David Ferguson, Manager Construction Services Purchasing & Materials Management Michael Pacholok, Acting Director City Hall 18th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2 July 23, 2012 Reply to: Michael Porcarelli Via Website Posting: 99 Pages Tel: (416) 338-5585 ADDENDUM NO. 1 TENDER NO. 187-2012 RE: ROOF MEMBRANE REPLACEMENT & DRAIN LINE CLEAN OUT AT TORONTO HESCHEL SCHOOL LOCATED AT 819 SHEPPARD AVE. WEST, TORONTO. REVISED CLOSING DATE: JULY 26, 2012 AT 12 O’CLOCK NOON LOCAL TIME. Please refer to the above Tender Call document in your possession and be advised of the following Revised Closing Date, Revised Price Schedule Form and Clarification of Information: 1. Closing date has been changed from July 25, 2012 at 12 O'Clock noon local time to the revised closing date of July 26, 2012 at 12 O'Clock noon local time. REVISED CLOSING DATE 2. The Price Schedule Form on pages 28 and 29 of 239 is replaced with the enclosed two (2) pages, Revised - Price Schedule Form. REVISED PRICE SCHEDULE FORM a) Total Pricing – Option 1 and Option 2; Added $50,000.00 Cash Allowance line item for possible abatement removal at existing roofing membrane (material presumed to contain asbestos) for roof section areas A, B, C, D, E, F, G, H, J, N and M, as specified for replacement in both Options "1" and "2". 3. The following information is CLARIFICATION OF INFORMATION now provided for clarification purposes: Phase 1 Environmental Assessment Report (dated October 14, 2009): a) Copies of this report were handed out to all in attendance @ the mandatory site meeting on Wednesday, July 18, 2012. This report makes reference to an asbestos survey report as prepared by Golder Associates in 2008. For your information, please find attached A.B.M. (Asbestos Building Materials) report survey as prepared by Golder Associates Ltd. (dated March 2008), for the T.D.S.B. (Toronto District School Board). Should you have any questions regarding this addendum contact Michael Porcarelli, Corporate Buyer, at email [email protected]. Please attach this addendum to your Request for Tender document and be governed accordingly. Bidders must acknowledge receipt of all addenda on the space provided on the Tender Call Cover 1 of 99

Upload: others

Post on 08-Feb-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

David Ferguson, Manager Construction Services

Purchasing & Materials Management Michael Pacholok, Acting Director

City Hall 18th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2

July 23, 2012 Reply to: Michael Porcarelli Via Website Posting: 99 Pages Tel: (416) 338-5585

ADDENDUM NO. 1

TENDER NO. 187-2012

RE: ROOF MEMBRANE REPLACEMENT & DRAIN LINE CLEAN OUT AT TORONTO HESCHEL

SCHOOL LOCATED AT 819 SHEPPARD AVE. WEST, TORONTO.

REVISED CLOSING DATE: JULY 26, 2012 AT 12 O’CLOCK NOON LOCAL TIME. Please refer to the above Tender Call document in your possession and be advised of the following Revised Closing Date, Revised Price Schedule Form and Clarification of Information:

1. Closing date has been changed from July 25, 2012 at 12 O'Clock noon local time to the revised closing date of July 26, 2012 at 12 O'Clock noon local time.

REVISED CLOSING DATE

2.

The Price Schedule Form on pages 28 and 29 of 239 is replaced with the enclosed two (2) pages, Revised - Price Schedule Form.

REVISED PRICE SCHEDULE FORM

a) Total Pricing – Option 1 and Option 2;

Added $50,000.00 Cash Allowance line item for possible abatement removal at existing roofing membrane (material presumed to contain asbestos) for roof section areas A, B, C, D, E, F, G, H, J, N and M, as specified for replacement in both Options "1" and "2".

3.

The following information is CLARIFICATION OF INFORMATION

now

provided for clarification purposes:

Phase 1 Environmental Assessment Report (dated October 14, 2009): a) Copies of this report were handed out to all in attendance @ the mandatory site meeting on Wednesday, July 18, 2012. This report makes reference to an asbestos survey report as prepared by Golder Associates in 2008. For your information, please find attached A.B.M. (Asbestos Building Materials) report survey as prepared by Golder Associates Ltd. (dated March 2008), for the T.D.S.B. (Toronto District School Board).

Should you have any questions regarding this addendum contact Michael Porcarelli, Corporate Buyer, at email [email protected]. Please attach this addendum to your Request for Tender document and be governed accordingly. Bidders must acknowledge receipt of all addenda on the space provided on the Tender Call Cover

1 of 99

David Ferguson, Manager Construction Services

Purchasing & Materials Management Michael Pacholok, Acting Director

City Hall 18th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2

Page as per the Process Terms and Conditions, Section 1, Item 8 - Addenda, of the Tender Call document. All other aspects of the Tender remain the same. Yours truly, David Ferguson, Manager, Construction Services Purchasing & Materials Management

2 of 99

Section 3 – Tender Submission Package Pricing Form

Tender Call No. 187-2012 Contract No. N/A

PMMD V 4.0 Page 3-7

REVISED - PRICE SCHEDULE FORM (July 23, 2012) Roof Membrane Replacement & Drain Line Clean Out at Toronto Heschel School located at 819 Sheppard Ave. West, Toronto. All Bidders Must

Complete In Full And Submit This Price Form Page With Your Bid Submission By The Closing Time And Date.

Bidders That Do Not Fully Complete This Form (Such As Leaving Lines Blank), Or Have Unclear Answers (Such As "N/A" Or "Tbd", Dashes Or Hyphens) Will Be Disqualified. Prices That Are Intended To Be Zero Cost/No Charge To The City Are To Be Submitted In The Space Provided In The Price Schedule As "$0.00" Or "Zero". " All Spaces For The Aforementioned Information Must Be Completed In Ink Ensuring The Printing Is Clear And Legible. Where Included, The Supplementary List Of Prices Required For Extra Work Form Must Also Be Completed. NAME OF CONTRACTOR: __________________________________________________________ The City reserves the right to award work identified for this Tender Price Schedule Form in whole or part should it be deemed in the interest of the City to do so. The City may exercise the option of awarding either Option "1" or Option "2" to the successful proponent, as per the approved budget schedule for this project and scheduled construction start time-line.

ALL PRICES SHALL INCLUDE ALL LABOUR AND MATERIAL.

Table – 1: Pricing – Option 1

(H.S.T. excluded)

Item Description Price ($)

1 Replacement of roof sections A, B, C, E, F, G, H, and M - New Roofing System R1 $_____________________

2 Replacement of roof section J – New Roofing System R2 $_____________________

3 Replacement of roof sections D & N – New Roofing System R5 $_____________________

4 Cleaning and roof repairs on roof sections K and L $_____________________

5 Total (item #1 to item #4) $_____________________

continued …

3 of 99

Section 3 – Tender Submission Package Pricing Form

Tender Call No. 187-2012 Contract No. N/A

PMMD V 4.0 Page 3-8

REVISED - PRICE SCHEDULE FORM (July 23, 2012) Table – 2: Pricing – Option 2

(H.S.T. excluded)

Item Description

Price ($)

1 Replacement of roof sections A, B, C, E, F, G, H, and M - New Roofing System R3 $_____________________

2 Replacement of roof section J – New Roofing System R4 $_____________________

3 Replacement of roof sections D & N – New Roofing System R5 $_____________________

4 Cleaning and roof repairs on roof sections K and L $_____________________

5 Total (item #1 to item #4) $_____________________

Total Pricing – Option 1 and Option 2

1

Total (item #5 from Table – 1: Pricing – Option 1) (H.S.T. excluded)

$_____________________

2

Total (item #5 from Table – 2: Pricing – Option 2) (H.S.T. excluded)

$_____________________

3 Contingency Allowance $ 25,000.00

4 Cash Allowance $ 50,000.00

5 Total of above items 1, 2, 3 and 4 $_____________________

6 HST Calculation (13% of item 5)

$_____________________

Grand Total Lump Sum Amount: (Above items 5 and 6) (Please indicate this amount on the Tender Call Cover Page)

$_____________________

Substantial Performance project completion date will be no later than September 30, 2012.

4 of 99

Golder Associates Ltd.

2390 Argentia Road Mississauga, Ontario, Canada L5N 5Z7 Telephone: (905) 567-4444 Fax: (905) 567-6561

OFFICES ACROSS NORTH AMERICA, SOUTH AMERICA, EUROPE, AFRICA, ASIA AND AUSTRALASIA

REPORT ON

ASBESTOS BUILDING MATERIALS SURVEY

DUBLIN PUBLIC SCHOOL 819 SHEPPARD AVENUE WEST

SAP ID# 3088

Submitted to:

Toronto District School Board

Facility Services

15 Oakburn Crescent

Toronto, Ontario

M2N 2T5

DISTRIBUTION:

3 Copies - Toronto District School Board, Toronto, Ontario

2 Copies - Golder Associates Ltd., Mississauga, Ontario

March 2008 06-1113-212

5 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - i - 06-1113-212

Golder Associates

TABLE OF CONTENTS

1.0 INTRODUCTION ......................................................................................... 1 1.1 Scope of Work ....................................................................................... 1

2.0 METHODOLOGY ........................................................................................ 1 2.1 General Information ............................................................................... 1 2.2 Area Identification .................................................................................. 2 2.3 System Classification ............................................................................. 2 2.4 Asbestos Sampling and Analysis ........................................................... 3 2.5 Sampled and Presumed ACM Materials (PACM) ................................... 4 2.6 Existing Sample Data ............................................................................. 5 2.7 Condition of Material .............................................................................. 5 2.8 Accessibility of Material .......................................................................... 7 2.9 Response Actions .................................................................................. 8 2.10 Limitations of Survey .............................................................................. 9 2.11 General Recommendations .................................................................. 10

3.0 FINDINGS ................................................................................................. 11 3.1 Site-Specific Information ...................................................................... 11 3.2 Confirmed And Presumed ACM ........................................................... 12

4.0 RECOMMENDATIONS ............................................................................. 12 5.0 Limitations and Use of Report ................................................................... 12 6.0 CLOSURE ................................................................................................. 13 ATTACHMENT Abbreviations and Definitions

TABLES Table 1: Bulk Material Sampling Requirements Table 2: Specific Sampling and Assumption Criteria Table 3: Condition of Spray Applied Fireproofing, Thermal/Acoustic Insulation and Texture Finishes Table 4: Mechanical Insulation Table 5: Non-friable and Potentially Friable Material Table 6: Evaluation of ACM Debris Table 7: Accessibility Table 8: Response Actions Table 9: Action Matrix Table Table 10: Site-Specific Information

APPENDICES Appendix I: Figure SP: Site Location Plan Figure BA: ACM and Sample Location Plan (Basement) Figure 1: ACM and Sample Location Plan (Floor 1) Figure 2: ACM and Sample Location Plan (Floor 2) Appendix II: Laboratory Results Appendix III: Summary of All Asbestos-Containing Materials (ACM & PACM) Appendix IV: Room-by-Room Details: Summary Report by Location

6 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 1 - 06-1113-212

Golder Associates

1.0 INTRODUCTION

At the request of the Toronto District School Board (“TDSB”), Golder Associates Ltd. (“Golder”)

conducted a survey of Dublin Public School (the Site) to identify building materials that may

contain asbestos. The survey was performed with the objective of compiling an inventory of

asbestos-containing materials (ACMs) and providing recommendations to manage these materials

in accordance with Ontario Regulation 278/05, Regulation respecting Asbestos on Construction

Projects and in Buildings and Repair Operations, made under the Occupational Health and Safety

Act.

1.1 Scope of Work

Golder’s scope of work for this project included the following:

• A review of available Site information including Site plans and existing surveys as well as interviews with available personnel familiar with the Site;

• A Site reconnaissance and walk through (room-by-room) to identify suspect ACMs;

• Sample collection of suspected ACMs;

• Analysis of samples using an independent laboratory accredited by the National Voluntary Laboratory Accreditation Program (NVLAP);

• Transfer of information to eFacility database; and

• Preparation and delivery of a report identifying the presence, location and condition of ACMs (friable and non-friable) and, where necessary, recommendations for repair and or removal of damaged or deteriorated ACMs.

Where possible, Golder used existing reports and data detailing any previous findings related to ACMs.

2.0 METHODOLOGY

2.1 General Information

For the purposes of this survey, all materials used in the construction of the site are considered to

be building “components”. Each component, even those not suspected to contain asbestos, are

assigned a number and are addressed as one “homogeneous material” throughout a building.

Homogeneous Materials are defined by O. Reg. 278/05 as materials that are uniform in colour

and texture. A component number refers to a homogeneous material throughout its full extent,

even if its occurrence is not contiguous or physically connected.

7 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 2 - 06-1113-212

Golder Associates

2.2 Area Identification

The Site was typically assessed on a room-by-room or area-by-area basis. Each room or area was

then assigned a number. Collectively, rooms or areas are referred to as “areas” in this

assessment. Areas are typically defined as one room, but may include several interconnected

rooms or a portion of a room as identified on the attached drawings. Room or area numbers

provided by TDSB were generally utilized where they were provided. Not all numbers were

necessarily utilized and additional numbers were added as required to accurately delineate areas

for the purposes of collecting asbestos information.

2.3 System Classification

Areas were broken down into “systems” to document the materials present. Systems are used to

group various building materials, referred to as “Components”, into easily recognisable categories

which indicate where they are located. All Components are associated with a system (e.g., wall,

floor, piping, mechanical). The systems were broken down for each area as described below:

Floor: The floor or lower surface of an area. May include the roofing material in the “roof” area description. May not be present in areas such as vertical pipe chases or two-storey areas.

Wall : Walls or vertical perimeter of an area. May include the exterior walls for the “exterior” area of a Site. May not be present if area is defined as a portion of an area with no vertical perimeter surfaces.

Ceiling: An architectural or acoustical upper barrier or surface in an area which is typically suspended from, or attached to, the upper structural element (deck). May not be present in vertical shafts or where structural deck is exposed.

Structure: Structural element of the Site which usually refers to the concrete or metal upper deck, beams, columns or joists in an area or the fireproofing material applied to the surface of these materials.

