Page 1: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

Merchandisers

®

Air Flow Clearances for Merchandiser Layouts

Hussmann Self-Contained Merchandisers

November 2014

LTHBCH HGL HGM DDSS

MD SHMGSVM NIM-6NAV

LBN ISF / ISM SN / SM HSD

U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • www.hussmann.com

Page 2: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead
Page 3: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

P/N iii

IMPORTANTKEEP IN STORE FOR FUTURE REFERENCE

Quality that sets industry standards!

12999 St. Charles Rock Road • Bridgeton, MO 63044-2483

U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900

www.hussmann.com© 2014 Hussmann Corporation

M erchandiser m ust operate for 24 hours before loading product!

Regularly check m erchandiser tem peratures.

Do not break the cold chain. Keep products in cooler before loading into m erchandiser.

These m erchandisers are designed

for pre-frozen and / or pre-chilled products only.

Page 4: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

SELF-CONTAINED CLEARANCES

BCH & LTH ............................................ 1, 2HGL & HGM .............................................. 3DDSS & MD ................................................ 4GSVM & SHM ............................................. 5NAV ............................................................. 6NIM-6 & LBN.............................................. 7ISF ................................................................ 8SN / SM ........................................................ 9HSD ........................................................... 10

TABLE OF CONTENTS v

U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • www.hussmann.com

Page 5: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

Air Flow CleArAnCes 1

Air flow must be considered when positioning merchandisers near walls, other merchandisers and areas where air currents exist. Decreased efficiency and cooling occurs when warm air is discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead to refrigeration failure and product spoilage. Not all models take in or discharge air in the same manner. Refer to the illustrations of the different models types to learn details about each model’s air flow clearance requirements.

36 in. 36 in. 36 in.

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides and Rear

36 in. Clearance at Front

(Plan View)

Air Intake

Air Intake

Front Rear

Zero Clearance at Sides and Rear

36 in. Clearance at Front

(Plan View)

Air Intake

Air Intake

Front Rear

Zero Clearance at Sides and Rear

36 in. Clearance at Front

(Plan View)

Air Exhaust

Air Exhaust

NOTE : The clearance requirements for these merchandisers are the recommended minimum distances to keep merchandisers from being affected by air currents.

LTHBCH 8 18

45

68

8

1845

68

* LTHs can be pushed against the wall.

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

Page 6: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

2

U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • www.hussmann.com

Im proper Air Flow

Im proper Air Flow

A merchandiser’s air flow can be disturbed by the air flow from adjacent merchandisers. In this illustration the LTH-18 is placed on the wrong side of this merchandiser lineup. LTH-18 and BCH-18 merchandisers must be placed on the left-hand side of the lineup to prevent the middle merchandiser from drawing warm air.

The illustration below is a lineup of LTH merchandisers properly placed next to each other in series. Notice the air intake arrows are pointed in the same direction for merchandisers located next to each other.

Im proper Air Flow

Im proper Air Flow

Page 7: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

Air Flow CleArAnCes 3

HGL

24 in. 6 in.

6 in.24 in.

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

24 in. Clearance at Front 6 in. Clearance

at Rear

(Top View)Air

Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

12 in. Clearance at Rear and on Top

(Top View)

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

24 in. Clearance at Front 6 in. Clearance

at Rear

(Side View)

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

12 in. Clearance at Rear and on Top

(Side View)

(Condensing Unit)

24 in. 6 in.

6 in.24 in.

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

24 in. Clearance at Front 6 in. Clearance

at Rear

(Top View)Air

Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

12 in. Clearance at Rear and on Top

(Top View)

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

24 in. Clearance at Front 6 in. Clearance

at Rear

(Side View)

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

12 in. Clearance at Rear and on Top

(Side View)

(Condensing Unit)

HGL-BS and HGM-BS models must have a 6-in. clearance at the rear and a 24-in. clearance in front. All merchandiser grilles must remain free of dust and debris for optimal performance.

HGL-TS and HGM-TS have a condensing unit at the top. These models require a 12-in. clearance at the top and rear.

NOTE: Always place the singe door case on the left side when placing one and three-door HGL/HGMs in a line-up to avoid airflow problems.

24 in. 6 in.

6 in.24 in.

