ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND CONTRACT DOCUMENTS 2018 MACON-BIBB COUNTY STORMWATER CULVERT REPAIR/REPLACEMENT (GROUP 3) FOR MACON WATER AUTHORITY MACON, GEORGIA AGENT OF MACON-BIBB, GA AUGUST 2019 1. Revised plan sheets and supplemental details have been attached to provide additional clarification on the design of the proposed headwalls. Contractor is still responsible for field confirming designs will match field conditions. Contractor shall notify Engineer / MWA prior to ordering headwalls if design updates may be required. 2. Information on the size, type, dimensions, estimated backfill quantity has been provided for all headwalls shown on the plans. Additionally, clarification on headwalls expected to be pre-cast or poured in place has been included. No change to the Bid Form or Measurement and Payment technical specification has been made. Backfill soil, bedding materials, brick, grouting, etc. all remain incidental and should be included in the unit price provided for each headwall. Bid prices provided for headwalls shall consider all new design updates included in this addendum. 3. Bidders shall note that headwalls 2A, 4A, 4B, 10D and 11B now include a concrete apron as shown on the supplementary details. Costs for the concrete aprons shall be included in the unit price provided for the headwall on those applicable Bid Forms. --- END OF ADDENDUM NO. 1 ---

Upload: others

Post on 03-Nov-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

ADDENDUM NO. 1

DATE: August 2, 2019

SPECIFICATIONS AND CONTRACT DOCUMENTS 2018 MACON-BIBB COUNTY STORMWATER CULVERT

REPAIR/REPLACEMENT (GROUP 3) FOR

MACON WATER AUTHORITY MACON, GEORGIA

AGENT OF MACON-BIBB, GA

AUGUST 2019

1. Revised plan sheets and supplemental details have been attached to provideadditional clarification on the design of the proposed headwalls. Contractoris still responsible for field confirming designs will match field conditions.Contractor shall notify Engineer / MWA prior to ordering headwalls if designupdates may be required.

2. Information on the size, type, dimensions, estimated backfill quantity hasbeen provided for all headwalls shown on the plans. Additionally,clarification on headwalls expected to be pre-cast or poured in place hasbeen included. No change to the Bid Form or Measurement and Paymenttechnical specification has been made. Backfill soil, bedding materials,brick, grouting, etc. all remain incidental and should be included in the unitprice provided for each headwall. Bid prices provided for headwalls shallconsider all new design updates included in this addendum.

3. Bidders shall note that headwalls 2A, 4A, 4B, 10D and 11B now include aconcrete apron as shown on the supplementary details. Costs for theconcrete aprons shall be included in the unit price provided for the headwallon those applicable Bid Forms.

--- END OF ADDENDUM NO. 1 ---

Page 2: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

Structural Engineering Consultants

August 2, 2019 Eric Jackson Hodges, Harbin, Newberry, and Tribble, Inc. 3920 Arkwright Road, Suite 101 Macon, GA 31210 Re: Bibb County Stormwater Improvement Headwalls Pi-Tech, Inc. has reviewed the proposed headwalls to be used at several new stormwater drainage locations. Wall types, pipe sizes, and topographical details were provided on 7/26/2019. There are three types of proposed headwalls: straight walls, 45-degree wing walls, and L shaped walls. All of these headwalls are constructed from plain, unreinforced concrete. All of the designs are based on GDOT Standard 1001-B and modified where necessary to account for the situations present at these locations. Retained soil height, slope, and proximity to roadway were all considered as a part of this analysis. In order to analyze the system, we made the following engineering assumptions.

• All concrete to be used will be Georgia DOT Class “B” concrete with a yield stress of 2200 psi and will be of normal weight.

• The soil in these locations will have a maximum weight of 120 pcf. • A minimum bearing pressure of 2000 psf with a soil subgrade modulus of 100 pci.

The proposed headwalls were analyzed using IES QuickRWall 5.0 and IES Visual Analysis 18.0. Plain concrete checks were performed in accordance with ACI 318-11. Based on this, a marked-up version of the 1001-B detail was created for each individual headwall. These details are attached to this letter. If you have any questions, or require further information, please feel free to contact us. Sincerely,

D. Scott Pipkins, Ph.D., P.E. Paul Johnson, E.I.T. Principal Engineer Project Engineer

Pi-Tech, Inc. P.O. Box 6631 Macon, GA 31208-6631 Phone: (478)743-5600 Fax: (478)743-5640 web: www.pi-techinc.com

Page 3: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
1A L Wall Headwall
pjohnson
Line
pjohnson
Text Box
18"
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
Provide 22" wide x 1'-9" deep key underneath wall stem.
pjohnson
Line
pjohnson
Rectangle
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
3'-6"
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
22"
pjohnson
Text Box
22"
pjohnson
Text Box
D+42"
pjohnson
Line
pjohnson
Text Box
3'-6"
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
22"
pjohnson
Text Box
22"
pjohnson
Line
Page 4: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
1B 45 degree Wing Wall Headwall
pjohnson
Rectangle
Page 5: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
2A 45 degree Wing Wall Headwall
pjohnson
Text Box
Add Line to Schedule: D=72" H=7'-0" G=8'-4" M=9'-10" L=3'-6" F=2'-6" Keep same tie rods.
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
21" stem
pjohnson
Line
pjohnson
Text Box
21" stem
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
Fill in invert this headwall, infill to match footing thickness
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
Provide 21" wideX15" deep concrete key under stem
pjohnson
Line
Page 6: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
2B 45 degree Wing Wall Headwall
pjohnson
Text Box
Add Line to Schedule: D=72" H=7'-0" G=8'-4" M=9'-10" L=3'-6" F=2'-6" Keep same tie rods.
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
12" stem
pjohnson
Line
pjohnson
Text Box
12" stem
pjohnson
Line
Page 7: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
3A 45 degree Wing Wall Headwall
pjohnson
Text Box
Add Line to Schedule: D=60" Tallx78" Wide ellipse H=6'-0" G=8'-10" M=7'-6" L=3'-6" F=2'-0" Keep same tie rods.
Page 8: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
3B 45 degree Wing Wall Headwall
pjohnson
Text Box
Add Line to Schedule: D=60" Tallx78" Wide ellipse H=6'-0" G=12'-0" (accomodates 15" existing pipe) M=7'-6" L=3'-6" F=2'-0" Keep same tie rods.
Page 9: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
4A 45 degree Wing Wall Headwall
pjohnson
Line
pjohnson
Text Box
Fill in invert, thickness to match footing thickness
pjohnson
Line
pjohnson
Text Box
Add Line to Schedule: D=66" tall x90" wide ellipse H=6'-6" G=9'-10" M=8'-6" L=3'-6" F=2'-0" Keep same tie rods.
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
18" stem
pjohnson
Line
pjohnson
Text Box
18" stem
pjohnson
Line
pjohnson
Text Box
2'-2"
pjohnson
Line
Page 10: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
4B 45 degree Wing Wall Headwall
pjohnson
Line
pjohnson
Text Box
Fill in invert, thickness to match footing thickness
pjohnson
Line
pjohnson
Text Box
Add Line to Schedule: D=66" tall x90" wide ellipse H=6'-6" G=9'-10" M=8'-6" L=3'-6" F=2'-0" Keep same tie rods.
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
18" stem
pjohnson
Line
pjohnson
Text Box
18" stem
pjohnson
Line
pjohnson
Text Box
2'-2"
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
Provide 18" wideX15" deep concrete key under stem
Page 11: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
5A 45 degree Wing Wall Headwall
pjohnson
Rectangle
Page 12: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
5B 45 degree Wing Wall Headwall
pjohnson
Rectangle
Page 13: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
10A L Wall Headwall
pjohnson
Line
pjohnson
Text Box
12"
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
Provide 10" wide x 15" deep key underneath wall stem.
pjohnson
Line
pjohnson
Rectangle
pjohnson
Line
Page 14: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
10B 45 degree Wing Wall Headwall
pjohnson
Rectangle
Page 15: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
10"
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Rectangle
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
Replace "E" dimension with 4'-0"
pjohnson
Line
pjohnson
Text Box
10C Straight Wall Headwall
pjohnson
Line
Page 16: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
10D 45 degree Wing Wall Headwall
pjohnson
Rectangle
pjohnson
Line
pjohnson
Text Box
Fill in invert, thickness to match footing thickness
pjohnson
Line
Page 17: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
21"
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
11A Straight Wall Headwall
pjohnson
Text Box
Add new line to bottom of table: D=66" G=22'-0" H=6'-6" B=2'-6" E=6'-0" F=2'-6"
Page 18: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
11B 45 degree Wing Wall Headwall
pjohnson
Line
pjohnson
Text Box
Fill in invert, thickness to match footing thickness
pjohnson
Line
pjohnson
Text Box
Add Line to Schedule: D=66" H=6'-6" G=7'-10" M=7'-6" L=3'-6" F=2'-0" Keep same tie rods.
pjohnson
Line
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
14" stem
pjohnson
Line
pjohnson
Text Box
14" stem
pjohnson
Line
pjohnson
Text Box
1'-10"
pjohnson
Line
Page 19: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
12A 45 degree Wing Wall Headwall
pjohnson
Rectangle
pjohnson
Line
pjohnson
Text Box
12" Stem
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
1'-8"
pjohnson
Line
pjohnson
Line
pjohnson
Text Box
12" Stem
pjohnson
Line
Page 20: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Rectangle
pjohnson
Text Box
12B 45 degree Wing Wall Headwall
pjohnson
Rectangle
Page 21: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

0+00 0+25 0+50

EX

IS

TIN

G 42"C

MP

IN

V:424.21

EX

IS

TIN

G 42"C

MP

IN

V:425.84

0+75

420

430

440

EXISTING

GROUND

ELEVATION

1+00

EXISTING

ROADWAY

APPROX. LOCATION

OF EXISTING 6"DIA.