Ductwork : Ducts and associated connectors which facilitate air movement between areas.

Piping Systems: Pipes which typically transport liquids and are commonly insulated. Does not include conduit for electrical services.

Mechanical Equipment: Boilers, chillers, hot water tanks, air handling units and other mechanical equipment typically present in mechanical rooms.

Other: Other items that don’t fit into the above categories including chalk boards, bench tops, window sealers or fire doors.

8 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 3 - 06-1113-212

Golder Associates

2.4 Asbestos Sampling and Analysis

The survey included a visual assessment of areas accessible at the time of the survey in order to

determine the type and extent of ACMs within the Site.

Bulk samples of each “homogeneous material” or “component” suspected to contain asbestos

were collected and submitted for laboratory analysis. The number of samples of each

“homogeneous material” was in accordance with Table 1 “Bulk Material Samples” of O. Reg.

278/05. Sample analysis of each “homogeneous material” was stopped at the first positive result.

Table 1 - Bulk Material Sampling Requirements

Type of material Size of area of homogeneous material Minimum

# of samples

Surfacing material, including without limitation material that is applied to surfaces by spraying, by troweling or otherwise. Examples include acoustical plaster on ceilings and fireproofing materials on structural members

Less than 90 square metres (969 square feet) 3 90 or more square metres, but less than 450 square metres (4,844 square feet) 5

450 or more square metres 7

Thermal insulation, except as described below

any size 3

Thermal insulation patch Less than 2 linear metres (6.6 linear feet) or 0.5 square metres (5.4 square feet) 1

Other material Any size 3

Sample collection consisted of obtaining a small volume of suspect material, placing it in an

individual plastic bag, and submitting it to an independent laboratory (International Asbestos

Testing Laboratories (IATL) of Mt. Laurel, N.J. or EMSL Analytical Inc of Westmount, N.J.) for

asbestos content analysis. Both labs are certified under The National Voluntary Laboratory

Accreditation Program (NVLAP) for Laboratory Proficiency. Samples were assigned a sample

number and series number to indicate how many samples of each homogeneous material, or

component, were collected. For example, the first sample of a component would be 3147-1-

3007-3171-01, where 3147 is the SAP ID#, 1 is the building at the Site (may be more than one),

3007 is a generic component code, 3171 is the component number, and 01 is the first sample of

this component. Samples of materials suspected of containing asbestos were submitted, along

with a chain of custody, to the lab for asbestos content analysis. The laboratory was instructed to

stop once a positive result (0.5% or greater) was obtained for any sample in a homogeneous

material group. Some samples may be identified by the laboratory to contain multiple phases or

layers which require separation and individual analysis of each separate phase or layer.

9 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 4 - 06-1113-212

Golder Associates

Samples were analyzed for asbestos type and percentage content using Polarized Light

Microscopy in accordance with U.S. Environmental Protection Agency (USEPA) methodologies

and dispersion staining techniques (EPA 600/R-93/116). Samples were analyzed to a minimum

detection limit of 0.5% to meet the requirements of O.Reg. 278/05. The identification of asbestos

fibres in bulk materials is based on a collective set of parameters dependent on the unique shape

and crystallographic properties of each fibre as viewed through the microscope. This method is

useful for the qualitative identification of asbestos and the semi-quantitative determination of

asbestos content in bulk materials expressed as a percent of projected area. The method identifies

types of asbestos and also measures percent of asbestos as perceived by the analyst in comparison

to standard area projections and the analyst’s experience. Analytical results are reported from

trace (less than the limit of detection), to the percentage counted or estimated. Materials reported

to contain less than 0.5% asbestos, including those referred to as less than the limit of detection

(<LOD), are not considered to be asbestos-containing under current regulations.

2.5 Sampled and Presumed ACM Materials (PACM)

For the purposes of this assessment, specific materials (components) have been designated as

“Presumed Asbestos-Containing Materials” (PACM) and have not been sampled. Materials

presumed to contain asbestos may also be referred to as “Assumed” or “Suspect” materials.

Other materials have been designated as requiring sampling wherever they were present. As

required by O.Reg. 278/05, all PACM shall be treated as ACM until appropriate sampling proves

otherwise. All references to ACM in this report shall include PACM unless specifically noted

otherwise. Specifically designated materials are presented in Table 2.

Table 2 - Specific Sampling and Assumption Criteria

Material Sampled Materials Presumed to Contain Asbestos (PACM) • ceiling tiles • pipe covering papers • texture coatings • textiles • pipe and other mechanical

insulation • sprayed fireproofing

• vinyl floor tile • vinyl sheet flooring • asbestos cement board • asbestos cement pipe • gaskets and packing • expansion joints • flex connections • roofing felts and sealers • putty. caulking, window glazing and mastics • friction materials • drywall joint compound • wall and ceiling plaster • concealed vermiculite • other suspect materials

10 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 5 - 06-1113-212

Golder Associates

2.6 Existing Sample Data

Existing bulk sampling information was obtained by Golder through reviewing existing surveys

or other information provided by TDSB. Where possible, Golder has relied on laboratory results

from previously collected samples, referred to as Historical Samples. Historical samples are

denoted in this report and it’s appendices by “-H” at the end of the sample number. In some

instances, final copies of the original laboratory reports were not available for review. In these

cases, the reported type and percentage of asbestos present may be approximate. This

information was used only if the surveyor, based on their experience with asbestos materials,

could clearly associate the historical sample information with the material (component) present at

the Site. Although historical sample information was used to confirm the presence of asbestos in

suspect materials, components were not deemed to be non-asbestos based on historical samples

unless they were of recent vintage and met all requirements outlined in O. Reg. 278/05. Existing

analytical data for materials that were analyzed to a detection limit of greater than 0.5% or

materials that could not be clearly linked to materials existing at the Site, as determined during

this survey, were not relied upon.

2.7 Condition of Material

Each ACM and PACM identified as part of this assessment was evaluated based on it’s condition.

The criteria used to assess the condition of a material, as defined by TDSB, are summarized in

Tables 3, 4, 5 and 6.

Table 3 - Condition of Spray Applied Fireproofing, Thermal/Acoustic Insulation and Texture Finishes

Good

Surface of material shows no significant signs of damage, deterioration or delamination. Good condition includes fireproofing or texture finishes that are not encapsulated or painted and where no delamination or damage is observed, and encapsulated fireproofing or texture finishes where the encapsulation has been applied after the damage or fallout occurred.

Poor Sprayed materials show signs of damage, delamination or deterioration. Significant delamination to surface of ACM spray.

The above table refers to evaluating the condition of ACM sprayed or trowelled fireproofing, sprayed or trowelled thermal/acoustic insulation (non-mechanical), or texture, decorative or acoustic finishes. In observation areas where damage exists in isolated locations, both good and poor condition may be applicable. The extent or percentage of each condition has been recorded. Fair condition has not been utilized in the evaluation of sprayed fireproofing or texture coat finishes The evaluation of ACM sprayed or trowelled fireproofing, sprayed or trowelled thermal insulation (non-mechanical), or texture, decorative or acoustic finishes which are present above ceilings, may be limited by building components such as ducts or full height walls that obstruct observations.

11 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 6 - 06-1113-212

Golder Associates

Table 4 - Mechanical Insulation

Good

Insulation is completely covered in jacketing and exhibits no evidence of damage or deterioration. No insulation is exposed. Includes conditions where the jacketing has minor damage (i.e., scuffs or stains), but the jacketing is not penetrated.

Fair

Minor penetrating damage to jacketed insulation (cuts, tears, nicks, deterioration or delamination) or undamaged insulation that had never been jacketed. Insulation is exposed but not showing surface disintegration. The extent of missing insulation ranges from minor to none. Damage can be repaired.

Poor Original insulation jacket is missing, damaged, deteriorated or delaminated. Insulation is exposed and significant areas have been dislodged. Damage cannot be readily repaired.

The evaluation of mechanical insulation may be limited by building components such as ducts or full height walls that obstruct observations. It is not possible to observe each foot of mechanical insulation from all angles.

Table 5 - Non-friable and Potentially Friable Material

Good No significant damage. Material may be cracked or broken but is stable and not likely to become friable upon casual contact. If there is no friable debris present, the condition is rated as good

Poor Material is severely damaged. Loose debris is present or binder has disintegrated to the point where the material has become friable.

The condition of non-friable or potentially friable ACM, such as ceiling tiles, drywall joint compound and plaster finishes containing asbestos and manufactured products such as asbestos cement products (Transite) have the potential to become friable when handled. Potentially Friable refers to ceiling tiles which can become friable very easily, vinyl sheet flooring with asbestos backing paper which can remain stuck to the substrate during removal of the vinyl, heavily deteriorated non-friable materials and wall plaster which is considered friable at the time of demolition. The evaluation of the condition of non-friable and potentially friable materials does not utilize a fair condition rating.

12 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 7 - 06-1113-212

Golder Associates

Table 6 - Evaluation of ACM Debris

Poor Debris from ACM (friable or non-friable) is inherently in a deteriorated state having become dislodged from the source material.

The presence of ACM debris is noted separately from the presumed ACM source and is referred to as debris. The identification of the exact location or presence of debris on the top of ceiling tiles is limited by the number of observations made and the presence of building components such as ducts or full height walls that obstruct observations. Note: Workers are advised to be watchful for the presence of debris when accessing or working in proximity to mechanical insulation or above ceilings in areas with ACM regardless of the reported presence or absence of debris.

2.8 Accessibility of Material

Materials are rated based on the ease with which they can be reached, and therefore physically

disturbed. The accessibility of materials known or suspected of being ACM is rated according to

the criteria presented in Table 7:

Table 7 - Accessibility

Access (A)

Materials within reach (from floor level) of all Site users. These also include materials in gymnasiums, workshops, and storage areas where activities of the Site users may result in disturbance of ACM not normally within reach from floor level. Visibility would typically be noted as “YES” for these items, except for under sinks, in closets, or other commonly accessed spaces.

Access (B)

Materials in frequently entered maintenance areas of the Site within reach of maintenance staff, without the need for a ladder. Includes materials within reach from a fixed ladder or catwalk (i.e., tops of equipment, mezzanines, and frequently entered pipe chases, tunnels and service areas). Visibility would typically be noted as “YES” for these items.

Access (C)

Materials above 8'-0" where use of a ladder is required to reach the ACM. Only includes ACM materials that are exposed to view without the removal or opening of other building components such as ceiling tiles, or service access doors or hatches. Does not include materials in infrequently accessed service areas of the Site. Visibility would be noted as “YES” for these items.

Access (D)

Materials that can not be reached without removing a building component, including lay-in ceilings or access panels in solid ceiling systems. Includes rarely entered crawl spaces, attic spaces, etc. Observations will be limited to the extent visible from access points. Visibility would be noted as “NO” for these items.

Access (E)

Materials behind inaccessible solid ceiling systems, walls or mechanical equipment, etc., where demolition of the ceiling, wall or equipment etc. is required to reach the ACM. These materials are visually identified by the surveyor, often with difficulty, and there may be uncertainty associated with them. Evaluation of condition and extent of ACM is limited or impossible, depending on the surveyor's ability to visually examine these materials. Visibility would be noted as “NO” for these items.

13 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 8 - 06-1113-212

Golder Associates

2.9 Response Actions

For each ACM or assumed ACM identified, a specific response action has been assigned. The

assigned response action is based on consideration of condition and accessibility. These actions

are based on the likely risk posed by the material. Damaged materials that are easily accessible

pose the greatest risk and good condition materials in inaccessible areas pose the least risk.

Response actions range from immediate clean-up of debris to ongoing routine inspections of non-

friable material in good condition.

In any building with friable asbestos, current regulations require implementation of an Asbestos

Management Program (AMP) which includes provisions for training and routine inspections of

ACM. As of November 1, 2007, these regulations will further require implementation of an AMP

for buildings containing non-friable ACM. Depending on the condition and the accessibility of

ACMs, more active measures such as repair or removal may be required. In the event of a

building alteration, it will be necessary to remove all ACM, regardless of condition, that is likely

to be disturbed by planned renovation, demolition or maintenance work. Response Actions and

their definitions are presented in Table 8.

Table 8 - Response Actions

Action 1

Immediate Clean-Up of Debris Restrict access that is likely to cause a disturbance of the ACM debris and clean up ACM debris immediately. The surveyor will immediately (within 24 hours) notify TDSB’s Environmental Coordinator of this condition.

Action 2

Type 2 Precautions for Entry into Areas with ACM Debris Restrict access to the area to persons utilizing Type 2 asbestos precautions as per O.Reg. 278/05. These precautions will be required until the ACM debris has been cleaned up, and the source of the debris has been stabilized or removed.

Action 3 ACM Removal Required for Compliance Remove ACM in compliance with regulatory requirements of O.Reg. 278/05.

Action 4 Type 2 Access into Areas Where ACM is Present and Likely to be Disturbed Use Type 2 asbestos precautions as per O.Reg. 278/05 when entry or access into an area is likely to disturb the ACM. .

Action 5 ACM Repair Repair ACM found in fair condition, and not likely to be damaged again or disturbed by normal use of the area or room.

Action 6 Routine Inspection Maintain routine inspection of ACM to monitor condition.

14 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 9 - 06-1113-212

Golder Associates

Based on the accessibility and action criteria presented above, the following Action Matrix Table,

Table 9, outlines appropriate action codes for all ACM and PACM identified.

Table 9 – Action Matrix Table

Access Condition

Debris Good Fair Poor

(A) Action 6 Action 5 Action 3 Action 1

(B) Action 6 Action 5 Action 3 Action 1

(C) Action 6 Action 5 Action 4 Action 2

(D) Action 6 Action 6 Action 4 Action 2

(E) Action 6 Action 6 Action 6 Action 6

2.10 Limitations of Survey

Only accessible areas of the Site were examined during our assessment. An accessible area is

defined as an area above a suspended ceiling tile, within a manufactured access hatch or behind a

closed door, not impeded by any structure, article or item. Ceiling spaces (between suspended

ceiling and structural deck) that were not accessible at the time of this assessment should be

considered to contain asbestos until proven otherwise. If these spaces are to be accessed for any

reason, such as a roof leak, etc., an inspection should be conducted by a competent person and

any suspect ACM should be sampled or presumed to contain asbestos. An enclosed area that

requires demolition to gain entry or a temporary access hatch that is not readily opened is

considered inaccessible. This report reflects the observations of accessed areas, and analytical

results of materials sampled during the survey.

