Agilent InfiniiVision 5000 Series Portable Oscilloscopes Data Sheet The Next Generation of Portable Oscilloscopes

Upload: others

Post on 07-Jun-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Agilent InfiniiVision 5000 Series Portable OscilloscopesData Sheet

The Next Generation of Portable Oscilloscopes

Page 2: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

2

• 100, 300, and 500 MHz bandwidths

• 2 or 4 channels

• MegaZoom III memory and display technology• 8Mptsacquisitionmemory• Upto100,000waveformsper

secondreal-timeupdaterate(page 5)

• High-definitionXGA(1024x768)displaywith256levelsofintensity grading

• Triggering and hardware accelerated decode for I2C, SPI, I2S, FlexRay,MIL-STD1553,CAN,LINandRS-232/UART(page6)

• Upto12bitsofverticalresolution,eveninsingle-shotacquisitions(page 7)

• Completeconnectivity–standard(page 6)• USB(2host,1device),LAN,

GPIB,XGAdisplayout• Fullremotecontrol,including

web browser • LXIclassCcompliant

• Manualsandin-scopehelpavailablein11languages

The new standard for everyday scopes

Traditional bench scopes are great for charac-terizing things that you know about. Agilent's MegaZoom III deep memory and fast update rates help you find the bugs you don’t know about.

Page 3: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

3

If you haven’t purchased an Agilent oscilloscope lately, why should you consider one now?

Leading-edge technology for all scope users

The InfiniiVision 5000 Series oscilloscopesleveragethesamethird‑generation MegaZoom III technologyblocksusedinourhigher performance bench and lab oscilloscopes–responsive deep memory, fast update rates with minimal “dead time,” analog-like display systems, and integrated serial analysis–anddeliverthemina compact package, at a price similar to oscilloscopes with older technology blocks.

Industry-leading customer support

Astheworld’sleadingtestandmeasurementvendor,Agilentmaintains the largest network of sales engineers, application engineers, supportengineersandtechnicians.From pre‑sales collaboration, to calibration,totrainingandconsulting,torepairandservicing,Agilentstandswithyouthroughoutthelifeofyourproduct.It’snoaccidentthatAgilenthassuchloyalcustomers.

Don’t take our word for it

Compare the InfiniiVision 5000 Series withyourcurrentbenchscope.Orcompareittooneofourcompetitors’newestscopes.You’llseewhyAgilenthasbeenthefastest-growing oscilloscope supplier since 1997 (CAGR,source:PrimeData2006TestInstrumentIndustryServiceMarketShareAnalysis).

Model BW (MHz) Channels Maximum sample rate Memory Update rate

DSO5012A 100 2 2GSa/s

DSO5014A 100 4 2GSa/s

DSO5032A 300 2 2GSa/s 8Mptsstd1 Upto100,000waveforms

DSO5034A 300 4 2GSa/s per second (page 5)

DSO5052A 500 2 4GSa/s1

DSO5054A 500 4 4GSa/s1

1 Maximumsamplerateandmemoryareachievedwhentwochannelsareinterleaved

Page 4: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

4

Why does deep memory matter?

See more time

Seeing more time is the most easily understooduseofdeepmemory.Themoresamplesyouacquire,themoretimeyoucanseeataparticularsamplerate.

Longcapturetimesgiveyoubettervisibilityintocause-effectrelationshipsinyourdesign,whichgreatlysimplifiesroot-causedebugging.Italsoallowsyoutocapturestart-upevents(likethestart-upsequenceinFigure1)inasingleacquisition.

Youdon’thavetostitchtogethermultipleacquisitionsorsetprecisetriggering conditions. Spend less timefindingevents,andmoretimeanalyzing them.

See more details

The relationship between memory depthandacquisitionrateisn’tasobvious.Allscopeshavea“banner”maximumsampleratespecification,butmanycanonlysustaintheseratesat a few timebase settings.

In the case of an oscilloscope with a 5GSa/sacquisitionrateand10-Kptsofmemory(Figure2),those10,000pointscan only fill 2 μs of time. Since scopes have10timedivisions,thesampleratedropsatanytime/divsettingbelow200ns/div.

Asaresult,ifyoulookat“slow/fast”eventslikeamodulatedsignal,youruntheriskofaliasingyoursignal.Oryoumaysimplymissoutonimportantsignaldetailswhenyouzoominonit.

Deepmemoryoscilloscopesletyousustainahighsamplerateoverlongerperiods of time.

Always fast, always on

MegaZoom III is the third generation of thefastanddeepmemoryarchitecturethatAgilentintroducedin1996.It’snotaspecialmode,unlikeotherdeep-memoryoscilloscopes.YouhaveaccesstoyourMegaZoommemoryatalltimes.Andthedisplaywillrespondinstantlytoyourcommandsasyouscalethe+/divsettingorpanandzoomintheDelayed(or“zoom”)window.

5 GSa/s, 10k memory 4 GSa/s, 1M memory

Inflection occurs at200 ns/div

Inflection occurs at10 µs/div (20 s with single-shot trigger)

Sam

ple

Rate

10 GSa/s

1 kSa/s

1 GSa/s

100 MSa/s

10 MSa/s

1 MSa/s

100 kSa/s

10 kSa/s

Time Base

1ns/div

10ns/div

100ns/div

1µs/div

10µs/div

100µs/div

1ms/div

10ms/div

100ms/div

1s/div

Figure 2.

Figure 1.

Page 5: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

5

Why does a fast update rate matter?

Ifthehumaneyehastroublediscerningabove30-50framespersecond, is there really a difference between 3,600 and 100,000 waveforms per second?Ifyouknowwhatyou’relookingfor,theanswerisprobably“no.”However,ifyouarehuntingforunknownsignalanomaliesor characterizing jitter, the answer is“yes.”