DIP WATER LINE

APPROX. LOCATION OF

EXISTING GAS LINE

EXISTING UNDERGROUND

UTILITIES (TYP.)

420

430

440

4

2

3

106

431.94

CO

SSMH

RIM: 432.66

INV A:423.93

INV B:423.22

4

2

5

4

3

0

4

3

5

4

3

4

4

3

5

4

3

0

4

2

9

4

2

8

4

2

8

4

2

9

4

3

1

4

3

2

4

3

3

4

3

4

4

3

6

4

2

4

4

2

6

4

2

74

2

8

4

2

9

4

3

1

4

3

2

4

3

3

4

3

4

8"PV

C

8"P

VC

SSMH

RIM: 430.62

INV A:-9568.38

INV B:-9568.38

A

B

A

B

NOW OR FORMERLY

CHARLES T. & KATHY BRANCH

PARCEL J007-0101

DB 1764, PG 567

PB 54, PG 43

NOW OR FORMERLY

WALTER & JENNIFER MCNATT

PARCEL K007-0051

DB 8476, PG 173

PB 54, PG 43E

XIS

TIN

G 2

0'

DR

AIN

AG

E

EA

SE

M

EN

T

NOW OR FORMERLY

PAMELA W. LAWSON

PARCEL K007-0067

DB 8162, PG 171

PB 54, PG 43

.5IN RB

E

X

IS

T

IN

G

2

0

'

D

R

A

I

N

A

G

E

E

A

S

E

M

E

N

T

EXISTING

INV. 424.21

EXISTING

INV. 425.84

N

X

X

STRATFORD HILLS DRIVE (55' R/W)

XX

PROFILE VIEW

SCALE: H:1"=20', V:1"=5'

3920 ARKWRIGHT RD.(478) 743-7175

DATE

SHEET OF

SCALE

PROJ. NO.

CULVERTS REPAIR / REPLACEMENT (GROUP 3)

MACON WATER AUTHORITY

FOR

JUNE 2019

5020-023-01

SUITE 101(478) 743-1703(FAX) MACON, GEORGIA 31210

BIBB COUNTY, GEORGIA

13

2018 MACON - BIBB COUNTYWIDE STORMWATER

DWG.

No. 30797PROFESSIONAL

D

A

N

I

E

L

E

.

C

H

E

E

K

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

EDIT

No. 37584PROFESSIONAL

E

R

I

C

P

I

E

RCE

J

A

C

K

S

O

N

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

MWA-2018 SW

4305' CONTOUR LINE

SANITARY SEWER MANHOLE

WATER METER

STORM SEWER LINE

SANITARY SEWER LINE

UNDERGROUND POWER

ASPHALT

LEGEND

UP

SAN

UNDERGROUND TELEPHONE UT

WATER LINE W

CLEAN OUT

TRANSFORMER

GAS LINE

4281' CONTOUR LINE

1

GRAPHIC SCALE IN FEET

0 40201020

DISCLAIMER:

1. THE DESIGN / ENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED ON THE TOPOGRAPHY,

EXISTING CONDITIONS, OR DESIGNS BY OTHERS AS REFERENCED. SHOULD ANY OF THE EXISTING CONDITIONS

OR TOPOGRAPHY BE FOUND TO BE DIFFERENT OR CHANGED, THE DESIGN ENGINEER THAT PREPARED THIS

PLAN SHOULD BE CONTACTED PRIOR TO CONSTRUCTING / IMPLEMENTING THIS DESIGN, AND TO DETERMINE IF

DESIGN REVISIONS ARE REQUIRED.

2. THE ENGINEER THAT PREPARED THIS DRAWING HAS ASSUMED THAT THE CONSTRUCTION WILL BE PERFORMED

IN ACCORDANCE WITH THE ENGINEERING INTENT AND COMPLETE CONSTRUCTION SPECIFICATIONS WILL BE

PREPARED TO ACCOMPANY THE DRAWINGS. THE ENGINEER EXPECTS THAT HE WILL BE INVOLVED WITH,

PROVIDED AN OPPORTUNITY TO REVIEW, AND INSPECT PRODUCTS AND CONSTRUCTION OF THE

IMPROVEMENTS SHOWN ON THIS PLAN SHEET IN ORDER TO CONFIRM THAT THE CONSTRUCTION OF THE

IMPROVEMENTS ARE INSTALLED IN ACCORDANCE WITH DESIGN CONCEPTS. SHOULD THE DESIGN ENGINEER

NOT BE INVOLVED WITH CONSTRUCTION, HE WILL NOT BE LIABLE FOR CHANGES IN CONDITIONS OR FIELD

CONDITIONS THAT MAY AFFECT THE DESIGN.

1" = 20'

PROJECT 1 - 5417 STRATFORD HILLS DRIVE

8-2-19

PLAN VIEW

SCALE: 1"=20'

CONTRACTOR TO REMOVE

EXISTING 42" DIA. CMP

DOUBLE ROW OF SENSITIVE

SILT FENCE (TYPE-C)

(TYP.)

Sd1-S

±55 LF OF 42" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 2.9%.

CLASS 'A' ASPHALT

PAVEMENT REPLACEMENT

PROPOSED HEADWALL 1-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 54" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HW-1A. SHALL BE POUR-IN-PLACE

L-SHAPED REINFORCED CONCRETE HEADWALL

WITH 54" DIA. OPENING PER GDOT 1001-B

STANDARDS

55 SY OF 9" DIA. RIP-RAP

OUTLET PROTECTION

OP

G

NOTES:

1. EXISTING CONDITION INFORMATION TAKEN FROM THE "TOPOGRAPHIC SURVEY" PREPARED BY WELLSTON

ASSOCIATES LAND SURVEYORS, LLC, DATE OF SURVEY: MARCH 7, 2016.

2. THE UNDERGROUND UTILITIES SHOWN ON THIS DRAWING WERE COMPILED FROM FIELD OBSERVATIONS

WITHOUT BENEFIT OF EXCAVATION. WELLSTON ASSOCIATES LAND SURVEYORS, LLC DOES NOT

GUARANTEE THAT ALL UTILITIES ARE SHOWN. VERIFICATION OF UTILITIES SHOULD BE MADE BY THE

INDIVIDUAL UTILITY COMPANY PRIOR TO ANY CONSTRUCTION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO CONSTRUCTION. DEPTH OF

ALL EXISTING UTILITIES SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. MATERIALS

FOR ANY REQUIRED WATER OR SEWER SYSTEM RELOCATION WILL BE PROVIDED BY THE MACON WATER

AUTHORITY, BUT INSTALLATION, INCLUDING BYPASS, WILL BE INCIDENTAL TO THE CONSTRUCTION OF THE

INDIVIDUAL PROJECT. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED UTILITY RELOCATIONS.

4. CONTRACTOR WILL BE RESPONSIBLE FOR STORM WATER MANAGEMENT AND TRAFFIC CONTROL IN THE

PROJECT AREA DURING CONSTRUCTION. ALL STORMWATER SHALL BE IN ACCORDANCE WITH THE "LOCAL

STORMWATER DESIGN MANUAL FOR MACON - BIBB COUNTY, GEORGIA", LATEST EDITION. IT IS ASSUMED

THAT ALL EXISTING PIPES ARE CURRENTLY DRAINING PROPERLY. CONTRACTOR SHALL NOTIFY ENGINEER

IF EXISTING CONDITIONS DO NOT SUPPORT THIS ASSUMPTION.

5. ALL DISTURBED AREAS SHALL BE STABILIZED WITH EROSION MATTING AND PERMANENT GRASSING. ALL

SEDIMENTATION AND EROSION BMP'S SHALL BE IN ACCORDANCE WITH THE EROSION AND SEDIMENTATION

CONTROL IN GEORGIA HANDBOOK, LATEST EDITION.

6. CONTRACTOR RESPONSIBLE FOR PROVIDING CONTINUED ACCESS (ONE LANE TO REMAIN OPEN) TO

HOMEOWNERS EFFECTED BY ANY CONSTRUCTION RELATED WORK.

7. PROPOSED HEADWALLS SHALL MATCH THE DESIGN OF THE EXISTING HEADWALLS AND SHALL BE IN

ACCORDANCE WITH GDOT STANDARDS. CONTRACTOR SHALL PROVIDE PRECAST OR POUR IN PLACE

HEADWALLS AS SHOWN ON PLANS TO MATCH EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR

DETERMINING SIZE AND DESIGN OF HEADWALLS. ANY FIELD CHANGES TO HEADWALL LOCATION, DESIGN,

ETC. REQUESTED BY THE CONTRACTOR SHALL BE PRE-APPROVED BY THE ENGINEER AND AT NO

ADDITIONAL COST TO THE OWNER.

8. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS FOR ALL PRECAST OR POUR-IN-PLACE CONCRETE

STRUCTURES.

±55 LF OF 42" DIA. CLASS III

REINFORCED CONCRETE PIPE.

± 4 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

PROPOSED HW-1A. SHALL BE

POUR-IN-PLACE L-SHAPED REINFORCED

CONCRETE HEADWALL WITH 54" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 1-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 54" DIA.

OPENING PER GDOT 1001-B STANDARDS

± 4 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

NOTES:

1. PLEASE REFER TO SUPPLEMENTARY DETAILS FOR HEADWALLS

PROVIDED IN ADDENDUM NO. 1.

2. HEADWALL DESIGN INFORMATION HAS BEEN UPDATED

(ADDENDUM NO. 1). ALL DIMENSIONS HAVE BEEN CONFIRMED

AND CALCULATIONS HAVE BEEN PERFORMED BY A

STRUCTURAL ENGINEER, REGISTERED IN THE STATE OF

GEORGIA. ENGINEER'S SEALS WHO APPEAR ON THIS PAGE ARE

NOT SEALING THE STRUCTURAL DESIGN OF THE HEADWALLS.