Carpets were not removed to determine materials below as it is possible that asbestos materials

may be present under a portion of the carpeted area. Asbestos-containing flooring material

should be suspected below all carpets until proven otherwise. In addition, mastic associated with

any floor tiles or baseboards should be considered to contain asbestos until proven otherwise.

Similarly, equipment such as exhaust stacks and metal-clad breaching, boilers, kilns, electrical

components and mechanical piping and ducting were not disassembled for assessment.

Subsequently, materials such as refractory, gaskets and other internal components should be

considered suspect ACM until sampled and proven otherwise. Roofing components and building

envelope materials such as window caulking or glazing were not sampled and should be

presumed asbestos-containing until proven otherwise.

15 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 10 - 06-1113-212

Golder Associates

Analytical results reflect the sampled materials at the specific sample locations. Materials that

were visually similar in colour and texture were referenced to specific analyzed samples and were

considered to be of like composition and grouped as one homogeneous material.

Golder has relied on certain sample analysis results provided in documents supplied by TDSB

and prepared by others as detailed in Section 2.3 of this report.

Only suspect materials identified by TDSB and as detailed in Section 2.2 of this report were

sampled, with limited exceptions as determined by surveyors at the time of assessment.

2.11 General Recommendations

Should planned renovations involve the removal of materials confirmed or presumed to be

asbestos-containing, all appropriate precautions, as detailed in O. Reg. 278/05, must followed.

This survey was conducted to identify asbestos materials in accessible areas that require

monitoring as part of an Asbestos Management Program. It is possible that undiscovered ACMs

may be present within inaccessible locations such as wall cavities or above inaccessible ceilings.

Asbestos may also be present in materials that are inaccessible or not visible during a non-

invasive assessment. Materials such as adhesive mastic (may be used virtually anywhere) for

various items, including stick-up ceiling tiles, mirrors, etc., and packing compound in bell and

spigot joints of cast iron drain pipes may contain asbestos but are not easily confirmed without

causing significant damage to the associated materials. It is recommended that a more

comprehensive and invasive survey be conducted prior to any planned demolition or renovations

that involve entering previously inaccessible areas or inaccessible materials. If encountered

during future renovations or demolition, suspect materials should be treated as asbestos-

containing until proven otherwise.

If any ACM is present within the Site, an Asbestos Management Program (AMP) must be

maintained as per the requirements of Section 7 and 8 of O. Reg. 278/05. The AMP would

include provisions for regular assessments of all identified ACMs, appropriate procedures for

dealing with ACMs, and training, as appropriate, for all occupants who may come into contact

with ACMs.

16 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 11 - 06-1113-212

Golder Associates

3.0 FINDINGS

3.1 Site-Specific Information

Information relating to the assessment of this Site is presented in Table 10:

Table 10 – Site-Specific Information

DUBLIN PUBLIC SCHOOL SAP ID# 3088

Approximate Bldg. Size (ft2): 44, 950 # of Levels (floors) including basement(s): 3

Region: CS Use: Leased Out

Year of Construction: 1948 Additions (years of Construction): None

Surveyed By: Golder Associates Ltd. Survey Date(s): Nov. 2, 5, 6, 2007

The findings of this assessment have been summarized in tabular form and are presented in the

attached appendices. Floor plans indicating sample locations and mapping of confirmed ACMs

are presented in Appendix I. Location numbers are typically situated on a grey dot representing

the centroid of the area. If two numbers are too close together to be shown clearly, one number

will be moved to make for clear identification. These numbers are easily identified as they are

not on top of a grey dot but situated very close to them.

Please note that all materials may not be mapped on these plans. Also note that Golder has used

the numbers on drawings provided by TDSB where possible and added new numbers if

appropriate numbers describing the location were not available. Some of the numbers provided

by TDSB were not used by Golder in this survey (multiple numbers in one area, etc.) and are not

presented on Golder’s drawings. Similarly, some area location/room numbers, typically for roofs

and a limited number of other areas, are referenced on the drawings but do not have a room or

floor plan associated with them.

The location, quantity and extent of ACM has been identified throughout the Site based on the

findings during Golder’s information review and Site assessment. Following the sampling

protocol outlined in Section 2.1 of this report, a total of 23 samples were obtained of materials

suspected of containing asbestos from the Site and submitted, along with a chain of custody, for

asbestos content analysis. This number represents the total number of samples that were

collected and/or analysed, which may have included multiple layers of a particular material,

where each layer was considered a sample.

17 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 12 - 06-1113-212

Golder Associates

3.2 Confirmed And Presumed ACM

Confirmed and Presumed ACMs were identified within accessible areas of the Site. Floor plans

indicating sample locations and mapping of confirmed ACMs is presented in Appendix I.

Locations of historical samples, which were not collected during this assessment, are not shown

on the floor plans. Details of bulk sample analytical results (Laboratory Results) are presented in

Appendix II with listings of all ACMs (Summary of All Asbestos-Containing Materials, ACM &

PACM), presented in Appendix III. A listing of all materials identified, presented by location

(Room-by-Room Details: Summary Report by Location), is presented in Appendix IV.

4.0 RECOMMENDATIONS

Based on the findings of this assessment, actions have been assigned for each ACM identified.

Actions required for all ACMs are presented in the Summary of All Asbestos-Containing

Materials in Appendix III and the Room-by-Room Details, Summary Report by Location in

Appendix IV. All ACMs require routine inspection as indicated in TDSB Asbestos Management

Program and O. Reg. 278/05. All components (materials) identified in this report as ACM or

PACM should be considered as such wherever they are present within the building. Anyone

doing work at this site should be familiar with the contents of this report prior to conducting any

work that could disturb any building materials.

• An asbestos management program should be maintained for this facility as ACMs are

present;

• Inaccessible areas and spaces, such as above inaccessible ceilings or in wall or pipe

spaces, should be considered to contain asbestos until they can be accessed and properly

assessed;

• No Action Code 1 items requiring immediate remedial action were identified at this Site.

However, Priority 2 and 3 items were identified. Please refer to Appendix IV for details

and locations.

5.0 LIMITATIONS AND USE OF REPORT

The conclusions and recommendations contained in this assessment report are based upon

professional opinions with regard to the subject matter. These opinions are in accordance with

currently accepted industry practices for asbestos surveys and regulatory requirements for

sampling and identifying ACMs and are subject to the following inherent limitations:

18 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 13 - 06-1113-212

Golder Associates

1. The data and findings presented in this report are valid as of the date of the investigation. The passage of time, manifestation of latent conditions or occurrence of future events may warrant further exploration at the Site, analysis of the data, and re-evaluation of the findings, observations, and conclusions expressed in this report.

2. The data reported and the findings, observations, conclusions, and recommendations expressed in this report are limited by the Scope of Work. The Scope of Work was defined by the request of the client, the time and budgetary constraints imposed by the client, and availability of access to the Site.

3. Because of the limitations stated above, the findings, observations, conclusions, and recommendations expressed by Golder in this report are not, and should not be, considered an opinion concerning compliance of any past or present owner or operator of the Site with any federal, provincial or local laws or regulations.

4. No warranty or guarantee, whether expressed or implied, is made with respect to the data or the reported findings, observations, and conclusions, which are based solely upon Site conditions in existence at the time of investigation.

5. Golder will not be responsible for any real or perceived decrease in a property value, its saleability or ability to gain financing through the reporting of information in this report.

6. Golder’s assessment reports present professional opinions and findings of a scientific and technical nature. While attempts were made to relate the data and findings to applicable environmental and occupational health & safety laws and regulations, the report shall not be construed to offer legal opinion or representations as to the requirements of, nor compliance with, environmental and occupational health & safety laws, rules, regulations or policies of federal, provincial, or local governmental agencies. Any use of the assessment report constitutes acceptance of the limits of Golder’s liability. Golder’s liability extends only to its client and not to other parties who may obtain this assessment report. Issues raised by the report should be reviewed by appropriate legal counsel.

6.0 CLOSURE

We trust that this report meets your requirements. If you have any questions regarding the

content of this report, please do not hesitate to contact the undersigned.

GOLDER ASSOCIATES LTD.

Christopher Nielsen, B.Sc., CCEP

Manager, Environmental Health and Safety Group

19 of 99

Toronto District School Board March 2008

SAP ID# 3088 – Dublin PS - 14 - 06-1113-212

Golder Associates

Andreas Wagner, M.Eng., CIH, ROH Principal, Director, Environmental Health & Safety CLN/AW/ N:\Active\2006\1113\06-1113-212 TDSB-Asbestos Survey-Toronto\Reports\9_Final_Report_PDF\3088\ProjectWork\Final Report\06-1113-212 RPT 08MAR26 3088 Dublin PS Final.doc

20 of 99

Golder Associates

ATTACHMENT

ABBREVIATIONS AND DEFINITIONS

21 of 99

Golder Associates

ABBREVIATIONS AND DEFINITIONS

Abbreviations: SM, MED, LG Small, Medium and Large, respectively

<LOD Less than the Limit of Detection for the Analytical Method used. Typically 0.5% or 0.25%, or may indicate that no asbestos was identified in sample.

“ – “ Not applicable or no information required for this cell. When present under “Asbestos Type” column in Appendix IV, indicates that corresponding material is not considered to be asbestos-containing.

ACM Asbestos-Containing Material, defined as material that contains 0.5% or more asbestos by dry weight

FTG Fitting on a mechanical system including elbow, tee joint, valve, joint or end.

N/A Not Applicable

TBD To Be Determined

PACM Presumed Asbestos-Containing Material – must be treated as ACM until proven otherwise through bulk sample analysis

PLM Polarized Light Microscopy (asbestos identification procedure)

RND Round

SPF Spray-applied fireproofing

STR Straight section of pipe, duct or other mechanical system

VFT Vinyl Floor Tile

VSF Vinyl Sheet Flooring

Definitions:

Accessibility – A Accessible to anyone

Accessibility – B Accessible without a ladder

Accessibility – C Above eight feet and visible

Accessibility – D Above eight feet and not visible

Accessibility – E Inaccessible

Action Code – 1 Restrict access that is likely to cause a disturbance of the ACM debris and clean up ACM debris immediately

Action Code – 2 Restrict access to the area to persons using Type 2 precautions in accordance with O. Reg. 278/05 until the ACM debris has been cleaned up and the source of the debris has been stabilized or removed

Action Code – 3 Remove ACM in compliance with O. Reg. 278/05

Action Code – 4 Use Type 2 asbestos precautions in accordance with O. Reg. 278/05 when entry or access into an area is likely to disturb ACM

Action Code – 5 Repair ACM found in fair condition and not likely to be damaged again, or disturbed by normal use of the area or room

Action Code – 6 Maintain routine inspection of ACM

Asbestos Fibrous silicate materials including actinolite, amosite, anthophyllite, chrysotile, crocidolite and tremolite as defined in O. Reg. 278/05, s.1(2).

Asbestos I Primary type, by %, of asbestos present in a sample, as presented in the Laboratory Results Appendix

Asbestos II Secondary type, by percentage, of asbestos present in a sample, as presented in the Laboratory Results Appendix

Component Construction material used in building which is deemed to be a homogeneous material (consistent in colour and texture) and is treated as a unit throughout its extent within the building (e.g., plaster, concrete, or parging cement)

Homogeneous Material Homogeneous Materials are materials that are uniform in colour and texture and includes the material throughout its full extent, even if its occurrence is not contiguous or physically connected.

To Be Determined To be determined (TBD) through the inspection and sampling protocol, as required by O.Reg 278/05, for those areas that were not accessible during the initial survey. ACM is presumed to be present unless proven otherwise through sampling and accredited lab analysis and reports.

Not Applicable System is not present or no suspect material is associated with the system at the location

Not Found System or suspect material associated with it was not found to be present

Not Tested or

Sample Not Analyzed Previous sample of this homogeneous material was found to be positive for asbestos; therefore further analysis is not required.

22 of 99

Golder Associates

APPENDIX I

FLOOR PLANS WITH SAMPLE LOCATIONS AND ACM MAPPING

23 of 99

Base Data - CANMAP v2005.4Datum: NAD 83 Projection: UTM Zone 17N

REFERENCE

SITE LOCATION PLAN3088 - DUBLIN PS819 SHEPPARD AVENUE WESTTORONTO, ONTARIO

FIGURE: SPPROJECT No. 06-1113-212PROJECT

TITLE

ASBESTOS SURVEY - CENTRAL SERVICES REGIONTORONTO DISTRICT SCHOOL BOARD

"

REINER RD

SEARLE AVE

CODSELL AVE

WATERLOO AVE

BRIGHTON AVE

SHEPPARD AVE W

ACTON AVE

MCALLISTER RD

GODDARD ST

ELDER ST

MAXWELL ST

COCKSFIELD AVE

WILMINGTON AVE

FAYWOOD BLVD

ALEXIS BLVD

ALMORE AVE

BRYANT ST

BAINBRIDGE AVE

WILSON HEIGHTS BLVD

COMBE AVE

SANDALE GDNS

HARLOCK BLVD

GRANITE ST

NORCROSS RD

MARWILL ST

BOWRING WALK

DUNSMORE GDNS

SHAFTESBURY ST

FINDLAY BLVD

AMBASSADOR PL

AMOS CRES

BAINTREE CRT

LIBERATO CRT

DEHAVILAND STCOCKSFIELD AVE

³

LEGEND0 500 1,000 1,500250

Feet" Site Location

Express WayArterial RoadLocal road

SITE LOCATION

24 of 99

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!

!

!

!

!!

!

!!

!

!

!

!

!

A

A

A

A

69432-1

69425-1 69432

69431

6942869427

69425

69424

69423

69421

3088-1-5005-008-05

3088-1-5005-008-04

3088-1-5005-008-01,02,03

3088-1-3006-015-01,02,03

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!

!

!

!

!!

!

!!

!

!

!

!

!

