XPBW 24” Booth w/X-P Light and Blower 472

AMS-30-XPBW 30” Booth w/X-P Light and Blower 613

AMS-36-XPBW 36” Booth w/X-P Light and Blower 755

AMS-48-XPBW 48” Booth w/X-P Light and Blower 1040

AMS-60-XPBW 60” Booth w/X-P Light and Blower 1322

www.airmastersystems.com26

Optional Accessories

• 208,230or277VoltMotor

• Pre-filterTypesandEfficiencies

• PTEFandGelSealFilters

• ULPAUpgrades

• 1”EpoxyTop

• MobileCartw/LockingCasters

• PhotohelicGauge

• StainlessSteelConstruction

• Totally-ClosedFront

Standard Features

• PaintedSteelContruction

• Energy-SavingLEDLightFixture

• CombinationLight/Blower Switch

• GFIDuplexOutlet

• Pre-wired

• 8’PowerCord

• MagnahelicGauge

TheAMSself-containedhoodisacompletelyself-containedunit.Thebackward-curved120voltblowerhasavariablespeedcontroltomaximizeefficiencyandminimizemotornoise.The53mm99.99%efficientHEPAfilterisreplaceablefromthetopoftheunit.Italsocontainsaone-inch30%pre-filterthatisreplaceablefromtheinterioroftheunit.Thissitsatopafully-weldedtubechamberwithplexiglas windows for viewing from all four sides. The front hasafold-updoortoallowforloadingandunloadingofapparatus and experiments.

AMS Self-Contained HoodAPPLICATIONS: K-12, University, Private Industry

Model numbers: AMS-36-SC hoodonlyAMS-36-SCT hoodwithepoxytopAMS-36-SCTC hoodwithtopandcartForstainlesssteelconstructionusetheprefixSS

AMS Portable HoodThisportablehoodhasthesameconstructionfeaturesastheself-

containedunit,butmustbeconnectedtoanHVACsystem.

Standard Features

• PaintedSteelContruction

• Energy-SavingLEDLightFixture

• CombinationLight/Blower Switch

• GFIDuplexOutlet

• Pre-wired

• 8’PowerCord

Model numbers: AMS-36-PH hoodonlyAMS-36-PHT hoodwithepoxytopAMS-36-PHTC hoodwithtopandcartForstainlesssteelconstructionusetheprefixSS

telephone 231-798-1111 27

AMScanopyhoodsaredesignedtocollectandexhaust

heat, steam and odors when mounted above hot plates,

water baths or portable equipment. They are available in

three different models as pictured here and in six standard

widths:24”,30”,36”,48”,60”,and72”.Customsizes

are also available.

Standardcanopyhoodsareavailablein18-gaugecold

rolledsteel,finishedwithacidwashandpowdercoatepoxy

paint.(Seeinsidebackcoverforavailablestandardcolors.)

Stainlesscanopyhoodsarefabricatedof18-gauge304

stainlesssteelwitha#4smoothgrainfinish

Two stainless steel threaded rods come with FS and SE

models;fouraresuppliedwithILmodels.

To order canopy hoods:

CH-FS forflatbackandflatsides

CH-IL forcenterstyle

CH-SE forflatbackandslopedsides

For stainless steel option, add -SS”

For example:

CH-FS-4824 isapaintedsteel,48”wide,24”deep

canopy hood with flat back and flat sides.

CH-IL-6030-SS isa60”wide,30”deepislandcanopywith

stainless steel construction.

Canopy Hoods

www.airmastersystems.com28

AFA 1000/1Mk3

Fume Hood Airflow MonitorSpecifications

Part #AMS-AL1D

Display range 0-999 fpm (0-5.0 m/s)Alarm range 0-999 fpm (0-5.0 m/s)Field set-up 2-point velocity calibration ( with on-screen instructions )Accuracy Sensor / Display resolution 1 fpm Face velocity accuracy +/-10%Alarm delays User configurable – 0 to 60secsRelay output 4 (1 on board – 3 on optional plug in relay interface unit)Analog output 0-10V output, directly proportional to velocity (Optional)Relay input 3Comm. Port RS232 – Can be connected via Serial interface to LAN network (Full software available)Sash high indication Yes, with separate plug-in connectionNight setback YesExternal alarm indication YesPower Requirement Input–120VAC, 60Hz Output–15VDC, 500maUnits English and Metric (user selectable)Display–visual Analog bar graph or Fault Timeline LEDs: red, alarm; yellow, caution; green, normal Digital display of velocity reading (can be turned off)Alarm indication Red LED & audible alarm (to a certain sound spec)Horn silence Yes (temporary / permanent/automatic depending on type of alarm or external input)Mounting Semi FlushOperating temperature 55-86 F (13-30 C)Storage temperature -40-150 F (-40-65 C)Instrument dimensions Instrument Case: 5.2” H x 3.19” W x 1.14” D (132mm H x 81mm W x 29mm D)Agency listings UL & CE

