ael product catalog - 3rd edition
TRANSCRIPT
Product GuideProduct GuideEdition ThreeEdition Three
Roadway
Decorative
Security
Area
Flood
Controls
Poles
The AEL AdvantageFor more than 50 years, American Electric Lighting (an Acuity Brands Company) has produced the highestquality outdoor, utility, and infrastructure lighting products. Continuing in our tradition of excellence, EditionThree of the AEL Product Guide offers a complete package of products for these applications, includingRoadway, Decorative, Area, Security, and Floodlighting luminaires, as well as Poles and Photocontrols.However the real AEL Advantage extends beyond our product breadth…it’s the quality and innovation inour products…it’s our knowledgeable sales, service and support teams …and it’s the reliability of ourdelivery and product performance. Read on for more about the AEL Advantage.
Nighttime FriendlyTM
In response to the increased demand for products that reduce light pollution, Acuity Brands Lightingestablished the “Nighttime Friendly” designation to recognize products across our brands thatminimize light pollution. Nighttime Friendly products provide superior optical control consistent withthe goals of USGBC LEED® and Green Globes™ product criteria for light pollution reduction. Productsmarked as Nighttime Friendly must meet stringent photometric requirements–at a minimum, these products are fullcutoff and emit no more than 10% of their total lumens above 80 degrees from nadir. Look for the Nighttime Friendlylogo throughout this edition of the AEL catalog.
Preferred Selection Catalog NumbersNot sure what to order? These numbers (visible throughout the catalog) represent our most popular productconfigurations–many are available for immediate shipment. Look to these numbers for a quick-reference ordering guide.
Utility-Friendly FeaturesAEL products are designed with several utility-friendly features in mind, such as tool-less entry, tool-less adjustablephotocontrol receptacles, terminal blocks, “breathing seal” gaskets, interchangeable optics, and wildlife shields.Check individual product pages for more details, or visit us at www.americanelectriclighting.com to view ourSpecification Sheets.
Dark-to-Light (DTL) PhotocontrolsThe AEL product offering includes Dark-to-Light Photocontrols, the leader in electronicphotocontrol technology. DTL controls are available in combination with AEL products (wherenoted) or in stand-alone configurations.
Dedicated Sales and ServiceOur products are marketed through a combination of sales agents and a dedicated factory sales force that targetsutilities, municipalities and specifiers. Each of our sales representatives (many of whom are Lighting Certified) hasintimate knowledge of their particular market, as well as our products. Our outstanding Customer Service and TechSupport teams are equally knowledgeable and friendly, and more importantly, never outsourced.
Industry-Leading WarrantyAEL was the first to offer a 6-year warranty on luminaire electrical components* across our entire product line andremains the industry leader on product warranties. How are we able to offer longer coverage than the competition?Put simply, we build products that perform reliably, and we stand behind the products we build.
* See Terms & Conditions for full warranty information.
We are pleased to present the third edition of the American Electric Lighting (AEL) and Dark to Light (DTL) product guide. AEL is acompany on the move in the public infrastructure and utility lighting market, with products that have been successful for over 55years in roadway, security, area, flood and decorative outdoor lighting. DTL has been a large part of that success by offering top-of-the-line photocontrols. Our goal is to continue to provide the superior design, quality and reliability that our customers demand.
On each product page, AEL has identified a selection of products designated as “Preferred Selection”. Products shown as“Preferred Selection” catalog numbers are frequently ordered, standard products that will be quickly shipped to satisfy yourapplication requirements. Included in each section are ballast and optical matrices for each product. Use them to helpdetermine the best ballast and optical configurations for your needs. Also, a selection guide has been added to the DTL pages tohelp you choose the best photocontrols for your application.
For the most up-to-date product information, photometric files, specification sheets and other technical data that AEL and DTLhave to offer, visit our website, www.americanelectriclighting.com.
We at American Electric Lighting are confident this catalog will be a useful tool for you. We look forward to working with you tosatisfy your lighting requirements. Thank you for your continued support.
Sincerely,
The AEL Team
AmericanElectricLighting
Product GuideEdition Three
For more information, contactCustomer Service at:
1-800-754-0463
1
AEL “Preferred Selection” ProgramAEL products are offered with an extensive list of source, ballast,
optical and option choices for customers with specificapplication requirements. For most applications a listingof “Preferred Selection” catalog numbers is provided for
each product. These products are frequentlyordered and can be shipped in as little as 1week in many cases. Consult with your AEL
sales representative for actual lead time.Preferred Selection Program
T A B L E O F C O N T E N T S
Product Guide
American Electric Lighting®
Roadway Lighting
2
Roadway Cobrahead Series 125Product Overview ...............................26Ordering Information ..........................27
Roadway Cutoff Cobrahead Series 125Product Overview ...............................28Ordering Information ..........................29
Roadway Cobrahead Series 325Product Overview ...............................30Ordering Information ..........................31
Roadway Cutoff Cobrahead Series 325Product Overview ...............................32Ordering Information ..........................33
Roadway Cobrahead Series 327Product Overview ...............................34Ordering Information ..........................35
Multi-Mount™ Series 285Product Overview ...............................36Ordering Information ..........................37
InterState™ II Luminaire Series 775Product Overview ...............................38Ordering Information ..........................39
LPS Roadway/Area Luminaire Series SRXProduct Overview ...............................40Ordering Information ..........................41
ROADWAY LIGHTING
CVMProduct Overview ...............................10Ordering Information ..........................11
CVLProduct Overview ...............................12Ordering Information ..........................13
DuraStar® Roadway Lighting System Series 20Product Overview ...............................14Ordering Information ..........................15
DuraStar® Roadway Lighting System Series 30Product Overview ...............................16Ordering Information ..........................17
Roadway Cobrahead Series 115Product Overview ...............................18Ordering Information ..........................19
Roadway Cutoff Cobrahead Series 115Product Overview ...............................20Ordering Information ..........................21
Roadway Cobrahead Series 315Product Overview ...............................22Ordering Information ..........................23
Roadway Cutoff Cobrahead Series 315Product Overview ...............................24Ordering Information ..........................25
3Product Guide
T A B L E O F C O N T E N T S
American Electric Lighting®
Roadway Lighting, Decorative Post Top Lighting
LPS Roadway/Area Luminaire Series SP2Product Overview ...............................42Ordering Information ..........................43
Underpass Series 581/681Product Overview ...............................44Ordering Information ..........................45
Wallpack Series 882Product Overview ...............................46Ordering Information ..........................47
SignLite Series 875Product Overview ...............................48Ordering Information ..........................49
Accessories..........................................................................50
Ballast Matrices ..................................................................52
DECORATIVE AND POST-TOP LIGHTING
Valiant®
Product Overview ...............................60Ordering Information ..........................61
American Revolution Deluxe SeriesProduct Overview ...............................62Ordering Information ..........................63
American Revolution Series 247Product Overview................................64Ordering Information ..........................65
Georgian SeriesProduct Overview................................66Ordering Information ..........................67
Bainbridge SeriesProduct Overview................................68Ordering Information ..........................69
Marietta SeriesProduct Overview................................70Ordering Information ..........................71
Sumter SeriesProduct Overview................................72Ordering Information ..........................73
Cresthill ClassicProduct Overview................................74Ordering Information ..........................75
Cresthill SphereProduct Overview................................76Ordering Information ..........................77
Cresthill CentennialProduct Overview................................78Ordering Information ..........................79
Cresthill GlassProduct Overview................................80Ordering Information ..........................81
T A B L E O F C O N T E N T S
Product Guide
American Electric Lighting®
Decorative Post Top Lighting, Security Lighting, Area Lighting
4
LexingtonProduct Overview................................82Ordering Information ..........................83
Branson Product Overview................................84Ordering Information ..........................85
Contemporary Series 245Product Overview................................86Ordering Information ..........................87
TwistPack Series TWTProduct Overview................................88Ordering Information ..........................89
Decorative PolesChadsworth Series
Product Overview................................90Ordering Information ..........................91
New Albany Series Product Overview................................92Ordering Information ..........................93
Statesboro Series Product Overview................................94Ordering Information ..........................95
Waycross Series Product Overview................................96Ordering Information ..........................97
Weatherproof Receptacles .............................................98
Ballast Matrices ..............................................................100
SECURITY LIGHTINGNEMA Head Series 11
Product Overview..........................108Ordering Information.....................109
NEMA Head Package Series 11 PKG Product Overview..........................110Ordering Information.....................111
Series 11 “L” Package Product Overview..........................112Ordering Information.....................113
Dusk to Dawn Series DTDProduct Overview..............................114Ordering Information ........................115
Series 165Product Overview..............................116Ordering Information ........................117
Accessories .......................................................................118
Ballast Matrices ................................................................119
AREA LIGHTINGASA
Product Overview..............................122Ordering Information ........................123
PESProduct Overview..............................124Ordering Information ........................125
5Product Guide
T A B L E O F C O N T E N T S
American Electric Lighting®
Area Lighting, Floodlighting
LuxMaster® Classic Series LMProduct Overview..............................142Ordering Information ........................143
Accessories.......................................................................144
Ballast Matrices ...............................................................148
FLOODLIGHTINGACP Series
Product Overview..............................154Ordering Information ........................155
UltraFloodTM Series 75Product Overview..............................156Ordering Information ........................157
UltraFloodTM Series 77Product Overview..............................158Ordering Information ........................159
Energy Saver Series CESProduct Overview..............................160Ordering Information ........................161
Quartz Flood Series 570Product Overview..............................162Ordering Information ........................162
Quartz Flood Series 474Product Overview..............................163Ordering Information ........................163
PEMProduct Overview..............................126Ordering Information ........................127
VMRProduct Overview..............................128Ordering Information ........................129
VLRProduct Overview..............................130Ordering Information ........................131
AVL-BIAProduct Overview..............................132Ordering Information ........................133
AVLProduct Overview..............................134Ordering Information ........................135
LuxMaster® Luminaire 53Product Overview..............................136Ordering Information ........................137
LuxMaster® Luminaire 153 Product Overview..............................138Ordering Information ........................139
LuxMaster® Classic Series LSProduct Overview..............................140Ordering Information ........................141
D7790 SeriesProduct Overview .............................181Ordering Information ........................181
DD Series DiagnosticProduct Overview .............................182Ordering Information ........................182
DPN Series Part NightProduct Overview .............................183Ordering Information ........................183
DBE Series ButtonProduct Overview .............................184Ordering Information ........................184
Shorting and Open CapsProduct Overview .............................185Ordering Information ........................185
Accessories ........................................................................186
Recommendation Chart ......................................................186
ANSI Color Chart..................................................................186
Product Guide6
T A B L E O F C O N T E N T S
American Electric Lighting®
Floodlighting, Photocontrols
AmeriSport Series ASPProduct Overview .............................164Ordering Information ........................165
Sportslighting Series SPFProduct Overview .............................166Ordering Information ........................167
Accessories.......................................................................168
Ballast Matrices ...............................................................173
ELECTRONIC PHOTOCONTROLSDP Series Silicon
Product Overview .............................176Ordering Information ........................176
DE Series Filtered SiliconProduct Overview .............................177Ordering Information ........................177
DP 1704 Utility PremiumProduct Overview .............................178Ordering Information ........................178
DX Series BasicProduct Overview .............................179Ordering Information ........................179
DUX Series BasicProduct Overview .............................180Ordering Information ........................180
7Product Guide
T A B L E O F C O N T E N T S
American Electric Lighting®
Poles, Options & Accessories
TECHNICAL DATAHPS Replacement Starters............................................232
Lamp Selection ................................................................233
Fuse Ratings.....................................................................234
Luminaire Classification Systems. ...............................240
Floodlighting Applications. ............................................241
Floodlight Calculations...................................................242
Roadway Lighting Application Design.........................243
Terms & Conditions.........................................................244
Index..................................................................................246
POLESIllustrated Samples .........................................................188
Wind Map.........................................................................189
Florida Wind Rating ........................................................190
General Information........................................................191
RSA ...................................................................................192
RTA ...................................................................................193
RSAH .................................................................................194
SSA ...................................................................................195
SSAH .................................................................................196
RSS ...................................................................................197
RTS ...................................................................................198
SSS ...................................................................................199
STS ...................................................................................200
STSH..................................................................................201
Pole Options .....................................................................202
Aluminum Mounting Brackets ......................................203
Steel Mounting Brackets ...............................................204
RTF ...................................................................................205
RTFDB ...............................................................................206
SSF ...................................................................................207
STC ...................................................................................208
SPRTC ...............................................................................209
SPRTS ...............................................................................213
RTAU..................................................................................216
RTSU..................................................................................220
AMAW / SMAW...............................................................222
AMAC / SMAC .................................................................224
SMAWL.............................................................................226
Traditional Wood Pole Arms..........................................228
Traditional Concrete Pole Arms....................................229
Product Guide8
NOTES
ROADWAY LIGHTING
Corvus™ CVM Series ..............................................10
Corvus™ CVL Series ................................................12
DuraStar® Series 20 ................................................14
DuraStar® Series 30 ................................................16
Roadway 115 ............................................................18
Roadway 115 Cutoff .................................................20
Roadway 315 ............................................................22
Roadway 315 Cutoff .................................................24
Roadway 125 ............................................................26
Roadway 125 Cutoff .................................................28
Roadway 325 ............................................................30
Roadway 325 Cutoff .................................................32
Roadway 327 .............................................................34
Multi-Mount™ 285.....................................................36
InterState™ II 775 ....................................................38
LPS Roadway - SRX .................................................40
LPS Roadway - SP2..................................................42
Underpass 581/681 ...................................................44
Heavy-Duty Wallpack 882.......................................46
SignLite 875 ...............................................................48
Accessories ..............................................................50
Ballast Matrices .......................................................52
American Electric Lighting®
9
P R O D U C T O V E R V I E W
10 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Corvus™ Series CVMRoadway Lighting70-250W HPS, 70-250W MH
Features:The contemporary style of the CorvusTM CVM combines superior mechanicalconstruction, a choice of light distributions, lamp types, and mounting optionsto make it a truly flexible luminaire for a variety of applications
Die-cast aluminum body has direct access to the lamp and electricalcomponents from the top
Universal mounting system can be secured on a 2-3/8" to 3" O.D. vertical tenon,or on a 1-7/8” to 2-3/8” O.D. horizontal arm
Using a single door entry and a standard hood support brace; full access tofixture interior including electrical gear and the optical chamber isstraighforward, reducing maintenance time
Tool-less lamp access and a removable power pad with quick disconnectsallow for ease of gear and lamp replacement
Hydroformed anodized aluminum reflector is enclosed by tempered shockresistant curved glass. The luminaire is sealed with a silicone gasket.
Photocontrol receptacle is adjustable without tools reducing installation time
Ambient rated 40°C outdoor
Optical chamber is IP66 rated standard, gear compartment is IP44 rated
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Applications:City streetscapesResidential streetsCity streetsParking lotsCampuses
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Corvus Medium is .74 sq. ft.Approx. Wt. = 34 lbs.
PREFERRED SELECTION CATALOG NUMBERS
CVM 10S RN 120 R2CVM 10S CA MT1 R2CVM 17M SC MT1 R2CVM 25M SC MT1 R3
N E W
11Product Guide
Example: C V M 1 0 S C A M T 1 R 2
O R D E R I N G I N F O R M A T I O N
Corvus™ Series CVMRoadway Lighting
70-250W HPS, 70-250W MH
CVM Corvus MediumArchitecturalCobrahead
R2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWAMR Mag Reg (3 Coil)1
120 120V208 208V240 240V277 277V347 347V480 480VMT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V
07 70W10 100W13 100/150W
Wired 100W14 100W
Wired 150W15 150W17 175W20 200W25 250W
S HPSM MH
Paint(blank) Gray (standard)
BK BlackBZ Bronze
WH White
Terminal Block2
(blank) Terminal Block (standard)T2 Wired to L1 to L2 PositionT3 3 Wire Operation
(L1, N, L2 Position)
Fusing3
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 230, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard) NR No Photocontrol Receptacle4
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Misc.BL Bubble LevelPC Photocontrol Included per
Voltage Specified4
SS Stainless Steel FastenersLA Lightning Arrestor5H 50 Hertz Ballast Cycle5
NN No NEMA Label on HousingSH Shorting Cap4
SC2 Cutoff optics for R2 Distribution Only
Notes:1 150W maximum2 T3 option only available with 240, 480, DT2, DT4, MT23 Not available in MT, TT, DT voltages4 PC and SH not available with NR5 Limited availability, consult factory
DistributionBallast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 52 for compatibility.
Optic DistributionR2 R3 R2 SC2
07S � � �
10S � � �
10M � � �
15S � � �
17M � � �
25S � � �
25M � � �
P R O D U C T O V E R V I E W
12 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Corvus™ Series CVLRoadway Lighting100-400W HPS, 100-400W MH
Features:The contemporary style of the CorvusTM CVL combines superior mechanicalconstruction, a choice of light distributions, lamp types, and mounting optionsto make it a truly flexible luminaire for a variety of applications
Die-cast aluminum body with access to the lamp from the bottom, and a gearaccess canopy made of precision die-cast aluminum on the top
The tool-less top-entry captive hood allows for full access to the removableelectrical power pad, with quick disconnects for user-friendly gearreplacement
Separate tool-less optical chamber access reduces time spent during lampexchange
Universal mounting system can be secured on a 2-3/8" vertical tenon, or on a1-5/8” to 2-3/8” O.D. horizontal arm
Hydroformed anodized aluminum reflector is enclosed by tempered shockresistant curved glass. The luminaire is sealed with a silicone gasket.
Photocontrol receptacle is adjustable without tools reducing installation time
Optical chamber is IP66 rated standard, gear compartment is IP44 rated
Ambient rated 40°C outdoor, except for Mag Reg.
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Applications:RoadwaysResidential streetsCity streetsParking lotsCampuses
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Corvus Large is 1.03 sq. ft.Approx. Wt. = 43 lbs.
PREFERRED SELECTION CATALOG NUMBERS
CVL 25M SC MT1 R3CVL 40M SC MT1 R3CVL 25S CA MT1 R3CVL 40S CA MT1 R3
N E W
13Product Guide
O R D E R I N G I N F O R M A T I O N
Corvus™ Series CVLRoadway Lighting
100-400W HPS, 100-400W MH
Example: C V L 4 0 S C A M T 1 R 3
CVL Corvus LargeArchitecturalCobrahead
R2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWAMR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480VMT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V
10 100W13 100/150W
Wired 100W14 100W
Wired 150W15 150W17 175W20 200W25 250W23 250/400W
Wired 250W24 250/400W
Wired 400W31 310W40 400W
S HPSM MH
Mounting(blank) Mast Arm (standard)
TT Tenon Top
Paint(blank) Gray (standard)
BK BlackBZ Bronze
WH White
Terminal Block1
(blank) Terminal Block (standard)T2 Wired to L1 to L2 PositionT3 3 Wire Operation
(L1, N, L2 Position)Listing
UL UL ListedCS CSA Certified
MX NOM Listed
Fusing2
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 230, 240, 480V)
Options
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard) NR No Photocontrol Receptacle4
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Misc.5H 50 Hertz Ballast Cycle3
BL Bubble LevelPC Photocontrol Included per
Voltage Specified4
SS Stainless Steel FastenersLA Lightning Arrestor
NN No NEMA Label on HousingSH Shorting Cap4
Notes:1 T3 option only available with 240, 480, DT2, DT4, MT22 Not available in MT, TT, DT voltages3 Limited availability - consult factory4 PC and SH not available with NR
DistributionBallast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 52 for compatibility.
Optic DistributionR1 R2 R3
17M � � -25S - � �
25M � � -31S - � �
40S - � -40M � � �
PREFERRED SELECTION CATALOG NUMBERS
P R O D U C T O V E R V I E W
14 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Revolutionary DuraLock™ docking system provides modular installation andinterchangeability for easy maintenance. Rugged die-cast, powder-coateddocking station mounts securely to mast-arm to ensure secure wiring andlong-lasting stability. Durable lightweight lighting fixture positively docks byplugging in with a 20° locking twist
High-efficiency optical system maximizes light output while minimizing glare
Starter component is externally accessible for easy maintenance and is fullyencapsulated for long life
Wildlife shield is cast into the docking station (not a separate piece) and iseasily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms
Cam-latch doorframe allows easy re-lamping without tools
Large surface area "breathing seal" gasket, seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture
Photocontrol receptacle is adjustable without tools
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul base socket standard
Suitable for -30°C MH / -40°C HPS
Optical chamber is IP64 rated standard
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Applications:RoadwaysResidential areasCoastal areas — salt/corrosive environmentsParking lotsStorage areas
DuraStar™ Series 20Roadway Lighting50-150W HPS, 175W MH
DIMENSIONS
Effective Projected Area (EPA)The EPA for the DuraStar™ is .56 sq. ft.The EPA for the DuraStar™ sag lens, is .70 sq. ft.Approx. Wt. = 14 lbs.
Vertical Tenon Mount
Horizontal Arm Mount
20 10S RN 120 R2 FG20 10S RN 120 R3 FG20 15S RN 120 R2 FG
15Product Guide
O R D E R I N G I N F O R M A T I O N
DuraStar™ Series 20Roadway Lighting
50-150W HPS, 175W MH
Example: 2 0 1 0 S R N 1 2 0 R 3 F G L C P C
20 DuraStarCobrahead
SA Sag Acrylic LensSP Sag Polycarbonate LensFG Flat Glass Clear Tempered4
R2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWI
120 120V208 208V240 240V277 277V347 347V480 480VMT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240V
05 50W07 70W10 100W15 150W17 175W
S HPSM MH3
Mounting(blank) Duralock Docking Station Set
for 1-1/4” Mast ArmM2 2-bolt Internal 2” Setting, for
Duralock Docking Stationfor 2” Mast Arm
ML Less Duralock Docking StationVT Vertical Tenon Docking Station
Paint(blank) Gray (standard)
ListingUL UL ListedCS CSA Certified
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
NR No Photocontrol Receptacle1
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Options
Misc.PC Photocontrol Included per
Voltage Specified1
PK Package (includes lamp,photocontrol, 5’ supply-wire,mast arm, hardware)
SS Stainless Steel Fasteners(external)
PL Distribution PatternIndicator Label
5H 50 Hertz Ballast Cycle2
SH Shorting Cap1
LCU Low Copper Alloy ContentDocking Station (less than 1%)
Notes:1 PC, SH not available with NR option2 Limited availability, please contact your local
American Electric Lighting representative3 175W MH available standard, other wattages please
contact your local American Electric Lightingrepresentative
4 Nighttime FriendlyTM optic
Optics
DistributionBallast VoltageWattage / SourceSeries
Optic Distribution
Refer to the ballast matrix onpage 52 for compatibility.
R2SA R3SA R2SP R3SP R2FG R3FG05S � � � � � �
07S � � � � � �
10S � � � � � �
15S � � � � � �
17M - - � � - -
P R O D U C T O V E R V I E W
16 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Revolutionary DuraLock™ docking system provides modular installation andinterchangeability for easy maintenance. Rugged die-cast, powder-coateddocking station mounts securely to mast-arm to ensure secure wiring andlong-lasting stability. Durable lightweight lighting fixture positively docks byplugging in with a 20° locking twist
High-efficiency optical system maximizes light output while minimizingobjectionable glare
Starter component is externally accessible for easy maintenance and is fullyencapsulated for long life
Wildlife shield is cast into the docking station (not a separate piece) and iseasily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms
Die-cast trigger latch on door frame enables easy and secure one-handopening for re-lamping and maintenance
Large surface area "breathing seal" gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture
Photocontrol receptacle is adjustable without tools
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul base socket standard
Suitable for -30°C MH / -40°C HPS
Optical chamber is IP64 rated standard
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
DuraStar™ Series 30Roadway Lighting200-400W HPS, 175-400W MH
Effective Projected Area (EPA)The EPA for the DuraStar™ Series 30 is 1.24 sq. ft. flat glassThe EPA for the DuraStar™ Series 30 is 1.43 sq. ft. sag glassApprox. Wt. = 30 lbs.
DIMENSIONS
Vertical Tenon Mount
PREFERRED SELECTION CATALOG NUMBERS
30 25S CA MT1 R2 FG30 40S CA MT1 R3 FG
Horizontal Arm Mount
17Product Guide
Example: 3 0 2 5 S C A M T 1 R 3 F G L C P C
O R D E R I N G I N F O R M A T I O N
DuraStar™ Series 30 Roadway Lighting
200-400W HPS, 175-400W MH
30 DuraStarCobrahead
SG Sag Glass Clear TemperedFG Flat Glass Clear Tempered6
R2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWAMR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480VMT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap wired 480V2
17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 250W1
24 250/400WWired 400W1
S HPSM MH
Mounting(blank) Duralock Docking Station Set
for 1-1/4” Mast ArmM2 2-bolt Internal 2” Setting, for
Duralock Docking StationML Less Duralock Docking StationVT Vertical Tenon Docking Station
Color(blank) Gray (standard)
ListingUL UL ListedCS CSA Certified
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
NR No Photocontrol Receptacle3
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Options
Starter4
(blank) Externally Mounted Encapsulated Plug-In
OB Open Board Internal
Misc.PC Photocontrol Included per
Voltage Specified3
SS Stainless Steel Fasteners(external)
PK Includes Lamp, LC, PC, ArmPL Distribution Pattern
Indicator Label5H 50 Hertz Ballast Cycle5
SH Shorting Cap3
LCU Low Copper Alloy Content Docking station (less than 1%)
Notes:1 Not available in 5-tap2 250W and 400W only3 PC, SH not available with NR option4 Available in HPS only5 Limited availability, please contact your local
American Electric Lighting representative6 Nighttime FriendlyTM optic
Optics
DistributionBallast VoltageWattage / SourceSeries
R2SG R3SG R2FG R3FG20S � � � �
25S � � � �
31S � � � �
40S � � � �
17M � � � �
25M � � � �
40M � � � �
Optic Distribution
Refer to the ballast matrix onpage 53 for compatibility.
P R O D U C T O V E R V I E W
18 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Two-bolt mast arm mount provides easy, secure installation and adjustabilityfor arms from 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) diameter. Optional four-boltmounting provides extra security in high-vibration applications
Die-cast trigger latch on doorframe enables easy and secure one-handopening for re-lamping and maintenance
Large surface area "breathing seal" gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) on the two-boltunit and is easily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution withborosilicate glass, acrylic, or polycarbonate refractor
NEMA wattage label, terminal block, and NEMA photocontrol receptacle arestandard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul base socket standard
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 115Roadway Lighting35-400W HPS, 175-250W MH
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 115 is 0.9 sq. ft.Approx. Wt. = 19 lbs.
DIMENSIONS
27"(686)
13"(330)
10.1"(257)
10.1"(257)
PREFERRED SELECTION CATALOG NUMBERS
115 10S RN 120 R2 DA115 15S CA MT1 R2 DA EC115 15S RH 120 R2 DA115 25S CA MT1 R3 DG EC
19Product Guide
Example: 1 1 5 1 5 S R N 1 2 0 R 2 D G L C P C
O R D E R I N G I N F O R M A T I O N
Roadway Series 115Roadway Lighting
35-400W HPS, 175-250W MH
115 Single DoorCobrahead
DA Drop AcrylicPrismatic Refractor
DP Drop PolycarbonatePrismatic Refractor
DG Drop GlassPrismatic Refractor
R2 Roadway Type IIR3 Roadway Type IIIRX Roadway Type II
4-way3
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWAMR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480VMT1 Multi-tap Wired 120VMT8 Multi-tap Wired 208VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V
03 35W05 50W07 70W10 100W13 100/150W
Wired 100W14 100/150W
Wired 150W15 150W17 175W20 200W25 250W40 400W1
S HPSM MH
Mounting(blank) 2-bolt Internal
EF External Fitter (2-bolt only)4B 4-bolt InternalM2 2-bolt Internal 2” SettingE2 External Fitter 2” Mast Arm
(2-bolt only)
Paint4
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 to L2 PositionT3 3 Wire Operation
(L1, N, L2 Position)5
ListingUL UL ListedCS CSA Certified
Fusing6
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle7
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter1
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified7
BL Bubble LevelSS Stainless Steel Fasteners
(external)CF Charcoal FilterPL Distribution Pattern
Indicator LabelLA Lightning Arrestor
(Void UL/CSA Certified Options)5H 50 Hertz Ballast Cycle2
SH Shorting Cap7
HK Hinge KeeperBF 3G Vibration8
RG Rubber Silicone Optical Gasket
Notes:1 For HPS products only2 Limited availability, please contact your local
American Electric Lighting representative3 DG option only4 Other colors available, please contact your local
American Electric Lighting representative5 T3 option only available with 240, 480, DT2, DT4, MT26 Not available in MT, TT, DT voltages7 SH, and PC not available with NR option8 Tested to withstand 3G vibration, 4B option required
Optics
DistributionBallast VoltageWattage / SourceSeries
R2DA R3DA R2DP R3DP R2DG R3DG RXDG03S � � � � � � �
05S � � � � � � �
07S � � � � � � �
10S � � � � � � �
15S � � � � � � �
20S - - � � � � �
25S - - � � � � �
40S - - - - � � �
17M � � � � � � �
25M - - � � � � �
Optic Distribution
Refer to the ballast matrix onpage 53 for compatibility.
P R O D U C T O V E R V I E W
Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 115Roadway Lighting — Cutoff Style35-250W HPS, 175-250W MH
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 115 with cutoff is .74 sq. ft.Approx. Wt. = 19 lbs.
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 115 with sag glass is .82 sq. ft.
DIMENSIONS
27"(686)
13"(330)
6-1/2"(165)
6-1/2"(165)
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Two-bolt mast arm mount provides easy, secure installation and adjustabilityfor arms from 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) diameter. Optional four-boltmounting provides extra security in high-vibration applications
Die-cast trigger latch on doorframe enables easy and secure one-handopening for re-lamping and maintenance
Large surface area "breathing seal" gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) on the two-boltunit and is easily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms.
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution with eitherflat or sag clear tempered glass
NEMA wattage label, terminal block, and NEMA photocontrol receptacle arestandard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul base socket standard
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31
20
PREFERRED SELECTION CATALOG NUMBERS
115 10S CA MT1 R2 FG EC
21Product Guide
Example: 1 1 5 1 5 S C A M T 1 R 3 F G L C P C H P
O R D E R I N G I N F O R M A T I O N
Roadway Series 115Roadway Lighting — Cutoff Style
35-250W HPS, 175-250W MH
115 Single DoorCobrahead
FG Flat Glass Clear Tempered9
SG Sag Glass Clear Tempered
R2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWIMR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480VMT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V
03 35W05 50W07 70W10 100W13 100/150W
Wired 100W14 100/150W
Wired 150W15 150W17 175W20 200W25 250W
S HPSM MH
Mounting(blank) 2-bolt Internal
EF External Fitter (2-bolt only)4B 4-bolt Internal
M2 2-bolt Internal 2” SettingE2 External Fitter 2” Mast Arm
(2-bolt only)
Paint2
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation
(L1, N, L2 Position)3
ListingUL UL ListedCS CSA Certified
Fusing4
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle5
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter6
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified5
BL Bubble LevelSS Stainless Steel Fasteners (external)CF Charcoal FilterPL Distribution Pattern
Indicator LabelLA Lightning Arrestor
(Void UL/CSA Certified Options)5H 50 Hertz Ballast Cycle1
SH Shorting Cap5
HK Hinge KeeperHP High Performance7
BF 3G Vibration8
RG Rubber Silicone Optical Gasket
Notes:1 Limited availability, please contact your local
American Electric Lighting representative2 Other colors available, please contact your local
American Electric Lighting representative3 T3 option only available with 240, 480, DT2, DT4, MT24 Not available in MT, TT, DT voltages5 PC and SH not available with NR option6 For HPS products only7 FG optics only8 Tested to withstand 3G vibration, 4B option required
Refer to accessory section for shield options9 Nighttime FriendlyTM optic
Optics
DistributionBallast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 53 for compatibility.
Optic DistributionR2 SG R3 SG R2 FG R3 FG R2 FG HPR3 FG HP
03S � � � � � �
05S � � � � � �
07S � � � � � �
10S � � � � � �
15S � � � � � �
20S � - � - - -25S � - � - - -17M � � �1 �1 - -25M � � �1 �1 - -Notes:1 Use deluxe/coated lamp LD option
P R O D U C T O V E R V I E W
22 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Die-cast secondary Power Pad door places all electrical components on oneeasily interchangeable module with quick disconnects to main fixture housing
Two-bolt mast arm mount provides easy, secure installation and adjustabilityfor arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Optional four-boltmounting provides extra security in high-vibration applications
Die-cast trigger latch on lens frame enables easy and secure one-handopening for re-lamping
Large surface area "breathing seal" gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) on the two-boltunit and is easily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution withborosilicate glass, acrylic or polycarbonate refractor
NEMA wattage label, terminal bl ock, and NEMA photocontrol receptacle arestandard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul base socket standard
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 315Roadway Lighting — with Power Door35-400W HPS, 175-250W MH
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 315 is 0.9 sq. ft.Approx. Wt. = 19 lbs.
PREFERRED SELECTION CATALOG NUMBERS
315 10S CA MT1 R2 DA EC315 10S RN 120 R2 DA EC315 15S RN 120 R2 DA EC
23Product Guide
Example: 3 1 5 1 0 S M R D T 2 R 3 D G N R B L
O R D E R I N G I N F O R M A T I O N
Roadway Series 315Roadway Lighting — with Power Door
35-400W HPS, 175-250W MH
315 Power DoorCobrahead
DA Drop AcrylicPrismatic Refractor
DP Drop PolycarbonatePrismatic Refractor
DG Drop GlassPrismatic Refractor
R2 Roadway Type IIR3 Roadway Type IIIRX Roadway Type II
4-way2
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWA
MR Mag Reg (3 Coil)
120 120V208 208V220 220V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V
03 35W05 50W07 70W10 100W13 100/150W
Wired 100W14 100/150W
Wired 150W15 150W17 175W20 200W25 250W40 400W
S HPSM MH
Mounting(blank) 2-bolt Internal
EF External Fitter (2-bolt only)4B 4-bolt Internal
M2 2-bolt Internal 2” settingE2 External Fitter 2” Mast Arm
(2-bolt only)
Paint3
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation
(L1, N, L2 Position)4
ListingUL UL ListedCS CSA Certified
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Options
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle6
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter7
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified6
BL Bubble LevelSS Stainless Steel Fasteners (external)CF Charcoal FilterPL Distribution Pattern
Indicator LabelLA Lightning Arrestor
(Void UL/CSA Certified Options)5H 50 Hertz Ballast Cycle1
NN No NEMA Label on HousingSH Shorting Cap6
HK Hinge KeeperBF 3G Vibration8
RG Rubber Silicone Optical Gasket
Notes:1 Limited availability, please contact your local
American Electric Lighting representative2 DG option only3 Other colors available, please contact your local
American Electric Lighting representative4 T3 option only available with 240, 480, DT2, DT4, MT25 Not available in MT, TT, DT voltages6 SH, PC not available with with NR option7 Available in HPS only8 Tested to withstand 3G vibration, 4B option required
Optics
DistributionBallast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 54 for compatibility.
R2DA R3DA R2DP R3DP R2DG R3DG RXDG03S � � � � � � �
05S � � � � � � �
07S � � � � � � �
10S � � � � � � �
15S � � � � � � �
20S - - � � � � �
25S - - � � � � �
31S - - - - � � �
40S - - - - � � �
17M � � � � � � �
25M - - � � � � �
Optic Distribution
P R O D U C T O V E R V I E W
24 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance. Die-cast secondary Power Pad door places all electricalcomponents on one easily interchangeable module with quick disconnects tomain fixture housing
Two-bolt mast arm mount provides easy, secure installation and adjustabilityfor arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Optional four-boltmounting provides extra security in high-vibration applications
Die-cast trigger latch on lens frame enables easy and secure one-handopening for re-lamping
Large surface area “breathing seal” gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) on the two-boltunit and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution with eitherflat or sag clear tempered glass
NEMA wattage label, terminal block, and NEMA photocontrol receptacle arestandard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul socket standard
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 315Roadway Lighting — Cutoff Style with Power Door35-400W HPS, 175-250W MH
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 315with Cutoff is 0.98 sq. ft.Approx. Wt. = 19 lbs.
27"(686)
13"(330)
6-1/2"(165)
6-1/2"(165)
Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315with sag glass is 1.06 sq. ft.
PREFERRED SELECTION CATALOG NUMBERS
315 10S CA MT1 R2 FG EC315 25S CA MT1 R2 FG EC315 15S CA MT1 R2 FG EC
25Product Guide
Example: 3 1 5 1 0 S C A D T 2 R 3 F G N R H P
O R D E R I N G I N F O R M A T I O N
Roadway Series 315Roadway Lighting — Cutoff Style with Power Door
35-400W HPS, 175-250W MH
315 Power DoorCobrahead
FG Flat Glass Clear Tempered9
SG Sag Glass Clear Tempered
R2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWA
MR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT7 Tri-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V
03 35W05 50W07 70W10 100W13 100/150W
Wired 100W14 100/150W
Wired 150W15 150W17 175W20 200W25 250W40 400W
S HPSM MH
Mounting(blank) 2-bolt Internal 1-1/4” Setting
(standard)EF External Fitter (2-bolt only)4B 4-bolt Internal
M2 2-bolt Internal 2” SettingE2 External Fitter 2” Mast Arm
(2-bolt only)
Paint2
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation
(L1, N, L2 Position)3
ListingUL UL ListedCS CSA Certified
Fusing4
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle5
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter6
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified5
BL Bubble LevelSS Stainless Steel Fasteners (external)CF Charcoal FilterPL Distribution Pattern
Indicator LabelLA Lightning Arrestor
(Void UL/CSA Certified Options)5H 50 Hertz Ballast Cycle1
NN No NEMA Label on HousingSH Shorting Cap5
HK Hinge KeeperHP High Performance7
BF RG Vibration8
RG Rubber Silicone Optical Gasket
Notes:1 Limited availability, please contact your local
American Electric Lighting representative2 Other colors available, please contact your local
American Electric Lighting representative3 T3 option only available with 240, 480, DT2, DT4, MT24 Not available in MT, TT, DT voltages5 PC, SH, not available in NR option6 Available in HPS only7 FG Optics only8 Tested to withstand 3G vibration, 4B option required9 Nighttime FriendlyTM opticRefer to accessory section for shield options
Optics
DistributionBallast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 54 for compatibility.
R2SG R3SG R2FG R3FG R2FGHP R3FGHP03S � � � � � �
05S � � � � � �
07S � � � � � �
10S � � � � � �
15S � � � � � �
20S � - � - - -25S � - � - - -40S � - � - - -17M � - �1 �1 - -25M � - �1 �1 - -
Optic Distribution
Notes:1 Use deluxe/coated lamp LD option
P R O D U C T O V E R V I E W
26 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Optional two-bolt mast arm mount provides easy, secure installation andadjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standardfour-bolt mounting provides extra security in high-vibration applications
Die-cast trigger latch on doorframe enables easy and secure one-handopening for re-lamping and maintenance
Large surface area "breathing seal" gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) with 2B optionand is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-2/8" O.D.) mast arms
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution with eitherborosilicate glass, or polycarbonate refractor
NEMA wattage label, terminal block, and NEMA photocontrol receptacle arestandard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul socket standard
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
Suitable for -30°C MH / -40°C HPS
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 125Roadway Lighting200-400W HPS, 175-400W MH
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire series 125 is 1.30 sq. ft.Approx. Wt. = 35 lbs.
PREFERRED SELECTION CATALOG NUMBERS
125 25S CA MT1 R3 DG EC125 40S CA MT1 R3 DG EC125 40M SC MT1 R3 DG
27Product Guide
Example: 1 2 5 4 0 S C A M T 1 R 3 D G L C P C
O R D E R I N G I N F O R M A T I O N
Roadway Series 125Roadway Lighting
200-400W HPS, 175-400W MH
125 Single DoorCobrahead
DP Drop PolycarbonatePrismatic Refractor
DG Drop GlassPrismatic Refractor
R2 Roadway Type IIR3 Roadway Type IIIR4 Roadway Type IV
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWA
MR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap Wired 480V2
17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 2501
24 250/400W Wired 4001
S HPSM MH
Mounting(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2” Setting2B 2-bolt Internal 1-1/4” Setting
Paint3
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation
(L1, N, L2 Position)4
ListingUL UL ListedCS CSA Certified
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle6
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter7
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified6
BL Bubble LevelSS Stainless Steel Fasteners (external)CF Charcoal FilterPL Distribution Pattern
Indicator LabelLA Lightning Arrestor
(Void UL/CSA Certified Options)5H 50 Hertz Ballast Cycle8
NN No NEMA Label on HousingSH Shorting Cap6
HK Hinge KeeperRG Rubber Silicone Optical Gasket
Notes:1 5-tap not available2 Available in 250W and 400W3 Other colors available, please contact your local
American Electric Lighting representative4 T3 option only available with 240, 480, DT2, DT4, MT25 Not available with MT, TT, DT voltages6 PC and SH not available in NR option7 Available in HPS only8 Limited availability, please contact your local
American Electric Lighting representative
Optics
DistributionBallast VoltageWattage / SourceSeries
R2DP R3DP R2DG R3DG R4DG20S � � � � �
25S � � � � �
31S � � � � �
40S � � � � �
17M � � - � -25M � � - � -40M � � � � -
Optic Distribution
Refer to the ballast matrix onpage 54 for compatibility.
P R O D U C T O V E R V I E W
28 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Optional two-bolt mast arm mount provides easy, secure installation andadjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standardfour-bolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on doorframe enables easy and secure one-handopening for re-lamping and maintenance
Large surface area “breathing seal” gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) with 2B optionand is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution with eitherflat or sag clear tempered glass
NEMA wattage label, terminal block, and photocontrol receptacle are standard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul socket standard
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 125Roadway Lighting — Cutoff Style200-400W HPS, 175-400W MH
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire series 125 Cutoff is 1.14 sq. ft.Approx. Wt. = 35 lbs
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 125 with sag glass is 1.22 sq. ft.
PREFERRED SELECTION CATALOG NUMBERS
125 25S CA MT1 R3 FG EC125 40S CA MT1 R3 FG EC
29Product Guide
Example: 1 2 5 4 0 S C A M T 1 R 3 F G L C P C
O R D E R I N G I N F O R M A T I O N
Roadway Series 125Roadway Lighting— Cutoff Style
200-400W HPS, 175-400W MH
125 Single DoorCobrahead
FG Flat Glass Clear Tempered10
SG Sag Glass Clear Tempered
R2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWA
MR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap Wired 480V2
17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 2501
24 250/400W Wired 4001
S HPSM MH
Mounting(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2” Setting2B 2-bolt Internal 1-1/4” Setting
Paint3
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation
(L1, N, L2 Position)4
ListingUL UL ListedCS CSA Certified
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle6
Options
LampLC Lamp Included, Clear LD Lamp Included, Deluxe/Coated
Starter7
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified6
BL Bubble LevelSS Stainless Steel Fasteners (external)CF Charcoal FilterPL Distribution Pattern
Indicator LabelLA Lightning Arrestor
(Void UL/CSA Certified Options)5H 50 Hertz Ballast Cycle9
SH Shorting Cap6
HK Hinge KeeperHP High Performance8
RG Rubber Silicone Optical Gasket
Optics
DistributionBallast VoltageWattage / SourceSeries
R2SG R3SG R2FG R3FG R2FGHP R2FGHP20S � � � � � �
25S � � � � � �
31S � � � � � �
40S � � � � � �
17M � � � � - -25M � � � � - -40M � � - - - -
Optic Distribution
Notes:1 Not available in 5-tap2 Available in 250W and 400W3 Other colors available, please contact your local
American Electric Lighting representative4 T3 option only available with 240, 480, DT2, DT4, MT25 Not available with MT, TT, DT voltages6 PC, SH, not available in NR option7 Available in HPS only8 FG Optics only9 Limited availability, please contact your local
American Electric Lighting representative10 Nighttime FriendlyTM optic
Refer to the ballast matrix onpage 54 for compatibility.
P R O D U C T O V E R V I E W
30 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Die-cast secondary Power Pad door places all electrical components on oneeasily interchangeable module with quick disconnects to main fixture housing.
Optional two-bolt mast arm mount provides easy, secure installation andadjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standardfour-bolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on lens frame enables easy and secure one-handopening for re-lamping.
Large surface area “breathing seal” gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) with 2B optionand is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms.
Photocontrol receptacle is adjustable without tools.
Anodized aluminum reflectors provide uniform lighting distribution with eitherborosilicate glass or polycarbonate refractor.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle arestandard.
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul socket standard
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 325Roadway Lighting — with Power Door200-400W HPS, 175-400W MH
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 325 is 1.30 sq. ft.Approx. Wt. = 35 lbs.
DIMENSIONS
PREFERRED SELECTION CATALOG NUMBERS
325 25S CA MT1 R3 DG EC325 40M SC MT1 R3 DG325 40S CA MT1 R3 DG EC325 40M SC 480 R3 DG
31Product Guide
Example: 3 2 5 4 0 M C A M T 7 R 3 D G B K L C
O R D E R I N G I N F O R M A T I O N
Roadway Series 325Roadway Lighting — with Power Door
200-400W HPS, 175-400W MH
325 Power DoorCobrahead
DP Drop PolycarbonatePrismatic Refractor
DG Drop GlassPrismatic Refractor
R2 Roadway Type IIR3 Roadway Type IIIR4 Roadway Type IV
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWISC SCWA
MR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap wired 480V2
17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 250W1
24 250/400WWired 400W1
S HPSM MH
Mounting(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2” Setting2B 2-bolt Internal 1-1/4” Setting
Paint3
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation
(L1, N, L2 Position)4
ListingUL UL ListedCS CSA Certified
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle6
Options
LampLC Lamp Included, ClearLD Lamp Included Deluxe/Coated
Starter7
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified6
BL Bubble LevelSS Stainless Steel Fasteners (external)CF Charcoal FilterPL Distribution Pattern
Indicator LabelLA Lightning Arrestor
(Void UL/CSA Certified Options)5H 50 Hertz Ballast Cycle8
SH Shorting Cap6
HK Hinge KeeperRG Rubber Silicone Optical GasketTL Tool-less Entry to Power Pad
Notes:1 Not available in 5-tap2 Available in 250W and 400W3 Other colors available, please contact your local
American Electric Lighting representative4 T3 option only available with 240, 480, DT2, DT4, MT25 Not available with MT, TT, DT voltages6 PC and SH, not available in NR option7 Available in HPS only8 Limited availability, please contact your local
American Electric Lighting representative
Optics
DistributionBallast VoltageWattage / SourceSeries
R2DP R3DP R2DG R3DG R4DG20S � � � � �
25S � � � � �
31S � � � � �
40S � � � � �
17M � � - � -25M � � - � -40M � � � � -
Optic Distribution
Refer to the ballast matrix onpage 55 for compatibility.
P R O D U C T O V E R V I E W
32 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Die-cast secondary Power Pad door places all electrical components on oneeasily interchangeable module with quick disconnects to main fixture housing.
Optional two-bolt mast arm mount provides easy, secure installation andadjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standardfour-bolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on lens frame enables easy and secure one-handopening for re-lamping.
Large surface area “breathing seal” gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) with 2B optionand is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms.
Photocontrol receptacle is adjustable without tools.
Anodized aluminum reflectors provide uniform lighting distribution with eitherflat or sag clear tempered glass.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle arestandard.
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul socket standard
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 325Roadway Lighting — Cutoff Style with Power Door200-400W HPS, 175-400W MH
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 325 is 1.14 sq. ft.Approx. Wt. = 35 lbs
Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 325 with sag glass is 1.22 sq. ft.
PREFERRED SELECTION CATALOG NUMBERS
325 25S CA MT1 R3 FG EC325 40S CA MT1 R3 FG EC
33Product Guide
Example: 3 2 5 3 1 S C A M T 1 R 3 F G S F B L
O R D E R I N G I N F O R M A T I O N
Roadway Series 325Roadway Lighting — Cutoff Style with Power Door
200-400W HPS, 175-400W MH
325 Power DoorCobrahead
FG Flat Glass Clear Tempered9
SG Sag Glass Clear Tempered
R2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWACT CWI
MR Mag Reg (3 Coil)SC SCWA
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T1 5-tap Wired 120V8
5T2 5-tap Wired 240V8
5T7 5-tap Wired 277V8
5T4 5-tap Wired 480V8
17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 250W1
24 250/400WWired 400W1
S HPSM MH
Mounting(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2” Setting2B 2-bolt Internal 1-1/4” Setting
Paint2
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation
(L1, N, L2 Position)3
ListingUL UL ListedCS CSA Certified
Fusing4
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle5
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter6
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified5
BL Bubble LevelSS Stainless Steel Fasteners (external)CF Charcoal FilterPL Distribution Pattern
Indicator LabelLA Lightning Arrestor
(Void UL/CSA Certified Options)5H 50 Hertz Ballast Cycle8
SH Shorting Cap5
HK Hinge KeeperHP High Performance7
TL Tool-less Entry to Power Pad
Notes:1 Not available in 5-tap2 Other colors available, please contact your local
American Electric Lighting representative3 T3 option only available with 240, 480, DT2, DT4, MT24 Not available with MT, TT, DT voltages5 PC and SH, not available in NR option6 Available in HPS only7 Available with FG optics only8 Limited availability, please contact your local
American Electric Lighting representative9 Nighttime FriendlyTM optic
Optics
DistributionBallast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 55 for compatibility.
R2SG R3SG R2FG R3FG R2FGHP R2FGHP20S � � � � � �
25S � � � � � �
31S � � � � � �
40S � � � � � �
17M - - � � - -25M - - � � - -40M � � - - - -
Optic Distribution
P R O D U C T O V E R V I E W
34 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Four-bolt mast arm mount provides easy, secure installation and adjustabilityfor arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter and extra security inhigh-vibration applications.
Die-cast trigger latch on doorframe enables easy and secure one-handopening for re-lamping and maintenance
Large surface area “breathing seal” gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistantgasket material remains effective over the life of the fixture.
Anodized aluminum reflectors provide uniform lighting distribution withstandard borosilicate glass refractor.
Photocontrol receptacle is adjustable without tools
NEMA wattage label, terminal block, and NEMA photocontrol receptacle arestandard.
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul socket standard
Complies with ANSI: C136.2, C136.10, C136.14, C136.15
Suitable for -30°C MH / -40°C HPS
Applications:RoadwaysResidential streetsStorage areasParking lotsCampusesParks
Roadway Series 327Roadway Lighting1000W HPS, 1000W MH
Effective Projected Area (EPA)The EPA for the Horizontal Luminaire Series 327 is 1.96 sq. ft.Approx. Wt. = 60 lbs
16-1/4"(413)
16-1/4"(413)
17-1/2"(445)
38.3"(973)
PREFERRED SELECTION CATALOG NUMBERS
327 X1S CA MT1 R3 DG327 X1M CA MT1 R3 DG
35Product Guide
Example: 3 2 7 X 1 M C A M T 1 R 3 D G L C P C
O R D E R I N G I N F O R M A T I O N
Roadway Series 327Roadway Lighting
1000W HPS, 1000W MH
327 Single DoorCobrahead
DG Drop GlassPrismatic Refractor
R1 Roadway Type IR2 Roadway Type IIR3 Roadway Type III
Refer to optic distributionmatrix below for compatibility.
CA CWASC SCWA
120 120V208 208V240 240V277 277V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277V5T4 5-tap Wired 480V1
X1 1000W S HPSM MH
Paint2
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation
(L1, N, L2 Position)3
Fusing4
SF Single Fuse (120, 277V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle5
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Misc.PC Photocontrol Included per
Voltage Specified5
BL Bubble LevelSS Stainless Steel Fasteners (external)PL Distribution Pattern
Indicator LabelLA Lightning ArrestorSH Shorting Cap5
Notes:1 Limited availability, please contact your local
American Lighting representative2 Other colors available, please contact your local
American Electric Lighting representative3 T3 option only available with 240, 480, DT2, DT4, MT24 Not available with MT voltages5 PC and SH not available with NR option
Optics
DistributionBallast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 55 for compatibility.
R1DG R2DG R3DGX1S - - �
X1M � � �
Optic Distribution
P R O D U C T O V E R V I E W
36 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:Unique optical design allows set-back of mounting poles away from trafficareas, while still delivering superior performance.
Light pattern allows exceptional spacing to mounting height ratios, permittingfewer luminaries per mile
Anodized aluminum reflector provides uniform lighting distribution with dropacrylic prismatic refractor.
Adjustable and locking knuckle mount provides for precise and secure aimingof the luminaire
Suitable for 2-3/8” to 3” O.D. tenons
Latch on lens frame enables easy and secure one-handed opening for re-lamping
Photocontrol receptacle is adjustable without tools
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Applications:Interstate roadwaysBroad commercial and residential roadwaysLarge parking areas
Roadway Series 285Roadway Lighting — Set-Back200-400W HPS, 250-400W MH
Effective Projected Area (EPA)The EPA for the MultiMount™ Luminaire Series 285 is 2.8 sq. ft.Approx Wt. = 42 lbs
PREFERRED SELECTION CATALOG NUMBERS
285 25S CA MT1 R3 DA GY285 40S CA MT1 R3 DA GY
37Product Guide
Example: 2 8 5 4 0 S C A M T 1 R 3 D A L C
O R D E R I N G I N F O R M A T I O N
Roadway Series 285Roadway Lighting — Set-Back
200-400W HPS, 250-400W MH
285 Multi-Mount Roadway
20 200W25 250W31 310W 40 400W1
23 250/400W Wired 250
24 250/400W Wired 4001 Optics
DistributionBallastWattage / SourceSeries
R3 Roadway Type III2
RN Reactor Normal Power FactorRH Reactor High Power FactorXN High Reactance (Lag)
Normal Power FactorXH High Reactance (Lag)
High Power FactorCA CWACT CWISC SCWA
MR Mag Reg (3 Coil)
S HPSM MH
DA Drop Acrylic Prismatic Refractor
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240 Wired 240VDT4 Dual Tap 240/480 Wired 480V
Paint3
(blank) Bronze (standard)BK Black
WH WhiteUP UnpaintedGY Gray
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 and L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)4
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle6
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter7
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included
per Voltage Specified6
HK Hinge KeeperSS Stainless Steel Fasteners (external)PL Distribution Pattern Indicator LabelLA Lightning ArrestorNL NEMA LabelSH Shorting Cap6
Notes:
1 400 MH requires reduced jacket ED-28 lamp2 Distribution depends on tilt angle of fixture3 Other colors available, please contact your local
American Electric Lighting representative4 T3 option only available with 240, 480, DT2, DT4, MT25 Not available with MT, TT, DT voltages6 PC and SH not available with NR option7 For HPS only
Refer to the ballast matrix onpage 56 for compatibility.
P R O D U C T O V E R V I E W
38 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Applications:Interstate roadwaysExpresswaysRailway switchyardsShipping docksLarge parking lots
InterState™ II Series 775Roadway Lighting — Interstate with Contemporary Style200-400W HPS, 175-400W MH
19.5"(495)
.44" (11) Dia.
.78" (20) Dia.
1" (25)
2" (51)
1" (25)
2" (51)Effective Projected Area (EPA)The EPA for the InterState™ II is 2.75 sq. ft.Approx. Wt. = 37 lbs
Vertical Tenon Mount
Yoke Mount
Features:Unique optical design allows set-back of mounting poles away from trafficareas, while still delivering superior performance
Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Slim profile provides a low EPA
Door is hinged and easily removable for quick maintenance
Anodized aluminum reflector provides uniform lighting distribution with sag orflat glass clear tempered refractor
Adjustable and locking knuckle mount provides for precise and secure aimingof the luminaire
Suitable for 2-3/8” to 3” O.D. tenons
Photocontrol receptacle is adjustable without tools
For fast relamping optional tool-less access is available
NEMA wattage label, terminal block, and NEMA photocontrol receptacle arestandard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.3, C136.10, C136.15, C136.31
PREFERRED SELECTION CATALOG NUMBERS
775 25S CA MT1 R3 FG775 25S CA MT1 R3 SG775 40M SC MT1 R3 SG775 40S CA MT1 R3 SG
39Product Guide
Example: 7 7 5 4 0 S C A 4 8 0 R 3 S G
O R D E R I N G I N F O R M A T I O N
InterState™ II Series 775Roadway Lighting — Interstate with Contemporary Style
200-400W HPS, 175-400W MH
775 InterState RoadwayOffset
17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 250W1
24 250/400WWired 400W1 Optics
BallastWattage / Source Series
RN Reactor Normal Power FactorRH Reactor High Power FactorXN High Reactance (Lag)
Normal Power FactorXH High Reactance (Lag)
High Power FactorCA CWACT CWI
MR Mag Reg (3 Coil)SC SCWA2
S HPSM MH
SG Sag GlassClear Tempered
FG Flat GlassClear Tempered
DistributionVoltage
R3 RoadwayType III4
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap Wired 480V3
Mounting(blank) Tenon Slipfitter (standard)4
YG Yoke GalvanizedYP Yoke Painted5
Paint6
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 and L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)7
Standard Listing(blank) UL Listed (standard)
CS CSA Certified
Fusing8
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480V)
Options
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle9
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter10
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included
per Voltage Specified9
TL Tool-less EntrySS Stainless Steel Fasteners (external)PL Distribution Pattern Indicator LabelLA Lightning Arrestor 5H 50 Hertz Ballast Cycle2
SH Shorting Cap9
Notes:
1 Not available in 5-tap2 Limited availability, please contact your local
American Electric Lighting representative3 250W and 400W only4 Distribution depends on tilt angle of fixture5 Painted to match specified color of fixture6 Other colors available, please contact your local
American Electric Lighting representative7 T3 option only available with 240, 480, DT2, DT4, MT28 Not available with MT, TT, DT voltages9 PC, SH not available with NR option
10 For HPS Products only
Refer to the ballast matrix onpage 56 for compatibility.