A

A

A

A

69432-1

69425-1 69432

69431

6942869427

69425

69424

69423

69421

3088-1-5005-008-05

3088-1-5005-008-04

3088-1-5005-008-01,02,03

3088-1-3006-015-01,02,03

PROJECT

TITLE

Drawings based on plans provided by the Toronto District School Board.REFERENCE

0 2512.5Feet

G:\P

rojec

ts\20

06\06

-1113

-212_

TDSB

\GIS

\MXD

s\Draf

t\auto

\batch

\A_3

088_

1_-1.

mxd

ACM AND SAMPLE LOCATION PLANBASEMENT3088 - DUBLIN PS819 SHEPPARD AVENUE WESTTORONTO, ONTARIO

ASBESTOS SURVEY - CENTRAL SERVICES REGIONTORONTO DISTRICT SCHOOL BOARD FIGURE: BA

PROJECT No. 06-1113-212

1. This drawing is schematic only and is to be read in conjunction with theaccompanying text.2. Some numbers provided by the Toronto District School Board have not been used.

NOTESRoof ID: 68443Exterior ID: 68443-1

³N

Description of Asbestos-Containing MaterialsPipe Insulation

!!

!!

!!

!!

!!

!!

!!

!!

!!

!!Mechanical System,Pipe Insulation

3.Only sampled materials and/or confirmed ACM is shown on the drawing. Shaded areas represent the presence of one or more Asbestos-Containing Material (ACM) component(s). Cross reference to Appendix IV -“Room by Room Details - Summary Report By Location” for specifics.

LEGENDLEGEND!A

!A

Sample #Positive Sample LocationSample #Negative Sample Location Not Tested Sample Location Sample #!A

Location/Room!

Location Description69421 Washroom - Girls, 11069423 Electrical Room, 10269424 Classroom, 10369425 Boiler / Furnace Room, Boiler

Room/10869425-1 Corridor, Corridor 101

69427 Storage Room, 10969428 Caretakers Office, Caretaker/10769431 Classroom, 10469432 Washroom - Boys, 106

69432-1 Main Water Entry, 105

Sample # Location Component # Description3088-1-3006-015-01,02,03

69424 15 1x1 uniform small holes Glue On Ceiling Tiles

3088-1-5005-008-01,02,03

69425 8 Cellulose On Straight Run Pipe

3088-1-5005-008-04 69427 8 Cellulose On Straight Run Pipe3088-1-5005-008-05 69432 8 Cellulose On Straight Run Pipe

25 of 99

!

!

!

!

!

!

!

!

!

!

!!

!

!

!

!

!

!

!

!!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!!

!

!

!

!

!

!

!

!

!

!

!

!

A

A

A

69220-1

69450-1

69443-1

69440-1

69449-169451-1

69219-1

69442-1

6945269451 69450

69449

69448

6944769446

69445

69444

6944369442

69441

6944069439

69438

69437

69436

6943569434

6923769236

69235

69234

69233

69232

69231

6923069229

69228 69227

69226

69225

69223

69222

69221

69220

69219

69218

69217

69216

3088-1-3006-024-01,02,03

3088-1-3006-045-01,02,03

3088-1-5006-046-01,02,03!

!

!

!

!

!

!

!

!

!

!!

!

!

!

!

!

!

!

!!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!!

!

!

!

!

!

!

!

!

!

!

!

!

A

A

A

69220-1

69450-1

69443-1

69440-1

69449-169451-1

69219-1

69442-1

6945269451 69450

69449

69448

6944769446

69445

69444

6944369442

69441

6944069439

69438

69437

69436

6943569434

6923769236

69235

69234

69233

69232

69231

6923069229

69228 69227

69226

69225

69223

69222

69221

69220

69219

69218

69217

69216

3088-1-3006-024-01,02,03

3088-1-3006-045-01,02,03

3088-1-5006-046-01,02,03

PROJECT

TITLE

Drawings based on plans provided by the Toronto District School Board.REFERENCE

0 25 50 75 10012.5Feet

G:\P

rojec

ts\20

06\06

-1113

-212_

TDSB

\GIS

\MXD

s\Draf

t\auto

\batch

\A_3

088_

1_1.m

xd

ACM AND SAMPLE LOCATION PLANFLOOR 13088 - DUBLIN PS819 SHEPPARD AVENUE WESTTORONTO, ONTARIO

ASBESTOS SURVEY - CENTRAL SERVICES REGIONTORONTO DISTRICT SCHOOL BOARD FIGURE: 1

PROJECT No. 06-1113-212

1. This drawing is schematic only and is to be read in conjunction with theaccompanying text.2. Some numbers provided by the Toronto District School Board have not been used.

NOTESRoof ID: 68443Exterior ID: 68443-1

³N

Description of Asbestos-Containing MaterialsPipe Insulation

3.Only sampled materials and/or confirmed ACM is shown on the drawing. Shaded areas represent the presence of one or more Asbestos-Containing Material (ACM) component(s). Cross reference to Appendix IV -“Room by Room Details - Summary Report By Location” for specifics.

LEGENDLEGEND!A

!A

Sample #Positive Sample LocationSample #Negative Sample Location Not Tested Sample Location Sample #!A

Location/Room!

Location Description69216 Office / Admin. Area, 21769217 Classroom, 22469218 Classroom, 21969219 Corridor, E-W outside Stair C

69219-1 Corridor, N-S outside room 21269220 Classroom, 220

69220-1 Stairwell, Stair B69221 Office / Admin. Area, 22169222 Classroom, 22269223 Classroom, 22369225 Kitchen, 22969226 Gym, Auditorium/22869227 Stairwell, Exit 22569228 Stairwell, Stair C69229 Washroom, adjoining room 22369230 Washroom, 222C69231 Vestibule, 222A69232 Corridor, N-S between exit 101 and

room 20969233 Main Office, Office69234 Storage Room, PE Equipment/22769235 Storage Room, 228A69236 Washroom, adjoining room 22369237 Washroom, 222B69434 Vestibule, 10169435 Office / Admin. Area, 10569436 Office / Admin. Area, 23269437 Storage Room, adjoining room 23269438 Office / Admin. Area, 23169439 Vestibule, between rooms 231 and 23269440 Classroom, 208

69440-1 Stairwell, west of corridor 20369441 Classroom, 20469442 Office / Admin. Area, adjacent to

room 20869442-1 Corridor, Corridor 203

69443 Classroom, 20669443-1 Stairwell, Stair A

69444 Classroom, 20569445 Office / Admin. Area, 20969446 Kitchen, 23069447 Classroom, 21169448 Classroom, 21269449 Washroom - Girls, 213A

69449-1 Vestibule, 21369450 Washroom - Boys, 216A

69450-1 Vestibule, 21669451 Washroom, Staff/215

69451-1 Maintenance Room, pipe chaseadjoining room 215

69452 Caretakers Room, 214 Sample # Location Component # Description3088-1-3006-024-01,02,03

69440-1 24 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

3088-1-3006-045-01,02,03

69219-1 45 1x1 random small fissures and pinholes Glue On Ceiling Tiles

3088-1-5006-046-01,02,03

69219 46 Cellulose & Tar Paper On Straight Run Pipe

26 of 99

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!

!

!

!

!

!

!

!

! !

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

A

A

69248-1

69244-169242-1

69241-1

69462-1

69253-1

69454-1

69464

69463

69462

6946169460

69459

69458

69457

6945669455

69454

69453

69261

6926069259

69258

69257

69256

69255

69254

69253

69252

69251

6925069249

69248

69247

6924669245

69244

69243

69242

69241

692406923969238

3088-1-3006-035-01,02,03

3088-1-3006-039-01,02,03

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!

!

!

!

!

!

!

!

! !

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

A

A

69248-1

69244-169242-1

69241-1

69462-1

69253-1

69454-1

69464

69463

69462

6946169460

69459

69458

69457

6945669455

69454

69453

69261

6926069259

69258

69257

69256

69255

69254

69253

69252

69251

6925069249

69248

69247

6924669245

69244

69243

69242

69241

692406923969238

3088-1-3006-035-01,02,03

3088-1-3006-039-01,02,03

PROJECT

TITLE

Drawings based on plans provided by the Toronto District School Board.REFERENCE

0 25 50 75 10012.5Feet

G:\P

rojec

ts\20

06\06

-1113

-212_

TDSB

\GIS

\MXD

s\Draf

t\auto

\batch

\A_3

088_

1_2.m

xd

ACM AND SAMPLE LOCATION PLANFLOOR 23088 - DUBLIN PS819 SHEPPARD AVENUE WESTTORONTO, ONTARIO

ASBESTOS SURVEY - CENTRAL SERVICES REGIONTORONTO DISTRICT SCHOOL BOARD FIGURE: 2

PROJECT No. 06-1113-212

1. This drawing is schematic only and is to be read in conjunction with theaccompanying text.2. Some numbers provided by the Toronto District School Board have not been used.

NOTESRoof ID: 68443Exterior ID: 68443-1

³N

Description of Asbestos-Containing MaterialsPipe Insulation

!!

!!

!!

!!

!!

!!

!!

!!

!!

!!Mechanical System,Pipe Insulation

3.Only sampled materials and/or confirmed ACM is shown on the drawing. Shaded areas represent the presence of one or more Asbestos-Containing Material (ACM) component(s). Cross reference to Appendix IV -“Room by Room Details - Summary Report By Location” for specifics.

LEGENDLEGEND!A

!A

Sample #Positive Sample LocationSample #Negative Sample Location Not Tested Sample Location Sample #!A

Location/Room!

Location Description69238 Storage Room, Stockroom/32569239 Washroom, Staff/32469240 Kitchen, 323A69241 Staff Room, Staff/323

69241-1 Corridor, outside room 32469242 Classroom, 305

69242-1 Stairwell, west of corridor 30169243 Classroom, 32669244 Teachers Workroom, Tutorial/304

69244-1 Corridor, Corridor 30169245 Washroom, 304A69246 Caretakers Room, 30369247 Classroom, 32769248 Classroom, 302

69248-1 Stairwell, Stair A69249 Caretakers Room, 30869250 Washroom - Girls, 30769251 Washroom - Boys, 31069252 Classroom, 31169253 Corridor, N-S outside room 312

69253-1 Corridor, E-W outside Stair C69254 Classroom, 31269255 Washroom, 314A69256 Teachers Workroom, 31469257 Hub Room, 31569258 Photocopy Room, 314B69259 Office / Admin. Area, 31769260 Caretakers Room, 31669261 Office / Admin. Area, Staff/318B69453 Teachers Workroom, 318A69454 Library, 318

69454-1 Stairwell, Stair C69455 Corridor, E-W outside room 31869456 Storage Room, 318C69457 Mechanical Room, 318D69458 Library, 31869459 Classroom, 31969460 Storage Room, 32069461 Mechanical Room, 32269462 Classroom, A321

69462-1 Stairwell, Stair C69463 Empty Room, 31369464 Computer Room, adjoining room 314

Sample # Location Component # Description3088-1-3006-035-01,02,03

69241 35 1x1 large fissures and pinholes Glue On Ceiling Tiles

3088-1-3006-039-01,02,03

69458 39 1x1 random medium and large holes Glue On Ceiling Tiles

27 of 99

Golder Associates

APPENDIX II

LABORATORY RESULTS

28 of 99

Date: 4/15/2008

Facility : 3088 - Dublin PS

Client : Toronto District School Board

Job Number : 06-1113-212Laboratory Results

Appendix II

Page: 1Golder Associates

Refer to Attachment for Definitions and Abbreviations

45 1x1 random small fissures and pinholes Glue On Ceiling Tiles

3088-1-3006-045-03

020706987-0015

2047589 69219-1 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

39 1x1 random medium and large holes Glue On Ceiling Tiles

3088-1-3006-039-03

020706987-0012

2047589 69458 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

45 1x1 random small fissures and pinholes Glue On Ceiling Tiles

3088-1-3006-045-01

020706987-0013

2047589 69219-1 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

45 1x1 random small fissures and pinholes Glue On Ceiling Tiles

3088-1-3006-045-02

020706987-0014

2047589 69219-1 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

39 1x1 random medium and large holes Glue On Ceiling Tiles

3088-1-3006-039-02

020706987-0011

2047589 69458 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

15 1x1 uniform small holes Glue On Ceiling Tiles

3088-1-3006-015-03

020706987-0003

2047589 69424 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

20 Preformed Block On Straight Run Pipe

3088-1-0000-20-01-H

3088-1-0000-20-01-H

N/A N/A N/A 50 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files

24 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

3088-1-3006-024-01

020706987-0004

2047589 69440-1 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

11 Aircell On Straight Run Pipe 3088-1-0000-11-01-H

3088-1-0000-11-01-H

N/A N/A N/A 75 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files

15 1x1 uniform small holes Glue On Ceiling Tiles

3088-1-3006-015-01

020706987-0001

2047589 69424 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

15 1x1 uniform small holes Glue On Ceiling Tiles

3088-1-3006-015-02

020706987-0002

2047589 69424 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

35 1x1 large fissures and pinholes Glue On Ceiling Tiles

3088-1-3006-035-02

020706987-0008

2047589 69241 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

35 1x1 large fissures and pinholes Glue On Ceiling Tiles

3088-1-3006-035-03

020706987-0009

2047589 69241 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

39 1x1 random medium and large holes Glue On Ceiling Tiles

3088-1-3006-039-01

020706987-0010

2047589 69458 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

24 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

3088-1-3006-024-02

020706987-0005

2047589 69440-1 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

24 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

3088-1-3006-024-03

020706987-0006

2047589 69440-1 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

35 1x1 large fissures and pinholes Glue On Ceiling Tiles

3088-1-3006-035-01

020706987-0007

2047589 69241 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

Building: 1 (Dublin PS)

