Page 1OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

AHM-1C HOPPERMOUNT DRYER

OPERATING MANUAL

Page 2 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

DRI-AIR INDUSTRIES, INC.16 THOMPSON ROADP.O. BOX 1020EAST WINDSOR, CT 06088-1020

Tel. (860) 627-5110FAX (860) 623-4477Internet http://www.dri-air.come-mail: [email protected]

Page 3OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

CONTENTS

DRYER DESCRIPTION Pg 4

AIR FLOW SCHEMATIC Pg 7

DRYER CYCLE DIAGRAM Pg 8

INSTALLATION PROCEDURE Pg 9

START-UP PROCEDURE Pg 11

ALARMS Pg 12

ROUTINE MAINTENANCE Pg 13

BASIC TROUBLE-SHOOTING Pg 15

DETAILED TROUBLE-SHOOTING Pg 16

ZONE VALVE TROUBLE-SHOOTING Pg 18

CONTROLS TROUBLE-SHOOTING Pg 18

PARTS LIST Pg 19

ELECTRICAL SCHEMATIC 110V Appendix85257

ELECTRICAL SCHEMATIC 220V Appendix85258

Page 4 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

The AHM-1 dryer is a fully assembled dryer andhopper combination that can be mounted directlyto the feed throat of small molding machines. It isideal where floor space is limited and materialchanges are infrequent. This dryer model will drymost materials at throughputs up to 10 pounds perhour.

The AHM-1 utilizes our ARID-X dual desiccantbed design that provides a constant supply of dryair to the attached 30-pound material hopper. Whileone bed is removing moisture from the process airstream, the other bed is regenerated by heating thedesiccant to a high temperature. Once theregenerated bed cools down, the zone valveswitches the air stream and the newly regeneratedbed is now used for drying the process air. Thesaturated bed is then regenerated, repeating thecycle. This cycle is described below and depictedin the schematics on pages 7 and 8.

The airflow design of the ARID-X dryers makesthe regeneration cycle more efficient because weutilize a small amount of the desiccated processair rather than ambient air to regenerate thedesiccant bed. This reduces the impact of thehigh moisture content of the ambient air, whichwould contaminate the desiccant bed, and allowsthe dryer to attain a lower dew point. Please seefigure on page 7.

HP4-X Design

Our patented HP4-X design incorporates 4desiccant beds where two are stacked, one overthe other. This nearly doubles the amount ofdesiccant available for drying the process airstream, and because of the tower design, thedryer is able to regenerate the desiccant in thesame time as our ARID-X series. This allows

DRYERDESCRIPTION

Page 5OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

the dryer to operate in very high humidityconditions without affecting the process air dewpoint. In fact, this design produces dew pointlevels of –40° to -80° C for faster more completedrying of your material. Please see Airflow andRegeneration Cycle diagrams on the followingpages.

Hopper Design

Our “all stainless” hopper design utilizes astainless steel inner shell surrounded by astainless steel jacketed insulation layer. Theeasily removable stainless steel spreader conepromotes proper material flow to ensure that thematerial is dried efficiently and no dried materialis left at the hopper bottom that needs to be fedout prior to operating. You must ensure that yourhopper is kept filled, to ensure that you havesufficient time to dry the material.

Dryer Controls

The AHM-1 dryer is supplied with a factoryprogrammed ELC Control Module and DigitalTemperature Controller.

ELC Control Module

The ELC Control Module controls theregeneration cycle described above. It has beenfactory programmed and does not require anyadditional input by the operator. The module willautomatically monitor and control the dryer’soperation by controlling the regeneration cycle,heaters and alarms.

Digital Temperature Controller

The Digital Controller works in tandem with theELC Control Module to monitor and controlprocess air temperature. Its touch pad allows youto input the dryers operational settings and alarm

DRYER DESCRIPTION(Cont’d)

Page 6 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

points. These are explained in more detail laterin this manual.

Dri-Air Electric Rotary Zone Valve

The AHM-1 utilizes our exclusive electric rotaryvalve technology, which helps make this dryertruely portable and low maintenance. As thevalve does not need compressed air to operate, itis far more reliable than valves that depend onclean compressed air at a constant pressure.

The valve is designed to be practicallymaintenance free, as the seals are self seating andare designed to provide years of trouble freeservice. The electric controls are easilyaccessable for trouble-shooting, and are equippedwith lights to indicate the zone position of thevalve.