Acquisition time Dead time Dead timeAcquisition time

Figure 3. Reducing the dead time between acquisitions …

Figure 4. … improves your chances of finding random events like glitches

5000 Series TDS3000B WaveSurfer 400

Upda

te R

ate

(wav

efor

ms p

er se

cond

)

100,000

10,000

1,000

100

10

Time Base

1ns/div

10ns/div

100ns/div

1µs/div

10µs/div

100µs/div

Figure 5. Update rates of popular oscilloscopes using their default real-time acquisition mode

Catchproblemssoonerandcovermoreofyourdebugchecklist–our100,000waveformspersecondupdateratehelpsyoufindintermittentproblemsupto100xfasterthancompetitivescopes

Ifyouknowthatthereisaglitch in your system,it’seasytocaptureitusingapulse-widthtrigger.However,ifyouarejustbrowsingthroughyourdesign,yourchancesoffindingaglitchincreaseastheoscilloscope’supdaterateincreases.Ifaglitchoccursduringthe "dead time" between samples, youmissit(Figure3).WithMegaZoomIIItechnology,thedeadtimeismuchsmaller(Figure5).Ascopewithaslowerupdateratewillcapturetheglitcheventually(ifitrecurs),butmostengineersandtechniciansdon’thavethe time or patience to wait for their toolstocatchup.

Ifyouarecharacterizing signal jitter, afastupdaterategivesyouaccurateresultssooner.Andwhenthefastupdaterateiscombinedwiththe5000Series’XGAhigh-definitiondisplay(1024x768,256intensitylevels),subtledifferencesintheseacquisitionsbecomeobvious.

AndlikeallotheraspectsofMegaZoomIIItechnology,thisupdaterateisdeliveredasadefaultreal-timeacquisitionmode.It’s always fast, always on.

Page 6: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

6

Software options

Figure 7. Real-time totalize functions provide CAN bus efficiency and quality measurement statistics

CAN/LIN triggering and decode (N5424A or Option AMS on new scope purchases)Trigger on and decode serially transmitteddatabasedonCANandLIN protocols. This application not onlyprovidestriggeringoncomplexserialsignals,butalsoprovidesuniquehardware-accelerateddecodecapabilities. Hardware‑assisted triggeringanddecodeguarantees

youwillnevermissatriggereventoranomaly–unlikeotherscopesthathavetriggeringdeadtimebetweenacquisitions.

Thisapplicationrequiresa4-channelDSO.

Formoreinformation: www.agilent.com/find/CAN-LIN

Figure 6A. On-screen serial decode of an SPI packet

I2C/SPI serial trigger and decode (N5423A or Option LSS on new scope purchases)This application displays real‑time time‑aligned decode of I2C and SPI serialbuses.Hardware-assistedtriggeringanddecodeprovidetheindustriesfastestthroughputandupdaterate.Hardware-assistedtriggeringanddecodeguaranteesyouwillnevermissatriggereventoranomaly–unlikeotherscopesthat

havetriggeringdeadtimebetweenacquisitions.Listingwindowshowsatabularviewofallcapturespacketsthatmatchtheon-screenwaveformdata.

Thisapplicationrequiresa4-channelDSO.

Formoreinformation:www.agilent.com/find/I2C-SPI

Figure 6B. Mask testing uncovers infrequent signal anomalies

Mask testing (N5455A or Option LMT)Agilent'smasktestoption(OptionLMTorN5455A)forInfiniiVisionSeriesoscilloscopesprovidesafastandeasywaytotestyoursignalstospecifiedstandards,anduncoverunexpectedsignalanomalies,suchasglitches.Mask testing on other oscilloscopes isbasedonsoftware-intensivepro‑cessing technology, which tends to beslow.Agilent'sInfiniiVisionscopescanperformupto100,000real-timewaveformpass/failtestspersecond.

Thisprovidestestingthroughputsig‑nificantly faster than other mask test solutions,makingvalidpass/failsta‑tisticsavailablealmostinstantly.Formoreinformation:www.agilent.com/find/masktest

Figure 8. I2S Configuration PNG

I2S triggering and decode (N5468A or Option SND)Find and debugintermittenterrorsand signal integrity problems faster onI2Saudioprotocoldevices.Thisapplicationofferspowerfultriggeringandouruniquehardware-accelerateddecodeandlisterwindowsoyoucanmoreeasilyfinderrorsyoucouldmissusingotherserialbusdecodetools.

Thisapplicationrequiresa4-channelDSO. Formoreinformation: www.agilent.com/find/I2S

Page 7: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

7

RS-232/UART serial decode and trigger (N5457A or Option 232 on new scope purchases)TheapplicationletsyoueasilyviewtheinformationsentoveraRS-232orotherUARTserialbus.Displayreal-time time‑aligned decode of transmit andreceivelines.TheapplicationalsoenablestriggeringonRS-232/UARTconditions.

Figure 9. Trigger on and decode RS-232/UART transmission

Segmented memory (N5454A or Option SGM on new scope purchases)Segmented memory optimizes availablememoryfordatastreamsthathavelongdeadtimesbetweenactivity.Theapplicationismostusefulforanalyzingsignalactivityassociatedwithlaserpulses,serial

buses,andburstysignalssuchasradar.Viewanoverlayofallsignalsegments,includingserialdecode,whilehighlightingthecurrentsegment.Quicklymovebetweensegmentstoviewsignaldetailassociatedwithaspecific segment.

Formoreinformation:www.agilent.com/find/segmented

Thisapplicationrequiresa4-channelDSOandcanuseanycombinationofthescopeorlogicacquisitionchannels.

Formoreinformation: www.agilent.com/find/RS-232

Figure 10. Use segmented memory to optimize available memory

Software options (continued)

Figure 11. Time-correlated display of the FlexRay physical layer signal with protocol decoding.

