agilent technologies 16700b and 16702b logic analysis · pdf filemodel no. interface control...

Download Agilent Technologies 16700B and 16702B Logic Analysis · PDF fileModel No. Interface Control Measurement capability Timing and state analysis, pattern generation, oscilloscope 16700B

If you can't read please download the document

Upload: ngothu

Post on 06-Feb-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • Agilent Technologies 16700B and 16702B Logic Analysis Systems

  • 2

    Agilent Technologies 16700 Series logic analysissystems help design teamsovercome time-to-marketobstacles and meet toughengineering challengesfrombasic circuit board turn-on tovalidating signal integrity.

    With their wide variety ofmeasurement capabilities, the16700B and 16702B high-performance modular systemsenable you to rapidlyconsolidate data into meaningfulinsight while giving you the mostcomplete view of your systemsbehavior. And since accurateacquisition starts with probing,we also offer reliable,unobtrusive probes that make iteasy to connect your Agilentlogic analyzer to your systemunder test.

    As the innovator of logicanalysis, Agilent (formerlyHewlett-Packard) continuesto provide leading-edgesolutions that evolve withyour changing needs. Themodular form factor ofthe 16700 Series is thekey to their long-termvalue. You purchase onlythe capability you neednow, then expand as yourneeds evolve.

    Configuring these modularsystems is as easy as 1, 2, 3.Select your choice of productsthat will (1) Connect, (2) Acquire, and (3) View/Analyzethe data from your system undertest. For example, you canchoose the timing/state logicanalyzer modules, oscilloscopeand pattern generator modulesand data post-processing andprotocol tools that meet yourspecific needs.

    From basic board turn-on tosignal integrity validation

    Introduction

    www.agilent.com/find/la-systems

    Figure 1. The 16700B and16702B high-performancemodular systems enable youto rapidly consolidate datainto meaningful insight.

    Figure 2. The AgilentTechnologies 16700 Series logicanalysis systems help designteams meet tough engineeringchallengesfrom basic circuitboard turn-on to validatingsignal integrity.

    connect1 2 3acquire view & analyze

  • 3

    connect1 2 3acquire view & analyze

    The power and flexibility to provide themost complete view of system behavior

    Modular Systems

    Agilent Modular 16700 Series Logic Analysis System Mainframes

    Agilent Technologies modularlogic analysis systems providethe ultimate power and flexibilityto match your digital systemdebug needs. Configure a logicanalysis system that provides acomplete view of your systems

    behavior. Select the measure-ment modules, probing andanalysis options suited for yourspecific application that resultsin efficient debug and validation.

    Configure a basic or multi-framesystem suited to your needs

    Protect your investment with asystem that adapts to multiple,current and future projects

    View cross-domain measurements,correlated in time

    Easily master powerful logic analysis capabilities with the16702Bs touch-screen interface

    Model No.

    Interface Control

    Measurementcapability

    Timing and state analysis, pattern generation, oscilloscope

    16700B and 16702BOptions

    Option 001 Add 17-inch 1280 x 1024 monitor Option 003 256 MB system RAM, 4 MB video RAM Option 008 18 GB external data drive Option 009 external removable hard drive Option 012 multiframe module

    16702B Modular System

    Touch screen, knobs, and dedicated hot keys (mouse, keyboard

    also provided)

    16700B Modular System

    Mouse, keyboard

    16701B Expansion Frame

    N/A

    Number of Slots 5 5 5

    Display Type(s) andResolution

    Internal: 12.1 inch color touchscreen, 800 x 600

    External: Supports resolutions up to1600 x 1200 with option 003.

    Requires external display.Supports up to 1280 x 1024

    standard, 1600 x 1200 requiresoption 003.

    N/A

    Data Viewing Types

    Standard: Waveform, listing, histogram, chart, compare

    Module specific: eye diagrams

    Optional software tool sets: source code, protocol decode,serial analysis, system performance analysis (SPA)

    N/A

    Connectivity

    Time-correlate logic analyzer trace to external Infiniium 54800 Series oscilloscope.Automated de-skew and tracking of markers.

    Offline analysis, e-mail on trigger, individual user logins for network security

    Remote programmability via Microsoft Active X/COM for PCs and TCP/IPsocket based ASCII commands for UNIX .

    Remote access of the analyzer from a web browser (web-enabled).

    File transfer and storage via mapped shares or mounted drives (Windows and UNIX)

    N/A

  • 4

    www.agilent.com/find/la-systems

    Logic Analyzer Probing Solutions

    Probing Method(Application)

    Signal Type Max. DataRate

    Min. SignalAmplitude

    Model Number

    Channels Logic AnalyzerCompatibility

    Equivalent LoadCapacitance

    ConnectorlessProbingQuick connectionto many signals ina small footprintwithout requiringa header designedinto the target

    Differential or single-endedclock, Single-ended data

    Differential or single-ended clock,

    Differential or single-ended data

    Single-ended clock, Single-ended data

    > 2.5 Gb/s

    250 mV p-p

    Vmax Vmin200 mV

    500 mVp-p

    E5390A(Soft touch)

    E5387A(Soft touch)