REVISED AUGUST 2, 2019: UPDATED INFO AND NOTES ON HEADWALLS (ADDENDUM NO. 1)

AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
X
SChrabuszcz
Rectangle
SChrabuszcz
New Stamp
SChrabuszcz
New Stamp
Page 22: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

EX

IS

TIN

G 60"C

MP

IN

V:369.06

EX

IS

TIN

G 60"C

MP

IN

V:368.31

360

0+00 0+50 0+75

370

380

EXISTING GROUND

ELEVATION

0+25

EXISTING

ROADWAY

APPROX. LOCATION

OF EXISTING 8"DIA.

DIP WATER LINE

1+00

1IN OTP

INV:371.19

6" PVC

INV:378.74

12" CPP

203

-598.40

UTP OHP OHT OHTV

NOW OR FORMERLY

RICKY & DENISE BENNETT

PARCEL G007-0050

DB 9022, PG 306

PB 55, PG 51

NOW OR FORMERLY

RONALD & JULIE WALKER

PARCEL G007-0051

DB 2989, PG 160

3

7

5

3

7

6

3

7

7

378

3

8

0

3

8

1

3

8

0

3

7

5

3

7

3

369

369

3

7

5

3

7

0

3

7

8

380

379

3

7

6

3

7

0

3753

7

1

3

7

4

3

7

2

3

7

3

3

7

4

3

7

33

7

2

3

7

3

3

7

4

EXISTING

INV. 369.06

N

INV:377.58

12" CPP

PROPERTY LINE (TYP.)

T

O

B

E

S

O

F

K

E

E

P

O

IN

T

C

IR

C

L

E

(5

5

'R

/W

)

XX

XX

EXISTING

INV. 368.31

3920 ARKWRIGHT RD.(478) 743-7175

DATE

SHEET OF

SCALE

PROJ. NO.

CULVERTS REPAIR / REPLACEMENT (GROUP 3)

MACON WATER AUTHORITY

FOR

JUNE 2019

5020-023-01

SUITE 101(478) 743-1703(FAX) MACON, GEORGIA 31210

BIBB COUNTY, GEORGIA

13

2018 MACON - BIBB COUNTYWIDE STORMWATER

DWG.

No. 30797PROFESSIONAL

D

A

N

I

E

L

E

.

C

H

E

E

K

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

EDIT

No. 37584PROFESSIONAL

E

R

I

C

P

I

E

RCE

J

A

C

K

S

O

N

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

MWA-2018 SW

2

NOTES:

1. EXISTING CONDITION INFORMATION TAKEN FROM THE "TOPOGRAPHIC SURVEY" PREPARED BY WELLSTON

ASSOCIATES LAND SURVEYORS, LLC, DATE OF SURVEY: MARCH 7, 2016.

2. THE UNDERGROUND UTILITIES SHOWN ON THIS DRAWING WERE COMPILED FROM FIELD OBSERVATIONS

WITHOUT BENEFIT OF EXCAVATION. WELLSTON ASSOCIATES LAND SURVEYORS, LLC DOES NOT

GUARANTEE THAT ALL UTILITIES ARE SHOWN. VERIFICATION OF UTILITIES SHOULD BE MADE BY THE

INDIVIDUAL UTILITY COMPANY PRIOR TO ANY CONSTRUCTION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO CONSTRUCTION. DEPTH OF

ALL EXISTING UTILITIES SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. MATERIALS

FOR ANY REQUIRED WATER OR SEWER SYSTEM RELOCATION WILL BE PROVIDED BY THE MACON WATER

AUTHORITY, BUT INSTALLATION, INCLUDING BYPASS, WILL BE INCIDENTAL TO THE CONSTRUCTION OF THE

INDIVIDUAL PROJECT. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED UTILITY RELOCATIONS.

4. CONTRACTOR WILL BE RESPONSIBLE FOR STORM WATER MANAGEMENT AND TRAFFIC CONTROL IN THE

PROJECT AREA DURING CONSTRUCTION. ALL STORMWATER SHALL BE IN ACCORDANCE WITH THE "LOCAL

STORMWATER DESIGN MANUAL FOR MACON - BIBB COUNTY, GEORGIA", LATEST EDITION. IT IS ASSUMED

THAT ALL EXISTING PIPES ARE CURRENTLY DRAINING PROPERLY. CONTRACTOR SHALL NOTIFY ENGINEER

IF EXISTING CONDITIONS DO NOT SUPPORT THIS ASSUMPTION.

5. ALL DISTURBED AREAS SHALL BE STABILIZED WITH EROSION MATTING AND PERMANENT GRASSING. ALL

SEDIMENTATION AND EROSION BMP'S SHALL BE IN ACCORDANCE WITH THE EROSION AND SEDIMENTATION

CONTROL IN GEORGIA HANDBOOK, LATEST EDITION.

6. CONTRACTOR RESPONSIBLE FOR PROVIDING CONTINUED ACCESS (ONE LANE TO REMAIN OPEN) TO

HOMEOWNERS EFFECTED BY ANY CONSTRUCTION RELATED WORK.

7. PROPOSED HEADWALLS SHALL MATCH THE DESIGN OF THE EXISTING HEADWALLS AND SHALL BE IN

ACCORDANCE WITH GDOT STANDARDS. CONTRACTOR SHALL PROVIDE PRECAST OR POUR IN PLACE

HEADWALLS AS SHOWN ON PLANS TO MATCH EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR

DETERMINING SIZE AND DESIGN OF HEADWALLS. ANY FIELD CHANGES TO HEADWALL LOCATION, DESIGN,

ETC. REQUESTED BY THE CONTRACTOR SHALL BE PRE-APPROVED BY THE ENGINEER AND AT NO

ADDITIONAL COST TO THE OWNER.

8. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS FOR ALL PRECAST OR POUR-IN-PLACE CONCRETE

STRUCTURES.

9. CONTRACTOR TO AVOID FLAGGED TREES ON DOWNSTREAM END OF PROJECT SITE UNLESS ABSOLUTELY

NECESSARY FOR CONSTRUCTION OF THIS CROSSING.

DISCLAIMER:

1. THE DESIGN / ENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED ON THE TOPOGRAPHY,

EXISTING CONDITIONS, OR DESIGNS BY OTHERS AS REFERENCED. SHOULD ANY OF THE EXISTING CONDITIONS

OR TOPOGRAPHY BE FOUND TO BE DIFFERENT OR CHANGED, THE DESIGN ENGINEER THAT PREPARED THIS

PLAN SHOULD BE CONTACTED PRIOR TO CONSTRUCTING / IMPLEMENTING THIS DESIGN, AND TO DETERMINE IF

DESIGN REVISIONS ARE REQUIRED.

2. THE ENGINEER THAT PREPARED THIS DRAWING HAS ASSUMED THAT THE CONSTRUCTION WILL BE PERFORMED

IN ACCORDANCE WITH THE ENGINEERING INTENT AND COMPLETE CONSTRUCTION SPECIFICATIONS WILL BE

PREPARED TO ACCOMPANY THE DRAWINGS. THE ENGINEER EXPECTS THAT HE WILL BE INVOLVED WITH,

PROVIDED AN OPPORTUNITY TO REVIEW, AND INSPECT PRODUCTS AND CONSTRUCTION OF THE

IMPROVEMENTS SHOWN ON THIS PLAN SHEET IN ORDER TO CONFIRM THAT THE CONSTRUCTION OF THE

IMPROVEMENTS ARE INSTALLED IN ACCORDANCE WITH DESIGN CONCEPTS. SHOULD THE DESIGN ENGINEER

NOT BE INVOLVED WITH CONSTRUCTION, HE WILL NOT BE LIABLE FOR CHANGES IN CONDITIONS OR FIELD

CONDITIONS THAT MAY AFFECT THE DESIGN.

1" = 20'

8-2-19

PROJECT 2 - 825 TOBESOFKEE POINT CIRCLE

3755' CONTOUR LINE

STORM SEWER LINE

OVERHEAD POWER, TELEPHONE, TV

ASPHALT

P,T,TV

3751' CONTOUR LINE

GRAPHIC SCALE IN FEET

0 40201020

WATER LINE W

CONTRACTOR TO REMOVE

EXISTING 60" DIA. CMP

±55 LF OF 60" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO

FIELD CONFIRM AND SET GRADE TO

PROVIDE MINIMUM SLOPE OF 1.4%.

CLASS 'A' ASPHALT

PAVEMENT REPLACEMENT

DOUBLE ROW OF SENSITIVE

SILT FENCE (TYPE-C)

(TYP.)

30'

15'

25'

30'

PROPOSED TEMPORARY

CONSTRUCTION EASEMENT

(TO BE CENTERED ON EITHER

SIDE OF PROPOSED PIPE)

PROPOSED PERMANENT

EASEMENT (TO BE CENTERED

ON EITHER SIDE OF PROPOSED

PIPE)

Sd1-S

PLAN VIEW

SCALE: 1"=20'

PROFILE VIEW

SCALE: H:1"=20', V:1"=5'

115 SY OF 15" DIA. RIP-RAP

OUTLET PROTECTION

OP

±55 LF OF 60" DIA.

CLASS III REINFORCED

CONCRETE PIPE.

CONTRACTOR SHALL NOT REMOVE

FLAGGED TREES ON SOUTH SIDE OF ROAD.

IF REMOVAL IS DEEMED NECESSARY,

CONTRACTOR SHALL OBTAIN PRIOR

APPROVAL BY MWA.

PROPOSED HEADWALL 2-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 72" DIA.

OPENING PER GDOT STANDARDS.

± 6 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

±14 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

PROPOSED HEADWALL 2-A. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 72" DIA.

OPENING PER GDOT STANDARDS. MUST

FILL IN INVERT WITH CONCRETE APRON

(TO MATCH THICKNESS OF FOOTING)

REVISED AUGUST 2, 2019: UPDATED INFO AND NOTES ON HEADWALLS (ADDENDUM NO. 1)

PROPOSED HEADWALL 2-A. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 72" DIA.