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

24 in. Clearance at Front 6 in. Clearance

at Rear

(Top View)Air

Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

12 in. Clearance at Rear and on Top

(Top View)

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

24 in. Clearance at Front 6 in. Clearance

at Rear

(Side View)

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

12 in. Clearance at Rear and on Top

(Side View)

(Condensing Unit)

24 in. 6 in.

6 in.24 in.

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

24 in. Clearance at Front 6 in. Clearance

at Rear

(Top View)Air

Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

12 in. Clearance at Rear and on Top

(Top View)

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

24 in. Clearance at Front 6 in. Clearance

at Rear

(Side View)

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides

12 in. Clearance at Rear and on Top

(Side View)

(Condensing Unit)

HGM

NOTE: HGM-2BS merchandisers require the same clearance space, but the air flow is different as shown in the illustration at right. Avoid installing 1-door merchandisers on the left side of the case.

Page 8: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • www.hussmann.com

4

DDSS

MD 36 in.

Air ExhaustAir Intake

Keep discharge and intake areas free from air currents.

M aintain 4 in. Clearance

Air Intake

Front Rear

Zero Clearance at Sides

5 in. Clearance at Rear

24 in. Clearance at Front

(Plan View)

Air Exhaust

36 in.

Air ExhaustAir Intake

Keep discharge and intake areas free from air currents.

M aintain 4 in. Clearance

Air Intake

Front Rear

Zero Clearance at Sides

5 in. Clearance at Rear

24 in. Clearance at Front

(Plan View)

Air Exhaust

Air ExhaustAir Intake

Keep discharge and intake areas free from air currents.

M aintain 4 in. Clearance

M aintain 4 in. Clearance

(Plan View)

Front

Air Exhaust

Back

Air Intake

Air ExhaustAir Intake

Keep discharge and intake areas free from air currents.

M aintain 4 in. Clearance

M aintain 4 in. Clearance

(Plan View)

Front

Air Exhaust

Back

Air Intake

DDSS models must have a 4-in. clearance at the rear.

MD models must have a 24-in. clearance in the front and a 6-in. clearance at the rear.

Page 9: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

Air Flow CleArAnCes 5

24 in.

6 in.

Air Intake

Air Exhaust

Front

M aintain 1 in. Clearance around Sides and Rear

of M erchandiser

M aintain 24 in. Clearance at Front of M erchandiser

Rear

Air Intake

Air Exhaust

Front Rear

M aintain 6 in. Clearance at Front of M erchandiser

Zero Clearance at Sides

24 in. 24 in. 5 in.

Air Intake

Air Exhaust

Front

M aintain 1 in. Clearance around Sides and Rear

of M erchandiser

M aintain 24 in. Clearance at Front of M erchandiser

Rear

Air Intake

Air Exhaust

Front

M aintain 1 in. Clearance at Sides

M aintain 24 in. Clearance at Front of M erchandiser

Rear

M aintain 5 in. Clearance at Rear

SHM

24 in. 24 in. 5 in.

Air Intake

Air Exhaust

Front

M aintain 1 in. Clearance around Sides and Rear

of M erchandiser

M aintain 24 in. Clearance at Front of M erchandiser

Rear

Air Intake

Air Exhaust

Front

M aintain 1 in. Clearance at Sides

M aintain 24 in. Clearance at Front of M erchandiser

Rear

M aintain 5 in. Clearance at Rear

24 in.

6 in.

Air Intake

Air Exhaust

Front

M aintain 1 in. Clearance around Sides and Rear

of M erchandiser

M aintain 24 in. Clearance at Front of M erchandiser

Rear

Air Intake

Air Exhaust

Front Rear

M aintain 6 in. Clearance at Front of M erchandiser

Zero Clearance at Sides

GSVM models have a 24-in. clearance in the front, a 1-in. clearance at the sides and a 5-in clearance at the rear.

SHM models have a 24-in. clearance in the front, a 1-in. clearance at the sides, and a 1-in clearance at the rear.

GSVM

Page 10: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • www.hussmann.com

6

NAV

24 in.

Air Intake

Air Exhaust

Front Rear

M aintain 4 in. Clearance around Sides and Rear

M aintain 24 in. Clearance at Front

(Plan View)

NAV / NAVC models must have a 24-in. clearance in the front, a 1-in. clearance at the sides, and a 1-in. clearance at the rear.

24 in

.

24 in

.