FlexRay Measurements (N5432C or Option FLX on new scope purchases)Trigger on and time‑correlate FlexRay communicationwithphysicallayersignals.WithAgilent’suniquehard‑ware-accelerateddecoding,itprovidesthefastestdecodeupdateratesintheindustrywhilethescoperemainsresponsiveandfast.Alsoincludedwith this option is FlexRay eye‑diagram

mask testing and physical layer con‑formancetestsolution.Thisapplicationrequiresa4-channelDSO. For more information:

www.agilent/find/flexray

Figure 12. Time-correlated display of the MIL-STD 1553 physical layer signal with protocol decoding.

MIL-STD 1553 Serial Trigger and Decode (N5469A or Option 533 on new scope purchase)Thisapplicationprovidesintegrated MIL-STD1553serialbustrigger‑ing, hardware‑based decoding, and eye-diagrammasktestingtohelpyoudebugandcharacterizethe electrical/physical layer of MIL-STD1553serialbusesfaster

thanwithtraditional“bit-counting”methods.

This applicationrequiresa4-channelDSO.

For more information: www.agilent.com/find/1553

Page 8: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

8

Other nice features

High resolution mode Offersupto12bitsofverticalresolutioninreal-time,single-shotmode. This is accomplished by serially filteringsequentialdatapointsandmappingthefilteredresultstothedisplay when operating at base time settingsgreaterthan10µs/div.

Help is at your fingertipsAnembeddedhelpsystem–availablein11languages–givesyouquickanswersifyoudon’tunderstandafeature.Simplypressandholdthecorresponding front‑panel key, and a screenpopsuptoexplainitsfunction(Figure13).

Waveform math with FFTAnalysisfunctionsincludesubtract,multiply,integrate,anddifferentiate,aswellasFastFourierTransforms(FFT).

23 automatic measurements with statistics Getupto4simultaneous measurementswith5additionalstatisticsbeyondthecurrentvalue.Fastupdaterateprovidesstatisticaldataforenabledmeasurementssuchasmean,min,max,standarddeviationandcount.

Pressing [QuickMeas]bringsupthelastfourmeasurementsselected.Cursorsautomaticallytrackthemostrecentlyselectedmeasurement.

Figure 13. Press and hold a key for instant help

Figure 14. Measurement statistics allow you to have confidence in your measurements. Statistics can show that a measurement is not only correct at one moment, but that it has stabilized and has a low variance over time, giving it a higher statistical validity.

Page 9: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

9

Figure 15. View and analyze previously acquired scope data on a PC-based offline tool

Other nice features (continued)

Peak detect 250 ps peak detect on 500‑MHz models, 500 ps on 300‑MHz models and1nson100-MHzmodelshelpsyoufind narrow glitches.

AutoProbe interfaceAutomaticallysetsprobeattenuationfactorsandprovidespowerforselectedInfiniiumactiveprobes,includingtheaward-winning1130A1.5-GHzInfiniiMaxdifferentialactiveprobeand1156A1.5-GHzsingle-endedactiveprobesystems.

5-digit hardware counterMeasuresfrequencyuptothebandwidth of the scope.

Trig OutProvidesaneasywaytosynchronizeyourscopetootherinstruments.UsetheTrigOutporttoconnectyourscopetoafrequencycounterformoreaccuratefrequencymeasurementsortocrosstriggerotherinstruments.

Autoscale Displaysallactivesignals,andautomaticallysetsthevertical,horizontal and trigger controls.

HDTV triggerThe5000SeriessupportsanalogHDTV/EDTV triggering for standards like1080i,1080p,720pand480paswellasstandardvideotriggeringonany line within a field, all lines, all fields,andoddorevenfieldsforNTSC,SECAM,PALandPAL-Mvideosignals.

Serial Listing DisplayIn addition to seeing decoded packet dateonthebuswaveformitself,youcanviewallcapturepacketsinalistingviewwherethedecodematchestheon-screenwaveformdata.ThisfeatureisalsocompatiblewithAgilent’sSegmentedMemoryoption(SGM)

Oscilloscope toolsE2690BOscilloscopetoolspackage,licensedbyAgilentTechnologiesfromAmherstSystemsAssociates(ASA),makesiteasytoperformin-depthanalysisofcapturedsignals.MoreinformationcanbefoundintheOscilloscope Toolsdatasheet(Agilentpublicationnumber5989-3525EN).

Offline viewing and analysis (B4610A)SaveyourscopedatatoaUSBornetworkdriveandimportthedataintoaPC-basedofflineviewer.Panandzoom.Usesearchingandfiltering to gain insight on analog and digitalbuses.Emailthedatatoteammemberswhocanusethesametoolat their PCs. (www.agilent.com/find/InfiniiVisionOffline)

Figure 16. Serial listing display and decoded and all capture packets

Page 10: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Probing

Togetthemostoutofyourscope,youneed the right probes and accessories foryourapplication.That’swhyAgilentTechnologies offers a complete family ofinnovativepassiveandactiveprobesfor the 5000 Series scopes to help yougetyourjobdoneeasily.Formore

comprehensiveinformation,refertotheAgilent6000and5000SeriesOscilloscopeProbesandAccessoriesDataSheet(Agilentpublicationnumber5968-8153EN/ENUS)orvisitwww.agilent.com/find/scope_probes.