P R O D U C T O V E R V I E W
40 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
P R O D U C T O V E R V I E W
7-1/2"(191)
9"(229)
4-1/2"(114)
4"(102)
27"(686)
DIMENSIONS
Features:Designed for maximum energy savings with efficient light distribution
Vandal resistant, rugged and corrosion resistant die cast aluminum housing
Drop polycarbonate prismatic refractor allows for maximum control of lightdistribution
Large surface area "breathing seal," gasket seals the optical chamber toprevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture.
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10
Applications:RoadwaysHighwaysTransportation terminals
LPS Roadway Series SRXRoadway Lighting35-90W LPS
Effective Projected Area (EPA)The EPA for the Roadway Luminaire Series SRX is 1.00 sq. ft.Approx. Wt. = 20 lbs.
PREFERRED SELECTION CATALOG NUMBERS
SRX 55L XH DT1 R4 DP LCSRX 55L XH 480 R4 DP NR
41Product Guide
O R D E R I N G I N F O R M A T I O N
Example: S R X 0 9 L R H 4 8 0 R 4 D P L C
LPS Roadway Series SRXRoadway Lighting
35-90W LPS
SRX Low Pressure Sodium Roadway
03 35W 55 55W09 90W
Optics
DistributionBallast VoltageWattage / SourceSeries
R4 Roadway Type IV
120 120V208 208V240 240V277 277V347 347V480 480V
DT1 Dual Tap 120/240 Wired 120V
DT2 Dual Tap 120/240 Wired 240V
DT5 Dual Tap 208/277 Wired 208V
DT6 Dual Tap 208/277 Wired 277V
RH Reactor High Power Factor
XH High Reactance (Lag) High Power Factor
L LPS
DP Drop PolycarbonatePrismatic Refractor
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle (standard)
NR No Photocontrol Receptacle1
LampLC Lamp Included, Clear
ListingUL UL Listed
Misc.PC Photocontrol Included per Voltage Specified1
SH Shorting Cap1
Options
Refer to the ballast matrix onpage 57 for compatibility.
Notes:1 PC and SH not available with NR option
P R O D U C T O V E R V I E W
42 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Designed for maximum energy savings with efficient light distribution
Outside housing constructed of non-corrosive ABS plastic with UVinhibiting coating
Drop acrylic or polycarbonate prismatic refractor allows for maximumcontrol of light distribution
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Applications:RoadwaysHighwaysSecurity lightingTransportation terminals
LPS Roadway Series SP2Roadway Lighting90-180W LPS
SERIES LENGTH (L) EPA (Sq. Ft.)
SP290 397/16'' 1.00
SP213 497/16'' 1.20
SP218 637/16'' 1.45
DIMENSIONS
Approx. Wt. = 31 lbs
PREFERRED SELECTION CATALOG NUMBERS
SP2 09L XH DT1 R4 DP LCSP2 13L XH DT1 R4 DP LCSP2 18L XH DT1 R4 DP LC
43Product Guide
Example: S P 2 1 8 L X H 4 8 0 R 4 D P L C
O R D E R I N G I N F O R M A T I O N
LPS Roadway Series SP2Roadway Lighting
90-180W LPS
SP2 Low PressureSodium Roadway
09 90W13 135W18 180W
Optics
DistributionBallast VoltageWattage / SourceSeries
R4 Roadway Type IV
120 120V208 208V240 240V277 277V347 347V480 480V
DT1 Dual Tap Wired120/240 Wired 120V
DT2 Dual Tap Wired 120/240 Wired 240V
DT5 Dual Tap 208/277 Wired 208V
DT6 Dual Tap 208/277 Wired 277V
RH Reactor HighPower Factor
XH High Reactance (Lag) High Power Factor
L LPS
DA Drop AcrylicPrismatic Refractor
DP Drop Polycarbonate Prismatic Refractor
Options
ListingUL UL ListedCS CSA Certified
Photocontrol Receptacle(blank) With Photocontrol Receptacle
NR No Photocontrol Receptacle1
LampLC Lamp Included, Clear
Misc.PC Photocontrol Included per Voltage 1SH Shorting Cap1
Notes:1 PC and SH not available with NR option
Refer to the ballast matrix onpage 57 for compatibility.
P R O D U C T O V E R V I E W
44 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Low profile design for unobtrusive surface mounting
Die-cast aluminum back housing with choice of die-cast front housing withborosilicate glass lens, or one-piece polycarbonate front housing and lens
Designed for easy access to electrical compartment and optical assemblyfor installation and maintenance ease
All exterior hardware is captive
UL and CSA listed for wet locations
All electrical components warranted by American Electric Lighting's 6-yearguarantee
E39 mogul socket standard
Suitable for -30°C MH / -40°C HPS
Applications:Office complexesShopping centers and mallsSchools and hospitalsParking garagesTunnel and underpassesParks
Underpass Series 581/681Roadway Lighting50-250W HPS, 175-250W MH
DIMENSIONS
Approx. Wt. = 30 lbs
PREFERRED SELECTION CATALOG NUMBERS
581 15S CA 120581 15M XN MT1681 10S RN 120681 15S RN 120681 15M XN MT1
45Product Guide
Example: 5 8 1 2 5 S C A M T 1 G Y
O R D E R I N G I N F O R M A T I O N
Underpass Series 581/681Roadway Lighting
50-250W HPS, 175-250W MH
581 Wallpack w/Die-cast andGlass Fronthousing
681 Wallpack w/PolycarbonateFront Housing1
05 50 W07 70 W10 100 W15 150 W17 175 W20 200 W25 250 W
BallastWattage / SourceSeries
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) Normal Power Factor
XH High Reactance (Lag) High Power Factor
CA CWACT CWI
S HPSM MH
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240 Wired 240VDT4 Dual Tap 240/480 Wired 480V
Mounting(blank) Wall Mount (standard)
Paint2
(blank) Bronze (standard)BK Black
WH WhiteGY GrayUP Unpainted
Listing(blank) UL Listing (standard)
CS CSA Certified
Fusing3
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480V)
Options
Photocontrol Receptacle(blank) Button Control (standard)
(multi-volt options not available)NC No Photocontrol
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Misc.SE Side EntrySS Stainless Steel Fasteners (external)5H 50 Hertz Ballast Cycle4
NL NEMA Label
Notes:1 Max Wattage 175W, only available in bronze2 Other colors available, please contact your local
American Electric Lighting representative3 Not available with MT, TT, DT voltages4 Limited availability, please contact your local
American Electric Lighting representative
Refer to the ballast matrix onpage 57 for compatibility.
P R O D U C T O V E R V I E W
46 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Designed for easy access to electrical compartment and optical assemblyfor installation and maintenance ease
Heavy duty, two piece, die cast aluminum housing with hinged, captivebezel and corrosion resistant hardware
Completely sealed with high temperature silicone gasket
High impact and heat resistant borosilicate glass refractor
One piece, stippled, asymmetric anodized aluminum reflector designed toproduce a wide pattern of efficient illumination
UL and CSA certified for wet locations
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPS
Applications:Parking areasPerimeter lightingEntrances and walkwaysWaterfront areasLoading platformsRecreational areas
Heavy Duty Wallpack Series 882Roadway Lighting — Building Mounted200-400W HPS, 175-400W MH
DIMENSIONS
Approx. Wt. = 36 lbs
PREFERRED SELECTION CATALOG NUMBERS
882 25S CA MT7882 40M CA 5T4
47Product Guide
Example: 8 8 2 2 5 S C A M T 1
O R D E R I N G I N F O R M A T I O N
Heavy Duty Wallpack Series 882Roadway Lighting — Building Mounted
200-400W HPS, 175-400W MH
882 Wallpack CA CWACT CWI
MR Mag Reg
480 480VMT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VMT8 Multi tap Wired 208V5T4 5-tap Wired 480V
17 175W20 200W25 250W31 310W40 400W
S HPSM MH
Listing(blank) UL Listed (standard)
CS CSA Certified
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Ballast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 58 for compatibility.
P R O D U C T O V E R V I E W
48 Product Guide
Features:Die cast low copper aluminum housing offers light weight and corrosionresistance with excellent durability
Hinged door is easily removable for quick maintenance, tool-less optionmakes relamping easy
Anodized aluminum reflector provides uniform lighting distribution with sagor flat clear tempered glass lens
Rotatable optics
UL listed for wet locations
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.15
Applications:Interstate highwaysOutdoor advertising signsTraffic flow signsBuilding facadesSecurity lightingCorporate and building lightingOther vertical surfaces, watts
SignLite Series 875Roadway Lighting — Sign Light175-400W MH, 200-400W HPS
Effective Projected Area (EPA)The EPA for the Signlite Luminaire, Series 875 is 2.75 sq. ft.Approx. Wt. = 37 lbs
For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
19.5"(495)
.44" (11) Dia.
.78" (20) Dia.
1" (25)
2" (51)
1" (25)
2" (51)
Yoke Mount
Vertical Tenon Mount
PREFERRED SELECTION CATALOG NUMBERS
875 25M SC 120 56 SG
49Product Guide
O R D E R I N G I N F O R M A T I O N
Example: 8 7 5 4 0 M C A 4 8 0 6 6 S G
SignLite Series 875Roadway Lighting — Sign Light
175-400W MH, 200-400W HPS
875 Sign Light 17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 250W1
24 250/400WWired 400W1
Optics
Distribution3BallastWattage / SourceSeries
56 5H X 6V NEMA distribution
66 6H X 6V NEMA distribution
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance / Lag Normal Power Factor
XH High Reactance / Lag High Power Factor
CA CWA Auto RegCT CWI
MR Mag Reg (3 Coil)SC SCWA
S HPSM MH
SG Sag GlassClear Tempered
FG Flat GlassClear Tempered
Notes:
1 Not available in 5-tap2 250W and 400W only3 Distribution depends on tilt angle of fixture4 Painted to match specified color of fixture5 Other colors available, please contact
your local American Electric Lightingrepresentative
6 T3 option only available with 240, 480, DT2, DT4, MT27 Not available with MT, TT, DT voltages8 PC, and SH not available with NR option9 Available in HPS only
10 Limited availability, please contact your local American Electric Lighting representative
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240 Wired 240VDT4 Dual Tap 240/480 Wired 480V5T4 5-tap Wired 480V2
Mounting(blank) Tenon Mount (standard)4
YG Yoke GalvanizedYP Yoke Painted3
Paint5
(blank) Gray (standard)BK BlackBZ Bronze
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 and L2 PositionT3 3 Wire Operation (L1, N, L2
Position)6
Listing(blank) UL Listed (standard)
CS CSA Certified
Fusing7
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480V)
Options
Photocontrol Receptacle(blank) Photocontrol Receptacle (standard)
NR No Photocontrol Receptacle8
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter9
EC Encapsulated Plug-inOP Open Plug-in
Misc.TL Tool-less EntryBT Ballast TraySS Stainless Steel Fasteners (external)CF Charcoal FilterLA Lightning Arrestor
(Void UL/CSA Listed Options)PC Photocontrol Included per
Voltage Specified8
5H 50 Hertz Ballast Cycle10
NL NEMA LabelSH Shorting Cap8
Refer to the ballast matrix onpage 58 for compatibility.
A V A I L A B I L I T Y
50 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Accessories
NOTES:1 Polycarbonate Vandal shield and Wireguard can not be used simultaneously2 250W lamp maximum3 400W lamp maximum
Description Catalog Number
SERIES 115 GLARE SHIELD RK115 GS
HOUSE SIDE SHIELD FOR FLAT/SAG GLASS 115 HS SHLD EXTERNAL FG/SGHOUSE SIDE SHIELD FOR DROP GLASS 115 HS SHLD EXTERNAL DGHOUSE SIDE SHIELD FOR FLAT/SAG GLASS 315 HS SHLD EXTERNAL FG/SGHOUSE SIDE SHIELD FOR DROP GLASS 315 HS SHLD EXTERNAL DGHOUSE SIDE SHIELD FOR FLAT/SAG GLASS 125 HS SHLD EXTERNAL FG/SGHOUSE SIDE SHIELD FOR DROP GLASS 125 HS SHLD EXTERNAL DGHOUSE SIDE SHIELD FOR FLAT/SAG GLASS 325 HS SHLD EXTERNAL FG/SGHOUSE SIDE SHIELD FOR DROP GLASS 325 HS SHLD EXTERNAL DG
POLYCARBONATE SHIELD RK581 VSFOR SIDELITE 581
115 315 125 325 581/681 882Glare Shield RK115 GS - RK125-GS -- -House Side Shield, Cutoff 115 HS SHLD EXTERNAL FG/SG 315 HS SHLD EXTERNAL FG/SG 125 HS SHLD EXTERNAL FG/SG 325 HS SHLD EXTERNAL FG/SG - -House Side Shield, Drop 115 HS SHLD EXTERNAL DG 315 HS SHLD EXTERNAL DG 125 HS SHLD EXTERNAL DG 325 HS SHLD EXTERNAL DG - -Polycarbonate Vandal Shield1 - - - - RK581 VS -Ballistic Shield for Flat Lens 115 PGS FL 25W2 315 PGS FL 25W2 125 PGS FL 40W3 325 PGS FL 40W3 - -Ballistic Shield for Flat Lens with Side Protection 115 PGS FL 25W SPS2 315 PGS FL 25W SPS2 - - - -Ballistic Shield for Drop Lens 115 PGS DL 25W2 315 PGS DL 25W2 125 PGS DL 40W3 325 PGS DL 40W3 - -Wireguard1 - - - - RK581/681 WG RK882 WG
51Product Guide
S H I E L D S / W I R E G U A R D S
Description Catalog Number
RK115 or 315 PGS FL 25WRK115 or 315 PGS FL 25W SPS
BALLISTIC SHIELDS RK115 or 315 PGS DL 25WRK115 or 315 PGS DL 25W SPSRK125 or 325 PGS FL 40WRK125 or 325 PGS DL 40W
WIRE GUARDS RK581/681 WGRK882 WG
Accessories
6.50"(194)
16.63"(422)
6.25"(159)
17"(432)
6.50"(165)
8.67"(220)
B A L L A S T M A T R I C E S
52 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Corvus CVM
Corvus CVM continued
DuraStar Series 20
Watts MT1 MT2 MT7 TT305S - - - -07S XN,XH XN,XH XN,XH XN,XH10S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XN,XH15S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XN,XH17M CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA
Watts 120 208 240 277 480 DT2 DT405S RH,RN - - XN - - -07S CA,CT,RN,RH,XN,XH CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN CA CA10S CA,CT,RN,RH,XN,XH CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,XN,XH CA,CT,XH -15S CA,CT,RN,RH,XN,XH CA,CT,XH,XN CA,CT,RN,RH,XN,XH CA,CT,XH,XN CA,CT CA,CT,XH,XN -17M CA,CT CA,CT, CA,CT CA,CT CA,CT CA,CT -
DuraStar Series 20 continued
Roadway Lighting
Watts 120 208 240 277 347 480 DT2 DT407S CA,CT,MR,RH,RN XH,CA,XN CA,MR,XH,XN XH,CA,CT,XN XH,XN XH,XN CA,CT,MR,XH,XN MR10S CA,CT,MR,RH,RN CA,CT,XN,XH CA,CT,MR,XH,XN CA,XH,XN CT,XH,XN CA,CT,XN CA,CT,MR,XH,XN -15S CA,CT,MR,RH,RN CA,CT,XN,XH CA,CT,MR,XH,XN XN,XH,CA,CT CA, CT,XH,XN CA,MR,XN,XH CA,CT,MR,XH,XN MR13S RN,RH - - - - - - -14S RN,RH - - - - - - -17M CA CA CA CA CA CA CA -20S CA,CT,XN,XH CA,CT CA,XN,XH CA,CT - CA,CT CA,CT,XN,XH -25S CA,CT,XN,XH CA,CT CA,CT,XN,XH CA,CT CA CA CA,CT,XN,XH -25M CA,CT CA CA,CT CA,CT CA,CT CA,CT CA,CT CT40S - RN,RH RN,RH - - - -
Watts MT1 MT2 MT7 TT307S CA,XH,XN CA,XH,XN CA,XH,XN CT,XH,XN10S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XN,XH CT,XH,XN15S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN13S - - - -14S - - - -17M CA CA CA CA20S CA,CT CA,CT CA,CT -25S CA,CT CA,CT CA,CT CA,CT25M CA CA CA CA,CT40S - - - -
Corvus CVLWatts 120 208 240 277 347 480 DT2 DT417M CA CA CA CA CA CA CA -20S CA,CT,MR,XN,XH CA, CT CA,CT,RN,RH,MR CA,CT - CA,CT,MR CA,CT,MR,XN,XH -25S CA,CT,MR,XN,XH CA,CT,MR CA,CT,RN,RH,MR CA,CT,MR CA CA,MR XN,XH,MR MR25M CA,CT,SC CA,SC CA,CT,SC CA,SC CA,CT,SC CA,CT CA,CT,SC -31S CA,MR CA CA,MR CA - CA,MR CA,MR MR40S CA,CT,MR,XN,XH CA,CT,MR,RN,RH CA,CT,MR,RN,RH, CA,CT,MR CA CA,MR CA,CT,MR,XN,XH MR40M CA,CT,SC CA,CT,SC CA,CT,SC CA,SC CA,CT,SC CA CA,CT CT23/24S CA,CT, CA,CT, CA,CT CA,CT - CA CA,CT -23/24M CA CA CA CA - CA CA -
Watts MT1 MT2 MT7 TT3 5T417M CA CA CA CA -20S CT,CA CT,CA CT,CA - -25S CA,CT,MR CA,CT,MR CA,CT CA,CT CA25M CA,SC CA,SC CA,SC CA,CT,SC CA31S CA CA CA - -40S CA,CT,MR CA,CT,MR CA,CT CA CA40M CA,SC CA,SC CA,SC CA,CT,SC CA23/24S CA,CT CA,CT CA,CT - -23/24M CA CA CA - -
Corvus CVL continued
53Product Guide
B A L L A S T M A T R I C E S
DuraStar Series 30Watts 120 208 240 277 347 480 DT2 5T417M CA CA,CT CA CA CA CA CA,CT -20S CA,CT,MR,XH,XN CA,CT CA,CT,MR,XH,XN CA,CT - CA,CT CA,CT,MR,XH,XN -25S CA,CT,MR,XH,XN CA,CT CA,CT,MR,XH,XN CA,CT CA CA,MR CA,CT,MR,XH,XN CA25M CA,CT,SC CA,SC CA,CT,SC CA,SC - CA,SC CA CA31S CA,MR CA,MR CA,MR MR,CA - CA,MR CA,MR -40S CA,CT,MR,XH,XN CA,CT,RH,RN CA,CT,MR,XH,XN,RH,RN CA,CT CA CA,MR MR CA40M CA,CT,SC CA,SC CA,CT,SC SC,CA,CT CA,CT,SC CA,CT CA,CT,SC CA23/24S CA CA CA CA - - CA -23/24M CA CA CA CA - - CA -
Watts DT4 MT1 MT2 MT7 TT317M - CA CA CA -20S - CA,CT CA,CT CA,CT -25S MR CA,CT CA,CT CA,CT -25M - CA,SC CA,SC CA,SC CA31S - CA CA CA CA40S MR CA,CT CA,CT CA,CT -40M - SC,CA SC,CA CA,SC CA23/24S - CA CA - CA23/24M - CA CA CA -
DuraStar Series 30 continued
Roadway 115Watts 120 208 240 277 347 480 DT2 DT403S RN - - - - - - -05S RH,RN - - XN - - - -07S CA,CT,MR,RH,RN XH,CA,XN CA,MR,XH,XN XH,CA,CT,XN XH,XN XH,XN CA,CT,MR,XH,XN MR10S CA,CT,MR,RH,RN CA,CT,XN,XH CA,CT,MR,XH,XN CA,XH,XN CT,XH,XN CA,CT,XN CA,CT,MR,XH,XN -15S CA,CT,MR,RH,RN CA,CT,XN,XH CA,CT,MR,XH,XN XN,XH,CA,CT CA, CT,XH,XN CA,MR,XN,XH CA,CT,MR,XH,XN MR13S RN,RH - - - - - - -14S RN,RH - - - - - - -17M CA CA CA CA CA CA CA -20S CA,CT,XN,XH CA,CT CA,XN,XH CA,CT - CA,CT CA,CT,XN,XH -25S CA,CT,XN,XH CA,CT CA,CT,XN,XH CA,CT CA CA CA,CT,XN,XH -25M CA,CT CA CA,CT CA,CT CA,CT CA,CT CA,CT CT40S - RN,RH RN,RH - - - -
Roadway 115 continuedWatts MT1 MT2 MT7 TT303S - - - -05S - - - -07S CA,XH,XN CA,XH,XN CA,XH,XN CT,XH,XN10S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XN,XH CT,XH,XN15S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN13S - - - -14S - - - -17M CA CA CA CA20S CA,CT CA,CT CA,CT -25S CA,CT CA,CT CA,CT CA,CT25M CA CA CA CA,CT40S - - - -
Roadway Lighting
B A L L A S T M A T R I C E S
54 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Roadway 125Watts 120 208 240 277 347 480 DT2 DT417M CA CA CA CA CA CA CA -20S CA,CT,MR,XN,XH CA, CT CA,CT,RN,RH,MR CA,CT - CA,CT,MR CA,CT,MR,XN,XH -25S CA,CT,MR,XN,XH CA,CT,MR CA,CT,RN,RH,MR CA,CT,MR CA CA,MR XN,XH,MR MR25M CA,CT,SC CA,SC CA,CT,SC CA,SC CA,CT,SC CA,CT CA,CT,SC -31S CA,MR CA CA,MR CA - CA,MR CA,MR MR40S CA,CT,MR,XN,XH CA,CT,MR,RN,RH CA,CT,MR,RN,RH, CA,CT,MR CA CA,MR CA,CT,MR,XN,XH MR40M CA,CT,SC CA,CT,SC CA,CT,SC CA,SC CA,CT,SC CA CA,CT CT23/24S CA,CT, CA,CT, CA,CT CA,CT - CA CA,CT -23/24M CA CA CA CA - CA CA -
Watts MT1 MT2 MT7 TT3 5T417M CA CA CA CA -20S CT,CA CT,CA CT,CA - -25S CA,CT,MR CA,CT,MR CA,CT CA,CT CA25M CA,SC CA,SC CA,SC CA,CT,SC CA31S CA CA CA - -40S CA,CT,MR CA,CT,MR CA,CT CA CA40M CA,SC CA,SC CA,SC CA,CT,SC CA23/24S CA,CT CA,CT CA,CT - -23/24M CA CA CA - -
Roadway 125 continued
Roadway 315Watts 120 208 240 277 480 DT203S RN - - - - -05S RH,RN - - XN - XH,XN 07S CA,CT,MR,RH,RN CA,XH,XN CA,MR,XH,XN XH,CA,CT,XN XH,XN CA,CT,MR,XH,XN10S CA,CT,MR,RH,RN CA,CT,XH,XN CA,CT,MR,XH,XN CA,CT,XH,XN CA,CT,MR,XH,XN CA,CT,MR,XH,XN15S CA,CT,MR,RH,RN CA,CT,XH,XN CA,CT,MR,XH,XN XH,CA,XN CA,CT,MR,XH,XN CA,CT,MR,XH,XN13S RN,RH - - - - -14S RN,RH - - - - -17M CA CA CA CA CA CA20S CA,CT,XH,XN CA,CT CA,CT,RH,RN,XH,XN CA,CT CA,CT CA,CT,XH,XN25S CA,CT,XH,XN CA,CT CA,CT,RH,RN CA,CT CA CA,CT,XH,XN25M CA,CT,SC CA,SC CA,CT,SC CA,CT,SC CA,CT,SC CA,CT,SC40S CA,XH,XN CA CA,RH,RN - CA -
Watts DT4 MT1 MT2 MT7 TT3 34703S - - - - - -05S - - - - - -07S - XH,XN,CA CA, XN,XH CA, XN,XH CT,XN,XH XN,XH10S - CA,CT,XN,XH CA,CT,XN,XH CA,CT,XN,XH CT,XN,XH CT,XN,XH15S MR CA,CT,XN,XH CA,CT,XN,XH CA,CT,XN,XH XN,XH XN,XH13S - - - - - -14S - - - - - -17M - CA CA CA CA CA20S - CA,CT CA,CT CA,CT - -25S - CA,CT,SC CA,CT,SC CA,CT,SC CA,CT CA25M - CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC40S - CA,XN,XH CA,XN,XH CA,XN,XH - -
Roadway 315 continued
Roadway Lighting
55Product Guide
B A L L A S T M A T R I C E S
Roadway 325
Roadway 325 continued
Roadway 327Watts 120 208 240 277 480 MT1 MT2 MT7 5T4X1S CA,CT CA,CT CA,CT CA,CT CA,CT CA CA CA CAX1M CA CS CA,SC CA CA CA CA CA XA
Roadway Lighting
Watts 120 208 240 277 347 480 DT2 DT417M CA CA CA CA CA CA CA -20S CA,CT,MR,XH,XN CA, CT CA,CT,MR,RN,RH CA,CT - CA,CT,MR CA,CT,MR,XH,XN -25S CA,CT,MR,XH,XN CA,CT,MR CA,CT,MR,RN,RH CA,CT,MR CA CA,MR XN,XH,MR MR25M CA,CT,SC CA,SC CA,CT,SC CA,SC CA,CT,SC CA,CT CA,CT,SC -31S CA,MR CA CA,MR CA - CA,MR CA,MR MR40S CA,CT,MR,XH,XN CA,CT,MR,RN,RH CA,CT,MR,RN,RH CA,CT,MR CA CA,MR CA,CT,MR,XH,XN MR40M CA,CT,SC CA,CT,SC CA,CT,SC CA,SC CA,CT,SC CA CA,CT CT23/24S CA,CT, CA,CT, CA,CT CA,CT - CA CA,CT -23/24M CA CA CA CA - CA CA -
Watts MT1 MT2 MT7 TT3 5T417M CA CA CA CA -20S CT,CA CT,CA CT,CA - -25S CA,CT,MR CA,CT,MR CA,CT CA,CT CA25M CA,SC CA,SC CA,SC CA,CT,SC CA31S CA CA CA - -40S CA,CT,MR CA,CT,MR CA,CT CA CA40M CA,SC CA,SC CA,SC CA,CT,SC CA23/24S CA,CT CA,CT CA,CT - -23/24M CA CA CA - -
B A L L A S T M A T R I C E S
56 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Interstate II 775
Interstate II 775 continued
Multi-Mount 285
Multi-Mount 285 continued
Roadway Lighting
Watts 120 208 240 277 480 DT2 DT420S CA,CT,MR,XN,XH CA, CT CA,CT,MR,RN,RH CA,CT CA,CT,MR CA,CT,MR,XN,XH -25S CA,CT,MR,XN,XH CA,CT,MR CA,CT,MR,RN,RH CA,CT,MR CA,MR XN,XH,MR MR25M CA,CT,SC CA,SC CA,CT,SC CA,SC CA,CT CA,CT,SC -31S CA,MR CA CA,MR CA CA,MR CA,MR MR40S CA,CT,MR,XN,XH CA,CT,MR,RN,RH CA,CT,MR,RN,RH CA,CT,MR CA,MR CA,CT,MR,XN,XH MR40M CA,CT,SC CA,CT,SC CA,CT,SC CA,SC CA CA,CT CT23/24S CA,CT, CA,CT, CA,CT CA,CT CA CA,CT -23/24M CA CA CA CA CA CA -
Watts MT1 MT2 MT7 TT3 347 5T120S CT,CA CT,CA CT,CA - - -25S CA,CT,MR CA,CT,MR CA,CT CA,CT CA CA25M CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC CA31S CA CA CA - - -40S CA,CT,MR CA,CT,MR CA,CT CA CA CA40M CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC CA23/24S CA,CT CA,CT CA,CT - - -23/24M CA CA CA - - -
Watts 120 208 240 277 480 DT2 DT417M CA CA CA CA CA CA -20S CA,CT,MR,XN,XH CA, CT CA,CT,MR,RN,RH CA,CT CA,CT,MR CA,CT,MR,XN,XH -25S CA,CT,MR,XN,XH CA,CT,MR CA,CT,MR,RN,RH CA,CT,MR CA,MR XN,XH,MR MR25M CA,CT,SC CA,SC CA,CT,SC CA,SC CA,CT CA,CT,SC -31S CA,MR CA CA,MR CA CA,MR CA,MR MR40S CA,CT,MR,XN,XH CA,CT,MR,RN,RH CA,CT,MR,RN,RH CA,CT,MR CA,MR CA,CT,MR,XN,XH MR40M CA,CT,SC CA,CT,SC CA,CT,SC CA,SC CA CA,CT CT23/24S CA,CT, CA,CT, CA,CT CA,CT CA CA,CT -23/24M CA CA CA CA CA CA -
Watts MT1 MT2 MT7 TT3 347 5T117M CA CA CA CA CA -20S CT,CA CT,CA CT,CA - - -25S CA,CT,MR CA,CT,MR CA,CT CA,CT CA CA25M CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC CA31S CA CA CA - - -40S CA,CT,MR CA,CT,MR CA,CT CA CA CA40M CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC CA23/24S CA,CT CA,CT CA,CT - - -23/24M CA CA CA - - -
57Product Guide
B A L L A S T M A T R I C E S
LPS Roadway SP2Watts 120 208 240 277 347 480 DT1 DT2 DT5 DT609L XH XH XH XH XH XH XH XH XH XH13L XH XH XH XH XH RH,XH XH XH XH XH18L XH XH XH XH XH XH XH XH XH XH
LPS Roadway SRXWatts 120 208 240 277 347 480 DT1 DT2 DT5 DT603L XH XH XH XH XH RH XH XH XH XH55L XH XH XH XH XH RH XH XH XH XH09L XH XH XH XH XH RH XH XH XH XH
UnderPass Series 581/681Watts 120 208 240 277 480 DT205S RN - - - - -07S CA,CT,MR,RN RH CA,CT,XN,XH CA,CT,MR,XN,XH CA,XN,XH CA CA,CT,MR,XN,XH10S CA,CT,RN,RH CA,CT,XN,XH CA,CT,XN,XH CA,CT,XN,XH CA CA,CT15S CA,MR,RN,RH CA,XN,XH CA,MR,XN,XH CA,XN,XH CA,MR CA,MR17M CA CA CA CA CA CA20S XN,XH - XN,XH - - XN,XH25S XN,XH - XN,XH - - XN,XH25M CA CA CA CA - CA
UnderPass Series 581/681 continuedWatts DT4 MT1 MT2 MT7 MT8 TT1 TT3 TT7 34705S - - - - - - - - -07S MR CA CA CA CA XN,XH XN,XH XN,XH XN,XH10S - CA,CT CA,CT CA,CT CA,CT XN,XH XN,XH XN,XH CT,XN,XH15S MR CA CA CA CA XN,XH XN,XH XN,XH XN,XH17M - CA CA CA CA CA CA CA CA20S - - - - - - - - -25S - - - - - - - - -25M - CA CA CA CA - - - -
Roadway Lighting
B A L L A S T M A T R I C E S
58 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
SignLite 875
SignLite 875 continued
Heavy Duty Wallpack 882
Heavy Duty Wallpack 882 continued
Roadway Lighting
Watts 120 208 240 277 480 DT2 DT417M CA CA CA CA CA CA -20S CA, CT, XN, XH MR CA, CT CA,CT,RN,RH,MR CA,CT CA,CT,MR CA,CT,MR,XN,XH -25S XH,XN,CA,CT,MR CA,CT,MR CA,CT,RN,RH,MR CA,CT,MR CA,MR XN,XH,MR MR25M CA,CT,SC CA,SC CA,CT,SC CA,SC CA,CT CA,CT,SC -31S CA,MR CA CA,MR CA CA,MR CA,MR MR40S CA,CT,XN,XH,MR CA,CT,MR,RN,RH CA,CT,RN,RH,MR CA,CT,MR CA,MR CA,CT,MR,XN,XH MR40M CA,CT,SC CA,CT,SC CA,CT,SC CA,SC CA CA,CT CT23/24S CA,CT, CA,CT, CA,CT CA,CT CA CA,CT -23/24M CA CA CA CA CA CA -
Watts MT1 MT2 MT7 TT3 347 5T417M CA CA CA CA CA -20S CT,CA CT,CA CT,CA - - -25S CA,CT,MR CA,CT,MR CA,CT CA,CT CA CA25M CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC CA31S CA CA CA - - -40S CA,CT,MR CA,CT,MR CA,CT CA CA CA40M CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC CA23/24S CA,CT CA,CT CA,CT - - -23/24M CA CA CA - - -
Watts 120 208 240 277 480 DT2 DT417M CA CA CA CA CA CA -20S CA,CT,MR,XN,XH CA, CT CA,CT,MR,RN,RH CA,CT CA,CT,MR CA,CT,MR,XN,XH -25S CA,CT,MR,XN,XH CA,CT,MR CA,CT,MR,RN,RH CA,CT,MR CA,MR MR,XN,XH MR25M CA,CT,SC CA,SC CA,CT,SC CA,SC CA,CT CA,CT,SC -31S CA,MR CA CA,MR CA CA,MR CA,MR MR40S CA,CT,MR,XN,XH CA,CT,MR,RN,RH CA,CT,MR,RN,RH CA,CT,MR CA,MR CA,CT,MR,XN,XH MR40M CA,CT,SC CA,CT,SC CA,CT,SC CA,SC CA CA,CT CT
Watts MT1 MT2 MT7 TT3 347 5T417M CA CA CA CA CA -20S CT,CA CT,CA CT,CA - - -25S CA,CT,MR CA,CT,MR CA,CT CA,CT CA,CT CA25M CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC CA31S CA CA CA - - -40S CA,CT,MR CA,CT,MR CA,CT CA CA CA40M CA,SC CA,SC CA,SC CA,CT,SC CA,CT,SC CA
DECORATIVE AND POST TOP LIGHTING
Decorative Poles ......................................................90
Chadsworth Series................................................90
New Albany Series ...............................................92
Statesboro Series..................................................94
Waycross Series ...................................................96
Weatherproof Receptacles .................................98
Ballast Matrices .....................................................100
Valiant ........................................................................60
American Revolution Deluxe Series ....................62
American Revolution Series 247............................64
Georgian Series GRP ...............................................66
Bainbridge Series 870 .............................................68
Marietta Series.........................................................70
Sumter Series ...........................................................72
Cresthill Classic ........................................................74
Cresthill Sphere ........................................................76
Cresthill Centennial..................................................78
Cresthill Glass ...........................................................80
Lexington ...................................................................82
Branson......................................................................84
Contempo Series 245 ..............................................86
TwistPack Series TWT ............................................88
American Electric Lighting®
59
P R O D U C T O V E R V I E W
60 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
ValiantTM
Series AVP50-250W HPS, 70-250W MH
Features:Die-cast aluminum housing and hood for long-life performance
Optical assembly designed for maximum performance
Hinged hood and captive screw provision afford quick, easy access toelectrical and optical area for relamping or servicing. Trigger latch (TL) optional
Slipfitter with three set screws allows secure installation to pole sizes 2-3/8"or 3" O.D.
E39 mogul base socket standard
Tool-less cupola for easy photocontrol adjustment
Tooled cupola lens to prevent wildlife entry into luminaire
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.3.1
Suitable for -30°C MH / -40°C HPS
40°C Rated
Encapsulated plug-in starter, standard
Stainless steel fasteners (external), standard
Terminal block, standard
Applications:StreetscapesWalkwaysPathwaysParks
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Valiant 2.4 sq. ft.The EPA for the Valiant Vieux is 2.4 sq. ft.The EPA for the Valiant Full Cutoff is 1.5 sq. ft.Approx. Wt. = 36 lbs.
VIEUX OPTIONFULL CUTOFF
PREFERRED SELECTION CATALOG NUMBERS
AVP 13S RH 120 R3 FC NL TLAVP 10S CA MT1 R3 AY LC PC LDR PA30AVP 10S CA MT1 R5 AY VX LC PC LDR PA30AVP 10S RN 120 R3 AY TLAVP 10S RN 120 R5 AY TLAVP 13S RH 120 R3 AY NL HS TL
NEW
61Product Guide
O R D E R I N G I N F O R M A T I O N
ValiantTM
Series AVP50-250W HPS, 70-250W MH
Post Top DesignVX Valiant Vieux4
Paint(blank) Black Textured (standard)
GY GrayWH White
FusingSF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480)
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR PECR with Shorting Cap Installed
LampLC Lamp Included, Clear
Options
ListingUL UL ListedCS CSA Certified
Misc.PC Photocontrol Included per
Voltage Specified5
NL NEMA Label AttachedHS Houseside Shield4
SH Shorting Cap5
TL Tool-less Trigger Latch EntryHP High Performance Optics6
LDR Ladder Rest7
PA30 Terminal Block Pre-wired 30’# 10 CU Solid B/W/G
PB30 Terminal Block Pre-wired 30’# 10 CU Solid B/B/G
PC30 Terminal Block Pre-wired 30’# 10 CU Solid B/B/W/G
Example: A V P 1 7 M C A M T 1 R 3 A Y L C P C L D R P A 3 0
AVP Valiant Post Top 05 50W07 70W10 100W13 100/150W15 150W17 175W20 200W1
25 250W
DistributionBallastWattage / SourceSeries
R2 Type IIR3 Type IIIR5 Type V
Refer to optical matrixbelow for compatibility
CA CWA Autotransformer
CT CWIAutotransformer
SC SCWA2
RH Reactor High Power Factor
RN Reactor Normal Power Factor
XH High Reactance/LagHigh Power Factor
XN High Reactance/LagNormal Power Factor
Refer to ballast matrix onpage 100 for compatibility.
S HPSM MH
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
DT1 Dual Tap 120/240wired 120
DT2 Dual Tap 120/240wired 240
MT1 Multi-tap Wired 120MT2 Multi-tap Wired 240MT7 Multi-tap Wired 277MT8 Multi-tap Wired 208TT3 Tri-tap Wired 347
Optics
AY AcrylicPY Polycarbonate3
FC Full Cutoff8
Notes:
1 Available in HPS only2 Contact factory for availability3 PY available in 175W max4 Full cutoff not available5 Not available with NR option6 Not available with VX or FC options7 Ships with unit, field installed8 Nighttime FriendlyTM optic
R2 AY R3 AY R5 AY R3 AY VX R5 AY VX R3 FC R2 AY HP R5 AY HP05S � � � � � � � �
07S � � � � � � � �
10S � � � � � � � �
15S � � � � � � � �
20S � � � � � - � �
25S � � � � � - � �
17M � � � � � � � �
25M � � � � � � � �
Optic Distribution
P R O D U C T O V E R V I E W
62 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
American Revolution DeluxeSeries ARD and ARD Cutoff50-150W HPS, 70-175W MH
Features:Die-cast aluminum housing and hood for long-life performance
Die-cast trigger latch (TL) option available for easy access to internalcomponents
Optical assembly designed for maximum performance
Hinged hood and captive screw provision afford quick, easy access toelectrical and optical area for relamping or servicing
Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or3" O.D.
E39 Mogul base socket standard
Meets IESNA Full Cutoff classification
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30ºC MH / -40ºC HPS
Tool-less cupola for easy photocontrol adjustment
Tooled cupola lens to prevent wildlife entry into luminaire
Complies with ANSI: C136.2, C136.10, C136.15, C136.3.1
40°C Rated
Stainless steel fasteners (external), standard
Terminal block, standard
Full cutoff version is “Nighttime FriendlyTM”
Applications:StreetscapesWalkwaysPathwaysParks
DIMENSIONS
Effective Projected Area (EPA)The EPA for the American Revolution Series 247 is 1.6 sq. ft.Approx. Wt. = 36 lbs.
PREFERRED SELECTION CATALOG NUMBERS
ARD 10S RN 120 R3 AY EC TLARD 10S RN 120 R5 AY EC TLARD 10M XN MT1 R3 AY TLARD 10S CA MT1 R2 FC EC TL
NEW
63Product Guide
O R D E R I N G I N F O R M A T I O N
Example: A R D 1 5 S R N 1 2 0 R 5 A Y E C
American Revolution DeluxeSeries ARD and ARD Cutoff
50-150W HPS, 70-175W MH
ARD American RevolutionDeluxePost Top
05 50W07 70W10 100W15 150W17 175W
DistributionBallastWattage / SourceSeries
R2 Type IIR3 Type III11
R5 Type V2,11
RV Type V3.11
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance / Lag Normal Power Factor
XH High Reactance / Lag High Power Factor
CA CWA Autotransformer
Refer to ballast matrix onpage 100 for compatibility.
S HPSM MH
Notes:
1 Voids UL/CSA Listing2 Four white panels3 Four clear panels4 Other colors available, please contact your local
American Electric Lighting representative5 PC, SH not available with NR option6 HPS only7 Limited availability, please contact your local
American Electric Lighting representative8 T3 option only available with 240, 480, DT2, DT4, MT29 Acrylic only
10 Not available in MT voltage11 Not available on FC version12 Nighttime FriendlyTM optic13 Ships with unit, field installed
Voltage
120 120V208 208V240 240V277 277V480 480V
MT1 Multi-tap wired 120VMT8 Multi-tap wired 208VMT2 Multi-tap wired 240VMT7 Multi-tap wired 277V
AY Acrylic*PY Polycarbonate*FC Full Cutoff12
Optics
Paint4
(blank) Black (standard)GY Gray
WH WhiteBZ Bronze
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionT3 3 Wire Operation (L1, N, L2 Position)11
Listing11
UL UL ListedCS CSA Certified
Fusing10
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle5
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter6
(blank) Open Board (standard)EC Encapsulated Plug-in11
OP Open Plug-in11
Misc.PC Photocontrol Included per
Voltage Specified5
SH Shorting Cap5
SS Stainless Steel Hardware5H 50 Hertz Ballast Cycle7
NL NEMA Label (2x2)HS House Side Shield9
TL Tool-less EntryLDR Ladder Rest13
*Refer to optical matrix below for compatibility
R2 AY R3 AY R5 AY RV AY R2 PY R3 PY R5 PY RV PY R2 FC05S � � � � � � � � �
07S � � � � � � � � �
10S � � � � � � � � �
15S � � � � � � � � �
07M � � � � � � � � �
10M � � � � � � � � �
15M � � � � � � � � �
17M � � � � � � � � �
Optic Distribution
P R O D U C T O V E R V I E W
64 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
American RevolutionSeries 247 and 247 Cutoff50-150W HPS, 70-175W MH
Features:Die-cast aluminum housing and hood for long-life performance
Die-cast trigger latch (TL) option available for easy access to internalcomponents
Optical assembly designed for maximum performance
Hinged hood and captive screw provision afford quick, easy access toelectrical and optical area for relamping or servicing
Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or3" O.D.
E39 mogul base socket standard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31 (regular only), C136.16(FC only)
Suitable for -30°C MH & / -40°C HPS
Full cutoff version is “Nighttime FriendlyTM”
Applications:StreetscapesWalkwaysPathwaysParks
DIMENSIONS
Effective Projected Area (EPA)The EPA for the American Revolution Series 247 is 1.6 sq. ft.Approx. Wt. = 36 lbs.
PREFERRED SELECTION CATALOG NUMBERS
Series 247247 10S RN 120 R3 AY247 15S RN 120 R3 AY247 10S RN 120 R5 AY247 15S RN 120 R5 AY
Series 247 Cutoff247 10S RN 120 R2 FC TL247 10M XN MT1 R2 FC TL
SERIES 247
SERIES 247 CUTOFF
65Product Guide
O R D E R I N G I N F O R M A T I O N
Example: 2 4 7 1 5 S R N 1 2 0 R 5 A Y E C
American RevolutionSeries 247 and 247 Cutoff
50-150W HPS, 70-175W MH
247 American RevolutionPost Top
05 50W07 70W10 100W15 150W17 175W
DistributionBallastWattage / SourceSeries
R2 Type IIR3 Type III11
R5 Type V2,11
RV Type V3.11
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance / Lag Normal Power Factor
XH High Reactance / Lag High Power Factor
CA CWA AutotransformerCT CWI Autotransformer
Refer to ballast matrix onpage 101 for compatibility.
S HPSM MH
Notes:
1 Voids UL/CSA Listing2 Four white panels3 Four clear panels4 Other colors available, please contact your local
American Electric Lighting representative5 PC, SH not available with NR option6 HPS only7 Limited availability, please contact your local
American Electric Lighting representative8 T3 option only available with 240, 480, DT2, DT4, MT29 Acrylic only
10 Not available in MT, TT, DT voltages11 Not available on FC version12 Nighttime FriendlyTM optic13 Ships with unit, field installed
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240V
AY Acrylic*PY Polycarbonate*FC Full Cutoff12
Optics
Paint4
(blank) Black (standard)GY Gray
WH WhiteBZ Bronze
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionT3 3 Wire Operation (L1, N, L2 Position)11
Listing11
UL UL ListedCS CSA Certified
Fusing10
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle5
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter6
(blank) Open Board (standard)EC Encapsulated Plug-in11
OP Open Plug-in11
Misc.PC Photocontrol Included per
Voltage Specified5
SH Shorting Cap5
SS Stainless Steel Hardware5H 50 Hertz Ballast Cycle7
NL NEMA Label (2x2)HS House Side Shield9
TL Tool-less EntryLDR Ladder Rest13
*Refer to optical matrix below for compatibility
R2 AY R3 AY R5 AY RV AY R2 PY R3 PY R5 PY RV PY R2 FC05S � � � � � � � � �
07S � � � � � � � � �
10S � � � � � � � � �
15S � � � � � � � � �
07M � � � � � � � � �
10M � � � � � � � � �
15M � � � � � � � � �
17M � � � � � � � � �
Optic Distribution
P R O D U C T O V E R V I E W
66 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
GeorgianSeries GRP50-150W HPS, 70-175W MH
Applications:Residential areasArchitectural landscape lightingParks, walkwaysRecreational areasCommercial environments
Features:Two (2) piece cast aluminum housing
Castings are hinged and open with a simple 1/4 turn thumb screw for easymaintenance
Choice of two (2) mounting arrangements: side entry or post top
Lenses are sealed with neoprene gaskets to prevent ingress of dirt ormoisture in luminaire. Bottom lens is sealed with a felt gasket for properbreathing of luminaire (top entry and side entry units only)
All ballasts are mounted on a ballast plate with quick disconnect, for easyreplacement
All exposed screws are stainless steel
Cast aluminum slipfitter accepts 3” to 3-1/2” O.D. X 4” long tenon or pole.Mounting hardware included
A photocell cupola is supplied when ordering the photocell receptacle
Mogul base socket
Certified by CSA and UL standards
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.16
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Georgian is 2.93 sq. ft.Approx. Wt. = 46 lbs.
PREFERRED SELECTION CATALOG NUMBERS
GRS 10S CT DT1 R2 RD SB CS EC NL PC PYGRS 15S CT DT1 R3 RD CS EC NL PC PYGRP 10S CT DT1 R3 RD SB CS EC NL PC CD PYGRP 15S CT DT1 R3 RD SB CS EC PC NL PY
SIDE MOUNTPOST TOP
67Product Guide
O R D E R I N G I N F O R M A T I O N
GeorgianSeries GRP
50-150W HPS, 70-175W MH
GRP Post TopGRS Side MountGRL Post Top w/
ladder rest
05 50W07 70W10 100W15 150W17 175W
DistributionBallastWattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type IIIR5 Type 51
CA CWA AutotransformerCT CWI AutotransformerRN Reactor Normal
Power FactorRH Reactor High
Power FactorXN High Reactance / Lag
Normal Power FactorXH High Reactance / Lag
High Power Factor
Refer to ballast matrix onpage 102 for compatibility.
M MHS HPS
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
DT1 Dual Tap 120/240 Wired 120DT2 Dual Tap 120/240 Wired 240MT1 Multi-tap Wired 120MT2 Multi-tap Wired 240MT7 Multi-tap Wired 277TT3 Tri-tap Wired 347
RD High PerformanceRoadway Reflector
OA Open Bottom Acrylic2
CR Cone Reflector
Optics
Options
Paint(blank) Black (standard)
BZ BronzeGY Gray
WH WhiteSB Shibui Brown
Terminal BlockT2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2 Position)3
Listing(blank) UL Listing (standard)
CS CSA Certified
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter4
EC Encapsulated Plug-inOP Open Plug-in
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
NR No Receptacle
Misc.PC Photocontrol IncludedSH Shorting Cap NL NEMA LabelCH Decorative Chimney2
CD Decorative Candle2
CB Century Base
Side PanelsGL GlassPY PolycarbonateAY AcrylicPE Pebbled Glass
Example: G R P 1 0 S R H 1 2 0 R 3 R D P Y
Notes:
1 Available only with OA optics2 Cannot be used together with other optics3 T3 option only available with 240, 480, DT2, DT4, MT24 HPS only
P R O D U C T O V E R V I E W
68 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
BainbridgeSeries 87050-150W HPS,175W MH
Features:Architecturally complimentary design
Powdercoated, paint finish
Terminal block for ease of wiring
A variety of wattages and ballast types
Available in HPS and MH
Easy access to electrical components
Available in a variety of IES distributions
E39 mogul base socket standard
All electrical components warranted by American Electric Lighting’s 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Applications:Office buildingsShopping centersMallsApartment/condominium complexesCommercial developments
16-1/2”(419)
27”(686)
37”(940)
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Bainbridge Series 870 is 3.7 sq. ft.Approx. Wt. = 28 lbs.
69Product Guide
O R D E R I N G I N F O R M A T I O N
BainbridgeSeries 870
50-150W HPS,175W MH
Series
870 Bainbridge
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W
S HPSM MH
CA CWA AutotransformerRH Reactor High
Power FactorRN Reactor Normal
Power FactorXH High Reactance / Lag
High Power FactorXN High Reactance / Lag
Normal Power Factor
Refer to ballast matrix on page 102for compatibility.
120 120V208 208V240 240V277 277V480 480V
DT2 Dual Tap 120/240Wired 240
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277V
Distribution
R3 Type III1
R5 Type V1
R0 No Internal Refractor
Options
AY AcrylicPY Polycarbonate
WC White Polycarbonate
Optics
Paint(blank) Black (standard)
BZ Bronze
Terminal BlockT2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2 Position)2
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Photocontrol(blank) None
BC Button-photocontrol
Misc.SS Stainless Steel HardwareNL NEMA Label
Example: 8 7 0 1 0 S C A M T 1 R 3 A Y L C
Notes:
1 Achieved with internal glass refractor2 T3 option only available with 240, 480, DT2, DT4, MT2
P R O D U C T O V E R V I E W
70 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
P R O D U C T O V E R V I E W
Applications:StreetscapesWalkwaysPathwaysParks
MariettaSeries LMD50-250W HPS, 50-250W MH
Effective Projected Area (EPA)The EPA for the Marietta Series is 2.7 sq. ft.Approx. Wt. = 24lbs.
DIMENSIONS
Features:Available in solid or clear top prismatic globe
Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Available in Semi-Cutoff IES classification
Injection-molded, high-impact acrylic or polycarbonate
Excellent uniformity, light distribution and efficiency
Maximizes pole spacing
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket forquick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access fromcomponent door
Uplight shield is standard
E39 mogul base socket standard
Mounts to 3” x 3” pole top tenons
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
PREFERRED SELECTION CATALOG NUMBERS
LMD 10S RN 120 R3 PA PRLMD 10S RN 120 R5 PA PRLMD 10M XN MT1 R3 PA PRLMD 10M XN MT1 R5 PA PR
71Product Guide
O R D E R I N G I N F O R M A T I O N
Example: L M D 1 7 M C A M T 1 R 5 P A P R P C
Series
LMD Marietta
Notes:
1 For use with PR option2 250W adds 3” to housing height3 Other colors available, please contact your local
American Electric Lighting representative4 T3 option only available with 240, 480, DT2, DT4, MT25 Standard with PA optic
GlobePA Prismatic Acrylic SolidTop (optical)PT Prismatic Clear Top Polycarbonate
(optical)PN Prismatic Clear Top Acrylic
(optical)
Paint3
(blank) BlackVG Verde GreenBZ Bronze
Terminal Block(blank) Terminal Block (std)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operations (L1, N, L2 Position)4
Receptacle(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
MiscPC Locking Type Photocontrol1SH Shorting Cap1
SS Stainless Steel Fasteners (external)BD Without Decorative CageF5 Spike Finial5TL Tool-less Entry
US Uplight Shield
MariettaSeries LMD
50-250W HPS, 50-250W MH
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W25 250W2
S HPSM MH
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance/Lag NPFXH High Reactance/Lag HPFCA CWA Auto-RegCT CWI
Refer to ballast matrix on page 102for compatibility.
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VDT2 Dual Tap 120/240
Wired 240VTT3 Tri-tap Wired 347V
Distribution
R3 Type IIIR5 Type V
Options
P R O D U C T O V E R V I E W
72 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
P R O D U C T O V E R V I E W
Features:Solid top prismatic globe
Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Available in Semi-Cutoff IES classification
Injection-molded, high-impact acrylic or polycarbonate
Excellent uniformity, light distribution and efficiency
Maximizes pole spacing
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket forquick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access fromcomponent door
E39 mogul base socket standard
Mounts to 3” x 3” pole top tenons
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Applications:StreetscapesWalkwaysPathwaysParks
SumterSeries LSH50-250W HPS, 50-250W MH
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Sumter Series is 2.7 sq. ft.Approx. Wt. = 24 lbs.
73Product Guide
O R D E R I N G I N F O R M A T I O N
Example: L S H 1 7 M C A 1 2 0 R 5 P A P R L C P C
Series
LSH Sumter
Notes:
1 250W adds 3” to housing height2 T3 option only available with 240, 480, DT2, DT4, MT23 For use with PR option
GlobePP Prismatic Polycarbonate (optical)PA Prismatic Acrylic (optical)
Paint(blank) Black
VG Verde GreenBZ Bronze
Terminal Block(blank) Terminal Block (std)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operations (L1, N, L2 Position)2
Receptacle(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
MiscPC Locking Type Photocontrol3SH Shorting Cap3
SS Stainless Steel Fasteners (external)
SumterSeries LSH
50-250W HPS, 50-250W MH
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W25 250W1
S HPSM MH
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance/Lag NPFXH High Reactance/Lag HPFCA CWA Auto-RegCT CWI
Refer to ballast matrix on page 103for compatibility.
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VDT2 Dual Tap 120/240
Wired 240TT3 Tri-tap Wired 347V
Distribution
R3 Type IIIR5 Type V
Options
P R O D U C T O V E R V I E W
74 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Cresthill ClassicSeries LCR50-150W HPS, 50-175W MH
Features:Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Globe available in stepped acrylic and polycarbonate or prismatic acrylic andpolycarbonate
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket forquick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access fromcomponent door
E39 mogul base socket standard
Mounts to 3” x 3” pole top tenons
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Applications:StreetscapesWalkwaysPathwaysParks
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Cresthill Classic is 1.4 sq. ft.Approx. Wt. = 37 lbs.
PREFERRED SELECTION CATALOG NUMBERS
LCR 10S RN 120 R5 AA PR
75Product Guide
O R D E R I N G I N F O R M A T I O N
Example: L C R 1 0 S R N 1 2 0 R 5 A P P R L C P R
Series
LCR Cresthill
Notes:
1 Not available with PN or PT options2 Achieved with internal glass refractor
except with prismatic globes3 T3 option only available with 240, 480, DT2, DT4, MT24 For use with PR options5 For use with PN and PT only
Globe AP Classic Large Clear Polycarbonate
(Non-optical)AA Classic Large Clear Acrylic
(Non-optical)PT Prismatic Polycarbonate (optical)PN Prismatic Acrylic (optical)
Paint(blank) Black
VG Verde GreenBZ Bronze
Terminal Block(blank) Terminal Block (std)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operations (L1, N, L2 Position)3
Receptacle(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
MiscF5 Finial
PC Locking Type Photocontrol4SH Shorting Cap4
SS Stainless Steel Fasteners (external)US Uplight Shield5
9R 9" Globe Neck
Cresthill ClassicSeries LCR
50-150W HPS, 50-175W MH
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W
S HPSM MH
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance/Lag NPFXH High Reactance/Lag HPFCA CWA Auto-RegCT CWI
Refer to ballast matrix on page 103for compatibility.
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VDT2 Dual Tap 120/240
Wired 240
Distribution
R0 No InternalRefractor1
R3 Type III2
R5 Type V2
Options
P R O D U C T O V E R V I E W
76 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Cresthill SphereSeries LCR50-150W HPS, 50-175W MH
Applications:StreetscapesWalkwaysPathwaysParks
DIMENSIONS
Features:Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Globe 22” white acrylic or clear polycarbonate
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socketfor quick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy accessfrom component door
E39 mogul base socket standard
Mounts to 3” x 3” pole top tenons
Powdercoat finish
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Effective Projected Area (EPA)The EPA for the Cresthill Sphere is 2.5 sq. ft.Approx. Wt. = 22lbs.
77Product Guide
O R D E R I N G I N F O R M A T I O N
Series
LCR Cresthill
Notes:
1 Achieved with internal glass refractor 2 Available in 9R only, requires 9R housing3 T3 option only available with 240, 480, DT2, DT4, MT24 For use with PR options5 For 9” neck 22” diameter globe is used
GlobeSL Sphere White Polycarbonate2
SY Sphere White Acrylic2
Paint(blank) Black
VG Verde GreenBZ Bronze
Terminal Block(blank) Terminal Block (std)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operations (L1, N, L2 Position)3
Receptacle(blank) No Photocontrol Receptacle (standard)
PR Photocontrol Receptacle
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Photocontrol(blank) None
PC Locking Type Photocontrol4
MiscSH Shorting Cap4
SS Stainless Steel Fasteners (external)9R 9" Globe Neck5
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W
S HPSM MH
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance/Lag NPFXH High Reactance/Lag HPFCA CWA Auto-RegCT CWI
Refer to ballast matrix on page 103for compatibility.