DRYER DESCRIPTION(Cont’d)

Page 7OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

FROMMATERIALHOPPER

FILTERVORTEXBLOWER

4-WAY ZONE VALVE

VENT

TO HOPPER

HEATERSREGENERATION

AIR FLOW SCHEMATIC FOR ARID-X 10/AHM-1 DRYER

PROCESS HEATER

SAFETY THERMAL

AIRAHM1

LOWER

REGENERATIONHEATERS

UPPER

Page 8 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

Dry

erC

ycle

Dia

gram

Des

ican

tBed

s

Page 9OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

Press Mounting

Each AHM-1 dryer hopper is supplied with a 6 x 6inch mounting flange with a slide gate. The flangeis configured with two rectangular 3.25 x 5 inchbolt hole patterns, rotated 90° from each other toallow for the dryer to be oriented in any quadrant.

Depending on the user’s requirements, the dryer issupplied with a Mounting Adapter with flangedimensions of either 6”x 6” to 4”x 4” or 6”x 6” to6”x 6”. Please see below. The Mounting Adapter’supper 6”x 6” hopper flange is pre-drilled with theabove mentioned bolt hole pattern.

6x6” to 6x6” 6x6” to 4x4”

To install the adapter to the molding machine, drillthe adapter’s bottom mounting flange with holescorresponding to the bolt hole pattern on themolding machine’s feed throat mounting flange.Bolt the adapter to the feed throat, using grade 5bolts or better. CAUTION: Please note theorientation of the adapter drain port prior to drillingand attaching the adapter. Position this port to bestfacilitate the draining of material from the hopper.

To install the dryer, utilize a hoist or other suitablemeans (The unit weighs 95 pounds when empty.)to lift the unit and place it on the mounting adapter.For ease of use, orient the unit with the hopper doorfacing the operator. Bolt the dryer in place usingthe bolts provided.

INSTALLATIONPROCEDURE

Page 10 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

Electrical Connection

The AHM-1 dryer is available in 110 or 220 volt,single-phase models. The 110 volt model issupplied with a power cord and grounded threeprong plug, while the 220 volt model requires anappropriately grounded plug, suitable to the user’spower supply to be attached to the power cord.

To connect the dryer to electrical power, plug inthe cord to any suitably grounded power source.With all units being single phase, blower rotationwill be correct.

Post-Installation Inspection

Prior to starting the dryer, inspect the unit to ensurethe following:

1. All hose couplings are tight and secure.2. Hoses are not crushed or obstructed.3. Process Air Thermocouple is connected.4. Inside of hopper is clean before filling with

material

INSTALLATIONPROCEDURE

(Cont’d)

Page 11OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

STARTUP PROCEDURE

CAUTION: Only personnel qualified to operatethis dryer should start and run this dryer.

Dryer Controls

Main Power - The rocker switch located on theleft side of the dryer face panel controls allpower to the dryer. It functions as the maincircuit breaker for the dryer and in emergencies,will cut all power to the unit.

Dryer Start-up

To initiate dryer start-up, press the rocker switchon the unit’s face panel. The Rocker Switchshould illuminate; indicating power is suppliedto the unit. The dryer is now operating, followthe instructions below to set the process airtemperature or to shut the dryer off.

1. Rocker Switch POWER ON light indicates there ispower to the controls, heaters, valve and blower.2. The dryer is now ready for setting the Process Airtemperature. Follow instructions in next section.3. The AMBER TEMPERATURE ALARM light willilluminate if an alarm condition arises. Further diagnosticsrequired. See sections on Alarms and Trouble-shooting.4. To stop dryer press the Rocker Switch to the OFFposition.

To Set Process Air Temperature:

Using the Digital Temperature Controller:

1. Press SEL button on the controller toenable the red Temperature Set display(labeled SV) to be altered.

2. Press the up arrow key ↑ key toincrease the set point or the down arrow↓ key to decrease the setting until the

DRYER OPERATION

CONTROL PANEL

Digital Controller

Page 12 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

desired process air set point is displayed.

3. Press the SEL key again to enter thenew temperature setting.

CAUTION: Do not operate this dryer below 140degrees F (60 deg. C) or above 350 degrees F(177 deg. C).

The High Temp Alarm condition discussedbelow will initiate a “Dryer Shutdown” that cutspower to the blower, digital controller and ELCoutput relays. See Trouble-Shooting section ofthis manual.

Process Air Temperature Alarms

The ELC/Digital Control system ispreprogrammed with alarm set points that willshut the dryer down and activate theTEMPERATURE ALARM light on the dryercontrol panel and the ALM1 light on the digitalcontroller.

The alarm will be activated if either the processair temperature fails to reach the set point withinthe alloted time period or the temperatureexceeds the high limit. The HIGH TEMPALARM light will illuminate for bothconditions.

Thermocouple Failure Alarm

If a failure is detected with the Process AirThermocouple, the upper Process AirTemperature display (labeled PV) on the DigitalController will flash and display 0000. Thisalarm will be displayed if the thermocouple isnot connected or is faulty.