OPENING PER GDOT STANDARDS. MUST

FILL IN INVERT WITH CONCRETE APRON

(TO MATCH THICKNESS OF FOOTING)

NOTES:

1. PLEASE REFER TO SUPPLEMENTARY DETAILS FOR HEADWALLS

PROVIDED IN ADDENDUM NO. 1.

2. HEADWALL DESIGN INFORMATION HAS BEEN UPDATED

(ADDENDUM NO. 1). ALL DIMENSIONS HAVE BEEN CONFIRMED

AND CALCULATIONS HAVE BEEN PERFORMED BY A

STRUCTURAL ENGINEER, REGISTERED IN THE STATE OF

GEORGIA. ENGINEER'S SEALS WHO APPEAR ON THIS PAGE ARE

NOT SEALING THE STRUCTURAL DESIGN OF THE HEADWALLS.

PROPOSED HEADWALL 2-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 72" DIA.

OPENING PER GDOT STANDARDS.

AutoCAD SHX Text
LEGEND
SChrabuszcz
Rectangle
SChrabuszcz
New Stamp
SChrabuszcz
New Stamp
Page 23: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

66

"W

X

4

8" C

MP

IN

V:3

99

.6

9

EX

IS

TIN

G 6

6"W

X

4

8" C

MP

IN

V:3

97

.4

9

0+00 0+50 0+75

390

400

410

EXISTING

GROUND

ELEVATION

0+25 1+00

EXISTING ROADWAY

APPROX. LOCATION

OF EXISTING 6" DIA.

DIP WATER LINE

1+25 1+50

APPROX. LOCATION

OF EXISTING WATER

SERVICE LINE

NOW OR FORMERLY

JUDSON J. SMITH & FAITH CAGLE

PARCEL K006-0133

DB 9582, PG 365

PB 52, PG 42

1067

1079

218

402.39

GUY

204

404.17

GUY

1070

INV:402.11

15"RCP

INV:401.53

15"RCP

210

-592.51

UTP OHP OHT OHTV

211

-574.59

UTP OHP1 OHT1 OHTV1

212

-589.76

UTP OHP OHT OHTV

213

-589.74

UTP OHP2 OHT2 OHTV2

INV:395.82

60"CMP

215

402.76

GUY

INV:395.86

60"CMP

NOW OR FORMERLY

WAYNE & LINDA MONTGOMERY

PARCEL K006-0132

DB 7901, PG 97

PB 52, PG 42

NOW OR FORMERLY

DONNA A. SMITH &

LORAN DUNCAN SMITH, JR.

PARCEL K006-0123

DB 9235, PG 351

NOW OR FORMERLY

CAREY C. MCPHAIL

PARCEL K006-0302

DB 4020, PG 195

PB 88, PG 955

NOW OR FORMERLY

CAREY C. MCPHAIL

PARCEL K006-0213

DB 4020, PG 194

PB 88, PG 955

NOW OR FORMERLY

HOWARD E. & CAROL S. HIGHTOWER

PARCEL K006-0213

DB 4801, PG 159

PB 52, PG 42

4

0

5

4

0

4

4

0

2

4

0

2

4

0

5

4

0

7

4

0

4

4

0

0

3

9

8

4

0

0

4

0

3

4

0

0

4

0

2

403

405

4

0

7

409

EXISTING

INV. 399.69

ASHLEY HALL ROAD (55' R/W)

XX

XX

EXISTING 15" DIA. CMP

EXISTING

INV. 397.49

3920 ARKWRIGHT RD.(478) 743-7175

DATE

SHEET OF

SCALE

PROJ. NO.

CULVERTS REPAIR / REPLACEMENT (GROUP 3)

MACON WATER AUTHORITY

FOR

JUNE 2019

5020-023-01

SUITE 101(478) 743-1703(FAX) MACON, GEORGIA 31210

BIBB COUNTY, GEORGIA

13

2018 MACON - BIBB COUNTYWIDE STORMWATER

DWG.

No. 30797PROFESSIONAL

D

A

N

I

E

L

E

.

C

H

E

E

K

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

EDIT

No. 37584PROFESSIONAL

E

R

I

C

P

I

E

RCE

J

A

C

K

S

O

N

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

MWA-2018 SW

3

1" = 20'

8-2-19

PROJECT 3 - 1067 ASHLEY HALL ROAD

PLAN VIEW

SCALE: 1"=20'

CONTRACTOR TO REMOVE

EXISTING CMP

DOUBLE ROW OF SENSITIVE

SILT FENCE (TYPE-C)

(TYP.)

Sd1-S

±90 LF OF 48"X66" ELLIPTICAL CLASS

III REINFORCED CONCRETE PIPE.

CONTRACTOR TO FIELD CONFIRM

AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 2.3%.

CLASS 'A' ASPHALT

PAVEMENT REPLACEMENT

PROFILE VIEW

SCALE: H:1"=20', V:1"=5'

405

IRON PIN FOUND

5' CONTOUR LINE

UTILITY POLE

GUY WIRE

WATER METER

WATER VALVE

FIRE HYDRANT

IRRIGATION CONTROL VALVE

STORM SEWER LINE

OVERHEAD POWER, TELEPHONE

AND CATV

ASPHALT

CONCRETE

P,T,TV

WATER LINE W

MAIL BOX

HOSE BIB HB

4091' CONTOUR LINE

N

GRAPHIC SCALE IN FEET

0 40201020

CLASS 'A' CONCRETE

DRIVEWAY PAVEMENT

REPLACEMENT

PROPOSED TEMPORARY

CONSTRUCTION EASEMENT

(TO BE CENTERED ON EITHER

SIDE OF PROPOSED PIPE)

5

0

'

3

0

'

PROPOSED TEMPORARY

CONSTRUCTION EASEMENT

±

3

1

'

3

0

'

DISCLAIMER:

1. THE DESIGN / ENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED ON THE TOPOGRAPHY,

EXISTING CONDITIONS, OR DESIGNS BY OTHERS AS REFERENCED. SHOULD ANY OF THE EXISTING CONDITIONS

OR TOPOGRAPHY BE FOUND TO BE DIFFERENT OR CHANGED, THE DESIGN ENGINEER THAT PREPARED THIS

PLAN SHOULD BE CONTACTED PRIOR TO CONSTRUCTING / IMPLEMENTING THIS DESIGN, AND TO DETERMINE IF

DESIGN REVISIONS ARE REQUIRED.

2. THE ENGINEER THAT PREPARED THIS DRAWING HAS ASSUMED THAT THE CONSTRUCTION WILL BE PERFORMED

IN ACCORDANCE WITH THE ENGINEERING INTENT AND COMPLETE CONSTRUCTION SPECIFICATIONS WILL BE

PREPARED TO ACCOMPANY THE DRAWINGS. THE ENGINEER EXPECTS THAT HE WILL BE INVOLVED WITH,

PROVIDED AN OPPORTUNITY TO REVIEW, AND INSPECT PRODUCTS AND CONSTRUCTION OF THE

IMPROVEMENTS SHOWN ON THIS PLAN SHEET IN ORDER TO CONFIRM THAT THE CONSTRUCTION OF THE

IMPROVEMENTS ARE INSTALLED IN ACCORDANCE WITH DESIGN CONCEPTS. SHOULD THE DESIGN ENGINEER

NOT BE INVOLVED WITH CONSTRUCTION, HE WILL NOT BE LIABLE FOR CHANGES IN CONDITIONS OR FIELD

CONDITIONS THAT MAY AFFECT THE DESIGN.

90 SY OF 12" DIA. RIP-RAP

OUTLET PROTECTION

OP

NOTES:

1. EXISTING CONDITION INFORMATION TAKEN FROM THE "TOPOGRAPHIC SURVEY" PREPARED BY WELLSTON

ASSOCIATES LAND SURVEYORS, LLC, DATE OF SURVEY: MARCH 7, 2016.

2. THE UNDERGROUND UTILITIES SHOWN ON THIS DRAWING WERE COMPILED FROM FIELD OBSERVATIONS

WITHOUT BENEFIT OF EXCAVATION. WELLSTON ASSOCIATES LAND SURVEYORS, LLC DOES NOT

GUARANTEE THAT ALL UTILITIES ARE SHOWN. VERIFICATION OF UTILITIES SHOULD BE MADE BY THE

INDIVIDUAL UTILITY COMPANY PRIOR TO ANY CONSTRUCTION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO CONSTRUCTION. DEPTH OF

ALL EXISTING UTILITIES SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. MATERIALS

FOR ANY REQUIRED WATER OR SEWER SYSTEM RELOCATION WILL BE PROVIDED BY THE MACON WATER

AUTHORITY, BUT INSTALLATION, INCLUDING BYPASS, WILL BE INCIDENTAL TO THE CONSTRUCTION OF THE

INDIVIDUAL PROJECT. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED UTILITY RELOCATIONS.

4. CONTRACTOR WILL BE RESPONSIBLE FOR STORM WATER MANAGEMENT AND TRAFFIC CONTROL IN THE

PROJECT AREA DURING CONSTRUCTION. ALL STORMWATER SHALL BE IN ACCORDANCE WITH THE "LOCAL

STORMWATER DESIGN MANUAL FOR MACON - BIBB COUNTY, GEORGIA", LATEST EDITION. IT IS ASSUMED

THAT ALL EXISTING PIPES ARE CURRENTLY DRAINING PROPERLY. CONTRACTOR SHALL NOTIFY ENGINEER

IF EXISTING CONDITIONS DO NOT SUPPORT THIS ASSUMPTION.

5. ALL DISTURBED AREAS SHALL BE STABILIZED WITH EROSION MATTING AND PERMANENT GRASSING. ALL

SEDIMENTATION AND EROSION BMP'S SHALL BE IN ACCORDANCE WITH THE EROSION AND SEDIMENTATION

CONTROL IN GEORGIA HANDBOOK, LATEST EDITION.