Alarm range 30-400 fpm (.15 -2.0 m/s)Accuracy Face velocity accuracy +/- 10%Airflow sensor On-board or remote sensorCalibration Single or 2-point ( Installer selectable )Low Air Alarm delay Fixed 5 secsRelay output 1 -–( Low Air alarm )Analog output Not availableRelay input 2 – Night setback & sash highComm. Port RS232 – Can be connected via serial interface to LAN network (Full hood performance software reporting available)Sash high indication Yes – using a Micro switch or Proximity switch input With repeat alarm feature factory set to 5 min. (Can be adjusted via laptop up to 30 mins)Night setback Yes – using a relay inputExternal alarm indication Not availablePower Requirement Input—120VAC, 60Hz Output—15VDC, 500maDisplay—visual LEDs: red, alarm; green, normalAlarm indication Red LED & audible alarmHorn silence Yes – temporaryMounting Semi FlushOperating temperature 55-86 F (13-30 C)Storage temperature -40-150 F (-40-65 C)Instrument dimensions Instrument Case: 5.2” H x 3.19” W x 1.97” D (132mm H x 81mm W x 50mm D)Agency listings UL & CE

AFA 500Mk3

Fume Hood Airflow MonitorSpecifications

Part #AMS-ALRG

Air Monitor Alarms

telephone 231-798-1111 29

Ceiling Enclosures & Finished BacksAirMasterSystemsCorporationoffersceilingenclosuresandfinishedbackstoprovideaprofessional,finished

designinanysetting.Ceilingenclosuresandfinishedbacksarefabricatedofcoldrolledsteelandfinishedto

match the fume hood superstructure.

The ceiling enclosures are available in two types: for standard fume hoods and also for those fume hoods

utilizingtheoptionalAirChamber.Bothenclosuresconcealandprotectthehoodductwork,electricalconduit

and other supply lines.

Ceiling Enclosures & Finished Backs

Finished Backs: Order FINBACK-W where

W equals hood width.

Ceiling Enclosures: Order CE-W-H where W is hood width and H is height of enclosure required. Example: CE-48-18 is a set of enclosures for a 48” wide hood which are 18” high.

Finished backs are used to close off the back of the fume hood,

givingitafinishedlookwhenlocatedinthecenterofaroom.

www.airmastersystems.com30

Remote Control Fixtures

90º Water FaucetPart # FXTDS

Deck Mount WaterPart # FXTDMW

AllAirMasterSystemsCorporationremoteoperatedfixturescomestandardwithfour-pronghandles,bakedcolorcodedepoxyupperassembliesandcontrolrodscuttolength.Chromeandotherstylesareavailableuponrequest.Pre-plumbedservicesare3/8”blackpipeforgasesand1/2”rigidcopperwithsolderedjointsforwaterandotherlabservices.

Deck Mount GasSingle Outlet

Part# FXTDMG1

Deck Mount GasDouble Outlet

Part # FXTDMG2

Hot & Cold Water MixingPart # FXTCWM

Gooseneck Faucet with Vacuum Breaker

Part # FXTGNWVBSpecify Hot or Cold

Gooseneck FaucetPart # FXTGN

Specify Hot or Cold

Description Part #

Gas FXTGAS

Air FXTAIR

Vacuum FXTVAC

Nitrogen FXTNIT

Cold water FXTCW

Plumbing Accessories

Others available upon request

Panel Mounted Mixing Faucetwith Swing Spout, Lever Handles

Part # FXTPMSGN-6Part # FXTPMSGN-8Part # FXTPMSGN-10Part # FXTPMSGN-12Part # FXTPMSGN-14Part # FXTPMSGN-16

telephone 231-798-1111 31

Pre-Wire service is completed in accordance with NEC and UL-1805 standards.Note: If the fume hood is not pre-wired, wiring in the field must be accomplished using UL listed electrical fixtures while observing NEC standards and local electrical codes.