Component Sample # Lab Sample #

Lab Report Number

Location Test Method

Asbestos I %

Asbestos I Type

Asbestos II %

Asbestos II Type

LOD %

Additional Comments

29 of 99

Date: 4/15/2008

Facility : 3088 - Dublin PS

Client : Toronto District School Board

Job Number : 06-1113-212Laboratory Results

Appendix II

Page: 2Golder Associates

Refer to Attachment for Definitions and Abbreviations

8 Cellulose On Straight Run Pipe 3088-1-5005-008-02

020706987-0017

2047589 69425 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

8 Cellulose On Straight Run Pipe 3088-1-5005-008-01

020706987-0016

2047589 69425 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

7 Parging Cement On Fittings 3088-1-5001-007-01-H

3088-1-5001-007-01-H

3088-1-5001-007-01-H

69425 N/A 75 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files

8 Cellulose On Straight Run Pipe 3088-1-5005-008-03

020706987-0018

2047589 69425 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

9 Parging Cement 3088-1-7005-009-01-H

3088-1-7005-009-01-H

3088-1-7005-009-01-H

69425 N/A 75 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files

8 Cellulose On Straight Run Pipe 3088-1-5005-008-05

020706987-0020

2047589 69432 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

8 Cellulose On Straight Run Pipe 3088-1-5005-008-04

020706987-0019

2047589 69427 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

46 Cellulose & Tar Paper On Straight Run Pipe

3088-1-5006-046-02

020706987-0022

2047589 69219 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

46 Cellulose & Tar Paper On Straight Run Pipe

3088-1-5006-046-01

020706987-0021

2047589 69219 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

48 Parging Cement On Seam, Joints And Pins

3088-1-0000-48-01-H

3088-1-0000-48-01-H

N/A N/A N/A 50 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files

46 Cellulose & Tar Paper On Straight Run Pipe

3088-1-5006-046-03

020706987-0023

2047589 69219 PLM <LOD No Asbestos Detected

N/A Not Tested 0.5 N/A

Building: 1 (Dublin PS)

Component Sample # Lab Sample #

Lab Report Number

Location Test Method

Asbestos I %

Asbestos I Type

Asbestos II %

Asbestos II Type

LOD %

Additional Comments

30 of 99

Golder Associates

APPENDIX III

SUMMARY OF ALL ASBESTOS-CONTAINING MATERIALS

(ACM & PACM)

31 of 99

Date: 4/15/2008

Facility : 3088 - Dublin PS

Client : Toronto District School Board

Job Number : 06-1113-212Summary of All Asbestos-Containing Materials

Appendix III - ACM & PACM

Golder Associates Page: 1

Refer to Attachment for Definitions and Abbreviations

18 Plaster No 69219-1;69220-1;69223;69454-1 WALL 102.00 square feet C Yes N/A Presumed 6

17 12" x 12" Vinyl Floor Tile No 69246;69260 FLOOR 33.00 square feet B Yes N/A Presumed 6

17 12" x 12" Vinyl Floor Tile No 69218;69220;69222;69238;69240;69241;69241-1;69242;69243;69244;69247;69248;69256;69258;69261;69424;69440;69441;69442;69443;69446;69447;69448;69453;69454;69455;69458;69460

FLOOR 14,763.00 square feet A Yes N/A Presumed 6

13 Bell & Spigot Joints Yes 69428 PIPING SYSTEMS 2 each C Yes N/A Presumed 6

13 Bell & Spigot Joints Yes 69246;69451-1;69461 PIPING SYSTEMS 31 each B Yes N/A Presumed 6

13 Bell & Spigot Joints Yes 68443-1;69234;69421;69432;69442 PIPING SYSTEMS 26 each A Yes N/A Presumed 6

12 Window Sealers Yes 69428 OTHER 2 each B Yes N/A Presumed 6

12 Window Sealers Yes 69217;69218;69219;69219-1;69220;69220-1;69222;69223;69225;69226;69227;69231;69233;69234;69238;69240;69241;69241-1;69242;69243;69244;69247;69248;69248-1;69250;69251;69252;69253;69254;69258;69261;69421;69424;69431;69432;69434;69435;69436;69437;69438;69440;69441;69442;69443;69444;69445;69446;69447;69448;69449;69454;69454-1;69455;69458;69459;69460;69462;69462-1

OTHER 316 each A Yes N/A Presumed 6

12 Window Sealers Yes 69216;69221;69242-1;69259;69457 OTHER 13 each C Yes N/A Presumed 6

11 Aircell On Straight Run Pipe Yes 69428 PIPING SYSTEMS 10.00 linear feet B Yes 75 Chrysotile 6

11 Aircell On Straight Run Pipe Yes 69427 PIPING SYSTEMS 10.00 linear feet A Yes 75 Chrysotile 3

11 Aircell On Straight Run Pipe Yes 69421 PIPING SYSTEMS 30.00 linear feet C Yes 75 Chrysotile 6

11 Aircell On Straight Run Pipe Yes 69219;69223 PIPING SYSTEMS 210.00 linear feet D No 75 Chrysotile 6

10 Other Suspect Piping Yes 69451-1 PIPING SYSTEMS 100.00 linear feet B Yes N/A Presumed 6

10 Other Suspect Piping Yes 69424;69425;69443 PIPING SYSTEMS 108.00 linear feet C Yes N/A Presumed 6

10 Other Suspect Piping Yes 69223;69229;69442 PIPING SYSTEMS 65.00 linear feet D No N/A Presumed 6

Building: 1 (Dublin PS)

Component Description of Material Friable Locations System Quantity Units Accessibility Visible Asbestos % Type Action Code

Component Details Asbestos Content

32 of 99

Date: 4/15/2008

Facility : 3088 - Dublin PS

Client : Toronto District School Board

Job Number : 06-1113-212Summary of All Asbestos-Containing Materials

Appendix III - ACM & PACM

Golder Associates Page: 2

Refer to Attachment for Definitions and Abbreviations

34 Drywall And Joint Compound No 69216;69229;69230;69235;69236;69237;69238;69239;69240;69255;69257;69259;69260;69449;69450;69451;69456

CEILING 1,398.00 square feet C Yes N/A Presumed 6

33 Drywall And Joint Compound No 69246 WALL 60.00 square feet B Yes N/A Presumed 6

33 Drywall And Joint Compound No 69218;69220;69243;69244;69245;69247;69248;69261;69453;69454

WALL 1,139.00 square feet A Yes N/A Presumed 6

32 Vinyl Countertop Yes 69225;69242;69243;69244;69247;69248;69252;69254;69448;69459;69462

OTHER 250.00 square feet A Yes N/A Presumed 6

30 Vinyl Sheet Flooring Yes 69225;69242;69243;69245;69247;69248;69445 FLOOR 1,997.00 square feet A Yes N/A Presumed 6

29 Transite Asbestos Cement No 69232;69434 WALL 80.00 square feet A Yes N/A Presumed 6

29 Transite Asbestos Cement No 69222;69223 WALL 210.00 square feet E No N/A Presumed 6

29 Transite Asbestos Cement No 68443-1;69227 WALL 720.00 square feet C Yes N/A Presumed 6

27 Horizontal Plaster Bulkhead No 69442 OTHER 60.00 square feet A Yes N/A Presumed 6

27 Horizontal Plaster Bulkhead No 69440;69441;69443;69444 OTHER 560.00 square feet C Yes N/A Presumed 6

26 Plaster No 69442 CEILING 187.00 square feet D No N/A Presumed 6

26 Plaster No 69220-1;69253 CEILING 127.00 square feet A Yes N/A Presumed 6

21 9" x 9" Vinyl Floor Tile No 69216;69217;69221;69223;69233;69235;69252;69254;69255;69256;69257;69258;69259;69431;69435;69436;69437;69438;69439;69444;69456;69459;69460;69462;69463;69464

FLOOR 8,658.00 square feet A Yes N/A Presumed 3

20 Preformed Block On Straight Run Pipe

Yes 69432 PIPING SYSTEMS 40.00 linear feet A Yes 50 Chrysotile 6

20 Preformed Block On Straight Run Pipe

Yes 69421 PIPING SYSTEMS 30.00 linear feet C Yes 50 Chrysotile 6

18 Plaster No 69260 WALL 95.00 square feet B Yes N/A Presumed 6

18 Plaster No 69229;69230;69236;69237;69238;69239;69240;69241;69241-1;69242-1;69244;69244-1;69248-1;69253;69253-1;69255;69256;69257;69258;69425-1;69440;69440-1;69441;69442;69442-1;69443;69443-1;69444;69463;69464

WALL 10,903.00 square feet A Yes N/A Presumed 6

Building: 1 (Dublin PS)

Component Description of Material Friable Locations System Quantity Units Accessibility Visible Asbestos % Type Action Code

Component Details Asbestos Content

33 of 99

Date: 4/15/2008

Facility : 3088 - Dublin PS

Client : Toronto District School Board

Job Number : 06-1113-212Summary of All Asbestos-Containing Materials

Appendix III - ACM & PACM

Golder Associates Page: 3

Refer to Attachment for Definitions and Abbreviations

9 Parging Cement Yes 69425 MECHANICAL EQUIPMENT

150.00 square feet B Yes 75 Chrysotile 6

7 Parging Cement On Fittings Yes 69424;69425-1;69440;69442-1;69443;69444 PIPING SYSTEMS 58 each C Yes 75 Chrysotile 6

7 Parging Cement On Fittings Yes 69423;69425;69428;69432-1;69457 PIPING SYSTEMS 192 each B Yes 75 Chrysotile 6

7 Parging Cement On Fittings Yes 69221;69234;69421;69427;69431;69432;69440-1;69441;69442;69443-1;69456

PIPING SYSTEMS 264 each A Yes 75 Chrysotile 6

7 Parging Cement On Fittings Yes 69219;69223;69229;69237;69455 PIPING SYSTEMS 62 each D No 75 Chrysotile 2

52 Built Up Membrane Roof No 68443 FLOOR 22,000.00 square feet B Yes N/A Presumed 6

48 Parging Cement On Seam, Joints And Pins

Yes 69457 DUCTWORK 25.00 square feet C Yes 50 Chrysotile 6

47 Perforated Transite Asbestos Cement

No 69457 WALL 180.00 square feet B Yes N/A Presumed 6

43 Transite Asbestos Cement No 68443-1;69227 CEILING 400.00 square feet C Yes N/A Presumed 6

42 Plaster Column Enclosure No 69223 STRUCTURE 36.00 square feet A Yes N/A Presumed 6

40 Vertical Drywall Bulkhead No 69453;69458 OTHER 85.00 square feet A Yes N/A Presumed 6

38 Horizontal Drywall Bulkhead No 69257 OTHER 20.00 square feet C Yes N/A Presumed 6

36 Vertical Plaster Bulkhead No 69241;69463 OTHER 35.00 square feet A Yes N/A Presumed 6

Building: 1 (Dublin PS)

Component Description of Material Friable Locations System Quantity Units Accessibility Visible Asbestos % Type Action Code

Component Details Asbestos Content

34 of 99

Golder Associates

APPENDIX IV

ROOM-BY-ROOM DETAILS

SUMMARY REPORT BY LOCATION

35 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 1Golder Associates

Refer to Attachment for Definitions and Abbreviations

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 10 0 0 0 10 each 75 Chrysotile Yes Yes B 6

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

WALL Concrete 3 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Basement: 69423 Quantity/Condition Total Location Details: Electrical Room, 102 (Open)

CEILING Not Found 1 - - - - - - - - - - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

PIPING SYSTEMS Aircell On Straight Run Pipe 11 30.00 0.00 0.00 0.00 30.00 linear feet 75 Chrysotile Yes Yes C 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Concrete 3 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 90 0 0 0 90 each 75 Chrysotile Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6

PIPING SYSTEMS Bell & Spigot Joints 13 1 0 0 0 1 each - Presumed Yes Yes A 6

PIPING SYSTEMS Preformed Block On Straight Run Pipe 20 30.00 0.00 0.00 0.00 30.00 linear feet 50 Chrysotile Yes Yes C 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Basement: 69421 Quantity/Condition Total Location Details: Washroom - Girls, 110 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

36 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 2Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING Not Found 1 - - - - - - - - - - - -

WALL Brick/Block/Concrete 5 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

Location: Basement: 69425 Quantity/Condition Total Location Details: Boiler / Furnace Room, Boiler Room/108 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

PIPING SYSTEMS Parging Cement On Fittings 7 7 0 0 0 7 each 75 Chrysotile Yes Yes C 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING 1x1 uniform small holes Glue On Ceiling Tiles 15 - - - - - - <LOD No Asbestos Detected

- - - -

CEILING New Ceiling Tile 16 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 788.00 0.00 0.00 0.00 788.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

WALL Concrete 3 - - - - - - - - - - - -

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

PIPING SYSTEMS Other Suspect Piping 10 3.00 0.00 0.00 0.00 3.00 linear feet - Presumed Yes Yes C 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Basement: 69424 Quantity/Condition Total Location Details: Classroom, 103 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

Location: Basement: 69423 Quantity/Condition Total Location Details: Electrical Room, 102 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

37 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 3Golder Associates

Refer to Attachment for Definitions and Abbreviations

PIPING SYSTEMS Parging Cement On Fittings 7 35 0 0 0 35 each 75 Chrysotile Yes Yes C 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Plaster 18 50.00 0.00 0.00 0.00 50.00 square feet

- Presumed No Yes A 6

FLOOR Concrete 3 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

Location: Basement: 69425-1 Quantity/Condition Total Location Details: Corridor, Corridor 101 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 120 0 0 0 120 each 75 Chrysotile Yes Yes B 6

PIPING SYSTEMS Other Suspect Piping 10 100.00 0.00 0.00 0.00 100.00 linear feet - Presumed Yes Yes C 6

STRUCTURE Concrete 3 - - - - - - - - - - - -

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected

- - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Parging Cement 9 150.00 0.00 0.00 0.00 150.00 square feet

75 Chrysotile Yes Yes B 6

MECHANICAL EQUIPMENT

Uninsulated 2 - - - - - - - - - - - -

Comments: Includes location 69426.