6. CONTRACTOR RESPONSIBLE FOR PROVIDING CONTINUED ACCESS (ONE LANE TO REMAIN OPEN) TO

HOMEOWNERS EFFECTED BY ANY CONSTRUCTION RELATED WORK.

7. PROPOSED HEADWALLS SHALL MATCH THE DESIGN OF THE EXISTING HEADWALLS AND SHALL BE IN

ACCORDANCE WITH GDOT STANDARDS. CONTRACTOR SHALL PROVIDE PRECAST OR POUR IN PLACE

HEADWALLS AS SHOWN ON PLANS TO MATCH EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR

DETERMINING SIZE AND DESIGN OF HEADWALLS. ANY FIELD CHANGES TO HEADWALL LOCATION, DESIGN,

ETC. REQUESTED BY THE CONTRACTOR SHALL BE PRE-APPROVED BY THE ENGINEER AND AT NO

ADDITIONAL COST TO THE OWNER.

8. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS FOR ALL PRECAST OR POUR-IN-PLACE CONCRETE

STRUCTURES.

±

1

1

'

±90 LF OF 48"X66" ELLIPTICAL CLASS

III REINFORCED CONCRETE PIPE.

CONTRACTOR TO FIELD CONFIRM

AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 2.3%.

± 4 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

± 4 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

NOTES:

1. PLEASE REFER TO SUPPLEMENTARY DETAILS FOR HEADWALLS

PROVIDED IN ADDENDUM NO. 1.

2. HEADWALL DESIGN INFORMATION HAS BEEN UPDATED

(ADDENDUM NO. 1). ALL DIMENSIONS HAVE BEEN CONFIRMED

AND CALCULATIONS HAVE BEEN PERFORMED BY A

STRUCTURAL ENGINEER, REGISTERED IN THE STATE OF

GEORGIA. ENGINEER'S SEALS WHO APPEAR ON THIS PAGE ARE

NOT SEALING THE STRUCTURAL DESIGN OF THE HEADWALLS.

REVISED AUGUST 2, 2019: UPDATED INFO AND NOTES ON HEADWALLS (ADDENDUM NO. 1)

PROPOSED HEADWALL 3-A. SHALL BE

POUR-IN-PLACE 45° WINGWALL

REINFORCED CONCRETE HEADWALL

WITH 60" X 78" ELLIPTICAL OPENING PER

GDOT STANDARDS.

PROPOSED HEADWALL 3-A. SHALL BE

POUR-IN-PLACE 45° WINGWALL

REINFORCED CONCRETE HEADWALL

WITH 60" X 78" ELLIPTICAL OPENING PER

GDOT STANDARDS.

PROPOSED HEADWALL 3-B. SHALL BE

POUR-IN-PLACE 45° WINGWALL

REINFORCED CONCRETE HEADWALL

WITH 60" X 78" ELLIPTICAL OPENING PER

GDOT STANDARDS. HEADWALL SHALL

INCORPORATE EXISTING 15" DIA.

STORMWATER PIPE.

PROPOSED HEADWALL 3-B. SHALL BE

POUR-IN-PLACE 45° WINGWALL

REINFORCED CONCRETE HEADWALL

WITH 60" X 78" ELLIPTICAL OPENING PER

GDOT STANDARDS. HEADWALL SHALL

INCORPORATE EXISTING 15" DIA.

STORMWATER PIPE.

AutoCAD SHX Text
H
AutoCAD SHX Text
Y
AutoCAD SHX Text
D
AutoCAD SHX Text
LEGEND
SChrabuszcz
Rectangle
SChrabuszcz
New Stamp
SChrabuszcz
New Stamp
Page 24: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

A

P

P

R

O

X

I

M

A

T

E

F

L

O

O

D

Z

O

N

E

Z

O

N

E

X

Z

O

N

E

A

E

A

P

P

R

O

X

I

M

A

T

E

F

L

O

O

D

Z

O

N

E

F

L

O

O

D

W

A

Y

AP

PR

OX

IM

AT

E F

LO

OD

Z

ON

E

ZO

NE

A

E

ZO

NE

X

1/2"REBAR

457

408.13

UTP OHP OHT

SSMH

RIM: 408.29

INV A:404.81

A

B

8

"

D

I

P

PARCEL:L051-0121

111 GEORGETOWN CT

NOW OR FORMERLY

STEVEN H & TRACEY L SCHWARTZ

DB 2899, PG 189

PB 75, PG 73

PARCEL:L051-0120

109 GEORGETOWN CT

NOW OR FORMERLY

JAMES O. JR & ZENEPHIA A. GLORE

DB 1754, PG 653

PB 87, PG 720

PARCEL:L052-0257

NOW OR FORMERLY

TATTNAL SQUARE BAPTIST CHURCH

DB 2780, PG 240

PB 87, PG 720

PARCEL:L044-0156

800 WESLEYAN DR

NOW OR FORMERLY

HARLAN L HIGHBAUGH

DB 2928, PG 48

PB 88, PG 404

PARCEL:L043-0180

105 TROJAN TRL

NOW OR FORMERLY

RIVERA RENE O RAMIREZ

DB 10139, PG 1

PB 86, PG 47

EXISTING 78" X 54"

ELLIPTICAL CMP

EXISTING

INV. 405.49

XX

XX

TROJAN TRAIL (55' R/W)

EXISTING

INV. 405.96

EX

IS

TIN

G H

EA

DW

ALL

IN

V:405.96

EX

IS

TIN

G H

EA

DW

ALL

IN

V:405.49

0+00 0+25 0+50 0+75

400

410

420

EXISTING

GROUND

ELEVATION

EXISTING

ROADWAY

1+00

APPROX. LOCATION

OF EXISTING 6"DIA.

DIP WATER LINE

3920 ARKWRIGHT RD.(478) 743-7175

DATE

SHEET OF

SCALE

PROJ. NO.

CULVERTS REPAIR / REPLACEMENT (GROUP 3)

MACON WATER AUTHORITY

FOR

JUNE 2019

5020-023-01

SUITE 101(478) 743-1703(FAX) MACON, GEORGIA 31210

BIBB COUNTY, GEORGIA

13

2018 MACON - BIBB COUNTYWIDE STORMWATER

DWG.

No. 30797PROFESSIONAL

D

A

N

I

E

L

E

.

C

H

E

E

K

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

EDIT

No. 37584PROFESSIONAL

E

R

I

C

P

I

E

RCE

J

A

C

K

S

O

N

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

MWA-2018 SW

4

1" = 20'

8-2-19

PROJECT 4 - 105 TROJAN TRAIL

4305' CONTOUR LINE

SANITARY SEWER MANHOLE

WATER METER

STORM SEWER LINE

SANITARY SEWER LINE

UNDERGROUND POWER

ASPHALT

LEGEND

UP

SAN

UNDERGROUND TELEPHONE UT

WATER LINE W

CLEAN OUT

TRANSFORMER

GAS LINE

4281' CONTOUR LINE

PLAN VIEW

SCALE: 1"=20'

CONTRACTOR TO REMOVE

EXISTING CMP

DOUBLE ROW OF SENSITIVE

SILT FENCE (TYPE-C)

(TYP.)

Sd1-S

±53 LF OF 78"X54" ELLIPTICAL CLASS

III REINFORCED CONCRETE PIPE.

CONTRACTOR TO FIELD CONFIRM

AND SET GRADE TO MATCH EXISTING

SLOPE

CLASS 'A' ASPHALT

PAVEMENT REPLACEMENT

N

GRAPHIC SCALE IN FEET

0 40201020

3

0

'

PROPOSED PERMANENT

EASEMENT (TO BE CENTERED

ON EITHER SIDE OF PROPOSED

PIPE)

PROPOSED PERMANENT

EASEMENT (TO BE

CENTERED ON EITHER SIDE

OF PROPOSED PIPE)

DISCLAIMER:

1. THE DESIGN / ENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED ON THE TOPOGRAPHY,

EXISTING CONDITIONS, OR DESIGNS BY OTHERS AS REFERENCED. SHOULD ANY OF THE EXISTING CONDITIONS

OR TOPOGRAPHY BE FOUND TO BE DIFFERENT OR CHANGED, THE DESIGN ENGINEER THAT PREPARED THIS

PLAN SHOULD BE CONTACTED PRIOR TO CONSTRUCTING / IMPLEMENTING THIS DESIGN, AND TO DETERMINE IF

DESIGN REVISIONS ARE REQUIRED.

2. THE ENGINEER THAT PREPARED THIS DRAWING HAS ASSUMED THAT THE CONSTRUCTION WILL BE PERFORMED

IN ACCORDANCE WITH THE ENGINEERING INTENT AND COMPLETE CONSTRUCTION SPECIFICATIONS WILL BE

PREPARED TO ACCOMPANY THE DRAWINGS. THE ENGINEER EXPECTS THAT HE WILL BE INVOLVED WITH,

PROVIDED AN OPPORTUNITY TO REVIEW, AND INSPECT PRODUCTS AND CONSTRUCTION OF THE

IMPROVEMENTS SHOWN ON THIS PLAN SHEET IN ORDER TO CONFIRM THAT THE CONSTRUCTION OF THE

IMPROVEMENTS ARE INSTALLED IN ACCORDANCE WITH DESIGN CONCEPTS. SHOULD THE DESIGN ENGINEER

NOT BE INVOLVED WITH CONSTRUCTION, HE WILL NOT BE LIABLE FOR CHANGES IN CONDITIONS OR FIELD

CONDITIONS THAT MAY AFFECT THE DESIGN.