120 120V208 208V240 240V277 277V480 480V
MT1 Multi-tap Wired 120VMT8 Multi-tap Wired 208VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VDT1 Dual Tap 120/240
Wired 120DT2 Dual Tap 120/240
Wired 240
Distribution
R0 No Internal Refractor
R3 Type III1
R5 Type V1
Example: L C R 1 0 S R N 1 2 0 R 5 S Y P R L C P C
Cresthill SphereSeries LCR
50-150W HPS, 50-175W MH
Options
P R O D U C T O V E R V I E W
78 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Applications:StreetscapesWalkwaysPathwaysParks
DIMENSIONS
Features:Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Acrylic or polycarbonate globe
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socketfor quick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy accessfrom component door
E39 mogul base socket standard
Mounts to 3” x 3” pole top tenons
Powdercoat finish
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Cresthill CentennialSeries LCR50-150W HPS, 100-175W MH
Effective Projected Area (EPA)The EPA for the Cresthill Centennial is 1.2 sq. ft.Approx. Wt. = 22lbs.
79Product Guide
O R D E R I N G I N F O R M A T I O N
Example: L C R 1 0 S R N 1 2 0 R 5 C Y P R L C P C
Series
LCR Cresthill
Notes:
1 Achieved with internal glass refractor 2 For use with 9R option only, requires 9R housing3 T3 option only available with 240, 480, DT2, DT4, MT24 For use with PR options
GlobeCE Centennial Large Clear Acrylic
(Non-optical)CW Centennial Large White
Polycarbonate2
CY Centennial Large Clear AcrylicCM Centennial Medium Clear Acrylic
Paint(blank) Black
VG Verde GreenBZ Bronze
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operations (L1, N, L2 Position3
Receptacle(blank) No Photocontrol Receptacle
(standard)PR Photocontrol Rseceptacle
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
MiscPC Twist-off Photocontrol4SH Shorting Cap4
SS Stainless Steel Fasteners (external)9R 9" Globe Neck
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W
S HPSM MH
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance/Lag NPFXH High Reactance/Lag HPFCA CWA Auto-RegCT CWI
Refer to ballast matrix on page 103for compatibility.
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347DT2 Dual Tap 120/240
Wired 240
Distribution
RO No Internal Refractor
R3 Type III1
R5 Type V1
Cresthill CentennialSeries LCR
50-150W HPS, 100-175W MH
Options
P R O D U C T O V E R V I E W
80 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Cresthill GlassSeries LCR50-250W HPS, 50-250W MH
Applications:StreetscapesWalkwaysPathwaysParks
DIMENSIONS
Features:Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Prismatic glass globe
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket forquick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access fromcomponent door
E39 mogul base socket standard
Mounts to 3” x 3” pole top tenons
Powdercoat finish
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Effective Projected Area (EPA)The EPA for the Cresthill Glass is 1.4 sq. ft.Approx. Wt. = 37lbs.
81Product Guide
O R D E R I N G I N F O R M A T I O N
Example: L C R 1 0 S R N 1 2 0 R 5 P G P R L C P C
Series
LCR Cresthill
Notes:
1 250 W adds 3” to cast housing height2 T3 option only available with 240, 480, DT2, DT4, MT23 For use with PR options
Options
GlobePG Prismatic Glass
Paint(blank) Black
VG Verde GreenBZ Bronze
Terminal Block(blank) Terminal Block (std)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operations (L1, N, L2 Position)2
Receptacle(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
MiscPC Locking Type Photocontrol3SH Shorting Cap3
SS Stainless Steel Fasteners (external)F5 Finial
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W25 250W1
S HPSM MH
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance/Lag NPFXH High Reactance/Lag HPFCA CWA Auto-RegCT CWI
Refer to ballast matrix on page 104for compatibility.
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347DT2 Dual Tap 120/240
Wired 240
Distribution
R3 Type IIIR5 Type V
Cresthill GlassSeries LCR
50-250W HPS, 50-250W MH
P R O D U C T O V E R V I E W
82 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Applications:StreetscapesWalkwaysPathwaysParks
LexingtonSeries LLX50-150W HPS, 100-175W MH
Features:Available with or without spikes
Interchangeable base with a wide variety of lenses
Symmetric or Asymmetric distribution
Decorative spike finial standard
Rugged cast-aluminum housing
Lens available in acrylic, polycarbonate or clear glass
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket forquick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access fromcomponent door
E39 mogul base socket standard
Mounts to 3” x 3” pole top tenons
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPSDIMENSIONS
Effective Projected Area (EPA)The EPA for the Lexington is 3.1 sq. ft.Approx. Wt. = 33 lbs.
83Product Guide
O R D E R I N G I N F O R M A T I O N
Example: L L X 1 0 S R N 1 2 0 R 5 A Y P R L C P C
LexingtonSeries LLX
50-150W HPS, 100-175W MH
Series
LLX Lexington
Notes:
1 Achieved with internal glass refractor2 T3 option only available with 240, 480, DT2, DT4, MT23 For use with PR option
Options
GlobeAY AcrylicPY PolycarbonateGL Glass
Paint(blank) Black
VG Verde GreenBZ Bronze
Terminal Block(blank) Terminal Block (std)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operations (L1, N, L2 Position)2
Receptacle(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
MiscPC Locking Type Photocontrol3SH Shorting Cap3
SS Stainless Steel Fasteners (external)NS No Spikes on LLX Housing
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W
S HPSM MH
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance/Lag NPFXH High Reactance/Lag HPFCA CWA Auto-RegCT CWI
Refer to ballast matrix on page 104for compatibility.
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VDT2 Dual Tap 120/240
Wired 240
Distribution
R0 No Internal Refractor
R3 Type III1
R5 Type V1
P R O D U C T O V E R V I E W
84 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Ornamental aluminum canopy top
Interchangeable base with a variety of globes
Symmetric or Asymmetric distribution
Base and optical ship separately
Powdercoat finish
HPS units standard with encapsulated starter that is located at the socket forquick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access fromcomponent door
E39 mogul base lamp holder standard
Mounts to 3” x 3” pole top tenons
Available in stippled acrylic or polycarbonate globes
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30°C MH / -40°C HPS
Applications:StreetscapesWalkwaysPathwaysParks
BransonSeries LBR50-150W HPS, 50-175W MH
13”(330)
38”(965)
3-1/4”(83)
DIMENSIONS
Effective Projected Area (EPA)The EPA for the Branson is 2.3 sq. ft.Approx. Wt. = 22 lbs.
PREFERRED SELECTION CATALOG NUMBERS
LBR 10S RN 120 R3 AY PRLBR 10S RN 120 R5 AY PR
85Product Guide
O R D E R I N G I N F O R M A T I O N
Example: L B R 1 5 S C A M T 1 R 5 P Y L C
Series
LBR Branson
Notes:
1 Achieved with internal glass refractor except with prismatic globes
2 Other colors available, please contact your localAmerican Electric Lighting representative
3 T3 option only available with 240, 480, DT2, DT4, MT24 For use with PR option
GlobeAY AcrylicPY Polycarbonate
Paint2
(blank) Black
Terminal Block(blank) Terminal Block (std)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operations (L1, N, L2 Position)3
Receptacle(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
MiscPC Locking Type Photocontrol4SH Shorting Cap4
SS Stainless Steel Fasteners (external)
BransonSeries LBR
50-150W HPS, 50-175W MH
BallastWattage / Source Voltage
05 50W07 70W10 100W15 150W17 175W
S HPSM MH
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance/Lag NPFXH High Reactance/Lag HPFCA CWA Auto-RegCT CWI
Refer to ballast matrix on page 104for compatibility.
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VDT2 Dual Tap 120/240
Wired 240
Distribution
RO No Internal Refractor
R3 Type III1
R5 Type V1
Options
86 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
P R O D U C T O V E R V I E W
Features:Die-cast aluminum housing and spun aluminum hood for long-life performance
Optical assembly designed for maximum performance
Multi-gasketing to provide weatherproof protection of optical assembly for fullillumination performance
Hinged hood and captive screw latching provision afford quick, easy access toelectrical and optical area for relamping or servicing
Available with two different style hoods and an added scroll option for a moredecorative look
Cone mounting fitter with three set screws allows secure installation to polesizes 2-3/8" or 3" O.D.
Refractor available in tempered glass, acrylic and polycarbonate
Available in a variety of IES light distributions patterns
E39 mogul base socket standard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.16
Suitable for -30°C MH / -40°C HPS
Applications:StreetscapesWalkwaysPathwaysParks
DIMENSIONSDIMENSIONS
Effective Projected Area (EPA)The EPA for the Contempo Series 245 is 1.3 sq. ft.Approx. Wt. = 32 lbs.
Effective Projected Area (EPA)The EPA for the Decorative Scroll Option is 1.8 sq. ft.Approx. Wt. = 32 lbs.
ContempoSeries 24550-400W HPS, 70-400 MH
PREFERRED SELECTION CATALOG NUMBERS
245 10S RN 120 R5 AY245 15S RN 120 R5 AY245 25S CA MT1 R5 GL245 15S CA MT1 R5 AY
SCROLL DESIGN OPTION
87Product Guide
O R D E R I N G I N F O R M A T I O NExample: 2 4 5 1 0 S R N 1 2 0 R 3 G L S D P C
O R D E R I N G I N F O R M A T I O N
ContempoSeries 245
50-400W HPS, 70-400W MH
245 ContempoPost Top
05 50W07 70W10 100W13 100/150 Wired 10014 100/150 Wired 15015 150W17 175W25 250W40 400W
DistributionBallastWattage / SourceSeries
R2 Type IIR3 Type IIIR5 Type V
RN Reactor NormalPower Factor
RH Reactor HighPower Factor
XN High Reactance / Lag Normal Power Factor
XH High Reactance / Lag High Power Factor
CA CWA AutotransformerCT CWI AutotransformerSC SCWA
MR Mag Reg (3 coil)
Refer to ballast matrix onpage 105 for compatibility.
S HPSM MH
Notes:
1 Other colors available, please contact your localAmerican Electric Lighting representative
2 Voids UL/CSA not available in MT, TT, DT, voltages
3 PC, SH not available with NR option4 Available in HPS only5 Limited availability, please contact your local
American Electric Lighting representative6 Available in 250W maximum7 Available in 250W and 400W HPS and MH8 T3 option only available with 240, 480, DT2, DT4, MT29 Scroll color must be specified
Voltage
120 120V208 208V240 240V277 277V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240 wired 240V5T4 5-tap Wired 480V7
GL GlassAY Acrylic6
PY Polycarbonate6
Refer to optical matrix below forcompatibility
Optics
Paint1
(blank) Gray (standard)BK Black
WH WhiteBZ Bronze
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2 Position)8
ListingUL UL ListedCS CSA Certified
Fusing2
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle3
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter4
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Options
Hood Style (see line art)(blank) Style A
SD Style D
Misc.PC Photocontrol Included per
Voltage Specified3
SS Stainless Steel Hardware5H 50 Hertz Ballast Cycle5
NL NEMA LabelDD Decorative Scroll Design9
SH Shorting Cap3
R2 AY R3 AY R5 AY R2 PY R3 PY R5 PY R2 GL R3 GL R5 GL05S � � � � � � � � �07S � � � � � � � � �10S � � � � � � � � �15S � � � � � � � � �20S � � � � � � � � �25S � � � � � � � � �31S - - - - - - � � �40S - - - - - - � � �17M � � � � � � � � �25M � � � � � � � � �40M - - - - - - � � �
Optic Distribution
88 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
TwistPackSeries TWT50-250W HPS, 70-250W MH
P R O D U C T O V E R V I E W
DIMENSIONS
Features:Unique locking type feature with locking screw that allows easy removal ofoptical assembly from slipfitter casting
Slipfitter casting houses ballast. It will fit over a post having top diameter of3-1/2” (4”O.D.) or 3” (3-1/2”O.D.)
Slipfitter casting is secured to post by three Allen-head locking screws
Some components of the ballast (e.g. capacitors and/or ignitors) depending onwattage or type, may extend below the slipfitter casting and may have to fit inthe top of the pole
Aluminum hood covers are either 24” or 28” diameter
Refractors offered in IES Type II, and V distributions
Available in polycarbonate or acrylic refractors
Mogul base socket
Natural aluminum finish is standard, other colors available
NEMA type photocell receptacle is standard
CSA certified option available
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.16
Applications:Shopping mallsParks CampusesResidential streetsCondominiumsWalkways
Effective Projected Area (EPA)The EPA for the TwistPack H4 Hood is 1.40 sq. ft.The EPA for the TwistPack H8 Hood is 1.28 sq. ft.Approx. Wt. = 41 lbs.
PREFERRED SELECTION CATALOG NUMBERS
TWT 10S RN 120 R5 AY H8 CS NR ECTWT 15S RN 120 R5 AY H8 CS NR EC
H4 HOOD H8 HOOD
89Product Guide
TwistPackSeries TWT
50-250W HPS, 70-250W MH
O R D E R I N G I N F O R M A T I O N
TWT TwistPack 05 50W07 70W10 100W15 150W17 175W25 250W
DistributionBallastWattage / SourceSeries
R2 Roadway Type IIR5 Type V
CA CWA Autotransformer
CT CWIAutotransformer
RH Reactor High Power Factor
RN Reactor Normal Power Factor
XH High Reactance/LagHigh Power Factor
XN High Reactance/LagNormal Power Factor
Refer to ballast matrix onpage 105 for compatibility.
M Metal HalideS HPS
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
DT2 Dual Tap 120/240 Wired 240MT1 Multi-tap Wired 120MT2 Multi-tap Wired 240MT7 Multi-tap Wired 2775T4 5-tap Wired 4806
AY AcrylicPY Polycarbonate1
Optics
Options
PaintUP Unpainted (standard)BK BlackBZ BronzeGY Gray
WH White
Terminal BlockT2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2 Position)4
ListingCS CSA Certified
Supply WireP Pre-wired to Terminal BlockS Supply Wire Included in Carton
See page 118.
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol Receptacle3
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Starter5
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.PC Photocontrol Included per
Voltage Specified3
NL NEMA LabelSH Shorting Cap3
SS Stainless Steel Hardware
Example: T W T 1 5 S R N 1 2 0 R 5 A Y H 8
H4 24” hood2
H8 28” hood
Hood
Notes:
1 PY available in HPS only2 H4 available in 175W and below3 PC and SH not available with NR option4 T3 option only available with 240, 480, DT2, DT4, MT25 HPS only6 Available in 250W
P R O D U C T O V E R V I E W
90 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:INSTALLATION The post shall be provided with four, hot-dipgalvanized L-type anchor bolts to be installed on an 10" - 12"diameter bolt circle. A door shall be provided in the base foranchorage and wiring access. A grounding screw shall beprovided inside the base opposite the door.
MATERIALS The base shall be heavy wall, copper free, castaluminum produced from certified ASTM 356.1 ingot per ASTMB-179-95a or ASTM B26-95. The straight shafts shall be extrudedfrom aluminum, ASTM 6061 alloy, heat treated to a T6 temper. Thetapered shaft shall be extruded from aluminum, ASTM 6063 alloy,spun to a tapered shape, then heat treated to a T6 temper. Allhardware shall be tamper resistant stainless steel. Anchor bolts tobe completely hot-dip galvanized.
CONSTRUCTION The shaft shall be double welded to the basecasting and shipped as one piece for maximum structural integrity.The shaft shall be circumferentially welded inside the base castingat the top of the access door, and externally where the shaft exitsthe base. All exposed welds below 8’ shall be ground smooth. Allwelding shall be per ANSI/AWS D1.2-90. All welders shall becertified per Section 5 of ANSI/AWS D1.2-90.
DIMENSIONS The post shall be 8’- 16’ in height (depending oncustomer selection) with a 16" diameter base. The shaft diametervaries depending on shaft type selected. (See page 91.) At the topof the post, an integral 3" O.D. x 3" tenon with a transitional donutshall be provided for luminaire mounting.
Decorative PolesChadsworth SeriesCast Aluminum Posts Extruded Shaft
Applications:Streetscapes
Walkways
Pathways
Parks
91Product Guide
O R D E R I N G I N F O R M A T I O N
DIMENSIONS
Example: P X C H 1 6 1 2 S 5 A N B K A E L
OptionsShaft TypeHeightSeries
_________ Receptacles_________ Banner Arms_________ Flagpole Holders_________ Signage
(See Accessories section or contactyour local AEL representative.)
8’10’12’14’16’1
Notes:
1 16' height not available for S4, F4, or T4 (any4"Ø) Shaft Type
2 For finish specifications and color options, please contact your local American Electric Lighting representative
Finish2
AELManufacturing Code
S4 Smooth 4"ØS5 Smooth 5"ØF4 Fluted 4"ØF5 Fluted 5"ØT4 Tapered 4"-3"ØT5 Tapered 5"-3"Ø
ANBK BlackANDB BronzeANDG Dark Green
CM Custom MatchCS Custom Select
RAL colors
PX CH16 Chadsworth AEL
Decorative PolesChadsworth Series
Cast Aluminum Posts Extruded Shaft
P R O D U C T O V E R V I E W
92 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Decorative PolesNew Albany SeriesCast Aluminum Posts Extruded Shaft
Features:INSTALLATION The post shall be provided with four, hot-dipgalvanized L-type anchor bolts to be installed on an 12" diameter boltcircle. A door shall be provided in the base for anchorage and wiringaccess. A grounding screw shall be provided inside the base oppositethe door.
MATERIALS The base shall be heavy wall, copper free, cast aluminumproduced from certified ASTM 356.1 ingot per ASTM B-179-95a orASTM B26-95. The straight shafts shall be extruded from aluminum,ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shallbe extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape,then heat treated to a T6 temper. All hardware shall be tamperresistant stainless steel. Anchor bolts to be completely hot-dipgalvanized.
CONSTRUCTION The shaft shall be double welded to the base castingand shipped as one piece for maximum structural integrity. The shaftshall be circumferentially welded inside the base casting at the top ofthe access door, and externally where the shaft exits the base. Allexposed welds below 8’ shall be ground smooth. All welding shall beper ANSI/AWS D1.2-90. All welders shall be certified per Section 5 ofANSI/AWS D1.2-90.
DIMENSIONS The post shall be 8’- 16’ in height (depending oncustomer selection) with a 16" diameter base. The shaft diametervaries depending on shaft type selected. (See page 93.) At the top ofthe post, an integral 3" O.D. x 3" tenon with a transitional donut shall beprovided for luminaire mounting.
Smooth Fluted
Tapered
Applications:Streetscapes
Walkways
Pathways
Parks
93Product Guide
O R D E R I N G I N F O R M A T I O N
Example: P X N Y 1 7 1 2 S 5 A N B K A E L
Decorative PolesNew Albany Series
Cast Aluminum Posts Extruded Shaft
DIMENSIONS
Shaft TypeHeightSeries
8’10’12’14’16’1
S4 Smooth 4"ØS5 Smooth 5"ØF4 Fluted 4"ØF5 Fluted 5"ØT4 Tapered 4"-3"ØT5 Tapered 5"-3"Ø
PX NY17 New Albany
Notes:
1 16' height not available for S4, F4, or T4 (any 4"Ø) Shaft Type.
2 For finish specifications and color options, please contact your local American Electric Lighting representative.
Options
_________ Receptacles_________ Banner Arms_________ Flagpole Holders_________ Signage
(See Accessories section or contactyour local AEL representative.)
Finish2
AELManufacturing Code
ANBK BlackANDB BronzeANDG Dark Green
CM Custom MatchCS Custom Select
RAL colors
P R O D U C T O V E R V I E W
94 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:INSTALLATION The post shall be provided with four, hot-dipgalvanized L-type anchor bolts to be installed on an 9.5" diameterbolt circle. A door shall be provided in the base for anchorage andwiring access. A grounding screw shall be provided inside the baseopposite the door.
MATERIALS The base shall be heavy wall, copper free, castaluminum produced from certified ASTM 356.1 ingot per ASTMB-179-95a or ASTM B26-95. The straight shafts shall be extrudedfrom aluminum, ASTM 6061 alloy, heat treated to a T6 temper. Thetapered shaft shall be extruded from aluminum, ASTM 6063 alloy,spun to a tapered shape, then heat treated to a T6 temper. Allhardware shall be tamper resistant stainless steel. Anchor bolts tobe completely hot-dip galvanized.
CONSTRUCTION The shaft shall be double welded to the basecasting and shipped as one piece for maximum structural integrity.The shaft shall be circumferentially welded inside the base castingat the top of the access door, and externally where the shaft exitsthe base. All exposed welds below 8’ shall be ground smooth. Allwelding shall be per ANSI/AWS D1.2-90. All welders shall becertified per Section 5 of ANSI/AWS D1.2-90.
DIMENSIONS The post shall be 8’- 14’ in height (depending oncustomer selection) with a 16" diameter base. The shaft diametervaries depending on shaft type selected. (See page 95.) At the top ofthe post, an integral 3" O.D. x 3" tenon with a transitional donut shallbe provided for luminaire mounting. .
Applications:Streetscapes
Walkways
Pathways
Parks
Decorative PolesStatesboro SeriesCast Aluminum Posts Extruded Shaft
95Product Guide
O R D E R I N G I N F O R M A T I O N
Example: P X S 9 1 2 S 4 A N B K A E L
DIMENSIONS
Decorative Poles Statesboro Series
Cast Aluminum Posts Extruded Shaft
Shaft TypeHeightSeries
8’10’12’14’
S4 Smooth 4"ØF4 Fluted 4"ØT4 Tapered 4"-3"Ø
PX S9 Statesboro
Options
_________ Receptacles_________ Banner Arms_________ Flagpole Holders_________ Signage
(See Accessories section or contactyour local AEL representative.)
Finish2
AELManufacturing Code
ANBK BlackANDB BronzeANDG Dark Green
CM Custom MatchCS Custom Select
RAL colors
P R O D U C T O V E R V I E W
96 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:INSTALLATION The post shall be provided with four, hot-dipgalvanized L-type anchor bolts to be installed on an 12" diameter boltcircle. A door shall be provided in the base for anchorage and wiringaccess. A grounding screw shall be provided inside the base oppositethe door.
MATERIALS The base shall be heavy wall, copper free, cast aluminumproduced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The straight shafts shall beextruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper.The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy,spun to a tapered shape, then heat treated to a T6 temper. Allhardware shall be tamper resistant stainless steel. Anchor bolts to becompletely hot-dip galvanized.
CONSTRUCTION The shaft shall be double welded to the base castingand shipped as one piece for maximum structural integrity. The shaftshall be circumferentially welded inside the base casting at the top ofthe access door, and externally where the shaft exits the base. Allexposed welds below 8’ shall be ground smooth. All welding shall beper ANSI/AWS D1.2-90. All welders shall be certified per Section 5 ofANSI/AWS D1.2-90.
DIMENSIONS The post shall be 8’- 16’ in height (depending oncustomer selection) with a 16" diameter base. The shaft diametervaries depending on shaft type selected. (See page 97.) At the top ofthe post, an integral 3" O.D. x 3" tenon with a transitional donut shall beprovided for luminaire mounting. .
Applications:Streetscapes
Walkways
Pathways
Parks
Decorative PolesWaycross SeriesCast Aluminum Posts Extruded Shaft
97Product Guide
O R D E R I N G I N F O R M A T I O N
Example: P X W 1 7 1 2 S 5 A N B K A E L
DIMENSIONS
Shaft TypeHeightSeries
8’10’12’14’16’1
AELManufacturing Code
S4 Smooth 4"ØS5 Smooth 5"ØF4 Fluted 4"ØF5 Fluted 5"ØT4 Tapered 4"-3"ØT5 Tapered 5"-3"Ø
PX W17 Waycross AEL
Notes:
1 16' height not available for S4, F4, or T4 (any 4"Ø) Shaft Type.
2 For finish specifications and color options, please contact your local American Electric Lighting representative.
Options
_________ Receptacles_________ Banner Arms_________ Flagpole Holders_________ Signage
(See Accessories section or contactyour local AEL representative.)
Finish2
ANBK BlackANDB BronzeANDG Dark Green
CM Custom MatchCS Custom Select
RAL colors
Decorative PolesWaycross Series
Cast Aluminum Posts Extruded Shaft
P R O D U C T O V E R V I E W
98 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Receptacle with Wet Location While Closed Cover
Catalog part # FG-S
SPECIFICATIONS A 20 amp, 125 volt, ground fault circuitinterrupter duplex receptacle shall be mounted in the post.The receptacle shall be UL Listed according to E-48380 andUL 943 Class A and UL 498. The receptacle shall have a castaluminum, UL Listed cover that is suitable for wet locationswhile not in use. The receptacle and cover shall mount to anoutlet opening, in the post shaft, with a gasket and stainlesssteel screws.
Receptacle with Small, In-Use Wet Location Cover
Catalog part # FGIUS-S
SPECIFICATIONS A 20 amp, 125 volt, ground fault circuitinterrupter duplex receptacle shall be mounted in the post.The receptacle shall be UL Listed according to E-48380 andUL 943 Class A and UL 498. The receptacle shall have a castaluminum, lockable, UL Listed cover that is suitable for wetlocations while in use and complies with NEC Article 410-57(b). The cover shall accept most common cord sets up to3/8” diameter (14/3). The receptacle and cover shall mount toan outlet opening, in the post shaft, with a gasket andstainless steel screws.
Receptacle with Large, In-Use Wet Location Cover
Catalog part # FGIUL-S
SPECIFICATIONS A 20 amp, 125 volt, ground fault circuitinterrupter duplex receptacle shall be mounted in the post.The receptacle shall be UL Listed according to E-48380 andUL 943 Class A and UL 498. The receptacle shall have a castaluminum, lockable, UL Listed cover that is suitable for wetlocations while in use and complies with NEC Article 410-57(b). The cover shall accept most common cord sets up to1/2” diameter (12/3). The receptacle and cover shall mount toan outlet opening, in the post shaft, with a gasket andstainless steel screws.
Decorative PolesWeatherproof ReceptaclesExternal, Post Shaft Location
Features:INSTALLATION External receptacles are typically installed above pedestrian level for special event uses and decorative seasonal lighting.
CONSTRUCTION Ground fault circuit interrupter receptacles. Test/Reset buttons on face of receptacles. All cast aluminum covers,not plastic. (Paintable to match post color). Weatherproof “While-in-Use” covers in two sizes.
99Product Guide
P R O D U C T O V E R V I E W
Decorative PolesWeatherproof Receptacles
External, Post Shaft Location
Features:INSTALLATION Internal receptacles are typically installed for use by authorized personnel for special events and owner maintenance purposes.
CONSTRUCTION Ground fault circuit interrupter receptacles. Test and reset buttons on face of receptacles. All cast aluminum covers, not plastic.
Receptacle with Weatherproof Box and Cover
Catalog part # RB/GFI/WPC
SPECIFICATIONS A 20amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted inside the post base, facing toward theaccess door. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall be mounted in a castaluminum box and cover that is suitable for wet locations while not in use. The receptacle and cover shall mount to a outlet box with a gasketand stainless steel screws.
100 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
B A L L A S T M A T R I C E S
Decorative and Post Top Lighting
Valiant
Valiant continued
American Revolution Deluxe Series
Watts 120 208 240 277 347 480 DT2 MT105S RH, RN - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XH, XN, CA, CT XH, XN, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XH, XN, CA, CT XH, XN, CA, CT10M XH, XN, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH13S RH, RN - - - - - - -14S RH, RN - - - - - - -15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XH, XN, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA
Watts MT2 MT7 TT305S - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH13S - - -14S - - -15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA
American Revolution Deluxe Series continued
Watts 120 208 240 277 347 480 DT2 MT105S RN, RH - - - - - - -07S CA, CT, RH, RN XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT 07M XH, XN XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XH, XN, CA, CT XN, XH, CA, CT10M XH, XN, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH13S RN, RH - - - - - - -15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA20S CA CA RN, RH, CA CA - CA CA CA25S XN, XH, CA CA XN, XH, CA CA CA CA XN, XH, CA CA25M CA CA CA CA - CA CA CA
Watts MT2 MT7 TT305S - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH13S - - -15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA20S CA CA CA25S CA CA CA, CT25M CA CA CA, CT
101Product Guide
B A L L A S T M A T R I C E S
Decorative and Post Top Lighting
American Revolution Series 247
Watts 120 208 240 277 347 480 DT2 MT105S RH, RN - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XH, XN, CA, CT XH, XN, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XH, XN, CA, CT XH, XN, CA, CT10M XH, XN, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH13S RH, RN - - - - - - -14S RH, RN - - - - - - -15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XH, XN, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA
Watts MT2 MT7 TT305S - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH13S - - -14S - - -15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA
American Revolution Series 247 continued
American Revolution Cutoff Series 247Watts 120 208 240 277 347 480 DT2 MT105S RH, RN - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XH, XN, CA, CT XH, XN, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XH, XN, CA, CT XH, XN, CA, CT10M XH, XN, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH13S RH, RN - - - - - - -14S RH, RN - - - - - - -15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XH, XN, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA
Watts MT2 MT7 TT305S - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH13S - - -14S - - -15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA
American Revolution Cutoff Series 247 continued
102 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
B A L L A S T M A T R I C E S
Decorative and Post Top Lighting
Wattage 120 208 240 277 347 480 DT1 MT105S RN,RH - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT10M XN, XH, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA
Watts 120 208 240 277 480 DT2 MT1 MT2 MT705S RN - - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA CA XN, XH, CA, CT CA, CT CA, CT CA, CT10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT CA N, XH, CA, CT CA, CT CA, CT CA, CT15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT CA XN, XH, CA, CT CA, CT CA, CT CA, CT17M CA CA CA CA CA - - CA CA
Bainbridge Series 870
Georgian Series GRP
Georgian Series GRP continued
Wattage MT2 MT7 TT305S - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA
Marietta Series LMD
Wattage 120 208 240 277 347 480 DT2 MT105S RN,RH - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT10M XN, XH, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA25S XN, XH, CA CA XN, XH, CA CA CA CA XN, XH, CA CA25M CA CA CA CA - CA CA CA
Marietta Series LMD continued
Wattage MT2 MT7 TT305S - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA25S CA CA CA, CT25M CA CA CA, CT
103Product Guide
B A L L A S T M A T R I C E S
Decorative and Post Top Lighting
Sumter Series LSH
Sumter Series LSH continued
Wattage 120 208 240 277 347 480 DT2 MT105S RN,RH - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT10M XN, XH, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA25S XN, XH, CA CA XN, XH, CA CA CA CA XN, XH, CA CA25M CA CA CA CA - CA CA CA
Wattage MT2 MT7 TT305S - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA25S CA CA CA, CT25M CA CA CA, CT
Cresthill Series LCR - Classic, Sphere and Centennial
Wattage 120 208 240 277 347 480 DT2 MT105S RN,RH - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT10M XN, XH, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA
Cresthill Series LCR - Classic, Sphere and Centennial continued
Wattage MT2 MT7 TT305S - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA
104 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
B A L L A S T M A T R I C E S
Decorative and Post Top Lighting
Cresthill Series LCR - Glass
Cresthill Series LCR - Glass continued
Wattage 120 208 240 277 347 480 DT2 MT105S RN,RH - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT10M XN, XH, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA25S XN, XH, CA CA XN, XH, CA CA CA CA XN, XH, CA CA25M CA CA CA CA - CA CA CA
Wattage MT2 MT7 TT305S - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH XN, XH XN, XH15S XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH17M CA CA CA25S CA CA CA, CT25M CA CA CA, CT
Watts 120 208 240 277 347 480 DT2 MT1 MT2 MT7 TT305S RH,RN - - - - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH XN, XH XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA XN, XH, CT XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH, CA XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH XN, XH XN, XH XN, XH15S RH, RN, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH XN, XH XN, XH XN, XH17M CA CA CA CA CA CA CA CA CA CA CA
Branson LBR
Watts 120 208 240 277 347 480 DT2 MT1 MT2 MT7 TT305S RH,RN - - - - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH XN, XH XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA XN, XH, CT XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT10M XN, XH, CA XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH XN, XH XN, XH XN, XH15S RH, RN, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT -15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH XN, XH XN, XH XN, XH17M CA CA CA CA CA CA CA CA CA CA CA
Lexington LLX
105Product Guide
B A L L A S T M A T R I C E S
Decorative and Post Top Lighting
Wattage 120 208 240 277 347 480 DT2 MT105S RN,RH - - - - - - -07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT10M XN, XH, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH XN, XH15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA - XN, XH, CA, CT15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH XN, XH17M CA CA CA CA CA CA CA CA20S CA CA RN, RH, CA CA - CA CA CA 25S XN, XH, CA CA XN, XH, CA CA CA CA XN, XH, CA CA25M CA CA CA CA CA, CT, SC CA, SC CA, CT, SC CA, SC
Wattage MT2 MT7 TT3 5T405S - - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT -07M XN, XH XN, XH XN, XH -10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT -10M XN, XH XN, XH XN, XH -15S XN, XH, CA, CT XN, XH, CA, CT - -15M XN, XH XN, XH XN, XH -17M CA CA CA -20S CA CA CA -25S CA CA CA, CT CA25M CA, SC CA, SC CA, CT CA
TwistPack Series TWT
TwistPack Series TWT continued
Contempo Series 245
Contempo Series 245 continued
Watts 120 208 240 277 347 480 DT205S RN, RH - - - - - - 07S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT07M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH10S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT XN, XH, CA XN, XH, CA, CT10M XN, XH, CA XN, XH XN, XH XN, XH, CA XN, XH - XN, XH13S RN, RH - - - - - -14S RN, RH - - - - - -15S RN, RH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - XN, XH, CA -15M XN, XH XN, XH XN, XH XN, XH XN, XH - XN, XH17M CA CA CA CA CA CA CA20S CA CA RN, RH, CA CA - CA CA25S XN, XH, CA CA XN, XH, CA CA CA CA XN, XH, CA25M CA CA CA CA CA, CT, SC CA, SC CA, CT, SC31S - - - - - - -40S CA, CT CA, CT CA, CT CA, CT CA CA CA, CT40M CA, CT CA CA, CT CA - CA, SC CA, CT
Watts MT1 MT2 MT7 TT3 5T405S - - - - -07S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT -07M XN, XH XN, XH XN, XH XN, XH -10S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT XN, XH, CT -10M XN, XH XN, XH XN, XH XN, XH -13S - - - - -14S - - - - -15S XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT - -15M XN, XH XN, XH XN, XH XN, XH -17M CA CA CA CA -20S CA CA CA CA -25S CA CA CA CA, CT CA25M CA, SC CA, SC CA, SC CA, CT CA31S - - - - -40S - - - - CA40M CA CA CA - CA
106 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
NOTES
SECURITY LIGHTING
American Electric Lighting®
NEMA Head Series 11 ...........................................108
NEMA Head Package Series 11 PKG .................110
Series 11 “L” Package...........................................112
Dusk To Dawn Series DTD....................................114
Series 165 ................................................................116
Accessories ............................................................118
Ballast Matrices .....................................................119
107
P R O D U C T O V E R V I E W
108 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
NEMA Head Series 11Security Lighting50-250W HPS, 100-175W MH
DIMENSIONS
Features:Die-cast aluminum head meets NEMA dimension standards
For quick easy installation of mast arm, a cast-in external slipfitter is used for asecure mounting
Available in a variety of IES light distribution patterns , including full cutoff
Tools are not required to install reflector and refractor
Tool-less adjustable photocontrol mount
Available for arm size 1-1/4" (standard) and 2" fitter
Open bottom acrylic, polycarbonate, or glass
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.6, C136.10
Applications:Security areasStorage yardsLoading areasReceiving areas
Full Cutoff (FC)Vented Bottom Acrylic (VBA)
Approx. Wt. = 16 lbs.
Approx. Wt. = 16 lbs.
PREFERRED SELECTION CATALOG NUMBERS
11 10S RN 120 R5 BA SW511 10S RN 120 RO LO11 15S RN 120 R5 BA SW511 15S RN 120 RO LO11 10M XN 120 R5 BA MDO
109Product Guide
Example: 1 1 1 0 S R N 1 2 0 R 5 B A
O R D E R I N G I N F O R M A T I O N
NEMA Head Series 11Security Lighting
50-250W HPS, 100-175W MH
11 NEMA Head
R2 Type IIR3 Type IIIR5 Type VRO No Optics (not for
MH)
RN Reactor NormalPower Factor
XN High Reactance / Lag Normal Power Factor
CA CWA, Auto Reg.
120 120V208 208V240 240V277 277V
MT1 120V Multi-tapMT2 240V Multi-tapMT7 277V Multi-tap
05 50W07 70W10 100W15 150W17 175W25 250W
S HPSM MH
Mast Arm2
M4 24" ArmM3 30" Arm
Photocontrol Receptacle(blank) Standard
NR No Photocontrol Receptacle3
Supply Wire4
SW5 Pre-wire 5'PW5 Wired to Terminal Block 5'
(For more options see page 118)
Starter5
(blank) Open Board StandardEC Encapsulated Starter
LO Less OpticsBA Open Bottom Acrylic6
BP Open Bottom PolycarbonateFC Full Cutoff1,7,8
BG Open Bottom Glass6
VBA Vented Bottom Acrylic(required for mogul base MHlamp only)
Options
Fitter Size(blank) 1-1/4“ Fitter
H2 2” Fitter set for 1-1/4“Lamp
LC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Misc.PC Photocontrol Included per
Voltage SpecifiedNL NEMA LabelLA Lightning ArrestorSH Shorting Cap5
MDO Medium Base Socket,Open Rated(100W and 150W MH only)7
Notes:
1 Available in R5 distribution only2 Available in 1 ¼" aluminum pipe only3 Not available with PC or DPC option4 Standard with #14 copper solid, black-white, THHN5 HPS only6 MH version requires open rated socket (MDO)7 Requires open rated lamp8 Nighttime FriendlyTM optic
DistributionBallast Voltage
Optics
Wattage / SourceSeries
Refer to the ballast matrix onpage 119 for compatibility.
P R O D U C T O V E R V I E W
110 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:Die-cast aluminum head meets NEMA dimension standards
For quick easy installation of mast arm, a cast-in external slipfitter is used for asecure mounting
Available in a variety of IES light distributions patterns including full cutoff
Tools are not required to install reflector and refractor
Includes 24”, 1-1/4” diameter mast arm with welded brackets, lamp,photocontrol, 5’ of supply wire, and hardware
All electrical components warranted by American Electric Lighting's 6-yearguarantee
All components in single carton
Open bottom acrylic, polycarbonate, or glassSuitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.6, C136.10
Applications:Security areasStorage yardsLoading areasReceiving areas
NEMA Head Package Series 11 PKGSecurity Lighting50-250W HPS, 100-175W MH
Note: Package includes welded bracket, 24” mast arm 1-1/4”diameter, lamp, photocontrol, 5’ of supply wire and hardware.Approx. Wt. = 18 lbs.
DIMENSIONS
PREFERRED SELECTION CATALOG NUMBERS
11PKG 10S RN 120 R5 BA EC11PKG 15S RN 120 R5 BA EC11PKG 10M XN 120 R5 BA MDO
Full Cutoff (FC)
Vented Bottom Acrylic (VBA)
111Product Guide
Example: 1 1 P K G 1 5 S R N 1 2 0 R 5 B A E C
O R D E R I N G I N F O R M A T I O N
NEMA Head Package Series 11 PKGSecurity Lighting
50-250W HPS, 100-175W MH
11PKG NEMA Head Package
R2 Type IIR3 Type IIIR5 Type V
CA CWA, Auto Reg.1RN Reactor/Normal
Power FactorXN High Reactance/Lag
Normal Power Factor
05 50W07 70W10 100W15 150W17 175W25 250W
S HPS M MH
Optics
Notes:
1 Available in 175W MH only2 Available in R5 distribution only3 MH version requires open rated lamp4 Available in HPS only5 Open rated lamp supplied6 Nighttime FriendlyTM optic
DistributionBallast VoltageWattage / SourceSeries
BA Open BottomAcrylic3
BP Open BottomPolycarbonate
FC Full Cutoff2,3,6
BG Open Bottom Glass
VBA Vented Bottom Acrylic (required for MH)
Photocontrol (per voltage specified)(blank) Photocontrol (standard)
Starter4
(blank) Open Board (standard)EC Encapsulated Starter
Options
Lamp(blank) Lamp Included, Clear
LD Lamp Included, Deluxe/Coated
Misc.NL NEMA Label
MDO Medium Base Socket,Open Rated(100W and 150W MH only)5
120 120V208 208V240 240V277 277V
MT1 120V Multi-tapMT8 208V Multi-tapMT2 240V Multi-tapMT7 277V Multi-tapRefer to the ballast matrix on
page 119 for compatibility.
P R O D U C T O V E R V I E W
112 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Applications:Rural areasArea lightingSmall businesses
Features:Die-cast aluminum head meets NEMA dimension standards
For quick easy installation of mast arm, a cast-in external slipfitter is used fora secure mounting
Includes 18” mast arm, lamp, photocontrol, pre-wire, and hardware
All components in single carton
Open bottom acrylic
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.6, C136.10
UL Listed for wet locations
Series 11 “L” PackageSecurity Lighting50-150W HPS
Note: Package includes 18” mast arm, lamp, photocontrol, pre-wire, and hardware.Approx. Wt. = 18 lbs.
DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS
11L 10S RN 120 R5 BA11L 15S RN 120 R5 BA
113Product Guide
Example: 1 1 L 1 5 S X N 1 2 0 R 5 B A
O R D E R I N G I N F O R M A T I O N
11L SecurityPackage
R5 Type VRN Reactor Normal Power Factor
XN High Reactance / Lag Normal Power Factor
05 50W07 70W10 100W15 150W
S HPS BA Open Bottom Acrylic
OpticsDistributionBallast VoltageWattage / SourceSeries
Series 11 “L” Package Security Lighting
50-150W HPS
Package includes 18” mast arm, lamp, photocontrol,pre-wire and hardware
Photocontrol (per voltage specified)(blank) Photocontrol (standard)
Mast ArmWA Welded Arm (24” mast arm)1
Listing(blank) UL Listed (standard)
CS CSA Certified
Options
Refer to the ballast matrix onpage 119 for compatibility.
120 120V208 208V240 240V277 277V
MT1 120V Multi-tapMT2 240V Multi-tapMT7 277V Multi-tap
Notes:1 Available in 1-1/4” aluminum pipe only
P R O D U C T O V E R V I E W
114 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:Ballast is completely enclosed in arm, but is readily accessible
All components in single carton
Refractor available in open bottom acrylic, or polycarbonate
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH & / -40°C HPS
Complies with ANSI: C136.2, C136.10
Applications:Rural areasSmall businessesStorage lots
Dusk to Dawn Series DTDSecurity Lighting150-400W HPS, 175-400W MH
Approx. Wt. = 23 lbs.
PREFERRED SELECTION CATALOG NUMBERS
DTD 15S RH 120 R5 BA CS LC PC NLDTD 25S XN 120 R5 BA CS LC PC
115Product Guide
Example: D T D 1 5 S R H 1 2 0 R 5 B A
O R D E R I N G I N F O R M A T I O N
Dusk to Dawn Series DTDSecurity Lighting
150-400W HPS, 175-400W MH
DTD Dusk to Dawn R5 Type VRN Reactor Normal Power FactorRH Reactor High Power FactorCA CWA Auto RegCT CWIXN High Reactance (Lag) Normal
Power FactorXH High Reactance (Lag) High
Power Factor
120 120V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347V
15 150W17 175W25 250W40 400W
S HPSM MH1
Standard Listing (blank) No Listing
CS CSA Certified
PhotocontrolNR No Photocontrol Receptacle2
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Notes:
1 Requires open rated lamp2 Not available with PC or SH option
DistributionBallast VoltageWattage / SourceSeries
BA Open BottomAcrylic
Optics
Options
MiscPC Photocontrol Included
per Voltage SpecifiedNL NEMA LabelSH Shorting Cap
Refer to the ballast matrix onpage 119 for compatibility.
P R O D U C T O V E R V I E W
116 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Applications:Parking lotsRoadwaysCommercial environmentsOffice communities
Features:One piece die cast aluminum head and arm configuration for long-life stabilityand performance
Optical assembly utilizes dual latch mounting for quick, easy and secureinstallation
Electrical components mounted to power door for installation and maintenance convenience
Gray polyester powder coated housing finish is standard
Refractors available in open bottom acrylic, polycarbonate and glass
NEMA Label standard
Open board starter standard on HPS units
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.15, C136.6
6’ of supply wire and hardware included
Series 165Security Lighting – Ballast-In-Arm50-400W HPS, 175-400W MH
Approx. Wt. = 35 lbs.
PREFERRED SELECTION CATALOG NUMBERS
165 25S XN 120 R5 BA LC PC 165 20S XN 120 R5 BA PJ0 LC165 40S CA MT1 R5 BG LC PC165 40M SC MT1 R5 BG LC PC
117Product Guide
O R D E R I N G I N F O R M A T I O N
165 Ballast-inArm
05 50W07 70W10 100W15 150W17 175W20 200W25 250W40 400W
DistributionBallastWattage / SourceSeries
R3 Area Type IIIR5 Area Type V
RN Reactor NormalPower Factor
RH Reactor High PowerFactor
XN High Reactance /Lag NormalPower Factor
XH High Reactance /Lag HighPower Factor
CA CWA Auto RegCT CWISC SCWA
MR Mag Reg
S HPSM MH
Notes:
1 Not available in R4 distribution2 T3 option only available with 240, 480, DT2, DT4, MT23 Not available with MT4 PC option not available with NR option5 Available in HPS only
Voltage
120 120V208 208V240 240V277 277V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277V
Terminal Block(blank) Hard Wired (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)2
Fusing3
SF Single Fuse (120, 277V)DF Double Fuse (208, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle4
Options
Starter(blank) Open Board (standard)
EC Encapsulated Starter5
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Misc.PC Photocontrol Included per
Voltage Specified4
TL Tool-less EntrySS Stainless Steel Hardware
Optics
BA Open BottomAcrylic
BP Open BottomPolycarbonate
BG Open BottomGlass1
Series 165Security Lighting – Ballast-In-Arm
50-400W HPS, 175-400W MH
Example: 1 6 5 4 0 S C A 1 2 0 R 5 B A L C P C
Refer to the ballast matrix onpage 119 for compatibility.
118 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
P Pre-wired to terminal blockS Supply wire included in carton
A #10 CU Solid B/WB #10 CU Solid B/BC #10 CU Solid B/B/WD #10 CU Stranded B/WE #10 CU Stranded B/BF #10 CU Stranded B/B/WG #12 CU Solid B/WH #12 CU Solid B/BI #12 CU Solid B/B/WDJ #12 CU Stranded B/WK #12 CU Stranded B/BL #12 CU Stranded B/B/W
W #14 CU Solid B/WM #14 CU Solid B/BN #14 CU Solid B/B/W
4 4’5 5’6 6’8 8’0 10’
ExamplesSW5 = 5’ of #14 CU. Solid, B/W wire supplied in cartonPW5 = 5’ of #14 CU. Solid, B/W pre-wired to terminal blockPD0 = 10’ of #10 CU. Stranded, B/W pre-wire to terminal block
WIR
E SI
ZE A
ND
SPEC
IFIC
ATIO
NLE
NGT
H
P R E - S U P P L Y W I R E
Accessories
119Product Guide
B A L L A S T M A T R I C E S
Nema Head Package Series 11PKGWatts 120 208 240 277 MT1 MT2 MT705S RN XN XN XN XN XN XN07S RN XN XN XN XN XN XN10S RN XN XN XN XN XN XN10M XN - - XN - - -15S RN XN XN XN XN XN XN17M CA CA CA CA CA CA CA25S XN - RN - - - -
Nema Head 11Watts 120 208 240 277 MT1 MT2 MT705S RN XN XN XN XN XN XN07S RN XN XN XN XN XN XN10S RN XN XN XN XN XN XN10M XN - - - - - -15S RN XN XN XN XN XN XN17M CA CA CA CA CA CA CA25S XN - RN - - - -
Series 11L PackageWatts 120 208 240 277 MT1 MT2 MT7 TT305S RN XN XN XN XN XN XN -07S RN XN XN XN XN XN XN XN10S RN XN XN XN XN XN XN XN15S RN XN XN XN XN XN XN XN
Security Lighting
Dusk To DawnWatts 120 240 277 480 MT1 MT2 MT7 TT315S RN,RH,CA,CT,MR CA,CT,XN,XH,MR XN,XH,CA CA,MR XN,XH,CA,CT XN,XH,CA,CT XN,XH,CA,CT XN,XH17M CA CA CA CA CA CA CA -25S XH,XN,CA,CT,MR RN,RH,CA,CT,MR CA,CT CA,MR CA,CT CA,CT CA,CT CA40S CA,CT,XN,XH RH,RN,CA,CT CA,CT CA CA,CT CA,CT CA,CT CA
Series 165Watts 120 208 240 277 480 MT1 MT2 MT705S RH,RN XH,XN XH,XN XH,XN - XH,XN XN,XH XN,XH07S RH,CA,CT,RN,MR XH,CA,CT,XN XH,CA,CT,MR,XN XH,CA,XN MR XH,XN,CA XH,XN,CA, XH,XN,CA,10S CA,CT,MR,RH,RN XH,CA,CT,XN XH,CA,CT,MR,XN CA,XH,XN CA CA,XN,XH CA,XN,XH CA,XN,XH15S RN,RH,CA,CT,MR CA,CT,XN,XH CA,CT,XN,XH,MR XN,XH,CA CA,MR XN,XH,CA,CT XN,XH,CA,CT XN,XH,CA,CT17M CA CA CA CA CA CA CA CA25M CA,CT,SC CA,CT,SC CA,CT,SC CA,SC CA,CT CA,SC CA,SC CA,SC20S CA, CT, XN, XH MR CA, CT CA,CT,RN,RH,MR CA,CT,MR CA,CT,MR CT,CA CT,CA CT,CA25S XH,XN,CA,CT CA,CT RN,RH,CA,CT CA,CT CA CA,CT CA,CT CA,CT40S CA,CT,XN,XH CA,CT RH,RN,CA,CT CA,CT CA CA,CT CA,CT CA,CT40M CA CA CA CA CA CA,SC CA CA
120 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
NOTES
AREA LIGHTING
ASA ........................................................................122
PES ........................................................................124
PEM ........................................................................126
VMR ........................................................................128
VLR ........................................................................130
AVL-BIA ................................................................132
AVL ..........................................................................134
LuxMaster® Luminaire Series 53 ......................136
LuxMaster® Luminaire Series 153 ....................138
LuxMaster® Classic Series LS............................140
LuxMaster® Classic Series LM ..........................142
Accessories ..........................................................144
Ballast Matrices....................................................148
American Electric Lighting®
121
P R O D U C T O V E R V I E W
122 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Applications:Parking lotsRoadwaysCommercial environmentsOffice communities
Features:Superior electrical and thermal performance backed by AEL’s 6-year electricalwarranty
Industry leading Dark To LightTM electronic photocontrol included with PCoption
Stainless steel external hardware available
Impact resistant flat glass
Rugged die-cast aluminum enclosure, polyester powder coat paint finish
Rotatable and interchangeable R2, R3 and R5 hydroformed optics, segmentedforward throw reflector with R4 distribution
Aluminum extruded arms available in 4” or 9” mounting for square, round orwood poles
External horizontal mast arm fitter mounting option
Tool-less entry latching option
Tool-less PEC receptacle, standard
Housing sealed with high temperature silicone gasketing
Terminal block and phosphor bronze PEC receptacle contacts, standard
Effective Projected Area (EPA)The EPA for the ASA is 1.7 sq. ft. with a 4”arm; 1.8 sq. ft. with a 9” armApprox. Wt = 37 lbs.
ASAArea Lighting70-400W HPS, 70-400W MH
NEW
PREFERRED SELECTION CATALOG NUMBERS
ASA 24S CA MT7 R2 SP4 SHASA 40M SC MT1 R3 SP4 LC PCASA 40M SC MT1 R5 SP4 LC PC
123Product Guide
O R D E R I N G I N F O R M A T I O N
Example: A S A 4 0 M C A M T 1 R 3 S P 4 L C P C
Refer to the ballast matrix onpage 148 for compatibility.
ASA Architectural Site Area Light
07 70W10 100W15 150W17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 250W24 250/400W
Wired 400W
DistributionBallastWattage / SourceSeries
R2 Area Type IIR3 Area Type IIIR4 Type IV Forward
Throw, Sharp Cutoff1
R5 Type V, Symmetric
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance(Lag) Normal
XH High Reactance(Lag) High
CA CWA (Auto Reg)CT CWISC SCWA
S HPSM MH
Notes:
1 Segmented reflector, not rotatable2 Other colors available, please contact
your local American Electric Lighting representative
3 Not available for 120V fixtures4 PC & SH not available with NR option5 HPS only6 Not available in MT or TT voltages7 Limited availability, please contact
your local American Electric Lightingrepresentative
8 Order less mounting for mast arm mount
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347V5T4 5-Tap Wired 480V
Paint2
(blank) Bronze (standard)BK BlackGY Gray
WH White
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)3
Listing(blank) UL Listed (standard)
CS CSA CertifiedXL No Listing
Photocontrol Receptacle(blank) Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle4
Starter5
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Board Plug-in
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Fusing6
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Misc.PC Photocontrol Included per
Voltage SpecifiedTL Tool-less EntrySS Stainless Steel Fasteners
(external)5H 50 Hertz Ballast Frequency7
NL NEMA LabelSH Shorting Cap
(blank) Less Mounting8
SP4 Square, 4”SP9 Square, 9”RP4 Round, 4”RP9 Round, 9”
WW4 Wood, 4”WW9 Wood, 9”
Mounting
ASAArea Lighting
70-400W HPS, 70-400W MH
Shipped SeparateRKASA EF BZ External Mast
Arm Mount
P R O D U C T O V E R V I E W
124 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Applications:Parking lotsStreet lightingParking areas
Features:Rugged, heavy-gauge, premium extruded aluminum housing
Square shape, seam-welded and internally sealed for weathertight integrity
Standard finish is dark bronze corrosion resistant polyester powder
Anodized, segmented reflectors for uniformity and control
Reflectors are tool-less, rotatable and interchangeable
3 cutoff distributions available, R2, R3 and FT
Natural anodized, extruded aluminum door frame sealed to housing by siliconeclosed-cell gasket. Can be hinged from any of the four sides
Lens is .125” thick, impact-resistant tempered glass
Rugged die-cast aluminum enclosure, polyester powder coat paint finish
Extruded 4” aluminum arm for square pole mounting is standard, optionalmountings available
High reactance, high power factor for 150W and below. Removable power trayand positive-locking disconnect plug
Medium-base socket for 150W MH and below. Mogul-base porcelain socketwith copper alloy, nickel-plated screw shell and center contact
Terminal block and phosphor bronze PEC receptacle contacts, standard
UL Listed 1500W-600V. 4KV pulse rated
UL Listed, standard. CSA Certified or NOM Certified. UL Listed for wetlocations
Effective Projected Area (EPA)The EPA for the PES is 1.3 sq. ft.Approx. Wt = 26.6 lbs.
PESArea Lighting70-150W HPS, 100-250W MH
NEW
Available Summer 2008
PREFERRED SELECTION CATALOG NUMBERS
PES 10M XH MT1 FT SP4 LC PCPES 10S CA MT1 R3 SP9 LC PC
125Product Guide
O R D E R I N G I N F O R M A T I O N
Example: P E S 1 5 S R N 1 2 0 R 2 S P 9 P C
Refer to the ballast matrix onpage 148 for compatibility.
PES Premium Small 07 70W10 100W13 100/150W
wired 10014 100/150W
wired 15015 150W17 175W25 250W1
DistributionBallastWattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type IIIFT Forward Throw,
Sharp Cutoff
Refer to optical matrixbelow for compatibility
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance(Lag) Normal
XH High Reactance(Lag) High
CA CWA (Auto Reg)
S HPSM MH
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347V
Paint(blank) Bronze (standard)
BK BlackWH White
Terminal Block(blank) Wire Nuts (standard)
TB Wired to L1 & N PositionsT2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L3
Position)
Listing(blank) UL Listed (standard)
CS CUL or CSA ListedXL No Listing
Photocontrol Receptacle(blank) Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle
Options
Starter(blank) Open Board (standard)
EC Encapsulated Plug-inOP Open Board Plug-in
LampLC Lamp Included, Clear
FusingSF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480V)
Misc.PC Photocontrol Included per
Voltage SpecifiedTL Tool-less Entry5H 50 Hertz Ballast FrequencySH Shorting CapNL NEMA Label
(blank) Less Bracket for Mast Arm Mount
SP4 Square, 4” (standard)SP9 Square, 9”RP4 Round, 4”RP9 Round, 9”
WW4 Wood, 4”WW9 Wood, 9”
Mounting
PESArea Lighting
70-150W HPS, 100-250W MH
Available Summer 2008
Shipped SeparateRKPES EF BZ External Mast
Arm Mount
Optic Distribution
R2 R3 FT07S � � �
10S � � �
10M � � �
15S � � �
15M � � �
17M � � �
25M � � �
Notes:
1 MA only
P R O D U C T O V E R V I E W
126 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Applications:Parking lotsRoadwaysCommercial environmentsOffice communities
Features:Rugged, heavy-gauge, premium extruded aluminum housing
Square shape, seam-welded and internally sealed for weathertight integrity
Standard finish is dark bronze corrosion resistant polyester powder
Anodized, segmented reflectors for uniformity and control
Reflectors are tool-less, rotatable and interchangeable
4 cutoff distributions available, R2, R3, R5 and FT
Natural anodized, extruded aluminum door frame sealed to housing by siliconeclosed-cell gasket. Can be hinged from any of the four sides
Lens is .125” thick, impact-resistant tempered glass
Rugged die-cast aluminum enclosure, polyester powder coat paint finish
Extruded 4” aluminum arm for square pole mounting is standard, optionalmountings available
Constant wattage autotransformer for 250W and above. Removable powertray and positive-locking disconnect plug
Mogul-base porcelain socket with copper alloy, nickel-plated screw shell andcenter contact
Tool-less PEC receptacle, standard
Terminal block and phosphor bronze PEC receptacle contacts, standard
UL Listed 1500W-600V. 4KV pulse rated
UL Listed, standard. CSA Certified or NOM Certified. UL Listed for wetlocations
Effective Projected Area (EPA)The EPA for the PEM is 1.9 sq. ft.Approx. Wt = 39.9 lbs.
PEMArea Lighting200-400W HPS, 250-400W MH
NEW
Available Summer 2008
PREFERRED SELECTION CATALOG NUMBERS
PEM 40M SC MT1 R5 SP9 LC PCPEM 40M SC MT1 FT SP9 LC PC
127Product Guide
O R D E R I N G I N F O R M A T I O N
Example: P E M 4 0 M C A M T 1 R 3 S P 4 L C P C
PEMArea Lighting
200-400W HPS, 250-400W MH
Refer to the ballast matrix onpage 149 for compatibility.