Location: Basement: 69425 Quantity/Condition Total Location Details: Boiler / Furnace Room, Boiler Room/108 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

38 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 4Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING Not Found 1 - - - - - - - - - - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

WALL Concrete 3 - - - - - - - - - - - -

PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected

- - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 25 0 0 0 25 each 75 Chrysotile Yes Yes B 6

PIPING SYSTEMS Aircell On Straight Run Pipe 11 10.00 0.00 0.00 0.00 10.00 linear feet 75 Chrysotile Yes Yes B 6

PIPING SYSTEMS Bell & Spigot Joints 13 2 0 0 0 2 each - Presumed Yes Yes C 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Basement: 69428 Quantity/Condition Total Location Details: Caretakers Office, Caretaker/107 (Open)

STRUCTURE Concrete 3 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected

- - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Aircell On Straight Run Pipe 11 9.00 0.00 1.00 0.00 10.00 linear feet 75 Chrysotile Yes Yes A 3

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 20 0 0 0 20 each 75 Chrysotile Yes Yes A 6

Location: Basement: 69427 Quantity/Condition Total Location Details: Storage Room, 109 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

39 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 5Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR Concrete 3 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Concrete 3 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

Location: Basement: 69432 Quantity/Condition Total Location Details: Washroom - Boys, 106 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

CEILING New Ceiling Tile 16 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING 1x1 uniform small holes Glue On Ceiling Tiles 15 - - - - - - <LOD No Asbestos Detected

- - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 772.00 0.00 0.00 0.00 772.00 square feet

- Presumed No Yes A 6

WALL Concrete 3 - - - - - - - - - - - -

OTHER Window Sealers 12 5 0 0 0 5 each - Presumed Yes Yes A 6

PIPING SYSTEMS Parging Cement On Fittings 7 20 0 0 0 20 each 75 Chrysotile Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Basement: 69431 Quantity/Condition Total Location Details: Classroom, 104 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes B 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Basement: 69428 Quantity/Condition Total Location Details: Caretakers Office, Caretaker/107 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

40 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 6Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Concrete 3 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 12 0 0 0 12 each 75 Chrysotile Yes Yes B 6

WALL Concrete 3 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Basement: 69432-1 Quantity/Condition Total Location Details: Main Water Entry, 105 (Open)

PIPING SYSTEMS Preformed Block On Straight Run Pipe 20 40.00 0.00 0.00 0.00 40.00 linear feet 50 Chrysotile Yes Yes A 6

PIPING SYSTEMS Bell & Spigot Joints 13 7 0 0 0 7 each - Presumed Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 4 0 0 0 4 each - Presumed Yes Yes A 6

PIPING SYSTEMS Parging Cement On Fittings 7 50 0 0 0 50 each 75 Chrysotile Yes Yes A 6

PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected

- - - -

Comments: Includes locations 69430, 69433, and 69429.

Location: Basement: 69432 Quantity/Condition Total Location Details: Washroom - Boys, 106 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

41 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 7Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 706.00 0.00 0.00 0.00 706.00 square feet

- Presumed No Yes A 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Location: Floor 1: 69217 Quantity/Condition Total Location Details: Classroom, 224 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

WALL Brick 22 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 123.00 0.00 0.00 0.00 123.00 square feet

- Presumed No Yes C 6

FLOOR 9" x 9" Vinyl Floor Tile 21 123.00 0.00 0.00 0.00 123.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes C 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69216 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 217 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

42 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 8Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

Location: Floor 1: 69219 Quantity/ConditionTotal

Location Details: Corridor, E-W outside Stair C (Limited view above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Drywall And Joint Compound 33 50.00 0.00 0.00 0.00 50.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 845.00 0.00 0.00 0.00 845.00 square feet

- Presumed No Yes A 6

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69218 Quantity/Condition Total Location Details: Classroom, 219 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access beneath sink due to storage.

Location: Floor 1: 69217 Quantity/Condition Total Location Details: Classroom, 224 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

43 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 9Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

CEILING 1x1 random small fissures and pinholes Glue On Ceiling Tiles

45 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Plaster 18 20.00 0.00 0.00 0.00 20.00 square feet

- Presumed No Yes C 6

WALL Concrete Block 4 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69219-1 Quantity/ConditionTotal

Location Details: Corridor, N-S outside room 212 (No access above ceiling)

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

PIPING SYSTEMS Aircell On Straight Run Pipe 11 200.00 0.00 0.00 0.00 200.00 linear feet 75 Chrysotile Yes No D 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

PIPING SYSTEMS Cellulose & Tar Paper On Straight Run Pipe 46 - - - - - - <LOD No Asbestos Detected

- - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

PIPING SYSTEMS Parging Cement On Fittings 7 10 2 0 0 12 each 75 Chrysotile Yes No D 6

PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected

- - - -

Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling space, suspect that ACMs may be present.

Location: Floor 1: 69219 Quantity/ConditionTotal

Location Details: Corridor, E-W outside Stair C (Limited view above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

44 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 10Golder Associates

Refer to Attachment for Definitions and Abbreviations

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

WALL Drywall And Joint Compound 33 50.00 0.00 0.00 0.00 50.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 839.00 0.00 0.00 0.00 839.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69220 Quantity/Condition Total Location Details: Classroom, 220 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Window Sealers 12 4 0 0 0 4 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69219-1 Quantity/ConditionTotal

Location Details: Corridor, N-S outside room 212 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

45 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 11Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 295.00 0.00 0.00 0.00 295.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 5 0 0 0 5 each 75 Chrysotile Yes Yes A 6

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69221 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 221 (No access above ceiling)

CEILING Plaster 26 100.00 0.00 0.00 0.00 100.00 square feet

- Presumed No Yes A 6

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Plaster 18 8.00 0.00 0.00 0.00 8.00 square feet

- Presumed No Yes C 6

WALL Concrete Block 4 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69220-1 Quantity/Condition Total Location Details: Stairwell, Stair B (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

46 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 12Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 1108.00 0.00 0.00 0.00 1108.00 square feet

- Presumed No Yes A 6

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

WALL Transite Asbestos Cement 29 105.00 0.00 0.00 0.00 105.00 square feet

- Presumed No No E 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69222 Quantity/Condition Total Location Details: Classroom, 222 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes C 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69221 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 221 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

47 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 13Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR Vinyl Sheet Flooring 30 102.00 0.00 0.00 0.00 102.00 square feet

- Presumed Yes Yes A 6

WALL Wood 14 - - - - - - - - - - - -

Location: Floor 1: 69225 Quantity/Condition Total Location Details: Kitchen, 229 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Aircell On Straight Run Pipe 11 10.00 0.00 0.00 0.00 10.00 linear feet 75 Chrysotile Yes No D 6

PIPING SYSTEMS Parging Cement On Fittings 7 28 0 2 3 33 each 75 Chrysotile Yes No D 2

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

WALL Transite Asbestos Cement 29 105.00 0.00 0.00 0.00 105.00 square feet

- Presumed No No E 6

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Plaster 18 66.00 0.00 0.00 0.00 66.00 square feet

- Presumed No Yes C 6

FLOOR 9" x 9" Vinyl Floor Tile 21 844.00 0.00 1.00 0.00 845.00 square feet

- Presumed No Yes A 3

FLOOR Carpet 41 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

STRUCTURE Wood 14 - - - - - - - - - - - -

STRUCTURE Plaster Column Enclosure 42 36.00 0.00 0.00 0.00 36.00 square feet

- Presumed No Yes A 6

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

PIPING SYSTEMS Other Suspect Piping 10 50.00 0.00 0.00 0.00 50.00 linear feet - Presumed Yes No D 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69223 Quantity/Condition Total Location Details: Classroom, 223 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

48 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 14Golder Associates

Refer to Attachment for Definitions and Abbreviations

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 15 0 0 0 15 each - Presumed Yes Yes A 6

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

WALL Brick 22 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

FLOOR Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69226 Quantity/Condition Total Location Details: Gym, Auditorium/228 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Vinyl Countertop 32 50.00 0.00 0.00 0.00 50.00 square feet

- Presumed Yes Yes A 6

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69225 Quantity/Condition Total Location Details: Kitchen, 229 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

49 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 15Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Concrete 3 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69228 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

CEILING Transite Asbestos Cement 43 40.00 0.00 0.00 0.00 40.00 square feet

- Presumed No Yes C 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Transite Asbestos Cement 29 20.00 0.00 0.00 0.00 20.00 square feet

- Presumed No Yes C 6

WALL Concrete Block 4 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69227 Quantity/Condition Total Location Details: Stairwell, Exit 225 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

50 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 16Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR Ceramic 25 - - - - - - - - - - - -

Location: Floor 1: 69230 Quantity/Condition Total Location Details: Washroom, 222C (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 12.00 0.00 0.00 0.00 12.00 square feet

- Presumed No Yes C 6

STRUCTURE Metal 23 - - - - - - - - - - - -

FLOOR Ceramic 25 - - - - - - - - - - - -

WALL Plaster 18 24.00 0.00 0.00 0.00 24.00 square feet

- Presumed No Yes A 6

WALL Ceramic 25 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 8 0 1 1 10 each 75 Chrysotile Yes No D 2

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

PIPING SYSTEMS Other Suspect Piping 10 10.00 0.00 0.00 0.00 10.00 linear feet - Presumed Yes No D 6

Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69229 Quantity/ConditionTotal

Location Details: Washroom, adjoining room 223 (Limited view above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access beneath stairs due to storage.

Location: Floor 1: 69228 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

51 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 17Golder Associates

Refer to Attachment for Definitions and Abbreviations

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Window Sealers 12 4 0 0 0 4 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69231 Quantity/Condition Total Location Details: Vestibule, 222A (No access above ceiling)

CEILING Drywall And Joint Compound 34 10.00 0.00 0.00 0.00 10.00 square feet

- Presumed No Yes C 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Plaster 18 24.00 0.00 0.00 0.00 24.00 square feet

- Presumed No Yes A 6

WALL Ceramic 25 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69230 Quantity/Condition Total Location Details: Washroom, 222C (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

52 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 18Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 767.00 0.00 0.00 0.00 767.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected

- - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69233 Quantity/Condition Total Location Details: Main Office, Office (No access above ceiling)

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

WALL Transite Asbestos Cement 29 50.00 0.00 0.00 0.00 50.00 square feet

- Presumed No Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69232 Quantity/ConditionTotal

Location Details: Corridor, N-S between exit 101 and room 209 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

53 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 19Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 104.00 0.00 0.00 0.00 104.00 square feet

- Presumed No Yes C 6

WALL Brick 22 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 104.00 0.00 0.00 0.00 104.00 square feet

- Presumed No Yes A 6

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69235 Quantity/Condition Total Location Details: Storage Room, 228A (No access above ceiling)

STRUCTURE Concrete 3 - - - - - - - - - - - -

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

PIPING SYSTEMS Bell & Spigot Joints 13 11 0 0 0 11 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 15 0 0 0 15 each 75 Chrysotile Yes Yes A 6

Location: Floor 1: 69234 Quantity/Condition Total Location Details: Storage Room, PE Equipment/227 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to wall hatch; painted shut.

Location: Floor 1: 69233 Quantity/Condition Total Location Details: Main Office, Office (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

54 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 20Golder Associates

Refer to Attachment for Definitions and Abbreviations

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

WALL Plaster 18 24.00 0.00 0.00 0.00 24.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Ceramic 25 - - - - - - - - - - - -

FLOOR Ceramic 25 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 10.00 0.00 0.00 0.00 10.00 square feet

- Presumed No Yes C 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69236 Quantity/ConditionTotal

Location Details: Washroom, adjoining room 223 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. Limited access due to storage.

Location: Floor 1: 69235 Quantity/Condition Total Location Details: Storage Room, 228A (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

55 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 21Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Transite Asbestos Cement 29 30.00 0.00 0.00 0.00 30.00 square feet

- Presumed No Yes A 6

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Brick 22 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69434 Quantity/Condition Total Location Details: Vestibule, 101 (No access above ceiling)

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 10.00 0.00 0.00 0.00 10.00 square feet

- Presumed No Yes C 6

STRUCTURE Metal 23 - - - - - - - - - - - -

FLOOR Ceramic 25 - - - - - - - - - - - -

WALL Plaster 18 24.00 0.00 0.00 0.00 24.00 square feet

- Presumed No Yes A 6

WALL Ceramic 25 - - - - - - - - - - - -

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 1 0 0 1 2 each 75 Chrysotile Yes No D 2

Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling space, suspect that ACMs may be present.

Location: Floor 1: 69237 Quantity/Condition Total Location Details: Washroom, 222B (Limited view above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

56 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 22Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 119.00 0.00 2.00 0.00 121.00 square feet

- Presumed No Yes A 3

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69436 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 232 (No access above ceiling)

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 111.00 0.00 0.00 0.00 111.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69435 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 105 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69434 Quantity/Condition Total Location Details: Vestibule, 101 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

57 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 23Golder Associates

Refer to Attachment for Definitions and Abbreviations

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 42.00 0.00 0.00 0.00 42.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69437 Quantity/ConditionTotal

Location Details: Storage Room, adjoining room 232 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69436 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 232 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

58 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 24Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 40.00 0.00 1.00 0.00 41.00 square feet

- Presumed No Yes A 3

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Location: Floor 1: 69439 Quantity/ConditionTotal

Location Details: Vestibule, between rooms 231 and 232 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 139.00 0.00 0.00 0.00 139.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69438 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 231 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

59 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 25Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR Terrazzo 19 - - - - - - - - - - - -

Location: Floor 1: 69440-1 Quantity/ConditionTotal

Location Details: Stairwell, west of corridor 203 (Limited view above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

DUCTWORK Not Found 1 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 804.00 0.00 0.00 0.00 804.00 square feet

- Presumed No Yes A 6

WALL Ceramic 25 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes C 6

OTHER Horizontal Plaster Bulkhead 27 140.00 0.00 0.00 0.00 140.00 square feet

- Presumed No Yes C 6

WALL Plaster 18 1216.00 0.00 0.00 0.00 1216.00 square feet

- Presumed No Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69440 Quantity/Condition Total Location Details: Classroom, 208 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69439 Quantity/ConditionTotal

Location Details: Vestibule, between rooms 231 and 232 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

60 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 26Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Ceramic 25 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 788.00 0.00 0.00 0.00 788.00 square feet

- Presumed No Yes A 6

WALL Plaster 18 1204.00 0.00 0.00 0.00 1204.00 square feet

- Presumed No Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 17 0 0 0 17 each 75 Chrysotile Yes Yes A 6

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69441 Quantity/Condition Total Location Details: Classroom, 204 (No access above ceiling)

STRUCTURE Concrete 3 - - - - - - - - - - - -

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet

- Presumed No Yes A 6

WALL Brick 22 - - - - - - - - - - - -

WALL Metal 23 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 15 0 0 0 15 each 75 Chrysotile Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling space, suspect that ACMs may be present.

