air compressor technoworker mv 50 l ... - amazon web …

24
AIR COMPRESSOR Technoworker MV 50 L / Technoworker MV 100 L Original instructions manual Read these instructions before use. Failure to observe the instructions can result in serious injury and / or damage to the device! Save the instructions for use.

Upload: others

Post on 23-Apr-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

AIR COMPRESSOR Technoworker MV 50 L / Technoworker MV 100 L Original instructions manual

Read these instructions before use. Failure to observe the instructions can result in serious injury and / or damage to the device! Save the instructions for use.

Page 2: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Explanation of symbols:

Read and follow the operating and safety instructions before you start working with this power tool.

High-voltage, danger to life!

Always wear ear protection

Compressor unit may start without warning

Do not open the valve before connecting the hose

Danger: Hot surface

Never use the compressor in rain or wet weather

Check the power cable before use and if you find that the cable is damaged, be sure to unplug the compressor and replace the cable.

Do not use portable compressor with open case

Caution! Before using for the fi first time, check the oil level and the oil sealing plug!

Never direct compressed air at people or animals

Electrical appliances must not be disposed of with the domestic waste.

Only for home/hobby use IP 20 Protection degree

General warning sign

The device is in compliance with applicable European directives and regulations.

Page 3: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Dear customer,

Thank you for choosing compressors. We hope that your new tool will bring you enjoyment and success.

Note:

According to the applicable product liability laws, the manufacturer of the device does not assume liability for damages to the product or damages caused by the product that occurs due to: Improper handling, Non-compliance of the operating instructions, Repairs by third parties, not by authorized service technicians, Installation and replacement of non-original spare parts, Application other than specified, A breakdown of the electrical system that occurs due to the non-compliance of the

electric regulations and VDE regulations.

Intended use:

The compressor is designed and designed exclusively for the production of compressed air for tools - using compressed air. It is intended exclusively for private use and is not suitable for business purposes. Only use the compressor in the manner described in the operating instructions. Any other use is considered unintended - and can cause material damage or even damage to persons. The compressor is not a toy for children. The manufacturer or seller does not assume liability for any damage resulting from misuse or improper use. Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the equipment is used in commercial, trade or industrial businesses or for equivalent purposes.

Attention!

The device and packaging materials are not toys! Children must not be allowed to play with plastic bags, film and small parts! There is a risk of swallowing and suffocation!

Page 4: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

General safety instructions Attention! The following basic safety measures must be observed when using electric tools for protection against electric shock, and the risk of injury and fire. Read all these notices before using the electric tool and keep the safety instructions for later reference. Attention! The following basic safety actions must be taken when using this compressor in order to protect the user from electric shocks and the risk of injury and fire. Read and follow these instructions before using the equipment.

Safe work 1. Keep the work area orderly (clean and dry).

- Disorder in the work area can lead to accidents. 2. Take environmental influences into account.

- Do not expose electric tools to rain. - Do not use electric tools in a damp or wet environment. There is a risk of

electric shock! - Make sure that the work area is well-illuminated. - Do not use electric tools where there is a risk of fire or explosion.

3. Protect yourself from electric shock. - Avoid physical contact with earthed parts (e.g. pipes, radiators, electric ranges,

cooling units). 4. Keep children away.

- Do not allow other persons to touch the equipment or cable, keep them away from your work area.

5. Securely store unused electric tools - Unused electric tools should be stored in a dry, elevated or closed location out

of the reach of children. 6. Do not overload your electric tool

- They work better and more safely in the specified output range. 7. Wear suitable clothing

- Do not wear wide clothing or jewellery, which can become entangled in moving parts.

- Rubber gloves and non-slip shoes are recommendedwhen working outdoors. - Tie long hair back in a hair net.

8. Do not use the cable for purposes for which it is not intended - Do not use the cable to pull the plug out of the outlet. Protect the cable from

heat, oil and sharp edges.

Page 5: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

9. Take care of your tools - Keep your compressor clean in order to work well and safely. - Follow the maintenance instructions. - Check the connection cable of the electric tool regularly and have it replaced by

a recognised specialist when damaged. - Check extension cables regularly and replace them when damaged.