Electrical Accessories and Specifications

Single Pole 15 Amp Light Switch

Standard Black Color & Cover PlatePart# LTSW

Red Illuminated Toggle Switch with Black Cover Plate

Part# BLSW

Explosion Proof OutletClass 1, Group 1

Part# XPO

Explosion Proof SwitchClass 1, Group 1

Part# XSW

208 Volt, 20 Amp Single Pole Receptacle

230, 277 or other available upon request

Part# 208

120 volt 20 Amp Ground Fault Interrupter (GFI)

Duplex Outlet Standard Black color with cover

Part# GFI

Explosion Proof LightClass 1, Group 1

Available in incandescent or fluorescent

Part# XPL

www.airmastersystems.com32

Sash Options

Combo Horizontal/Vertical Sash

EH-121-72

Horizontal Sash Only

EH-131-72

Interlocking Sash

EH-141-72

Hanging Horizontal Doors

EH-451-72

Additional Sash Options

•SASHALARM: a red light alarm activated when sash is openedaboveapre-setheight

•SASHSTOP: a device to limit sash opening, with manual override

•AUTOSASHRETURN:returnssashto18”workingheight when opened beyond set height

•SASHINTERLOCK: allows only one sash to be opened at anytimeonadouble-sidedhood

•DOUBLEHUNGSASH:for larger openings with ceiling height limitations

•SASHLOCK: a keyed lock that keeps the sash closed if needed in a classroom setting

•PUSHBUTTONSASH*: opens and closes sash with the push of a button

•AUTO-SENSINGSASH*: automatically closes sash when operator walks away

Toordertheseoptionalsashes,pleaserefertotheOrderingGuideonthebackcoverofthiscatalog.Thelarge,underlined number in each of the part numbers below is the Sash Style number to use when ordering.

*These two types of sashes have a wide range of capabilities. Please call an Air Master Systems representative or the factory to determine which application is right for your needs.

telephone 231-798-1111 33

AlthoughAMSisyour fume hood expert, we do offer a limited selection of metal base cabinets manufactured by our approved cabinet suppliers to help you complete your fume hoodproject.Whena large quantity of standard laboratory cabinets is required, however, we suggest you work directly with oneoftheAMScabinetpartners.Callusforan approved list of suppliers.

AMSfumehoodbasecabinets conform to the method of testing and performance requirements set forth in theScientificApparatusMakersAssociation(SAMA).AllADAandhood base cabinets can be manufactured in stainless steel.

Base Cabinets

HBF-3048HBF-3348

ADA-3012ADA-3018ADA-3024

HB-3612*HB-3630HB-3636HB-3648

ASC-30ASC-36ASC-48

FSC-30FSC-36FSC-48

ROB-35

ADA Base Frames ADA Hood Bases

Must be specified left- or right-hand; right-hand shown

ADA-3312ADA-3318ADA-3324

Must be specified left- or right-hand

Hood Bases

EXAMPLE: HB-3630 = 36”h x 30”w

NOTE: These cabinets also come in 33” high and 30” high

*Single door; specify left- or right-hand

NOTE: ADA cabinet configurations come in both 30” and 33” high.

Acid Storage Cabinet

Acid cabinet can be painted

any standard color or safety blue.

Flammable Storage Cabinet Roll Out Flammable Storage Cabinet**

**Designed for kneespace application.

NOTE: All flammable storage cabinets come standard in safety yellow.

LEFT-HAND

RIGHT-HAND

www.airmastersystems.com34

Work SurfacesAnotherkeycomponentofeffective

andefficientfumehoodutilizationisthetypeofworksurfacetouse.Inappropriateworksurfaces can interfere with lab processes and beapotentialdangertolabpersonnel.AirMasterSystemsCorporationprovidesdurable,high-performanceepoxyresinandstainlesssteel surfaces that feature top quality materials and workmanship.

Epoxy Resin

Stainless Steel

Chemical Resistance S G

Heat Resistance S G

Stain Resistance G G

Moisture Resistance E S

Impact Resistance E S

Abrasion Resistance G E

Cleanability G E

Sanitation P E

Spill Containment G G

Maintenance Cost Low Low

Smoke Toxicity Low Low

Disposal Impact Low Low

S=Superior E=Excellent G=Good F=Fair P=Poor

The above chart of chemical resistance test results represents a sampling of data. Complete test results for additional solvents and chemicals can be obtained by contacting us.

Epoxy ResinPrimarily used for all general purpose fume hoodsandbasecabinets,AMSFumeHoodepoxyresintopsare1-1⁄4”(3.2cm)thickwithablack,lowsheenfinishandfeatureadeepdished3/8”(0.97cm)workarea.Oval3”x6”(7.65x15.3cm)cupsinksarestandard;locationsmustbespecifiedwhenordering.

Stainless SteelStainless steel work surfaces are fabricated of304stainlesssteel*,are1-1/4”(3.2cm)thickanddished3/8”witha#4smoothsatinfinish.Square3”x6”(7.65x15.3cm)weldedcupsinksarestandard;locationsmustbespecifiedwhenordering.

*In perchloric acid applications, 316 stainless steel is used for lab safety.