90 SY OF 12" DIA. RIP-RAP

OUTLET PROTECTION

OP

±

4

3

'

±

2

4

'

±

2

4

'

±

4

3

'

3

0

'

NOTES:

1. EXISTING CONDITION INFORMATION TAKEN FROM THE "TOPOGRAPHIC SURVEY" PREPARED BY WELLSTON

ASSOCIATES LAND SURVEYORS, LLC, DATE OF SURVEY: DECEMBER 2018.

2. THE UNDERGROUND UTILITIES SHOWN ON THIS DRAWING WERE COMPILED FROM FIELD OBSERVATIONS

WITHOUT BENEFIT OF EXCAVATION. WELLSTON ASSOCIATES LAND SURVEYORS, LLC DOES NOT

GUARANTEE THAT ALL UTILITIES ARE SHOWN. VERIFICATION OF UTILITIES SHOULD BE MADE BY THE

INDIVIDUAL UTILITY COMPANY PRIOR TO ANY CONSTRUCTION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO CONSTRUCTION. DEPTH OF

ALL EXISTING UTILITIES SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. MATERIALS

FOR ANY REQUIRED WATER OR SEWER SYSTEM RELOCATION WILL BE PROVIDED BY THE MACON WATER

AUTHORITY, BUT INSTALLATION, INCLUDING BYPASS, WILL BE INCIDENTAL TO THE CONSTRUCTION OF THE

INDIVIDUAL PROJECT. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED UTILITY RELOCATIONS.

4. CONTRACTOR WILL BE RESPONSIBLE FOR STORM WATER MANAGEMENT AND TRAFFIC CONTROL IN THE

PROJECT AREA DURING CONSTRUCTION. ALL STORMWATER SHALL BE IN ACCORDANCE WITH THE "LOCAL

STORMWATER DESIGN MANUAL FOR MACON - BIBB COUNTY, GEORGIA", LATEST EDITION. IT IS ASSUMED

THAT ALL EXISTING PIPES ARE CURRENTLY DRAINING PROPERLY. CONTRACTOR SHALL NOTIFY ENGINEER

IF EXISTING CONDITIONS DO NOT SUPPORT THIS ASSUMPTION.

5. ALL DISTURBED AREAS SHALL BE STABILIZED WITH EROSION MATTING AND PERMANENT GRASSING. ALL

SEDIMENTATION AND EROSION BMP'S SHALL BE IN ACCORDANCE WITH THE EROSION AND SEDIMENTATION

CONTROL IN GEORGIA HANDBOOK, LATEST EDITION.

6. CONTRACTOR RESPONSIBLE FOR PROVIDING CONTINUED ACCESS (ONE LANE TO REMAIN OPEN) TO

HOMEOWNERS EFFECTED BY ANY CONSTRUCTION RELATED WORK.

7. PROPOSED HEADWALLS SHALL MATCH THE DESIGN OF THE EXISTING HEADWALLS AND SHALL BE IN

ACCORDANCE WITH GDOT STANDARDS. CONTRACTOR SHALL PROVIDE PRECAST OR POUR IN PLACE

HEADWALLS AS SHOWN ON PLANS TO MATCH EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR

DETERMINING SIZE AND DESIGN OF HEADWALLS. ANY FIELD CHANGES TO HEADWALL LOCATION, DESIGN,

ETC. REQUESTED BY THE CONTRACTOR SHALL BE PRE-APPROVED BY THE ENGINEER AND AT NO

ADDITIONAL COST TO THE OWNER.

8. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS FOR ALL PRECAST OR POUR-IN-PLACE CONCRETE

STRUCTURES.

±53 LF OF 78"X54" ELLIPTICAL CLASS

III REINFORCED CONCRETE PIPE.

CONTRACTOR TO FIELD CONFIRM

AND SET GRADE TO MATCH EXISTING

SLOPE

PROFILE VIEW

SCALE: H:1"=20', V:1"=5'

± 2 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

± 2 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

NOTES:

1. PLEASE REFER TO SUPPLEMENTARY DETAILS FOR HEADWALLS

PROVIDED IN ADDENDUM NO. 1.

2. HEADWALL DESIGN INFORMATION HAS BEEN UPDATED

(ADDENDUM NO. 1). ALL DIMENSIONS HAVE BEEN CONFIRMED

AND CALCULATIONS HAVE BEEN PERFORMED BY A

STRUCTURAL ENGINEER, REGISTERED IN THE STATE OF

GEORGIA. ENGINEER'S SEALS WHO APPEAR ON THIS PAGE ARE

NOT SEALING THE STRUCTURAL DESIGN OF THE HEADWALLS.

REVISED AUGUST 2, 2019: UPDATED INFO AND NOTES ON HEADWALLS (ADDENDUM NO. 1)

PROPOSED HEADWALL 4-A. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 66" x 90"

ELLIPTICAL OPENING PER GDOT STANDARDS.

MUST FILL IN INVERT WITH CONCRETE APRON

(TO MATCH THICKNESS OF FOOTING)

PROPOSED HEADWALL 4-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 66" x 90"

ELLIPTICAL OPENING PER GDOT STANDARDS.

MUST FILL IN INVERT WITH CONCRETE APRON

(TO MATCH THICKNESS OF FOOTING)

PROPOSED HEADWALL 4-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 66" x 90"

ELLIPTICAL OPENING PER GDOT STANDARDS.

MUST FILL IN INVERT WITH CONCRETE APRON

(TO MATCH THICKNESS OF FOOTING)

PROPOSED HEADWALL 4-A. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 66" x 90"

ELLIPTICAL OPENING PER GDOT STANDARDS.

MUST FILL IN INVERT WITH CONCRETE APRON

(TO MATCH THICKNESS OF FOOTING)

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
X
SChrabuszcz
Rectangle
SChrabuszcz
New Stamp
SChrabuszcz
New Stamp
Page 25: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

EX

IS

TIN

G C

MP

IN

V:4

67

.8

4

0+00 0+50

360

370

380

EXISTING

GROUND

ELEVATION

0+25

EX

IS

TIN

G C

MP

IN

V:46

6.0

0

APPROX. LOCATION OF

EXISTING GAS LINE

1+00

EXISTING

ROADWAY

APPROX. LOCATION OF

EXISTING 6" DIA. DIP

WATERLINE

1/2"REBAR DIST

ANGLE IRON

1/2" REBAR

233

-509.30

UTP OHP OHTV

234

-513.77

UTP OHP OHTV

NOW OR FORMERLY

EARL M. & DOLLIE DAVIS

PARCEL F010-0043

DB 1606, PG 699

PB 55, PG 60

NOW OR FORMERLY

RICHARD H. & LOTTE MCNATT

PARCEL G010-0014

DB 1620, PG 39

PB 55, PG 60

NOW OR FORMERLY

WILLIAM G. SR. & DEBRA Z. SOWELL

PARCEL G010-0037

DB 1621, PG 747

PB 55, PG 60

467

468

4

6

7

4

6

94

7

0

4

6

8

466

4

7

0

469

4

7

0

4

7

1

EXISTING

INV. 467.84

W

E

S

T

P

O

IN

T

C

IR

C

L

E

(

5

5

'R

/W

)

X

X

X

X

EXISTING 10'

DRAINAGE

EASEMENT

EXISTING

INV. 466.00

5

1" = 20'

8-2-19

PROJECT 5 - 3676 WEST POINT CIRCLE

PLAN VIEW

SCALE: 1"=20'

CONTRACTOR TO REMOVE

EXISTING 24" DIA. CMP

DOUBLE ROW OF SENSITIVE

SILT FENCE (TYPE-C)

(TYP.)

Sd1-S

CLASS 'A' ASPHALT

PAVEMENT REPLACEMENT

PROFILE VIEW

SCALE: H:1"=20', V:1"=5'

PROJECT NO. 3 WAS COMPLETED

DURING THE PREVIOUS SPLOST REPAIR

WORK. THIS PROJECT IS NOT INCLUDED

IN THIS PROJECT SCOPE.

950

IRON PIN FOUND

PROPERTY LINE

BUILDING SETBACK LINE

5' CONTOUR LINE

OVERHEAD POWER, TELEPHONE AND CATVP,T,TV

WATER LINE W

GAS LINE G

PINE TREE

UNDERGROUND TELEPHONE UT

9481' CONTOUR LINE

N

ASPHALT

±35 LF OF 24" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 5.25%.

DISCLAIMER:

1. THE DESIGN / ENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED ON THE TOPOGRAPHY,

EXISTING CONDITIONS, OR DESIGNS BY OTHERS AS REFERENCED. SHOULD ANY OF THE EXISTING CONDITIONS

OR TOPOGRAPHY BE FOUND TO BE DIFFERENT OR CHANGED, THE DESIGN ENGINEER THAT PREPARED THIS

PLAN SHOULD BE CONTACTED PRIOR TO CONSTRUCTING / IMPLEMENTING THIS DESIGN, AND TO DETERMINE IF

DESIGN REVISIONS ARE REQUIRED.

2. THE ENGINEER THAT PREPARED THIS DRAWING HAS ASSUMED THAT THE CONSTRUCTION WILL BE PERFORMED

IN ACCORDANCE WITH THE ENGINEERING INTENT AND COMPLETE CONSTRUCTION SPECIFICATIONS WILL BE

PREPARED TO ACCOMPANY THE DRAWINGS. THE ENGINEER EXPECTS THAT HE WILL BE INVOLVED WITH,

PROVIDED AN OPPORTUNITY TO REVIEW, AND INSPECT PRODUCTS AND CONSTRUCTION OF THE

IMPROVEMENTS SHOWN ON THIS PLAN SHEET IN ORDER TO CONFIRM THAT THE CONSTRUCTION OF THE

IMPROVEMENTS ARE INSTALLED IN ACCORDANCE WITH DESIGN CONCEPTS. SHOULD THE DESIGN ENGINEER

NOT BE INVOLVED WITH CONSTRUCTION, HE WILL NOT BE LIABLE FOR CHANGES IN CONDITIONS OR FIELD

CONDITIONS THAT MAY AFFECT THE DESIGN.