10. Pull the plug out of the outlet - During non-use of the electric tool or prior to maintenance and when replacing

tools such as saw blades, bits, milling heads. 11. Avoid inadvertent starting

- Make sure that the switch is switched off when plugging the plug into an outlet. 12. Use extension cables for outdoors

- Only use approved and appropriately identified extension cables for use outdoors.

- Only use cable reels in the unrolled state. 13. Remain attentive

- Pay attention to what you are doing. Remain sensible when working. Do not use the electric tool when you are distracted.

14. Check the electric tool for potential damage - Protective devices and other parts must be carefully inspected to ensure that

they are fault-free and function as intended prior to continued use of the electric tool.

- Check whether the moving parts function faultlessly and do not jam or whether parts are damaged.

- All parts must be correctly mounted and all conditions must be fulfilled to ensure fault-free operation of the electric tool.

- Damaged protective devices and parts must be properly repaired or replaced by a recognised workshop, insofar as nothing different is specified in the operating manual.

- Damaged switches must be replaced at a customer service workshop. - Do not use any faulty or damaged connection cables. - Do not use any electric tool on which the switch cannot be switched on and off.

15. Have your electric tool repaired by a qualified electrician - This electric tool conforms to the applicable safety regulations. Repairs may

only be performed by an electrician using original spare parts. Otherwise accidents can occur.

16. Important! - For your own safety you must only use the accessories and additional units

listed in the operating instructions or recommended or specified by the manufacturer. The use of mounted tools or accessories other than those recommended in the operating instructions or catalog may place your personal safety at risk.

Page 6: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

17. Noise - Wear ear muffs when you use the compressor.

18. Replacing the power cable - To prevent hazards, leave the replacement of damaged power cables strictly to

the manufacturer or a qualified electrician. There is a risk of electric shock! 19. Inflating tires

- Directly after inflating tires, check the pressure with a suitable pressure gauge, for example at your filling station.

20. Roadworthy compressors for building site operations - Make sure that all lines and fittings are suitable for the maximum permissible

operating pressure of the compressor. 21. Place of installation

- Set up the compressor on an even surface.

Additional safety instructions Safety instructions for working with compressed air and blasting guns

The compressor pump and lines can become very hot during operation. Touching these parts will burn you.

The air which is sucked in by the compressor must be kept free of impurities that could cause fires or explosions in the compressor pump.

When releasing the hose coupling, hold the hose coupling piece with your hand. This way, you can protect yourself against injury from the rebounding hose.

Wear safety goggles when working with the blowout pistol. Foreign bodies or blown off parts can easily cause injuries.

Do not blow at people with the blow-out pistol and do not clean clothes while being worn. Risk of injury!

Safety information for paint spraying

Do not process any paints or solvents with a flash point below 55° C. There is a risk of explosion!

Do not heat up paints or solvents. There is a risk of explosion!

If hazardous liquids are processed, wear protective filter units (face guards). Also, adhere to the safety information provided by the manufacturers of such liquids.

The details and designations of the Ordinance on Hazardous Substances, which are displayed on the outer packaging of the processed material, must be observed.

Additional protective measures are to be undertaken if necessary, particularly the wearing of suitable clothing and masks.

Do not smoke during the spraying process and/or in the work area. There is a risk of explosion! Paint vapors are easily combustible.

Never set up or operate the equipment in the vicinity of a fire place, open lights or sparking machines.

Page 7: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Do not store or eat food and drink in the work area. Paint vapors are harmful to your health.

The work area must exceed 30 m3 and sufficient ventilation must be ensured during spraying and drying. Do not spray against the wind. Always adhere to the regulations of the local police authority when spraying combustible or hazardous materials.

Do not process media such as white spirit, butyl alcohol and methylene chloride with the PVC pressure hose. These media will destroy the pressure hose.

Operating pressure vessels

You must keep your pressure vessel in good working order, operate the vessel correctly, monitor the vessel,carry out necessary maintenance and repair work immediately and meet the relevant safety precautions.

The supervisory authority may enforce essential control measures in individual cases.

A pressure vessel is not allowed to be used if it has faults or deficiencies that can endanger workers or third parties.

Check the pressure vessel for signs of rust and damage each time before using. Do not use the compressor with a damaged or rusty pressure vessel. If you discover any damage, then please contact the customer service workshop.