PEM PremiumMedium
20 200W25 250W31 310W32 320W35 350W40 400W
DistributionBallastWattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type IIIR5 Type V, SquareFT Forward Throw,
Sharp Cutoff
Refer to optical matrixbelow for compatibility
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance(Lag) Normal
XH High Reactance(Lag) High
CA CWA (Auto Reg)SC SCWA
S HPSM MH
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347V
Paint(blank) Bronze (standard)
BK BlackWH White
Terminal Block(blank) Wire Nuts (standard)
TB Wired to L1 & N PositionsT2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L3
Position)
Listing(blank) UL Listed (standard)
CS CUL or CSA ListedXL No Listing
Photocontrol Receptacle(blank) Photocontrol Receptacle
(standard)NR No Photocontrol Receptacle
Options
Starter(blank) Open Board (standard)
EC Encapsulated Plug-inOP Open Board Plug-in
LampLC Lamp Included, Clear
FusingSF Single Fuse (120, 277, 347V)DF Double Fuse (208, 240, 480V)
Misc.PC Photocontrol Included per
Voltage SpecifiedTL Tool-less Entry5H 50 Hertz Ballast FrequencySH Shorting Cap
(blank) Less Bracket for Mast Arm Mount
SP4 Square, 4”SP9 Square, 9”RP4 Round, 4”RP9 Round, 9”
WW4 Wood, 4”WW9 Wood, 9”
Mounting
Shipped SeparateRKPEM EF BZ External Mast
Arm Mount
Available Summer 2008
Optic Distribution
R2 R3 R5 FT20S � � � �
25S � � � �
25M � � � �
31S � � � �
32M � � � �
35M � � � �
40S � � � �
40M � � � �
P R O D U C T O V E R V I E W
128 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Applications:Parking lotsStreet lightingParking areas
Features:Heavy-gauge, spun aluminum housing
Integral structural support plate for mounting arm and electrical componentsensures rigidity and strength
Hinged aluminum door frame incorporates stainless steel hardware
Continuous silicone gasketing surrounds lens for weather-tight seal
Thermal, shock-resistant tempered flat or drop glass lens
Standard finish is dark bronze, electrostatically applied powder paint. Linearembossed accent reveals are standard. Additional architectural colors andstriping are available
Most flat lens configurations meet full-cutoff criteria. Vertical-lamp reflectorsare one-piece spun and formed anodized aluminum
High performance segmented aluminum reflectors are used with horizontallamps. They are rotatable and interchangeable
High reactance, high power factor for 50-150W. Constant wattageautotransformer for 175W. Metal halide 150W and below are standard withpulse-start ignitor technology; super SCWA pulse-start ballast required for200W
Porcelain, horizontally mounted medium base socket with copper alloy, nickel-plated screw shell and center contact
Arms are available for use with various poles, wall mounting and uniqueconfigurations. 4” aluminum fitter for open-top pole is available
Listed and labeled to UL standards for 25ºC ambient and wet locations. Listedand labeled to CSA standards. NOM Certified
11.55(293)
Effective Projected Area (EPA)The EPA for the VMR Arm Mount is 1.8 sq. ft., Approx. Wt = 35 lbs.The EPA for the VMR Post-top is 1.9 sq. ft.
VMRArea Lighting70-150W HPS, 50-200W MH
NEW
Available Summer 2008
PREFERRED SELECTION CATALOG NUMBERS
VMR 10M XH MT1 SM DG P9 LC PC TLVMR 10M XH MT1 SM FG P9 LC PC TLVMR 10S CA MT1 SM FG P9 LC PC TL
129Product Guide
O R D E R I N G I N F O R M A T I O N
Example: V M R 1 7 M C A 1 2 0 S M F G S 9 L C
VMR Vertical MediumRound
05 50W07 70W10 100W15 150W17 175W20 200W
Wattage / SourceSeries
S HPS1
M MH
VMRArea Lighting
70-150W HPS, 50-200W MH
Available Summer 2008
DistributionBallast
Vertical LampAM AsymmetricSM Symmetric
Horizontal LampR2 Area Type IIR3 Area Type IIIFT Forward Throw,
Sharp CutoffR5 Area Type V
Notes:
1 Not available with SCWA2 Pulse Start Metal Halide only 3 Standard arm-hole bolt spacing is 4-1/4”.
For 4-7/8” spacing, order “A4” option.4 Other colors available, please contact
your local American Electric Lightingrepresentative
5 Voids UL/CSA Listing, not available withMT, TT, and DT voltages
6 PC & SH not available with NR option7 HPS only, 400W max8 Limited availability, please contact
your local American Electric Lightingrepresentative
9 Nighttime FriendlyTM optic
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap Wired 480V
Paint4
(blank) Bronze (standard)BK BlackGY Gray
WH White
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)
Listing(blank) UL Listed (standard)
CS CSA Certified
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol Receptacle6
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Options
Starter7
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.A4 4-7/8” Hole Spacing on Housing
and ArmPC Photocontrol Included per
Voltage Specified6
TL Tool-less EntrySS Stainless Steel Fasteners (external)5H 50 Hertz Ballast Cycle8
NL NEMA Label on HousingSH Shorting Cap6
Accessories (shipped separately)VMREHS U Field Installable External HS Shield
Universal Tenon Adapter
Optics
FG Flat Glass ClearTempered9
DG Drop Glass ClearTempered
Refer to optical matrixbelow for compatibility
S9 Square Pole, 9” ArmP9 Round Pole, 9” ArmS2 Square Pole, 12” ArmP2 Round Pole, 12” Arm
WP Wood Pole or Wall, 12” ArmWB Wall Bracket, 12” Arm
EF External Mast Arm FitterP3 Round Pole Fitter, 2-3/8” ODP7 Round Pole Fitter, 2-7/8” ODS3 Square Pole Fitter, 2-3/8” ODS7 Square Pole Fitter, 2-7/8” OD
PT4 Spider Mount, 4” OD, OpenTop Pole
Mounting3
Optic Distribution
AM FG SM FG FT FG R2 FG R3 FG R5 FG AM DG SM DG FT DG R2DG R3DG07S � � � � � � � � � � �
10S � � � � � � � � � � �
10M � � � � � � � � � � �
15S � � � � � � � � � � �
15M � � � � � � � � � � �
17M � � � � � � � � � � �
20M � � � �
RN Reactor NormalPower Factor
RH Reactor High Power Factor
XN High Reactance /Lag NormalPower Factor
XH High Reactance /Lag HighPower Factor
CA CWASC SCWA2
CT CWI
Refer to the ballast matrix onpage 149 for compatibility.
P R O D U C T O V E R V I E W
130 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Applications:Parking lotsStreet lightingParking areas
Features:Heavy-gauge, spun aluminum housing
Integral structural support plate for mounting arm and electrical componentsensures rigidity and strength
Hinged aluminum door frame incorporates stainless steel hardware
Continuous silicone gasketing surrounds lens for weather-tight seal
Thermal, shock-resistant tempered flat or drop glass lens
Standard finish is dark bronze, electrostatically applied powder paint. Linearembossed accent reveals are standard. Additional architectural colors andstriping are available
Most flat lens configurations meet full-cutoff criteria. Vertical-lamp reflectorsare one-piece spun and formed anodized aluminum
High performance segmented aluminum reflectors are used with horizontallamps. They are rotatable and interchangeable
Mogul base porcelain socket with copper alloy, nickel-plated screw shell andcenter contact
Reflectors are rotatable and interchangeable
Arms are available for use with various pole and wall mounting. 4” aluminumfitter for open-top pole is available
Listed and labeled to UL standards for 25ºC ambient and wet locations. Listedand labeled to CSA standards. NOM Certified
Effective Projected Area (EPA)The EPA for the PSE is 1.3 sq. ft.Approx. Wt = 26.6 lbs.
VLRArea Lighting250-1000W HPS, 175-1000W MH
NEW
Available Summer 2008
PREFERRED SELECTION CATALOG NUMBERS
VLR X1M CA MT1 SM FG P2 LC TLVLR X1M CA MT1 SM DG P2 LC TLVLR X1M SC MT7 SM FG P2 LC TL
131Product Guide
O R D E R I N G I N F O R M A T I O N
Example: V L R 1 7 5 M C A 1 2 0 A M F G S 9 P C
VLRArea Lighting
250-1000W HPS, 175-1000W MH
Refer to the ballast matrix onpage 150 for compatibility.
VLR Vertical LargeRound
17 175W25 250W32 320W35 350W40 400WX1 1000W
Wattage / SourceSeries
S HPS1,11
M MH10
Available Summer 2008
DistributionBallast
Vertical LampAM AsymmetricSM SymmetricFV Forward Throw
Horizontal LampR2 Area Type IIR3 Area Type IIIFT Forward Throw,
Sharp Cutoff9
CA CWASC SCWA2
CT CWI
Notes:
1 Not available with SCWA2 Pulse Start Metal Halide only 3 Standard arm-hole bolt spacing is 4-1/4”.
For 4-7/8” spacing, order “A4” option.4 Other colors available, please contact
your local American Electric Lightingrepresentative
5 Voids UL/CSA Listing, not available withMT, TT, and DT voltages
6 PC & SH not available with NR option7 HPS only, 400W max8 Limited availability, please contact
your local American Electric Lightingrepresentative
9 Not available with PT4 option10 1000W MH uses reduced jacketed lamp11 1000W HPS uses reduced jacketed lamp
for FG options12 Nighttime FriendlyTM optic
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap wired 480V
Paint4
(blank) Bronze (standard)BK BlackGY Gray
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)
Listing(blank) UL Listed (standard)
CS CSA Certified
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol Receptacle6
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Options
Starter7
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.A4 4-7/8” Hole Spacing on Housing
and ArmPC Photocontrol Included per
Voltage Specified6
TL Tool-less EntrySS Stainless Steel Fasteners (external)5H 50 Hertz Ballast Cycle8
NL NEMA Label on HousingSH Shorting Cap6
Accessories (shipped separately)VLREHS U Field installable external HS shield
universal tenon adapter
Optics
FG Flat Glass ClearTempered12
DG Drop Glass ClearTempered
Refer to optical matrixbelow for compatibility
S9 Square Pole, 9” ArmP9 Round Pole, 9” ArmS2 Square Pole, 12” ArmP2 Round Pole, 12” Arm
WP Wood Pole or Wall, 12” ArmWB Wall Bracket, 12” Arm
EF External Mast Arm FitterP3 Round Pole Fitter, 2-3/8” ODP7 Round Pole Fitter, 2-7/8” ODS3 Square Pole Fitter, 2-3/8” ODS7 Square Pole Fitter, 2-7/8” OD
PT4 Spider Mount, 4” OD, OpenTop Pole
Mounting3
Optic Distribution
AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2FG R3FG FT DG25S � � � � � � � � � � � �
31S � � � � � � � � � � � �
40S � � � � � � � � � � � �
X1S � � - � � - - - - - - -17M � � � � � � � � � � � �
25M � � � � � � � � � � � �
32M � � � � � � - - - - - -35M � � � � � � - - - - - -40M � � � � � � � � � � � �
X1M � � - � � - - - - - - -
P R O D U C T O V E R V I E W
132 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Applications:Parking lotsRoadwaysCommercial environmentsOffice communities
Features:Separate compartments provide ease of installation (reduced weight ofhousing, short mounting bolts).
Rugged heavy gauge aluminum housing is continuously seam welded forweathertight integrity
Silicone gasket seals optical compartment from moisture, insects and dust
Available in multiple mounting options to fit a variety of applications
Choice of drop or flat lens to allow for full cutoff compliance
Separate optical and electrical compartments provide lower internaltemperatures extending fixture life
Available in a variety of IES light distributions patterns
1000W MH designed around reduced jacket lamp
Tool-less die-cast trigger latches
Choice of bolt spacing for mounting arm (4-1/4” or 4-7/8”)
Mogul base, E39, socket standard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPS
Ballast tray(s) installable or removable without tools (trigger latch and plug-inconnections)
AVL BIAArea Lighting – Ballast-in-Arm200-1000W HPS, 250-1000W MH
NEW
DIMENSIONS
AVL Flat Glass AVL Drop Glass AVL-Ballast-in-Arm
Effective Projected Area (EPA) Approximate WeightSingle 4.4 sq. ft. 99 lbs.2 @ 180 8.42 sq. ft. 170 lbs.2 @ 90 7.8 sq. ft. 170 lbs.3 @ 90 11.82 sq. ft. 241 lbs.4 @ 90 13.52 sq. ft. 312 lbs.
133Product Guide
O R D E R I N G I N F O R M A T I O N
Example: A V L B I A 1 X M C A M T 1 S M D G 4 9 0 3 0 F T
AVL BIAArea Lighting – Ballast-in-Arm
200-1000W HPS, 250-1000W MH
Refer to the ballast matrix onpage 150 for compatibility.
AVL BIA AVLBallast in Arm
AVL LMS AVL Low MastSystem
20 200W25 250W31 310W32 320W1
35 350W1
40 400W45 450W1
75 750W1X 1000W1
DistributionBallastWattage / SourceSeries
Vertical LampAM AsymmetricSM SymmetricFV Forward Throw3
Horizontal LampR2 Area Type IIR3 Area Type III
CA CWASC SCWA2
CT CWI
S HPSM MH
Notes:
1 Reduced jacket lamp only2 Pulse Start Metal Halide only 3 Available in drop glass only4 Other colors available, please contact
your local American Electric Lightingrepresentative
5 PC & SH not available with NR option6 Limited availability, please contact
your local American Electric Lightingrepresentative
7 Not required for LMS8 Nighttime FriendlyTM optic
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V
Paint4
(blank) Bronze (standard)BK BlackGY Gray
WH WhiteUP Unpainted
ListingUL UL ListingCS CSA Certified
MX NOM Listed
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol Receptacle6
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Options
Misc.PC Photocontrol Included per
Voltage SpecifiedSS Stainless Steel Fasteners (external)NL NEMA Label on HousingSH Shorting Cap6
4D 4” OD Tenon5H 50 Hertz Ballast Cycle6
Accessories (shipped separately)AVLEHS U Field Installable External
House Side Shield
Optics
FG Flat Glass ClearTempered8
DG Drop Glass ClearTempered
Refer to optical matrixbelow for compatibility
Units Degrees1 902 18034 *Number of Units and
Degrees should be combined to form onenumber. Ex: 490
20FT25FT30FT35FT40FT45FT50FT55FT60FT
Mounting7 Pre-Wire Length7
Optic Distribution
AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2DG R3DG FT DG25S � � � � � � � � � � � �
31S � � � � � � � � � � � �
40S � � � � � � � � � � � �
X1S - - - � � � - - - - - -25M � � � � � � � � � � � �
32M � � � � � � - - - - - -35M � � � � � � - - - - - -40M � � � � � � � � � � � �
1XM � � � � � � � � - � - -
P R O D U C T O V E R V I E W
134 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
Applications:Parking lotsRoadwaysCommercial environmentsOffice communities
Features:Rugged heavy gauge aluminum housing is continuously seam welded forweathertight integrity
Silicone gasket seals optical compartment from moisture, insects and dust
Available in multiple mounting options to fit a variety of applications
Choice of drop or flat lens to allow for full cutoff compliance
Available in a variety of IES light distributions patterns
1000W MH designed around reduced jacket lamp
Tool-less die-cast trigger latches
Choice of bolt spacing for mounting arm (4-1/4” or 4-7/8”)
Mogul base, E39, socket standard
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPS
AVLArea Lighting250-1000W HPS, 250-1000W MH
Effective Projected Area (EPA)The EPA for the AVL is 2.8 sq. ft.Approx. Wt = 53 lbs.
DIMENSIONS
AVL Flat Glass AVL Drop Glass
PREFERRED SELECTION CATALOG NUMBERS
AVL 1XM CA MT7 SM DG S9 TLAVL 1XM SC MT1 SM DG S9 NR LCAVL 1XM CA MT1 SM DG P2 NR LC TL
135Product Guide
Example: A V L 1 X M C A M T 7 S M D G S 9
O R D E R I N G I N F O R M A T I O N
Refer to the ballast matrix onpage 150 for compatibility.
AVL American VerticalLuminaire
25 250W31 310W32 320W1
35 350W1
40 400W45 450W1
75 750W1X 1000W1
DistributionBallastWattage / SourceSeries
Vertical LampAM AsymmetricSM SymmetricFV Forward Throw
Horizontal LampR2 Area Type IIR3 Area Type IIIFT Area Type IV
CA CWASC SCWA2
CT CWI
S HPSM MH
Notes:
1 Reduced jacket lamp only for MH2 Pulse Start Metal Halide only 3 Standard arm-hole bolt spacing is 4-1/4”.
For 4-7/8” spacing, order “A4” option.4 Other colors available, please contact
your local American Electric Lightingrepresentative
5 Voids UL/CSA Listing, not available withMT, TT, and DT voltages
6 PC & SH not available with NR option7 HPS only, 400W max8 Limited availability, please contact
your local American Electric Lightingrepresentative
9 Nighttime FriendlyTM optic10 See page 145 for options
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap wired 480V
Paint4
(blank) Bronze (standard)BK BlackGY Gray
WH WhiteUP Unpainted
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)
ListingUL UL ListingCS CSA Certified
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol Receptacle6
LampLC Lamp Included, ClearLD Lamp Included, Deluxe/Coated
Options
Starter7
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Misc.A4 4-7/8” Hole Spacing on Housing
and ArmPC Photocontrol Included per
Voltage Specified6
TL Tool-less EntrySS Stainless Steel Fasteners (external)5H 50 Hertz Ballast Cycle8
NL NEMA Label on HousingSH Shorting Cap6
TL Trigger Latch4D 4” OD Tenon
Accessories (shipped separately)AVLEHS U Field Installable External HS Shield
Universal Tenon Adapter10
Optics
FG Flat Glass ClearTempered9
DG Drop Glass ClearTempered
Refer to optical matrixbelow for compatibility
AVLArea Lighting
250-1000W HPS, 250-1000W MH
S9 Square Pole, 9” ArmP9 Round Pole, 9” ArmS2 Square Pole, 12” ArmP2 Round Pole, 12” Arm
WP Wood Pole or Wall, 12” ArmWB Wall Bracket, 12” Arm
EF External Mast Arm FitterP3 Round Pole Fitter, 2-3/8” ODP7 Round Pole Fitter, 2-7/8” ODS3 Square Pole Fitter, 2-3/8” ODS7 Square Pole Fitter, 2-7/8” OD
PT4 Spider Mount, 4” OD, OpenTop Pole
Mounting3
Optic Distribution
AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2DG R3DG FT DG25S � � � � � � � � � � � �
31S � � � � � � � � � � � �
40S � � � � � � � � � � � �
X1S - - - � � � - - - - - -25M � � � � � � � � � � � �
32M � � � � � � - - - - - -35M � � � � � � - - - - - -40M � � � � � � � � � � � �
1XM � � � � � � � � - � - -
P R O D U C T O V E R V I E W
136 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
DIMENSIONS
Applications:Parking lotsRoadwaysResidential communitiesCommercial environmentsOffice communities
Features:Durable die-cast aluminum housing for long-life performance
Optical assembly designed for maximum performance
Removable ballast tray electrical system for installation and maintenance ease
"Breathing Seal" developed by American Electric prevents contaminants fromentering optical assembly for maximum efficiency
Optics available in flat tempered glass, sag glass, drop acrylic and droppolycarbonate
Available in a variety of IES light distributions patterns and cutoffclassifications
Standard product is designed to mount to pipe mast arm. Direct pole mountarms are available
Arm ordered separate, see page 144
All electrical components warranted by American Electric Lighting's 6-yearguarantee
UL Listed
Mogul base, E39, socket standard
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15
LuxMaster® Series 53Area Lighting70-150W HPS, 175W MH
Effective Projected Area (EPA)The EPA for the LuxMaster® Series 53 withrefractor 1.4 sq. ft.Approx Wt = 30 lbs.
Effective Projected Area (EPA)The EPA for the LuxMaster® Series 53 with flatlens is 1.1 sq. ft.
PREFERRED SELECTION CATALOG NUMBERS
53 10S CA MT1 R2 DA53 15S CA MT1 R2 FG53 10S RH 120 R3 FG
137Product Guide
Example: 5 3 1 5 S C A M T 1 R 3 F G L C P C
O R D E R I N G I N F O R M A T I O N
Refer to the ballast matrix onpage 151 for compatibility.
53 LuxMasterShoebox
07 70W10 100W13 100/150W
wired 10014 100/150W
wired 15015 150W17 175W
DistributionBallastWattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type III
Refer to optical matrixbelow for compatibility
RN Reactor NormalPower Factor
RH Reactor High PowerFactor
XN High Reactance /Lag NormalPower Factor
XH High Reactance /Lag HighPower Factor
CA CWA Auto RegMR Mag Reg (3 coil)CT CWI
S HPSM MH
Notes:
1 Other colors available, please contact yourlocal American Electric Lighting representative
2 Voids UL/CSA Certified Options and notavailable in MT, TT, and DT voltages
3 PC, & SH not available with NR option4 HPS only5 Limited availability, please contact your local
American Electric Lighting representative6 Nighttime FriendlyTM optic
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240 Wired 240VDT4 Dual Tap 240/480 Wired 480V
Mounting(blank) Internal fitter (1-1/4”)
M2 Internal fitter (pre-set 2”)
Paint1
(blank) Bronze (standard)BK BlackGY Gray
WH White
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)
Fusing2
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol Receptacle3
LampLC Lamp Included, ClearLD Lamp Included, Deluxe
Options
Starter4
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-inPS Protected/Auto Shutoff5
Listing(blank) UL Listed (standard)
CS CSA Certified
Misc.PC Photocontrol Included per
Voltage Specified3
SS Stainless Steel Fasteners (external)LA Lightning Arrestor (Void UL/CSA
Listed Options)5H 50 Hertz Ballast Cycle5
NL NEMA Label on HousingSH Shorting Cap3
HK Hinge Keeper
Optics
DA Drop AcrylicPrismatic Refractor
DP Drop PolycarbonatePrismatic Refractor
FG Flat Glass ClearTempered6
SG Sag Glass Refractor
LuxMaster® Series 53Area Lighting
70-150W HPS, 175W MH
Optic Distribution
R2 DA R3 DA R2 DP R3 DP R2 FG R3 FG R2 SG R3 SG05S � � � � � � � �
07S � � � � � � � �
10S � � � � � � � �
15S � � � � � � � �
17M - - - - � � � �
P R O D U C T O V E R V I E W
138 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
DIMENSIONS
Features:Die-cast aluminum housing for long-life performance
Optical assembly designed for maximum performance
Ballast tray electrical system for installation and maintenance ease
"Breathing Seal" developed by American Electric preventing contaminantsfrom entering optical assembly
Optics available in flat tempered glass, sag glass, drop acrylic and droppolycarbonate
Available in a variety of IES light distributions patterns
Standard product is designed to mount to pipe mast arm. Direct pole mountarms are available
Arm ordered separate, see page 144
UL Listed
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Mogul base, 539 socket std.
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15
Applications:Parking lotsRoadwaysResidential communitiesCommercial environmentsOffice communities
LuxMaster® Luminaire Series 153Area Lighting200-400W HPS, 200-400W MH
Effective Projected Area (EPA)The EPA for the LuxMaster® HPS LuminaireSeries 153 with flat lens is 2.1 sq. ft.Approx Wt = 45 lbs.
The EPA for the LuxMaster® HPS LuminaireSeries 153 with drop lens is 2.4 sq. ft.
PREFERRED SELECTION CATALOG NUMBERS
153 40M SC MT1 R3 SG153 25S CA MT1 R3 FG153 40S CA MT1 R3 FG153-1-BZ
139Product Guide
Example: 1 5 3 2 5 S C A M T 1 R 3 F G L C E C P C
O R D E R I N G I N F O R M A T I O N
Refer to the ballast matrix onpage 151 for compatibility.
LuxMaster® Luminaire Series 153Area Lighting
200-400W HPS, 200-400W MH
153 LuxMasterShoebox
20 200W25 250W31 310W40 400W23 250/400W
wired 25024 250/400W
wired 400
DistributionBallastWattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type III
Refer to optical matrixbelow for compatibility
RN Reactor NormalPower Factor
RH Reactor High PowerFactor
XN High Reactance /Lag NormalPower Factor
XH High Reactance /Lag HighPower Factor
CA CWA Auto RegMR Mag Reg (3 coil)CT CWISC SCWA
S HPSM MH
Notes:
1 Other colors available, please contact yourlocal American Electric Lighting representative
2 Voids UL/CSA listing, not available with MT, TT,and DT voltages
3 PC, & SH not available with NR option4 HPS only5 Limited availability, please contact your local
American Electric Lighting representative6 Nighttime FriendlyTM optic
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240 Wired 240VDT4 Dual Tap 240/480 Wired 480V
Mounting(blank) Internal fitter (1-1/4”)
M2 Internal fitter (pre-set 2”)
Paint1
(blank) Bronze (standard)BK BlackGY Gray
WH White
Terminal Block(blank) Terminal Block (standard)
T2 Wired to L1 & L2 PositionsT3 3 Wire Operation (L1, N, L2
Position)
Fusing2
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol Receptacle3
LampLC Lamp Included, ClearLD Lamp Included, Deluxe
Options
Starter4
(blank) Open Board (standard)EC Encapsulated Plug-inOP Open Plug-in
Listing(blank) UL Listed (standard)
CS CSA Certified
Misc.PC Photocontrol Included per
Voltage Specified3
SS Stainless Steel Fasteners (external)LA Lightning Arrestor 5H 50 Hertz Ballast Cycle5
NL NEMA Label on HousingSH Shorting Cap3
HK Hinge Keeper
Optics
DA Drop AcrylicPrismatic Refractor
DP Drop PolycarbonatePrismatic Refractor
FG Flat Glass ClearTempered6
SG Sag GlassPrismatic Refractor
Optic Distribution
R2 DA R3 DA R2 DP R3 DP R2 FG R3 FG R2 SG R3 SG20S � � � � - � � �
25S � � � � - � � �
31S � � � � - � � �
40S � � � � - � � �
25M - - - - � - - �
40M - - - - � - - �
* Requires use of ED28 lamp
P R O D U C T O V E R V I E W
140 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
DIMENSIONS
Features:Rugged heavy gauge aluminum housing is continuously seam welded forweathertight integrity
Multiple mounting options to fit a variety of applications
Optical assembly designed for maximum performance
Removable ballast tray electrical system for installation and maintenance ease
Mogul base, E39 socket standard
"Breathing Seal" developed by American Electric prevents contaminants fromentering optical assembly for maximum efficiency
Tempered flat glass lens standard, drop polycarbonate option available
Available in a variety of IES full cutoff light distributions patterns
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPS
Applications:Parking lotsOffice complexesSecurity lightingResidential areasCommercial environments
LuxMaster® Classic Series LSArea Lighting70-150W HPS, 175W MH
Effective Projected Area (EPA)The EPA for the LuxMaster Classic Luminaire, Series LS is 1.75 sq. ft.Approx Wt. = 20 lbs.
141Product Guide
Example: L S 1 5 S R H 1 2 0 R 3
O R D E R I N G I N F O R M A T I O N
Refer to the ballast matrix onpage 152 for compatibility.
LS LuxMasterShoebox,Small
07 70W10 100W15 150W17 175W
DistributionBallastWattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type IIIR5 Roadway Type V
RN Reactor NormalPower Factor
RH Reactor High PowerFactor
XN High Reactance /Lag NormalPower Factor
XH High Reactance /Lag HighPower Factor
CA CWA Auto RegCT CWI
S HPSM MH
Notes:
1 Voids UL/CSA Certified Options andnot available in MT, TT, and DT voltages
2 PC, & SH not available withNR option
3 NL not available4 Other colors available, please
contact your local AmericanElectric Lighting representative
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap WWired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240 Wired 240V
Options
Fusing1
SF Single Fuse(120, 277, 347V)
DF Double Fuse(208, 220, 240, 480V)
LuxMaster® Classic Series LSArea Lighting
70-150W HPS, 175W MH
1) Ballast Tray
LS LuxMasterShoebox,Small
Distribution
Wattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type IIIR5 Roadway Type V
S HPSM MH
2) Housing Example: L S 1 5 S R 3 P C H S G
Housing
HSG Housing UnitPaint4
(blank) Bronze (standard)BK BlackGY Gray
WH White
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol
Receptacle2
Options
3) Mounting Example: L S P 3 B Z
LM LuxMasterShoebox,Small
Series Mounting
P Square Pole 12” ArmW Wall Bracket 12” ArmK Adjustable Knuckle
M External FitterY Yoke MountT Square Tenon1 Square Tenon 2 Arms 90°2 Square Tenon 2 Arms 180°
Paint
Paint4
BZ Bronze(standard)
BK BlackGY Gray
WH White
The following three separate components must be ordered:1) BALLAST TRAY 2) HOUSING 3) MOUNTING
Misc.SS Stainless Steel
Fasteners (external)SH Shorting Cap2
PC Photocontrol Included perVoltage Specified2
LC Lamp Included, Clear
O R D E R I N G I N F O R M A T I O N
O R D E R I N G I N F O R M A T I O N
3 Square Tenon 3 Arms 90°4 Square Tenon 4 Arms 90°5 Round Tenon6 Round Tenon 2 Arms 90°7 Round Tenon 2 Arms 180°8 Round Tenon 3 Arms 90°9 Round Tenon 3 Arms 120°R Round Tenon 4 Arms 90°
07 70W10 100W15 150W17 175W
XX No Ballast3
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)NR No Photocontrol
Receptacle2
Each Ships Separately
P R O D U C T O V E R V I E W
142 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
DIMENSIONS
Features:Rugged heavy gauge aluminum housing is continuously seam welded forweathertight integrity
Multiple mounting options to fit a variety of applications
Optical assembly designed for maximum performance
Removable ballast tray electrical system for installation and maintenance ease
Mogul base, E39 socket standard
"Breathing Seal" developed by American Electric prevents contaminants fromentering optical assembly for maximum efficiency
Tempered flat glass lens standard, drop polycarbonate option available
Available in a variety of IES full cutoff light distributions patterns
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Suitable for -30°C MH / -40°C HPSApplications:Office complexesParking lotsResidential areasCommercial environmentsSecurity lighting
LuxMaster® Classic Series LMArea Lighting200-400M HPS, 250-400W MH
Effective Projected Area (EPA)The EPA for the LuxMaster Classic Luminaire, Series LM is 2.36 sq. ft.Approx Wt. = 45 lbs.
143Product Guide
Example: L M 2 0 S X H 1 2 0 R 3
O R D E R I N G I N F O R M A T I O N
Refer to the ballast matrix onpage 152 for compatibility.
O R D E R I N G I N F O R M A T I O N
LM LuxMasterShoebox,Medium
20 200W25 250W40 400W
DistributionBallastWattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type IIIR5 Roadway Type V
RN Reactor NormalPower Factor
RH Reactor High PowerFactor
XN High Reactance /Lag NormalPower Factor
XH High Reactance /Lag HighPower Factor
CA CWA Auto RegCT CWISC SCWA
S HPSM MH
Notes:
1 Voids UL/CSA Certified options andnot available in MT, TT, and DT voltages
2 PC & SH not available withNR option
3 Other colors available, pleasecontact your local American ElectricLighting representative
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240 Wired 240V
Options
Fusing1
SF Single Fuse(120, 277, 347V)
DF Double Fuse(208, 220, 240, 480V)
Terminal Block(blank) Terminal Block
(standard)T2 Wired to L1 & L2
PositionsT3 3 Wire Operation
(L1, N, L2 Position)Photocontrol Receptacle
NR No PhotocontrolReceptacle2
1) Ballast Tray
Example: L M 2 0 S R 3 H S G
The following three separate components must be ordered:1) BALLAST TRAY 2) HOUSING 3) MOUNTING
LuxMaster® Classic Series LMArea Lighting
200-400M HPS, 250-400W MH
LM LuxMasterShoebox,Medium
20 200W25 250W31 310W40 400W
Distribution
Wattage / SourceSeries
R2 Roadway Type IIR3 Roadway Type IIIR5 Roadway Type V
S HPSM MH
2) Housing
Housing
HSG Housing UnitPaint3
(blank) Bronze (standard)BK BlackGY Gray
WH White
Photocontrol Receptacle(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle2
Options
Misc.PC Photocontrol Included per
Voltage Specified2
SS Stainless SteelFasteners (external)
SH Shorting Cap2
O R D E R I N G I N F O R M A T I O N
3) Mounting Example: L M P 3 B Z
LM LuxMasterShoebox,Medium
Series Mounting
P Square Pole 12” ArmW Wall Bracket 12” ArmK Adjustable Knuckle
M External FitterY Yoke MountT Square Tenon1 Square Tenon 2 Arms 90°2 Square Tenon 2 Arms 180°
Paint
Paint3
BZ Bronze(standard)
BK BlackGY Gray
WH White
O R D E R I N G I N F O R M A T I O N
3 Square Tenon 3 Arms 90°4 Square Tenon 4 Arms 90°5 Round Tenon6 Round Tenon 2 Arms 90°7 Round Tenon 2 Arms 180°8 Round Tenon 3 Arms 90°9 Round Tenon 3 Arms 120°R Round Tenon 4 Arms 90°
Each Ships Separately
144
O R D E R I N G D A T A
144 For more information please visit our website:www.americanelectriclighting.com
AccessoriesMounting Hardware
Product Guide
Area Rectilinear ArmField Installed
A B C D53-1-BZ1 2.031” 2.781” 3.25” 8” 32153-1-BZ1 2.031” 3.531” 4” 10” 46
NOTE: Pole must be drilled to match dimensions shown
Area Wall Mount Bracket
A B C D53-1-W-BZ1 5.687” 4.687” 2.781” 2.031” 32153-1-W-BZ1 5.687” 4.687” 3.531” 2.031” 46
NOTE: Pole must be drilled to match dimensions shown
Round Pole Mounting
53-1-BZ-WM1 Pole Mount Comes with Rectilinear Arm. Series 53 7153-1-BZ-WM1 Series 153 5
Polycarbonate Shield53-VS For flat lens only. 5
Mast Arm FItterRKASA-EF-BZ1 ASA External Mast Arm FItter Series ASA 5RKPEM-EF-BZ1 PEM External Mast Arm FItter Series PEM 5RKPES-EF-BZ1 PES External Mast Arm FItter Series PES 5
House-Side ShieldASA R2/3/5 HS ASA Internal for R2, R3, R5 Reflectors Series 53 5ASA R4 HS ASA Internal for R4 Reflectors Series 153 5PEM R2/R3 HS PEM Internal for R2, R3, R5 Reflectors Series PEMPES R2/R3 HS PES Internal for R2, R3, R5 Reflectors Series PESLS-HS-BZ LS External, Bronze Series LS 5LM-HS-BZ LM External, Bronze Series LM 5AVL-EHS-BZ AVL External, Bronze Series AVL 5
Catalog Item ApproxNumber Wt. (lbs)
2-1/2
CD
12-1/2"
Notes: 1 Standard finish is dark bronze. For other finishes change BZ to BK (black) or WH (white)
145Product Guide
A V A I L A B I L I T Y
AccessoriesMounting Hardware
Pole Top Tenon Adapters1
Drill Pattern 1@90º 2@90º 3@90º 4@90º 2@180º 3@120º
Mounting Pattern 2-3/8” OD Tenon
Standard 4-1/4” TMS-20-190 TMS-20-290 TMS-20-390 TMS-20-490 TMS-20-280 TMS-20-320
Optional 4-7/8” – – – T47-20-490 – –
Mounting Pattern 2-7/8” OD Tenon
Standard 4-1/4” TMS-25-190 TMS-25-290 TMS-25-390 TMS-25-490 TMS-25-280 TMS-25-320
Optional 4-7/8” – – – T47-25-490 – –
NOTES:1 For R2 and R3 optics only
Standard finish is dark bronze, contact American Electric Lighting for other finishes
NOTES:1 For use with AVL and ASA only
53 153 AVL LS LM ASARectilinear Arm, Dark Bronze 53-1-BZ 153-1-BZ – – – –Wall Mount Bracket, Dark Bronze 53-1-W-BZ 153-1-W-BZ – – – –Round Pole Mounting, Dark Bronze 53-1-BZ-WM 153-1-BZ-WM – – – –Single-Arm Steel Bracket, Dark Bronze 9401-H 9401-H – – – –Single-Arm Steel Bracket, Galvanized 9401-G 9401-G – – – –House-Side Shield, Dark Bronze RK53-HS-SHLD RK153-HS-SHLD AVL EHS BZ LS-HS LM-HS-BZ –4-1/4” Pole Top Tenon Adapter, Dark Bronze – – See chart below – – See chart below4-7/8” Pole Top Tenon Adapter, Dark Bronze – – See chart below – – See chart below
PES PEM VMR VLRRectilinear Arm, Dark Bronze – – – –Wall Mount Bracket, Dark Bronze – – – –Round Pole Mounting, Dark Bronze – – – –Single-Arm Steel Bracket, Dark Bronze – – – –Single-Arm Steel Bracket, Galvanized – – – –House-Side Shield, Dark Bronze PES-HS-BZ1 PEM-HS-BZ1 VMR-EHS-BZ1 VLR-EHS-BZ1
4-1/4” Pole Top Tenon Adapter, Dark Bronze See chart below See chart below See chart below See chart below4-7/8” Pole Top Tenon Adapter, Dark Bronze See chart below See chart below See chart below See chart below
146 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
M O U N T I N G O P T I O N S
AccessoriesSteel Bracket - Prime Coated(For Horizontally Mounted Luminaires)
EffectiveCatalog Projected Approx.Number Item Area (Sq. Ft.) Wt. (Lbs.)
9401 FABRICATED STEEL BRACKET — SINGLE ARM .4 10For mounting on 2'' (23/8'' OD) standard pipe or poletop tenon. 12'' spread.
See Isotach Wind Map, page 189
Note: Above brackets available with Galvanized Finish. To order add -G suffix to catalog number.
M O U N T I N G O P T I O N S
Square/round Tenon Adapter mountson top of round or square pole forluminaire attachment. Makes a smooth transition from pole toluminaire. Available mountingarrangements listed below.
Catalog Number - LM5BZ
Wraparound Yoke - Luminaire issuspended above mounting surface bymount and extends above poles.
Catalog Constructable Option
Mast Arm Mount - Luminaire isattached to curved mast arm formounting to pole or structure.
Catalog Number - LMMBZ
Pole Mount, secured with solid steelplate, attaches luminaire directly tosquare pole. Full length mounting screwssecure luminaire, arm and pole.
Catalog Number - LMPBZ
Wall Mount Arm secures luminaire towall plate with full length mount screws.Full length mounting screws secureluminaire to arm and wall plate.
Catalog Number - LMWBZ
Adjustable Knuckle for pole attachmentof luminaire. Makes a smooth transitionfrom pole to luminaire.
Catalog Number - LMKBZ
Catalog Number - LMGBZ
Accessories
Catalog Number Description
LMTBZ Square Tenon with 1 ArmLM1BZ Square Tenon with 2 Arms at 90°LM2BZ Square Tenon with 2 Arms at 180°LM3BZ Square Tenon with 3 ArmsLM4BZ Square Tenon with 4 ArmsLM5BZ Round Tenon with 1 ArmLM6BZ Round Tenon with 2 Arms at 90°LM7BZ Round Tenon with 2 Arms at 180°LM8BZ Round Tenon with 3 Arms at 90°LM9BZ Round Tenon with 3 Arms at 120°LM0BZ Round Tenon with 4 Arms at 90°
147Product Guide
M O U N T I N G O P T I O N S
B A L L A S T M A T R I C E S
148 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
ASA
PES
Watts 120 208 240 277 347 480 DT2 MT1 MT207S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN07M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN XH,XN XH,XN10S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN10M CA,XH,XN XH,XN XH,XN CA,XH,XN XH,XN - XH,XN XH,XN XH,XN13S RH,RN - - - - - - - -14S RH,RN - - - - - - - -15S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN - CA,XH,XN - CA,CT,XH,XN CA,CT,XH,XN15M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN XH,XN XH,XN17M CA CA CA CA CA CA CA CA CA20S CA CA CA,RH,RN CA - CA CA CA CA23S CA CA CA CA - - CA CA CA25S CA,XH,XN CA CA,XH,XN CA CA CA CA,XH,XN CA CA23M CA CA CA CA - - CA CA CA25M CA,SC CA,SC CA,SC CA,SC CA,CT,SC CA,SC CA,CT,SC CA,SC CA,SC31S CA CA CA CA - CA CA CA CA40S CA,CT CA,CT CA,CT CA,CT CA CA CA,CT - -40M CA,CT,SC CA,SC CA,CT,SC CA,SC - CA,SC CA,CT CA,SC CA,SC
Watts 120 208 240 277 347 480 DT2 MT1 MT207S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN07M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN XH,XN XH,XN10S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN10M CA,XH,XN XH,XN XH,XN CA,XH,XN XH,XN - XH,XN XH,XN XH,XN13S RH,RN - - - - - - - -14S RH,RN - - - - - - - -15S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN - CA,XH,XN - CA,CT,XH,XN CA,CT,XH,XN15M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN XH,XN XH,XN17M CA CA CA CA CA CA CA CA CA20M SC SC SC SC SC SC SC SC SC25M CA CA CA CA CA CA CA CA CA
Watts MT7 TT3 5T407S CA,CT,XH,XN CT,XH,XN -07M XH,XN XH,XN -10S CA,CT,XH,XN CT,XH,XN -10M XH,XN XH,XN -13S - - -14S - - -15S CA,CT,XH,XN CA,CT,XH,XN -15M XH,XN XH,XN -17M CA CA -20S CA CA -23S CA - -25S CA CA,CT CA23M CA - -25M CA,SC CA,CT CA31S CA - -40S - - CA40M CA,SC - CA
ASA continued
Watts MT7 TT3 5T407S CA,CT,XH,XN CT,XH,XN -07M XH,XN XH,XN -10S CA,CT,XH,XN CT,XH,XN -10M XH,XN XH,XN -13S - - -14S - - -15S CA,CT,XH,XN CA,CT,XH,XN -15M XH,XN XH,XN -17M CA CA -20M SC SC -25M CA CA -
PES continued
Area Lighting
149Product Guide
B A L L A S T M A T R I C E S
VMRWatts 120 208 240 277 347 480 DT2 MT1 MT207S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN10S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN10M CA,XH,XN XH,XN XH,XN CA,XH,XN XH,XN - XH,XN XH,XN XH,XN13S RH,RN - - - - - - - -14S RH,RN - - - - - - - -15S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN - CA,XH,XN - CA,CT,XH,XN CA,CT,XH,XN15M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN XH,XN XH,XN17M CA CA CA CA CA CA CA CA CA20M SC SC SC SC SC SC SC SC SC
Watts MT7 TT3 5T407S CA,CT,XH,XN CT,XH,XN -10S CA,CT,XH,XN CT,XH,XN -10M XH,XN XH,XN -13S - - -14S - - -15S CA,CT,XH,XN - -15M XH,XN XH,XN -17M CA CA -20M SC SC -
VMR continued
Area Lighting
PEMWatts 120 208 240 277 347 480 DT2 MT1 MT220S CA CA CA,RH,RN CA - CA CA CA CA23S CA CA CA CA - - CA CA CA25S CA,XH,XN CA CA,XH,XN CA CA CA CA,XH,XN CA CA23M CA CA CA CA - - CA CA CA25M CA,SC CA,SC CA,SC CA,SC CA,CT,SC CA,SC CA,CT,SC CA,SC CA,SC31S CA CA CA CA - CA CA CA CA32M SC SC SC SC SC SC - SC SC35M SC SC SC SC SC SC - SC SC40S CA,CT CA,CT CA,CT CA,CT CA CA CA,CT - -40M CA,CT,SC CA,SC CA,CT,SC CA,SC - CA,SC CA,CT CA,SC CA,SC
Watts MT7 TT3 5T420S CA CA -23S CA - -25S CA CA,CT CA23M CA - -25M CA,SC CA,CT CA31S CA - -32M SC SC -35M SC SC -40S - - CA40M CA,SC - CA
PEM continued
150 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
B A L L A S T M A T R I C E S
Area Lighting
VLRWatts 120 208 240 277 347 480 DT2 MT1 MT223S CA CA CA CA - - CA CA CA23M CA CA CA CA - - CA CA CA25S CA,XH,XN CA CA,XH,XN CA CA CA CA,XH,XN CA CA25M CA,SC CA,SC CA,SC CA,SC CA,CT,SC CA,SC CA,CT,SC CA,SC CA,SC31S CA CA CA CA - CA CA CA CA40S CA,CT CA,CT CA,CT CA,CT CA CA CA,CT - -40M CA,CT,SC CA,SC CA,CT,SC CA,SC - CA,SC CA,CT CA,SC CA,SC45M CA,CT,SC CA,SC CA,CT,SC CA,CT,SC - CA,SC CA,CT,SC CA,CT,SC CA,CT,SC75M CA CA CA CA CA CA CA CA CAX1S CA CA CA CA - - CA CA CAX1M CA,SC CA,SC SC CA,SC CA CA CA,SC CA,SC CA,SC
VLR continuedWatts MT7 TT3 5T423S CA - -23M CA - -25S CA CA,CT CA25M CA,SC CA,CT CA31S CA - -40S - - CA40M CA,SC - CA45M CA,CT,SC - CA75M CA - -X1S CA - -X1M CA,SC CA CA
AVL and AVL BIAWatts 120 208 240 277 347 480 DT2 DT425S CA CA CA CA CA CA CA, CT -25M CA,SC CA,SC CA,SC CA,SC SC CA SC -31S CA CA CA CA - CA CA -32M SC SC SC SC SC SC SC -35M SC SC SC SC SC SC SC -40S CA CA CA CA CA,CT CA CA -40M CA,SC CA,SC CA,SC CA,SC CA,CT,SC CA,SC CA,SC CT45M SC SC SC SC SC SC SC -75M SC SC - SC SC SC - -1XS CA CA,CT - CA CA CA CA -1XM CA,SC CA,SC SC CA,CT,SC CA,CT SC CA -
AVL and AVL BIA continuedWatts MT1 MT2 MT7 TT725S CA CA CA CA25M CA,SC CA,SC CA,SC SC31S CA CA CA -32M SC SC SC SC35M SC SC SC SC40S CA CA CA CA,CT40M CA,SC CA,SC CA,SC CA,SC,CT45M SC SC SC SC75M - - - -1XS CA CA CA CA1XM CA,SC CA,SC CA, SC CA
151Product Guide
B A L L A S T M A T R I C E S
LuxMaster® Series 53
LuxMaster® Series 153
LuxMaster® Series 53 continued
Watts 120 208 240 277 347 480 DT220S CA CA CA,RH,RN CA - CA CA23S CA CA CA CA - - CA23M CA CA CA CA - - CA25S CA,XH,XN CA CA,XH,XN CA CA CA CA,XH,XN25M CA,SC CA,SC CA,SC CA,SC CA,CT,SC MR CA,CT,SC31S CA CA CA CA - CA CA40S CA,CT CA,CT CA,CT CA,CT CA CA CA,CT40M CA,CT,SC CA,SC CA,CT,SC CA,SC - CA,SC CA,CT
Watts MT1 MT2 MT7 TT320S CA CA CA CA23S CA CA CA -23M CA CA CA -25S CA CA CA CA,CT25M CA,SC CA,SC CA,SC CA,CT31S CA CA CA -40S - - - -40M CA,SC CA,SC CA,SC -
LuxMaster® Series 153 continued
Area Lighting
Watts 120 208 240 277 347 480 DT207S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN XH,XN CA,CT,XH,XN07M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN10S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN CA,XH,XN CA,CT,XH,XN10M CA,XH,XN XH,XN XH,XN CA,XH,XN XH,XN - XH,XN13S RH,RN - - - - - -14S RN,RH - - - - - -15S CA,CT,RN,RH CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN - CA,XH,XN -15M XH,XN XH,XN XH,XN XH,XN XH,XN - XHX,XN17M CA CA CA CA CA CA CA
Watts MT1 MT2 MT7 TT307S CA,CT,XN,XH CA,CT,XN,XH CA,CT,XN,XH CT,XN,XH07M XN,XH XH,XN XN,XH XN,XH10S CA,CT,XN,XH CA,CT,XH.XN CA,CT,XN,XH CT,XN,XH10M XH,XN XH,XN XH,XN XH,X13S - - - -14S - - - -15S CA,CT,XH,XN CA,CT,XH.XN CA,CT,XH.XN -15M XH,XN XH,XN XH,XN XH,XN17M CA CA CA CA
152 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
B A L L A S T M A T R I C E S
Area Lighting
LuxMaster® Classic Series LM
LuxMaster® Classic Series LM continued
LuxMaster® Classic Series LS
LuxMaster® Classic Series LS continued
Watts 120 208 240 277 347 480 DT2 MT1 MT207S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN07M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN XH,XN XH,XN10S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN10M CA,XH,XN XH,XN XH,XN CA,XH,XN XH,XN - XH,XN XH,XN XH,XN13S RH,RN - - - - - - - -14S RH,RN - - - - - - - -15S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN - CA,XH,XN - CA,CT,XH,XN CA,CT,XH,XN15M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN XH,XN XH,XN17M CA CA CA CA CA CA CA CA CA20S CA CA CA,RH,RN CA - CA CA CA CA23S CA CA CA CA - - CA CA CA25S CA,XH,XN CA CA,XH,XN CA CA,CT CA CA,XH,XN CA CA23M CA CA CA CA - - CA CA CA25M CA,SC CA,SC CA,SC CA,SC CA,CT,SC CA,SC CA,CT,SC CA,SC CA,SC31S CA CA CA CA - CA CA CA CA40S CA,CT CA,CT CA,CT CA,CT CA CA CA,CT - -40M CA,CT,SC CA,SC CA,CT,SC CA,SC - CA,SC CA,CT CA,SC CA,SC
Watts MT7 TT3 5T407S CA,CT,XH,XN CT,XH,XN -07M XH,XN XH,XN -10S CA,CT,XH,XN CT,XH,XN -10M XH,XN XH,XN -13S - - -14S - - -15S CA,CT,XH,XN CA,CT,XH,XN -15M XH,XN XH,XN -17M CA CA -20S CA CA -23S CA - -25S CA CA,CT CA23M CA - -25M CA,SC CA,CT CA31S CA - -40S - - CA40M CA,SC - CA
Watts 120 208 240 277 347 480 DT203S RN - - - - - -05S RH,RN - - - - - -07S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN XH,XN CA,CT,XH,XN07M XH,XN XH,XN XH,XN XH,XN XH,XN - XH,XN10S CA,CT,RH,RN CA,CT,XN,XH CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN CA,XH,XN CA,CT,XH,XN10M CA,XH,XN XH,XN XH,XN CA,XH,XN XH,XN - XH,XN13S RH,RN - - - - - -14S RH,RN - - - - - -15S CA,CT,RH,RN CA,CT,XN,XH CA,CT,XH,XN CA,CT,XH,XN - CA,XH,XN -15M XH,XN XN,XH XH,XN XH,XN XH,XN - XH,XN17M CA CA CA CA CA CA CA
Watts MT1 MT2 MT7 TT303S - - - -05S - - - -07S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN07M XH,XN XH,XN XH,XN XH,XN10S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XN,XH CT,XH,XN10M XH,XN XH,XN XH,XN XH,XN13S - - - -14S - - - -15S CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN -15M XH,XN XH,XN XH,XN XH,XN17M CA CA CA CA
ACP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154
UltraFlood™ Series 75 . . . . . . . . . . . . . . . . . . . .156
UltraFlood™ Series 77 . . . . . . . . . . . . . . . . . . . . .158
Energy Saver Series CES . . . . . . . . . . . . . . . . . .160
Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . .162
Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . .163
AmeriSport™ Series ASP . . . . . . . . . . . . . . . . .164
Sportslighting Series SPF . . . . . . . . . . . . . . . . .166
Options & Accessories . . . . . . . . . . . . . . . . . . . .168
Ballast Matrices . . . . . . . . . . . . . . . . . . . . . .173-174
American Electric Lighting®
FLOODLIGHTING
153
P R O D U C T O V E R V I E W
154 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
ACP SeriesAmerican Compact Floodlight70-400W HPS; 175-400W MH
DIMENSIONS
Features:NEMA beam patterns available in a variety of options
Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Door is hinged and easily removable for quick maintenance
Fully pivoting painted wraparound yoke is standard, tenon and galvanized yokemounting options are available for precise aiming
UL listing is standard @ 40º ambient
For easy maintenance, tool-less entry is available
Standardized hardware for single-tool internal maintenance
Suitable for -40°C to 40°C HPS / -30ºC to 40ºC MH
Lens is thermal shock and impact resistant tempered flat glass
Approved for use in 1.5 G vibration applications
All electrical components warranted by American Electric Lighting's 6-yearguarantee
Effective Projected Area (EPA)The EPA for the ACP Series is 1.60 sq. ft.Approx. Wt. = 35 lbs.
Applications:Auto dealershipsSchoolsConstruction sitesRecreational areasChurches
Industrial sitesShopping centersParking lotsSubstationsBuilding facades
NEW
PREFERRED SELECTION CATALOG NUMBERS
ACP 15S RN 120 76 EC NL TLACP 23S CA MT1 76 EC 0643 TL NLACP 40M SC MT7 76 TM TLACP 40M SC MT1 76 LC 0443 TL PCACP 40M SC MT1 76 0443 TL NLACP 40S CA MT1 76 EC LC 0443 TL PC
155Product Guide
O R D E R I N G I N F O R M A T I O N
Example: A C P 4 0 M C A M T 1 7 6 0 4 4 3 L C T L P C
ACP SeriesAmerican Compact Floodlight
70-400W HPS; 175-400W MH
ACP AmericanCompactFlood
55 5H x 5V1
66 6H x 6V76 7H x 6V
RN Reactor Normal Power Factor4
RH Reactor HighPower Factor4
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWA (Auto Reg)CT CWI
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120V MT2 Multi-tap Wired 240V MT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347V5T4 5-tap Wired 480V
07 70W10 100W15 150W17 175W1
20 200W2
25 250W31 310W2
40 400W23 250/400W
Wired 250W3
24 250/400WWired 400W2, 3
S HPSM MH
Mounting5
(blank) Wraparound Yoke Mount (standard)1
YG Wraparound Yoke GalvanizedTM Tenon Slipfitter
Paint6
(blank) Bronze (standard)BK BlackGY Gray
WH White
Terminal Block(blank) Terminal Block Factory Wire
T2 Wired to L1 and L2 PositionT3 3 Wire Operation
(L1, N, L2 Position)
Listing(blank) UL Listed (standard)
CS CSA CertifiedXL No Listing
Photocontrol Receptacle(blank) Photocontrol Receptacle (standard)
NR No PEC Receptacle
Starter2
(blank) Open Board (standard)OP Open Board Plug-inEC Encapsulated Plug-in
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe
Fusing7
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Cord Length* Cord Type*
04 4’ 63 16-305 5’ 44 14-48
06 6’ 43 14-308 8’ 23 12-310 10’12 12’15 15’20 20’25 25’30 30’
Misc.TL Tool-less EntryPC Photocontrol Included per
Voltage Specified5H 50 Hertz Ballast Frequency9
NL NEMA Label
Notes:1 MH only2 HPS only3 Available in CA ballast option only4 Available in 120V for 50-150W HPS, 220 to 240V only
available for 200-400W HPS; not available in MH5 Painted to match fixture6 Other colors available, please contact your local
American Electric Lighting representative7 Not available in multi-tap ballast options8 For 3-wire operation and ground9 Limited availability, please contact your local American
Electric Lighting representative
NEMA Beam PatternBallast VoltageWattage / SourceSeries
*Cord length and typeshould be combined toform one number.Ex: 0423
Refer to the ballast matrix onpage 173 for compatibility.
P R O D U C T O V E R V I E W
156 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Features:NEMA beam patterns available in a variety of options including horizontaland vertical lamps
Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Door is hinged and easily removable for quick maintenance
Fully pivoting painted yoke is standard, tenon and galvanized yoke mountingoptions are available for precise aiming
UL listing is standard
For easy of maintenance, tool-less entry and ballast tray are available options
Lens is thermal shock and impact resistant tempered glass
Hydroformed reflector
Suitable for -30°C MH / -40°C HPS
All electrical components warranted by American Electric Lighting's 6-yearguarantee
UltraFlood™ Series 75Heavy Duty Floodlight100-400W HPS; 175-400W MH
Effective Projected Area (EPA)The EPA for the UltraFlood™ Series 75 is 2.75 sq. ft.Approx. Wt. = 37 lbs.
Applications:Auto dealershipsSchoolsConstruction sitesRecreational areasStorage yardsOffice BuildingsAirports
ChurchesIndustrial sitesShopping centersParking lotsSubstationsBuilding facades
DIMENSIONS
PREFERRED SELECTION CATALOG NUMBERS
75 40M SC MT1 66 0443 TL NL75 40S CA MT1 76 EC 0443 TL NL75 40S CA MT1 76 TM EC TL NL75 40M SC MT1 76 TM TL NL75 25S CA MT1 76 EC 0443 TL NL75 25S CA MT1 76 TM EC TL NL
Yoke Mount
Vertical Tenon Mount
157Product Guide
Example: 7 5 4 0 M C A M T 1 6 6 0 6 4 3 L C T L P C
O R D E R I N G I N F O R M A T I O N
UltraFlood™ Series 75Heavy Duty Floodlight
100-400W HPS; 175-400W MH
75 UltraFlood Vertical Lamp76 7H x 6V66 6H x 6V
Horizontal LampH6 6H x 6V
Refer to OpticDistribution Matrixbelow for compatibility.
