Compact Substation > Comply with Zone2 Hazardous Area Classification for Oil & Gas Distribution > Applicable for harsh environmental conditions > Related Standard IEC 62271-202,1

Upload: others

Post on 09-Aug-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AET-SCK-1307-L.Eng SCK2 Compact Substation · 2021. 2. 8. · IEC 62271-200 : MV Switchgears IEC 60529 : IP Protection Classification IEC 60721-1 : Environmental Classification. Base

Compact Substation

> Comply with Zone2 Hazardous Area Classification for Oil & Gas Distribution > Applicable for harsh environmental conditions> Related Standard IEC 62271-202,1

Page 2: AET-SCK-1307-L.Eng SCK2 Compact Substation · 2021. 2. 8. · IEC 62271-200 : MV Switchgears IEC 60529 : IP Protection Classification IEC 60721-1 : Environmental Classification. Base

Opera�ng Condi�onsAl�tude : 1000 mAmbient Temperature : -25 ... +50 0 CSeismic Resistance : Horizontal 0,5 G / Ver�cal 0,4 GIP Protec�on Class : Up to IP 54Rated Voltage : Up to 40,5 kVRated Current : Depends on opera�ng voltageShort Circuit Current : Depends on short circuit currentFrequency : 50/60 HzApplica�ons : Oil&Gas Sector Hazardous Area Classifica�on : Zone2

In 2012, Ak�f Elektroteknik who has a professional experience about Power Sector since 1981, started to manufacture SCK 2 type Compact Substa�on for Oil & Gas Sector in complience with Zone2 Hazardous Area Classifica�on. SCK 2 Type Compact Substa�on is produced in complience with IEC 62271-202 and equipped with special opera�ng and safety systems.

OverviewSCK 2 Type Compact Substa�ons includes MV Switchgear Room, LV Switchgear Room, MV/LV Distrubiton Transformer Room, Ba�ery Room and Emergency Supply Panel.

In addi�on to switching system, it is equipped with HVAC system, Fire and Smoke detec�on system, Fire Ex�nguisher system, Modbus communica�on system, Internal and External Lightening, Sockets, Earthing and Floor insulator system.

SCK 2SCK 2Compact Substa�on

Related StandardsIEC 62271-202 : Prefabricated Substa�onsIEC 60076 : Distribu�on TransformersIEC 62271-200 : MV SwitchgearsIEC 60529 : IP Protec�on Classifica�onIEC 60721-1 : Environmental Classifica�on

Page 3: AET-SCK-1307-L.Eng SCK2 Compact Substation · 2021. 2. 8. · IEC 62271-200 : MV Switchgears IEC 60529 : IP Protection Classification IEC 60721-1 : Environmental Classification. Base

BaseCompact Substa�ons are assembled on a base. Base are made of NPU or NPI shapes according to load on the floor and NPU and NPI shapes are covered hot dip galvanized.

FrameFrame of Compact Substa�on is made of 5mm2 St-37 and covered with hot dip galvanized for long term using.

Compact Substation Base

DoorsDoors are made of Sandwich Panels. Doors can be opened to 120 0 outside and designed against to 20 J mechanical shock.

Compact Substation Door

Design And Structural Features DesignCompact Substa�ons can be designed in accordance with requirement of project. Equipment in Compact Substa�ons can be provided as ex-proof.

DimensionDimensions of Compact Substa�on can be designed in accordance with requirement of project and are specified in view of the fact that rooms, dimensions of switching equipment, opera�ng condi�ons and opera�ng area.

Wall Insulated factory production panels

Wall and RoofSandwich panels are used on walls and roof. Internal wall and external wall of sandwich panel are covered with 100-275 gr/m2 zinc sheet against to corrosion. Insula�ng is provided with polyurethane. Non-flammability Class of panels is Euro Class B.

Compact Substation Roof

Page 4: AET-SCK-1307-L.Eng SCK2 Compact Substation · 2021. 2. 8. · IEC 62271-200 : MV Switchgears IEC 60529 : IP Protection Classification IEC 60721-1 : Environmental Classification. Base

LV Switchgear RoomIn Low Voltage (LV) Room, withdrawable MCC distribu-�on panel, UPS, LV Distrubu�on Panel, HVAC Panel and Modbus Panel can be installed. Dimensions of LV Room are specified in accordance with equipment dimensions in the room.