Selection guide

N2863A (shipped with 10073C 100 MHz and (shipped with 10076A N2771A 10070C 300 MHz models) 500 MHz models) high-voltage probe high-voltage probe

Probe bandwidth 20 MHz 300 MHz 500 MHz 250 MHz 50 MHz

Proberisetime(calculated) <17.5ns <1.16ns <700ps <1.4ns <7ns

Attenuationratio 1:1 10:1 10:1 100:1 1000:1

Inputresistance(when 1MΩ 10MΩ 2.2MΩ 66.7MΩ 100MΩ terminatedinto1MΩ)

Inputcapacitance Approx.70pF Approx.12pF Approx.12pF Approx.3pF Approx.1pF

Maximuminput 400VpkCATI 300Vrms 500VpkCATI 4000Vpk 15kVdc,10kVrms, (dc+peak ac) (mains isolated) (mains isolated) 30 kV dc + peak ac 400VpkCATII 400VpkCATII (post receptacle (post receptacle mains) mains)

Compensation range None 5‑30 pF 6‑15 pF 6‑20 pF 7‑25 pF

Probe sense No Yes Yes Yes No

U.S.price $175.00 $135.00 $311.00 $360.00 $1,203.00

10

Page 11: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Selection guide (continued)

Current probes Description

1147B 50-MHz115Acurrentprobe,AC/DC

1146A 100-kHzcurrentprobe,AC/DC

N2780A 2-MHz/500Acurrentprobe,AC/DC

N2781A 10-MHz/150Acurrentprobe,AC/DC

N2782A 50-MHz/30Acurrentprobe,AC/DC

N2783A 100-MHz/30Acurrentprobe,AC/DC

N2779A PowersupplyforN278xA

Active single-ended probes Description

1141A 200-MHzdifferentialprobe

1144A 800-MHzactiveprobe

1145A 2-channel750-MHzactiveprobe

1142A Powersupplyfor1144A/1145A

1156A 1.5-GHzactiveprobe

Active differential probes Description

N2790A 100MHz,1.4kVhigh-voltagedifferentialprobewithAutoProbeinterface

N2791A 25MHz,700Vhigh-voltagedifferentialprobe(batteryorUSBpowered)

N2792A 200MHz,+/-20Vdifferentialprobe(batteryorUSBpowered)

N2793A 800MHz,+/-15Vdifferentialprobe(batteryorUSBpowered)

1130A 1.5-GHzInfiniiMaxdifferentialprobeamplifier (OrderoneormoreInfiniiMaxprobeheadsorconnectivitykitsperamplifier.)

Probing (continued)

11

Page 12: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Connectivity

Ourcustomerstellusthatoscilloscopeconnectivityisanincreasinglyimportantfeatureoftheirtestinstruments.That’swhythe5000Series scopes come with the most comprehensivehardwareandsoftwareconnectivitytoolsintheirclass.

Hardware connectivity

Standardportsinclude:

• 2xUSBhostports(forexternalstorageandprintingdevices),oneon the front and one on the rear

• 1xUSBdeviceportforhigh-speedPCconnectivity

• 10/100MbitLANforInternet/intranetconnectivity

• GPIBtoalloweasymigrationintoexisting test systems

• XGAoutforexternalmonitorsandprojectors

LXI class C

LANeXtensionsforInstrumentation(LXI)isastandards-basedarchitecturefortestsystems.Byspecifyingtheinteraction of system components, LXIenablesfastandefficienttestsystemcreationandreconfiguration.The 5000 Series oscilloscopes follow specifiedLANprotocolsandadheretoLXIrequirementssuchasabuilt-inWebcontrolserver,IVI-COMdriver,andeasy-to-useSCPIcommands.ThestandardAgilentI/OLibrarySuitemakesiteasytoconfigureandintegrateinstrumentsinyoursystem.

IntuiLink toolbars

IntuiLinkgivesyouaquickwaytomovescreenshotsanddataintoMicrosoft®WordandExcel.Thesetoolbars can be installed from www.agilent.com/find/intuilink.

View Scope logic analyzer and oscilloscope correlation

View Scope enables simple time-correlatedmeasurementsbetween an InfiniiVision 5000 Series oscilloscopeandanAgilent1680/90or16800/900logicanalyzer.Scopeandlogicwaveformsareintegratedintoasinglelogicanalyzerwaveformdisplayforeasyanalysis–allwithasimplepoint-to-pointLANconnection.Youcanalsocross-triggertheinstruments,automaticallyde-skewthewaveforms,and maintain marker tracking between theinstruments.

Figure 17. Agilent Remote Front Panel running in a Web browser

Figure 18. The 5000 Series has just about any connection you might need – standard. Figure 19. Combine best-in-class instruments with a simple connection.

12

Page 13: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Performance characteristics

Acquisition

Samplerate DSO501xA/503xA:2GSa/aeachchannel DSO505xA:4GSa/shalfchannel1, 2 GSa/s each channel

Equivalent-timesamplerate 400GSa/s(whenreal-timemodeisturnedoff)

Memorydepth Standard8Mptshalfchannel1,4Mptseachchannel

Verticalresolution 8bits,upto12inhigh-resolutionoraveragingmodes

Peakdetection DSO501xA:1nspeakdetect DSO503xA:500pspeakdetect DSO505xA:250pspeakdetect

Averaging Selectablefrom2,4,8,16,32,64…to65536

Highresolutionmode Averagemodewith#avg=1 12bitsofresolutionwhen≥10µs/div,at4GSa/sor≥20µs/div,at2GSa/s

Filter Sinx/xinterpolation(singleshotBW=samplerate/4orbandwidthofoscilloscope,whicheverisless) withvectorsonandinreal-timemode

Vertical system

Scopechannels DSO50x2A:2Ch1and2simultaneousacquisition DSO50x4A:Ch1,2,3,and4simultaneousacquisition

Bandwidth(–3dB)2 DSO501xA:DCto100MHz DSO503xA:DCto300MHz DSO505xA:DCto500MHz

ACcoupled DSO501xA:3.5Hzto100MHz DSO503xA:3.5Hzto300MHz DSO505xA:3.5Hzto500MHz

Calculatedrisetime DSO501xA:3.5nsec (=0.35/bandwidth) DSO503xA:1.17nsec DSO505xA:700psec

Single-shotbandwidth DSO501xA:100MHz DSO503xA:300MHz DSO505xA:500MHz

1 Halfchanneliswhenonlyonechannelofchannelpair1-2isturnedon,oronechannelofchannelpair3-4isturnedon.2 Denoteswarrantedspecifications,allothersaretypical.Specificationsarevalidaftera30-minutewarm-upperiodand±10°Cfromfirmwarecalibrationtemperature.