ALARMS

Page 13OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

When operating this dryer please follow theprocedures detailed below:

Routine Operation

The dryer should be operated in a dryenvironment at ambient temperatures between 50and 110 degrees F (10-44 deg. C). The unitshould be situated so that the air hoses are notcrimped or restricted after connection with thematerial hopper and the controls are easilyaccessible to the operator.

When moving the dryer allow the dryer to coolcompletely before handling. Recheck the hoseand thermocouple connections to ensure that theyare tight.

To shut the dryer down, press the OFF button onthe Control Panel and press the rocker switch tothe off position. Always unplug the unit whennot in operation.

Emergency Shutdown

In the event that a condition should arise thatrequires the operator to immediately halt thedryer’s operation, the operator can press therocker switch to the off position and the unit willshut down completely. Remove the power plugfrom the facilty outlet to cut all power from thedryer.

Hopper Maintenance

1. Always clean hopper, air inlet port anddiffuser basket prior to adding or changingmaterials.

2. Never over-fill the hopper. Material shouldnot obstruct the exhaust port at the top of thehopper.

ROUTINE OPERATION &MAINTENANCEPROCEDURES

Page 14 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

Filter maintenance

1. Open filter canister and clean filter elementon a daily basis.

2. Change filter cartridge every 6 months(Sooner if materials dried are dusty.).

Never operate dryer without filter element installed.

Dryer Cleaning

Always unplug the dryer before cleaning.

The dryer is supplied with a surface coating thatis easily cleaned and maintained by simplywiping the dryer with a moistened cloth or rag.Never clean the dryer with solvents or corrosiveliquids. Always allow the dryer to coolcompletely before cleaning.

Page 15OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

All maintenance and trouble-shooting should be performedby a qualified electrician and a trained operator.

Nearly all diagnostic procedures can be performed with avolt ohmmeter and an AC/DC Ammeter.

In the event that the dryer will not start or shuts down in analarm condition please take the following steps prior toother diagnostic steps.

1. Check the Power Circuit:a. Incoming power fuses (F1 & F2).b. Dryer fuse (F3). It has a blown fuse indicator

that lights up if the fuse is defective.c. Is POWER light in Rocker Switch

illuminated?d. Check heater’s continuity using a volt

ohmmeter.

2. Air Flow Circuit:a. Ensure Zone Valve is operating correctly and

is in proper zone position. See VALVETROUBLE SHOOTING.

b. Make sure that all hoses are connected, notcrushed, and free from obstructions.

c. Inspect filter and make sure cover is tight.

3. Control Circuit:a. Using the ELC LCD Output/Input

Enunciators as a guide for the status of thedryer regeneration cycle, check that all inputsare proper for the part of the regenerationcycle that the unit is in. See page 18.

4. Operating Conditions:a. Check the process temperature. It should not be

set below 140 °F (60 °C) because the unit willgo into high temp alarm.

TROUBLE-SHOOTING GUIDE

BASIC TROUBLE-SHOOTING

VALVE TROUBLESHOOTING

To determine proper ZONEPOSITION for valve, followprocedures detailed below:

1. Open front panel of dryer toview ELC’s LCD.2. Open Right Side Panel toview Valve Control Board.3. Note if enunciator under #4on ELC LCD is on, indicatingdryer is in Zone 2. If no enun-ciator is visible, the dryer is inZone 1.4. Note which Zone Light isilluminated on Valve ControlBoard. Light should correspondto ELC LCD.

Page 16 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

Rocker Switch light is not on. Unit will not start:

1. Check small fuse. The LED ill be lit if it isblown. Replace if necessary by opening thefuse holder and put new fuse into holder.

2. Check that incoming power to the unit is proper.3. Check safety snap disc with multi-meter.

(Should be normally closed)

HIGH TEMP ALARM light is illuminated. Unit willnot run:

This indicates that the process air temperaturehas; exceeded the high limit programmed intothe temperature controller, failed to reach theprocess air temperature set point, or there hasbeen a thermocouple failure. To determinewhich of the aforementioned conditions causedthe alarm, perform the procedure below.

Press Rocker Switch to OFF position and restart machineby moving switch to ON position. View what is displayedon the digital controller Process Air Temperature display.If it exceeds the set point an overtemp condition hasoccured. If it is below the set point, the dryer cannot reachthe set point. If 0000 is displayed, a thermocouple failurehas occured. Perform the following procedures for theindicated failure.

Depending on when the operator discovered thealarm, the dryer may restart if it had sufficienttime to cool down. If this happens simply allowthe dryer to operate until the alarm occurs andthen perform the above procedure.