Instructions for using pressure vessels

The pressurized container is intended only for the storage of compressed air and is intended for static use in a horizontal position. It can be used in accordance with the operating pressure and temperature, which is visible on the plate of the pressure vessel and described in the technical data and further instructions.

Welding and heating the pressure vessel is prohibited!

In the high pressure vessel itself, safety and control instruments (safety valve, manometer) are installed, whose operations and use are described in the following instructions.

The maximum pressure is given in the technical data and the pressure vessel itself.

Instructions for maintaining pressure vessel

Before any intervention or maintenance of the pressurized container - it is necessary to release the air from the container and close the air flow into the vessel.

Welding and heating the pressure vessel is prohibited!

Periodically check the thickness of the sheet (cover and bottom);

The thickness of the shell should never be less than 2 mm

The bottom thickness should never be less than 2 mm

The permissible corrosion rate of 0.5 mm was taken into account in the container construction

Page 8: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Main components for: Technoworker MV 50 L and Technoworker MV 100 L

1. Compressor main handle 2. Pressure switch 3. Outlet valve 4. Pressure regulator 5. Pressure gauge 6. Non - Return valve 7. Drain Cock 8. Wheel 9. Discharge Pipe 10. Air Tank 11. Start button 12. Plastic cover The only difference between models is in volume of the pressure vessels.

1

2

3 4

5

6

7

9

8

10

11

12

Page 9: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Technical characteristics

Model: Technoworker MV 50 L Rated voltage : 230 V ~,50Hz Rated power: 2.2 kW Max. rotational shaft speed: 2850 /min Max. allowable working pressure: 8 bar (restart pressure 6 bar) Pressure vessel volume: 50 L Weight: 38 kg Noise: LpA = 85 dB(A), LwA = 97 dB(A), KpA = 3 dB(A) Max. operating temperature T max +100°C Min. operating temperature T min - 10°C Air Displacement 316 L/min Pressure tank OD 305 Dimensions (cm) 76x42.5x71 cm Protection type IP 20 Max. altitude (above mean sea level)

≤ 1000 m

Theoretic flow 320 l/min

Model: Technoworker MV 100 L

Rated voltage : 230 V ~,50Hz Rated power: 2.2 kW Max. rotational shaft speed: 2850 /min Max. allowable working pressure: 8 bar (restart pressure 6 bar) Pressure vessel volume: 100 L Weight: 52 kg Noise: LpA = 85 dB(A), LwA = 97 dB(A), KpA = 3 dB(A) Max. operating temperature T max +100°C Min. operating temperature T min - 10°C Air Displacement 180 L/min Pressure tank OD 407 Dimensions (cm) 86x45x79 cm Protection type IP 20 Max. altitude (above mean sea level)

≤ 1000 m

Theoretic flow 320 l/min

Wear hearing protection. The effects of noise can cause a loss of hearing.

Page 10: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Before starting the equipment Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.

Check the equipment for damage which may have occurred in transit. Report any damage immediately to the transport company which was used to deliver the compressor.

Install the compressor near the point of consumption.

Avoid long air lines and supply lines (extension cables).

Make sure that the intake air is dry and dustfree.

Do not install the compressor in a damp or wet room.

The compressor may only be used in suitable rooms (with good ventilation and an ambient temperature from +5 °C to 40 °C). There must be no dust, acids, vapors, explosive gases or inflammable gases in the room.

The compressor is designed to be used in dry rooms. It is prohibited to use the compressor in areas where work is conducted with sprayed water.

The oil level in the compressor pump has to be checked before putting the equipment into operation.

Electrical connection The electrical motor installed is connected and ready for operation. The connection complies with the applicable VDE and DIN provisions. The customer‘s mains connection as well as the extension cable used must also comply with these regulations.

Damaged electrical connection cable The insulation on electrical connection cables is often damaged. This may have the following causes:

Passage points, where connection cables are passed through windows or doors.

Kinks where the connection cable has been improperly fastened or routed.

Places where the connection cables have been cut due to being driven over.

Insulation damage due to being ripped out of the wall outlet.

Cracks due to the insulation ageing. Such damaged electrical connection cables must not be used and are life-threatening due to the insulation damage. Check the electrical connection cables for damage regularly. Make sure that the connection cable does not hang on the power network during the inspection. Electrical connection cables must comply with the applicable VDE and DIN provisions. The printing of the type designation on the connection cable is mandatory.