13

Page 14: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Performance characteristics (continued)

Vertical system (continued)

Range1 2mV/divto5V/div(1MΩor50Ω)

Maximuminput Maximuminputvoltageforanaloginputs: CATI300Vrms,400Vpk;transientovervoltage1.6kVpk CATII100Vrms,400Vpk withN2863A10:1probe:CATI600V,CATII300V(DC+peakAC) with10073C10:1probe:CATI500Vpk,CATII400Vpk with50Ωinput:5Vrms,CATI

Offsetrange ±5Vonranges<10mV/div; ±20Vonranges10mV/divto200mV/div; ±75Vonranges>200mV/div

Dynamicrange ±8div

Inputimpedance 1MΩ±1%||12pFor50Ω±1.0%,selectable

Coupling AC,DC

BWlimit 25MHzselectable

Channel-to-channelisolation DCtomaxbandwidth>40dB

Standardprobes DSO501xA:10:1N2863Ashippedstandardforeachoscilloscopechannel DSO503xA:10:1N2863Ashippedstandardforeachoscilloscopechannel DSO505xA:10:110073Cshippedstandardforeachoscilloscopechannel

ProbeID AutoprobesenseandAutoProbeinterface Agilent-andTektronix-compatiblepassiveprobesense

ESDtolerance ±2kV

Noise,RMS,inputshorted DSO501xA:0.5%fullscaleor250µV,whicheverisgreater DSO503xA:0.5%fullscaleor300µV,whicheverisgreater DSO505xA:0.5%fullscaleor360µV,whicheverisgreater

DCverticalgainaccuracy2 ±2.0%fullscale

DCverticaloffsetaccuracy ≤200mV/div:±0.1div±2.0mV±0.5%offsetvalue; >200mV/div:±0.1div±2.0mV±1.5%offsetvalue

Singlecursoraccuracy1 ±DCverticalgainaccuracy+DCverticaloffsetaccuracy+0.2%fullscale(~1/2LSB) Example:for50mVsignal,oscilloscopesetto10mV/div(80mVfullscale),5mVoffset, accuracy=±2.0%(80mV)+0.1(10mV)+2.0mV+0.5%(5mV)+0.2%(80mV)=±4.785mV

Dualcursoraccuracy1 ±DCverticalgainaccuracy+0.4%fullscale(~1LSB) Example:for50mVsignal,oscilloscopesetto10mV/div(80mVfullscale),5mVoffset, accuracy=±2.0%(80mV)+0.4%(80mV)=±1.92mV

1 2mV/divisamagnificationof4mV/divsetting.Forverticalaccuracycalculations,usefullscaleof32mVfor2mV/divsensitivitysetting.2 Denoteswarrantedspecifications,allothersaretypical.Specificationsarevalidaftera30-minutewarm-upperiodand±10°Cfromfirmwarecalibrationtemperature.

14

Page 15: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Performance characteristics (continued)

Horizontal

Range DSO501xA:5nsec/divto50sec/div DSO503xA:2nsec/divto50sec/div DSO505xA:1nsec/divto50sec/div

Resolution 2.5psec

Timescaleaccuracy* Specification:25ppmfrom0°Cto40°C Characteristic:25ppm+1ppmper°Cfrom40°Cto55°C

Vernier 1-2-5incrementswhenoff,~25minorincrementsbetweenmajorsettingswhenon

Delayrange Pre-trigger(negativedelay):Greaterof1screenwidthor125µs Post-trigger(positivedelay):1sto500seconds

Channeldelta-taccuracy Samechannel:±0.0025%reading±0.1%screenwidth±20ps Channel-to-channel:±0.0025%reading±0.1%screenwidth±40ps Same channel example (DSO505xA):Forsignalwithpulsewidthof10µs,oscilloscopesetto5µs/div (50µsscreenwidth),delta-taccuracy=±0.0025%(10µs)+0.1%(50µs)+20ps=50.27ns

Modes Main,delayed,roll,XY

XY Bandwidth:Maxbandwidth Phaseerrorat1MHz:<0.5degrees ZBlanking:1.4Vblankstrace(useexternaltriggeronDSO50x2A,channel4onDSO50x4A)

Reference positions Left, center, right

Segmentedmemoryre-armtime8µs(minimumtimebetweentriggerevents)

Trigger system

Sources DSO50x2A:Ch1,2,line,ext DSO50x4A:Ch1,2,3,4,line,ext

Modes Auto,normal(triggered),single

Holdofftime ~60nsto10seconds

Trigger jitter 15 ps rms

*Denoteswarrantedspecification.Specificationsarevalidaftera30minutewarm-upperiodand±10°Cfromfirmwarecalibrationprocedure.