3920 ARKWRIGHT RD.(478) 743-7175

DATE

SHEET OF

SCALE

PROJ. NO.

CULVERTS REPAIR / REPLACEMENT (GROUP 3)

MACON WATER AUTHORITY

FOR

JUNE 2019

5020-023-01

SUITE 101(478) 743-1703(FAX) MACON, GEORGIA 31210

BIBB COUNTY, GEORGIA

13

2018 MACON - BIBB COUNTYWIDE STORMWATER

DWG.

No. 30797PROFESSIONAL

D

A

N

I

E

L

E

.

C

H

E

E

K

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

EDIT

No. 37584PROFESSIONAL

E

R

I

C

P

I

E

RCE

J

A

C

K

S

O

N

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

MWA-2018 SW

20 SY OF 6" DIA. RIP-RAP

OUTLET PROTECTION

OP

NOTES:

1. EXISTING CONDITION INFORMATION TAKEN FROM THE "TOPOGRAPHIC SURVEY" PREPARED BY WELLSTON

ASSOCIATES LAND SURVEYORS, LLC, DATE OF SURVEY: MARCH 7, 2016.

2. THE UNDERGROUND UTILITIES SHOWN ON THIS DRAWING WERE COMPILED FROM FIELD OBSERVATIONS

WITHOUT BENEFIT OF EXCAVATION. WELLSTON ASSOCIATES LAND SURVEYORS, LLC DOES NOT

GUARANTEE THAT ALL UTILITIES ARE SHOWN. VERIFICATION OF UTILITIES SHOULD BE MADE BY THE

INDIVIDUAL UTILITY COMPANY PRIOR TO ANY CONSTRUCTION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO CONSTRUCTION. DEPTH OF

ALL EXISTING UTILITIES SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. MATERIALS

FOR ANY REQUIRED WATER OR SEWER SYSTEM RELOCATION WILL BE PROVIDED BY THE MACON WATER

AUTHORITY, BUT INSTALLATION, INCLUDING BYPASS, WILL BE INCIDENTAL TO THE CONSTRUCTION OF THE

INDIVIDUAL PROJECT. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED UTILITY RELOCATIONS.

4. CONTRACTOR WILL BE RESPONSIBLE FOR STORM WATER MANAGEMENT AND TRAFFIC CONTROL IN THE

PROJECT AREA DURING CONSTRUCTION. ALL STORMWATER SHALL BE IN ACCORDANCE WITH THE "LOCAL

STORMWATER DESIGN MANUAL FOR MACON - BIBB COUNTY, GEORGIA", LATEST EDITION. IT IS ASSUMED

THAT ALL EXISTING PIPES ARE CURRENTLY DRAINING PROPERLY. CONTRACTOR SHALL NOTIFY ENGINEER

IF EXISTING CONDITIONS DO NOT SUPPORT THIS ASSUMPTION.

5. ALL DISTURBED AREAS SHALL BE STABILIZED WITH EROSION MATTING AND PERMANENT GRASSING. ALL

SEDIMENTATION AND EROSION BMP'S SHALL BE IN ACCORDANCE WITH THE EROSION AND SEDIMENTATION

CONTROL IN GEORGIA HANDBOOK, LATEST EDITION.

6. CONTRACTOR RESPONSIBLE FOR PROVIDING CONTINUED ACCESS (ONE LANE TO REMAIN OPEN) TO

HOMEOWNERS EFFECTED BY ANY CONSTRUCTION RELATED WORK.

7. PROPOSED HEADWALLS SHALL MATCH THE DESIGN OF THE EXISTING HEADWALLS AND SHALL BE IN

ACCORDANCE WITH GDOT STANDARDS. CONTRACTOR SHALL PROVIDE PRECAST OR POUR IN PLACE

HEADWALLS AS SHOWN ON PLANS TO MATCH EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR

DETERMINING SIZE AND DESIGN OF HEADWALLS. ANY FIELD CHANGES TO HEADWALL LOCATION, DESIGN,

ETC. REQUESTED BY THE CONTRACTOR SHALL BE PRE-APPROVED BY THE ENGINEER AND AT NO

ADDITIONAL COST TO THE OWNER.

8. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS FOR ALL PRECAST OR POUR-IN-PLACE CONCRETE

STRUCTURES.

±35 LF OF 24" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 5.25%.

PROPOSED HEADWALL 5-A. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 36" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 5-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 36" DIA.

OPENING PER GDOT 1001-B STANDARDS

CONTRACTOR TO RE-GRADE AND

RE-WORK BACKFILL BEHIND HEADWALL

TO PROMOTE DRAINAGE AROUND

HEADWALL AND PREVENT EROSION AND

UNDERMINING OF HEADWALL

± 3 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

PROPOSED HEADWALL 5-A. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 36" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 5-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 36" DIA.

OPENING PER GDOT 1001-B STANDARDS

NOTES:

1. PLEASE REFER TO SUPPLEMENTARY DETAILS FOR HEADWALLS

PROVIDED IN ADDENDUM NO. 1.

2. HEADWALL DESIGN INFORMATION HAS BEEN UPDATED

(ADDENDUM NO. 1). ALL DIMENSIONS HAVE BEEN CONFIRMED

AND CALCULATIONS HAVE BEEN PERFORMED BY A

STRUCTURAL ENGINEER, REGISTERED IN THE STATE OF

GEORGIA. ENGINEER'S SEALS WHO APPEAR ON THIS PAGE ARE

NOT SEALING THE STRUCTURAL DESIGN OF THE HEADWALLS.

REVISED AUGUST 2, 2019: UPDATED INFO AND NOTES ON HEADWALLS (ADDENDUM NO. 1)

AutoCAD SHX Text
LEGEND
SChrabuszcz
Rectangle
SChrabuszcz
New Stamp
SChrabuszcz
New Stamp
Page 26: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

1/2" REBAR

INV:479.89

24"CMP

235

-510.61

UTP OHP OHT OHTV

SSMH (ASPHALTED)

RIM: 483.60

4

8

9

4

8

8

4

8

7

486

485

484

4

8

3

4

8

2

4

8

1

4

8

5

4

8

4

483

4

8

3

4

8

4

4

8

2

4

8

1

4

8

0

4

7

9

4

7

8

4

7

7

4

7

5

4

7

8

4

7

9

4

8

0

4

8

1

4

8

2

4

8

0

482

4

7

8

4

7

9

4

8

0

4

8

1

4

8

2

4

8

3

4

8

4

4

8

3

4

8

2

4

8

1

N

INV:478.23

24"CMP

EXISTING INV:477.46

EXISTING INV:478.66

EXISTING

INV:475.99

W

O

O

D

F

I

E

L

D

D

R

I

V

E

(

8

0

'

R

/

W

)

M

A

C

O

N

W

E

S

T

D

R

I

V

E

(

6

0

'

R

/

W

)

X

X

X

X

X

X

EXISTING

INV:475.04

EX

IS

TIN

G

42" X

28" C

MP

IN

V:475.04

EX

IS

TIN

G

42" X

28" C

MP

IN

V:475.99

0+00 0+50 0+75

470

480

490

EXISTING

GROUND

ELEVATION

0+25 1+00

EXISTING ROADWAY

APPROX. LOCATION

OF EXISTING 8" DIA.

WATER LINE

APPROX. LOCATION OF

EXISTING GAS LINE

APPROX. LOCATION OF

EXISTING SANITARY

SEWER LINE

EX

IS

TIN

G

18" C

MP

IN

V:477.46

EX

IS

TIN

G

18" C

MP

IN

V:478.66

0+00 0+50 0+75

470

480

490

EXISTING

GROUND

ELEVATION

0+25 1+00

EXISTING ROADWAY

APPROX. LOCATION OF

EXISTING GAS LINE

APPROX. LOCATION

OF EXISTING 8" DIA.

WATER LINE

3920 ARKWRIGHT RD.(478) 743-7175

DATE

SHEET OF

SCALE

PROJ. NO.

CULVERTS REPAIR / REPLACEMENT (GROUP 3)

MACON WATER AUTHORITY

FOR

JUNE 2019

5020-023-01

SUITE 101(478) 743-1703(FAX) MACON, GEORGIA 31210

BIBB COUNTY, GEORGIA

13

2018 MACON - BIBB COUNTYWIDE STORMWATER

DWG.

No. 30797PROFESSIONAL

D

A

N

I

E

L

E

.

C

H

E

E

K

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

EDIT

No. 37584PROFESSIONAL

E

R

I

C

P

I

E

RCE

J

A

C

K

S

O

N

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

MWA-2018 SW

7

1" = 20'

8-2-19

PLAN VIEW

SCALE: 1"=20'

CONTRACTOR TO REMOVE

EXISTING 42" X 28" CMP

CLASS "A" ASPHALT

PAVEMENT REPLACEMENT

DOUBLE ROW OF SENSITIVE

SILT FENCE (TYPE-C)

(TYP.)

Sd1-S

PROFILE VIEW - 42" DIA

SCALE: H:1"=20', V:1"=5'

480

IRON PIN FOUND

PROPERTY LINE

5' CONTOUR LINE

SANITARY SEWER MANHOLE

UTILITY POLE

STORM SEWER LINE

SANITARY SEWER LINE

OVERHEAD POWER, TELEPHONE

AND CATV

ASPHALT

P,T,TV

SAN

LEGEND

4791' CONTOUR LINE

GRAPHIC SCALE IN FEET

0 40201020

±61 LF OF 42" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 1.4%.

DISCLAIMER:

1. THE DESIGN / ENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED ON THE TOPOGRAPHY,

EXISTING CONDITIONS, OR DESIGNS BY OTHERS AS REFERENCED. SHOULD ANY OF THE EXISTING CONDITIONS

OR TOPOGRAPHY BE FOUND TO BE DIFFERENT OR CHANGED, THE DESIGN ENGINEER THAT PREPARED THIS

PLAN SHOULD BE CONTACTED PRIOR TO CONSTRUCTING / IMPLEMENTING THIS DESIGN, AND TO DETERMINE IF

DESIGN REVISIONS ARE REQUIRED.