200 Series Epoxy Work Surfaces

Epoxy Resin & Stainless Steel Surfaces

300 Series Epoxy Work Surfaces

100 & 500 Series Epoxy Work Surfaces

800 Series Epoxy Work Surfaces

telephone 231-798-1111 35

TheAirChambersystemreducesenergycostsforheatingandcoolingtoanyfumehoodbyasmuchas70percent.This is achieved by capturing air from outside the laboratory and supplying it to the hood through a supply duct to the AddAirchamber.Anadditional,separateblowerandductare required for the air supply.

Increased FlexibilityTheAddAirchambercanbeusedonanyEliminatorhood

and coordinates with all Eliminator standard features in design,manufacturing,construction,finishing,andfixtures.

ToordertheAddAiroption,includethelettersAA”afterthewidthdimension.SeeOrderingGuide”onbackcover.

Optional feature reduces energy costs by up to 70 percent

Blower information is provided for general purposes only based on a full open sash and static pressure for the hood only. Corners and additional duct runs will increase the static pressure and blower requirements. Please consult with your HVAC professional for your specific requirements.

Supply Blower InformationModel 70% of Hood CFM SP @ Hood Duct Size

EH-111-36AC 400 .15 Inches 4” x 17”

EH-111-48AC 580 .18 Inches 4” x 17”

EH-111-60AC 765 .22 Inches 4” x 22”

EH-111-72AC 950 .28 Inches 4” x 22”

EH-111-96AC 1315 .42 Inches (2) 4” x 17”

Supply Blower InformationModel 70% of Hood CFM SP @ Hood Duct Size

EH-411-48AC 580 .18 Inches 4” x 17”

EH-411-60AC 765 .22 Inches 4” x 22”

EH-411-72AC 950 .28 Inches 4” x 22”

EH-411-96AC 1315 .42 Inches (2) 4” x 17”

Supply Blower InformationModel 70% of Hood CFM SP @ Hood Duct Size

EH-311-36AC 470 .15 Inches 4” x 17”

EH-311-48AC 645 .18 Inches 4” x 17”

EH-311-60AC 820 .22 Inches 4” x 22”

EH-311-72AC 995 .28 Inches 4” x 22”

EH-311-96AC 1345 .42 Inches (2) 4” x 17”

The Eliminator Air Chamber–an option for all hood styles

www.airmastersystems.com36

QUICK SHIP Fume Hoods, Epoxy Tops and Base CabinetsAllAMSQUICKSHIPproductsshipwithin10days.Someitemsareavailablewithin24hours.Fordetailedinformation and available quantities, go to www.airmastersystems.com, contact a factory representative or callAMSdirectly.

HOOD ONLY100 Series Hoods

QS-148QS-160QS-172

HOOD, TOP AND SINK100 Series Hoods

QS-148-TSQS-160-TSQS-172-TS

NOTE: Allhoodscomewithlightswitch,blowerswitch,twoGFIoutlets,onegasspout,oneCWdownspout,prewiredandpreplumbed on the right.

QUICK SHIPFume Hoods and Epoxy Tops

HOOD BASESQS-12-HBQS-30-HBQS-36-HBQS-48-HB

QUICK SHIPBase Cabinets

All QUICK SHIP products come in standard Champagne color.

ADA CONFIGURATIONSQS-12-ADA BASE CABINETQS-48-ADA BASE FRAME

FLAMMABLE STORAGE CABINETSQS-30-FSCQS-36-FSCQS-48-FSC

COLOR: Safety Yellow

ACID STORAGE CABINETSQS-30-ASCQS-36-ASCQS-48-ASC

COLOR: Safety Blue

For additional detailed information, see page 33.

telephone 231-798-1111 37

QUICK SHIP Stainless Steel Products

Stainless Steel Wall Shelving Model Dimensions B x A

WS-1224 12”x24”

WS-1236 12”x36”

WS-1248 12”x48”

WS-1260 12”x60”

WS-1272 12”x72”

WS-1296 12”x96”

WS-1624 16”x24”

WS-1636 16”x36”

WS-1648 16”x48”

WS-1660 16”x60”

WS-1672 16”x72”

WS-1696 16”x96”

Most stainless steel items ship within 72 hours— please check www.airmastersystems.com for availability.