15

Page 16: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Performance characteristics (continued)

Trigger system (continued)

Selections Edge,pulsewidth,pattern,TV,duration Edge Triggeronarising,falling,oralternatingedgeofanysource Pulsewidth Triggerwhenapositive-ornegative-goingpulseislessthan,greaterthan,orwithinaspecifiedrange onanyofthesourcechannels. Minimumpulsewidthsetting: 5ns(DSO501xA) 2ns(DSO503xA,DSO505xA) Maximumpulsewidthsetting:10s Pattern Trigger at the beginning of a patternofhigh,low,anddon'tcarelevelsand/orarisingorfallingedge establishedacrossanyofthechannels,butonlyafterapatternhasbeenestablishedforaminimumof 2nsec.Thechannel’shighorlowlevelisdefinedbythatchannel’striggerlevel. Sequence ArmonEventA,triggeronEventB(edgeorpattern),withoptiontoresetonEventCortimedelay TV Triggerusinganyoscilloscopechannelonmostanalogprogressiveandinterlacedvideostandards includingHDTV/EDTV,NTSC,PAL,PAL-MorSECAMbroadcaststandards.Selecteitherpositiveor negativesyncpulsepolarity.ModessupportedincludeField1,Field2,allfields,alllines,oranyline withinafield.TVtriggersensitivity:0.5divisionofsyncsignal.Triggerholdofftimecanbeadjustedin half field increments. Duration Triggeronamulti-channelpatternwhosetimedurationislessthanavalue,greaterthanavalue, greaterthanatimevaluewithatimeout,orinsideoroutsideofasetoftimevalues. Minimumdurationsetting:2ns Maximumdurationsetting:10s CAN TriggeronCAN(ControllerAreaNetwork)version2.0Aand2.0Bsignals.Triggeronthestartofframe (SOF)bit(standard).N5424AoptionsupportstriggeringonremoteframeID(RTR),dataframeID (~RTR),remoteordataframeID,dataframeIDanddata,errorframe,allerrors,acknowledgeerrorand overloadframe. FlexRay Trigger on FlexRayFrames,errors,eventsandcycle-multiplexedtriggering.N5432Coroption FLXsupportsalsotriggeringonparticularframetypessymbolically,suchasStartupframes,Nullframe, Syncframe,etc.,aswellasBooleanNOTframetypes.

LIN Trigger on LIN (Local Interconnect Network) sync break at beginning of message frame (standard). N5424AoptionsupportstriggeringonframeID. I2C Trigger on I2C (Inter-ICbus)serialprotocolatastart/stopconditionoruserdefinedframewithaddress and/ordatavalues.Alsotriggeronmissingacknowledge,addresswithnoacq,restart,EEPROMread, and 10‑bit write.

SPI Trigger on SPI (SerialProtocolInterface)datapatternduringaspecificframingperiod.Supportspositive andnegativeChipSelectframingaswellasclockIdleframinganduser-specifiednumberofbitsper frame. RS-232/UART View the informationsentoveraRS-232serialbus.Displayreal-timetime-aligneddecodeoftransmit andreceivelines.TheapplicationalsoenablestriggeringonRS-232/UARTconditions. MIL‑STD 1553 Trigger on specific Command/StatusWords,DataWords,anderrorconditions.

AutoScale Findsanddisplaysallactivechannels,setsedgetriggermodeonhighest-numberedchannel,sets verticalsensitivityonchannels,timebasetodisplay~1.8periods.Requiresminimumvoltage> 10mVpp,0.5%dutycycleandminimumfrequency>50Hz.

16

Page 17: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Performance characteristics (continued)

Channel triggering

Range(internal) ±6divfromcenterscreen

Sensitivity1 <10mV/div:greaterof1divor5mV;≥10mV/div:0.6div

Coupling AC(~10Hz),DC,noisereject,HFrejectandLFreject(~50kHz)

1 Denoteswarrantedspecifications,allothersaretypical.Specificationsarevalidaftera30-minutewarm-upperiodand±10°Cfromfirmwarecalibrationtemperature.

External (EXT) triggering DSO50x2A DSO50x4A

Inputimpedance 1MΩ±3%||12pFor50Ω±1% 1.015kΩ±5%

Maximuminput CATI300Vrms,400Vpk;transientovervoltage1.6kVpk ±15V CATII100Vrms,400Vpk withN2863A10:1probe:CATI600V,CATII300V(DC+peakAC) with10073C10:1probe:CATI500Vpk,CATII400Vpk 5Vrmswith50-Ωinput,CATI

Range DCcoupling:triggerlevel±1Vand±8V ±5V

Sensitivity For±1Vrangesetting: DCto100MHz,500mV DCto100MHz,100mV,>100MHztobandwidthof the oscilloscope, 200 mV For±8Vrangesetting: DCto100MHz,250mV;>100MHztobandwidthof the oscilloscope, 500 mV

Coupling AC(~10Hz),DC,noisereject,HFrejectandLFreject(~50kHz)

ProbeID AutoprobesenseandAutoProbeinterface Agilent-andTektronix-compatiblepassiveprobesense

Display system

Display 6.3‑inch (161 mm) diagonal color TFT LCD

Displayupdaterate Upto100,000waveforms/secinreal-timemode

Resolution XGA: 768verticalby1024horizontalpoints(screenarea); 640verticalby1000horizontalpoints(waveformarea) 256levelsofintensityscale

Controls Waveformintensityonfrontpanel.Vectorson/off;infinitepersistenceon/off, 8x10gridwithintensitycontrol

Built-inhelpsystem Key-specifichelpdisplayedbypressingandholdingkeyorsoftkeyofinterest

Real-timeclock Timeanddate(useradjustable)

17

Page 18: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Performance characteristics (continued)

Measurement features

Automaticmeasurements Measurementsarecontinuouslyupdated.Cursorstracklastselectedmeasurement.

Voltage Peak-to-peak,maximum,minimum,average,amplitude,top,base,overshoot,preshoot,RMS, standarddeviation,Ratio(dB)

Time Frequency,period,+width,–widthanddutycycleonanychannel.Risetime,falltime,XatmaxY (timeatmaxvolts),XatminY(timeatminvolts),delay,andphaseonoscilloscopechannelsonly.

Counter Built-in5-digitfrequencycounteronanychannel.Countsuptotheoscilloscope’sbandwidth.