RN Reactor Normal Power Factor
RH Reactor HighPower Factor
XN High Reactance (Lag) NormalPower Factor
XH High Reactance (Lag) HighPower Factor
CA CWA (Auto Reg)CT CWISC SCWA
MR Mag Reg (3 Coil)
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120V MT2 Multi-tap Wired 240V MT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
Wired 240VDT4 Dual Tap 240/480
Wired 480V5T4 5-tap Wired 480V
10 100W15 150W17 175W20 200W25 250W31 310W40 400W23 250/400W
Wired 250W24 250/400W
Wired 400W
S HPSM MH
Mounting(blank) Yoke Mount (standard)1
YG Wraparound Yoke GalvanizedTM Tenon Slipfitter1
Paint2
(blank) Bronze (standard)BK BlackGY Gray
WH White
Terminal Block3
(blank) Hard wired (standard)TB Terminal Block Factory WireT2 Wired to L1 and L2 PositionT3 3 Wire Operation
(L1, N, L2 Position)10
Listing(blank) UL Listed (standard)
CS CSA CertifiedXL No Listing
Photocontrol Receptacle(blank) Photocontrol Receptacle (standard)
NR No Photocontrol Receptacle4
Starter5
(blank) Open Board (standard)EC Encapsulated plug-inOP Open board plug-in
Options
LampLC Lamp Included, ClearLD Lamp Included, Deluxe
Fusing6
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Cord Length* Cord Type*
04 4’ 63 16-305 5’ 44 14-47
06 6’ 43 14-308 8’ 23 12-310 10’12 12’15 15’20 20’25 25’30 30’
Misc.TL Tool-less EntryPC Photocontrol Included per
Voltage Specified4
BT Removable BallastSS Stainless Steel fastener (external)5H 50 Hertz Ballast Frequency8
NL NEMA LabelPGS Ballistic Shield9
SH Shorting Cap4
Notes:1 Painted to match fixture2 Other colors available, please contact your local
American Electric Lighting representative3 Voids UL and CSA Listing4 PC, and SH not available with NR option5 HPS only6 Voids UL and CSA listing, not available in MT, TT, and DT
voltages7 For 3-wire operation and ground8 Limited availability, please contact your local
American Electric Lighting representative9 Ships separately
10 Not available in 120V
NEMA Beam PatternBallast VoltageWattage / SourceSeries
*Cord length and type should be combined to form one number. Ex: 0423
76 66 H610S � - �
15S � - �
20S � - �
25S � - �
40S � - �
17M � � �
25M � � �
40M � � �
Optic Distribution
Refer to the ballast matrix onpage 173 for compatibility.
P R O D U C T O V E R V I E W
158 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:NEMA beam patterns available in a variety of options with horizontal lamp
Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance
Door is hinged and easily removable for quick maintenance
Fully pivoting painted yoke is standard, tenon and galvanized yoke mountingoptions are available for precise aiming
UL listing is standard
For easy maintenance, tool-less entry is available
Suitable for -30°C MH / -40°C HPS
Lens is thermal shock and impact resistant tempered glass
All electrical components warranted by American Electric Lighting's 6-yearguarantee
UltraFlood™ Series 77Heavy Duty Floodlight400-1000W HPS; 400-1000W MH
Effective Projected Area (EPA)The EPA for the UltraFlood™ Series 77 is 3.97 sq. ft.Approx. Wt. = 65 lbs.
Applications:Auto dealershipsSchoolsChurchesIndustrial sites
Shopping centersParking lotsSubstationsBuilding facades
PREFERRED SELECTION CATALOG NUMBERS
77 X1M CA MT1 76 0443 TL NL77 X1M CA MT1 76 TM TL NL77 X1S CA MT1 76 0443 TL NL77 X1S CA MT1 76 TM TL NL
159Product Guide
Example: 7 7 X I M C A M T 7 7 6 T M
O R D E R I N G I N F O R M A T I O N
UltraFlood™ Series 77Heavy Duty Floodlight
400-1000W HPS; 400-1000W MH
77 UltraFlood CA CWA (Auto Reg) 120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120V MT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277VTT3 Tri-tap Wired 347VDT2 Dual Tap 120/240
wired 2405T4 5 Tap Wired 480V
40 400W75 750WX1 1000W
S HPSM MH
Mounting(blank) Yoke Mount (standard)1
YG Yoke GalvanizedTM Tenon slipfitter1
Paint2
(blank) Bronze (standard)BK BlackGY Gray
WH White
Terminal Block3
(blank) Hard wired (standard)TB Terminal BlockT2 Wired to L1 and L2T3 3 Wire Operation
(L1, N, L2 Position)8
Listing(blank) UL Listed (standard)
CS CSA CertifiedXL No Listing
Photocontrol Receptacle(blank) Photocontrol Receptacle
NR No Photocontrol Receptacle4
LampLC Lamp Included, ClearLD Lamp Included, Deluxe
Options
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Cord Length* Cord Type*
04 4’ 63 16-305 5’ 44 14-46
06 6’ 43 14-308 8’ 23 12-310 10’ PW Pre-wire (Slip fitter only)12 12’15 15’20 20’25 25’30 30’
Misc.TL Tool Less EntryPC Photocontrol Included per
Voltage Specified4
SS Stainless Steel fasteners (external)5H 50 Hertz Ballast Frequency7
NL NEMA LabelSH Shorting Cap4
Ballast VoltageWattage / SourceSeries
Horizontal Lamp65 6H x 5V66 6H x 6V76 7H x 6V
Refer to opticdistribution matrixbelow for compatibility.
NEMA Beam Pattern
Notes:
1 Painted to match fixture2 Other colors available, please contact your local
American Electric Lighting representative3 Voids UL and CSA certification4 PC, and SH not available with NR option5 Voids UL and CSA listing, not available in MT, TT, & DT
voltages6 For 3-wire operation and ground7 Limited availability, please contact your local
American Electric Lighting representative8 Not available in 120V
*Cord length and type should be combined to form one number. Ex: 0643
65 66 76X1S � � -X1M - - �
Optic Distribution
Refer to the ballast matrix onpage 174 for compatibility.
P R O D U C T O V E R V I E W
160 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Features:Durable polyester powder paint finish
Die-cast aluminum housing
Fully gasketed
Lens secured by hinged, captive bezel with captive screw or NEMA latchclosure
High efficiency aluminum reflector
Provides broad floodlighting coverage
Impact and thermal resistant tempered glass lens
UL listing in standard
Energy Saver Series CESFloodlight35-150W HPS; 50-175W MH
Effective Projected Area (EPA)The EPA for the Energy Saver Series CES is 0.61 sq. ft.Approx. Wt. = 18 lbs.
Applications:Waterfront areasBuilding facadesResidential areasRecreational areasCommercial environmentsParking areasIndustrial sitesStorage areas
PREFERRED SELECTION CATALOG NUMBERS
CES 15S RN 120 LC
161Product Guide
Example: C E S 0 3 S C A 1 2 0 B K
O R D E R I N G I N F O R M A T I O N
Energy Saver Series CESFloodlight
35-150W HPS; 50-175W MH
CES CompactEnergy SaverFloodlight
RN Reactor, NormalPower Factor
RH Reactor, HighPower Factor
XN High Reactance (lag), Normal Power Factor
XH High Reactance (lag), High Power Factor
CA CWA (Auto Reg)
120 120V03 35W05 50W07 70W10 100W15 150W17 175W
S HPSM MH
Mounting(blank) 1/2” Threaded Knuckle Mount
WY Wrap Around Yoke
Paint(blank) Bronze (standard)
BK BlackWH White
Photocontrol Receptacle(blank) None
PC Button Photocontrol
Options
Lamp(blank) None
LC Lamp Included, Clear
Misc.TL Tool Less Entry
Ballast VoltageWattage / SourceSeries
Refer to the ballast matrix onpage 174 for compatibility.
P R O D U C T O V E R V I E W
162 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
DIMENSIONS
Applications:Transportation terminalsBuilding facadesSports lightingParking lotsIndustrial areasCommercial areasResidential areasSecurity lighting
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance, bronze is standard color
Single door access to lamp and electrical components for quick, easyinstallation and servicing
Suitable for -30°C MH / -40°C HPS
UL listing is standard
Lens is thermal shock and impact resistant tempered glass
Effective Projected Area (EPA)The EPA for the Floodlight, Series 570 is 0.72 sq. ft.Approx Wt = 3.5 lbs
570-61/L Clear Lamp Included (120V)
Fixture Available
Quartz Flood Series 570Floodlight500W Quartz
570-61/L
163Product Guide
P R O D U C T O V E R V I E W
Quartz Flood Series 474Floodlight1500W Quartz
DIMENSIONS
Applications:Transportation terminalsBuilding facadesSports lightingParking lotsIndustrial areasCommercial areasResidential areasSecurity lighting
Features:Rugged die-cast aluminum housing is powder-coated for durability andcorrosion resistance, bronze is standard color
Single door access to lamp and electrical components for quick, easyinstallation and servicing
Permanently attached bezel is secured by twin captive spring latches
UL listing is standard
Lens is thermal-, shock-, and impact-resistant tempered glass for lampprotection
474-61/L-208V M4 Lamp Included (208V)474-61/L-240V M4 Lamp Included (240V)474-61/L-277V M4 Lamp Included (277V)
Fixtures Available
Effective Projected Area (EPA)The EPA for the Floodlight, Series 474 is 1.13 sq. ft.Approx Wt = 5.5 lbs
P R O D U C T O V E R V I E W
164 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
P R O D U C T O V E R V I E W
Effective Projected Area (EPA)The EPA for the Sports Floodlight Series SPF is 3.3 sq. ft.Approx. Wt. = 55 lbs.
DIMENSIONS
Features:Two-piece die-cast aluminum ballast housing mounted to galvanized steeltrunnion. Ballast is removable and hinged with captive fastener. Steel trunnionfeatures vertical and horizontal aiming scale with vertical repositioning stop.
All external hardware is stainless steel.
White corrosion resistant polyester powder finish standard; other architecturalcolors available.
Heavy-gauge anodized reflector with six distributions available. "Flux manager"available for optimal glare and spill light control. Transverse mounting of lamp.Lamp support included. Optical chamber sealed to inhibit entrance ofcontaminants. Hinged lens is thermal-, shock- and impact-resistant temperedglass. Lens frame is galvanized and secured by stainless steel spring clips forservicing of lamp. US. Patent no. 6,190,023. Canada Patent no. 2,212,014.
Fixture mounted by securing trunnion directly to cross arm. Mountinghardware provided.
Suitable for -30°C MH / -40°C HPS
UL listed, suitable for wet locations. Below horizontal aiming orientation only.Listed and labeled to comply with Canadian Standards.
All electrical components warranted by American Electric Lighting’s 6-yearguarantee.
Applications:StadiumsSports fieldsArenasTracksCourts
AmeriSport™ Series ASPSports Floodlight400-1500W MH
165Product Guide
O R D E R I N G I N F O R M A T I O N
AmeriSport™ Series ASPSports Floodlight
400-1500W MH
Example: A S P X 5 M C A M T 1 G N
ASP AmeriSport
OpticsBallastWattage / SourceSeries
G General PurposeH Heavy Duty
CA CWASC SCWA
(Pulse Start)1
CT CWI2
40 400WX1 1000WX5 1500W
Notes:1 400W MH only2 Available in 208 and 240V only3 Consult factory for CSA availability4 Single tap only 5 Limited availability, please contact your local
American Electric Lighting representative6 Must use with heavy duty optical7 Must use mating receptacle, provided by others8 Not available with 1500W, 120V9 Use with pre-wired gauges and cross-arms
10 For use with 0363 cord length and type only
Voltage
120 120V208 208V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277V TT3 Tri-tap Wired 277V5T8 5-tap Wired 480V
Listing(blank) UL Listed (standard)
CS CSA Certified3
XL No Listing
Fusing4
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
Cord Length* 03 3' Cord05 5' Cord08 8' Cord
LampLC Lamp Included, Clear
(Ships separately)
Frequency5H 50 Hertz Ballast Frequency5
FilterCF Charcoal Filter6
Connector3P 3 Prong Plug7,8,9,10
Quartz RestrikeQS Quartz Restrike (Lamp not included)
Options
Distribution
N Narrow BeamM Medium BeamW Wide Beam
NX Narrow Beam withFlux Manager
DX Medium Beam withFlux Manager
WX Wide Beam withFlux Manager
M Metal Halide
Cord Type* 23 12-3 SEO Cord43 14-3 SEO Cord63 16-3 SEO Cord
*Cord length and type shouldbe combined to form onenumber. Ex: 0523
166 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
P R O D U C T O V E R V I E W
Sportslighting Series SPFSports Floodlight400W & 1000W HPS, 400W-1500W MH
Features:Heavy-gauge, hydroformed, aluminum ballast housing is mounted to integraldie-cast monoframe with horizontal degree aiming scale and repositioninglocator. Die-cast aluminum socket housing provides vertical aiming adjustment,complete with degree aiming scale and repositioning stop.
Heavy-gauge, anodized, aluminum reflectors provide a range of NEMA beamspreads. Optical chamber is sealed to inhibit entrance of contaminants. Hingedlens is heavy-duty thermal shock and impact-resistant, tempered glass.
Adjustable mounting bracket standard. Porcelain, mogul-base socket withcopper alloy, nickel-plated screw shell and center contact. UL listed 1500W,600V.
Fixture is mounted by securing the integral cross-arm mounting bracket directlyto the cross-arm. No additional adapters are required. A 5/8"-11UNC mountingbolt is provided. Exposed bolt length is 1-1/2".
UL listed, suitable for wet locations. Listed and labeled to comply with CanadianStandards.
Suitable for -30°C MH / -40°C HPS
Optional painted heavy duty reflector shroud available to protect the reflector.
All electrical components warranted by AEL’s 6-year guarantee.
DimensionsEPA: NEMA 2,3: 2.9 ft.2 (.27 m2)
NEMA 4,5,6: 2.5 ft2 (.23 m2)Diameter: NEMA 2,3: 23-1/8 (58.7)
NEMA 4,5,6: 21-1/2 (54.6)Length: NEMA 2,3: 30 (76.2)
NEMA 4,5,6: 31-1/2 (80)Weight: 53 lbs. 24 Kg.
DIMENSIONS
Applications:StadiumsSports fieldsArenasTracksCourts
PREFERRED SELECTION CATALOG NUMBERS
SPF X5M CA MT1 33SPF X5M CA MT1 44SPF X5M CA MT1 66
167Product Guide
O R D E R I N G I N F O R M A T I O N
Sportslighting Series SPFSports Floodlight
400W & 1000W HPS, 400W MH-1500W MH
Example: S P F X 5 M C A M T 1 5 5
SPF SportsFloodlight
BallastWattage / SourceSeries
CA CWASC SCWA (Pulse
Start)2
CT CWI3
40 400WX1 1000WX5 1500W1
Notes:
1 Metal Halide only2 400W MH Only3 Available in 208 and 240V only. Not available in
HPS4 Consult factory for CSA availability4 Must use mating receptacle, provided by others5 Available in single tap only6 Limited availability, please contact your local
American Electric Lighting representative7 Heavy duty anodized aluminum shroud8 Must use mating receptacle, provided by others9 Use with prewired caged and crossarms
10 For use with 0363 cord length and type only11 Not available with 1500W, 120V12 For use with reflector shroud (RS option) only13 Lamp not included14 LV and GS not compatible
Voltage
Listing(blank) UL Listed (standard)
CS CSA Certified4
XL No Listing
Fusing5
SF Single Fuse (120, 277, 347V)DF Double Fuse (208, 220, 240, 480V)
LampLC Lamp Included, Clear
(Ships separately)
Cord Length** 03 3' Cord05 5' Cord08 8' Cord
Frequency 5H 50 Hertz Ballast Frequency6
ShieldGS Glare Shield14
HG Hail Shroud and Glare shieldRS Reflector (Hail) Shroud7
LouverLV Internal Louver14
Options
120 120V208 208V220 220V240 240V277 277V347 347V480 480V
MT1 Multi-tap Wired 120VMT2 Multi-tap Wired 240VMT7 Multi-tap Wired 277V5T4 5-Tap Wired 480V
S HPSM MH
BoltLB Extended Bolt for Wood Crossarm
SupportLT Lamp Support
Connector3P 3 Prong Plug8,9,10,11
CoatingTC Non-stick Protective Coating,
Black Only
AimingAH Above Horizontal
FilterCF Charcoal Filter12
QuartzQS Quartz Restrike13
PaintBK Black
WH White
Optics
22 2H x 2V33 3H x 3V44 4H x 4V55 5H x 5V66 6H x 6V
Cord Type** 23 12-3 SEO Cord43 14-3 SEO Cord63 16-3 SEO Cord
**Cord length and typeshould be combined to formone number. Ex: 0523
168 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
G L A R E S H I E L D S
RK75 GS BZ ULTRA FLOOD GLARE SHIELD .6 2RK75 GS LARGE BZ Manufactured of corrosion-resistant aluminum.
For use with Ultra Flood, series 75. Standardfinish is bronze.
RK75 VS POLYCARBONATE VANDAL SHIELD 2
RK77 GS BZ ULTRA FLOOD GLARE SHIELD .7 2RK77 GS LARGE BZ Manufactured of corrosion-resistant aluminum.
For use with Ultra Flood, series 77. Standardfinish is bronze.
RK77 VS POLYCARBONATE VANDAL SHIELD 2
RKACP GS BZ COMPACT FLOOD GLARE SHIELD .5 2RKACP GS LARGE BZ Manufactured of corrosion-resistant aluminum.
For use with series 51. Standardfinish is bronze.2
RKACP VS COMPACT FLOOD VANDAL SHIELD 2
75 PGS 40W 75 SERIES BALLISTIC SHIELD, 400W MAX77 PGS X1W 77 SERIES BALLISTIC SHIELD, 1000W MAXACP PGS 40W ACP SERIES BALLISTIC SHIELD, 400W MAX
EffectiveCatalog Projected Approx. Number Item Area (Sq. Ft.) Wt. (Lbs.)
Accessories
169Product Guide
S T E E L M O U N T I N G B R A C K E T S
AccessoriesFor Mounting to Wood Poles
EffectiveCatalog Projected Approx.Number Item Area (Sq. Ft.) Wt. (Lbs.)
9201 SINGLE UNIT BRACKET — Manufactured of 2'' steel .7 5pipe with a minimum yield of 35,000 PSI.Requires two 1/2'' lag screws, one 5/8'' through-boltand one 2'' square flat washer. Prime coated finish.
9254 SINGLE UNIT BRACKET — Manufactured of 2'' steel .7 13pipe with a minimum yield of 35,000 PSI.Requires two 1/2'' lag screws, one 5/8'' through-boltand one 2'' square flat washer. Prime coated finish.
9204 SINGLE UNIT BRACKET — Fixture bracket is 3'' - .8 141/4
3''- 5/16'' angle steel with 3/4'' - 11/2'' steel bolts. Unit of2'' steel pipe with minimum yield strength of 35,000 PSI.Requires two 1/2'' lag screws, one 5/8'' through-boltand one 2'' square flat washer. Prime coated finish.
9205 TWIN UNIT BRACKET — Each fixture bracket is 3'' - .8 271/4
3''- 5/16'' angle steel with 3/4'' - 11/2'' steel bolts. Unit of2'' steel pipe with minimum yield strength of 35,000 PSI.Requires two 1/2'' lag screws, one 5/8'' through-boltand one 2'' square flat washer. Prime coated finish.
9252 TWIN UNIT BRACKET — Manufactured of 2'' steel 1.4 249252-G pipe with a minimum yield strength of 35,000 PSI.(Galvanized) Requires two 1/2'' lag screws, one 5/8'' through-bolt
and one 2'' square flat washer. Prime coated finish.
9253 THREE UNIT BRACKET — Manufactured of 2'' steel 1.9 279253-G pipe with minimum yield strength of 35,000 PSI.(Galvanized) Requires two 1/2'' lag screws, one 5/8'' through-bolt
and one 2'' square flat washer. Prime coated finish.
NOTE: Above brackets available with GALVANIZED FINISH, to order add -G suffix to catalog number. (Example: 9252-G.)
M O U N T I N G A D A P T E R S
170 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Catalog Approx.Number Item Wt. (Lbs.)
9902-H ALUMINUM POLE-TOP MOUNT 3Slipfitter mounting. Positive three-point mounting support and corrosion-resistant hardware. Fits 2'' or 21/2'' pipe (2'' pipe intrudes 31/16'', 21/2'' pipe intrudes 23/4''.) Furnished with mounting bolts, set screws, and compression fitting for cable entry. Top cover removable for wiring.
9906 PIPE CLAMP MOUNT 3Plated steel and cast aluminum clamp mount with corrosion-resistant hardware for 11/2'' or 2'' pipe installations.
9909 PIPE CLAMP MOUNT 5Plated steel and cast aluminum clamp mount with corrosion-resistant hardware for 3'' pipe installations.
Accessories
171Product Guide
S T E E L M O U N T I N G B R A C K E T S
AccessoriesFor Mounting to Steel Poles
EffectiveCatalog Projected Approx.Number Item Area (Sq. Ft.) Wt. (Lbs.)
9333 THREE ARM POLE-BRACKET—12'' spread, arms 1.2 34@ 120° 2'' (23/8'' OD) standard pipe tenon and slip-fitter base for mounting to standard 2'' pipe tenons.Prime coated finish.
9343 FOUR ARM POLE-TOP BRACKET—48'' spread, .90 45arms @ 90°, 2'' (23/8'' OD) standard pipe tenon andslipfitter base for mounting to standard 2'' pipetenons. Prime-coated finish.
9352 TWO ARM POLE-TOP BRACKET — 30'' spread, 2'' .87 21(23/8'' OD) standard pipe tenon and slipfitter base formounting to standard 2'' pipe tenons. Prime-coatedfinish.
9353 THREE ARM POLE-TOP BRACKET — 30'' spread 1.7 34between tenons, 2'' (23/8'' OD) standard pipe tenonand slipfitter base for mounting to standard 2'' pipetenons. Prime-coated finish.
9354 FOUR ARM POLE-TOP BRACKET — 30'' spread 2.3 45between tenons, 2'' (23/8'' OD) standard pipe tenonand slipfitter base for mounting to standard 2'' pipetenons. Prime-coated finish.
NOTE: Above brackets available with GALVANIZED FINISH, to order add -G suffix to catalog number. (Example: 9252-G)
For Steel, Aluminum, Fiberglass and Wood Poles Refer to the Pole Section or Call Your Local American Electric Lighting Representative.
A V A I L A B I L I T Y
172 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
Options and Accessories
ACRA ACRA45
9/16" DIA.
ATS USPF TSU
ARWB BZ U Furnished with weather-tight cord
grip for 14-3 SO cord. (Grip for 12-3 SO optional.)
5/8" ClearanceHole
Wire Access
ACP 75 77 ASP SPFFlood Glare Shield, Dark Bronze RKACP GS BZ RK75 GS BZ RK77 GS BZ - -Large Flood Glare Shield, Dark Bronze RKACP GS LARGE BZ RK75 GS LARGE BZ RK77 GS LARGE BZ - -Upper Visor, Glass Lens and Glass Ring for NEMA 4, 5, 61 - - - - SPF20 GS GL OPT UUpper Visor, Glass Lens and Glass Ring for NEMA 2, 31 - - - - SPF23 GS GL OPT UPolycarbonate Vandal Shield RKACP VS RK75 VS RK77 VS - -Ballistic Shield ACP PGS 40W2 75 PGS 40W2 77 PGS X1W3 - -Vertical Single Unit Bracket (19-3/4”H)4, 5 9201 9201 9201 - -Vertical Single Unit Bracket (23”H)4, 5 9254 9254 9254 - -Crossarm Single Unit Bracket4, 6 9204 9204 9204 - -Crossarm Twin Unit Bracket4, 6 9205 9205 9205 - -Vertical Twin Unit Bracket 4, 5 9252 9252 9252 - -Galvanized Vertical Twin Unit Bracket 4, 5 9252-G 9252-G 9252-G - -Vertical Three Unit Bracket 4, 5 9253 9253 9253 - -Galvanized Vertical Three Unit Bracket 4, 5 9253-G 9253-G 9253-G - -Aluminum Pole-Top Mount 9902-H 9902-H 9902-H - -Pipe Clamp Mount for 1-1/2” - 2” Pipe 9906 9906 9906 - -Pipe Clamp Mount for 3” Pipe 9909 9909 9909 - -Three-Arm Pole-Top Bracket (12” spread) 9333 9333 9333 - -Two-Arm Pole-Top Bracket (30” spread) 9352 9352 9352 - -Three-Arm Pole-Top Bracket (30” spread) 9353 9353 9353 -Four-Arm Pole-Top Bracket (30” spread) 9354 9354 9354 -Four-Arm Pole-Top Bracket (48” spread) 9343 9343 9343 - -Crossarm Adapter - - - ACRA -Crossarm Adapter, 45º - - - ACRA45 U -Bottom Internal Louver, Glass Lens and Lens Ring for NEMA 4, 5, 6 - - - - SPF20 LV GL UBottom Internal Louver, Glass Lens and Lens Ring for NEMA 2, 3 - - - - SPF23 LV GL URadius Wall Bracket, Dark Bronze - - - - ARWB BZ USteel Angle Bracket, Dark Bronze - - - - ASAB BZ UMounting Bracket (for 2” Schedule 40 pipe) - - - ASPMB OPT U -Pole-Top Tenon Adapter for 2-3/8” to 2-7/8” OD Tenon - - - ATS U SPFTS UWood Pole, 2-light - - - - ACRW2Wood Pole, 3-light - - - - ACRW3Wood Pole, 4-light - - - - ACRW4
Notes:1 Louver and glare shield cannot be used simultaneously2 400W lamp maximum3 1000W lamp maximum4 Brackets designed to accommodate fixtures with a maximum weight of 65 lbs. and an EPA of 4.05 Tenon mount only6 Yoke mount only
Standard finish is dark bronze, contact American Electric Lighting for other finishes
GLARESHIELDS
MOUNTINGBRACKETS
MOUNTINGADAPTERS
POLE-TOPMOUNTINGBRACKETS
SPORTSFLOOD
ACCESSORIES
173Product Guide
Watts 120 208 240 277 347 480 DT2 MT1 MT207S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN XH,XN XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN10S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN13S RH,RN - - - - - - - -14S RH,RN - - - - - - - -15S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN - CA,XH,XN - CA,CT,XH,XN CA,CT,XH,XN17M CA CA CA CA CA CA CA CA CA20S CA CA RH,RN,CA CA - CA CA CA CA23S CA CA CA CA - - CA CA CA25S XH,XN,CA CA CA, XH, XN CA CA CA CA, CA CA23M CA CA CA CA - - CA,XH,XN CA CA25M CA CA CA CA CA,CT,SC CA,SC CA CA,SC CA,SC31S CA CA CA CA - CA CA,CT,SC CA CA40S CA,CT CA,CT CA,CT CA,CT CA CA CA,CT - -40M CA,CT CA CA,CT CA - CA,SC CA,CT CA,SC CA,SC
B A L L A S T M A T R I C E S
ACP Series
ACP Series continuedWatts MT7 TT3 5T407S CA,CT,XH,XN CT,XH,XN -10S CA,CT,XH,XN CT,XH,XN -13S - - -14S - - -15S CA,CT,XH,XN - -17M CA CA -20S CA CA -23S CA - -25S CA CA,CT CA23M CA - -25M CA,SC CA,CT CA31S CA - -40S - - CA40M CA,SC - CA
ASAB
ACRW2 ACRW3 ACRW4
APSMB OPT U
Floodlighting
174 Product Guide For photometric information, visit our website,www.americanelectriclighting.com
B A L L A S T M A T R I C E S
Watts 120 208 220 240 277 480 DT1 DT2 DT3 DT4 MT1 MT240S CA,CT,XN,XH,MR CA,CT RN,RH RH,RN,CA,CT,MR CA,CT CA,MR CA,CT,,XN,XH,MR CA,CT,,XN,XH,MR MR MR CA,CT CA,CT40M CA,CT,SC CA,CT,SC CA CA,CT,SC CA,SC CA,CT, CA,CT CA,CT CT CT CA,SC CA,SC75S CA CA - CA CA - CA CA - - - -X1S CA,CT CA,CT - CA,CT CA,CT CA,CT CA,CT CA,CT - - CA CAX1M CA,SC CS,SC CA CA,SC CA,SC CA,SC CA,SC CA,SC - - CA,SC CA,SC
Watts 120 208 240 277 DT2 MT1 MT2 MT703S RN,RH - - - - - - -05S RN,RH - - - - - - -05M XN,XH - - XN,XH - - - -07S RN,RH - - - - - - -07M XN,XH - - XN,XH - - - -10S RN,RH - - - - - - -10M XN,XH - - XN,XH - - - -15S RN,RH - - - - - - -15M XN,XH - - XN,XH - - - -17M CA CA CA CA CA CA CA CA
Watts MT7 MT8 TT1 TT7 TT3 34740S CA,CT CA,CT CA CA CA CA40M CA,SC CA,SC CA CA CA CA75S - - - - - -X1S CA CA - - CA -X1M CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC
Series 77
Series 77 continued
Energy Saver Series CES
Floodlighting
Watts 120 208 240 277 347 480 DT2 MT110S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CT,XH,XN CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN15S CA,CT,RH,RN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN - CA,XH,XN - CA,CT,XH,XN17M CA CA CA CA CA CA CA CA20S CA CA CA,RH,RN CA - CA CA CA23S CA CA CA CA - - CA CA25S CA,XH,XN CA CA,XH,XN CA CA CA CA,XH,XN CA23M CA CA CA CA, - - CA CA25M CA CA CA CA CA,CT,SC CA,SC CA,CT,SC CA,SC31S CA CA CA CA - CA CA CA40S CA,CT CA,CT CA,CT CA,CT CA CA CA,CT -40M CA,CT CA CA,CT CA - CA,SC CA,CT CA,SC
Series 75
Watts MT2 MT7 TT3 5T410S CA,CT,XH,XN CA,CT,XH,XN XH,XN,CT -15S CA,CT,XH,XN CA,CT,XH,XN - -17M CA CA CA -20S CA CA CA -23S CA CA - -25S CA CA CA,CT CA23M CA CA - -25M CA,SC CA,SC CA,CT CA31S CA CA - -40S - - - CA40M CA CA - CA
Series 75 continued
DARK TO LIGHT®
American Electric Lighting®
DP 1704 ...................................................................176
DP Series .................................................................177
DE Series .................................................................178
DX Series .................................................................179
DUX Series ..............................................................180
D7790 Series............................................................181
DD Series.................................................................182
DPN Series ..............................................................183
DBE Series...............................................................184
Shorting and Open Caps .......................................185
Photocontrol Accessories ....................................186
Photocontrol Recommendation Chart ................186
ANSI Color Chart ....................................................186
ELECTRONIC PHOTOCONTROLS
175
O R D E R I N G I N F O R M A T I O N
DP 1704 Utility PremiumElectronic Locking Type Photocontrol
176 Product Guide For more information, visit our website,www.americanelectriclighting.com
PREFERRED SELECTION CATALOG NUMBERS
DP124-1.5-1704 J50
Features:Special components provide superior reliability for large wattage fixtures orother applications that overheat or damage ordinary photocontrols
Silicon photocell provides long-term drift-free light sensing at elevatedtemperatures
Heat stabilized polymers are used in the base, enabling the control towithstand the high temperatures found on 400 and 1,000 watt HID floodlights
ANSI standard 1.5 footcandle turn on
Fast delivery from stock
Eight-year warranty
Brown cover for identification
Multi-volt, 120/208/240/277 VAC
MOV surge protection, 320 Joule, 10,000 AMP
“Best of Everything” controlApplications:
Roadway and area lighting
1.5 ANSI StandardDP124 120/208/240/277 Volts (105–305)
Turn-on Level (ftc)1
1704
PremiumVoltage
Ordering Information Example: D P 1 2 4 - 1 . 5 - 1 7 0 4 J 5 0
DIMENSIONS
Job Packs
J50 50 Units
NEW
Notes:1 Other options available,
please contact your local American Electric Lighting representative
Features:Silicon light sensor
Complies with ANSI C136.10-1996
MOV surge protection
Long life
Energy efficient
Six-year warranty
Available in job packs of J12 or J50 only
Heat stabilized polymers are used in the base, enabling the control towithstand the high temperatures found on 400 and 1,000 watt HID floodlightsand other fixtures
Inverse ratio (DPR) and fail off (DPF) options available
Inverse Ratio Controls are ideal for areas where it is important to turn on lightsearly but energy costs are a concern. Turn-off level is lower than turn-onlevels. Model listed, DPR124-2.6-TJBK J50, is most commonly ordered.Various other models available. Contact your local American Electric Lightingrepresentative for details and specifications.
Fail Off Controls are occasionally used for leased lighting. ModelDPF124-1.5-TJ J50 is most commonly ordered. Various other models available.Contact your local American Electric Lighting representative for details andspecifications.
O R D E R I N G I N F O R M A T I O N
DP Series SiliconElectronic Locking Type Photocontrol
Example: D P 1 2 0 - 1 . 5 - T J B K J 5 0Ordering Information
1.0 Energy Saver1.5 ANSI Standard2.6 IES Recommendation8.0 Automile (High
Ambient Light)35 FAA
DP120 120 Volts (105–130)DP124 120/240/277 Volts
(105–305)DP240 240 Volts (185–305)DP347 347 Volts (300–400)DP480 480 Volts (420–530)DPR124 Multi-volt Inverse
ratioDPF124 Multi-volt Fail Off
Turn-on Level (ftc)1
T 2-5 Second Turn-off Delay
Time Delay (seconds)1
J 320 J/10,000 Amp MOV
Surge Protector
(blank) ANSI Standard Color*BK BlackBR Brown
P Upward Facing
* See chart page 186
Cover Color 1Voltage
DIMENSIONS
Notes:1 Other options available, please contact
your local American Electric Lighting representative
Applications:Roadway and area lightingFloodlightsAreas with very high temperatures(DP Series High Temp/Floodlight)
Job Packs
J12 12 UnitsJ50 50 Unit
Upward Facing
PREFERRED SELECTION CATALOG NUMBERS
DP124-1.5-TJ J50DP120-1.5-TJ J50DP124-1.5-TJBK J50
177Product Guide
178 For more information, visit our website,www.americanelectriclighting.com
Product Guide
O R D E R I N G I N F O R M A T I O N
DE Series Filtered SiliconElectronic Locking Type Photocontrol
DIMENSIONS
Upward Facing
Example: D E 1 2 0 - 1 . 5 - T J J 5 0Ordering Information
Features:Filtered silicon light sensor
Human eye spectral response
Complies with ANSI C136.10-1996
MOV surge protection
Long life
Energy efficient
Six-year warranty
Available in job packs of J12 and J50 only
Silicon sensor with infrared blocking filter Polypropylene cover, neoprene gasket, brass legs, acrylic windowBase rated for 120°C
Power consumption: 0.5 watts
Load rating: 1000 watts, 1800 VA ballast
Sealed relay rated for 5000 operations at full load
Turn OFF light level is 1.5 times turn ON.
3.4 ounces each
-40 to +70°C ambient, Up to 90° interface per ANSI
Dielectric strength: 5000 V per ANSI
Applications:Roadway and area lighting Areas with variable sky conditionsAreas with high temperatures
1.0 Energy Saver1.5 ANSI Standard2.6 IES Recommendation8.0 Automile (High
Ambient Light)35 FAA
DE120 120 Volts (105–130)DE124 120/240/277 Volts
(105–305)DE347 347 Volts (300–400)DE480 480 Volts (420–530)
Turn-on Level (ftc)1
T 2-5 Second Turn-off Delay (standard)
Time Delay (seconds)1
J 320 J/10,000 Amp MOV
Surge Protector
(blank) ANSI Standard Color*
BK BlackP Upward Facing
* See chart page 186
Cover Color 1Voltage
Notes:1 Other options available,
please contact your local American Electric Lighting representative
Job Packs
J12 12 UnitsJ50 50 Units
PREFERRED SELECTION CATALOG NUMBERS
DE120-1.5-TJ J50DE124-1.5-TJBK J50DE124-1.5-TJGY J50
179Product Guide
O R D E R I N G I N F O R M A T I O N
Features:Silicon light sensor
Complies with ANSI C136.10-1996
MOV surge protection
Long life
Energy efficient
Economical
Six-year warranty
Available in job packs of J12 or J50 only
Standard 160 joule, 6500 amp MOV rated for multiple surges
Polypropylene cover, Neoprene gasket, brass legs, acrylic window base ratedfor 120°C
Power consumption: 0.5 watts
Load rating: 1000 watts, 1800 VA ballast
Sealed relay rated for 5000 operations at full load
3.4 ounces each
-40 to +70°C ambient, Up to 90° interface per ANSI
Dielectric strength: 5000 V per ANSI
DX SeriesElectronic Locking Type Photocontrol
Applications:Roadway and area lightingSecurity lightingMunicipal lighting
Example: D X 1 2 4 - 1 2 A J 5 0 Ordering Information
1 1.2–3 ftc Turn-on (standard)
DX120 120 Volts (105–130)DX124 120/240/277 Volts
(105–305)DX347 347 Volts (300–400)DX480 480 Volts (420–530)
Turn-on Level (ftc)
2 Silicon Sensor,Time Delay (2-5 seconds)
Sensor
A ANSI Standard*
* See chart page 186
Cover Color Voltage
DIMENSIONS
Job Packs
J12 12 UnitsJ50 50 Units
PREFERRED SELECTION CATALOG NUMBERS
DX124-12A J50DX124-12A J12
O R D E R I N G I N F O R M A T I O N
Features:Silicon light sensor
Complies with ANSI C136.10-1996
MOV surge protection
Long life
Energy efficient
Economical
Six-year warranty
Available in job packs of J12 or J50 only
Standard 160 joule, 6500 amp MOV rated for multiple surges
Polypropylene cover, neoprene gasket, brass legs, acrylic window base ratedfor 120°C
Power consumption: 0.5 watts
Load rating: 1000 watts, 1800 VA ballast
Sealed relay rated for 5000 operations at full load
3.4 ounces each
-40 to +70°C ambient, up to 90° interface per ANSI
Dielectric strength: 5000 V per ANSI
UL listed is standard
DUX SeriesLocking Type Photocontrol – UL Listed
Applications:Area lightingSecurity lightingYard lighting
Example: D U X 1 2 4 - 1 2 A J 5 0 Ordering Information
1 1.2–3 ftc Turn-on (standard)
Turn-on Level (ftc)
A ANSI Standard*P Upward Facing
* See chart page 186
Cover Color
180 Product Guide For more information, visit our website,www.americanelectriclighting.com
DUX120 120 Volts (105–130)DUX124 120/240/277 Volts
(105–305)DUX480 480 Volts (420–530)
2 Silicon Sensor, Time Delay (2-5 seconds)
SensorVoltage Job Packs
J12 12 UnitsJ50 50 Units
DIMENSIONS
Upward Facing
PREFERRED SELECTION CATALOG NUMBERS
DUX124-12A J50DUX124-12A J12
Applications:Replacement for many industry standard locking typephotoocontrols
181Product Guide
O R D E R I N G I N F O R M A T I O N
D7790 SeriesElectronic Locking Type Photocontrol
Features:Silicon light sensor
Complies with ANSI C136.10-1996
Two-year warranty
Standard 190 joule, 4500 amp MOV
Polypropylene cover, Neoprene gasket, brass legs, acrylic window
Base rated for 120°C
Power consumption: 0.5 watts
At 120 VAC Load rating: 1000 watts, 1800 VA ballast
Sealed relay rated for 5000 operations at full load
Instant turn on, 2-5 second turn off
Turn on is 1.5 + 0.5 ftc, turn off is 1.5 times turn on
3.4 ounces each
Available in job packs of J12 or J50 only
-40 to +70°C ambient, Up to 90° interface per ANSI
Dielectric strength: 5000 V per ANSI
D7790 is a replacement for many industry standard type locking photocontrols
Sealed in individual poly bags
Example: D 7 7 9 0 J 5 0
DIMENSIONS
D7790 120/208/240/277 VAC
Voltage
Ordering Information
J12 12 UnitsJ50 50 Units
Job Pack
PREFERRED SELECTION CATALOG NUMBERS
D7790 J50
Features:Regular dusk to dawn operation
Diagnostic feature detects and disables cycling HPS lamps and lamps that fail to start
Extends starting aids life
Flashing or steady LED alerts line crew of problem
Filtered silicon light sensor
2-5 second off delay
MOV surge protection
Complies with ANSI C136.10-1996; not for use on incandescent fixtures
Six-year warranty
Available in job packs of J12 or J50 only
Polypropylene cover, neoprene gasket, brass legs, acrylic window base ratedfor 120°C
Power consumption: 1.0 watts
Load rating: 70-400 watt HPS
Sealed relay rated for 5000 operations at full load
3.8 ounces each
-40 to +70°C ambient, Up to 90° interface per ANSI
Dielectric strength: 5000 V per ANSI
DIMENSIONS
Applications:Roadway and area lightingHigh profile installationsAnywhere cycling lamps are a problemAnywhere starting aid life is a problem
Example: D D 1 2 4 - 1 . 5 - T J A J 5 0Ordering Information
1.5 ANSI StandardDD124 120/208/240/277 Volts (105-305)
Turn-on Level (ftc)
T 2-5 Second Turn-off Delay (standard)
Time Delay (seconds)
J 320J/10,000 AmpMOV
Surge Protector
A After Five Lamp Cycles, Control Turns Lamp Off. NextDusk, Control Turns Lamp On and Cycle DetectionCircuit Restarts
Cycle Detection1Voltage
Notes:1 Available with black cover only2 Cycle Detection Program is set at
factory; program cannot be altered in field
Job Packs
J12 12 UnitsJ50 50 Units
O R D E R I N G I N F O R M A T I O N
DD Series DiagnosticsElectronic Locking Type Photocontrol
182 Product Guide For more information, visit our website,www.americanelectriclighting.com
Product Guide
O R D E R I N G I N F O R M A T I O N
DPN Series Part NightElectronic Locking Type Photocontrol
183
Example: D P N 1 2 4 - 2 . 6 - T J G N J 5 0Ordering Information
DIMENSIONS
Features:Control turns on at dusk and off halfway through the night. Automatically self-adjusts to seasonal time changes, reducing maintenance
Reduces light pollution and light trespass concerns
Filtered silicon photocell provides long-term, drift-free light sensing. The infrared blocking polymer filter gives human eye response.
A 2-5 second off-time delay is provided to avoid turn-off from extraneous light.
Complies with ANSI C136.10-1996
Six-year warranty
Energy Savings
Available in job packs of J12 or J50 only
Polypropylene cover, neoprene gasket, brass legs, acrylic window base ratedfor 120°C
Power consumption: 0.8 watts
Load rating: 1000 watts, 1800 VA ballast
Sealed relay rated for 5000 operations at full load
Turn OFF is at middle of the night.
3.6 ounces each
-40 to +70°C ambient, Up to 90° interface per ANSI
Dielectric strength: 5000 V per ANSI
Applications:Parking lotsArea lightsPark lightsMedia lightingBall fields and courtsPedestrian lighting
1.5 ANSI Standard2.6 Standard
DPN124 120/240/277 Volts (105-305)
Turn-on Level (ftc)1
T 2-5 Second Turn-off Delay (standard)
Time Delay (seconds)
J 320 J/10,000 Amp MOV
Surge Protector
GN Green (only)
Cover Color Voltage Job Packs
J12 12 UnitsJ50 50 Units
Notes:1 Other options available, please contact
your local American Electric Lighting representative
O R D E R I N G I N F O R M A T I O N
DBE Series ButtonElectronic Wire-In Photocontrol
184 Product Guide For more information, visit our website,www.americanelectriclighting.com
Features:Electronic wire-in button photocontrol
Instant turn-on, standard 5-10 second turn-off time delay
Filtered Silicon light sensor
UL listed models available
Filtered silicon light sensor
Voltages 120–347
Complies with ANSI C136.24
Long life
Low maintenance
Six-year warranty
Available in job packs of J12 only
190 Joule MOV surge protection
12”, 200ºC, #16 wire leads
Example: D B E 1 2 0 1 . 5 - T J 1 2
Applications:Park lightingSecurity lightingPost lanternsDecorative and area lighting
Ordering Information
1.5 ANSI StandardDBE120 120 Volts (105–130)DBE240 208/240/277 Volts (200–305)DBE347 347 Volts (300–400)DBE124 120/240/277 Volts (105–305)
Turn-on Level (ftc)
T 5-10 Second Turn-off Delay (standard)
Time Delay (seconds)Voltage
DIMENSIONS
3/8” (18) Straight pipe thread
(blank) No ListingU CSA and
UL Listed
Certification
J12 12 Units
Job Pack
PREFERRED SELECTION CATALOG NUMBERS
DBE124-1.5-T J12DBE120-1.5-T J12
185Product Guide
O R D E R I N G I N F O R M A T I O N
Shorting and Open CapsLocking Type
SHORTING AND OPEN CAPSFor luminaires where lights are to be on continuously (shorting cap)or left off (open cap). Exceeds ANSI C136.10-1996.
Description Catalog Number
Shorting cap. Black Cover D-SHORT-SBK
Shorting cap 320J. MOV surge protection. Black cover. D-SHORT-VBK
Open cap. Red cover. D-OPEN-SRD
DIMENSIONS
PREFERRED SELECTION CATALOG NUMBERS
D-SHORT-SBK J12D-SHORT-VBK J12D-OPEN-SRD J50
O R D E R I N G I N F O R M A T I O N
186 Product Guide For more information, visit our website,www.americanelectriclighting.com
CatalogNumber Description
PHOTOCONTROL RECEPTACLESMounting adapter for connecting photocontrol to net. For pole,
DUR-103 wall and frame mounting. 14” x 14” gage wire. Line = black,Load = red, Neutral = white. Each receptacle meets NEMAand ANSI standards.With bracket and rotating cup with locknut
PHOTOCONTROL TESTCAPD-TESTCAP Lightweight black vinyl cap tests the working operation
of photocontrols during daylight hours. Completelyeliminates direct and reflected light, enabling quick andeasy testing. Not designed for use with hot sticks.Affordably priced.
PHOTOCONTROL DEMO BOXD-DEMO BOX Portable 120 volt test box.
Dimensions: 51/2 x 3 x 21/2 inches.
A C C E S S O R I E S
Photocontrol Accessories
DTL Voltages Light Surge Typical SERIES Type Available Sensor Protection Application Electronic
DP Locking 120 thru 480 Silicon MOV, 320 Joule Roadway Yes
DE Locking 120 thru 480 Filtered MOV, 320 Joule Roadway YesSilicon
DX Locking 120 thru 480 Silicon MOV, 320 Joule C&I + Roadway Yes
DUX Locking, 120 thru 480 Silicon MOV, 320 Joule Where UL YesUL listed is needed
DPN Locking, 120-277 Silicon MOV, 160 Joule Off-Roadway YesPart Night
DD Locking, 120-277 Silicon MOV, 160 Joule Roadway YesDiagnostic
DBE Button 120 and 208-277 Filtered MOV, 190 Joule Utility post top YesSilicon
D7790 Locking 120 thru 347 Silicon MOV, 190 Joule Roadway or export Yes
DPF Locking, 120-277 Silicon MOV, 320 Joule Off-Roadway YesFail OFF
DPR Locking, 120-277 Silicon MOV, 320 Joule Roadway YesInverse Ratio
DPO Locking, 120-277 Silicon MOV, 320 Joule OFF night, ON day YesReverse
Photocontrol Recommendation Chart ANSI Color Chart
ANSI Color Codes
120V Gray240V MaroonMultivolt Dark Blue350V Green480V Yellow
PREFERRED SELECTIONCATALOG NUMBER
DUR-103 J6
PREFERRED SELECTIONCATALOG NUMBER
D-TESTCAP J50
POLES
RSA ...........................................................................192
RTA............................................................................193
RSAH ........................................................................194
SSA ...........................................................................195
SSAH ........................................................................196
RSS ...........................................................................197
RTS............................................................................198
SSS ...........................................................................199
STS............................................................................200
STSH.........................................................................201
Pole Options ............................................................202
Aluminum Mounting Brackets .............................203
Steel Mounting Brackets ......................................204
RTF ............................................................................205
RTFDB.......................................................................206
SSF............................................................................207
STC............................................................................208
SPRTC.......................................................................209
SPRTS.......................................................................213
RTAU.........................................................................216
RTSU.........................................................................220
AMAW / SMAW / Arms for Wood Poles ............222
AMAC / SMAC / Arms for Concrete Poles .........224
SMAWL / Arms for Wall Mount ...........................226
Traditional Wood Pole Arms.................................228
Traditional Concrete Pole Arms...........................229
American Electric Lighting®
Illustrated Samples ................................................188
Wind Map ................................................................189
Florida Wind Rating................................................190
General Information...............................................191
187
I L L U S T R A T E D S A M P L E S
188 Product Guide For more information please visit our website:www.americanelectriclighting.com
Round Tapered Aluminum
Round Straight Aluminum
18”
Square Straight Aluminum
Round Straight Steel
Square Straight Steel
Square Tapered Steel Square Tapered Steel Hinge
Round Tapered Fiberglass
4”Bolt Projection
There are several different pole types available throughout this section. Below are a few examples. Please contact your local American ElectricLighting representative for more information.
189Product Guide
W I N D M A P
Con
tact
AE
L fo
r sp
ecifi
c da
ta.
190 Product Guide For more information please visit our website:www.americanelectriclighting.com
F L O R I D A P O L E W I N D R A T I N G C H A R T
SIDE-MOUNTED LOAD TENON-MOUNTED LOADmax. wt. Max WT/EPA Max WT/EPA Max WT/EPA Max WT/EPA Max WT/EPA Max WT/EPA
Steel that will be used 130mph Zone 140mph Zone 150mph Zone 130mph Zone 140mph Zone 150mph ZoneRTS 20 6-5B 100 14.2 / 100 12.1 / 100 10.3 / 100 13.1 / 100 11.2 / 100 9.5 / 100
25 7-0B 200 10.9 / 200 9.3 / 200 7.9 / 200 10.3 / 200 8.7 / 200 7.4 / 20025 7-0F 200 12.2 / 200 10.4 / 200 8.9 / 200 13.3 / 200 11.3 / 200 9.7 / 20030 8-0B 225 10.0 / 225 8.2 / 225 6.9 / 225 9.5 / 225 7.9 / 225 6.6 / 22530 8-0F 225 19.3 / 225 16.3 / 225 13.9 / 225 18.3 / 225 15.5 / 225 13.2 / 22535 9-5B 225 9.6 / 225 7.6 / 225 5.9 / 225 9.2 / 225 7.3 / 225 5.7 / 22539 9-0F 225 13.9 / 225 11.4 / 225 9.5 / 225 13.3 / 225 11.0 / 225 9.2 / 225
SSS 20 5G 100 10.7 / 100 8.5 / 100 6.7 / 100 10.0 / 100 7.9 / 100 6.2 / 10025 5G 100 5.5 / 100 3.8 / 100 2.4 / 100 5.3 / 100 3.6 / 100 2.4 / 10030 6G 100 4.7 / 100 2.7 / 100 1.0 / 100 4.6 / 100 2.6 / 100 1.1 / 100
AluminumSSA 20 6G 100 5.8 0 2.4 0 0 0
25 6J 100 3.5 0 0 0 0 0
RTA 20 7E 100 7.5 6.4 5.3 7.2 5.8 5.125 8G 200 8.8 7.4 6.2 8.5 6.9 630 8G 200 5.6 4.6 3.7 5.5 4.3 3.730 10G 225 11.4 9.4 7.7 11.2 8.9 7.635 10G 225 8 6.4 5 7.9 6.1 4.9
191Product Guide
O R D E R I N G I N F O R M A T I O N
Example: S S A 1 6 4 G D M 1 9 D D B A E L
All luminaire/pole assemblies require properevaluation to ensure that the structural integrity of theassembly is not compromised when applied inspecific wind conditions. Therefore, the basis for poleselection in this catalog is total weight and effectiveprojected area, EPA (ft2), shown on the individual polecatalog pages. Determination of maximum EPA (ft2)and weight loading must include all luminaires,bracketry, signs, decorations, overhead wires orother equipment that will be mounted to the subjectpole. Luminaire EPA (ft2) and weight data are foundon their respective product pages.
The total effective projected area of the luminairesand brackets shall not exceed the EPA (ft2) listed forthe pole selected at a given wind velocity. Poles thatare to be located in areas of known abnormalconditions will require special consideration. Themap on page 189 gives the wind velocities to be usedin determining luminaire pole compatibility.
Pole Selection ProcedureStep 1. Select the luminaire and decide how many will be mounted per pole. Determine the Effective ProjectedArea, EPA (ft2), which is given on the dimensional information table.
Step 2. Determine the appropriate mounting method for the luminaire. Options include arm, bracket or tenonmounting.
Step 3. Add together the EPA's (ft2) of the luminaire and arm/bracket. Multiply by number of fixtures to bemounted on one pole.
Step 4. Consult the Wind Map on page 189 to determine the basic wind velocity for your area.
Step 5. Select the material (steel or aluminum) and shape (square or round) of the pole. Refer to the “TechnicalInformation” chart on the appropriate pole page.
A. Find the desired nominal mounting height in the second column.
B. Verify that the fixture weight does not exceed the maximum weight listed for the desired pole.
C. Compare your total EPA (ft2) loading with the maximum EPA (ft2) value found in the wind speed column foryour area. Check that the equipment you are using will not exceed this value.
D. If both the weight and EPA (ft2) values do not exceed the values for which the pole is rated, you have selectedthe correct pole. If, however, either one of those numbers exceeds the maximum rated values, compare the EPA(ft2) and fixture weight loads to the next larger pole of the same mounting height.
8–50 feet Sportslighting Poles up to 115 Feet
See website for specificinformation.
3 B 0.1204 C 0.1255 E 0.1566 G 0.1887 J 0.2508 K 0.3129 L 0.219
10 P 0.375
PT Only Open-top PoleAccepts KKS (4" square) and KKR (4-1/2" round) Luminaires
Tenon MountingT20 2-3/8" O.D. (2" NPS)T25 2-7/8" O.D. (2-1/2" NPS)T30 3-1/2" O.D. (3" NPS)T35 4" O.D. (3-1/2" NPS)
Drill MountingDM19 1 at 90°DM28 2 at 180°DM29 2 at 90°DM39 3 at 90°DM49 4 at 90°DM32 3 at 120° (Round Poles)
(blank) ASA & AVLA Sq Pole 53B Sq Pole 153C Sq Pole LS, LM, LLD Rd Pole 53 & 153E AVL w/A4 Option
Architectural Colors1
Polyester PowderStandard Colors
DDB Dark bronzeDWH White
DBL BlackBA Brushed
Aluminum2
Class 1 Architectural Anodize (Aluminum only)
ABL Black ADB Dark bronze ANA Natural
NOTES:1 Other colors available, please contact your local
American Electric Lighting representative.2 Aluminum poles only.
RTA Round Tapered AluminumRSA Round Straight Aluminum
RSAH Round Straight Aluminum HingedSSA Square Straight Aluminum
SSAH Square Straight Aluminum HingedRTS Round Tapered SteelSTS Square Tapered Steel
STSH Square Tapered Steel HingedRSS Round Straight SteelSSS Square Straight SteelSSF Square Straight FiberglassRTF Round Tapered Fiberglass
RTFDB Round Tapered Fiberglass Direct Burial
SPRTC Round Tapered ConcreteSportslighting
STC Square Tapered ConcreteSPRTS Round Tapered Steel
Sportslighting
Nominal shaft basesize/wall
thickness (in.)
Fixture Mounting Method
Nominal mounting height
Shaft type
Drill Mounting
See Page202
Options Finish
CAUTION: This pole selection process is a guideline only. American Electric Lighting assumes no responsibilityfor selection and recommends consultation with qualified individuals for verification of luminaire/pole assemblyselection.
PolesGeneral Information
Poles are available only in US
Note: If during the pole warranty period of one year, theproduct proves defective in material or workmanship, thecompany shall correct, at its option, by repairing or replacingat no charge to the purchaser, if the purchaser promptlynotifies the company. This warranty specifically excludesfatigue failure or similar phenomena resulting from inducedvibration harmonic oscillation or resonance associated withthe movement of air currents around the product.
Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, thenadd AEL after the last option
Shaft Bolt Bolt Base WarehouseBase circle projection square Anchor Bolt Template size A B C description number
4" 6-1/2"–8-1/4" 3-1/4" 8-3/4" AB18-0 PJ500574-1/2" 7–8-1/2" 3-1/4" 8-1/2" AB18-0 PJ50040
5" 7-1/2"–9-1/2" 3-1/4" 9-1/4" AB18-0 PJ500586" 8-3/4"–10-1/4" 3-1/2" 10-1/4" AB30-0 PJ500593" 5-1/2"–7" 4-1/8" 10-1/2" AB36-0 PJ501254" 6-5/16”–7-3/8" 4-1/4" 11-1/2" AB36-0 PJ501265” 7-3/8"–8-1/2" 4-1/2" 14-1/2" N/A PJ50127
4 Bolt Base
3 Bolt Base
Pole Data1
1 Pole Data for RSA, page 192
P R O D U C T O V E R V I E W
192 Product Guide For more information please visit our website:www.americanelectriclighting.com
NOTES:For Pole Data Chart, see page 191
Intended UseFor 8’ to 30’ mounting height.
Features:Shaft – One-piece extruded 6063-T6 aluminum alloy with T6 temper.Circumferential satin-brushed finish. 4 1/2" round straight tube isuniform in cross-section down length of shaft.
Anchor Base – Cast from A356 aluminum alloy and heat treated to T6temper. Base slipfits shaft, and they are joined together by continuouscircumferential welds at both top and bottom of anchor base toprovide maximum strength at area of critical stress.
Anchor Bolts – Top 12" is galvanized per ASTM A-153. Made of carbonsteel bar with a minimum-yield strength of 55,000 psi.
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall Bolt Bolt Approx.Catalog mount. Shaft Size Thick. 80 90 100 Max. Circle Size ship wt.Number ht. (ft.) (in. dia. x ft.) (in.) mph mph mph wt. (in.) (in. x in. x in.) (lbs.)