Stainless Steel Drop-in Sinks Model Dimensions

DIS-15155 15”x15”x5”

DIS-14101 14”x10”x10”

DIS-14105 14”x10”x5”

DIS-16145 16”x14”x5”

Stainless Steel Work Tables and Sinks

Model Length = A

WT-3-1818-12 90” w/3 sinks

WT-3-1620-12 84” w/3 sinks

WT-3-1014-10 60” w/3 sinks

Other sizes and configurations available upon request—please call for a quote.For more information and available quantities, go to www.airmastersystems.com

Specialty Hand Steel Sinks/Wall Mount

Model Sink Size

AMHS-W-SS 9” x 9” x 4-1/4”

AMHS-ADA-S 14”x 16”x 5”

Drip Troughs with TubingModel Size

AMHDT-18-2 18”

AMHDT-24-2 24”

AMHDT-30-2 30”

AMHDT-36-2 36”

Stainless Steel Pegboards with Pegs

Model Size

AMV2430 24”w x 30”tall 32 pegs

AMV3030 30”w x 30”tall 50 pegs

AMV3024 30”w x 24”tall 25 pegs

AMV3630 36”w x 30”tall 60 pegs

Stainless Steel Double-Locking Narcotics Cabinet

Model Size

AMNL-2K 12”x 13”x 10”deep

www.airmastersystems.com38

Primarily used for all general purpose fume hoods and base cabinets, standard stainless steel countertops are fabricated of16-gauge304*stainlesssteelwitha#4smoothgrainfinishandare11⁄4”(3.2cm)thickanddished3/8”(0.97cm).A4”integral back splash comes standard and, when sinks or end splashes are required, they are continuously welded to the top and professionallybuffedtoa#4finish.Standarddepthis30”andtheycanbemadeuptoanylengthrequiredtoincludeafieldjointorcontinualcounterdependingonthespecificjobrequirements.Thetopsalsohavearubberizedsounddeadeningmaterialappliedto soften the sound of the top and make it more acoustically appealing.

Square3”x6”(7.65x15.3cm)weldedcupsinks are standard; locations must be specifiedwhenordering.

*Use of perchlorics requires use of 316 stainless steel for lab safety.

SECTION THRUSECTION THRU

SPECIAL COUNTERTOP w/DOUBLE SINK SPECIAL COUNTERTOP w/EXTRA DEEP SINK

MARINE EDGE COUNTERTOPS ALSO AVAILABLE

SECTION THRU

Custom Stainless Steel Countertops

telephone 231-798-1111 39

Callforpricing.

Lattice Assembly

Callforpricing.

Peg Boards

Blowers, Lattice Assemblies and Peg Boards

AirMasterSystemscansupplytheblower units for all your fume hood needs. OurstandardblowersareallAMCA(AirMovementandControlAssociation)certifiedrated. The blowers are available in direct drive,beltdriveandFRP(fiberglassreinforcedplastic)tomeetstheneedsofyour laboratory environment. Please contact our customer service department to help chose the right fan for your application.

Latticeassemblies,commonlyreferredtoas

monkeybars,”areneededforcomplexdistillation

setups.Standarddesignsaremadewith1/2”solid

aluminumrod.Theyarealsoavailablein304

stainlesssteel.Manydifferentsizesareavailable;

please call a factory representative for details.

Blower

AMSstainlesssteelpegboardsaredesignedto

accommodate every application. These boards are

available in stainless steel or acrylic, and can be

wall mounted, freestanding, or may be used with

wallstandardstoallowforheightadjustments.

Thereisafinishedbackoptionforuseinisland

endapplications.Contactafactoryrepresentative

forsizesandavailability.

www.airmastersystems.com40

Knock Down Hoods

MostAMShoodscanbeknockeddowninto manageable modules. This can be very usefulwhenretrofittingoldlabs,orforeasierinstallation of large hoods. This feature also allows for container shipment packaging. ContactyourcustomerservicerepresentativeforacopyoftheHow-Tovideo.

Easy disassembly and reassembly for a multitude of applications

telephone 231-798-1111 41

1.01 FUMEHOODGENERALDESIGNREQUIREMENTS A. Fumehoodsshallfunctionasventilated,enclosed

workspaces,designedtocapture,confineandexhaust fumes, vapors and particulate matter produced or generated within the enclosure.

B. Designfumehoodsforconsistentandsafeairflowthroughthehoodface.Negativevariationsoffacevelocityshallnotexceed20%oftheaverageface velocity at any designated measuring point as definedinthissection.

C. Averageilluminationofworkarea:Minimum80foot-candles.Workareashallbedefinedastheareainside the superstructure from side to side and from face of baffle to the inside face of the sash, and fromtheworkingsurfacetoaheightof28inches.

D. Fumehoodshallbedesignedtominimizestaticpressure loss with adequate slot area and stainless stealexhaustcollarconfiguration.Maximumaveragestatic pressure loss readings taken three diameters abovethehoodoutletfromfourpoints,90degreesapart, shall not exceed the following maximums.