Transformer RoomIn Transformer room, Dry type transformer and oil type transformer can be used. Dimensions of transformer room are specified in accordance with power of trans-former. MV switchgear and transformer are connected with XLPE Cables and Transformer and LV Switchgear are connected with cable or busbar in accordance with requirement of project.

Ba�ery RoomThere are Ni-Cd ba�eries and DC brekaers in ba�ery room. If it is required, Zone2 Hazardous Area Claasifi-ca�on can be provided in ba�ery room.

Electrical Features And RoomsMV Switchgear RoomIn MV Switchgear Room, Metal Enclosed, Metal Clad and RMU can be used. Dimensions of MV Room are specified in accord-ance with equipment dimensions in the room.

Page 5: AET-SCK-1307-L.Eng SCK2 Compact Substation · 2021. 2. 8. · IEC 62271-200 : MV Switchgears IEC 60529 : IP Protection Classification IEC 60721-1 : Environmental Classification. Base

Interior Ligh�ng, External Light-ing, Cau�on Lamps, Sockets and EarthingAll rooms in Compact Substa�on are equipped Lightening System in compliece with standarts. Internal ligh�ng include emergency ligh�ng unit. In case of power interrup�on, emergency ligh�ng unit provides ligh�ng in substa�on. External ligh�ng equipment and sockets are selected in complience with Atex cer�ficated for Zone2 Hazardous Area.

Emergency Exit Armatures are installed on the way of the doors. Emergency Exit Armatures include emergency ligh�ng unit. At the moment of energy interrup�on, emergency ligh�ng unit con�nues ligh�ng.

There are two type of earthing in compact substa�ons. Electrical devices are connected to an isolated earthing busbar. Separate earthing system is used for doors, base, walls and roof to avoid electrical shock in case of touching.

Safety EquipmentFloorFloor covering is made of non-flammable rubber. It has A1 Classifica�on and 50kV insula�on level.

Fire Detec�on and Fire Ex�nguisher System : All rooms are equipped with fire and smoke detectors. Addi�onally, CO2 tubes and control panel provides gas emmisions to all rooms on the moment of danger. In case of emer-gency in dangerous situa�ons HVAC system is disabled and warning lights and alarm become ac�ve.

Air Condi�oning System In Compact Substa�on, HVAC is used to keep stable internal temperature and humidity. Stabiliza�on in all rooms is provided by air ducts. Gas in HVAC is cooled via an external unit.

Page 6: AET-SCK-1307-L.Eng SCK2 Compact Substation · 2021. 2. 8. · IEC 62271-200 : MV Switchgears IEC 60529 : IP Protection Classification IEC 60721-1 : Environmental Classification. Base

MerkezBayraktar Blv. Şehit sk. No: 5 Ak�f Plaza 34775 Ümraniye Istanbul - TürkiyeTe l : +90 216 314 93 20Fax : +90 216 314 93 60

FabrikaAkşemset�n mah. Çatalca sk. No:113 06930 Sincan Ankara - TürkiyeTe l : +90 312 269 46 02 Fax : +90 312 269 45 01

Orta Gerilim Hücreler

Anahtarlama Ürünleri

Köşk Tipi Trafo Merkezleri

Mobil Trafo Merkezleri

Dağı�m Trafoları

Dirençler

Enerji Kalitesi Çözümleri

Tıbbi Güç Dağı�m Sistemleri

Kondasatör ve Reaktörler

Sayaç Otomasyonu ve Faturalama

Ölçme ve Yöne�m Sistemleri

Sekonder Koruma Röleleri

Kaçak Akım Röleler

Yüksek Güç Dönüştürücüleri ve Redresörler

Güneş Enerjisi Çözümleri

Cer Gücü Dağı�m Merkezi

Depo Alanı Çözümleri

Araçüstü Ekipmanlar

Eubiq Esnek Fiş - Priz Sistemleri

Doc.

Nr.

AET-

SCK-

1307

/L.E

ng O

win

g to

per

iodi

cal i

mpr

ovem

ents

of o

ur p

rodu

cts t

he su

pplie

d pr

oduc

ts m

ay d

iffer

in so

me

deta

ils fr

om th

e da

ta st

ated

in th

e pr

ospe

ctus

mat

eria

l. Pu

blish

ed b

y Ak

�f E

lekt

rote

knik

A.S

. Dat

a su

bjec

t to

alte

ra�o

n w

ithou

t no�

ce.

Desig

n &

Cre

a�on

: Ak�

f Gro

up /

Phot

os: A

k�f G

roup

- St

ock.

xchn

g &

Shu

�ers

tock