Machine will not reach temperature:

1. If the Output Light (C1) on Digital Controlleris not lit.

A. Check position of the Process AirThermocouple. The probe tip should bein the middle of the hose.

B. Check Digital Controller - may befaulty.

DETAILED TROUBLE-SHOOTING

Page 17OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

2. If the Output Light (C1) on Digital Controlleris lit.

A. Check the solid-state relay on panel.B. Check airflow through process air hose.

Check the alarm limit first, by pressing andholding the SEL button on the temperaturecontroller until STBY is displayed. Then pressthe DOWN arrow key until AL1 is displayed inthe upper (PV) display. The setting displayed inthe lower (SV) display indicates the number ofdegrees over the set point that the alarm will beactuated. It is factory set to 50°F (30°C) andshould not be set below 30°F (16°C) or it willactuate too quickly.

If the temp exceeds the set point, check the following:

1. Remove the hose from the top of the hopperto check airflow. There should be airflow outof the hopper exhaust port and a vacuum onthe hose. If there is little or no flow, checkthe inlet hose.

2. Inspect the filter to make sure that it is cleanand not affecting the airflow.

3. Check the to see if the solid state relay hasfailed on by using a multi-meter on the outputto the heater. The relay has failed if there ispower to the heater when the Solid-staterelay’s input power is not activated.

If thermocouple has failed, check following:

1. Ensure thermocouple plug is securely insertedinto dryer outlet.

2. Check thermocouple continuity with multi-meter.

Page 18 OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

The Rotary Zone Valve is designed to providevery little flow restriction and no leakage. Itincorporates high temperature, self adjustingseals for years of trouble free service. Theelectrical controls are built into the end of thevalve and include position lights.

Trouble-shooting is easy. If the lights indicatingposition do not match the zone displayed on thecontrol panel, or there are no lights, the valve isnot working properly. See if the cam is actuatinga switch.

DO NOT PUT FINGERS INTO VALVE WITHPOWER ON

Check all electrical connections to make sure theyare tight.

Contact factory for a replacement valve P/N 83707with serial number of dryer.

ELC Control ModuleThe dryer control package includes a ELCcontroller that is programmed for the dryingcycle discussed previously. Each input/outputterminal on the Module has a correspondingenunciator displayed on the Module’s LCDdisplay that can be used for trouble-shooting. Innormal operation the LCD displays numbers 1 to6 with with a row of enunciators above thenumbers for the inputs and a row of enunciatorsbelow for the outputs. (See Reference Guide tothe left.) When the enunciator is displayed theinput or output is actuated. All ELC inputs/outputs are 120 volts AC.

Dryer Control PanelThe Control Panel for the dryer includes an ON/OFF Rocker switch that acts as the Main PowerSwitch and EMERGENCY STOP. When thisswitch is in the OFF position all power is cut tothe Controllers, Blower and Electric Valve.

TROUBLE-SHOOTINGROTARY ZONE VALVE

TROUBLE-SHOOTINGCONTROLS - ELC

REFERENCE GUIDELCD ENUNCIATORS

The following list details thecorresponding inputs & outputsto the numbered enunciatorsdisplayed on the ELC’s LCD.

UPPER ENUNCIATOR ROW

NO. INPUT# DESC. 1 I1 Main Power 2 I2 High Temp Alm3-6 Spare

LOWER ENUNCIATOR ROW

NO. OUTPUT# DESC. 1 Q1 Z1 Heaters 2 Q2 Z2 Heaters 3 Q3 Main Contactor 4 Q4 Zone Valve

Page 19OPERATING MANUAL - AHM-1C HOPPER MOUNT DRYERRevision 8/31/04

DRI-AIR INDUSTRIES, INC.

PART NUMBER DESCRIPTION

84231 FILTER CARTRIDGE83707 ZONE VALVE82125 BLOWER84054 THERMOCOUPLE85241 TEMP. CONTROLLER (FUJI)80082 DESICCANT 4 lb./MACHINE80221 THERMAL SWITCH (500°)85232 FUJI ELC CONTROL80857 2 POLE RELAY82496 1 POLE RELAY82303 SOLID STATE RELAY82035 .5A FUSE HOLDER83443 .5A FUSE84691 LARGE FUSE HOLDER80907 AMBER LIGHT83079 ROCKER SWITCH81942 7 DAY TIMER

84414 UPPER TOWER HEATER 110 v84412 LOWER TOWER HEATER 110v84409 PROCESS HEATER 110v83625 TRANSFORMER – 110v

83437 TRANSFORMER – 220v84413 UPPER TOWER HEATER 220v84411 LOWER TOWER HEATER 220v84410 PROCESS HEATER 220v

PARTS LIST: AHM-1

General

110v Dryer

220v Dryer