FaceVelocity MeasuredS.P.L.(W.G) F.P.M. .18inches 100F.P.M. .30inches 125F.P.M. .45inches 150F.P.M. .60inches

E. Fume hood shall maintain essentially constant exhaust volume at any baffle position for safety. MaximumvariationinexhaustCFM,staticpressureand average face velocity as a result of baffle adjustmentshallnotexceed10%foranybafflepositionatthespecifiedfacevelocity.

1.02 SUBMITTALS

A. ShopDrawings:Indicateequipmentlocations,large-scale plans, elevations, and cross sections, rough in and anchor placement dimensions and tolerances and all required clearances.

B. ProductData:Submitmanufacturer’sdataforeach component and item of laboratory equipment specified.Includecomponentdimensions,configurations,constructiondetails,jointdetails,and attachments, utility and service requirements and locations.

C. Samples:Submit3”x6”inchsamplesoffinishfor fume hood, work surfaces and for other pre finishedequipmentandaccessoriesforselectionbyArchitect.

D. TestReports:Submittestreportsverifyingconformance to test performances specified.Submitindependenttestsasspecified.

1.03 QUALITYASSURANCE

A. Singlesourceresponsibility:Fumehoodcasework,work surfaces, and other laboratory equipment and accessories shall be manufactured or furnished by a single laboratory furniture company.

B. Manufacturer’squalifications:Modernplantwithpropertools,dies,fixturesandskilledworkertoproduce high quality laboratory casework and equipment, and shall meet the following minimum requirements:

1. Fiveyearsormoreexperienceinmanufactureoflaboratory casework and equipment of type specified.

2. Teninstallationsofequalorlargersizeandrequirements.

C. Installer’squalifications:Factorycertifiedbythemanufacturer.

1.04 DELIVERY,STORAGEANDHANDLING

A. Scheduledeliveryofequipmentsothatspacesaresufficientlycompletethatequipmentcanbeinstalled immediately following delivery.

B. Protectfinishedsurfacesfromsoilingordamageduringhandlingandinstallation.Keepcoveredwithpolyethylenefilmorotherprotectivecoating.

C. Protectallworksurfacesthroughoutconstructionperiodwith1/4”corrugatedcardboardcompletelycovering the top and securely taped to edges. Mark cardboardinlargeletteringNoStanding.”

1.05 PROJECTCONDITIONS

A. Donotdeliverorinstallequipmentuntilthefollowing conditions have been met:

1. Windowsanddoorsareinstalledandthebuildingissecure and weather tight.

2. Plumbing,overheadductworkandlightingareinstalled.

3. Allpaintingiscompletedandfloortilelocatedbelowcasework is installed.

Fume Hood General Design Requirements

www.airmastersystems.com42

Fume Hood General Design Requirements (continued)

2.01 FUMEHOODMATERIALS

A. Steel:Highquality,coldrolled,mildsteelmeetingrequirementsofASTMA366;gaugesU.S.Standard.

B. StainlessSteel:Type304;gaugesU.S.Standard.

C. Ceilingclosurepanels:Minimum18gauge;finishtomatch hood exterior.

D. Bypassgrilles:Lowresistanttype,18gaugesteel,upward directional louvers.

E. Safetyglass:7/32”thicklaminatedsafetyglass.

F. Sashcables:7x7steel,coated,1/16”diametercoatedto3/32”.(Militaryspec.quality.)

G. Sashguides:Afulllengthextrudedcorrosionresistant polyvinyl chloride or powder coated steel withPVCguidestoprotectagainstmetaltometalcontact.

H.Pulleyassemblyforsashcable:2”diameter,nylontired, ball bearing type, with cable retaining device.

I. Sashpull:Fullwidth16gaugesteeltomatchhoodcolor.

J. Interioraccesspanels:Tobemadeofthesamematerial as the fume hood liner. Panels are to be heldinplacebymeansofanon-mechanicaltypefastening systems.

K. Fastenings: 1. Exteriorstructuralmembersattachments:Sheet

metalscrews,zincplated. 2. Interiorfasteningdevicesconcealed.Exposed

screws not acceptable. 3. Exteriorpanelmemberfasteningdevicestobe

corrosionresistantnon-metallicmaterial.Exposed screws not acceptable.

2.02 FUMEHOODCONSTRUCTION

A. Superstructure:Rigid,self-supportingassemblyofdoublewallconstruction,maximum5-1/4”thick.

1. Wallconsistsofasheetsteeloutershellandacorrosion resistant inner liner, and houses remoteoperatingservicefixturemechanismsand electrical services.

2. Accesstofixturevalvesconcealedinwallprovidedby exterior removable access panels, access

panels on the inside liner walls, or through removable front posts.

3. Hoodsmustbeoffullframeconstruction.Hoods that use metal brackets and spacers to hold interior and exterior panel in place are unacceptable.