4 Bolt BaseRSA 8 4C 8 4.0 x 8.0 0.125 11.2 8.6 6.8 125 6-1/2-8-1/4 3/4 x 18 x 3 22RSA 10 4C 10 4.0 x 10.0 0.125 8.2 6.1 4.7 100 6-1/2-8-1/4 3/4 x 18 x 3 26RSA 12 4C 12 4.0 x 12.0 0.125 6.0 4.3 3.2 110 6-1/2-8-1/4 3/4 x 18 x 3 30RSA 14 4C 14 4.0 x 14.0 0.125 4.1 2.8 1.9 75 6-1/2-8-1/4 3/4 x 18 x 3 35RSA 14 4-5C 14 4.5 x 14.0 0.125 5.8 4.2 3.3 60 7-1/8-8-3/8 3/4 x 18 x 3 42RSA 14 5C 14 5.0 x 14.0 0.125 7.8 6.0 4.7 100 7-1/2-9-1/2 3/4 x 18 x 3 39RSA 16 4C 16 4.0 x 16.0 0.125 2.8 1.6 1.0 150 6-1/2-8-1/2 3/4 x 18 x 3 38RSA 16 4-5C 16 4.5 x 16.0 0.125 4.2 2.8 2.1 50 7-1/8-8-3/8 3/4 x 18 x 3 46RSA 16 4-5G 16 4.5 x 16.0 0.188 7.5 5.5 4.3 155 7-1/8-8-3/8 3/4 x 18 x 3 62RSA 16 5C 16 5.0 x 16.0 0.125 5.9 4.4 3.4 175 7-1/2-9-1/2 3/4 x 18 x 3 46RSA 16 5E 16 5.0 x 16.0 0.156 8.0 6.1 4.8 190 7-1/2-9-1/2 3/4 x 18 x 3 53RSA 18 4-5G 18 4.5 x 18.0 0.188 5.7 4.0 3.1 123 7-1/8-8-3/8 3/4 x 18 x 3 68RSA 18 5C 18 5.0 x 18.0 0.125 4.3 3.1 2.4 150 7-1/2-9-1/2 3/4 x 18 x 3 48RSA 18 5E 18 5.0 x 18.0 0.156 6.1 4.6 3.5 175 7-1/2-9-1/2 3/4 x 18 x 3 58RSA 18 5G 18 5.0 x 18.0 0.188 8.0 6.8 4.7 225 7-1/2-9-1/2 3/4 x 18 x 3 68RSA 20 4-5G 20 4.5 x 20.0 0.188 4.3 2.9 2.1 95 7-1/8-8-3/8 3/4 x 18 x 3 74RSA 20 5C 20 5.0 x 20.0 0.125 3.0 2.1 1.5 150 7-1/2-9-1/2 3/4 x 18 x 3 54RSA 20 5E 20 5.0 x 20.0 0.156 4.7 3.4 2.6 150 7-1/2-9-1/2 3/4 x 18 x 3 68RSA 20 5G 20 5.0 x 20.0 0.188 6.4 4.8 3.6 150 7-1/2-9-1/2 3/4 x 18 x 3 82RSA 20 6E 20 6.0 x 20.0 0.156 9.3 7.1 5.5 175 8-3/4-10-1/4 3/4 x 30 x 3 95RSA 25 4-5G 25 4.5 x 25.0 0.188 1.3 — — 100 7-1/8-8-3/8 3/4 x 18 x 3 89RSA 25 6E 25 6.0 x 25.0 0.156 5.2 3.8 2.8 150 8-3/4-10-1/4 3/4 x 30 x 3 108RSA 25 6G 25 6.0 x 25.0 0.188 7.1 5.3 4.0 150 8-3/4-10-1/4 3/4 x 30 x 3 128RSA 30 6G 30 6.0 x 30.0 0.188 3.5 2.4 1.6 200 8-3/4-10-1/4 3/4 x 30 x 3 1463 Bolt Base3RSA 8 3C 8 3.0 x 8.0 0.125 5.8 4.3 3.3 75 5-1/2-7 3/4 x 18 x 3 223RSA 10 3C 10 3.0 x 10.0 0.125 4.0 2.9 2.3 75 5-1/2-7 3/4 x 18 x 3 263RSA 10 4C 10 4.0 x 10.0 0.125 8.2 6.1 4.7 75 6-5/16-7-3/8 3/4 x 18 x 3 263RSA 12 3C 12 3.0 x 12.0 0.125 2.7 1.8 1.2 75 5-1/2-7 3/4 x 18 x 3 303RSA 12 4C 12 4.0 x 12.0 0.125 5.8 4.2 3.1 150 6-5/16-7-3/8 3/4 x 18 x 3 303RSA 12 5C 12 5.0 x 12.0 0.125 10.3 8 6.3 150 7-3/8-8-1/2 3/4 x 18 x 3 363RSA 14 3C 14 3.0 x 14.0 0.125 1.7 1.0 0 75 5-1/2-7 3/4 x 18 x 3 353RSA 14 4C 14 4.0 x 14.0 0.125 4.1 2.8 1.9 150 6-5/16-7-3/8 3/4 x 18 x 3 353RSA 14 5C 14 5.0 x 14.0 0.125 7.9 6.0 4.7 150 7-3/8-8-1/2 3/4 x 18 x 3 393RSA 16 4C 16 4.0 x 16.0 0.125 2.8 1.6 1.0 150 6-5/16-7-3/8 3/4 x 18 x 3 383RSA 16 5E 16 5.0 x 16.0 0.156 8.0 6.1 4.8 150 7-3/8-8-1/2 3/4 x 18 x 3 533RSA 18 5C 18 5.0 x 18.0 0.125 4.3 3.1 2.4 150 7-3/8-8-1/2 3/4 x 18 x 3 483RSA 20 5C 20 5.0 x 20.0 0.125 2.9 2.0 1.4 150 7-3/8-8-1/2 3/4 x 18 x 3 543RSA 20 5E 20 5.0 x 20.0 0.156 4.6 3.3 2.5 150 7-3/8-8-1/2 3/4 x 18 x 3 68
Grounding – Ground lug located immediately inside handhole is tapped for ground bolt (not supplied by others).
Handhole – A nominal 2” x 4” or 3” x 5” reinforced handhole iscentered 18” above the base. Cover and attachment hardwarefurnished.
Hardware – Stainless steel.
Top Cap – Cast-aluminum cap is provided for drill-mount poles.
Finish – Standard finish is brushed aluminum. Optional polyesterpowder paint and anodized finishes available.
Bolt Covers – A356 nut covers included with anchor base unlessotherwise specified.
INSTALLATION NOTES:Installation requires grout to be packed under baseto ensure full contact with foundation. Factory-supplied templates must be used when settinganchor bolts. American Electric Lighting will notaccept claim for incorrect anchorage placement dueto failure to use American Electric Lighting factorytemplates.Do not erect poles without having fixtures installed.If poles are stored outside, all protective wrappingmust be removed immediately upon delivery toprevent finish damage.
RSAAnchor Base PolesRound Straight Aluminum
Ordering Information: See page 191(Note: Poles are available only in U.S.)
193Product Guide
P R O D U C T O V E R V I E W
RTAAnchor Based Poles
Round Tapered Aluminum
FeaturesShaft – The shaft is spun tapered from seamless 6063 alloy aluminumtubing and is heat-treated to produce a T6 temper. The shaft is conetapered to the butt diameter.
Anchor Base – Cast from A356 alloy aluminum, the anchor base isheat-treated to a T6 condition. The anchor base telescopes the poleshaft and is circumferentially welded top and bottom.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of steel rodhaving a minimum yield strength of 55,000 PSI.
Ordering Information: See page 191(Note: Poles are available only in U.S.)
Grounding – A ground lug located immediately inside the handhole istapped for 3/8”-16 UNC ground bolt (by others).
Handhole – A nominal 3"x5" or 4"x6" reinforced flush coveredhandhole is centered 18" above the base.
Hardware – Stainless steel.
Top Cap – Cast-aluminum cap is provided for drill mount poles.
Finish – Standard finish is brushed aluminum. Optional polyesterpowder paint and anodized finishes available.
Bolt Covers – A356 nut covers shall be included with each anchorbase unless otherwise specified.
Intended UseFor 20’ to 39’ mounting height.
NOTES:• Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D.
(2" NPS)• Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures
at 180°• Options: See page 202• Brackets: See page 203-204
18”
INSTALLATION NOTES:
Installation requires grout to be packed under base toensure full contact with foundation. Factory-suppliedtemplates must be used when setting anchor bolts.American Electric Lighting will not accept claim forincorrect anchorage placement due to failure to useAmerican Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrappingmust be removed immediately upon delivery toprevent finish damage.
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall ApproxCatalog mount Shaft Size Thickness 80 90 100 Max. Bolt Circle Bolt Size ship wt.Number ht. (ft.) (in. x in. x ft.) (in.) mph mph mph wt. (in.) (in. x in. x in.) (lbs.)
4 Bolt BaseRTA 20 5C 20 5 x 3 x 19’8” 0.125 3.9 2.5 1.6 100 7-1/2-9-1/2 3/4 x 18 x 3 62RTA 20 5G 20 5 x 3 x 19’8” 0.188 7.4 5.2 3.8 100 7-1/2-9-1/2 3/4 x 18 x 3 72RTA 20 6G 20 6 x 4 x 19’8” 0.188 12.2 9.2 7.2 214 9–10 3/4 x 30 x 3 107RTA 20 7E 20 7 x 4 x 19’8” 0.156 15.0 11.4 9.0 256 9-7/8-11-1/4 1 x 36 x 4 103RTA 25 6E 25 6 x 4 x 24’ 8” 0.156 5.3 3.6 2.6 114 9–10 3/4 x 30 x 3 106RTA 25 7E 25 7 x 4 x 24’8” 0.156 9.5 7.0 5.4 162 9-7/8-11-1/4 1 x 36 x 4 120RTA 25 8E 25 8 x 4.5 x 24’ 8” 0.156 14.2 10.9 8.5 220 11–12 1 x 36 x 4 130RTA 25 8G 25 8 x 4.5 x 24’ 8” 0.188 18.0 13.8 10.9 261 11–12 1 x 36 x 4 153RTA 30 7E 30 7 x 4 x 29’8” 0.156 5.5 3.8 2.7 111 9-7/8-11-1/4 1 x 36 x 4 135RTA 30 8E 30 8 x 4.5 x 29’8” 0.156 9.4 7.0 5.3 151 11–12 1 x 36 x 4 150RTA 30 8G 30 8 x 4.5 x 29’8” 0.188 12.4 9.4 7.3 179 11–12 1 x 36 x 4 175RTA 30 10G 30 10 x 6 x 29’8” 0.188 23.8 18.3 14.3 377 14-1/4-16-1/4 1 x 40 x 4 235RTA 35 8E 35 8 x 4.5 x 34’8” 0.156 5.8 4.1 2.9 119 11–12 1 x 36 x 4 185RTA 35 8G 35 8 x 4.5 x 34’8” 0.188 8.3 6.0 4.5 141 11–12 1 x 36 x 4 220RTA 35 8J 35 8 x 4.5 x 34’8” 0.250 12.9 9.7 7.5 183 11–12 1 x 36 x 4 251RTA 35 10G 35 10 x 6 x 34’8” 0.188 17.9 13.6 10.4 295 14-1/4-16-1/4 1 x 40 x 4 268RTA 39 8G 39 8 x 4.5 x 38’8” 0.188 5.6 3.9 2.7 122 11–12 1 x 36 x 4 250RTA 39 8J 39 8 x 4.5 x 38’8” 0.250 9.7 7.1 5.4 158 11–12 1 x 36 x 4 280RTA 39 10G 39 10 x 6 x 38’8” 0.188 14.2 10.5 7.8 253 14-1/4-16-1/4 1 x 40 x 4 295RTA 39 10J 39 10 x 6 x 38’8” 0.250 20.4 15.5 11.9 300 14-1/2-16 1-1/4 x 48 x 5 3733 Bolt Base3RTA 8 4C 8 4.0 x 8.0 0.125 12.1 9.3 7.3 75 6-1/2–7-1/4 3/4 x 18 x 3 n/a3RTA 10 4C 10 4.0 x 10.0 0.125 8.8 6.7 5.2 75 6-1/2–7-1/4 3/4 x 18 x 3 n/a3RTA 12 4C 12 4.0 x 12.0 0.125 6.6 4.8 3.6 75 6-1/2–7-1/4 3/4 x 18 x 3 n/a3RTA 14 4C 14 4.0 x 14.0 0.125 4.9 3.4 2.4 75 6-1/2–7-1/4 3/4 x 18 x 3 n/a3RTA 16 4C 16 4.0 x 16.0 0.125 3.5 2.3 1.5 75 6-1/2–7-1/4 3/4 x 18 x 3 n/a3RTA 16 5C 16 5.0 x 16.0 0.125 6.9 5.0 3.8 75 7-1/2-8-1/2 3/4 x 18 x 3 n/a3RTA 18 5C 18 5.0 x 18.0 0.125 5.0 3.5 2.5 150 7-1/2-8-1/2 3/4 x 18 x 3 n/a3RTA 18 5E 18 5.0 x 18.0 0.156 7.0 5.0 3.7 150 7-1/2-8-1/2 3/4 x 18 x 3 n/a3RTA 20 5C 20 5.0 x 20.0 0.125 3.8 2.5 1.6 150 7-1/2-8-1/2 3/4 x 18 x 3 623RTA 20 5E 20 5.0 x 20.0 0.156 5.5 3.8 2.6 150 7-1/2-8-1/2 3/4 x 18 x 3 70
Shaft Bolt Bolt Base Anchor WarehouseBase circle projection square Bolt Anchor Bolt Template size A B C description description number
5" 7-1/2"–9-1/2" 3-1/4" 9-1/4" ABRTA-5 AB18-0 PJ500326" 9"–10" 3-1/2" 10" ABRTA-6 AB30-0 PJ500337" 9-7/8"–11-1/4" 4-1/8" 10-1/2" ABRTA-7 AB36-0 PJ500348" 11-12" 4-1/4" 11-1/2" ABRTA-8 AB36-0 PJ50035
10"G 14-1/4"–16-1/4" 4-1/2" 14-1/2" ABRTA-10G N/A PJ5003610"J 14-1/2"–16" 5" 14-1/2" ABRTA-10J N/A PJ50063
4" 6-1/2"–7-1/4" 3-1/4" 8-7/8" ABRTA-5 AB18-0 PJ501285" 7-1/2"–8-1/2" 3-1/4" 10-1/4" ABRTA-5 AB18-0 PJ50129
4 Bolt Base
3 Bolt Base
Pole Data
P R O D U C T O V E R V I E W
194 Product Guide For more information please visit our website:www.americanelectriclighting.com
RSAHAnchor Base PolesRound Straight Aluminum, Hinged
Intended UseFor 10’ to 20’ mounting height.
Pole DataShaft Bolt Bolt Base WarehouseBase circle projection square Anchor Bolt Template size A B C description number
4" 8-1/2"–10" 3-1/2" 12-5/8" AB18-0 PJ500605" 8-1/2"–10" 3-1/2" 12-5/8" AB18-0 PJ500616" 8-1/2"–10" 3-1/2" 12-5/8" AB30-0 PJ50062
NOTES:• Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)• Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°• Options: See page 202• Brackets: See page 203-204
INSTALLATION NOTES:
Installation requires grout to be packed under base toensure full contact with foundation. Factory-suppliedtemplates must be used when setting anchor bolts.American Electric Lighting will not accept claim forincorrect anchorage placement due to failure to useAmerican Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrappingmust be removed immediately upon delivery toprevent finish damage.
FeaturesShaft – One-piece extruded 6063 aluminum alloy with a T6 temper.Circumferential satin-brushed finish. The round, straight tube isuniform in cross-section down the length of the shaft.
Hinged Anchor Base – Cast from A356 aluminum alloy, the anchorbase is heat-treated to a T6 temper. The shaft inserts into the tiltingsection of the hinged base and is joined together by continuouscircumferential welds at the outside top and inside bottom. The tiltingand anchored sections of the hinged base are joined by a 3/4"diameter solid aluminum pivot rod. The tilting section of the hingedbase is held in a vertical position by three 1/2”"-13 x 2 1/2" stainlesssteel hex head bolts which attach to stainless steel inserts cast intothe aluminum base. A cast-aluminum two-piece cover is included.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of carbonsteel bar having a minimum-yield strength of 55,000 PSI.
Grounding – Base plate tapped for 3/8”-16 UNC ground bolt (providedby others).
Handhole – Available as an option, and located 90o to the right of thehinge.
Hardware – Stainless steel.
Top Cap – Removable cast-aluminum top cap is provided for drillmount poles.
Finish – Standard finish is brushed aluminum. Optional polyesterpowder painted and anodized finishes available.
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall Bolt Bolt Approx.Catalog mount. Shaft Size Thick. 80 90 100 Max. Circle Size ship wt. Number ht. (ft.) (in. x in. x ft.) (in.) mph mph mph wt. (in.) (in. x in. x in.) (lbs)
RSAH 10 4C 10 4 x 4 x 10 0.125 8.2 6.1 4.7 100 8-1/2-10 3/4 x 18 x 3 43RSAH 14 4C 14 4 x 4 x 14 0.125 4.4 3.0 2.1 100 8-1/2-10 3/4 x 18 x 3 50RSAH 14 5E 14 5 x 5 x 14 0.156 10.6 8.2 6.5 100 8-1/2-10 3/4 x 18 x 3 66RSAH 16 4C 16 4 x 4 x 16 0.125 3.1 1.9 1.2 100 8-1/2-10 3/4 x 18 x 3 54RSAH 16 5C 16 5 x 5 x 16 0.125 6.2 4.7 3.6 100 8-1/2-10 3/4 x 18 x 3 60RSAH 16 6E 16 6 x 6 x 16 0.156 13.8 10.7 8.5 100 8-1/2-10 3/4 x 30 x 3 88RSAH 18 5C 18 5 x 5 x 18 0.125 4.5 3.3 2.5 130 8-1/2-10 3/4 x 18 x 3 65RSAH 18 5G 18 5 x 5 x 18 0.188 8.2 6.2 4.9 130 8-1/2-10 3/4 x 18 x 3 90RSAH 20 5C 20 5 x 5 x 20 0.125 3.2 2.2 1.6 130 8-1/2-10 3/4 x 18 x 3 69RSAH 20 5G 20 5 x 5 x 20 0.188 6.4 4.8 3.7 130 8-1/2-10 3/4 x 18 x 3 97RSAH 20 6G 20 6 x 6 x 20 0.188 11.7 9.0 7.1 130 8-1/2-10 3/4 x 30 x 3 110
Ordering Information: See page 191(Note: Poles are available only in U.S.)
Tapped 3/8” - 16 for ground connector
195Product Guide
P R O D U C T O V E R V I E W
SSAAnchor Base PolesSquare Straight Aluminum
FeaturesShaft – Square, non-tapered shaft made from extruded 6063-T6 or6061-T6 aluminum alloy Shaft width is 4, 5 or 6 inches. Wall thicknessis .125, .188 or .250, depending on mounting height and loadingrequirements.
Anchor Base – Cast from 356-T6 aluminum alloy. Anchor bolt holesare recessed and covered by aluminum caps.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4" or 1"diameter steel rod having minimum-yield strength of 55,000 psi.
Grounding – Ground lug located immediately inside handhole istapped for 3/8"-16 UNC ground bolt (provided by others).
Handhole – Reinforced handhole having nominal dimensions 2" x 4"(4" sq.) or 2 1/2” x 4" (5" or 6" sq.). Handhole cover plate made fromaluminum alloy with attachment hardware provided.
Hardware – Stainless steel.
Top Cap – Removable cast-aluminum top cap is provided for drillmount poles.
Finish – Brushed aluminum is standard; optional polyester powderpaint and anodized finishes available.
Bolt Covers – Nut covers included with each anchor base.
Intended UseFor 4’, 5’ or 6’ shaft width, 8’ to 35’ mounting height.
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall Bolt Bolt Approx.Catalog mount. Shaft Size Thick. 80 90 100 Max. Circle Size ship wt.Number ht. (ft.) (in. x in. x ft.) (in.) mph mph mph wt. (in.) (in. x in. x in.) (lbs.)
SSA 8 4C 8 4.0 x 8.0 0.125 16.5 12.6 9.9 300 8-1/2-9-5/8 3/4 x 18 x 3 32SSA 10 4C 10 4.0 x 10.0 0.125 11.5 8.6 6.5 230 8-1/2-9-5/8 3/4 x 18 x 3 37SSA 12 4C 12 4.0 x 12.0 0.125 12.4 9.2 6.9 160 8-1/2-9-5/8 3/4 x 18 x 3 40SSA 14 4C 14 4.0 x 14.0 0.125 9.3 6.7 4.8 120 8-1/2-9-5/8 3/4 x 18 x 3 50SSA 15 4C 15 4.0 x 15.0 0.125 8.0 5.6 3.9 100 8-1/2-9-5/8 3/4 x 18 x 3 52SSA 16 4C 16 4.0 x 16.0 0.125 6.9 4.7 3.1 90 8-1/2-9-5/8 3/4 x 18 x 3 54SSA 16 4G 16 4.0 x 16.0 0.188 11.8 8.5 6.2 130 8-1/2-9-5/8 3/4 x 30 x 3 74SSA 16 5G 16 5.0 x 16.0 0.188 15.0 11.1 7.5 280 10-1/2-11-1/2 3/4 x 30 x 3 83SSA 18 4C 18 4.0 x 18.0 0.125 4.9 3.0 1.7 70 8-1/2-9-5/8 3/4 x 18 x 3 57SSA 18 4G 18 4.0 x 18.0 0.188 9.2 6.4 4.4 100 8-1/2-9-5/8 3/4 x 30 x 3 80SSA 18 5G 18 5.0 x 18.0 0.188 16.8 12.2 8.9 230 10-1/2-11-1/2 3/4 x 30 x 3 91SSA 20 4C 20 4.0 x 20.0 0.125 3.3 1.7 0.5 40 8-1/2-9-5/8 3/4 x 18 x 3 62SSA 20 4G 20 4.0 x 20.0 0.188 7.0 4.6 2.9 80 8-1/2-9-5/8 3/4 x 30 x 3 85SSA 20 5G 20 5.0 x 20.0 0.188 13.6 9.5 6.6 180 10-1/2-11-1/2 3/4 x 30 x 3 107SSA 20 6G 20 6.0 x 20.0 0.188 22.0 15.9 11.6 230 12-13 1 x 36 x 4 155SSA 20 6J 20 6.0 x 20.0 0.250 30.4 22.6 17.0 300 12-13 1 x 36 x 4 202SSA 25 5G 25 5.0 x 25.0 0.188 7.2 4.2 2.0 110 10-1/2-11-1/2 3/4 x 30 x 3 130SSA 25 6G 25 6.0 x 25.0 0.188 13.2 8.6 5.4 180 12-13 1 x 36 x 4 180SSA 25 6J 25 6.0 x 25.0 0.250 19.7 13.8 9.5 250 12-13 1 x 36 x 4 224SSA 30 6G 30 6.0 x 30.0 0.188 7.0 3.4 0.8 130 12-13 1 x 36 x 4 210SSA 30 6J 30 6.0 x 30.0 0.250 12.2 7.5 4.1 170 12-13 1 x 36 x 4 258SSA 32 6J 32 6.0 x 32.0 0.250 9.7 5.4 2.3 160 12-13 1 x 36 x 4 272SSA 35 6J 35 6.0 x 35.0 0.250 6.4 2.6 — 200 12-13 1 x 36 x 4 294SSA 35 7J 35 6.0 x 35.0 0.250 7.6 3.1 — 150 14-1/8–15-1/8 1 x 36 x 4 290
NOTES:• Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)• Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°• Options: See page 202• Brackets: See page 203-204
Pole DataShaftBolt Bolt Base Anchor
Base circle projection square Anchor Bolt Template size A B C description number
4"C 8-1/2–9-5/8" 3-1/8" 9-15/16" AB18-0 PJ500454"G 8-1/2–9-5/8" 3-1/8" 9-15/16" AB30-0 PJ500455" 10-1/2–11-1/2" 3-1/4" 11-9/16" AB30-0 PJ500466" 12"-13" 4" 12-1/4" AB36-0 PJ500447" 14-1/8–15-1/8" 4-1/4" 15-1/8" AB36-0 PJ50130
Ordering Information: See page 191(Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Installation requires grout to be packed under base toensure full contact with foundation. Factory-suppliedtemplates must be used when setting anchor bolts.American Electric Lighting will not accept claim forincorrect anchorage placement due to failure to useAmerican Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrappingmust be removed immediately upon delivery toprevent finish damage.
Tapered 3/8”-16 forground connector
P R O D U C T O V E R V I E W
196 Product Guide For more information please visit our website:www.americanelectriclighting.com
Intended UseFor 10’ to 20’ mounting height.
FeaturesShaft – Square, non-tapered shaft made from extruded 6063-T6aluminum alloy. Shaft width is 4 or 5 inches. Wall thickness is .125 or.188 depending on mounting height and loading requirements.
Hinged Anchor Base – Cast from A356 aluminum alloy and heattreated to a T6 temper. The shaft inserts into the tilting section of thehinged base and is joined together by continuous circumferentialwelds at the outside top and inside bottom. The tilting and anchoredsections of the hinged base is held in a vertical position by three1/2"–13 x 2 1/2" stainless steel hex head bolts which attach tostainless steel inserts cast into the aluminum base. A cast-aluminumtwo-piece cover is included.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4”diameter steel rod having minimum-yield strength of 55,000 psi.
Grounding – Base plate tapped for 3/8”-16 UNC ground bolt (providedby others).
Handhole – Available as an option, and located 90o to the right of thehinge.
Hardware – Stainless steel.
Top Cap – Removable cast-aluminum top cap is provided for drillmount poles.
Finish – Brushed aluminum is standard; optional polyester powderpaint and anodized finishes available.
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall Bolt Bolt Approx.Catalog mount. Shaft Size Thick. 80 90 100 Max. Circle Size ship wt.Number ht. (ft.) (in. x in. x ft.) (in.) mph mph mph wt. (in.) (in. x in. x in.) (lbs.)
SSAH 10 4C 10 4 x 4 x 10 0.125 13.1 9.9 7.5 100 8-1/2-10 3/4 x 18 x 3 48 SSAH 12 4C 12 4 x 4 x 12 0.125 9.6 7.0 5.1 100 8-1/2-10 3/4 x 18 x 3 53SSAH 14 4C 14 4 x 4 x 14 0.125 7.0 4.9 3.3 100 8-1/2-10 3/4 x 18 x 3 57SSAH 15 4C 15 4 x 4 x 15 0.125 6.0 4.0 2.6 100 8-1/2-10 3/4 x 18 x 3 60SSAH 16 4C 16 4 x 4 x 16 0.125 5.0 3.2 1.9 100 8-1/2-10 3/4 x 18 x 3 62SSAH 16 4G 16 4 x 4 x 16 0.188 8.9 6.2 4.3 150 8-1/2-10 3/4 x 30 x 3 86SSAH 18 4C 18 4 x 4 x 18 0.125 3.4 1.8 0.7 100 8-1/2-10 3/4 x 18 x 3 67SSAH 18 4G 18 4 x 4 x 18 0.188 6.8 4.5 2.9 100 8-1/2-10 3/4 x 30 x 3 93SSAH 18 5G 18 5 x 5 x 18 0.188 12.6 8.8 6.1 150 9-5/16-10 3/4 x 30 x 3 108SSAH 20 4G 20 4 x 4 x 20 0.188 5.0 3.0 1.6 150 8-1/2-10 3/4 x 30 x 3 100SSAH 20 5G 20 5 x 5 x 20 0.188 9.9 6.6 4.2 175 9-5/16-10 3/4 x 30 x 3 117
Pole DataShaft Bolt Bolt Base WarehouseBase circle projection square Anchor Bolt Template size A B C description number
4"C 8-1/2–10" 3-1/2" 11-11/16" AB18-0 PJ500554"G 8-1/2–10" 3-1/2" 11-11/16" AB30-0 PJ500555" 9-5/16–10" 3-1/2" 11-11/16" AB30-0 PJ50056
NOTES:• Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)• Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°• Options: See page 202• Brackets: See page 203-204
INSTALLATION NOTES:
Installation requires grout to be packed under base toensure full contact with foundation. Factory-suppliedtemplates must be used when setting anchor bolts.American Electric Lighting will not accept claim forincorrect anchorage placement due to failure to useAmerican Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrappingmust be removed immediately upon delivery toprevent finish damage.
Ordering Information: See page 191(Note: Poles are available only in U.S.)
SSAHAnchor Base PolesSquare Straight Aluminum, Hinged
197Product Guide
P R O D U C T O V E R V I E W
FeaturesShaft – Weldable grade A500 or A513 carbon steel tubing with minimumyield of 46,000 or 42,000 psi. Uniform wall thickness of .120". Shafts areone-piece construction with a full length longitudinal, high frequencyelectric resistance weld. The round, straight tube is uniform in cross-section down length of shaft.
Anchor Base – Fabricated from carbon steel plate (ASTM A-36). 3/4"thickness. Base plate and shaft are circumferentially welded at both topand bottom to provide maximum strength at area of critical stress.
Anchor Bolts – Top 12" is fully galvanized per ASTM A-153. Made ofcarbon steel bar with minimum-yield strength of 55,000 psi.
Grounding – Nut holder located immediately inside handhole isprovided with 1/2”-13 UNC ground bolt and nut.
Handhole – Nominal 2.5" x 5" handhole is located 18" above base.Cover and attachment hardware provided.
Hardware – Fasteners are high-strength galvanized or zinc-plated orstainless steel.
Top Cap – Removable plastic top cap is provided for drill mount poles.
Finish – Dark bronze polyester powder paint (DDB) standard; optionalpolyester powder paint finishes available.
Base Cover – Full-base cover finished to match pole.
Intended UseFor 8’ to 30’ mounting height.
RSSAnchor Base Poles
Round Straight Steel
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall Bolt Bolt Approx.Catalog mount. Shaft Size Thick. 80 Max. 90 Max. 100 Max. Circle Size ship wt.Number ht. (ft.) (in. x in. x ft.) (in.) mph wt. mph wt. mph wt. (in.) (in. x in. x in.) (lbs.)
RSS 8 4-5B 8 4.5 x 8.0 0.120 24.7 630 19.7 495 16.0 430 8 3/4 x 18 x 3 55RSS 8 4-5B 8 4.5 x 8.0 0.120 24.5 615 19.5 490 15.8 395 8 3/4 x 18 x 3 55RSS 10 3B 10 3.0 x 10.0 0.120 10 250 7.7 190 6.0 175 8 3/4 x 18 x 3 55RSS 10 4B 10 4.0 x 10.0 0.120 19.1 480 15.0 375 12.2 305 8 3/4 x 18 x 3 70RSS 10 4-5B 10 4.5 x 10.0 0.120 24.5 615 19.5 490 15.8 395 8 3/4 x 18 x 3 75RSS 12 3B 12 3.0 x 12.0 0.120 7.7 195 5.8 145 4.4 130 8 3/4 x 18 x 3 60RSS 12 4B 12 4.0 x 12.0 0.120 15.0 390 11.8 300 9.5 240 8 3/4 x 18 x 3 80RSS 12 4-5B 12 4.5 x 12.0 0.120 19.8 495 15.7 395 12.7 320 8 3/4 x 18 x 3 85RSS 14 3B 14 3.0 x 14.0 0.120 6.0 175 4.4 130 3.3 90 8 3/4 x 18 x 3 70RSS 14 4B 14 4.0 x 14.0 0.120 12.2 305 9.4 250 7.6 195 8 3/4 x 18 x 3 90RSS 14 4-5B 14 4.5 x 14.0 0.120 16.2 405 12.8 320 10.3 260 8 3/4 x 18 x 3 95RSS 15 4-5B 15 4.5 x 15.0 0.120 12.0 300 9.5 250 7.5 200 8 3/4 x 18 x 3 96RSS 16 3B 16 3.0 x 16.0 0.120 4.6 125 3.2 100 2.3 60 8 3/4 x 18 x 3 80RSS 16 4B 16 4.0 x 16.0 0.120 9.6 250 7.4 185 5.9 150 8 3/4 x 18 x 3 100RSS 16 4-5B 16 4.5 x 16.0 0.120 13.1 330 10.2 265 8.2 205 8 3/4 x 18 x 3 105RSS 18 3B 18 3.0 x 18.0 0.120 3.4 90 2.3 60 1.4 70 8 3/4 x 18 x 3 90RSS 18 4B 18 4.0 x 18.0 0.120 7.6 190 5.7 180 4.5 130 8 3/4 x 18 x 3 110RSS 18 4-5B 18 4.5 x 18.0 0.120 10.5 265 8.2 210 6.5 165 8 3/4 x 18 x 3 115RSS 20 3B 20 3.0 x 20.0 0.120 2.4 100 1.4 75 — — 8 3/4 x 18 x 3 100RSS 20 4B 20 4.0 x 20.0 0.120 6.0 150 4.45 150 3.45 125 8 3/4 x 18 x 3 120RSS 20 4-5B 20 4.5 x 20.0 0.120 8.5 215 6.6 165 5.2 130 8 3/4 x 18 x 3 130RSS 20 5B 20 5.0 x 20.0 0.120 11.75 300 9.1 230 7.25 180 8 3/4 x 18 x 3 145RSS 22 4-5B 22 4.5 x 22.0 0.120 6.0 150 4.5 125 3.75 100 8 3/4 x 18 x 3 134RSS 25 4B 25 4.0 x 25.0 0.120 2.85 100 1.95 75 1.35 75 8 3/4 x 18 x 3 145RSS 25 4-5B 25 4.0 x 25.0 0.120 4.8 130 3.6 90 2.7 90 8 3/4 x 18 x 3 145RSS 25 5B 25 5.0 x 25.0 0.120 7.25 180 5.5 150 4.25 150 8 3/4 x 18 x 3 180RSS 30 4-5B 30 4.5 x 30.0 0.120 2.3 80 1.5 75 1.0 60 8 3/4 x 18 x 3 185RSS 30 5B 30 5.0 x 30.0 0.120 4.2 150 3 125 2.25 100 8 3/4 x 18 x 3 210
NOTES:• Mounting Arrangement: (PT) Open Top (T20) 2-3/8" O.D. (2" NPS)• Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
Pole DataShaft Bolt Bolt Base WarehouseBase circle projection square Anchor Bolt Templatesize A B C description number
3 8" 3-1/4" x 3-1/2" 8" AB18-0 PJ500414" 8" 3-1/4" x 3-1/2" 8" AB18-0 PJ50041
4-1/2" 8" 3-1/4" x 3-1/2" 8" AB18-0 PJ500415" 8" 3-1/4" x 3-1/2" 8" AB18-0 PJ50041
Ordering Information: See page 191 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Installation requires grout to be packed under base to ensure full contactwith foundation. Factory-supplied templates must be used when settinganchor bolts. American Electric Lighting will not accept claim for incorrectanchorage placement due to failure to use American Electric Lightingfactory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must be removedimmediately upon delivery to prevent finish damage.
Nut Holder
Handhole Cover
3 Options: see page 2024 Brackets: See page 203-204
P R O D U C T O V E R V I E W
198 Product Guide For more information please visit our website:www.americanelectriclighting.com
RTSAnchor Base PolesRound Tapered Steel
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall Bolt Bolt Approx. Catalog mount. Shaft Size Thick. 80 Max. 90 Max. 100 Max. Circle Size ship wt. Number ht. (ft.) (in. x in. x ft.) (in.) Gauge mph wt. mph wt. mph wt. (in.) in. x in. x in.) (lbs.)
RTS 20 5-9B 20 5.9 x 3.1 x 20 0.125 11 19.3 482 15.1 377 12.2 305 9.0 1 x 36 x 4 140RTS 20 6-5B 20 6.5 x 3.7 x 20 0.125 11 24.2 605 19.3 482 15.6 390 9.5 1 x 36 x 4 160RTS 25 5-9B 25 5.9 x 2.4 x 25 0.125 11 12.5 312 9.9 247 8 200 9.0 1 x 36 x 4 155RTS 25 7-0B 25 7.0 x 3.5 x 25 0.125 11 20.3 507 16.2 405 13.1 327 10.0 1 x 36 x 4 200RTS 25 7-0F 25 7.0 x 3.5 x 25 0.188 7 28.5 760 24.0 625 19.8 495 10.0 1 x 36 x 4 280RTS 30 6-6B 30 6.6 x 2.4 x 30 0.125 11 11.7 292 9.3 232 7.5 187 9.5 1 x 36 x 4 200RTS 30 8-0B 30 8.0 x 3.8 x 30 0.125 11 18.9 473 14.9 373 12 300 11.0 1 x 36 x 4 265RTS 30 8-0F 30 8.0 x 3.8 x 30 0.188 7 27.5 838 27.0 675 22.0 550 11.0 1-1/4 x 42 x 6 380RTS 35 7-3B 35 7.3 x 2.4 x 35 0.125 11 11.2 280 8.9 222 7.1 177 10.5 1 x 36 x 4 250RTS 35 8-5B 35 8.5 x 3.6 x 35 0.125 11 18.9 472 15.1 377 12.2 305 11.5 1 x 36 x 4 315RTS 35 9-5B 35 9.5 x 4.6 x 35 0.125 11 23.2 580 18.2 455 14.5 363 13.0 1 x 36 x 4 370RTS 39 7-8B 39 7.8 x 2.4 x 39 0.125 11 10.7 267 8.5 212 6.6 165 11.0 1 x 36 x 4 285RTS 39 9-0B 39 9.0 x 3.6 x 39 0.125 11 17.2 430 13.5 338 10.8 270 12.5 1 x 36 x 4 355RTS 39 9-0F 39 9.0 x 3.6 x 39 0.188 7 28.5 715 23.0 575 19.0 475 12.5 1-1/4 x 42 x 6 515RTS 45 10-0B 45 10.0 x 3.7 x 45 0.125 11 17.4 435 13.5 338 10.6 265 13.5 1 x 36 x 4 450RTS 45 10-0F 45 10.0 x 3.7 x 45 0.188 7 28.5 715 23.0 575 19.0 475 13.5 1-1/4 x 42 x 6 650RTS 50 10-0B 50 10.0 x 3.0 x 50 0.125 11 13.2 330 10.6 265 8.3 208 13.5 1 x 36 x 4 475RTS 50 10-0F 50 10.0 x 3.0 x 50 0.188 7 20.5 512 16.5 412 13.6 340 13.5 1-1/4 x 42 x 6 680
NOTES:• Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)• Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°• Options: See page 202• Brackets: See page 203-204
FeaturesShaft – Minimum weldable-grade (ASTM A-595 Grade A), hot-rolled,commercial-quality carbon steel tubing with minimum yield of 55,000psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793").Shafts are constructed with full-length, longitudinal, high-frequencyresistance weld. Round in cross-section, having uniform taper ofapproximately .14" per foot.
Anchor Base – Fabricated from hot-rolled carbon steel plate thatconforms to ASTM A36.
Handhole – Reinforced handhole rim having nominal dimensions of3"x5" for shafts less than 6.25" base diameter and 4"x6.5" for all othershafts. Steel cover with attachment screws included. Handhole islocated 18" above base.
Grounding – Nut holder located immediately inside handhole isprovided with 1/2”-13 UNC ground bolt and nut.
Anchor Bolts – Fabricated from commercial-quality hot-rolled carbonsteel with minimum yield strength of 55,000 psi. Bolts have an "L" bendon one end.
Hardware – Fasteners are high-strength galvanized or zinc-plated orstainless steel.
Top Cap – Removable top cap provided with all drill-mount poles.
Finish – Dark bronze polyester powder finish (DDB) standard; otherarchitectural colors available.
Bolt Cover – Bolt covers are zinc diecast and fasten to shaft by a .25”stainless steel, self tapping hexhead screw. Full base cover availableas option.
Intended UseFor 20’ to 50’ mounting height.
INSTALLATION NOTES:
Installation requires grout to be packedunder base to ensure full contact withfoundation. Factory-supplied templatesmust be used when setting anchorbolts. American Electric Lighting willnot accept claim for incorrectanchorage placement due to failure touse American Electric Lighting factorytemplates.
Do not erect poles without havingfixtures installed.
If poles are stored outside, allprotective wrapping must be removedimmediately upon delivery to preventfinish damage.
Ordering Information: See page 191(Note: Poles are available onlyin U.S.)
Pole Data
Shaft Bolt Bolt Base Warehouse TemplateBase Circle Projection Square Bolt Numbersize A B C description
5.9" B 9" 3-1/2"–4-1/4" 10" AB36-0 PJ500756.5" B 9.5" 3-1/2"–4-1/4" 10-1/2" AB36-0 PJ500747.0" B 10" 3-1/2"–4-1/4" 10-7/8" AB36-0 PJ500777.0" F 10" 3-3/4"–4-1/2" 10-7/8" AB36-0 PJ500766.6" B 9.5" 3-1/2"–4-1/4" 10-1/2" AB36-0 PJ500788.0" B 11" 3-1/2"–4-1/4" 11-1/2" AB36-0 PJ500798.0" F 11" 4-1/2–5-1/4" 11-1/2" N/A PJ500807.3" B 10.5" 3-1/2"–4-1/4" 11-1/4" AB36-0 PJ500818.5" B 11.5" 3-3/4"–4-1/2" 12" AB36-0 PJ500829.5" B 13" 3-3/4"–4-1/2" 13" AB36-0 PJ500837.8" B 11" 3-3/4"–4-1/2" 11-1/2" AB36-0 PJ500849.0" B 12.5" 3-3/4"–4-1/2" 12-3/8" AB36-0 PJ500859.0" F 12.5" 4-1/2–5-1/4" 12-3/8" N/A PJ5008610.0" B 13.5" 3-3/4"–4-1/2" 14" AB36-0 PJ5008710.0" F 13.5" 4-1/2–5-1/4" 14" N/A PJ50088
199Product Guide
P R O D U C T O V E R V I E W
SSSAnchor Base Poles
Square Straight Steel
FeaturesShaft – Weldable grade, hot-rolled, commercial-quality carbon steeltubing with a minimum yield of 55,000 psi (11-gauge), 50,000 psi (7-gauge). Uniform wall thickness of .125" or .188". Shaft is one-piece witha full-length, longitudinal, high frequency electric resistance weld.Uniformly square in cross-section with flat sides, small corner radiiand excellent torsional qualities. Available shaft widths are 4, 5 and 6inches.
Anchor Base – Fabricated from hot-rolled carbon steel plate thatmeets or exceeds a minimum-yield strength of 36,000 psi. The anchorbase is provided with slotted holes.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4" or 1"diameter steel rod having a minimum-yield strength of 55,000 psi.
Grounding – Nut holder located immediately inside handhole rim isprovided with a 1/2" x13 UNC ground bolt and nut (by others).
Handhole – 1/2”-13, Reinforced handhole rim having nominaldimensions of 3"x5" for all shafts. Includes steel cover withattachment screws.
Hardware – Fasteners are high-strength, galvanized or zinc-plated orstainless steel.
Top Cap – Removable top cap is provided for drill mount poles.
Finish – Dark bronze polyester powder paint (DDB) standard; optionalpolyester powder paint finishes available.
Base Cover – Full-base cover finished to match pole.
Intended UseFor 10’ to 39’ mounting height.
Ordering Information: See page 191 (Note: Poles are available only in U.S.)
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall Bolt Bolt Approx.
Catalog mount. Shaft Size Thick. 80 Max. 90 Max. 100 Max. Circle Size ship wt.
Number ht. (ft.) (in. x in. x ft.) (in.) Gauge mph wt. mph wt. mph wt. (in.) (in. x in. x in.) (lbs.)
SSS 10 4C 10 4.0 x 10.0 0.125 11 30.6 765 23.8 595 18.9 473 8–9 3/4 x 18 x 3 75SSS 12 4C 12 4.0 x 12.0 0.125 11 24.4 610 18.8 470 14.8 370 8–9 3/4 x 18 x 3 90SSS 14 4C 14 4.0 x 14.0 0.125 11 19.9 498 15.1 378 11.7 293 8–9 3/4 x 18 x 3 100SSS 16 4C 16 4.0 x 16.0 0.125 11 15.9 398 11.8 295 8.9 223 8–9 3/4 x 18 x 3 115SSS 18 4C 18 4.0 x 18.0 0.125 11 12.6 315 9.2 230 6.7 168 8–9 3/4 x 18 x 3 125SSS 20 4C 20 4.0 x 20.0 0.125 11 9.6 240 6.7 167 4.5 150 8–9 3/4 x 18 x 3 140SSS 20 4G 20 4.0 x 20.0 0.188 7 14.0 350 11.0 275 8.0 200 8–9 3/4 x 30 x 3 198SSS 20 5C 20 5.0 x 20.0 0.125 11 17.7 443 12.7 343 9.4 235 10–12 1 x 36 x 4 185SSS 20 5G 20 5.0 x 20.0 0.188 7 28.1 703 21.4 535 16.2 405 10–12 1 x 36 x 4 265SSS 25 4C 25 4.0 x 25.0 0.125 11 4.8 150 2.6 100 1.0 50 8–9 3/4 x 18 x 3 170SSS 25 4G 25 4.0 x 25.0 0.188 7 10.8 270 7.7 188 5.4 135 8–9 3/4 x 30 x 3 245SSS 25 5C 25 5.0 x 25.0 0.125 11 9.8 245 6.3 157 3.7 150 10–12 1 x 36 x 4 225SSS 25 5G 25 5.0 x 25.0 0.188 7 18.5 463 13.3 333 9.5 238 10–12 1 x 36 x 4 320SSS 30 4G 30 4.0 x 30.0 0.188 7 6.0 150 4.0 100 2.5 75 8–9 3/4 x 30 x 3 295SSS 30 5C 30 5.0 x 30.0 0.125 11 4.7 150 2.0 50 — — 10–12 1 x 36 x 4 265SSS 30 5G 30 5.0 x 30.0 0.188 7 10.7 267 6.7 167 3.9 100 10–12 1 x 36 x 4 380SSS 30 6G 30 6.0 x 30.0 0.188 7 19.0 475 13.2 330 9.0 225 11–13 1 x 36 x 4 520SSS 35 5G 35 5.0 x 35.0 0.188 7 5.9 150 2.5 100 — — 10–12 1 x 36 x 4 440SSS 35 6G 35 6.0 x 35.0 0.188 7 12.4 310 7.6 190 4.2 105 11–13 1 x 36 x 4 540SSS 39 6G 39 6.0 x 39.0 0.188 7 7.2 180 3.0 75 — — 11–13 1 x 36 x 4 605
Pole DataShaft Bolt Bolt Base WarehouseBase circle projection square Anchor Bolt Templatesize A B C description number
4"C 8-1/2" 2-3/4"–4" 8" AB18-0 PJ500044"G 8-1/2" 2-3/4"–4" 8" AB30-0 PJ500045" 10"–12" 3-3/8"–4" 11" AB36-0 PJ500106" 11"–13" 3-3/8"–4" 12-1/2" AB36-0 PJ50011
NOTES:• Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. • (2" NPS)• Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°• Options: See page 202• Brackets: See page 203-204
INSTALLATION NOTES:
Installation requires grout to be packedunder base to ensure full contact withfoundation. Factory-supplied templatesmust be used when setting anchorbolts. American Electric Lighting willnot accept claim for incorrectanchorage placement due to failure touse American Electric Lightingfactory templates.
Do not erect poles without havingfixtures installed.
If poles are stored outside, allprotective wrapping must be removedimmediately upon delivery to preventfinish damage.
200 Product Guide
P R O D U C T O V E R V I E W
For more information please visit our website:www.americanelectriclighting.com
STSAnchor Base PolesSquare Tapered Steel
Pole DataShaft Bolt Bolt Base Warehouse TemplateBase Circle Projection Square Anchor Bolt Numbersize A B C description
5.2" B 10-3/4" 3-1/2–4-1/4" 10-3/4" AB36-0 PJ500955.5" F 11" 3-3/4"–4-1/2" 11" AB36-0 PJ500966.0" B 12" 3-1/2–4-1/4" 11-1/2" AB36-0 PJ500976.4" F 12-1/2" 4"–4-3/4" 11-7/8" AB36-0 PJ500986.4" B 12-1/2" 3-1/2–4-1/4" 11-7/8" AB36-0 PJ500996.8" B 13" 3-1/2–4-1/4" 12-1/4" AB36-0 PJ501017.1" F 13-1/2" 4-1/4"–5" 12-5/8" AB36-0 PJ501027.1" B 13-1/2" 3-1/2–4-1/4" 12-5/8" AB36-0 PJ501037.8" F 14-1/2" 4"–4-3/4" 13-3/8" AB36-0 PJ501058.7" F 15-3/4" 4-3/4"–5-1/2" 14-1/4" AB42-0 PJ501068.8" F 16" 4-1/2–5-1/4" 15-1/2" AB42-0 PJ50107
NOTES:1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°3 Options: See page 2024 Brackets: See page 203-204
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Wall Bolt Bolt Approx. Catalog mount. Shaft Size Thick. 80 Max. 90 Max. 100 Max. Circle Size ship wt. Number ht. (ft.) (in. x in. x ft.) (in.) Gauge mph wt. mph wt. mph wt. (in.) (in. x in. x in.) (lbs.)
STS 20 5-2B 20 5.25 x 3.05 x 20 0.125 11 18.0 452 13.8 345 10.7 268 10-3/4 1 x 36 x 4 155STS 20 5-5F 20 5.50 x 3.30 x 20 0.188 7 30.5 764 24.0 602 19.0 477 11 1 x 36 x 4 235STS 25 6-0B 25 6.00 x 3.25 x 25 0.125 11 16.8 422 12.6 315 9.5 238 12 1 x 36 x 4 205STS 25 6-4F 25 6.41 x 3.66 x 25 0.188 7 28.5 713 22.5 563 18.2 455 12-1/2 1 x 36 x 4 310STS 30 6-4B 30 6.41 x 3.11 x 30 0.125 11 13.6 340 9.8 245 7.0 175 12-1/2 1 x 36 x 4 260STS 30 6-4F 30 6.41 x 3.11 x 30 0.188 7 23.6 590 17.9 448 13.7 343 12-1/2 1 x 36 x 4 375STS 35 6-8B 35 6.81 x 2.96 x 35 0.125 11 10.7 269 7.3 184 4.8 120 13 1 x 36 x 4 305STS 35 7-1F 35 7.13 x 3.28 x 35 0.188 7 23.4 585 17.4 435 13.0 325 13-1/2 1 x 36 x 4 475STS 39 7-1B 39 7.18 x 2.92 x 39 0.125 11 8.6 215 5.4 135 3.0 75 13-1/2 1 x 36 x 4 345STS 39 7-1F 39 7.13 x 2.87 x 39 0.188 7 19.3 483 14.2 355 10.4 260 13-1/2 1 x 36 x 4 500STS 45 7-8F 45 7.88 x 2.93 x 45 0.188 7 16.0 400 11.1 278 7.4 187 14-1/2 1 x 36 x 4 620STS 45 8-7F 45 8.75 x 3.80 x 45 0.188 7 23.5 588 16.6 415 11.4 287 15-3/4 1-1/4 x 42 x 6 730STS 50 8-8F 50 8.81 x 3.31 x 50 0.188 7 19.4 485 13.2 332 8.7 218 16 1-1/4 x42 x 6 780
FeaturesShaft – Weldable-grade (ASTM A595 Grade A) hot-rolled commercial-quality carbon steel tubing with minimum yield of 55,000 psi. Uniformwall thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts areconstructed with full-length longitudinal high-frequency resistanceweld and are square in cross-section, having flat sides, radiusedcorners and a uniform taper of approximately .11" per foot.
Anchor Base – Fabricated from hot-rolled carbon steel plate thatconforms with ASTM A36.
Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbonsteel with minimum-yield strength of 55,000 psi. Bolts have an "L" bendon one end.
Grounding – Nut holder located immediately inside handhole rim istapped for a 1/2" – 13 UNC ground bolt and nut (by others).
Handhole – Reinforced handhole rim having nominal dimensions of3"x5" for shafts less than 6.375" square and 4"x6.5" for all other shafts.Steel cover with attachment screws included. Handhole is located 18"above base.
Hardware – Fasteners are high-strength galvanized or zinc-plated orstainless steel.
Top Cap – Removable top cap provided with all drill-mount poles.
Finish – Must specify finish.
Base Cover – Full-base cover finished to match pole.
Intended UseFor 20’ to 50’ mounting height.
INSTALLATION NOTES:
Installation requires grout to bepacked under base to ensure fullcontact with foundation. Factory-supplied templates must be usedwhen setting anchor bolts. AmericanElectric Lighting will not accept claimfor incorrect anchorage placementdue to failure to use American ElectricLighting factory templates.
Do not erect poles without havingfixtures installed.
If poles are stored outside, allprotective wrapping must be removedimmediately upon delivery to preventfinish damage.
Ordering Information: See page 191 (Note: Poles are available onlyin U.S.)
201Product Guide
P R O D U C T O V E R V I E W
FeaturesShaft – Weldable-grade, hot-rolled, commercial-quality carbon steelhaving a guaranteed minimum yield strength of 55,000 psi and issupplied in 11-gauge (.1196") or 7-gauge (.1793") nominal thickness.Pole is one-piece construction with full-length, longitudinal, high-frequency, electric-resistance weld. Shaft is square in cross sectionhaving flat sides, radiused corners, and uniform taper ofapproximately 11” per foot (4-inch square poles are not tapered).
Hinge – The hinge includes a stainless steel hinge pin. A flexiblewiring guide is provided, passing through the hinge area for wiringprotection. Hinge is external.
Anchor Base – Fabricated from hot-rolled carbon steel plate thatconforms with ASTM A36.
Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbonsteel with minimum-yield strength of 55,000 psi. Bolts have an "L" bendon one end.
Grounding – Nut holder located immediately inside handhole rim istapped for a 1/2" – 13 UNC ground bolt and nut (provided by others).
Handhole – Reinforced handhole rim having nominal dimensions of 3"x 5" for shafts less than 6.375" square and 4" x 6.5" for all other shafts.Steel cover with attachment screws included. Handhole is located 18"above base on hinge side.
Hardware – Fasteners are high-strength, galvanized or zinc-plated orstainless steel.
Top Cap – Removable top cap provided with all drill-mount poles.
Finish – Dark bronze polyester powder finish (DDB) standard; otherarchitectural colors available.
Base Cover – Full-base cover is provided.
Intended UseFor 20’ to 39’ mounting height.
STSHAnchor Base Poles
Square Tapered Steel Hinge
Technical InformationEPA (ft2) with 1.3 gust
Catalog Nom. Pole Wall Bolt Bolt Approx. Number mount. Shaft Size Thick. 80 Max. 90 Max. 100 Max. Circle Size ship wt
ht. (ft.) (in. x in. x ft.) (in.) Gauge mph wt. mph wt. mph wt. (in.) (in. x in. x in.) (lbs)
STSH 20 4F 20 4 x 4 x 20 0.188 7 11.6 217 8.5 217 6.2 217 8-1/2-10 3/4 x 18 x 3 300STSH 25 4B 25 4 x 4 x 25 0.188 7 7.1 160 4.8 160 3.1 160 8-1/2-10 3/4 x 18 x 3 370STSH 25 6-4B 25 6.41 x 3.63 x 25 0.125 11 18.0 254 13.0 254 9.3 254 12-1/2 1 x 36 x 4 355STSH 30 4F 30 4 x 4 x 30 0.188 7 4.0 120 2.1 120 0.8 120 8-1/2-10 3/4 x 18 x 3 435STSH 30 6-4B 30 6.41 x 3.08 x 30 0.125 11 12.5 230 8.3 230 5.1 230 12-1/2 1 x 36 x 4 440STSH 35 7-1B 35 7.18 x 2.88 x 35 0.125 11 7.1 160 3.2 160 — — 13-1/2 1 x 36 x 4 540STSH 35 7-1F 35 7.13 x 2.87 x 35 0.188 7 22.0 155 16.9 155 12.1 155 13-1/2 1 x 36 x 4 700STSH 39 7-1F 39 7.13 x 2.87 x 39 0.188 7 19.5 110 13.5 110 9.2 110 13-1/2 1 x 36 x 4 740
NOTES:• Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)• Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°• Options: See page 202• Brackets: See page 203-204
Pole DataShaft Bolt Bolt Base Warehouse TemplateBase Circle Projection Square Anchor Bolt Numbersize A B C description
4.0" F 8-1/2–10" 3-1/2–4-1/4" 9-3/4" AB18-0 PJ500916.4" B 12-1/2" 3-3/4"–4-1/2" 11-7/8" AB36-0 PJ500927.1" F 13-1/2" 4"–4-3/4" 12-5/8" AB36-0 PJ500937.1" B 13-1/2" 3-1/2–4-1/4" 12-5/8" AB36-0 PJ50094
Winch OrderingFamily Winch Shaft size Order nomenclature
STSH WCH 4F or 4B STSHWCH 4F6-4B STSHWCH 6-4B7-1B STSHWCH 7-1B7-1F STSHWCH 7-1F
Ordering Information: See page 191 (Note: Poles are available only in U.S.) INSTALLATION NOTES:
Installation requires grout to be packed underbase to ensure full contact with foundation.Factory-supplied templates must be usedwhen setting anchor bolts. American ElectricLighting will not accept claim for incorrectanchorage placement due to failure to useAmerican Electric Lighting factory templates.
Do not erect poles without having fixturesinstalled.
If poles are stored outside, all protectivewrapping must be removed immediately upondelivery to prevent finish damage.
External Hinge Detail
Winch Detail (accessory)
202 Product Guide For more information please visit our website:www.americanelectriclighting.com
P R O D U C T O V E R V I E W
Pole Options
Tenon O.D. One Two@180° Two@90° Three@120° Three@90° Four@90°
2-3/8" T20-190 T20-280 T20-290 T20-320 T20-390 T20-4902-7/8" T25-190 T25-280 T25-290 T25-320 T25-390 T25-490
4" T35-190 T35-280 T35-290 T35-320 T35-390 T35-490
Tenon Mounting Slipfitters (Order separately)
Number of fixtures
SBC4 SSS 4" 8.75" x 5.8"SBC5 SSS 5" 11.44" x 6.4"SBC6 SSS 6" 13.5" x 4"
Cat. No. A B C D Wt. (lbs.)
SBT-4S1 2-3/8" 3" 13-3/4" 5" 7SBT-5S1 2-3/8" 4" 13-3/4" 5" 8SBT-6S2 2-3/8" 5" 13-3/4" 5" 17
EPA WeightOption (sq. ft.) (lbs.)