Location: Floor 1: 69440-1 Quantity/ConditionTotal

Location Details: Stairwell, west of corridor 203 (Limited view above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

61 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 27Golder Associates

Refer to Attachment for Definitions and Abbreviations

PIPING SYSTEMS Parging Cement On Fittings 7 10 0 0 0 10 each 75 Chrysotile Yes Yes A 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

PIPING SYSTEMS Bell & Spigot Joints 13 4 0 0 0 4 each - Presumed Yes Yes A 6

FLOOR 12" x 12" Vinyl Floor Tile 17 187.00 0.00 0.00 0.00 187.00 square feet

- Presumed No Yes A 6

CEILING New Ceiling Tile 16 - - - - - - - - - - - -

WALL Ceramic 25 - - - - - - - - - - - -

WALL Plaster 18 585.00 0.00 0.00 0.00 585.00 square feet

- Presumed No Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Other Suspect Piping 10 5.00 0.00 0.00 0.00 5.00 linear feet - Presumed Yes No D 6

CEILING Plaster 26 187.00 0.00 0.00 0.00 187.00 square feet

- Presumed No No D 6

STRUCTURE Wood 14 - - - - - - - - - - - -

Location: Floor 1: 69442 Quantity/ConditionTotal

Location Details: Office / Admin. Area, adjacent to room 208 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Horizontal Plaster Bulkhead 27 140.00 0.00 0.00 0.00 140.00 square feet

- Presumed No Yes C 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69441 Quantity/Condition Total Location Details: Classroom, 204 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

62 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 28Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Plaster 18 1192.00 0.00 0.00 0.00 1192.00 square feet

- Presumed No Yes A 6

FLOOR 12" x 12" Vinyl Floor Tile 17 770.00 0.00 0.00 0.00 770.00 square feet

- Presumed No Yes A 6

Location: Floor 1: 69443 Quantity/Condition Total Location Details: Classroom, 206 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Brick 22 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Plaster 18 430.00 0.00 0.00 0.00 430.00 square feet

- Presumed No Yes A 6

PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes C 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69442-1 Quantity/Condition Total Location Details: Corridor, Corridor 203 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Horizontal Plaster Bulkhead 27 60.00 0.00 0.00 0.00 60.00 square feet

- Presumed No Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69442 Quantity/ConditionTotal

Location Details: Office / Admin. Area, adjacent to room 208 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

63 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 29Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

WALL Brick 22 - - - - - - - - - - - -

WALL Metal 23 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 18 0 0 0 18 each 75 Chrysotile Yes Yes A 6

WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet

- Presumed No Yes A 6

FLOOR Terrazzo 19 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69443-1 Quantity/Condition Total Location Details: Stairwell, Stair A (Limited view above ceiling)

PIPING SYSTEMS Other Suspect Piping 10 5.00 0.00 0.00 0.00 5.00 linear feet - Presumed Yes Yes C 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

WALL Ceramic 25 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

OTHER Horizontal Plaster Bulkhead 27 140.00 0.00 0.00 0.00 140.00 square feet

- Presumed No Yes C 6

PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes C 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69443 Quantity/Condition Total Location Details: Classroom, 206 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

64 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 30Golder Associates

Refer to Attachment for Definitions and Abbreviations

OTHER Horizontal Plaster Bulkhead 27 140.00 0.00 0.00 0.00 140.00 square feet

- Presumed No Yes C 6

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 773.00 0.00 0.00 0.00 773.00 square feet

- Presumed No Yes A 6

WALL Plaster 18 1192.00 0.00 0.00 0.00 1192.00 square feet

- Presumed No Yes A 6

WALL Ceramic 25 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes C 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69444 Quantity/Condition Total Location Details: Classroom, 205 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling space, suspect that ACMs may be present.

Location: Floor 1: 69443-1 Quantity/Condition Total Location Details: Stairwell, Stair A (Limited view above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

65 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 31Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 198.00 0.00 0.00 0.00 198.00 square feet

- Presumed No Yes A 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69446 Quantity/Condition Total Location Details: Kitchen, 230 (No access above ceiling)

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR Vinyl Sheet Flooring 30 429.00 0.00 0.00 0.00 429.00 square feet

- Presumed Yes Yes A 6

WALL Wood 14 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69445 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 209 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

66 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 32Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 736.00 0.00 0.00 0.00 736.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

Location: Floor 1: 69448 Quantity/Condition Total Location Details: Classroom, 212 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 744.00 0.00 0.00 0.00 744.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69447 Quantity/Condition Total Location Details: Classroom, 211 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 5 0 0 0 5 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69446 Quantity/Condition Total Location Details: Kitchen, 230 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

67 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 33Golder Associates

Refer to Attachment for Definitions and Abbreviations

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Ceramic 25 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 239.00 0.00 0.00 0.00 239.00 square feet

- Presumed No Yes C 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling hatch; hatch stuck shut.

Location: Floor 1: 69449 Quantity/Condition Total Location Details: Washroom - Girls, 213A (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet

- Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69448 Quantity/Condition Total Location Details: Classroom, 212 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

68 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 34Golder Associates

Refer to Attachment for Definitions and Abbreviations

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 230.00 0.00 0.00 0.00 230.00 square feet

- Presumed No Yes C 6

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Ceramic 25 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69450 Quantity/Condition Total Location Details: Washroom - Boys, 216A (No access above ceiling)

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Wood 14 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69449-1 Quantity/Condition Total Location Details: Vestibule, 213 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

69 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 35Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING Drywall And Joint Compound 34 30.00 0.00 0.00 0.00 30.00 square feet

- Presumed No Yes C 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Wood 14 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

WALL Ceramic 25 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69451 Quantity/Condition Total Location Details: Washroom, Staff/215 (No access above ceiling)

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Wood 14 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 1: 69450-1 Quantity/Condition Total Location Details: Vestibule, 216 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

70 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 36Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Wood 14 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 1: 69452 Quantity/Condition Total Location Details: Caretakers Room, 214 (No access above ceiling)

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Metal 23 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

FLOOR Dirt, Sand Or Gravel 44 - - - - - - - - - - - -

WALL Concrete 3 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

PIPING SYSTEMS Other Suspect Piping 10 100.00 0.00 0.00 0.00 100.00 linear feet - Presumed Yes Yes B 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Bell & Spigot Joints 13 20 0 0 0 20 each - Presumed Yes Yes B 6

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

Comments: No access to tunnel below.

Location: Floor 1: 69451-1 Quantity/ConditionTotal

Location Details: Maintenance Room, pipe chase adjoining room 215 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

71 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 37Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Ceramic 25 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 39.00 0.00 0.00 0.00 39.00 square feet

- Presumed No Yes C 6

FLOOR Ceramic 25 - - - - - - - - - - - -

WALL Plaster 18 180.00 0.00 0.00 0.00 180.00 square feet

- Presumed No Yes A 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69239 Quantity/Condition Total Location Details: Washroom, Staff/324 (No access above ceiling)

WALL Brick 22 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 67.00 0.00 0.00 0.00 67.00 square feet

- Presumed No Yes C 6

WALL Plaster 18 250.00 0.00 0.00 0.00 250.00 square feet

- Presumed No Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 67.00 0.00 0.00 0.00 67.00 square feet

- Presumed No Yes A 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69238 Quantity/ConditionTotal

Location Details: Storage Room, Stockroom/325 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

72 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 38Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR 12" x 12" Vinyl Floor Tile 17 475.00 0.00 0.00 0.00 475.00 square feet

- Presumed No Yes A 6

WALL Plaster 18 610.00 0.00 0.00 0.00 610.00 square feet

- Presumed No Yes A 6

WALL Marble 31 - - - - - - - - - - - -

Location: Floor 2: 69241 Quantity/Condition Total Location Details: Staff Room, Staff/323 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 85.00 0.00 0.00 0.00 85.00 square feet

- Presumed No Yes A 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 85.00 0.00 0.00 0.00 85.00 square feet

- Presumed No Yes C 6

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

WALL Plaster 18 250.00 0.00 0.00 0.00 250.00 square feet

- Presumed No Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69240 Quantity/Condition Total Location Details: Kitchen, 323A (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69239 Quantity/Condition Total Location Details: Washroom, Staff/324 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

73 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 39Golder Associates

Refer to Attachment for Definitions and Abbreviations

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 450.00 0.00 0.00 0.00 450.00 square feet

- Presumed No Yes A 6

WALL Plaster 18 300.00 0.00 0.00 0.00 300.00 square feet

- Presumed No Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69241-1 Quantity/ConditionTotal

Location Details: Corridor, outside room 324 (No access above ceiling)

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Vertical Plaster Bulkhead 36 20.00 0.00 0.00 0.00 20.00 square feet

- Presumed No Yes A 6

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69241 Quantity/Condition Total Location Details: Staff Room, Staff/323 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

74 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 40Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Marble 31 - - - - - - - - - - - -

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Plaster 18 400.00 0.00 0.00 0.00 400.00 square feet

- Presumed No Yes A 6

WALL Metal 23 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69242-1 Quantity/ConditionTotal

Location Details: Stairwell, west of corridor 301 (No access above ceiling)

WALL Marble 31 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Brick 22 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 115.00 0.00 0.00 0.00 115.00 square feet

- Presumed No Yes A 6

FLOOR Vinyl Sheet Flooring 30 689.00 0.00 0.00 0.00 689.00 square feet

- Presumed Yes Yes A 6

WALL Wood 14 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

OTHER Vinyl Countertop 32 10.00 0.00 0.00 0.00 10.00 square feet

- Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69242 Quantity/Condition Total Location Details: Classroom, 305 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

75 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 41Golder Associates

Refer to Attachment for Definitions and Abbreviations

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR Vinyl Sheet Flooring 30 50.00 0.00 0.00 0.00 50.00 square feet

- Presumed Yes Yes A 6

FLOOR 12" x 12" Vinyl Floor Tile 17 738.00 0.00 0.00 0.00 738.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Drywall And Joint Compound 33 35.00 0.00 0.00 0.00 35.00 square feet

- Presumed No Yes A 6

WALL Marble 31 - - - - - - - - - - - -

Location: Floor 2: 69243 Quantity/Condition Total Location Details: Classroom, 326 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes C 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69242-1 Quantity/ConditionTotal

Location Details: Stairwell, west of corridor 301 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

76 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 42Golder Associates

Refer to Attachment for Definitions and Abbreviations

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Vinyl Countertop 32 20.00 0.00 0.00 0.00 20.00 square feet

- Presumed Yes Yes A 6

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

WALL Brick 22 - - - - - - - - - - - -

WALL Drywall And Joint Compound 33 60.00 0.00 0.00 0.00 60.00 square feet

- Presumed No Yes A 6

FLOOR 12" x 12" Vinyl Floor Tile 17 153.00 0.00 0.00 0.00 153.00 square feet

- Presumed No Yes A 6

WALL Plaster 18 105.00 0.00 0.00 0.00 105.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69244 Quantity/ConditionTotal

Location Details: Teachers Workroom, Tutorial/304 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Vinyl Countertop 32 15.00 0.00 0.00 0.00 15.00 square feet

- Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to fan enclosure EF-05.

Location: Floor 2: 69243 Quantity/Condition Total Location Details: Classroom, 326 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

77 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 43Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Drywall And Joint Compound 33 136.00 0.00 0.00 0.00 136.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

FLOOR Vinyl Sheet Flooring 30 22.00 0.00 0.00 0.00 22.00 square feet

- Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69245 Quantity/Condition Total Location Details: Washroom, 304A (No access above ceiling)

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Plaster 18 600.00 0.00 0.00 0.00 600.00 square feet

- Presumed No Yes A 6

WALL Ceramic 25 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69244-1 Quantity/Condition Total Location Details: Corridor, Corridor 301 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

78 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 44Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Marble 31 - - - - - - - - - - - -

WALL Drywall And Joint Compound 33 35.00 0.00 0.00 0.00 35.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 672.00 0.00 0.00 0.00 672.00 square feet

- Presumed No Yes A 6

FLOOR Vinyl Sheet Flooring 30 50.00 0.00 0.00 0.00 50.00 square feet

- Presumed Yes Yes A 6

WALL Wood 14 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69247 Quantity/Condition Total Location Details: Classroom, 327 (No access above ceiling)

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 10.00 0.00 0.00 0.00 10.00 square feet

- Presumed No Yes B 6

WALL Brick 22 - - - - - - - - - - - -

WALL Drywall And Joint Compound 33 60.00 0.00 0.00 0.00 60.00 square feet

- Presumed No Yes B 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Bell & Spigot Joints 13 5 0 0 0 5 each - Presumed Yes Yes B 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69246 Quantity/Condition Total Location Details: Caretakers Room, 303 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

79 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 45Golder Associates

Refer to Attachment for Definitions and Abbreviations

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR Vinyl Sheet Flooring 30 655.00 0.00 0.00 0.00 655.00 square feet

- Presumed Yes Yes A 6

FLOOR 12" x 12" Vinyl Floor Tile 17 115.00 0.00 0.00 0.00 115.00 square feet

- Presumed No Yes A 6

WALL Marble 31 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Drywall And Joint Compound 33 35.00 0.00 0.00 0.00 35.00 square feet

- Presumed No Yes A 6

Location: Floor 2: 69248 Quantity/Condition Total Location Details: Classroom, 302 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Vinyl Countertop 32 15.00 0.00 0.00 0.00 15.00 square feet

- Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to fan enclosure EF-04.

Location: Floor 2: 69247 Quantity/Condition Total Location Details: Classroom, 327 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

80 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 46Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Wood 14 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

Location: Floor 2: 69249 Quantity/Condition Total Location Details: Caretakers Room, 308 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles

24 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Metal 23 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Plaster 18 400.00 0.00 0.00 0.00 400.00 square feet

- Presumed No Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69248-1 Quantity/Condition Total Location Details: Stairwell, Stair A (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Vinyl Countertop 32 15.00 0.00 0.00 0.00 15.00 square feet

- Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to fan enclosure EF-03.