Thresholddefinition Variablebypercentandabsolutevalue;10%,50%,90%defaultfortimemeasurements

Cursors Manuallyorautomaticallyplacedreadoutofhorizontal(X,ΔX,1/ΔX)andvertical(Y,ΔY).Tracking Cursorsprovidesanadditionalmodeforcursorpositioningbeyondthecurrentmanualmethod.When cursortrackingisenabled,changingacursor'sx-axispositionresultsinthey-axiscursortrackingthe correspondingy-axis(voltage,current,etc.)value.Additionallylogicorscopechannels canbedisplayedasbinaryorhexvalues.

Waveformmath f(g(t)) g(t):1,2,3,4,1-2,1+2,1x2,3-4,3+4,3x4 f(t):1-2,1+2,1x2,3-4,3+4,3x4,FFT(g(t)),differentiated/dtg(t),integrate∫g(t)dt,square root√g(t)Where1,2,3,4representanaloginputchannels1,2,3,and4 Note:Channels3and4onlyavailableonDSO5xx4Amodels

MeasurementStatistics Statisticaldataforenabledmeasurementssuchasmean,min,max,standarddeviationandcount

FFT

Points Upto10kptsinprecisionmode

SourceofFFT 1,2,1+2,1-2,1x2,DSO5xx4A:3,4,3+4,3-4,3x4; where1,2,3,4representtheanalogchannelinputs1,2,3,and4

Window Rectangular,flattop,hanning,BlackmanHerris

Noisefloor –50to–90dBdependingonaveraging

Amplitude DisplayindBV,dBmat50Ω

Frequencyresolution 0.05/timeperdiv

Maximumfrequency 50/timeperdiv

Storage

Save/recall 10setupsandtracescanbesavedandrecalledusinginternalnon-volatilememory. Optionalsecureenvironmentmodeensuressetupsandtracesarestoredtointernalvolatilememoryso dataiserasedwhenpowerisremoved.ComplianttoNISPOMChapter8requirements.

Storagetypeandformat USB1.1hostportsonfrontandrearpanels Imageformats:BMP(8-bit),BMP(24-bit),PNG(24-bit) Dataformats:XandY(time/voltage)valuesinCSVformat,ASCIIXYformat,BINformat Trace/setupformats:Recalled

I/O

Standardports USB2.0highspeeddevice,twoUSB1.1hostports,10/100-BaseTLAN,IEEE488.2GPIB, XGAvideooutput

Maxtransferrate IEEE488.2GPIB:500kbytes/sec USB(USBTMC-USB488):3.5Mbytes/sec 100MbpsLAN(TCP/IP):1Mbytes/sec

Printercompatibility Currentprintersupportcanbefoundathttp://agilent.com/find/InfiniiVision-printers

18

Page 19: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Performance characteristics (continued)

General characteristics

Physicalsize 35.4cmwidex18.8cmhighx17.4cmdeep(withouthandle) 38.5cmwidex18.8cmhighx17.4cmdeep(withhandle)

Weight Net:4.1kg(9lbs) Shipping:approximately9kgs(20lbs)

Probecompoutputfrequency~ 1.2kHz,amplitude~2.5V

Triggerout 0to5Vintoopencircuit(~23nsdelay) 0to2.5Vinto50Ω

Kensingtonlock Connectiononrearpanelforsecurity

Power requirements

Linevoltagerange 100-120V,50/60/400Hz;100-240V,50/60Hzautoranging

Linefrequency 50/60Hz,100-240VAC;440Hz,100-132VAC

Powerusage 120Wmax

Environmental characteristics

Ambienttemperature Operating-10°Cto+55°C;non-operating–40°Cto+70°C

Humidityoperating 95%RHat40°Cfor24hour;non-operating90%RHat65°Cfor24hour

Altitude Operatingto4,570m(15,000ft);non-operatingto15,244m(50,000ft)

Vibration AgilentclassGPandMIL-PRF-28800F;Class3random

Shock AgilentclassGPandMIL-PRF-28800F(operating30g,1/2sine,11-msduration,3shocks/axisalong majoraxis.Totalof18shocks)

Pollutiondegree Normallyonlydrynon-conductivepollutionoccurs.Occasionallyatemporaryconductivitycausedby condensationmustbeexpected.

Indooruse Ratedforindooruseonly

Other

Measurementcategories CATI

Regulatoryinformation SafetyIEC61010-1:2001/EN61010-1:2001 Canada:CSAC22.2No.61010-1:2004 USA:UL61010-1:2004

Supplementaryinformation TheproductherewithcomplieswiththerequirementsoftheLowVoltageDirective73/23/EECandthe EMCDirective89/336/EEC,andcarriestheCE-markingaccordingly. TheproductwastestedinatypicalconfigurationwithHP/Agilenttestsystems. Productspecifications,characteristics,anddescriptionsinthisdocumentaresubjecttochange withoutnotice.

19

Page 20: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Ordering information

Available models

Product number Description

DSO5012A 100MHz,2-channelportableoscilloscope

DSO5014A 100MHz,4-channelportableoscilloscope

DSO5032A 300MHz,2-channelportableoscilloscope

DSO5034A 300MHz,4-channelportableoscilloscope

DSO5052A 500MHz,2-channelportableoscilloscope

DSO5054A 500MHz,4-channelportableoscilloscope

Standard features

Product number Description

Warranty 3-yearreturn-to-Agilentwarranty

Hardcopyuser’sguide ABA Printeduser'sguideinEnglish ABD Printeduser'sguideinGerman ABF Printeduser'sguideinFrench ABZ Printeduser'sguideinItalian ABJ Printeduser'sguideinJapanese AC6 Printeduser'sguideinKorean AB9 Printeduser'sguideinPortuguese AKT Printeduser'sguideinRussian AB2 Printeduser'sguideinsimplifiedChinese ABE Printeduser'sguideinSpanish AB0 Printeduser'sguideintraditionalChinese Power cord 900 UnitedKingdom 901 Australia/NewZealand 902 ContinentalEurope 903 UnitedStates/Canada 906 Switzerland 912 Denmark 917 SouthAfrica/India 918 Japan 919 Israel 920 Argentina 921 Chile 922 China 927 Brazil/Thailand