Page 11: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Assembly Handle grip assembly Insert bolt and washer on tank to fasten the wheels and rubber feet, (See Figure 1.) Air filter assembly Fit air filter on cylinder head, (See Figure 2.)

Oil Add air compressor oil from breath hole, to max line on oil lever (See Figure 3.) Breathing pipe assembly Fit the breathing pipe as shown in (See Figure 4.)

Page 12: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Installation Location It is extremely important to install the compressor in a clean, well ventilated area where the surrounding air temperature will not be high than 40°C. A minimum distance of 1m between the compressor and objects is required because objects could obstruct airflow.

Caution! Do not locate the air inlet of compressor near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the motor. Electrical installation

Warning!

All wiring and electrical connections should be performed by a qualified electrician. Installation must be in accordance with local codes and national electrical codes.

Caution! Never use an extension power cord with this product. Use additional air hose instead of an extension power cord to avoid power loss and permanent motor damage; Use of an extension power cord voids the warranty.

Grounding instructions This product is for use on a nominal 230 volt circuit and has a grounding plug. Make sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Danger! Improper use of grounding plug can result in a possible risk of electrical shock!

Page 13: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Danger!

Do not use a grounding adapter with this product! If repair or replacement of power cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire.

Danger!

Never connect green (or green and yellow) wire to a live terminal. Check with a qualified electrician or service man if grounding instructions not completely understood or in doubt as to whether product is properly grounded. Never modify the plug receptacle privately; if there are not fitting outlet, make

proper outlet installed by a qualified electrician.

Warning! Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be rated for at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for this minimum. Use a slow blow fuse or a circuit breaker.

Caution!

Overheating, short circuiting and fire damage will result from inadequate wiring. NOTE: 230 volt, 5 amp units can be operated on a 230 volt circuit under the following conditions:

No other electrical appliances or lights are connected to the same branch circuit.

Voltage supply is normal.

Circuit is equipped with a 5 amp circuit breaker or a 15 amp slow blow fuse. If these conditions cannot be met or if disconnection of current protection device occurs, it may be necessary to operate compressor from a 230 volt, 5 amp circuits.

Page 14: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Operation Pressure Switch Auto/Off Switch-In the “AUTO” position, the compressor shuts off automatically when tank pressure reaches the maximum preset pressure (0.8Mpa) and runs automatically when tank pressure reaches the minimum preset pressure (about 0.6Mpa). In the “OFF” position, the compressor will not operate. This switch should be in the “OFF” position when connecting or disconnecting the power cord from the electrical outlet or when changing air tools. Regulator The regulator uses to adjust the pressure of outlet to fitting air-power tools. Safety Valve It releases compressed air automatically when the pressure in the tank exceeds allowing pressure. Discharge Pipe Discharge pipe connects the pump head and checks valve. It is hot when the compressor is running. To avoid grievous burn, never touch discharge Pipe. Check Valve Check valve is a one-way valve, allowing compressed air go ahead to the tank, but prevents compressed air in the tank back to the pump. Handle and wheels Designed in order to move the compressor easily.

Warning!

Never use the handle on wheeled units to lift the unit completely off the ground. Drain Valve This valve is located at the bottom of the tank. Used to exhaust water from the tank. Make sure the gauge pressure of the tank is below 1 Bar, open the drain valve to exhaust water from tank, close it tightly. This action should be done every week.

Page 15: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Add oil Air compressor oil is suggested to use. Keep the oil’s level in the red cycle of oil glass.

SAE30 oil is suggested to use. Break-in procedure

Caution!

Do not attach air chuck or other tools to the outlet until unit have been checked and start procedure has been completed.

IMPORTANT: Do not operate compressor before reading instructions, otherwise damage may result. 1. Turn regulator fully clockwise to open airflow. 2. Turn switch to OFF position and plug in power cord. 3. Turn switch to AUTO position and run unit for 30 minutes to run the pump parts. 4. Turn regulator knob fully counterclockwise. Compressor will build to maximum

preset pressure and shut off. 5. Turn regulator knob clockwise to bleed

off air. Compressor will restart at a preset pressure (about 6 bar).