B. Exhaustoutlet:10”round,20gaugestainlesssteelexhaust collars.

C. Accessopeningperimeter:Topandsidesoffaceopening to be radiuses or angled.

1. Bottomhorizontal:foilshallbeaflushmounttypeandprovidea1”bypasstoinsureacleansweepandtominimizeeddiesalongtheworksurfacewhen sash is in the closed position.

2. Bottomsashrail:1-1/2”framesection,16-gaugesteelorPVC.Provideflushpull,fullwidthofbottom rail.

3. Setsafetyglassintorailsindeepform,extrudedpolyvinylchlorideorneopreneglazingchannelsif a steel sash frame is being used.

4. Counterbalancesystem:Singleweight,pulley,cable, counter balance system which prevents sashtiltingbymeansofashaftdriven”systemandpermitsonefingeroperationatanypointalong full width pull. Sash not using this type of counter balance systems are unacceptable. Maximum9poundspullrequiredtoraiseorlower sash throughout its full length of travel. Designsystemtoholdsashatanypositionwithout creep and to prevent sash drop in the event of cable failure.

5. Openandclosesashagainstrubberbumperstops.

D. Fumehoodliner:1/4”Polyresin:Reinforcedpolyesterpanelsmoothfinishandwhitecolorinfinalappearance.Flexuralstrength:14,000psi.Flamespread:15orlessperU.L.723andASTME84-80.

E. Baffles:Fabricatefixed”bafflesprovidingcontrolledair vectors into and through the fume hood of the samematerialastheliner.Hoodswithadjustablebafflesareunacceptable.Allbafflesupportbracketstobenon-metallic.

F. Servicefixturesandfittings:Colorcodedhosenozzleoutlets and valves mounted inside the fume hood and controlled from the exterior with color coded indexhandles(whenspecified).

1. Valves:Needlepointtypewithself-centeringconetip and seat of hardened stainless steel.

2. Providepre-pipingforallservicefixturesfromvalvetocommonpointforfinalconnectionbyrespectivetrades.Copperforwater,airand

telephone 231-798-1111 43

Fume Hood General Design Requirements (continued)

vacuum and black iron for gas services. 3. Fixturesexposedtohoodinterior:Brasswith

chemically resistant powder coating. 4. Remotecontrolhandles:Prongtype,easytograsp. 5. Services:Asfollows:Gas,water,air,andvacuum.

G. Hoodlightfixtures:Twolamp,rapidstart,T-8ULlistedfluorescentlightfixturewithsoundratedballast installed on top panel.

1. Interioroffixture:White,highreflectingplasticenamel.

2. Provide:Removablesafetyglasspaneloninteriorofhoodforre-lampingoflights.

3. Sizeoffixture:Largestpossibleupto48”forhoods with superstructures up to six feet. Providetwo24”fixturesforhoodswitheightfoot superstructures.

4. Includelampswithfixtures. 5. Illumination:Perperformancevalues,part1ofthis

section. 6. Provide switch with black acid resistant

thermoplastic(whenspecified). 7. 3-wayswitchoneachsideofdoublesidedhoods

(whenspecified).

H. Electrical services: Provide on each front post of hoods. Three wire grounding type receptacles rated at120vGFI,20ampereswherespecified.FlushPlates: Black acid resistant thermoplastic.

I Worksurfaces:1-1/4”thickdishedanominal1/4”to contain spills.

1. MoldedresinworksurfacesforhoodswithwhiteResistoRocorPoly-resinliners.Frontraisededgenomorethan1/2”wide.

J. SafetyMonitor/AlarmSystem:ProvidesafetyMonitor/Alarmsystemthatmonitorsfacevelocityand provides audible and visual alarm if face velocity drops below safe levels. The technology usedintheTEL1000/1willbebasedonthermallycompensated thermistor based in the alarm module. Astheinternalfumehoodpressurechangesasthesash opening is closed and opened, the flow passing over the thermistor is calibrated to a face velocity that is displayed on the front of the monitor.

1. Safetymonitor:ULlisted,tamperproof,withallalarm circuits, electric components, external tubing, and manifolds furnished complete and factory installed. Monitor shall have light emitting diode display that provides clear indication of airflow conditions.

2. Calibrationistheresponsibilityoftheownerandis required once the hood is stationed and the hood exhausts and room supply systems are

balanced.Asecondarycalibrationhasbeenfactory set into the alarm’s memory only to determine that the alarm is functional and ready for shipment. The primary calibration must be completedinthefield.

3. Airflowsensor:Thermallycompensatedglassbeaded thermistor, factory connected to a sidewall port on the interior of the fume hood.