Probes One probe per channel DSO501x,DSO503x:N2863A DSO505x:10073C

Software AgilentIOLibraries

Interfacelanguagesupport GUImenus:English,simplifiedChinese,traditionalChinese,Korean,Japanese

Otherdocumentation Serviceguide(CD-ROM,English),CertificateofCalibration,DeclarationofConformance

Miscellaneous Protectivefrontcover

20

Page 21: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

Options

Product number Description

SEC Secureenvironmentmode–ProvidescompliancewithNationalIndustrialSecurity ProgramOperatingManual(NISPOM)Chapter8requirements

A6J ANSIZ540-compliantcalibration

080 8Mptsmemoryupgrade(frombase1Mpts)

Serial data analysis applicationsOption number – Option number – user installed factory installed Description

N5424A AMS CAN/LINautomotivetriggeringanddecode(4-channelmodelsonly)

N5423A LSS I2C/SPI serial decode option (for 4‑channel models only)

N5457A 232 RS-232/UARTtriggeringanddecode(4channelmodelsonly)

N5468A SND I2SAudioTriggeringanddecode(4channelmodelsonly)

N5454A SGM Segmentedmemory

N5455A LMT Masklimittesting

Available softwareProduct number Description

Oscilloscope Tools E2690B OscilloscopeToolssoftware(U.S.andCanada)

N5385B OscilloscopeToolssoftware(International)

E2693B 1yearupdatesubscriptionforoscilloscopetools(U.S.andCanada)

N5388B 1yearupdatesubscriptionforoscilloscopetools(International)

(YouwillorderOption005–ScopeGuide.High-bandwidthAgilentoscilloscopessupport morecomprehensiveversionsofOscilloscopeTools.PleaserefertoAgilentPublication 5989-3525EN:E2690B Oscilloscope Tools for more details.)

N5427A Secureenvironmentmode-providescompliancewithNationalIndustrialSecurity ProgramOperatingManual(NISPOM)Chapter8requirements(afterpurchaseoption)

N2762A 8Mptsacquisitionmemoryupgrade

Accessories Product number Description

N2916B Rackmountkitfor6000and5000Seriesoscilloscopes

N2917B Transitcasefor6000and5000Seriesoscilloscopes

N2760A Softcarryingcasefor5000Seriesoscilloscopes

N2790A 100MHz,1.4kVhigh-voltagedifferentialprobewithAutoProbeinterface

N2791A 25MHz,700Vhigh-voltagedifferentialprobe(batteryorUSBpowered)

N2792A 200MHz,+/-20Vdifferentialprobe(batteryorUSBpowered)

N2793A 800MHz,+/-15Vdifferentialprobe(batteryorUSBpowered)

CableProduct number Description

10833A GPIBcable,1mlong

Ordering information (continued)

21

Page 22: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

22

Agilent Technologies OscilloscopesMultiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications

Page 23: Agilent InfiniiVision 5000 Series Portable Oscilloscopes

MicrosoftisaU.S.registeredtrademarkofMicrosoft Corporation.

www.lxistandard.orgLANeXtensionsforInstrumentsputsthepowerofEthernetandtheWebinsideyourtestsystems.Agilent isafoundingmemberoftheLXIconsortium.

Agilent Channel Partners

www.agilent.com/find/channelpartnersGetthebestofbothworlds:Agilent’smeasurementexpertiseandproductbreadth, combined with channel partnerconvenience.

FormoreinformationonAgilent Technologies’products,applicationsor services,pleasecontactyourlocalAgilentoffice.Thecompletelistisavailableat:www.agilent.com/find/contactus

AmericasCanada (877)8944414Brazil (11)41973600Mexico 018005064800 UnitedStates (800)8294444

Asia PacificAustralia 1800629485China 8008100189HongKong 800938693India 1800112929Japan 0120(421)345Korea 0807690800Malaysia 1800888848Singapore 18003758100Taiwan 0800047866OtherAPCountries (65)3758100

Europe & Middle EastBelgium 32(0)24049340Denmark 4545801215Finland 358(0)108552100France 0825010700* *0.125€/minuteGermany 49(0)70314646333 Ireland 1890924204Israel 972-3-9288-504/544Italy 390292608484Netherlands 31 (0) 20 547 2111Spain 34(91)6313300Sweden 0200-882255UnitedKingdom 44(0)1189276201For other unlisted countries: www.agilent.com/find/contactusRevised:October11,2012

Productspecificationsanddescriptionsinthisdocumentsubjecttochangewithoutnotice.

©AgilentTechnologies,Inc.2010,2012PrintedinUSA,December3,20125989-6110EN

www.agilent.comwww.agilent.com/find/5000a

AgilentAdvantageServicesiscommittedtoyoursuccessthroughoutyourequip‑ment’slifetime.Tokeepyoucompetitive,wecontinuallyinvestintoolsandprocessesthatspeedupcalibrationandrepairandreduceyourcostofownership.YoucanalsouseInfolineWebServicestomanageequipmentandservicesmoreeffectively.Bysharingourmeasurementandserviceexpertise,wehelpyoucreatetheproductsthatchangeourworld.

www.agilent.com/quality

www.agilent.com/find/advantageservices

Quality Management SystemQuality Management SysISO 9001:2008Agilent Electronic Measurement Group

DEKRA Certified