6. Turn regulator knob counterclockwise to shut off the air and turn switch to off position.

Page 16: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

7. Attach chuck or other tool to outside. Open the pressure switch to AUTO position, the compressor starts work and pumps air into the tank. It shuts off automatically when unit reaches its maximum preset pressure. In the OFF position, the pressure switch cannot function and the compressor will not operate. Make sure switch is in OFF position when connecting or disconnecting power cord to electrical receptacle.

Moisture in compressed air Moisture in the air will change to water when air is compressed or temperature is drop. When humidity is high or when a compressor is in continuous use for a long time, water will collect in the tank. If you use a paint spray or sandblast gun, moisture will be carried from the tank through the hose, and out of the gun as water mixed with the spray material. IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to case and clog the gun rendering it ineffective. A dry filter in the air line, located nearby the gun as possible, will help eliminate this moisture. Safety valve

Warning!

Do not remove or attempt to adjust the safety valve! Safety valve should be checked under pressure occasionally by pulling the ring by hand. If air leakage after ring has been released, or valve is stuck and cannot be actuated by ring, it MUST be replaced.

Regulator 1. Regulator adjusts air pressure to fit an air-operated tool or paint spray gun. 2. Adjust outlet air pressure by turn the knob Pressure gauge There are 1 or 2 gauges on this type of compressor, one shows pressure in tank and another one (if there are 2 gauges) shows outlet’s pressure after regulator.

Page 17: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Thermal overload protector

Caution! This compressor is equipped with an automatic reset thermal overload protector, which will shut off motor if it becomes overheated. If thermal overload protector shuts motor OFF frequently, look for the following causes. 1. Low voltage. 2. Clogged air filter. 3. Lack of proper ventilation.

Caution!

If the thermal overload protector is actuated, the motor must be allowed to cool down before start-up is possible. The motor will automatically restart without warning if left plugged into electrical outlet and unit is turned on.

Cleaning, maintenance, and storage

Important! Pull out the power plug before doing any cleaning and maintenance work on the equipment. Risk of injury from electric shock!

Important! Wait until the equipment has cooled down completely! Risk of burns!

Important!

Always depressurize the equipment before carrying out any cleaning and maintenance work! Risk of injury! Cleaning

Keep the equipment free of dirt and dust as far as possible. Wipe the equipment with a clean cloth or blow it down with compressed air at low pressure.

We recommend that you clean the equipment immediately after you use it.

Clean the equipment regularly with a damp cloth and some soft soap. Do not use cleaning agents or solvents; these may be aggressive to the plastic parts in the equipment. Ensure that no water can get into the interior of the equipment.

Page 18: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

You must disconnect the hose and any spraying tools from the compressor before cleaning. Do not clean the compressor with water, solvents or etc.

Maintenance work on the pressure vessel

Daily 1. Check oil level before each use. 2. Drain the condensation from the air receiver. 3. Check for air leaks.

Weekly 1. Remove air filter element and clean or replace as required.

Monthly 1. Inspect non-return valve (clean or replace as required) Caution: ensure that air the tank is empty for this operation. 2. Manually test the safety valve by pulling the ring. Three Monthly 1. Change Oil 2. Tighten cylinder head bolts. 3. Clean and check valve assembly, replace gaskets/ valves if worn or damaged. Recommend compressor oil use SAE 30 for temperatures over 10 ℃ and use SAE 10 below 10 ℃.

Important! To ensure a long service life of the pressure vessel, drain off the condensed water by opening the drain valve each time after using. Open the drain screw so that all the condensed water can run out of the pressure vessel. Then close the drain screw again. Check the pressure vessel for signs of rust and damage each time before using. Do not use the compressor with a damaged or rusty pressure vessel. If you discover any damage, then please contact the customer service workshop.

Important! The condensed water from the pressure vessel will contain residual oil. Dispose of the condensed water in an environmentally compatible manner at a suitable collection point.

Page 19: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Safety valve The safety valve has been set for the highest permitted pressure of the pressure vessel. It is prohibited to adjust the safety valve or remove its seal. Actuate the safety valve from time to time to ensure that it works when required. Pull the ring with sufficient force until you can hear the compressed air being released. Then release the ring again. Storage

Important!