H1-18A Aluminum .43 7H1-18S Steel .50 11HI-18F Fiberglass .45 8HI-18C Concrete .55 9
Option Description
FDL Festoon Duplex Outlet, Less Electric
Field InstalledVibration Dampener
Handhole Opening
Foundation
Base CoversTwo-piece, full-base cover. Four fasteners provided to secure pieces together.Finished to match pole. Shipped separately. Standard with steel poles only.
Festoon OutletsProvision provided for mounting duplex outlet. When ordering, specify locationin height and feet above base of pole and orientation from the handhole.
Handheld Cover PlatesSSS HHC: For all SSS poles
All other poles order as handhole cover for full poledescription. Also specify if pole is existing.
Nut CoversFour nut covers are standard for RSA, RTA and RTSpoles only.
Tamperproof ScrewsTamperproof (TP): Order as TP. Tamperproof screwsprovided with base cover.
Bolt-on Tenon Square Steel PolesTenon Dimensions.
Horizontal Arm BracketSingle or twin side-mounted horizontal arm brackets for additionalluminaires. Made from 2 3/8," pipe. Upright is 18" from pole; special armlengths may be available upon request. Arms are rated for luminaires up to4.5 sq. ft. EPA and 100 lbs. per arm. When ordering, specify location in heightand feet above base of pole and orientation from the handhole.
Note: SSS and SSA arm attachment is slightlydifferent from RTA. Arm modifications locatedon pole to accept arms. Arms shipped asseparate item.
VD - Vibration DamperIt has been found that steady 10-30 mph windssometimes induce second or higher mode of vibrationin lighting poles. Second mode vibration ischaracterized by the maximum periodic motionoccurring at approximately the mid-height of the pole.This type of vibration can result in failure of the poleand/or luminaire. There is no method of predictingdestructive light pole vibration. Vibration damperswhich alleviate this condition are available. Shippedinstalled.
Note: FVD - Field installable vibrator damper available uponrequest. Consult factory.
Notes:
1 Stocked in distribution centers.2 Ordered on a drop-ship basis.
SSS
For full-base cover on other poles, must order FBC. When ordering separately,specify full pole nomenclature; i.e., FBC for RTA 25 7E. Also specify if pole isexisting.
Anchor BoltsAvailable in various sizes for use with American Electric Lighting poles. Setincludes hex nuts and washers. Anchor bolt is partially galvanized for exposedthreads per ASTM-A153. Bolts have minimum-yield strength rating of 55,000psi, AASHTO M314 GR55. See individualpole catalog pages for anchor boltsizes and description.
CPL12 1/2" threaded coupling NPL12 1/2" threaded nippleCPL34 3/4" threaded coupling NPL34 3/4" threaded nippleCPL1 1" threaded coupling NPL1 1" threaded nipple"
Couplings & NipplesThreaded couplings and/or nipples can be factory installed. When ordering,specify location in height and side of pole (ex: A, B, C, D).
Option Pole (square) (depth)Dimension Dimension
203Product Guide
P R O D U C T O V E R V I E W
Aluminum Mounting BracketsBullhorns and Spokes - order as separate items
Projected area is for bracket only. Bracket projected area is added toluminaire projected area to get total effective projected area (EPA). Allbrackets have a maximum luminaire rating per tenon of 4.5 sq. ft. projectedarea and 100 lbs. at a wind velocity of 100 mph (luminaire drag coefficient =1.0).
FinishNatural aluminum. Optional painted finishes available. Plastic cap supplied.
Round PoleBrackets mount to T25 tenon 2-7/8” O.D., or pole top that is 2-7/8” O.D. Heavyduty version mounts to T35 tenon 4” O.D.
Brackets for Aluminum Poles Only
Brackets for Aluminum Poles OnlySquare PoleBrackets flush mount on 4", 5" and 6" square poles. For use with internalsleeve, plain open-top poles, American Electric Lighting poles only. Must beordered with pole to ensure proper fit.
6"
Catalog EPA WeightNumber (sq. ft.) (lbs.)
RBA28 1.2 7.0RBA32 1.7 14.3RBA38 1.9 10.5RBA48 2.7 14.5RBA49 2.2 17.5
Catalog EPA WeightNumber (sq. ft.) (lbs.)
RBA28 HD 1.3 8.4RBA32 HD 1.7 12.7RBA38 HD 2.0 11.9RBA48 HD 2.8 16.2RBA49 HD 2.2 15.8
Catalog EPA WeightNumber (sq. ft.) (lbs.)
SBA28 0.90 12SBA38 1.50 17SBA48 2.25 22SBA49 1.7 22
RBA28 RBA32
RBA48
RBA49
SBA38
SBA48 SBA28
SBA49
RBA38
204 Product Guide
P R O D U C T O V E R V I E W
For more information please visit our website:www.americanelectriclighting.com
Projected area is for bracket only. Bracket projected area is added toluminaire projected area to get total effective projected area (EPA).All brackets have a maximum luminaire rating per tenon of 4.5 sq. ft.projected area and 100 lbs. at a wind velocity of 100 mph (luminairedrag coefficient = 1.0).
FinishDark bronze, standard. Other colors available (consult local American ElectricLighting representative). Plastic cap supplied.
FinishDark bronze, standard.
Brackets for Steel Poles Only
Brackets for Square Steel Poles OnlyRequires T20 (2-3/8" max OD) tenon on pole for mounting
Catalog EPA WeightNumber (sq. ft.) (lbs.)
BS28 1.0 21.0BS32 1.3 34.0BS38 1.6 32.0BS48 2.3 44.0BS49 1.6 44.0
Catalog EPA WeightNumber (sq. ft.) (lbs.)
BS28 HD 1.3 28.0BS32 HD 2.0 38.0BS38 HD 2.2 38.0BS48 HD 3.4 47.0BS49 HD 2.8 46.0
Catalog EPA WeightNumber (sq. ft.) (lbs.)
SBS 28 1.1 30.0SBS 38 1.7 42.0SBS 49 2.1 45.0
Steel Mounting BracketsBullhorns and Spokes - order as separate items
SBS28
BS48 BS49
BS32BS38
BS28
Standard HubO.D. 2 7/8” - I.D. 2 1/2”Requires T20 Tenon (min. 5” tall)
Heavy Duty HubO.D. 4 1/2” - I.D. 4”Requires T35 Tenon (min. 6” tall)
SBS38 SBS49
205Product Guide
P R O D U C T O V E R V I E W
RTFAnchor Base Poles
Round Tapered Fiberglass
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Bolt Bolt Approx.Catalog mount. Shaft Size 80 90 100 Max. Circle Size ship wt.Number ht. (ft.) (in. x in. x ft.) mph mph mph wt. (in.) (in. x in. x in.) (lbs.)
RTF 20 7-3X 20 7.3 x 4.6 x 20 14.4 11.1 8.9 200 11-1/2 1 x 30 x 4 62RTF 25 7-3X 25 7.3 x 4.6 x 25 9.6 7.3 5.7 200 11-1/2 1 x 30 x 4 75RTF 30 8-4X 30 8.4 x 4.6 x 30 11.2 8.5 6.7 100 11-1/2 1 x 30 x 4 106RTF 30 8-5X 30 8.5 x 4.8 x 30 15.6 12.0 9.5 200 11-1/2 1 x 30 x 4 140RTF 30 10-5X 30 10.5 x 6.6 x 30 28.7 22.4 17.4 300 14-1/2 1 x 30 x 4 202RTF 35 8-4X 35 8.4 x 4.6 x 35 5.5 3.8 2.7 100 11-1/2 1 x 30 x 4 125RTF 35 8-5X 35 8.5 x 4.8 x 35 8.5 6.2 4.7 200 11-1/2 1 x 30 x 4 161RTF 35 11-2X 35 11.2 x 6.6 x 35 21.8 16.6 12.5 300 15 1-1/4 x 36 x 6 248RTF 40 11-7X 40 11.7 x 6.2 x 40 6.4 4.3 2.4 165 15-1/2 1-1/4 x 36 x 6 165RTF 40 11-8X 40 11.8 x 6.4 x 40 12.2 8.8 6.0 300 15-1/2 1-1/4 x 36 x 6 227RTF 40 12X 40 12.0 x 6.9 x 40 25.8 19.3 14.3 300 15-1/2 1-1/4 x 36 x 6 317RTF 45 11-7X 45 11.7 x 6.2 x 45 3.9 2.0 0.6 300 15-1/2 1-1/4 x 36 x 6 183RTF 45 11-9X 45 11.9 x 6.6 x 45 15.2 10.9 7.6 300 15-1/2 1-1/4 x 36 x 6 295
Pole DataShaft Bolt Bolt Base TemplateBase Circle Projection Square Numbersize A B C
7.3" 11.5" 4" 11" PJ501148.4" 11.5" 4" 11" PJ501158.5" 11.5" 4" 11" PJ5011610.5" 14.5" 4" 13.3" PJ5011711.2 15" 4" 13.5" PJ5011811.7" 15.5" 4" 14" PJ5011911.8" 15.5" 4" 14" PJ5012011.9" 15.5" 4" 14" PJ5012112.0" 15.5" 4" 14" PJ50122
ConstructionShaft – “E” type fiberglass reinforced composite shaft incorporatingpigmented, UV inhibiting, thermosetting polyester resin and a smoothsurface finished with a polyurethane surface coat providing aminimum 1.5 mil dry film thickness.
Anchor Base – Heavy-duty, A356-T6 aluminum base casting ispermanently bonded to the outside of the fiberglass shaft.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 1” or1-1/4” diameter steel rod having a minimum-yield strength of 55,000 psi.
Handhole – An oval, non-metallic, 2 1/2"x5" handhole secured with avandal resistant fastener.
Hardware – Fasteners are high-strength galvanized or zinc-plated orstainless steel.
Top Cap – Removable top cap provided with all drill-mount poles.
Finish – Ultraviolet resistant and pigmented approximately the samecolor as the final polyurethane coating. Must specify color.
Base Cover – Full base cover is optional and finished to match pole.
Intended UseFor 20’ to 45’ mounting height.
INSTALLATION NOTES:
Installation requires grout to be packed under base toensure full contact with foundation. Factory-suppliedtemplates must be used when setting anchor bolts.American Electric Lighting will not accept claim forincorrect anchorage placement due to failure to useAmerican Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping mustbe removed immediately upon delivery to prevent finishdamage.
Ordering Information: See page 191 (Note: Poles are available only in U.S.)
4”Bolt Projection
NOTES:1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°3 Options: See page 2024 Brackets: See page 203-204
P R O D U C T O V E R V I E W
206 Product Guide For more information please visit our website:www.americanelectriclighting.com
ConstructionShaft – “E” type fiberglass reinforced composite shaft incorporatingpigmented, UV inhibiting, thermosetting polyester resin and a smoothsurface finished with a polyurethane surface coat providing aminimum 1.5 mil dry film thickness.
Handhole – An oval, non-metallic, 2 1/2"x5" handhole secured with avandal-resistant fastener.
Hardware – Fasteners are high-strength galvanized or zinc-plated orstainless steel.
Top Cap – Removable top cap provided with all drill-mount poles.
Finish – Ultraviolet resistant and pigmented approximately the samecolor as the final polyurethane coating. Must specify color.
Intended UseFor direct burial, 14’ to 35’ mounting height.
RTFDBDirect Buried PolesRound Tapered Fiberglass
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Approx.Catalog mount. Shaft Size 80 90 100 Max. ship wt.Number ht. (ft.) (in. x in. x ft.) mph mph mph wt. (lbs.)
RTFDB 18 6X 14 6.0 x 4.1 x 18 14.0 10.4 7.9 150 34RTFDB 20 6-6X 16 6.6 x 4.1 x 20 10.0 7.4 5.5 100 38RTFDB 24 6-7X 20 6.7 x 4.1 x 24 8.2 5.8 4.1 150 46RTFDB 30 8-3X 25 8.3 x 4.4 x 30 6.2 4.7 3.6 100 71RTFDB 30 8-4X 25 8.4 x 4.6 x 30 14.5 11.2 8.9 200 98RTFDB 35 8-4X 30 8.4 x 4.6 x 35 10.5 8.0 6.2 200 116RTFDB 35 8-5X 30 8.5 x 4.9 x 35 14.8 11.4 9.0 300 153RTFDB 41 11-8X 35 11.8 x 6.4 x 41 14.3 10.8 7.8 300 218
Ordering Information: See page 191 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Do not erect poles without having fixturesinstalled.
If poles are stored outside, all protectivewrapping must be removed immediatelyupon delivery to prevent finish damage.
NOTES:1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°3 Options: See page 2024 Brackets: See page 203-204
207Product Guide
P R O D U C T O V E R V I E W
NOTES:1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°3 Options: See page 2024 Brackets: See page 203-204
SSFAnchor Base PolesSquare Straight Fiberglass
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Bolt Bolt Approx.Catalog mount. Shaft Size 80 90 100 Max. Circle Size ship wt.Number ht. (ft.) (in. x in. x ft.) mph mph mph wt. (in.) (in. x in. x in.) (lbs.)
SSF 6 4X 6 4 x 4 x 6 23.2 17.9 14.2 150 8 5/8 x 21 x 3 18SSF 8 4X 8 4 x 4 x 8 16.5 12.6 9.8 150 8 5/8 x 21 x 3 23SSF 10 4X 10 4 x 4 x 10 12.0 8.9 6.7 150 8 5/8 x 21 x 3 27SSF 12 4X 12 4 x 4 x 12 9.1 6.5 4.6 100 8 5/8 x 21 x 3 31SSF 14 4X 14 4 x 4 x 14 6.7 4.4 2.8 100 8 5/8 x 21 x 3 35SSF 16 4X 16 4 x 4 x 16 3.7 2.2 1.1 100 8 5/8 x 21 x 3 39SSF 20 4X 20 4 x 4 x 20 7.2 1.8 0.5 150 8 5/8 x 21 x 3 80SSF 20 5X 20 5 x 5 x 20 12.2 9.1 6.9 200 11 1 x 30 x 4 110SSF 25 4X 25 4 x 4 x 25 4.2 2.5 0.75 150 8 5/8 x 21 x 3 90SSF 25 5X 25 5 x 5 x 25 8.7 6.2 4.4 200 11 1 x 30 x 4 115SSF 30 5X 30 5 x 5 x 30 4.7 2.8 1.9 200 11 1 x 30 x 4 120SSF 30 5XHD 30 5 x 5 x 30 8.6 5.1 2.6 200 10-12 1 x 30 x 4 164
Pole DataShaft Bolt Bolt Base Anchor TemplateBase Circle Projection Square Bolt Numbersize A B C description
4" 8" 3" 7.4" ABSSF-4 PJ501235" 11" 4" 11.1" ABSSF-5 PJ50124
FeaturesShaft – Constructed by the pultrusion process from thermosettingpolyester resin and contains a minimum of 65 percent "E" typefiberglass by weight. The fiberglass strands traverse the length of thepole.
Anchor Base – Heavy-duty, A356-T6 aluminum base casting ispermanently bonded to the outside of the fiberglass shaft.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 5/8" or 1"diameter steel rod having a minimum-yield strength of 55,000 psi.
Handhole – An oval, non-metallic, 2 1/2" x 5" handhole secured with avandal-resistant, stainless steel 1/4" socket head screw.
Hardware – Fasteners are high-strength galvanized or zinc-plated orstainless steel.
Top Cap – Removable top cap provided with all drill-mount poles.
Finish – Ultraviolet resistant and pigmented approximately the samecolor as the final polyurethane coating. Dark bronze (DDB) isstandard. Must specify color.
Base Cover – Full base cover is optional and finished to match pole.
Intended UseFor 6’ to 30’ mounting height.
INSTALLATION NOTES:
Installation requires grout to be packed under base toensure full contact with foundation. Factory-suppliedtemplates must be used when setting anchor bolts.American Electric Lighting will not accept claim forincorrect anchorage placement due to failure to useAmerican Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping mustbe removed immediately upon delivery to prevent finishdamage.
Ordering Information: See page 191(Note: Poles are available only in U.S.)
SSF 4” Shaft
SSF 5” Shaft
P R O D U C T O V E R V I E W
208 Product Guide For more information please visit our website:www.americanelectriclighting.com
STCDirect Burial PolesSquare Tapered Concrete
FeaturesShaft – Concrete mix has a minimum 28-day compressive strength of8,500 PSI and conforms with ASTM-C150. Prestressing steelreinforcement is uncoated 7 wire, stress relieved strand per ASTM-A416. Steel spiral reinforcement conforms to ASTM-A82 and is notless than .120 (11-gauge) diameter. Poles have a continuous taper of0.165 inches per foot.
Handhole – A 3"x5" handhole is located 18" above ground line and a 21/2" x 7" minimum conduit entrance is located 18" below ground line.Inserts for the handhole and conduit entrance are non-corrosive andweatherproof. Handhole frames and covers conform to ASTM-B240.
Grounding – An 18" long, #4 stranded copper pigtail, connected toreinforced strand, is provided at pole top and at cable entrance belowgrade.
Hardware – Fasteners are high-strength galvanized or stainless steel.
Finish – Smooth, natural form finish, soft gray color is standard.
Intended UseFor direct burial, 16’ to 38’ mounting height.
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Approx.Catalog mount. Shaft Size 80 Max 90 Max 100 Max. ship wt.Number ht. (ft.) (in. x in. x ft.) mph wt. mph wt. mph wt. (lbs.)
STC 13-4X 10 4.0 x 4.0 x 13 3.5 100 3.5 430 3.5 330 189STC 20 7-24X 16 4.0 x 7.24 x 20 22 550 16 430 13 330 680STC 20 9-24X 16 6.0 x 9.24 x 20 48 1,220 37 950 29 760 1,110STC 24 4-80X 20 4.8 x 4.8 x 24 3.5 510 N/A N/A N/A N/A 517STC 24 5-60X 20 5.6 x 5.6 x 24 3.5 510 3.5 390 N/A N/A 686STC 24 6-40X 20 6.4 x 6.4 x 24 3.5 510 3.5 390 3.5 300 917STC 25 8-05X 20 4.0 x 8.05 x 25 21 510 16 390 12 300 985STC 25 10-05X 20 6.0 x 10.05 x 25 44 1,050 34 810 26 640 1,530STC 30 8-86X 25 4.0 x 8.86 x 30 20 460 15 340 11 250 1,350STC 30 10-86X 25 6.0 x 10.86 x 30 49 1,090 33 830 28 650 2,000STC 35 9-67X 29 4.0 x 9.67 x 35 17 400 12 290 8 200 1,800STC 35 11-67X 29 6.0 x 11.67 x 35 43 1,010 32 760 24 580 2,540STC 35 6-40X 30 6.4 x 6.4 x 35 3.5 400 N/A N/A N/A N/A 1,337STC 35 7-25X 30 7.25 x 7.25 x 35 3.5 1,010 3.5 760 N/A N/A 1,685STC 36-8X 30 8.0 x 8.00 x 36 3.2 920 3.5 670 3.5 500 2,145STC 40 12-48X 34 6.0 x 12.48 x 40 42 820 30 590 22 420 3,130STC 45 13-29X 38 6.0 x 13.29 x 45 41 820 31 590 21 420 3,795STC 46-8X 40 8.0 x 8.0 x 46 3.5 820 N/A N/A N/A N/A 2,740STC 47 9-25X 40 9.25 x 9.25 x 47 3.5 820 3.5 000 N/A N/A 3,813
INSTALLATION NOTES:
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must beremoved immediately to prevent finish damage.
Ordering Information: See page 191 (Note: Poles are available only in U.S.)
209Product Guide
P R O D U C T O V E R V I E W
INSTALLATION NOTES:
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must beremoved immediately to prevent finish damage.
SPRTCDirect Burial Poles
Round Tapered Concrete Sportslighting
FeaturesShaft – Concrete mix has a minimum 28-day compressive strength of11,000 PSI and conforms with ASTM-C150. Prestressing steelreinforcement is uncoated 7 wire, stress relieved strand per ASTM-A416. Steel spiral reinforcement conforms to ASTM-A82 and is notless than .203 (5-gauge wire) diameter. Poles have a continuous taperof 0.216 inches per foot. Poles are centrifugally spun and round incross-section with a hollow center.
Handhole – 4"x8" handhole is located 24" above ground line. 4"x8"conduit entrance is located 18" below ground line. 2 1/2"x8" reinforced
handhole with flush cover is located at cage/crossarm locations. 1-1/2" coupling wire inlet/outlet is located opposite this handhole.Inserts for handhole and conduit entrance are non-corrosive andweatherproof. Handhole frames and covers conform to ASTM-B240.
Grounding – A continuous solid or stranded copper ground wire iscast into the pole. Wire terminates at top of pole to accept a 1/2"x24"lightning rod. Copper coupling, approximately 12” below grade,provides a 1/2" tapped insert at pole face for grounding hardware.
Hardware – Fasteners are high-strength galvanized or stainless steel.
Finish – Smooth, natural form finish, soft gray color is standard.
Intended UseFor 45’ to 115’ mounting height.
Technical InformationEPA (ft2) with 1.3 gust
Nom. Pole Approx.Catalog mount. Shaft Size 80 Max 90 Max 100 Max. Ship wt.Number ht. (ft.) (in. x in. x ft.) mph wt. mph wt. mph wt. (lbs.)
SPRTC C6 45 7-17 38 6.75 X 16.47 X 45 31 620 24 480 18 360 3,400SPRTC C5 45 7-17 38 6.75 X 16.47 X 45 39 780 30 600 23 460 3,400SPRTC C4 45 7-17 38 6.75 X 16.47 X 45 52 1,040 40 800 31 589 3,450SPRTC C4 60 7-20 50 6.75 X 19.71 X 60 47 893 35 665 26 520 5,450SPRTC C2 60 9-22 50 8.82 X 21.78 X 60 85 1,615 65 1,235 48 912 7,950SPRTC H1 60 9-22 50 8.82 X 21.78 X 60 138 2,622 101 1,919 80 1,520 8,100SPRTC C3 70 9-24 60 8.82 X 23.94 X 70 56 1,064 42 798 32 608 9,900SPRTC C1 70 9-24 60 8.82 X 23.94 X 70 90 1,710 69 1,311 52 988 10,100SPRTC H2 70 10-24 60 8.82 X 23.94 X 70 139 2,641 103 1,957 81 1,539 10,400SPRTC C2 80 9-26 68 8.82 X 26.1 X 80 63 1,197 45 855 34 646 12,300SPRTC C1 80 9-26 68 8.82 X 26.1 X 80 85 1,445 65 1,105 48 816 12,300SPRTC H2 80 10-26 68 8.82 X 26.1 X 80 136 2,584 101 1,919 79 1,501 12,800SPRTC C2 90 9-28 77 8.82 X 28.26 X 90 54 1,026 39 741 28 532 14,850SPRTC C1 90 9-28 77 8.82 X 28.26 X 90 78 1,482 56 1,064 42 798 14,950SPRTC H2 90 10-28 77 8.82 X 28.26 X 90 132 2,508 97 1,843 75 1,425 15,350SPRTC C1 105 9-32 91 8.82 X 31.5 X 105 70 1,330 49 931 35 665 19,250SPRTC H1 105 9-32 91 8.82 X 31.5 X 105 99 1,881 74 1,406 54 1,026 19,450SPRTC H3 105 11-34 91 11.0 X 33.68 X 105 144 2,736 105 1,995 80 1,520 22,050SPRTC C1 115 9-34 100 8.82 X 33.66 X 115 65 1,235 45 855 31 589 22,350SPRTC H1 115 9-34 100 8.82 X 33.66 X 115 96 1,824 70 1,330 50 950 22,550SPRTC H2 115 10-34 100 8.82 X 33.66 X 115 125 2,375 91 1,729 69 1,311 22,800
Ordering Information: See page 191 (Note: Poles are available only in U.S.)
P R O D U C T O V E R V I E W
210 Product Guide For more information please visit our website:www.americanelectriclighting.com
Angle Iron Crossarms for Concrete PolesProjected area is for the crossarm only. The crossarm projected area is addedto the luminaire projected area to get a total effective projected area (EPA).
SPRTCCrossarm OptionsFor Round Tapered Concrete and Wood Sportslighting Poles
ACRCW33-Fixture Angle Arm
ACRCW22-Fixture Angle Arm
ACRCW44-Fixture Angle Arm
6'- 0"1'- 9"
Notes:1 Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88” diameter.
ACRCW6
ACRCW55-Fixture Angle Arm
6-Fixture Angle Arm
Angle Iron CrossarmsFor Concrete Poles
Catalog Arm EPA WeightNumber (sq. ft.) (lbs.)
ACRCW2 1.80 50.0ACRCW3 3.00 86.0ACRCW4 4.50 121.0ACRCW5 5.70 157.0ACRCW6 7.00 193.0
211Product Guide
P R O D U C T O V E R V I E W
Angle Iron Crossarms for Concrete or Wood PolesProjected area is for the crossarm only. The crossarm projected area is addedto the luminaire projected area to get a total effective projected area (EPA).
SPRTCCrossarm Options
For Round Tapered Concrete and Wood Sportslighting Poles
Notes:1 Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88” diameter.
P R O D U C T O V E R V I E W
212 Product Guide For more information please visit our website:www.americanelectriclighting.com
Pre-wired Tubular Crossarms for Concrete or Wood PolesProjected area is for the crossarm only. The crossarm projected area is added tothe luminaire projected area to get a total effective projected area (EPA).
Pre-wired TubularCrossarms
For Concrete PolesCatalog EPA WeightNumber (sq. ft.) (lbs.)
SPXCW2 1.00 23.5SPXCW3 1.80 40.0SPXCW4 2.50 56.5SPXCW5 3.20 73.0SPXCW6 3.90 89.5SPXCW6
SPXCW5
6-Fixture Crossarm
5-Fixture Crossarm
SPXCW4
SPXCW3
SPXCW24-Fixture Crossarm 2-Fixture Crossarm
3-Fixture Crossarm
6.50”
SPRTCCrossarm OptionsFor Round Tapered Concrete and Wood Sportslighting Poles
Notes:1 Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88” diameter.
213Product Guide
P R O D U C T O V E R V I E W
FeaturesShaft – The cross section shall be round or 16-sided with a 4" bendradius. Each pole is a constant tapered hollow steel section and shallbe up to 55 feet in length with a minimum 1 1/2 times diameter slipjoint as standard. The pole shaft sections shall be high strength lowalloy steel conforming to ASTM A572 Grade 65 or ASTM A595 GradeA. The plate shall be single thickness – no laminations.
Anchor Base – Fabricated from hot-rolled carbon steel plate thatconforms to ASTM A36 or ASTM A572 Grade 42.
Handhole – An oval, reinforced handhole rim having a nominaldimension of 4"x6.5". Steel cover with attachment screws included.Handhole is located 18" above base.
Grounding – Nut holder located immediately inside handhole rim isprovided with 1/2" – 13 UNC ground bolt and nut.
Anchor Bolts – Fabricated from commercial-quality hot-rolled carbonsteel with minimum-yield strength of 55,000 PSI. Bolts have an "L"bend on one end.
Hardware – Fasteners are high-strength galvanized or zinc-plated orstainless steel.
Top Cap – Weather-proof removable top cap provided with all drill-mount poles.
Intended Use
For 40’ to 80’ mounting height.
SPRTSAnchored Base Poles
Round Tapered Steel
Technical InformationEPA (ft2) with 1.3 gust
Nom. Base Wall Base Wall Bolt Bolt Num. ofCatalog mount. Dia. Thick. Dia. Thick. 80 Max. 90 Max. 100 Max. Circle Size AnchorNumber ht (ft.) (in.) (in.) (in.) (in.) mph wt. mph wt. mph wt. (in.) (in. x in. x in.) Bolts
SPRTS 40 HT01 40 — — 9 0.1193 17.2 430 13.5 338 10.8 270 12.5 1 x 36 x 4 4SPRTS 40 HT02 40 — — 9 0.1793 26.1 654 20.6 517 16.7 419 12.5 1.25 x 42 x 6 4SPRTS 40 HT03 40 — — 10 0.1793 38.6 965 30.6 765 24.6 615 13.5 1.25 x 42 x 6 4SPRTS 50 HT01 50 — — 10 0.1193 13.2 330 10.6 265 8.3 208 13.5 1 x 36 x 4 4SPRTS 50 HT02 50 — — 10 0.1793 20.5 512 16.5 412 13.6 340 13.5 1.25 x 42 x 6 4SPRTS 50 HT03 50 — — 11 0.1793 29.9 748 23.5 588 18.6 465 15 1.25 x 42 x 6 4SPRTS 50 HT04 50 — — 13 0.1793 50.4 1,260 39.7 992 31.4 785 17 1.50 x 54 x 6 4SPRTS 50 HT05 50 — — 13 0.2391 69.2 1,730 55.0 1,375 44.2 1,105 17.5 1.75 x 84 x 6 4SPRTS 60 HT01 60 5 0.1196 11.5 0.1793 20.0 600 16.0 480 13.0 390 16 1.25 x 42 x 6 4SPRTS 60 HT02 60 6.5 0.1196 13 0.1793 36.0 1,080 29.0 870 22.0 660 17 1.25 x 42 x 6 6SPRTS 60 HT03 60 6.6 0.1793 13 0.2391 49.0 1,470 40.0 1,200 32.0 960 17 1.50 x 54 x 6 6SPRTS 60 HT04 60 12 0.1793 15.87 0.1875 78.0 2,340 62.0 1,860 50.0 1,500 21 1.50 x 54 x 6 6SPRTS 70 HT01 70 6.6 0.1793 13 0.1793 20.6 515 16.7 417 13.7 342 17 1.50 x 54 x 6 4SPRTS 70 HT02 70 6.6 0.1793 13 0.2391 23.8 595 19.3 482 15.9 397 17.5 1.75 x 84 x 6 4SPRTS 70 HT03 70 12 0.1793 14.57 0.1875 39.0 1,170 30.0 900 23.0 690 19 1.25 x 42 x 6 6SPRTS 70 HT04 70 12 0.1793 15.87 0.1875 52.0 1,560 41.0 1,230 33.0 990 21 1.50 x 54 x 6 6SPRTS 70 HT05 70 12 0.1793 16.82 0.1875 65.0 1,950 53.0 1,590 42.0 1,260 22.75 1.50 x 54 x 6 6SPRTS 80 HT01 80 12 0.1793 15.87 0.1875 37.0 1,110 29.0 870 23.0 690 21 1.50 x 54 x 6 6SPRTS 80 HT02 80 12 0.1793 16.82 0.1875 45.0 1,350 36.0 1,080 28.0 840 22.75 1.50 x 54 x 6 6SPRTS 80 HT03 80 13 0.1875 17.53 0.2092 58.0 1,740 46.0 1,380 35.0 1,050 23 1.50 x 54 x 6 6SPRTS 80 HT04 80 12 0.1793 18.7 0.1875 70.0 2,100 56.0 1,680 44.0 1,320 23 1.50 x 54 x 6 8
Ordering Information: See page 191 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Installation requires grout to be packed under base to ensure full contact with foundation. Factory-suppliedtemplates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to useAmerican Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage.
4-Bolt
Handhole Handhole Handhole
6-Bolt 8-Bolt
P R O D U C T O V E R V I E W
214 Product Guide For more information please visit our website:www.americanelectriclighting.com
Angle Iron Crossarms for Steel PolesProjected area is for the crossarm only. The crossarm projected areais added to the luminaire projected area to get a total effectiveprojected area (EPA).
SPRTSCrossarm OptionsFor Round Tapered Steel Sportslighting Poles
Pre-wired TubularCrossarms
For Steel Poles
Catalog Arm EPA WeightNumber (sq. ft.) (lbs.)
ACR2 1.74 30.0ACR3 2.73 47.0ACR4 3.97 68.0ACR5 5.95 103.0ACR6 7.37 127.0
ACR6
ACR5 ACR4
ACR3 ACR2
6-Fixture Angle Arm
5-Fixture Angle Arm
3-Fixture Angle Arm 2-Fixture Angle Arm
4-Fixture Angle Arm
215Product Guide
P R O D U C T O V E R V I E W
Tubular Crossarms for Steel PolesProjected area is for the crossarm only. The crossarm projected areais added to the luminaire projected area to get a total effectiveprojected area (EPA).
SPRTSCrossarm Options
For Round Tapered Steel Sportslighting Poles
Tubular CrossarmsFor Steel Poles
Catalog EPA WeightNumber (sq. ft.) (lbs.)
CR2 1.28 44.0CR3 2.45 65.0CR4 3.21 98.0CR5 4.17 116.0CR6 5.13 150.0CR7 6.10 176.0CR8 7.06 271.0
CR77-Fixture Crossarm
CR88-Fixture Crossarm
CR55-Fixture Crossarm
CR33-Fixture Crossarm
CR22-Fixture Crossarm
CR44-Fixture Crossarm
CR66-Fixture Crossarm
216 Product Guide For more information please visit our website:www.americanelectriclighting.com
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
Example: R T A U 2 0 6 G B M A U S 8 V D B A A E L
FeaturesPole Construction — Spun-tapered seamless 6063 alloy aluminumtubing, heat-treated to produce a T6 temper. Circumferential satin-brushed finish. The shaft is cone-tapered to the butt diameter.
3 sections cast from A356 alloy aluminum, the anchor base is heat-treated to a T6 condition. The anchor base telescopes the pole shaftand is circumferentially welded at both the top and the bottom.
A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole iscentered 18" above the base.
Removable cast aluminum top cap provided.
All screws, nuts and bolts are made of stainless steel.
A356 nut covers are included with each anchor base unlessotherwise specified.
Pole Finish — Brushed aluminum (BA) is standard. Optional polyesterpowder paint and anodized finishes available.
Pole Grounding System — A ground lug located immediately insidethe handhole is tapped for 3/8"-16 UNC ground bolt (provided byothers).
Pole Installation — Anchor bolts — Top portion of anchor bolt isgalvanized per ASTM A-153. Made of steel rod having a minimumyield strength of 55,000 psi.
Mounting Arm Construction — Body of the mounting arm is taperedaluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at theluminaire end. The pole end of the arm is welded to an aluminum alloy6063-T6 mounting plate.
Welding follows AWS and CSA standards. Arms are chemicallycleaned after fabrication.
Mounting — The mounting plate is designed to be bolted to the shaftusing four 1/2" stainless steel bolts, nuts and washers. A grommet isprovided for the 1-1/4" diameter wiring hole between the pole shaftand the bracket arm.
Mounting Arm Finish — Satin aluminum is standard. Optionalpolyester powder paint and anodized finishes available.
Intended Use20’ to 40’ fixture mounting.
RTAUAnchor Base Poles / Mounting Arm ComboRound Tapered Aluminum Pole with Mounting Arm
Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, please add AEL after the last option
RTAU
RTAU
Shipped InstalledL/AB Less Anchor BoltsFBC Full Base Cover
VD Vibration DamperTP Tamper Proof
HAAxx1,2 Horizontal Arm Bracket (1 fixture)
FDLxx1 Festoon Outlet Less Electrical
12CPxx1 1/2" Coupling34CPxx1 3/4" Coupling
1CPxx1 1" Coupling12NPxx1 1/2" Threaded Nipple34NPxx1 3/4" Threaded Nipple
1NPxx1 1" Threaded NippleHHxx1 Extra Handhole
Architectural Colors (powder finish)3
Standard ColorsBA Brushed
Aluminum (std) DDB Dark Bronze
DWH WhiteDBL Black
Class 1 Arch. Anodize ABL BlackADB Dark BronzeANA Natural
BMA Bolt-on Mast Arm
US4 4' Arm LengthUS6 6' Arm LengthUS8 8' Arm Length
20 - 40 feet(See Chart Opposite)
(See ChartOpposite)
Options
Arm Length4
Nominal ShaftBase Size/
Wall Thickness
MountingFixture MountingHeight
Shaft/arm type
Notes:
1 Specify location and orientation whenordering option.For 1st "x": Specify the height in feet above base of pole.Use two digits to specify height:Example: 5ft = 05 and 20ft = 20For 2nd "x": Specify orientation from handhole (A,B,C,D)Refer to the Handhole Orientation diagram on this page.
2 Horizontal arm is 18" x 2-3/8" O.D. tenon standard.
3 Other colors available, please contact local AEL representative.
4 Some restrictions apply, see back page for details.
Handhole
Arm locatedon side B
217Product Guide
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
Example: R T A U 2 0 6 G B M A 2 U S 4 B A V D A E L
FeaturesPole Construction — Spun-tapered seamless 6063 alloy aluminumtubing, heat-treated to produce a T6 temper. Circumferential satin-brushed finish. The shaft is cone-tapered to the butt diameter.
Cast from A356 alloy aluminum, the anchor base is heat-treated to aT6 condition. The anchor base telescopes the pole shaft and iscircumferentially welded at both the top and the bottom.
A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole iscentered 18" above the base.
Cast aluminum cap provided.
All screws, nuts and bolts are made of stainless steel.
A356 nut covers are included with each anchor base unlessotherwise specified.
Pole Finish — Brushed aluminum (BA) is standard. Optional polyesterpowder paint and anodized finishes available.
Pole Grounding System — A ground lug located immediately insidethe handhole is tapped for 3/8"-16 UNC ground bolt (not supplied).
Pole Installation — Anchor bolts — Top portion of anchor bolt isgalvanized per ASTM A-153. Made of steel rod having a minimumyield strength of 55,000 psi.
Mounting Arm Construction — Body of the mounting arm is taperedaluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at theluminaire end. The pole end of the arm is welded to an aluminum alloy6063-T6 mounting plate.Welding follows AWS and CSA standards.Arms are chemically cleaned after fabrication.
Mounting — The mounting plate is designed to be bolted to the shaftusing four 1/2" stainless steel bolts, nuts and washers. A grommet isprovided for the 1-1/4" diameter wiring hole between the pole shaftand the bracket arm.
Mounting Arm Finish — Satin aluminum is standard. Optionalpolyester powder paint and anodized finishes available.
Intended Use20’ to 40’ fixture mounting.
RTAUAnchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Twin Mounting Arms
RTAU
RTAU
Shipped InstalledL/AB Less Anchor BoltsFBC Full Base Cover
VD Vibration DamperTP Tamper Proof
HAAxx1,2 Horizontal Arm Bracket (1 fixture)
FDLxx1 Festoon Outlet Less Electrical
12CPxx1 1/2" Coupling34CPxx1 3/4" Coupling
1CPxx1 1" Coupling12NPxx1 1/2" Threaded Nipple34NPxx1 3/4" Threaded Nipple
1NPxx1 1" Threaded NippleHHxx1 Extra Handhole
Architectural Colors (Powder Finish)3
Standard ColorsBA Brushed
Aluminum (std) DDB Dark Bronze
DWH WhiteDBL Black
Class 1 Arch. Anodize ABL BlackADB Dark BronzeANA Natural
BMA Bolt-on Mast Arm
2US4 4' Arm Length2US6 6' Arm Length2US8 8' Arm Length
20 - 40 feet(See Chart Opposite)
(See ChartOpposite)
Options
Arm Length4
Nominal ShaftBase Size/
Wall Thickness
MountingFixture MountingHeight
Shaft/Arm Type
Notes:
1 Specify location and orientation whenordering option.For 1st "x": Specify the height in feet above base of pole.Use two digits to specify height:Example: 5ft = 05 and 20ft = 20For 2nd "x": Specify orientation from handhole (A,B,C,D)Refer to the Handhole Orientation diagram on this page.
2 Horizontal arm is 18" x 2-3/8" O.D. tenon standard.
3 Other colors available, please contactyour local American Electric Lighting representative.
4 Some restrictions apply, see chart for details. Handhole
Armslocated onsides B & D
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
218 Product Guide For more information please visit our website:www.americanelectriclighting.com
Technical InformationEPA (ft2) with 1.3 gust
Fixture Mtg. Mtg. Arm Pole Shaft Wall (Max per arm) Max. Weight Bolt App. ShipAEL Catalog Number Height1 length Diam. thickness EPA ft2 with 1.3 gust per arm Circle Bolt Size Weight
(feet) (feet) (in. x in.) (in.) 80 mph 90 mph 100 mph (lbs.) (in.) (inches) (pounds)
RTAU 20 6G BMA 2US4 20' 4' 4" x 6" 0.188 2 2 2 80 9-10 3/4 x 30 x 3 107RTAU 20 6G BMA 2US6 20' 6' 4" x 6" 0.188 2 2 1.9 80 9-10 3/4 x 30 x 3 110RTAU 20 6E BMA 2US8 20' 8' 4" x 6" 0.188 2 2 0.8 80 9-10 3/4 x 30 x 3 112RTAU 20 6E BMA 2US4 20' 4' 4" x 6" 0.156 2 2 1.5 80 9-10 3/4 x 30 x 3 94RTAU 20 6E BMA 2US6 20' 6' 4" x 6" 0.156 2 1.9 0.9 80 9-10 3/4 x 30 x 3 97RTAU 20 6E BMA 2US8 20' 8' 4" x 6" 0.156 2 0.8 n/a 80 9-10 3/4 x 30 x 3 99RTAU 25 6G BMA 2US4 25' 4' 4" x 6" 0.188 2 1.3 0.6 80 9-10 3/4 x 30 x 3 117RTAU 25 6E BMA 2US6 25' 6' 4" x 7" 0.156 2 1.8 0.8 80 9-10 1 x 36 x 4 120RTAU 25 7E BMA 2US6 25' 6' 4" x 7" 0.188 2 2 1.5 80 10-11 1 x 36 x 4 135RTAU 25 7E BMA 2US4 25' 4' 4" x 7" 0.156 2 2 1.3 80 10-11 1 x 36 x 4 144RTAU 25 7E BMA 2US6 25' 6' 4" x 7" 0.156 2 1.8 0.8 80 10-11 1 x 36 x 4 147RTAU 25 7E BMA 2US8 25' 8' 4" x 7" 0.156 2 0.7 n/a 80 10-11 1 x 36 x 4 134RTAU 30 8G BMA 2US4 30' 4' 4.5" x 8" 0.188 2 2 2 80 11-12 1 x 36 x 4 183RTAU 30 8G BMA 2US6 30' 6' 4.5" x 8" 0.188 2 2 1.9 80 11-12 1 x 36 x 4 186RTAU 30 8G BMA 2US8 30' 8' 4.5" x 8" 0.188 2 2 0.9 80 11-12 1 x 36 x 4 188RTAU 30 8E BMA 2US4 30' 4' 4.5" x 8" 0.156 2 2 1.3 80 11-12 1 x 36 x 4 160RTAU 30 8E BMA 2US6 30' 6' 4.5" x 8" 0.156 2 1.8 0.8 80 11-12 1 x 36 x 4 163RTAU 30 8E BMA 2US8 30' 8' 4.5" x 8" 0.156 2 0.8 n/a 80 11-12 1 x 36 x 4 165RTAU 30 7E BMA 2US4 30' 4' 4.5" x 7" 0.156 2 2 1.3 80 10-11 1 x 36 x 4 156RTAU 30 7E BMA 2US6 30' 6' 4.5" x 7" 0.156 2 1.8 0.8 80 10-11 1 x 36 x 4 159RTAU 30 7E BMA 2US8 30' 8' 4.5" x 7" 0.156 2 2 0.9 80 10-11 1 x 36 x 4 161RTAU 35 8G BMA 2US4 35' 4' 4.5" x 8" 0.188 2 1.8 0.8 80 11-12 1 x 36 x 42 14RTAU 35 8G BMA 2US6 35' 6' 4.5" x 8" 0.188 2 1.3 n/a 80 11-12 1 x 36 x 42 17RTAU 35 8J BMA 2US4 35' 4' 4.5" x 8" 0.250 2 2 2 80 11-12 1 x 36 x 4 263RTAU 35 8J BMA 2US6 35' 6' 4.5" x 8" 0.250 2 2 2 80 11-12 1 x 36 x 4 266RTAU 35 8J BMA 2US8 35' 8' 4.5" x 8" 0.250 2 2 1.1 80 11-12 1 x 36 x 4 268RTAU 35 8E BMA 2US6 35' 6' 4.5" x 8" 0.156 2 1.3 n/a 80 11-12 1 x 36 x 4 190RTAU 35 8E BMA 2US8 35' 8' 4.5" x 8" 0.156 2 2 1.1 80 11-12 1 x 36 x 4 192RTAU 40 8G BMA 2US8 40' 8' 4.5" x 8" 0.188 2 2 1.3 80 11-12 1 x 36 x 4 241RTAU 40 8L BMA 2US6 40' 6' 4.5" x 8" 0.219 2 2 2 80 11-12 1 x 36 x 4 271RTAU 40 8J BMA 2US6 40' 6' 4.5" x 8" 0.250 2 1.9 0.8 80 11-12 1 x 36 x 4 301RTAU 40 8J BMA 2US8 40' 8' 4.5" x 8" 0.250 2 0.9 n/a 80 11-12 1 x 36 x 4 303RTAU 40 8J BMA 2US4 40' 4' 4.5" x 8" 0.250 2 2 1.4 80 11-12 1 x 36 x 4 298
RTAUAnchor Base Poles / Mounting Arm ComboRound Tapered Aluminum Pole with Twin Mounting Arms
219Product Guide
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
IMPORTANT: • Do not erect poles without having fixtures installed.• Factory-supplied templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorageplacement due to failure to use factory template.
• If poles are stored outside, all protective wrapping must be removedimmediately to prevent finish damage.
• Installation requires grout be packed under base to ensure full contact withfoundation.
IMPORTANT: • These specifications are intended for general purposes only. American
Electric Lighting reserves the right to change material or design, withoutprior notice, in a continuing effort to upgrade its products.
Shaft Bolt Bolt Base Warehouse TemplateBase Circle Projection Square Anchor Bolt NumberSize A B C Description
6" 9"–10" 3-1/2" 10" AB30-0 PJ500337" 10"–11" 4-1/8" 10-1/2" AB36-0 PJ500348" 11"–12" 4-1/4" 11-1/2" AB36-0 PJ50035
1. Denotes fixture mounting heights, NOT nominal pole height.
18”
B
Peripherallyreinforcedhandhole door
Cast aluminumnut cover
Grout
RTAUAnchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Twin Mounting Arms
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
220 Product Guide For more information please visit our website:www.americanelectriclighting.com
Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
Example: R T S U 2 5 S M P U S 4 G A L V V D A E L
RTSUAnchor Base Poles / Mounting Arm ComboRound Tapered Steel Pole with Single Mounting Arm
FeaturesPole Construction — Weldable-grade hot-rolled, commercial-qualitycarbon steel tubing with a minimum yield of 55,000 psi. Uniform wallthickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are one-piece construction with a full-length longitudinal high-frequencyresistance weld. Round in cross-section having a uniform taper ofapproximately .14" per foot.
Anchor base is fabricated from hot-rolled carbon steel plate thatconforms to ASTM A36.
A reinforced handhole having nominal dimensions of 3" x 5" for shaftsless than 6.25" base diameter and 4" x 6.5" for all other shafts. Coverwith attachment screws included. Handhole is located 18" above thebase.
Weatherproof, removable top cap provided.
Fasteners are high-strength galvanized zinc-plated or stainless steel.
Intended Use20’ to 40’ fixture mounting.
Pole Finish — Galvanized Steel (GALV) is standard. Optional polyesterpowder paint finishes available.
Pole Grounding System — A ground lug is located immediately insidethe handhole rim.
Pole Installation — Anchor bolts — Fabricated from commercial-quality, hot-rolled carbon steel with minimum yield strength of 55,000psi. Bolts have an "L" bend on one end.
Mounting Arm Construction — Body is 2-3/8" O.D. (2" NPS) galvanizedsteel tube (sch. 40 material, min. yield strength 36,000 psi).
Welding follows AWS standards. Arms are galvanized after fabrication.
Mounting Arm Hardware — Mounting plate is designed to be bolted tothe shaft using a 1/2" steel bolt Simplex mount. Single-bolt (US4, US6,US8) or multi-bolt design (US10, US12).
Mounting Arm Finish — Galvanized Steel (GALV) is standard. Optionalpolyester powder paint finishes available.
RTSU
RTSU
Shipped InstalledL/AB Less Anchor BoltsFBC Full Base Cover
VD Vibration DamperTP Tamper Proof
HASxx1,2 Horizontal Arm Bracket (1 fixture)
FDLxx1 Festoon Outlet Less Electrical
12CPxx1 1/2" Coupling34CPxx1 3/4" Coupling1CPxx1 1" Coupling
12NPxx1 1/2" Threaded Nipple34NPxx1 3/4" Threaded Nipple
1NPxx1 1" Threaded NippleHHxx1 Extra Handhole
Architectural Colors (powder finish)3
Standard ColorsGALV Galvanized
Finish (std)DDB Dark Bronze
DWH WhiteDBL Black
SMP US4 Single-bolt Simplex Mount, 4'Arm Length
SMP US6 Single-bolt Simplex Mount, 6'Arm Length
SMP US8 Single-bolt Simplex Mount, 8'Arm Length
MSMP US10 Multi-bolt Simplex Mount , 10' Arm Length
MSMP US12 Multi-bolt Simplex Mount , 12' Arm Length
20 - 40 feet(See ChartOpposite)
(See ChartOpposite)
OptionsNominal Shaftbase size/
wall thickness
Mounting / Arm Length4Fixture mounting
heightShaft/arm type
Notes:
1 Specify location and orientation whenordering option.For 1st "x": Specify the height in feet above base of pole.Use two digits to specify height:Example: 5ft = 05 and 20ft = 20For 2nd "x": Specify orientation from handhole (A,B,C,D)Refer to the Handhole Orientation diagram on this page.
2 Horizontal arm is 18" x 2-3/8" O.D. tenon standard.
3 Other colors available, please contact your local American Electric Lighting representative.
4 Some restrictions may apply, seechart for details.
221Product Guide
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
Technical InformationEPA (ft2) with 1.3 gust
Fixture Mtg. Mtg. Arm Pole Base Wall (Max per arm) Max Weight Bolt AEL Catalog Number Height1 length Diameter thickness EPA ft2 w/ 1.3 gust up to per arm Circle Bolt Size
(feet) (feet) (.14 taper rate) (in.) 100 mph (lbs) (in.) (inches)
RTSU 20 5-9B SMP US4 20' 4' 5.9" 0.120 2 76 9 1 x 36 x 4RTSU 20 5-9B SMP US6 20' 6' 5.9" 0.120 2 76 9 1 x 36 x 4RTSU 20 5-9B SMP US8 20' 8' 5.9" 0.120 2 76 9 1 x 36 x 4RTSU 25 5-9B SMP US4 25' 4' 5.9" 0.120 2 76 9 1 x 36 x 4RTSU 25 5-9B SMP US6 25' 6' 5.9" 0.120 2 76 9 1 x 36 x 4RTSU 25 5-9B SMP US8 25' 8' 5.9" 0.120 2 76 9 1 x 36 x 4RTSU 20 6-5B SMP US4 20' 4' 6.5" 0.120 2 76 9.5 1 x 36 x 4RTSU 20 6-5B SMP US6 20' 6' 6.5" 0.120 2 76 9.5 1 x 36 x 4RTSU 20 6-5B SMP US8 20' 8' 6.5" 0.120 2 76 9.5 1 x 36 x 4RTSU 25 7B SMP US4 25' 4' 6.8" 0.120 2 76 10.5 1 x 36 x 4RTSU 25 7B SMP US6 25' 6' 6.8" 0.120 2 76 10.5 1 x 36 x 4RTSU 25 7B SMP US8 25' 8' 6.8" 0.120 2 76 10.5 1 x 36 x 4RTSU 25 7B MSMP US10 25' 10' 6.8" 0.120 2 76 10.5 1 x 36 x 4RTSU 25 7B MSMP US12 25' 12' 6.8" 0.120 2 76 10.5 1 x 36 x 4RTSU 30 8B SMP US4 30' 4' 8" 0.120 2 76 11 1 x 36 x 4RTSU 30 8B SMP US6 30' 6' 8" 0.120 2 76 11 1 x 36 x 4RTSU 30 8B SMP US8 30' 8' 8" 0.120 2 76 11 1 x 36 x 4RTSU 30 8B MSMP US10 30' 10' 8" 0.120 2 76 11 1 x 36 x 4RTSU 30 8B MSMP US12 30' 12' 8" 0.120 2 76 11 1 x 36 x 4RTSU 35 8-5B SMP US4 35' 4' 8.5" 0.120 2 76 11.5 1 x 36 x 4RTSU 35 8-5B SMP US6 35' 6' 8.5" 0.120 2 76 11.5 1 x 36 x 4RTSU 35 8-5B SMP US8 35' 8' 8.5" 0.120 2 76 11.5 1 x 36 x 4RTSU 35 8-5B MSMP US10 35' 10' 8.5" 0.120 2 76 11.5 1 x 36 x 4RTSU 35 8-5B MSMP US12 35' 12' 8.5" 0.120 2 76 11.5 1 x 36 x 4RTSU 40 9B SMP US4 40' 4' 9" 0.120 2 76 12.5 1 x 36 x 4RTSU 40 9B SMP US6 40' 6' 9" 0.120 2 76 12.5 1 x 36 x 4RTSU 40 9B SMP US8 40' 8' 9" 0.120 2 76 12.5 1 x 36 x 4RTSU 40 9F MSMP US10 40' 10' 9" 0.180 2 76 12.5 1.25 x 42 x 6RTSU 40 9F MSMP US12 40' 12' 9" 0.180 2 76 12.5 1.25 x 42 x 6
Shaft Bolt 1 Bolt Base Warehouse TemplateBase Circle Projection Square Anchor Bolt NumberSize A B C Description
5.9" B 9" 3-1/2"–4-1/4" 10" AB36-0 PJ500756.5" B 9.5" 3-1/2"–4-1/4" 10-1/2" AB36-0 PJ500747.0" B 10" 3-1/2"–4-1/4" 10-7/8" AB36-0 PJ500778.0" B 11" 3-1/2"–4-1/4" 11-1/2" AB36-0 PJ500798.5" B 11.5" 3-3/4"–4-1/2" 12" AB36-0 PJ500829.0" B 12.5" 3-3/4"–4-1/2" 12-3/8" AAB36-0 PJ500859.0" F 12.5" 4-1/2"–5-1/4" 12-3/8" N/A PJ50086
IMPORTANT: • Do not erect poles without having fixtures installed.• Factory-supplied templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorageplacement due to failure to use factory template.
• If poles are stored outside, all protective wrapping must be removedimmediately to prevent finish damage.
• Installation requires grout be packed under base to ensure full contactwith foundation.
1. Denotes fixture mounting heights, NOT nominal pole height.
IMPORTANT: • These specifications are intended for general purposes only. American Electric
Lighting reserves the right to change material or design, without prior notice, in acontinuing effort to upgrade its products.
RTSUAnchor Base Poles / Mounting Arm Combo
Round Tapered Steel Pole with Single Mounting Arm
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
222 Product Guide For more information please visit our website:www.americanelectriclighting.com
Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
Example: A M A W T 2 0 U S 4 S A A E L
AMAW / SMAWAMAW: Aluminum Mounting Arm, Wood PolesSMAW: Steel Mounting Arm, Wood Poles
FeaturesConstruction
Aluminum — Body is schedule 10 (T14) or schedule 40 (T20)aluminum pipe 6005-T5. Base is 3/8" aluminum plate.
Welding follows AWS standard. Arms are pressure-washed afterfabrication.
Intended UseMounting roadway fixtures to wood poles.
Steel — Body is galvanized steel tube (per ASTM A-123) constructedfrom A500 Grade B steel. Base is 3/16" plate.
Welding follows AWS standards. Arms are galvanized afterfabrication.
Finish — Satin aluminum or galvanized steel is standard. Optionalpolyester powder finishes available.
Hardware not included
AMAWSMAW
Standard FinishSA Satin Aluminum
(standard w/ AMAW)GALV Galvanized Steel (standard w/ SMAW)
Architectural Colors (powder finish)1
Standard ColorsDDB Dark Bronze
DWH WhiteDBL Black
US2-5 2-1/2' Arm LengthUS4 4' Arm LengthUS6 6' Arm length2
US8 8' Arm Length2
T14 1 - 2/3” O.D. (1 - 1/4” NPS)T20 2 - 3/8” O.D. (2” NPS)
OptionsArm Length (feet)Pipe SizeSeries
Notes:
1 Other colors available, please contact your local American Electric Lighting representative.
2 Not available with AMAWT14.
223Product Guide
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
AMAW / SMAW
Nominal Dimensions Weight (Max per arm) Max WeightAEL Catalog Number Arm Length (inches) (pounds) EPA ft2 w/ 1.3 gust per arm
(feet) A B C up to 100mph (lbs)
AMAW T14 US2-5 2'6" 30" 15" 10" 3 2 76AMAW T14 US4 4' 42" 19" 10" 4 2 76AMAW T14 US6 6' 66" 24" 12" 6 2 76AMAW T20 US2-5 2'6" 30" 15" 10" 6 2 76AMAW T20 US4 4' 42" 10" 10" 7 2 76AMAW T20 US6 6' 66" 24" 12" 10 2 76AMAW T20 US8 8' 90" 30" 15" 12 2 76
SMAW T14 US2-5 2'6" 30" 15" 10" 9 2 76SMAW T14 US4 4' 42" 19" 10" 11 2 76SMAW T14 US6 6' 66" 24" 12" 15 2 76SMAW T14 US8 8' 90" 30" 15" 20 2 76SMAW T20 US2-5 2'6" 30" 15" 10" 15 2 76SMAW T20 US4 4' 42" 19" 10" 18 2 76SMAW T20 US6 6' 66" 24" 12" 24 2 76SMAW T20 US8 8' 90" 30" 15" 30 2 76
IMPORTANT:
• These specifications are intended for general purposes only. AmericanElectric Lighting reserves the right to change material or design, withoutprior notice, in a continuing effort to upgrade its products.
CAUTION:
• The arms described herein are designed for applications in areas of normalwinds. Consult the factory prior to the design of systems to be mounted onstructures such as bridges or buildings, or areas known to have abnormalwinds such as airports or coastal areas. Failure to consider these factorsin the system design could result in the failure of the pole or mast arm, andconsequently personal injury or property damage.
AMAW / SMAWAMAW: Aluminum Mounting Arm, Wood Poles
SMAW: Steel Mounting Arm, Wood Poles
C
A
B
.562" Dia.