Air Intake

Air Exhaust

Front

Rear

M aintain 4 in. Clearance around Sides and Rear

M aintain 24 in. Clearance at Front

(Plan View)

Air Intake

Air Exhaust Front

Rear

M aintain 4 in. Clearance around Sides and Rear

M aintain 24 in. Clearance at Front

(Plan View)

Im proper Air Flow

Merchandisers must not draw in air from the warm exhaust of another merchandiser. Do not place these NAV models end to end.

Page 11: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

Air Flow CleArAnCes 7

NIM-6

36 in.36 in.

Air Intake

Air Exhaust

Front Rear

Zero Clearance at Sides36 in. Clearance at Front 36 in. Clearance

at Rear

(Plan View)

NIM-6 models must have a 36-in. clearance in the front and a 36-in. clearance at the rear.

LBN 24 in. 24 in.

Air Intake

Air Exhaust

Front

Zero Clearance around Sides and Rear

of M erchandiser

M aintain 24 in. Clearance at Front of M erchandiser

Rear

Air Intake

Air Exhaust

Front

Zero Clearance around Sides

of M erchandiser

M aintain 24 in. Clearance at Front of M erchandiser

Rear

2 in. Clearance at Rear

24 in. 24 in.

Air Intake

Air Exhaust

Front

Zero Clearance around Sides and Rear

of M erchandiser

M aintain 24 in. Clearance at Front of M erchandiser

Rear

Air Intake

Air Exhaust

Front

Zero Clearance around Sides

of M erchandiser

M aintain 24 in. Clearance at Front of M erchandiser

Rear

2 in. Clearance at Rear

LBN models must have a 24-in. clearance in the front. LBN-10 merchandisers have a 2-in. clearance at the rear.

Page 12: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • www.hussmann.com

8

ISF / ISM4 in. Clearance

Air Exhaust

M aintain 4 in. Clearance Around M erchandiser

Air Intake

Air Intake

Air Exhaust

(Plan View)

Keep discharge and intake areas free from air currents.

ISF / ISM models must have a 4-in. clearance around all sides of these merchandisers. Do not block the vented base panels. Product must not be placed outside of the designated load limits.

Merchandisers must not draw in air from the warm exhaust of another merchandiser. IS models placed in close proximity must have the air discharge directed toward the inside of the two merchandisers. This prevents warm discharge air from being directed towards the air intake of another merchandiser. See the illustrations below.

Intake

Correct Placem ent (Plan View)

M aintain 4 in. Clearance Around M erchandiser

Air Exhaust

Air Exhaust

Air

Air Intake

M aintain 4 in. Clearance Around M erchandiser

Incorrect Placem ent (Plan View)

Air Intake

Air Intake

Im proper Air Flow

Intake

Correct Placem ent (Plan View)

M aintain 4 in. Clearance Around M erchandiser

Air Exhaust

Air Exhaust

Air

Air Intake

M aintain 4 in. Clearance Around M erchandiser

Incorrect Placem ent (Plan View)

Air Intake

Air Intake

Im proper Air Flow

4 in. Clearance

Air Exhaust

M aintain 4 in. Clearance Around M erchandiser

Air Intake

Air Intake

Air Exhaust

(Plan View)

Keep discharge and intake areas free from air currents.

Page 13: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

Air Flow CleArAnCes 9

24 in.

Air Intake

Air Exhaust

Condensing Unit Access Panel

M aintain 4 in. Clearance around M erchandiser

Rear

SN / SM

SN / SM models must have a 4-in. clearance around all sides of these merchandisers.

Air Intake

Air Exhaust

Condensing Unit Access Panel

Air Intake

Air Exhaust

Condensing Unit Access Panel

M aintain 4 in. Clearance around M erchandisers

Air Intake

Air Exhaust

Condensing Unit Access Panel

Air Intake

Air Exhaust

Condensing Unit Access Panel

M aintain 4 in. Clearance around M erchandisers

Air Exhaust

Air Exhaust

Im proper Air Flow

Page 14: Air Flow Clearances for Merchandiser Layouts€¦ · discharged from one merchandiser’s air exhaust and is directed to another merchandiser’s air intake. Over time, this can lead

U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • www.hussmann.com

10

HSD

Air Intake

Air Exhaust

M aintain 5 in. Clearance

Step

Front

Zero Clearance this Side

HSD models must have a 4-in. clearance around all sides of these merchandisers.