Pull out the mains plug and ventilate the equipment and all connected pneumatic tools. Store the compressor only in a dry location. Switch off the compressor and make sure that it is secured in such a way that it cannot be started up again by any unauthorized person. Always store upright, never tilted! Oil may leak out!

Disposal and recycling

This symbol indicates that this product should not be disposed of with general household waste. This applies throughout the entire EU. In order to prevent any harm to the environment or health hazards caused by incorrect waste disposal, the product must be handed in for recycling so that the material can be disposed of in a responsible manner. When recycling your product, take it to your local collection facility or contact the place of purchase. They will ensure that the product is disposed of in an environmentally sound manner.

The equipment is supplied in packaging to prevent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and plastic. Defective components must be disposed of as special waste. Ask your dealer or your local council.

Page 20: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Troubleshooting chart

Symptom Possible Cause (s) Corrective Action

Compressor can not start/restart

1. No electrical power, Wire connector loose;

2. Fuse shut off; 3. Circuit break; 4. Thermal overload switch

open; 5. Pressure switch ineffective;

1. Make sure machine connects to power, Check connector and motor overload switch.

2. Change fuse. 3. Reset circuit breaker, check for the low

voltage conditions. 4. Turn air compressor off, wait until the

motor is cool and overload switch close, then running again.

5. Replace Pressure switch.

Motor stalls or runs slowly

1. Voltage is too low 2. Wrong lubrication or lack

lubrication 3. Low power due to Poor

connection. 4. Motor short circuit 5. Check valve is blocked

1. Check the low voltage conditions. 2. See lubrication section in instruction

manual 3. Check connecters, eliminate extension

cork if used, check circuit with voltmeter

4. Replace motor. Find a certified electrician check the motor and wiring. Proceed with his or her recommendations.

5. Disassemble check valve to check if it is blocked, and replace it.

DANGER! Never disassemble check valve under pressure. release tank firstly

Fuses blow /circuit breaker trips repeatedly. CAUTION! Never use an extension cord with this product

1. Incorrect size fuse, circuit overloaded.

2. Defective check valve or unloaded

1. Check for proper fuse, use time-delay fuse. Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 2. Replace or repair. DANGER! Never disassemble check valve under pressure. release tank firstly

Thermal overload protector cuts out repeatedly

1. Low voltage 2. Clogged air filter 3. Lack of proper

ventilation/room temperature too high

4. Check valve malfunction 5. Compressor valves failed

1. Eliminate extension cord, check with voltmeter

2. Clean filter (see Maintenance section) 3. Move compressor to well ventilated

area 4. Replace 5. Replace valve assembly DANGER! Never disassemble check valve under pressure. release tank

Page 21: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

firstly

Knocks, rattles, excessive vibration

1. Loose bolts, tank not level 2. Defective bearing on

eccentric or motor shaft 3. Cylinder or piston ring is

scored

1. Tighten bolts, shim tank to level position

2. Replace 3. Replace or repair as necessary

Tank pressure drops when compressor shuts off

1. Loose drain cock 2. Check valve leaking 3. Loose connections at

pressure switch or regulator

1. Tighten 2. Disassemble check valve assembly,

clean or replace 3. Check all connections with soap and

water solution and tighten

Compressor runs continuously and air output is lower than normal/low discharge pressure

1. Excessive air usage, compressor too small

2. Clogged intake filter 3. Air leaks in piping (on

machine or in outside system)

4. Broken inlet valves 5. Piston ring worn

1. Decrease usage or purchase unit with higher air delivery (SCFM)

2. Clean or replace 3. Replace leaking components or tighten

as necessary 4. Replace compressor valves 5. Replace piston and cylinder

Excessive moisture in discharge air

1. Excessive water in tank 2. High humidity

1. Drain tank after every use. 2. Move to area of less humidity; drain

air tank more often in humid weather and use air line filter.