    E5394A

    (Soft touch)

    34

    17

    34

    90-pin cableconnector

    40-pin cable

    connector

    < 0.7 pF

    < 0.7 pF

    ConnectorProbingQuick connectionto many signalsin a smallfootprint,connector isdesigned intotarget

    Differential or single-endedclock, Single-ended data

    Differential or single-ended clock,

    Differential or single-ended data

    Single-ended clock, Single-ended data

    1.5 Gb/s

    600 Mb/s

    [1]

    250 mV p-p

    VmaxVmin200 mV

    300 mV p-p

    500 mV p-p

    500 mV p-p

    250 mV p-p

    500 mV p-p

    E5378A (100-pin Samtec)

    E5379A (100-pin Samtec)

    E5380A (38-pin Mictor)

    E5385A(100-pin Samtec)

    E5346A(38-pin Mictor)

    E5339A(38-pin Mictor)

    E5351A [2]

    (38-pin Mictor)

    34

    17

    34

    34

    34

    34

    34

    90-pin cableconnector

    40-pin cableconnector

    1.5 pF

    3 pF

    Flexibility and choice in creating qualityconnections to your target system

    Agilent Logic Analyzer Probing Solutions

    Easily connect with reliable,electrically and mechanicallyunobtrusive probing solutions

    Achieve low loading (< 0.7 pF), an easy connection and a smallfootprint with soft touchconnectorless probes

    Gain access to individual, widelydispersed signals with Agilent's

    new differential and single-ended general-purpose lead sets.

    Accurate measurements startwith reliable probing. AgilentTechnologies offers a widevariety of probing accessoriesthat support general-purposeand application-specificmeasurement needs.

    Figure 3. Agilents soft touch probescombine high-density, low loadingand differential capability into areliable, space-saving package.

    [1] Equivalent to the data rate of the logic analyzer the probe is attached to.[2] Requires isolation networks installed on the target.

    connect1

    General-Purpose Flying-Lead SetFlexibleconnection toindividual signals

    Differential or single-endedclock, Single-ended data

    Differential or single-endedclock, Differential data

    Single-ended clock,Single-ended data

    1.5 Gb/s

    [1]

    250 mV p-p

    VmaxVmin200 mV

    600 mV p-p

    E5382A

    E5381A

    E5383A

    17

    17

    17

    90-pin cableconnector

    40-pin cableconnector

    1.3 pF

    0.9 pF

    1.5 pF

    1.5 pF

    3.0 pF

  • 5

    Model No. 16760A[4] 16753A/54A/55A/56A[4] 16750B/51B/52B 16740A/41A/42A

    Channels/Module(Max. Channels onSingle Time Baseand Trigger)

    34(170)

    68(340)

    68(340)

    68(340)

    Supported SignalTypes

    Single-ended,Differential

    Single-ended,Differential

    Single-ended Single-ended

    Setup/HoldWindow(With Eye Finder),AdjustmentResolution

    500 ps,10 ps

    1 ns (600 ps typical),80 ps typical

    1.25 ns,100 ps

    1.25 ns,100 ps

    Eye Scan Yes Yes N/A N/A

    Max. TransitionalTiming Rate

    400 MHz 600 MHz 400 MHz 400 MHz

    Max. MemoryDepth (Half/FullChannels)[1]

    128M/64M[2] 16753A: 2M/1M16754A: 8M/4M

    16755A: 32M/16M16756A: 128M/64M

    16750B: 8M/4M16751B: 32M/16M16752B: 64M/32M

    16740A: 2M/1M16741A: 8M/4M

    16742A: 32M/16M

    High-SpeedTiming Zoom[3]

    N/A 4 GHz (250 ps) with64 K depth

    2 GHz (500 ps) with 16 K depth

    2 GHz (500 ps)with 16 K depth

    Max. TimingSampling Rate(Half/FullChannels)

    800 MHz (1.25 ns)

    1.2 GHz (833 ps) /600 MHz (1.67 ns)

    800 MHz (1.25 ns) /400 MHz (2.5 ns)

    800 MHz (1.25 ns) /400 MHz (2.5 ns)

    Max. State Clock 1.5 Gb/s 600 MHz 400 MHz 200 MHz

    Configure custom measurement solutionsfor demanding applications

    Measurement Modules

    A wide variety of timing andstate analysis modules providethe speed and memory depth toisolate and analyze your debugproblems. Create a customsolution or expand your existinganalysis system by selecting thetiming/state analyzer, patterngenerator, or oscilloscopemodules that meet your debugand validation needs.

    Choose from a wide variety ofmeasurement modules

    Acquire differential and single-ended signals with state analysisup to 1.5 Gb/s, 4-GHz timingzoom and memory depths up to 128 M samples

    Quickly validate signal integritywith hundreds of simultaneouseye diagrams

    Module Ordering Information for Agilent state and timing modules

    [1] Increased memory depth in half-channel timing mode only [2] 128 M in half-channel 1.25 Gb/s and .5 Gb/s modes only[3] All channels, all the time, simultaneous state and timing through same probe[4] Probes ordered separately

    NOTE: Probes are ordered separately. Please specify probes when ordering to ensure th