4. AlarmSignal:Audiblesignalandvisual,redlightemitting diode:

a. Silence pushbutton, which disables the audible alarm, shall be accessible on the front of the safety monitor.

b. Provide alternate mode in which visible alarm issilencedindefinitelybutvisualalarmremains activated until the alarm condition is corrected.

c. Whenalarmconditioniscorrectedandfacevelocityandvolumereturntospecifiedlevels,the Safety Monitor will automatically reset and begin routine monitoring.

d. Provide test circuit to verify proper Safety Monitor operation.

e. Electricalrating:Maximum12VDC,andmaximumcurrentratingof20OMA.

f. Provideaoptionforasashalarm/sensorifrequired.

2.03 CEILINGENCLOSURE:Provideceilingenclosurefromtopofhoodtoaccommodateaceilingheight(verify).Fabricateenclosurefrom18gaugesteeltomatchthehoodmaterialandfinish.

A. Preparation:Spraycleanmetalwithaheatedcleaner/phosphatesolution.

B. Application:Electrostaticallyapplypowdercoatof selected color and baked in controlled high temperature oven to assure a smooth, hard satin finish.Surfacesshallhaveachemicalresistant,highgradelaboratoryfurniturequalityfinishofthefollowing thickness:

1. Exteriorandinteriorsurfacesexposedtoview:1.5milaverageand1.2milminimum.

2.04 SOURCEQUALITYCONTROL

A. Demonstratefumehoodperformancebymeansofdocumentation of a third party testing company to theASHRAE110-1995methodsoftesting.

www.airmastersystems.com44

Airfoil: Shaped or streamlined member at hood entrance designed to enhance movement of air into the hood

Air Volume:Rateofairflow,normallyexpressedincubicfeetperminute(CFM)

ASHRAE:AmericanSocietyofHeating,Refrigerating,andAirConditioningEngineers,aprofessionalorganizationthat sets industry standards for fume hood testing procedures

Auxiliary Air: Supply or makeup air delivered external to the chamber of a fume hood to reduce air consumption

Baffle: Panels located across back of hood interior, which control pattern of air moving through the hood

Blower:Airmovingdevice(orfan)consistingofmotor,impeller, and scroll

Bypass:Compensatingopeningthathelpsmaintainconstant volume exhaust from fume hood, regardless of sash position

Canopy Hood:Ceilingorwallsuspendedventilatingdevice for noncritical use with heat, water vapor, odors, etc.

CFM:CubicFeetPerMinute,aunitofmeasurementofair volume

Combination Sash:Horizontalpanelsinaverticallyrisingframe; see sash

Constant Volume: Type of fume hood exhaust system that exhausts the same volume of air, regardless of sash position

Containment:Extenttowhichfumesareconfinedwithinthe hood compartment

Damper:Deviceinstalledinducttocontrolairvolume

Demonstration Hood: Fume hood with glass panels on two or three sides to improve visibility for demonstrating experiments in a classroom setting

Exhaust Volume/Parameters:Quantityofairexhaustedbythe fume hood; quantity of air required to maintain desired face velocity, expressed in cubic feet per minute(CFM)

Face Velocity: Speed of air moving into the fume hood throughthefaceopening(throughthesash),measuredinfeetperminute(FPM)

FPM: Feet per minute; measurement of air velocity

Liner: Fume hood interior sides, back, and top, including baffle

Lintel: Portion of fume hood front located above access opening

Louvers:Slit-likeopeningsinthelintelthatallowbypassair to enter the hood when the sash is closed

NFPA:NationalFireProtectionAssociation

Negative Pressure: Pressures lower than one atmosphere

Positive Pressure: Pressures higher than one atmosphere

Restricted Bypass Fume Hood: Fume hood operating type, designed with limited bypass area; commonly used in conjunctionwithVariableAirVolume(VAV)exhaustsystems and restricted sash opening designs

Sash: Sliding glass panel set in the fume hood face that provides access to the hood interior

Service Fitting/Plumbing:Waterfaucetsandgasvalvesmounted on or fastened to the fume hood

Static Pressure:Airpressure,orresistance,infumehoodor duct, expressed in inches of water

U.L. 1805:UnderwritersLaboratoriescertificationthatverifiesconformancetoelectrical,mechanical,andairflow standards

Variable Air Volume (VAV): Type of fume hood exhaust system that typically maintains constant fume hood facevelocitybyadjustingblowermotorspeedora balance damper in response to changes in sash position

Velocity: Speed of air, measured in feet per minute (FPM)

Velocity Pressure: Force per square inch applied by moving air

Volume:Quantityofair,usuallymeasuredincubicfeetperminute(CFM)

Work Surface: Top material; area in fume hood where apparatus rests and where work takes place

Fume Hood Technology — Glossary of Terms