NOTE: Water condensation is not caused by compressor malfunction

Compressor runs continuously and safety valve opens as pressure rises

1. Defective pressure switch 2. Defective safety valve

1. Replace switch 2. Replace safety valve with genuine

replacement part

Excessive starting and stopping (auto start)

Excessive condensation in tank

Drain more often

Air leaking from release valve on pressure switch

Check valve stuck in an open position

Remove and replace check valve DANGER! Never disassemble check valve under pressure. release tank firstly

Page 22: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Instructions for use and maintenance of pressure vessels

Pressure vessels models Type

Description OD305 OD407

Construction for pressure P 8.8 bar / 880 kpa

Maximum allowed pressure PS 8.0 bar / 800 kpa

Operating temperature Tmin ~ Tmax

-10 ℃ ~ +100 ℃

The volume of vessel V (L) 50~80 L 100~200 L

Allowed corrosion c 0.5 mm

Wall thickness 2.0 mm 3.0 mm

Considered standards and directives SPV 2014/29/EU & EN286-1:1998+A1:2002

1. The operating pressure must not exceed the maximum permissible pressure. The user is responsible for the problems arising from the exceeding of the maximum allowed pressure.

2. Pressure vessel is used for oil-lubricated compressors. 3. The pressure vessel is an important part of the air compressor. The air compressor can’t

function - until all necessary components are plugged in, especially the safety components. The safety valve must be tested before the compressor can function normally.

4. Pressurized container must have at least one safety valve. Prior to installation, the safety valve must be checked by an authorized organization. During the lifetime of the pressure vessel, the safety valve must be inspected at least once a year to prevent corrosion.

5. In a pressure bottle, gauge must be placed. The gauge must have a measuring range of at least 1.5 to 3 times the projected pressure p.

6. The user must have a record of safety information for a pressure vessel, including a regular maintenance list. If it comes to an unusual event, it must report it and inspect an expert who has special devices for checking the pressure vessel.

7. The lifetime of the pressure vessel is at most 7 years. When this age is reached, the pressure vessel must no longer be used unless it is inspected by the authorized body with special equipment for checking pressure vessels and allows for further use.

8. Pressurized bottle must be placed on a flat surface. This will prevent the welding of the welded joints due to the additional vibration of the pressure receptacle.

9. Pressurized bottle should not be hit or pressed with any force. 10. Pressurized bottle should not be in contact with corrosive substances or work in a

corrosive environment. 11. The water drain valve must be opened regularly to remove water from the tank and

prevent its corrosion. 12. Pressurized bottle must not be heated, welded or otherwise repaired, especially on the

parts of the pressure vessel.

Page 23: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …

Declaration of conformity

According to the Machinery Directive 2006/42/EC of 17 May 2006, Annex II A

Olisgrup SRL R-nul Straseni, s. Zubresti, Republica Moldova Tel: + 373 68 161 513

Product: Air compressor Models: Technoworker MV 50 L / Technoworker MV 100 L

We declare under full responsibility that the above mentioned product is designed and manufactured in accordance with: Directive 2006/42/EC on safety of machinery Directive 2009/105/EC on simple pressure vessels Directive 2014/30/EU of electromagnetic compatibility Directive 2011/65/EU, 2012/50/EU, 2012/51/EU on the restriction of use of certain hazardous substances in electrical and electronic equipment (RoHS) Directive 2000/14/EC, 2005/88/EC on noise directive The notified body accordance with Directive 2000/14/EC, 2005/88/EC, Intertek Testing Services Shanghai test report no. 160800521HZH-001

the measured sound power level LwA 95.46 dB(A)

the guaranteed sound power level LwA,g = 97 dB(A)

The harmonized and other standards: EN 55014-1:2006+A1:2009+A2:2011, EN 55014-2:2015, EN 61000-3-2:2014 EN 61000-3-3:2013 EN 1012-1:2010 EN 60204-1:2006/+A1:2009

Certification Body under the Directive 2014/29/EU: APRAGAZ Belgium CE0029 Certificate Nº 16/CN/4025-0 Rev.0, dat. 12.12. 2016 P11369/SPV01 Identification mark of pressure bottle series MV 50 L: OD 305 Identification mark of pressure bottle series MV 100 L: OD 407

The responsible person authorized to compile the technical documentation: Sirghi Oleg at the company Olisgrup SRL, R-nul Straseni, s. Zubresti, Republica Moldova

Sirghi Oleg The person authorized to make a statement on behalf of the manufacturer

Place / date: Moldova, 14.10.2019

Page 24: AIR COMPRESSOR Technoworker MV 50 L ... - Amazon Web …