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
224 Product Guide For more information please visit our website:www.americanelectriclighting.com
Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
Example: A M A C T 2 0 U S 4 S A A E L
AMAC / SMACAMAC: Aluminum Mounting Arm, Concrete PolesSMAC: Steel Mounting Arm, Concrete Poles
FeaturesConstruction
Aluminum — Body is schedule 10 (T14) or schedule 40 (T20) aluminumpipe 6005-T5. Base is 3/8" aluminum plate.
Welding follows AWS standard. Arms are pressure-washed afterfabrication.
Intended UseMounting roadway fixtures to concrete poles.
Steel — Body is galvanized steel tube (per ASTM A-123) constructedfrom A500 Grade B steel. Base is 3/16" plate.
Welding follows AWS standards. Arms are galvanized afterfabrication.
Finish — Satin aluminum or galvanized steel is standard. Optionalpolyester powder paint finishes available.
Hardware not included
AMACSMAC
Standard FinishSA Satin Aluminum
(standard w/ AMAW)GALV Galvanized Steel (standard w/ SMAW)
Architectural Colors (powder finish)1
Standard ColorsDDB Dark Bronze
DWH WhiteDBL Black
US4 4' Arm lengthUS6 6' Arm Length2
US8 8' Arm Length2
T14 1 - 2/3” O.D. (1 - 1/4” NPS)T20 2 - 3/8” O.D. (2” NPS)
OptionsArm Length (feet)Pipe SizeSeries
Notes:
1 Other colors available, please contact your local American Electric Lighting representative.
2 Not available with AMAWT14.
225Product Guide
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
AMAW / SMAW
Nominal Dimensions Weight (Max per arm) Max WeightAEL Catalog Number Arm Length (inches) (pounds) EPA ft2 w/ 1.3 gust per arm
(feet) A B C up to 100mph (lbs)
AMAC T14 US4 4' 42" 18" 10" 6 2 76AMAC T20 US4 4' 42" 18" 10" 8 276AMAC T20 US6 6' 66" 24" 12" 11 2 76AMAC T20 US8 8' 90" 30" 15" 14 276
SMAC T14 US4 4' 42" 18" 10" 13 2 76SMAC T14 US6 6' 66" 24" 12" 17 276SMAC T14 US8 8' 90" 30" 15" 21 2 76SMAC T20 US4 4' 42" 18" 10" 18 2 76SMAC T20 US6 6' 66" 24" 12" 24 276SMAC T20 US8 8' 90" 30" 15" 30 2 76
IMPORTANT:
• These specifications are intended for general purposes only. AmericanElectric Lighting reserves the right to change material or design, withoutprior notice, in a continuing effort to upgrade its products.
CAUTION:
• The arms described herein are designed for applications in areas of normalwinds. Consult the factory prior to the design of systems to be mounted onstructures such as bridges or buildings, or areas known to have abnormalwinds such as airports or coastal areas. Failure to consider these factorsin the system design could result in the failure of the pole or mast arm, andconsequently personal injury or property damage.
AMAC / SMACAMAC: Aluminum Mounting Arm, Concrete Poles
SMAC: Steel Mounting Arm, Concrete Poles
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
226 Product Guide For more information please visit our website:www.americanelectriclighting.com
Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
Example: S M A W L T 2 0 U S 4 G A L V A E L
SMAWLMounting ArmSteel Mounting Arm, Wall Mount
FeaturesConstruction — Body is galvanized steel tube (per ASTM A-123)constructed from A500 Grade B steel.
Welding follows AWS standards. Arms are galvanized afterfabrication.
Intended UseWall-mounting roadway fixtures
Finish galvanized steel is standard. Optional polyester powder paintfinishes available.
Hardware not included
SMAWL
SMAWL
Standard FinishGALV Galvanized Steel (standard w/ SMAW)
Architectural Colors (powder finish)1
Standard ColorsDDB Dark Bronze
DWH WhiteDBL Black
US2-5 2 1/2'Arm LengthUS4 4' Arm LengthUS6 6' Arm Length2
US8 8' Arm Length2
T14 1 - 2/3” O.D. (1 - 1/4” NPS)T20 2 - 3/8” O.D. (2” NPS)
OptionsArm Length (feet)Pipe SizeSeries
Notes:
1 Other colors available, please contact your local American Electric Lighting representative.
2 Not available with AMAWT14.
227Product Guide
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
AMAW / SMAW
Nominal Dimensions Weight (Max per arm) Max WeightAEL Catalog Number Arm Length (inches) (pounds) EPA ft2 w/ 1.3 gust per arm
(feet) A B C up to 100mph (lbs)
SMAWL T14 US2-5 2'6" 30" 15" 10" 11 2 76SMAWL T14 US4 4' 42" 19" 10" 13 2 76SMAWL T14 US6 6' 66" 24" 12" 18 2 76SMAWL T20 US2-5 2'6" 30" 15" 10" 17 2 76SMAWL T20 US4 4' 42" 19" 10" 22 2 76SMAWL T20 US6 6' 66" 24" 12" 30 276SMAWL T20 US8 8' 90" 30" 15" 38 2 76
AC
B
.562 Diameter(4 PLCS.)
1/4" Plate
1/4" x 2" Flat Bar
14" 12"
1"
2"
4"
1"
IMPORTANT:
• These specifications are intended for general purposes only. AmericanElectric Lighting reserves the right to change material or design, withoutprior notice, in a continuing effort to upgrade its products.
CAUTION:
• The arms described herein are designed for applications in areas of normalwinds. Consult the factory prior to the design of systems to be mounted onstructures such as bridges or buildings, or areas known to have abnormalwinds such as airports or coastal areas. Failure to consider these factorsin the system design could result in the failure of the pole or mast arm, andconsequently personal injury or property damage.
SMAWLMounting Arm
Steel Mounting Arm, Wall Mount
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
228 Product Guide For more information please visit our website:www.americanelectriclighting.com
Traditional Wood Pole ArmsMast Arms & Brackets - Upsweep Arms(For Horizontally Mounted Luminaires)
Wood Pole MountingCatalog Approx.Number Item Wt. (Lbs.)
91-2401 2' ARM -11/4 '' Aluminum, (Use with Nema Head only) 1-3/4
Dimensions: A-24'', B-123/4'', C-73/8''92-2401 2' ARM -11/4'' Steel, Class E 5-1/2
Dimensions: A-24'', B-123/4'', C- 73/8''91-3001 21/2' ARM -11/4'' Aluminum, (Use with NEMA head only) 2
Dimensions: A-27'', B-123/4'', C-73/8''92-3001 21/2' ARM -11/4'' Steel, Class E 6
Dimensions: A-27'', B-123/4'', C-73/8''91-4801 4' ARM -11/4'' Aluminum, Class B 3-3/4
Dimensions: A-43'', B-213/4'', C-87/8''92-4801 4' ARM -11/4'' Steel, Class E 10
Dimensions: A-43'', B-211/2'', C-85/8''91-4802 4' ARM -2'' Aluminum, Class D 6-1/2
Dimensions: A-43'', B-211/4'', C-85/8''92-4802 4' ARM -2'' Steel, Class E 17-1/2
Dimensions: A-43'', B-211/2'', C-87/8''92-7201 6' ARM -11/4'' Steel, Class C 17-1/2
Dimensions: A-661/4'', B-291/2'', C-83/8''91-7202 6' ARM -2'' Aluminum, Class B 9
Dimensions: A-661/4'', B-291/2'', C-83/8''92-7202 6' ARM -2'' Steel, Class D 25-1/2
Dimensions: A-661/4'', B-291/2'', C-83/4''94-9602 8' ARM -2'' Steel, Class D 40
Dimensions: A-901/4'', B-297/8'', C-81/2''93-7201 6' ARM -11/4'' Aluminum, Class B 6-3/4
Dimensions: A-661/4'', B-291/2'', C-83/4''94-7201 6' ARM -11/4'' Steel, Class E 18
Dimensions: A-661/4'', B-291/2'', C-83/4''93-7202 6' ARM -2'' Aluminum, Class D 11
Dimensions: A-661/4'', B-29'', C-77/8''94-9601 8' ARM -11/4'' Steel, Class C 26-1/2
Dimensions: A-901/4'', B-291/2'', C-83/4''93-9602 8' ARM -2'' Aluminum, Class B 13-1/2
Dimensions: A-901/4'', B-291/2'', C-77/8''
229Product Guide
Notes:1. CLASS CHART — Denotes the maximum size luminaire recommended for use.
Both weight and projected area must be considered. Classifications based onAmerican Electric Lighting standards. See Isotach Wind Map, page 189.
Luminaire Class A B C D EWeight (in pounds) 30 40 60 80 100Effective Projected Area 1.5 2.0 3.0 4.0 5.0
2. Steel mast arms constructed in accordance with ASTM specification A-36.3. For more information, please contact your local American Electric Lightingrepresentative.
CAUTION: The poles and mast arms described herein are designed for groundmounted applications in areas of normal winds. Consult the factory prior to thedesign of systems to be mounted on structures such as bridges or buildings, orareas known to have abnormal winds such as airports or coastal areas. Failureto consider these factors in the system design could result in the failure of thepole or mast arm, and consequently personal injury or property damage.
Concrete Pole Mounting
P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M A T I O N
Catalog Approx.Number Item Wt. (Lbs.)
90-2001 20” ARM -1¼'' Steel, Class E 10Dimensions: A-20'', B-15'', C-12''
90-4801 4' ARM -1¼'' Steel, Class E 16Dimensions: A-48'', B-25'', C-12''
90-7202 6' ARM -2'' Steel, Class D 29Dimensions: A-72'', B-34'', C-12''
90-9602 8' ARM -2'' Steel, Class D 48Dimensions: A-96'', B-34'', C-12''
Traditional Concrete Pole ArmsMast Arms & Brackets - Upsweep Arms
(For Horizontally Mounted Luminaires)
230 Product Guide For more information please visit our website:www.americanelectriclighting.com
NOTES
231
TECHNICAL DATA, TERMS AND CONDITIONS
HPS Replacement Starters...................................232
Lamp Selection .......................................................233
Fuse Ratings ....................................................234-239
Luminaire Classification Systems........................240
Floodlighting Applications. ...................................241
Floodlighting Calculations.....................................242
Roadway Lighting Calculations............................243
Terms & Conditions ........................................244-245
Index .................................................................246-247
For technical support, please call:
1-800-754-0463or email:
www.americanelectriclighting.com
H P S R E P L A C E M E N T S T A R T E R S
232 Product Guide
Technical Data
Catalog Number Description
IGN 3L 36 OB 50/150 3 Lead 3/16” Terminal Open Board 55V
IGN 3L 36 OB 200/400 3 Lead 3/16” Terminal Open Board 100V
IGN 3L 14 OP 50/150 3 Lead 1/4” Terminal Open Plug 55V
IGN 3L 14 OP 200/400 3 Lead 1/4” Terminal Open Plug 100V
IGN 3L 14 EC 50/150 3 Lead 1/4” Terminal Encapsulated 55V
IGN 3L 14 EC 200/400 3 Lead 1/4” Terminal Encapsulated 100V
IGN 2L 36 OB 50/150 2 Lead 3/16” Terminal Open Board 55V
IGN 2L 36 OB 200/400 2 Lead 3/16” Terminal Open Board 100V
IGN 2L 14 OP 50/150 2 Lead 1/4” Terminal Open Plug 55V
IGN 2L 14 OP 200/400 2 Lead 1/4” Terminal Open Plug 100V
IGN 2L 14 EC 50/150 2 Lead 1/4” Terminal Encapsulated 55V
IGN 2L 14 EC 200/400 2 Lead 1/4” Terminal Encapsulated 100VIGN 2L 36 OB DUAL 50/400 2 Lead 3/16” Terminal Open Board Dual 55/100V1
IGN 2L 14 OP DUAL 50/400 2 Lead 1/4” Terminal Open Plug Dual 55/100V1
IGN 2L 14 EC DUAL 50/400 2 Lead 1/4” Terminal Encapsulated Dual 55/100V1
IGN 2L 14 EC DUAL UNI 2 Lead 1/4” Terminal Encapsulated Dual Universal
IGN 2L 14 OP DUAL UNI 2 Lead 1/4” Terminal Open Plug Dual Universal
Notes:
1 Ships as 55V, converts to 100V by removing jump wire.
For photometric information please visit our website:www.americanelectriclighting.com
233Product Guide
L A M P S E L E C T I O N
Technical Data
Quartz Low Pressure Metal High PressureIncandescent Sodium Halide Sodium
Efficiency Poor Best Good Better20 LPW 183 LPW 90 LPW 105 LPW
Mean Life Low Medium High High2K Hrs 18K Hrs 12K Hrs 24K Hrs
Lumen High High Medium HighMaintenance 97% 100%(+9) 80% 90%
Color Best Very Poor Good FairMonochrome
System C.U. Good Fair Good Good
Hot Restart Instant 1 Minute 15 Minutes 1 Minute
Warm-Up Instant 10 Minutes 10 Minutes* 5 Minutes
System Cost Lowest High High High
*Pulse Start MH
Typical Lamp Typeswith Watts and Initial Lamp Lumens
Lamp Initial MeanType Watts Lumens Lumens Avg. Life
35 2250 2025 2400050 4000 3600 2400070 6300 5500 24000
High 100 9500 8000 24000Pressure 150 16000 13800 24000Sodium 200 22000 19800 24000
250 29000 26100 24000310 37000 32300 24000400 50000 45000 240001000 130000 120700 24000
175 12800 9300 7500250 20000 14100 7500
Metal 400 32000 20500 15000Halide 400 (BT28) 32000 20500 15000
(Horizontal) 1000 107800 86000 120001500 153000 127400 3000
175 16000 112000 150000Pulse 250 23800 16600 15000Start 320 32000 21000 15000Metal 350 37000 28000 20000Halide 400 41000 32800 20000
(Horizontal) 1000 120000 96000 20000
Recommended Minimum MountingHeights for Various Lamps
High Pressure Metal Halide Minimum MountingSodium Lamp Lamp Height (Ft)
50W 8.070W 12.0
100W 15.0150W 175W 18.0200W 20.0250W 25.0310W 400W 30.0400W 35.0
1000W 1000W 40.0
Maintenance FactorsIf maintained footcandle level is desired, multiply the areacoverage per fixture by the maintenance factor.
Maintenance factor is determined by multiplying the lamplumen depreciation factor (LLD) by the luminaire dirtdepreciation factor (LDD). The lamp lumen depreciationfactor is usually the mean lumen value of the lamp. Theluminaire dirt depreciation factor range is described inthe Illuminating Engineering Society Handbook. A .9 dirtfactor is commonly used.
Lamp Comparison
234 Product Guide
Technical Data
F U S E R A T I N G S / E N E R G Y C O N S U M P T I O N
07S RN 120 86 2.10 1 8 $37.67 07S RH 120 86 1.30 1 3 $37.67 07S XN 208 91 1.53 2 5 $39.86 07S XN 240 91 1.35 2 3 $39.86 07S XN 277 91 1.17 1 3 $39.86 07S XH 208 91 0.85 2 3 $39.86 07S XH 240 91 0.75 2 2 $39.86 07S XH 277 91 0.65 1 2 $39.86 07S CA 120 95 0.90 1 3 $41.61 07S CA 208 95 0.53 2 2 $41.61 07S CA 240 95 0.48 2 2 $41.61 07S CA 277 95 0.43 1 2 $41.61 07S CA 480 95 0.23 2 2 $41.61 07S CT 120 95 0.86 1 3 $41.61 07S CT 208 95 0.50 2 2 $41.61 07S CT 240 95 0.43 2 2 $41.61 07S MR 120 103 0.90 1 3 $45.11 07S MR 240 103 0.45 2 2 $45.11 07S MR 480 103 0.23 2 2 $45.11 10S RN 120 115 3.05 1 10 $50.37 10S RH 120 115 1.80 1 5 $50.37 10S XN 208 130 2.25 2 10 $56.94 10S XN 240 130 1.98 2 5 $56.94 10S XN 277 130 1.53 1 5 $56.94 10S XH 208 130 1.25 2 3 $56.94 10S XH 240 130 1.10 2 3 $56.94 10S XH 277 130 0.85 1 3 $56.94 10S CA 120 138 1.18 1 3 $60.44 10S CA 208 138 0.70 2 3 $60.44 10S CA 240 138 0.60 2 2 $60.44 10S CA 277 138 0.50 1 2 $60.44 10S CA 347 138 0.40 1 2 $60.44 10S CA 480 138 0.29 2 2 $60.44 10S CT 120 130 1.22 1 3 $56.94 10S CT 208 130 0.70 2 2 $56.94 10S CT 240 130 0.61 2 2 $56.9410S CT 277 130 0.52 1 2 $56.94 10S MR 120 138 1.20 1 3 $60.44 10S MR 240 138 0.60 2 2 $60.44 10S MR 480 138 0.30 2 2 $60.44 15S RN 120 170 4.50 1 15 $74.46
Nominal Annual Lamp Ballast Supply Input Fuse Energy
Wattage Circuit Voltage Watts Current Rating Consumption(watts) (volts) (watts) (amps) # of Fuses (Amps) ($)1
Notes
1 Based on $.10/KWH; 12 months operation
For photometric information please visit our website:www.americanelectriclighting.com
235Product Guide
Technical Data
F U S E R A T I N G S / E N E R G Y C O N S U M P T I O N
15S RH 120 170 2.35 1 8 $74.46 15S XN 208 188 2.88 2 10 $82.34 15S XN 240 188 2.52 2 10 $82.34 15S XN 277 188 2.25 1 8 $82.34 15S XH 208 188 1.60 2 5 $82.34 15S XH 240 188 1.40 2 5 $82.34 15S XH 277 188 1.25 1 5 $82.34 15S CA 120 190 1.65 1 5 $83.22 15S CA 208 190 0.95 2 3 $83.22 15S CA 240 190 0.82 2 3 $83.22 15S CA 277 190 0.72 1 3 $83.22 15S CA 480 188 0.42 2 2 $82.34 15S CT 120 190 1.76 1 5 $83.22 15S CT 208 190 1.01 2 3 $83.22 15S CT 240 190 0.88 2 3 $83.22 15S CT 277 190 0.76 1 3 $83.22 15S MR 120 196 1.70 1 5 $85.85 15S MR 240 196 0.90 2 3 $85.85 15S MR 480 196 0.40 2 2 $85.85 17M CA 120 213 1.80 1 5 $93.29 17M CA 208 213 1.10 2 3 $93.29 17M CA 240 213 0.90 2 3 $93.29 17M CA 277 213 0.78 1 2 $93.29 17M CA 347 213 0.62 1 2 $93.29 17M CA 480 213 0.51 2 2 $93.29 17M SC 120 208 1.80 1 5 $91.10 17M SC 208 208 1.05 2 3 $91.10 17M SC 240 208 0.90 2 3 $91.10 17M SC 277 208 0.80 1 3 $91.10 17M SC 347 208 0.65 1 3 $91.10 17M SC 480 206 0.45 2 2 $90.23 20S XN 120 240 6.27 1 20 $105.12 20S XH 120 240 3.48 1 10 $105.12 20S RN 240 218 2.80 2 10 $95.48 20S RH 240 218 1.56 2 5 $95.48 20S CA 120 240 2.22 1 10 $105.12 20S CA 208 240 1.28 2 5 $105.12 20S CA 240 240 1.11 2 5 $105.12 20S CA 277 240 0.96 1 3 $105.12 20S CA 347 240 0.77 1 3 $105.12 20S CA 480 240 0.56 2 2 $105.12
Nominal Annual Lamp Ballast Supply Input Fuse Energy
Wattage Circuit Voltage Watts Current Rating Consumption(watts) (volts) (watts) (amps) # of Fuses (Amps) ($)1
Notes:
1 Based on $.10/KWH; 12 months operation
236 Product Guide
Technical Data
F U S E R A T I N G S / E N E R G Y C O N S U M P T I O N
20S CT 120 235 2.10 1 10 $102.93 20S CT 208 235 1.21 2 3 $102.93 20S CT 240 235 1.05 2 3 $102.93 20S CT 277 235 0.91 1 3 $102.9320S CT 480 235 0.52 2 2 $102.93 20S MR 120 255 2.20 1 10 $111.69 20S MR 240 255 1.10 2 3 $111.69 20S MR 480 255 0.55 2 2 $111.69 20M SC 120 232 2.00 1 5 $101.62 20M SC 208 232 1.20 2 3 $101.62 20M SC 240 232 1.00 2 3 $101.62 20M SC 277 232 0.85 1 3 $101.62 20M SC 347 232 0.70 1 2 $101.62 20M SC 480 232 0.50 2 2 $101.62 25S XN 120 287 8.73 1 22 $125.71 25S XH 120 287 4.85 1 15 $125.71 25S RN 240 282 4.00 2 10 $123.52 25S RH 240 282 2.22 2 10 $123.52 25S CA 120 295 2.50 1 10 $129.21 25S CA 208 295 1.50 2 5 $129.21 25S CA 240 295 1.30 2 5 $129.21 25S CA 277 295 1.10 1 5 $129.21 25S CA 347 295 0.93 1 3 $129.21 25S CA 480 310 0.63 2 2 $135.78 25S CT 120 300 2.75 1 10 $131.40 25S CT 208 300 1.60 2 5 $131.40 25S CT 240 300 1.38 2 5 $131.40 25S CT 277 300 1.19 1 5 $131.40 25S CT 347 300 0.92 1 3 $131.40 25S CT 480 300 0.69 2 2 $131.40 25S MR 120 310 2.80 1 10 $135.78 25S MR 240 310 1.40 2 5 $135.7825S MR 480 310 0.70 2 2 $135.78 25M CA 120 298 2.50 1 10 $130.52 25M CA 208 298 1.45 2 5 $130.52 25M CA 240 298 1.25 2 5 $130.52 25M CA 277 298 1.10 1 5 $130.52 25M CA 347 295 0.90 1 3 $129.21 25M CA 480 295 0.63 2 2 $129.21 25M CT 120 295 2.66 1 10 $129.2125M CT 240 295 1.54 2 5 $129.21
Nominal Annual Lamp Ballast Supply Input Fuse Energy
Wattage Circuit Voltage Watts Current Rating Consumption(watts) (volts) (watts) (amps) # of Fuses (Amps) ($)1
Notes:
1 Based on $.10/KWH; 12 months operation
For photometric information please visit our website:www.americanelectriclighting.com
Product Guide 237
Technical Data
F U S E R A T I N G S / E N E R G Y C O N S U M P T I O N
25M CT 480 295 1.33 2 5 $129.21 25M SC 120 291 2.50 1 10 $127.46 25M SC 208 291 1.45 2 5 $127.46 25M SC 240 291 1.25 2 5 $127.46 25M SC 277 291 1.10 1 5 $127.46 31S CA 120 365 3.37 1 10 $159.8731S CA 208 365 1.94 2 5 $159.87 31S CA 240 365 1.68 2 5 $159.87 31S CA 277 365 1.45 1 5 $159.87 31S CA 480 365 0.84 2 3 $159.87 31S MR 120 380 3.30 1 10 $166.44 31S MR 240 380 1.65 2 5 $166.44 31S MR 480 380 0.83 2 3 $166.44 32M SC 120 368 3.25 1 10 $161.18 32M SC 208 368 1.90 2 5 $161.18 32M SC 240 368 1.65 2 5 $161.18 32M SC 277 368 1.40 1 5 $161.18 32M SC 347 368 1.10 1 5 $161.18 32M SC 480 368 0.80 2 2 $161.18 40S RN 208 440 5.20 2 15 $192.7240S RH 208 440 2.89 2 10 $192.72 40S RN 240 440 6.00 2 15 $192.72 40S RH 240 440 3.33 2 10 $192.72 40S XN 120 463 6.70 1 20 $202.79 40S XH 120 463 3.72 1 10 $202.79 40S CA 120 464 3.80 1 10 $203.23 40S CA 208 464 2.20 2 10 $203.23 40S CA 240 464 1.90 2 5 $203.23 40S CA 277 464 1.70 1 5 $203.23 40S CA 347 464 1.32 1 5 $203.23 40S CA 480 464 0.97 2 3 $203.23 40S CT 120 465 4.20 1 15 $203.67 40S CT 208 465 2.40 2 10 $203.67 40S CT 240 465 2.10 2 10 $203.67 40S CT 277 465 1.82 1 5 $203.67 40S CT 347 465 1.45 1 5 $203.67 40S CT 480 465 1.05 2 5 $203.67 40S MR 120 490 4.20 1 15 $214.62 40S MR 240 490 2.10 2 10 $214.6240S MR 480 490 1.05 2 5 $214.62 40M CA 120 458 4.00 1 10 $200.60
Nominal Annual Lamp Ballast Supply Input Fuse Energy
Wattage Circuit Voltage Watts Current Rating Consumption(watts) (volts) (watts) (amps) # of Fuses (Amps) ($)1
Notes:
1 Based on $.10/KWH; 12 months operation
238 Product Guide238
Technical Data
F U S E R A T I N G S / E N E R G Y C O N S U M P T I O N
40M CA 208 458 2.30 2 10 $200.60 40M CA 240 458 2.00 2 5 $200.60 40M CA 277 458 1.75 1 5 $200.60 40M CA 347 460 1.40 1 5 $201.48 40M CA 480 462 1.00 2 3 $202.36 40M CT 120 465 4.00 1 10 $203.67 40M CT 208 465 2.31 2 10 $203.67 40M CT 240 465 2.00 2 5 $203.67 40M CT 277 465 0.87 1 3 $203.6740M CT 347 462 1.35 1 5 $202.36 40M CT 480 465 1.00 2 3 $203.67 40M SC 120 452 3.80 1 10 $197.98 40M SC 208 452 2.20 2 10 $197.98 40M SC 240 452 1.90 2 5 $197.98 40M SC 277 452 1.65 1 5 $197.98 75S CA 120 840 6.75 1 20 $367.92 75S CA 208 840 4.00 2 10 $367.92 75S CA 240 840 3.50 2 10 $367.92 75M CA 820 120 6.90 1 20 $52.56 75M CA 820 208 3.85 2 10 $91.10 75M CA 820 240 3.45 2 10 $105.12 75M CA 820 277 3.00 1 10 $121.33 75M SC 120 812 7.00 1 20 $355.66 75M SC 208 812 4.00 2 10 $355.66 75M SC 240 812 3.50 2 10 $355.66 X1S CA 120 1100 9.50 1 30 $481.80 X1S CA 208 1100 5.50 2 15 $481.80 X1S CA 240 1100 4.75 2 15 $481.80 X1S CA 277 1100 4.15 1 15 $481.80 X1S CA 347 1100 3.30 1 10 $481.80 X1S CA 480 1100 2.30 2 10 $481.80 X1M CA 120 1070 9.00 1 30 $156.222
X1M CA 208 1070 5.20 2 15 $156.222
X1M CA 240 1070 4.50 2 15 $156.222
X1M CA 277 1070 3.90 1 10 $156.222
X1M CA 347 1070 3.20 1 10 $156.222
X1M CA 480 1080 2.25 2 10 $157.682
X1M SC 120 1080 9.00 1 30 $157.682
X1M SC 208 1080 5.20 2 15 $157.682
X1M SC 240 1080 4.50 2 15 $157.682
X1M SC 277 1080 3.90 1 10 $157.682
Nominal Annual Lamp Ballast Supply Input Fuse Energy
Wattage Circuit Voltage Watts Current Rating Consumption(watts) (volts) (watts) (amps) # of Fuses (Amps) ($)1
Notes:
1 Based on $.10/KWH; 12 months operation2 Based on $.10/KWH; 4 months operation
For photometric information please visit our website:www.americanelectriclighting.com
239Product Guide 239
Technical Data
F U S E R A T I N G S / E N E R G Y C O N S U M P T I O N
X1M SC 347 1080 3.20 1 10 $157.682
X1M SC 480 1070 2.25 2 10 $156.222
X5M CA 120 1605 13.50 1 N/A $234.332
X5M CA 208 1605 7.80 2 20 $234.332
X5M CA 240 1605 6.75 2 20 $234.332
X5M CA 277 1605 5.58 1 15 $234.332
X5M CA 347 1615 4.80 1 15 $235.792
X5M CA 480 1625 3.40 2 10 $237.252
Nominal Annual Lamp Ballast Supply Input Fuse Energy
Wattage Circuit Voltage Watts Current Rating Consumption(watts) (volts) (watts) (amps) # of Fuses (Amps) ($)1
Notes:
1 Based on $.10/KWH; 12 months operation2 Based on $.10/KWH; 4 months operation
240 Product Guide240
L U M I N A I R E C L A S S I F I C A T I O N S Y S T E M S
Technical Data
WIDTH Mounted atCLASSIFICATION Pavement Normally Used for:
Type I Center Roadways up to 2 times themounting height in width
Type II Edge Up to 1 times the mounting heightfor one side mountingUp to 2 times the mounting heightfor both side mounting
Type III Edge Up to 1.5 times the mountingheight for one side mountingUp to 3 times the mounting heightfor both side mounting
Type IV Edge Up to 2 times the mounting heightfor one side mountingUp to 4 times the mounting heightfor both side mounting
Type V Center Up to 4 times the mounting heightin total width
SPACINGCLASSIFICATION Definition Normally Used for:
S Short Spacings up to 4 timesthe mounting height
M Medium Spacings up to 5 times mountingheight
L Long Spacings up to 5 times mountingheight
GLARE CONTROLCLASSIFICATION Definition Normally Used for:
FCO Full-Cutoff Strict control of light above 80 VerticalZero emission above 90 Vertical
CO Cutoff Strict control of lightabove 80 Vertical2.5% emission above 90 Vertical
SCO Semi-Cutoff Medium control of lightabove 80 Vertical
NCO Non-Cutoff No control requirementsabove 80 Vertical
TYPE I
TYPE I - 4 Way
TYPE II
TYPE II - 4 Way
TYPE III
TYPE IV
TYPE V
For photometric information please visit our website:www.americanelectriclighting.com
241Product Guide 241
F L O O D L I G H T I N G A P P L I C A T I O N S
The IES beam spreads indicate the angularranges (horizontally and vertically) throughwhich the intensity of the floodlight is greaterthan 10% of its maximum intensity. This angu-lar range is referred to as the 'Field Angle'.
For example:Asymmetrical beam spread
138° (H) x 119° (V) HORIZONTAL VERTICAL
= IES 7 X 6
IES Beamspread Classification
FieldAngle IES BeamDegrees Type Description
10° up to 18° 1 Very Narrow18° up to 29° 2 Narrow29° up to 46° 3 Medium Narrow46° up to 70° 4 Medium70° up to 100° 5 Medium Wide100° up to 130° 6 Wide130° and up 7 Very Wide
The IES classification was formerly referredto as NEMA Type. The following outdoor design tips providegeneral guidelines for lighting design. Theseguidelines may not apply to all applications.
GROUND-MOUNTED FLOODLIGHTS
Ground-mounted floodlights are used to lightbuilding facades, signs and flagpoles.
Facade LightingWhen lighting building facades with ground-mounted floodlights, three factors are con-sidered: setback, spacing and aiming.
Facade Lighting Considerations:
1. Setback2. Spacing3. Aiming
Setback
The recommended setback is three-fourththe building height. If a building is 30 feet tall,the recommended setback is 22.5 feet fromthe building. Locating the floodlight closer tothe building will sacrifice uniformity; settingit farther back will result in a loss of effi-ciency.
Setback distance = 3/4 x building height3/4 (30 ft.) = 22.5 ft.
Spacing
The rule of thumb for spacing floodlights is notto exceed two times the setback distance. Ifthe setback is 22.5 feet, the floodlights shouldnot be placed more than 45 feet apart.
Spacing = 2 x setback distance22.5 ft. x 2 = 45 ft. apart
Aiming
The floodlight should be aimed at least two-thirds the height of the building. For example,if a building is 30 feet high, the recommendedaiming point is approximately 20 feet high.After installation is complete, aiming can beadjusted to produce the best appearance.Mounting a full or upper visor to the floodlightcan reduce unwanted spill light.
Aiming point = 2/3 x building height2/3 (30 ft.) = 20 ft. high
IES Classifications Sign LightingWhen lighting a sign with ground-mountedfloodlights, there are three considerations:setback, spacing and aiming.
Sign Lighting Considerations:
1. Setback2. Spacing3. Aiming
Setback
When using ground-mounted floodlights tolight a sign, the recommended setback is a dis-tance equal to three-fourth the sign height. Forexample, the setback distance for a 12-foot by6-foot sign would be 4.5 feet. Locating thefloodlight closer will sacrifice uniformity whilesetting it farther back will result in a loss of ef-ficiency.
Setback distance = 3/4 x sign height3/4 (6 ft.) = 4.5 ft.
Spacing
The rule of thumb for spacing floodlights is notto exceed two times the setback distance. Ifthe setback is 4.5 feet, the floodlights shouldnot be placed more than 9 feet apart.
Spacing = 2 x setback distance4.5 ft. x 2 = 9 ft. apart
Technical Data
242 Product Guide242
F L O O D L I G H T I N G C A L C U L A T I O N S
Aiming
The floodlight should be aimed at least two-thirds up the sign. For example, if a sign is sixfeet tall, then the floodlight will be aimed ap-proximately four feet high. After installationis completed, aiming can be adjusted to pro-duce the best appearance. Mounting a full orupper visor to the floodlight can reduce un-wanted glare.
Aiming point = 2/3 x sign height2/3 (6 ft.) = 4 ft. high
Flag LightingGround-mounted floodlights also can be usedto light flags. Setback, spacing and aimingmust all be considered.
Flag Lighting Considerations:1. Setback2. Spacing3. Aiming
Setback
The recommended setback for lighting a flagis one-third times the pole height. If the poleis 30 feet tall, the floodlight should be setback a distance of 10 feet away from the pole.
Setback distance = 1/3 x pole height1/3 (30 ft.) = 10 ft.
'
'
Spacing
Ideally, three floodlights are recommended tolight a flag. The floodlights should be placedapproximately 120° apart.
3 floodlights spaced 120° apart
Aiming
The recommended aiming point for eachfloodlight is the center of the flag or the top ofthe pole. Mounting a full or upper visor to thefloodlight can reduce unwanted spill light.
POLE-MOUNTED FLOODLIGHTSGeneral Area LightingPole-mounted floodlights are commonly usedfor general area lighting applications such asparking lots and storage yards. Mountingheight, spacing, vertical aiming and horizon-tal aiming should be considered.
General Lighting Considerations:1. Mtg. Height2. Spacing3. Vertical aiming4. Horizontal aiming
Mounting Height
The recommended mounting height is one halfthe distance across the area to be lighted. Ifthe area to be lighted is 40 feet across, thelowest recommended mounting height is 20feet.
Mounting height = 1/2 distance to be lighted1/2 (40ft.) = 20 ft.
Spacing
When more than one pole is added, poleplacement is a concern. The "4 times" rule ofthumb for spacing indicates that a pole shouldbe placed four times the mounting height fromthe adjacent poles. If a flood is mounted on a20-foot pole, space the poles 80 feet apart.
Pole spacing = 4 x mounting height4 (20-ft. pole) = 80 feet between poles
Vertical Aiming
A single floodlight uses the two-thirds rule ofthumb for vertical aiming. The fixture is aimed2/3 of the distance across the area to belighted and at least 30° below horizontal. If thearea to be lighted is 40 feet across, therecommended aiming point is 27 feet.
Aiming point = 2/3 across distance to be lighted2/3 (40 ft.) = 27 ft. aiming point
Additionally, to minimize glare, therecommended aiming point distance shouldnever exceed twice the mounting height. If apole is 20 feet high, the vertical aiming pointshould not exceed 40 feet out.
2 (20 ft. mtg. ht.) = 40 ft.
Horizontal Aiming
When an additional floodlight is added to a sin-gle pole, horizontal aiming also must be con-sidered. First, each floodlight should bevertically aimed according to the two-thirdsrule. As long as the floodlight has a horizontalNEMA 6 or 7 beamspread, the floodlights canbe aimed up to 90° apart.
Technical Data
243Product Guide
R O A D W A Y L I G H T I N G C A L C U L A T I O N S
Technical Data
American Electric Lighting offers an extensive line of luminaires for your roadway lighting applications. The calculations which follow will helpyou to determine the type, quantity and placement of these luminaires. You will need data from the Photometric Test Report for the luminaire(s)being considered. Contact your American Electric Lighting representative for these reports. A sample report is provided for your use in thefollowing calculations.
CalculationsInitial Lamp Coefficient of Light Loss
Lumens x Utilization x Factor
Pole Spacing x Road Width
AverageMaintained =Footcandles
Initial Lamp Coefficient of Light LossLumens x Utilization x Factor
Average Maintained RoadFootcandles x Width
PoleSpacing =
Averaged Maintained Pole RoadFootcandles x Spacing x Width
Coefficient x Light LossUtilization Factor
InitialLamp =Lumens
SAMPLE CALCULATIONS
A roadway is to be lighted to a level of 1fc (Average Maintained Footcandles). The roadway is 45 feet wide and the poles are 30 feet high, therefore, the mountingheight ratio is 1.5
The Photometric Test Report provides: Initial Lamp Lumens = 14,000. Coefficient of Utilization (at 1.5MHR) = 43% for the 175W MH lamp used in an American ElectricLighting LUXMASTER LUMINAIRE.
The Light Loss Factor provided in the preceding charts for the 175W MH lamp is 0.70. Initial Lamp Lumens are also provided in this chart.
Pole Spacing =14,000 (ILL) x .43 (CU) x .70 (LLF)
= 94 Feet (PS)1 (AMF) x 45 (RW)
If Pole Spacing is known, then Average Maintained Footcandles can be calculated:
Average Maintained Footcandles =14,000 (ILL) x .43 (CU) x .70 (LLF)
= .996 (AMF)94 (PS) x 45 (RW)
Or Initial Lamp Lumens can be calculated:
Initial Lamp Lumens =1 (AMF) x 94 (PS) x 45 (RW)
= 14,000 (ILL).43 (CU) x .70 (LLF)
Other application data may be determined by similar calculations. Contact your local American Electric Lighting representative for assistance.
AMF - Average Maintained FootcandlesCU - Coefficient of UtilizationILL - Initial Lamp LumensMHR - Mounting Height RatioLLF - Light Loss FactorPS - Pole SpacingRW - Road Width
244 Product Guide
TERMS AND CONDITIONS OF SALEFor Shipments Within the United States*
Effective August 25, 2008
TERMS:The words we, our and us shall refer to American Electric Lighting (“AEL”) , a division ofAcuity Brands Lighting, Inc. and the words purchaser, you and your, shall refer to theperson or entity purchasing products under this Agreement. PAYMENT TERMS:A 1% cash discount will be allowed on invoices paid in full by the 10th of the monthfollowing the month of billing. All payments made after the 10th are due on a net basis tothe 25th (1% 10th prox, net 25th prox).
FREIGHT ALLOWANCE:Shipments are F.O.B. our plants, distribution centers or field warehouses as follows:
• All factory orders having a distributor price of$3,000 or more for one consignee for one releasequalify for freight allowed.
• Warehouse orders of stock items having adistributor price of $3,000 or more for oneconsignee for one release qualify for freight allowed.
• All orders having a distributor price of less than$3,000 will be assessed freight and handling charges.
• Anchor bolts are included with American ElectricLighting poles. Pre-shipped anchor bolts having adistributor price of less than $3,000 will be assessedfreight and handling charges.
We reserve the right to route all orders that qualify for freight allowance at ourdiscretion. AEL will ship in the manner selected by the purchaser provided that thepurchaser assumes all additional transportation costs.DELIVERY:AEL shall not be liable for any delay or default in delivering products for any reasonbeyond the reasonable control of AEL, including, but not limited to, armed conflict oreconomic dislocation resulting therefrom; embargoes; shortages of labor, raw materials,fuels, energy, production facilities or transportation; labor difficulties, civil disorders ofany kind; action of civil or military authorities (including priorities and allocations); fires,floods, and accidents. No liability shall be incurred by AEL by reason of its not filling anyorder or portion thereof due to any of these or similar circumstances.
TRANSPORTATION CLAIMS:AEL’s equipment is tested for mechanical defects prior to shipping. AEL’s packaging isregularly inspected by transportation authorities who assume responsibility for bothapparent and concealed damages sustained by improper handling. Title passes topurchaser upon delivery by AEL to the carrier, and all claims for damages or shortages intransit shall be made by the purchaser to the delivering carrier. AEL will be glad to assistwhen called upon, provided notification is given in writing within 15 business days ofreceipt of shipment.
PACKAGING:AEL reserves the right to alter the quantities of any order so as to conform to standardpackaging.
PRICES:Prices are subject to change without notice. In the event of price increases, all orderson hand will be filled at the lower prices provided that such orders are released forshipping prior to the effective date of the price increase. If the orders are not released forshipment prior to the effective date of the price increase, the orders will be billed at theprices in effect at the time of shipment. Special quoted orders which cannot be releasedfor shipping prior to the price increase effective date may be subject to an increase inprice. Minimum billing is $100 net excluding orders for replacement parts only. Ordersfor parts totaling less than $15 will be billed $15 lump sum. Prices do not include lampsunless so specified.
RETURN MERCHANDISE:No merchandise may be returned without prior written authorization from AEL factories.Requests to return merchandise must be made with AEL’s agents for transmittal to thefactory within four (4) months from date of shipment by AEL. All returns must be shippedprepaid to the location designated on the return authorization. Credit will be issued basedon the original invoice price, or price in effect at time of return, whichever is lower, less arestocking charge of 25% (minimum) of the purchase price (to partially defray our cost ofhandling), less reconditioning and replacing costs if necessary, and less the freightexpense of the original shipment. The reconditioning charge will be determined by theamount of repairs, refinishing or reconditioning required to restore the merchandise tosaleable condition. All non-stocking, special, custom-made, outdated, or modifiedversions of normal factory stocking items are not returnable. Authorization will not begranted when the value of all items to be returned is less than $100. Returns from anyone order will be limited to not more than 10% of the total order value.
SERVICE AREA LIMITATION: AEL reserves the right to refuse to make quotations, accept orders or make shipments topoints of destination outside of the regular or assigned selling and service area of thedistributor.
GUARANTEE:AEL warrants all equipment to be free from defect in manufacturing, under normal andproper storage, installation, and use, for a period of one (1) year. In addition we provide asix (6) year warranty on the factory installed electrical system (which consists of theballast, ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and wiring) insideAEL products. AEL’s guarantee liability extends only to the repair or replacement of thedefective part, at AEL’s option, and no labor charges for correction of the defect by repairor replacement will be honored by AEL unless prior written authority has been granted byAEL’s Customer Service Department.THE FOREGOING GUARANTEE TERMS ARE EXCLUSIVE AND IN LIEU OF ALL OTHERGUARANTEES. AEL MAKES NO REPRESENTATIONS OR WARRANTIES EXCEPT ASEXPRESSLY SET FORTH IN THESE TERMS AND CONDITIONS, AND AEL EXPRESSLYDISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED,INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY ORFITNESS FOR A PARTICULAR PURPOSE. NO DISTRIBUTOR OR SUPPLIER OF AEL HASTHE AUTHORITY TO MODIFY OR AMEND THIS GUARANTEE.
LIMITATION OF LIABILITY:The foregoing guarantee provides the purchaser’s sole and exclusive remedy relating toAEL’s products. The total liability of AEL on any and all claims of any kind, whether incontract, warranty, tort (including negligence), strict liability or otherwise, arising out of orin connection with, or resulting from, AEL’s performance or breach of the foregoing limitedwarranty or from AEL’s sale, delivery, repair, or replacement of any products, or thefurnishing of any services, shall in no event exceed the purchase price allocable to thespecific product which gives rise to the claim, and any and all such liability shallterminate upon the expiration of the limited warranty set forth above. IN NO EVENTSHALL AEL BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, ORPUNITIVE DAMAGES, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES,WHETHER AS THE RESULT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDINGNEGLIGENCE), STRICT LIABILITY, OR ANY OTHER THEORY.
CANCELLATION CHARGES:Orders for stocking items may be cancelled prior to shipping without charge. All otherorders may not be cancelled unless AEL is reimbursed for all work already performed andfor all special materials purchased by AEL. If an order is cancelled after shipment or ifdelivery is refused at the delivery destination, all warehousing, delivery and return costswill be charged to the purchaser.
GENERAL:Possession of a price sheet does not entitle you to purchase any merchandise.Specifications are subject to change without notice. Consult factory for verification. Thecompliance of AEL’s product to individual project specifications and the approval for theiruse is not warranted by AEL.
ACCEPTANCE:Acceptance of orders can be made only at AEL’s plants, distribution centers or fieldwarehouses for warehouse orders on the basis of these terms and conditions of sale.Acceptance of orders is limited to the terms and conditions hereof. AEL hereby objects toany additional or different terms offered by the purchaser in its sales order or any otherdocument of purchaser. Such additional or different terms shall not become a part of anyorder without the express written consent of AEL.
ENTIRE AGREEMENT:Except as expressly agreed in writing signed by AEL, the terms and conditions statedabove shall constitute the entire sales agreement between AEL and the purchaser. Anycontrary or additional terms or conditions submitted by the purchaser (other than thedescription of the products being ordered and the requested quantities, shipping date,and shipping location contained in purchaser’s purchase order) shall be deemed to be ofno force or effect and are hereby rejected. Purchaser’s submission of a purchase ordershall indicate purchaser’s acknowledgment of and agreement with these Terms andConditions.
American Electric Lighting reserves the right to change these Terms and Conditions ofSale without notice.
* For shipments outside the United States, contact factory for applicable Terms and Conditions of Sale.
245Product Guide
TERMS AND CONDITIONS OF SALEFor Shipments Within Canada*
Effective August 25, 2008
TERMS:
The words we, our and us shall refer to American Electric Lighting Canada (“AEL”), adivision of Acuity Brands Lighting, Inc. and the words purchaser, you and your, shall referto the person or entity purchasing products under this Agreement.
PAYMENT TERMS:
Payment terms are 2% -10 or Net 30 days. 2%-10 days means that all invoices dated fromthe first to the 15th of the month are payable on the 25th of the same month. All invoicesfrom the 15th to the 30th of the month are payable on the 10th of the following month.Alternatively, all invoices are due Net 30 days following invoice date.
FREIGHT ALLOWANCE:
Shipments are F.O.B. our plants, Lachine, Quebec, and St. Hyacinthe, Quebec, and ourCanadian field warehouses.
• Warehouse or factory orders must equal $3,000 U.S. or more for shipment to one consignee for one release to qualify for freight allowance.
• All orders having a distributor price of less than $3,000 U.S. will be assessedfreight and handling charges.
• Special shipping requirements by the purchaser that cause additionalshipping expenses above the normal shipping expenses will be charged to the purchaser.
DELIVERY:
AEL shall not be liable for any delay or default in delivering products for any reasonbeyond the reasonable control of AEL, including, but not limited to, armed conflict oreconomic dislocation resulting therefrom; embargoes; shortages of labor, raw materials,fuels, energy, production facilities or transportation; labor difficulties, civil disorders ofany kind; action of civil or military authorities (including priorities and allocations); fires,floods, and accidents. No liability shall be incurred by AEL by reason of its not filling anyorder or portion thereof due to any of these or similar circumstances.
TRANSPORTATION CLAIMS:
Our equipment is tested for mechanical defects prior to shipping. Our packaging isregularly inspected by transportation authorities who assume responsibility for bothapparent and concealed damages sustained by improper handling. Title passes topurchaser upon delivery by AEL to the carrier, and all claims for damages or shortages intransit shall be made by the purchaser to the delivering carrier. AEL will be glad to assistwhen called upon, provided notification is given in writing within 15 business days ofreceipt of shipment.
PACKAGING:
AEL reserves the right to alter quantities of any order so as to conform to standardpackaging.
PRICES:
Prices are subject to change without notice. In the event of price increases, all orders onhand will be filled at the lower prices provided that such orders are released forshipping prior to the effective date of the price increase. If the orders are not released forshipment prior to the effective date of the price increase, the orders will be billed at theprices in effect at the time of the shipment. Special quoted orders which cannot bereleased for shipping prior to the price increase effective date may be subject to anincrease in price. Minimum billing is $100 net excluding orders for replacement partsonly. Orders for parts totaling less than $50 will automatically be billed $50 lump sum.Prices do not include lamps unless so specified. Prices exclude all taxes.
RETURN MERCHANDISE:
No merchandise may be returned without prior written authorization from AEL factories.Requests to return merchandise must be made with our agents for transmittal to thefactory within four (4) months from date of shipment by us. All returns must be shippedprepaid to the location designated on the return authorization. Credit will be issued basedon the original invoice price, or price in effect at time of return, whichever is lower, less arestocking charge of 25% (minimum) of the purchase price (to partially defray our cost ofhandling), less reconditioning and replacing costs if necessary, and less the freightexpense of the original shipment. The reconditioning charge will be determined by theamount of repairs, refinishing or reconditioning required to restore the merchandise to asaleable condition. All non-stocking, special, custom-made, outdated, or modifiedversions of normal factory stocking items are not returnable. Authorization will not begranted when the value of all items to be returned is less than $100. Returns from anyone order will be limited to not more than 10% of the total order value.
DROP SHIPMENTS:
AEL reserves the right to refuse to make direct shipments to points of destination outsideof the regular or assigned selling and service area of the distributor.
GUARANTEE:
AEL warrants all equipment to be free from defect in manufacturing, under normal andproper storage, installation, and use, for a period of one (1) year. In addition, AEL providesa six (6) year warranty on the factory installed electrical system (which consists of theballast, ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and wiring) insideAEL products. AEL’s guarantee liability extends only to the repair or replacement of thedefective part, at AEL’s option, and no labor charges for correction of the defect by repairor replacement will be honored by AEL unless prior written authority has been granted byAEL’s Customer Service Department.THE FOREGOING GUARANTEE TERMS ARE EXCLUSIVE AND IN LIEU OF ALL OTHERGUARANTEES. AEL MAKES NO REPRESENTATIONS OR WARRANTIES EXCEPT ASEXPRESSLY SET FORTH IN THESE TERMS AND CONDITIONS, AND AEL EXPRESSLYDISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED,INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY ORFITNESS FOR A PARTICULAR PURPOSE. NO DISTRIBUTOR OR SUPPLIER OF AEL HASTHE AUTHORITY TO MODIFY OR AMEND THIS GUARANTEE.
LIMITATION OF LIABILITY:
The foregoing guarantee provides the purchaser’s sole and exclusive remedy relating toAEL’s products. The total liability of AEL on any and all claims of any kind, whether incontract, warranty, tort (including negligence), strict liability or otherwise, arising out of orin connection with, or resulting from, AEL’s performance or breach of the foregoing limitedwarranty or from AEL’s sale, delivery, repair, or replacement of any products, or thefurnishing of any services, shall in no event exceed the purchase price allocable to thespecific product which gives rise to the claim, and any and all such liability shall terminateupon the expiration of the limited warranty set forth above. IN NO EVENT SHALL AEL BELIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR PUNITIVEDAMAGES, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES, WHETHER ASTHE RESULT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE),STRICT LIABILITY, OR ANY OTHER THEORY.
CANCELLATION CHARGES:
Orders for stocking items may be cancelled prior to shipping without charge. All otherorders may not be cancelled unless AEL is reimbursed for all work already performed andfor all special materials purchased by AEL. If an order is cancelled after shipment or ifdelivery is refused at the delivery destination, all warehousing, delivery, and return costswill be charged to the purchaser.
GENERAL:
Possession of a price sheet does not entitle you to purchase any merchandise. Specifica-tions are subject to change without notice. Consult factory for verification. The complianceof AEL’s product to individual project specifications and the approval for their use is notwarranted by AEL.
ACCEPTANCE:
Acceptance of orders can be made only at AEL’s plants, distribution centers or fieldwarehouses for warehouse orders on the basis of these terms and conditions of sale.Acceptance of orders is limited to the terms and conditions hereof. AEL hereby objects toany additional or different terms offered by the purchaser in its sales order or any otherdocument of purchaser. Such additional or different terms shall not become a part of anyorder without the express written consent of AEL.
ENTIRE AGREEMENT:Except as expressly agreed in writing signed by AEL, the terms and conditions statedabove shall constitute the entire sales agreement between AEL and the purchaser. Anycontrary or additional terms or conditions submitted by the purchaser (other than thedescription of the products being ordered and the requested quantities, shipping date,and shipping location contained in purchaser’s purchase order) shall be deemed to be ofno force or effect and are hereby rejected. Purchaser’s submission of a purchase ordershall indicate purchaser’s acknowledgment of and agreement with these Terms andConditions.
American Electric Lighting Canada reserves the right to change these Terms andConditions of Sale without notice.
*For shipments outside Canada, contact factory for applicable Terms andConditions of Sale.
246 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
Index
ACP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154AMAC / SMAC / Arms for Concrete Poles . . . . . . . . . .224AMAW / SMAW / Arms for Wood Poles . . . . . . . . . . . .222ANSI Color Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186ASA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122AVL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134AVL-BIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132Accessories
Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144Floodlighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168Photocontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186Roadway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
Aluminum Mounting Brackets . . . . . . . . . . . . . . . . . . . .203American Revolution Deluxe Series . . . . . . . . . . . . . . . .62American Revolution Series 247 . . . . . . . . . . . . . . . . . . . .64AmeriSport™ Series ASP . . . . . . . . . . . . . . . . . . . . . . . .164
Bainbridge Series 870 . . . . . . . . . . . . . . . . . . . . . . . . . . . .68Ballast Matrices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148Decorative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100Floodlighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173Roadway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Branson . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
Contempo Series 245 . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 Corvus™ CVM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .10Corvus™ CVL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Cresthill Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74Cresthill Sphere . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76Cresthill Centennial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78Cresthill Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
D7790 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181DBE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184DD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182DE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178DP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
DP1704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176DPN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183DUX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180DX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179Decorative Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Chadsworth Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90New Albany Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92Statesboro Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94Waycross Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96Weatherproof Receptacles . . . . . . . . . . . . . . . . . . . . . .98
DuraStar® Series 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14DuraStar® Series 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Dusk To Dawn Series DTD . . . . . . . . . . . . . . . . . . . . . . . .114
Energy Saver Series CES . . . . . . . . . . . . . . . . . . . . . . . .160
Georgian Series GRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Heavy-Duty Wallpack 882 . . . . . . . . . . . . . . . . . . . . . . . . .46
InterState™ II 775 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
LPS Roadway - SRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40LPS Roadway - SP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42Lexington . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82LuxMaster® Luminaire Series 53 . . . . . . . . . . . . . . . . . .136LuxMaster® Luminaire Series 153 . . . . . . . . . . . . . . . . .138LuxMaster® Classic Series LM . . . . . . . . . . . . . . . . . . . .142LuxMaster® Classic Series LS . . . . . . . . . . . . . . . . . . . .140
Marietta Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Multi-Mount™ 285 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
NEMA Head 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108NEMA Head Package Series 11 PKG . . . . . . . . . . . . . .110
PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126PES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124Photocontrol Recommendation Chart . . . . . . . . . . . . . .186Pole Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202
247Product Guide
Index
Pole Technical DataFlorida Wind Rating . . . . . . . . . . . . . . . . . . . . . . . . . . .190General Information . . . . . . . . . . . . . . . . . . . . . . . . . . .191Illustrated Samples . . . . . . . . . . . . . . . . . . . . . . . . . . .188Wind Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . . . . . . . . .162Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . . . . . . . . .163
RSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192RTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193RSAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194RSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197RTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198RTAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216RTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205 RTFDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206RTSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220Roadway 115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Roadway 115 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20Roadway 125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Roadway 125 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28Roadway 315 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22Roadway 315 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24Roadway 325 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Roadway 325 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Roadway 327 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
SMAWL / Arms for Wall Mount . . . . . . . . . . . . . . . . . . .226SPRTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209SPRTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213SSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195SSAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196SSF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207SSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199STC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208STS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200STSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201Series 11 “L” Package . . . . . . . . . . . . . . . . . . . . . . . . . . .112Series 165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
Shorting and Open Caps . . . . . . . . . . . . . . . . . . . . . . . . .185SignLite 875 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48Steel Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . .204Sportslighting Series SPF . . . . . . . . . . . . . . . . . . . . . . . .166Sumter Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Technical DataFloodlighting Applications. . . . . . . . . . . . . . . . . . . . . .241Floodlighting Calculations . . . . . . . . . . . . . . . . . . . . .242 Fuse Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234-239HPS Replacement Starters . . . . . . . . . . . . . . . . . . . . .232Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233Luminaire Classification Systems . . . . . . . . . . . . . . .240Roadway Lighting Calculations . . . . . . . . . . . . . . . . .243
Terms & Conditions . . . . . . . . . . . . . . . . . . . . . . . . . .244-245Traditional Concrete Pole Arms . . . . . . . . . . . . . . . . . . .229Traditional Wood Pole Arms . . . . . . . . . . . . . . . . . . . . . .228TwistPack Series TWT . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
UltraFlood™ Series 75 . . . . . . . . . . . . . . . . . . . . . . . . . .156UltraFlood™ Series 77 . . . . . . . . . . . . . . . . . . . . . . . . . . .158Underpass 581/681 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
VLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130VMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128Valiant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
NOTES
248 Product Guide For photometric information please visit our website:www.americanelectriclighting.com
CVMPage 10
CVLPage 12
ValiantTM
Page 60
ASAPage 122
AVL BIAPage 132
ACPPage 154
CESPage 160
PESPage 124
PEMPage 126
NEW in Edition ThreeEdition Three of the American Electric Lighting Product Guide introduces several new products, shown below.Look for the “NEW” icon throughout the catalog to locate these new items.
ARDPage 62
VMRPage 128
DP 1704Page 176
VLRPage 130
Sales Contact______________________________ AEL Customer #____________________________
Contact Email______________________________ Contact Phone _____________________________
To see available product literature, specification sheets, photometric reports and more, please visit us at:
www.americanelectriclighting.com
For Technical Support, contact us at:1-800-754-0463 or [email protected]
N E W
©2008 Acuity Brands Lighting, Inc. AEL-1315.17 4/08 Printed in USA
American Electric LightingAcuity Brands Lighting, Inc.
3825 Columbus Rd. S.W., Granville, OH 43023Phone: 800-754-0463, Fax: 740-349-4490www.americanelectriclighting.com