Location: Floor 2: 69248 Quantity/Condition Total Location Details: Classroom, 302 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

81 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 47Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Wood 14 - - - - - - - - - - - -

WALL Ceramic 25 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69251 Quantity/Condition Total Location Details: Washroom - Boys, 310 (No access above ceiling)

WALL Ceramic 25 - - - - - - - - - - - -

CEILING Wood 14 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69250 Quantity/Condition Total Location Details: Washroom - Girls, 307 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69249 Quantity/Condition Total Location Details: Caretakers Room, 308 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

82 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 48Golder Associates

Refer to Attachment for Definitions and Abbreviations

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet

- Presumed Yes Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 744.00 0.00 0.00 0.00 744.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69252 Quantity/Condition Total Location Details: Classroom, 311 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69251 Quantity/Condition Total Location Details: Washroom - Boys, 310 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

83 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 49Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet

- Presumed No Yes A 6

WALL Brick 22 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69253-1 Quantity/ConditionTotal

Location Details: Corridor, E-W outside Stair C (No access above ceiling)

CEILING Plaster 26 27.00 0.00 0.00 0.00 27.00 square feet

- Presumed No Yes A 6

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Plaster 18 18.00 0.00 0.00 0.00 18.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 10 0 0 0 10 each - Presumed Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69253 Quantity/ConditionTotal

Location Details: Corridor, N-S outside room 312 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

84 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 50Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR 9" x 9" Vinyl Floor Tile 21 20.00 0.00 1.00 0.00 21.00 square feet

- Presumed No Yes A 3

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69255 Quantity/Condition Total Location Details: Washroom, 314A (No access above ceiling)

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 736.00 0.00 0.00 0.00 736.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet

- Presumed Yes Yes A 6

WALL Wood 14 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69254 Quantity/Condition Total Location Details: Classroom, 312 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69253-1 Quantity/ConditionTotal

Location Details: Corridor, E-W outside Stair C (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

85 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 51Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

WALL Plaster 18 360.00 0.00 0.00 0.00 360.00 square feet

- Presumed No Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 182.00 0.00 0.00 0.00 182.00 square feet

- Presumed No Yes A 6

FLOOR 12" x 12" Vinyl Floor Tile 17 4.00 0.00 0.00 0.00 4.00 square feet

- Presumed No Yes A 6

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69256 Quantity/ConditionTotal

Location Details: Teachers Workroom, 314 (No access above ceiling)

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Plaster 18 125.00 0.00 0.00 0.00 125.00 square feet

- Presumed No Yes A 6

CEILING Drywall And Joint Compound 34 21.00 0.00 0.00 0.00 21.00 square feet

- Presumed No Yes C 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69255 Quantity/Condition Total Location Details: Washroom, 314A (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

86 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 52Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR 12" x 12" Vinyl Floor Tile 17 45.00 0.00 0.00 0.00 45.00 square feet

- Presumed No Yes A 6

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69258 Quantity/Condition Total Location Details: Photocopy Room, 314B (No access above ceiling)

CEILING Drywall And Joint Compound 34 102.00 0.00 0.00 0.00 102.00 square feet

- Presumed No Yes C 6

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 102.00 0.00 0.00 0.00 102.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

WALL Plaster 18 120.00 0.00 0.00 0.00 120.00 square feet

- Presumed No Yes A 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Horizontal Drywall Bulkhead 38 20.00 0.00 0.00 0.00 20.00 square feet

- Presumed No Yes C 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69257 Quantity/Condition Total Location Details: Hub Room, 315 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access beneath sink.

Location: Floor 2: 69256 Quantity/ConditionTotal

Location Details: Teachers Workroom, 314 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

87 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 53Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 213.00 0.00 0.00 0.00 213.00 square feet

- Presumed No Yes C 6

WALL Wood 14 - - - - - - - - - - - -

WALL Brick 22 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 213.00 0.00 0.00 0.00 213.00 square feet

- Presumed No Yes A 6

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69259 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 317 (No access above ceiling)

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet

- Presumed No Yes A 6

FLOOR 9" x 9" Vinyl Floor Tile 21 64.00 0.00 0.00 0.00 64.00 square feet

- Presumed No Yes A 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69258 Quantity/Condition Total Location Details: Photocopy Room, 314B (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

88 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 54Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR 12" x 12" Vinyl Floor Tile 17 177.00 0.00 0.00 0.00 177.00 square feet

- Presumed No Yes A 6

WALL Drywall And Joint Compound 33 257.00 0.00 0.00 0.00 257.00 square feet

- Presumed No Yes A 6

Location: Floor 2: 69261 Quantity/ConditionTotal

Location Details: Office / Admin. Area, Staff/318B (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 23.00 0.00 0.00 0.00 23.00 square feet

- Presumed No Yes C 6

WALL Plaster 18 95.00 0.00 0.00 0.00 95.00 square feet

- Presumed No Yes B 6

WALL Concrete Block 4 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 23.00 0.00 0.00 0.00 23.00 square feet

- Presumed No Yes B 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69260 Quantity/Condition Total Location Details: Caretakers Room, 316 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes C 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69259 Quantity/ConditionTotal

Location Details: Office / Admin. Area, 317 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

89 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 55Golder Associates

Refer to Attachment for Definitions and Abbreviations

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

CEILING 1x1 random medium and large holes Glue On Ceiling Tiles

39 - - - - - - <LOD No Asbestos Detected

- - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 167.00 0.00 0.00 0.00 167.00 square feet

- Presumed No Yes A 6

WALL Drywall And Joint Compound 33 266.00 0.00 0.00 0.00 266.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69453 Quantity/ConditionTotal

Location Details: Teachers Workroom, 318A (No access above ceiling)

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING 1x1 random medium and large holes Glue On Ceiling Tiles

39 - - - - - - <LOD No Asbestos Detected

- - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Window Sealers 12 4 0 0 0 4 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69261 Quantity/ConditionTotal

Location Details: Office / Admin. Area, Staff/318B (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

90 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 56Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Plaster 18 8.00 0.00 0.00 0.00 8.00 square feet

- Presumed No Yes C 6

FLOOR Terrazzo 19 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69454-1 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)

CEILING 1x1 random medium and large holes Glue On Ceiling Tiles

39 - - - - - - <LOD No Asbestos Detected

- - - -

WALL Concrete Block 4 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 1320.00 0.00 0.00 0.00 1320.00 square feet

- Presumed No Yes A 6

WALL Drywall And Joint Compound 33 215.00 0.00 0.00 0.00 215.00 square feet

- Presumed No Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 15 0 0 0 15 each - Presumed Yes Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69454 Quantity/Condition Total Location Details: Library, 318 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Vertical Drywall Bulkhead 40 35.00 0.00 0.00 0.00 35.00 square feet

- Presumed No Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69453 Quantity/ConditionTotal

Location Details: Teachers Workroom, 318A (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

91 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 57Golder Associates

Refer to Attachment for Definitions and Abbreviations

PIPING SYSTEMS Parging Cement On Fittings 7 3 2 0 0 5 each 75 Chrysotile Yes No D 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

FLOOR 12" x 12" Vinyl Floor Tile 17 720.00 0.00 0.00 0.00 720.00 square feet

- Presumed No Yes A 6

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

STRUCTURE Wood 14 - - - - - - - - - - - -

Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69455 Quantity/ConditionTotal

Location Details: Corridor, E-W outside room 318 (Limited view above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

OTHER Window Sealers 12 8 0 0 0 8 each - Presumed Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69454-1 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

92 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 58Golder Associates

Refer to Attachment for Definitions and Abbreviations

CEILING Not Found 1 - - - - - - - - - - - -

STRUCTURE Wood 14 - - - - - - - - - - - -

DUCTWORK Parging Cement On Seam, Joints And Pins 48 25.00 0.00 0.00 0.00 25.00 square feet

50 Chrysotile Yes Yes C 6

WALL Concrete 3 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

WALL Perforated Transite Asbestos Cement 47 180.00 0.00 0.00 0.00 180.00 square feet

- Presumed No Yes B 6

MECHANICAL EQUIPMENT

Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 25 0 0 0 25 each 75 Chrysotile Yes Yes B 6

FLOOR Concrete 3 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69457 Quantity/Condition Total Location Details: Mechanical Room, 318D (Open)

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Drywall And Joint Compound 34 80.00 0.00 0.00 0.00 80.00 square feet

- Presumed No Yes C 6

FLOOR 9" x 9" Vinyl Floor Tile 21 79.00 0.00 1.00 0.00 80.00 square feet

- Presumed No Yes A 3

WALL Concrete Block 4 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -

PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69456 Quantity/Condition Total Location Details: Storage Room, 318C (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

93 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 59Golder Associates

Refer to Attachment for Definitions and Abbreviations

FLOOR 9" x 9" Vinyl Floor Tile 21 700.00 0.00 0.00 0.00 700.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

Location: Floor 2: 69459 Quantity/Condition Total Location Details: Classroom, 319 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

WALL Wood 14 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 1597.00 0.00 0.00 0.00 1597.00 square feet

- Presumed No Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Vertical Drywall Bulkhead 40 50.00 0.00 0.00 0.00 50.00 square feet

- Presumed No Yes A 6

OTHER Window Sealers 12 18 0 0 0 18 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

CEILING 1x1 random medium and large holes Glue On Ceiling Tiles

39 - - - - - - <LOD No Asbestos Detected

- - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69458 Quantity/Condition Total Location Details: Library, 318 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

OTHER Woven Flexible Duct Connector 37 0.00 0.00 0.00 0.00 0.00 square feet

- Presumed No No N/A

OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes C 6

Location: Floor 2: 69457 Quantity/Condition Total Location Details: Mechanical Room, 318D (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

94 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 60Golder Associates

Refer to Attachment for Definitions and Abbreviations

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Wood 14 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 12" x 12" Vinyl Floor Tile 17 56.00 0.00 0.00 0.00 56.00 square feet

- Presumed No Yes A 6

FLOOR 9" x 9" Vinyl Floor Tile 21 84.00 0.00 0.00 0.00 84.00 square feet

- Presumed No Yes A 6

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69460 Quantity/Condition Total Location Details: Storage Room, 320 (No access above ceiling)

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet

- Presumed Yes Yes A 6

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69459 Quantity/Condition Total Location Details: Classroom, 319 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

95 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 61Golder Associates

Refer to Attachment for Definitions and Abbreviations

DUCTWORK Not Found 1 - - - - - - - - - - - -

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet

- Presumed Yes Yes A 6

OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 767.00 0.00 0.00 0.00 767.00 square feet

- Presumed No Yes A 6

WALL Wood 14 - - - - - - - - - - - -

WALL Wood 14 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Floor 2: 69462 Quantity/Condition Total Location Details: Classroom, A321 (No access above ceiling)

STRUCTURE Wood 14 - - - - - - - - - - - -

DUCTWORK Uninsulated 2 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

FLOOR Concrete 3 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Uninsulated 2 - - - - - - - - - - - -

OTHER Woven Flexible Duct Connector 37 0.00 0.00 0.00 0.00 0.00 square feet

- Presumed No No N/A

PIPING SYSTEMS Bell & Spigot Joints 13 6 0 0 0 6 each - Presumed Yes Yes B 6

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Location: Floor 2: 69461 Quantity/Condition Total Location Details: Mechanical Room, 322 (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

96 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 62Golder Associates

Refer to Attachment for Definitions and Abbreviations

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Vertical Plaster Bulkhead 36 15.00 0.00 0.00 0.00 15.00 square feet

- Presumed No Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

WALL Plaster 18 220.00 0.00 0.00 0.00 220.00 square feet

- Presumed No Yes A 6

FLOOR 9" x 9" Vinyl Floor Tile 21 43.00 0.00 0.00 0.00 43.00 square feet

- Presumed No Yes A 6

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69463 Quantity/Condition Total Location Details: Empty Room, 313 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

STRUCTURE Not Found 1 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -

FLOOR Terrazzo 19 - - - - - - - - - - - -

WALL Concrete Block 4 - - - - - - - - - - - -

OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69462-1 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

97 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 63Golder Associates

Refer to Attachment for Definitions and Abbreviations

WALL Concrete 3 - - - - - - - - - - - -

CEILING Transite Asbestos Cement 43 360.00 0.00 0.00 0.00 360.00 square feet

- Presumed No Yes C 6

WALL Transite Asbestos Cement 29 700.00 0.00 0.00 0.00 700.00 square feet

- Presumed No Yes C 6

FLOOR Other Non-Suspect 49 - - - - - - - - - - - -

WALL Brick 22 - - - - - - - - - - - -

STRUCTURE Concrete 3 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Bell & Spigot Joints 13 3 0 0 0 3 each - Presumed Yes Yes A 6

FLOOR Concrete 3 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Exterior: 68443-1 Quantity/Condition Total Location Details: Exterior (Open)

STRUCTURE Not Found 1 - - - - - - - - - - - -

CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles

35 - - - - - - <LOD No Asbestos Detected

- - - -

FLOOR 9" x 9" Vinyl Floor Tile 21 83.00 0.00 0.00 0.00 83.00 square feet

- Presumed No Yes A 6

WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet

- Presumed No Yes A 6

DUCTWORK Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -

Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.

Location: Floor 2: 69464 Quantity/ConditionTotal

Location Details: Computer Room, adjoining room 314 (No access above ceiling)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

98 of 99

Date: 11/21/2008

Job Number : 06-1113-212Facility : 3088 - Dublin PS

Client : Toronto District School Board

All Components

Appendix IV - Room-by-Room Details: Summary Report By Location

Page: 64Golder Associates

Refer to Attachment for Definitions and Abbreviations

STRUCTURE Not Found 1 - - - - - - - - - - - -

FLOOR Built Up Membrane Roof 52 22000.00 0.00 0.00 0.00 22000.00 square feet

- Presumed No Yes B 6

WALL Not Found 1 - - - - - - - - - - - -

CEILING Not Found 1 - - - - - - - - - - - -

OTHER Brick/Block/Concrete 5 - - - - - - - - - - - -

DUCTWORK Not Found 1 - - - - - - - - - - - -

PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Location: Roof: 68443 Quantity/Condition Total Location Details: Roof (Open)

MECHANICAL EQUIPMENT

Not Found 1 - - - - - - - - - - - -

OTHER Not Found 1 - - - - - - - - - - - -

Location: Exterior: 68443-1 Quantity/Condition Total Location Details: Exterior (Open)

System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %

Asbestos Type

Friable Visible Accessibility Action Code

Building: 1 (Dublin PS)

99 of 99