2. THE ENGINEER THAT PREPARED THIS DRAWING HAS ASSUMED THAT THE CONSTRUCTION WILL BE PERFORMED

IN ACCORDANCE WITH THE ENGINEERING INTENT AND COMPLETE CONSTRUCTION SPECIFICATIONS WILL BE

PREPARED TO ACCOMPANY THE DRAWINGS. THE ENGINEER EXPECTS THAT HE WILL BE INVOLVED WITH,

PROVIDED AN OPPORTUNITY TO REVIEW, AND INSPECT PRODUCTS AND CONSTRUCTION OF THE

IMPROVEMENTS SHOWN ON THIS PLAN SHEET IN ORDER TO CONFIRM THAT THE CONSTRUCTION OF THE

IMPROVEMENTS ARE INSTALLED IN ACCORDANCE WITH DESIGN CONCEPTS. SHOULD THE DESIGN ENGINEER

NOT BE INVOLVED WITH CONSTRUCTION, HE WILL NOT BE LIABLE FOR CHANGES IN CONDITIONS OR FIELD

CONDITIONS THAT MAY AFFECT THE DESIGN.

PROJECT 10 - 3760 WOODFIELD DRIVE

CONTRACTOR TO REMOVE

EXISTING 18" DIA. CMP

±57 LF OF 18" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 2.1%.

200 SY OF 18" DIA. RIP-RAP

OUTLET PROTECTION

OP

50 SY OF 9" DIA. RIP-RAP

OUTLET PROTECTION

OP

NOTES:

1. EXISTING CONDITION INFORMATION TAKEN FROM THE "TOPOGRAPHIC SURVEY" PREPARED BY WELLSTON

ASSOCIATES LAND SURVEYORS, LLC, DATED OF SURVEY: MARCH 7, 2016.

2. THE UNDERGROUND UTILITIES SHOWN ON THIS DRAWING WERE COMPILED FROM FIELD OBSERVATIONS

WITHOUT BENEFIT OF EXCAVATION. WELLSTON ASSOCIATES LAND SURVEYORS, LLC DOES NOT

GUARANTEE THAT ALL UTILITIES ARE SHOWN. VERIFICATION OF UTILITIES SHOULD BE MADE BY THE

INDIVIDUAL UTILITY COMPANY PRIOR TO ANY CONSTRUCTION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO CONSTRUCTION. DEPTH OF

ALL EXISTING UTILITIES SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. MATERIALS

FOR ANY REQUIRED WATER OR SEWER SYSTEM RELOCATION WILL BE PROVIDED BY THE MACON WATER

AUTHORITY, BUT INSTALLATION, INCLUDING BYPASS, WILL BE INCIDENTAL TO THE CONSTRUCTION OF THE

INDIVIDUAL PROJECT. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED UTILITY RELOCATIONS.

4. CONTRACTOR WILL BE RESPONSIBLE FOR STORM WATER MANAGEMENT AND TRAFFIC CONTROL IN THE

PROJECT AREA DURING CONSTRUCTION. ALL STORMWATER SHALL BE IN ACCORDANCE WITH THE "LOCAL

STORMWATER DESIGN MANUAL FOR MACON - BIBB COUNTY, GEORGIA", LATEST EDITION. IT IS ASSUMED

THAT ALL EXISTING PIPES ARE CURRENTLY DRAINING PROPERLY. CONTRACTOR SHALL NOTIFY ENGINEER

IF EXISTING CONDITIONS DO NOT SUPPORT THIS ASSUMPTION.

5. ALL DISTURBED AREAS SHALL BE STABILIZED WITH EROSION MATTING AND PERMANENT GRASSING. ALL

SEDIMENTATION AND EROSION BMP'S SHALL BE IN ACCORDANCE WITH THE EROSION AND SEDIMENTATION

CONTROL IN GEORGIA HANDBOOK, LATEST EDITION.

6. CONTRACTOR RESPONSIBLE FOR PROVIDING CONTINUED ACCESS (ONE LANE TO REMAIN OPEN) TO

HOMEOWNERS EFFECTED BY ANY CONSTRUCTION RELATED WORK.

7. PROPOSED HEADWALLS SHALL MATCH THE DESIGN OF THE EXISTING HEADWALLS AND SHALL BE IN

ACCORDANCE WITH GDOT STANDARDS. CONTRACTOR SHALL PROVIDE PRECAST OR POUR IN PLACE

HEADWALLS AS SHOWN ON PLANS TO MATCH EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR

DETERMINING SIZE AND DESIGN OF HEADWALLS. ANY FIELD CHANGES TO HEADWALL LOCATION, DESIGN,

ETC. REQUESTED BY THE CONTRACTOR SHALL BE PRE-APPROVED BY THE ENGINEER AND AT NO

ADDITIONAL COST TO THE OWNER.

8. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS FOR ALL PRECAST OR POUR-IN-PLACE CONCRETE

STRUCTURES.

±61 LF OF 42" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 1.4%.

PROFILE VIEW - 18" DIA

SCALE: H:1"=20', V:1"=5'

±57 LF OF 18" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 2.1%.

PROPOSED HEADWALL 10-D. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 54" DIA. OPENING

PER GDOT 1001-B STANDARDS. MUST FILL IN

INVERT WITH CONCRETE APRON (TO MATCH

THICKNESS OF FOOTING)

PROPOSED HEADWALL 10-C. SHALL BE

PRE-CAST STRAIGHT WALL REINFORCED

CONCRETE HEADWALL WITH 54" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 10-A. SHALL BE

PRE-CAST L-SHAPED REINFORCED

CONCRETE HEADWALL WITH 30" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 10-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 30" DIA.

OPENING PER GDOT 1001-B STANDARDS

± 9 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

± 2 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

± 2 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

± 2 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

PROPOSED HEADWALL 10-A. SHALL BE

PRE-CAST L-SHAPED REINFORCED

CONCRETE HEADWALL WITH 30" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 10-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 30" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 10-C. SHALL BE

PRE-CAST STRAIGHT WALL REINFORCED

CONCRETE HEADWALL WITH 54" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 10-D. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 54" DIA.

OPENING PER GDOT 1001-B STANDARDS.

MUST FILL IN INVERT WITH CONCRETE

APRON (TO MATCH THICKNESS OF

FOOTING)

NOTES:

1. PLEASE REFER TO SUPPLEMENTARY DETAILS FOR HEADWALLS

PROVIDED IN ADDENDUM NO. 1.

2. HEADWALL DESIGN INFORMATION HAS BEEN UPDATED

(ADDENDUM NO. 1). ALL DIMENSIONS HAVE BEEN CONFIRMED

AND CALCULATIONS HAVE BEEN PERFORMED BY A

STRUCTURAL ENGINEER, REGISTERED IN THE STATE OF

GEORGIA. ENGINEER'S SEALS WHO APPEAR ON THIS PAGE ARE

NOT SEALING THE STRUCTURAL DESIGN OF THE HEADWALLS.

REVISED AUGUST 2, 2019: UPDATED INFO AND NOTES ON HEADWALLS (ADDENDUM NO. 1)

AutoCAD SHX Text
S
SChrabuszcz
Rectangle
SChrabuszcz
New Stamp
SChrabuszcz
New Stamp
Page 27: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

EX

IS

TIN

G 5

4"C

MP

IN

V:3

92

.7

5

EX

IS

TIN

G 5

4"C

MP

IN

V:3

93

.6

3

0+00 0+50 0+75

390

400

410

EXISTING

GROUND

ELEVATION

0+25 1+00

EXISTING

ROADWAY

APPROX. LOCATION OF

EXISTING GAS LINE

SSMH

RIM: 402.50

INV A:-9596.50

INV B:-9596.50

237

403.68

35 MPH

238

400.53

RED LIGHT

INV:393.58

24"CMP

INV:393.32

24"CMP

243

-593.19

UTP OHP OHT OHTV

244

-590.77

UTP OHP OHT OHTV

INV:399.32

24"CMP

INV:395.51

24"CMP

H

A

R

R

I

S

O

N

R

O

A

D

8

0

'

R

/

W

4

0

2

401

3

9

5

3

9

8

3

9

9

4

0

0

4

0

1

4

0

2

4

0

3

4

0

4

4

0

5

4

0

0

4

0

0

3

9

5

396

401

4

0

2

4

0

0

NOW OR FORMERLY

FRANCIS GRENIER

PARCEL L083-0153

DB 2482, PG 152

PB 831, PG 152

NOW OR FORMERLY

TR BUNTING MCWILLIAMS #658

PARCEL L083-0152

DB 627, PG 370

PB 93, PG 256

A

B

NOW OR FORMERLY

FRANCIS GRENIER

PARCEL L083-0153

DB 2482, PG 152

PB 831, PG 152

EXISTING

INV:393.63

EXISTING

INV:392.75

N

XX

X

X

3920 ARKWRIGHT RD.(478) 743-7175

DATE

SHEET OF

SCALE

PROJ. NO.

CULVERTS REPAIR / REPLACEMENT (GROUP 3)

MACON WATER AUTHORITY

FOR

JUNE 2019

5020-023-01

SUITE 101(478) 743-1703(FAX) MACON, GEORGIA 31210

BIBB COUNTY, GEORGIA

13

2018 MACON - BIBB COUNTYWIDE STORMWATER

DWG.

No. 30797PROFESSIONAL

D

A

N

I

E

L

E

.

C

H

E

E

K

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

EDIT

No. 37584PROFESSIONAL

E

R

I

C

P

I

E

RCE

J

A

C

K

S

O

N

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

MWA-2018 SW

8

1" = 20'

8-2-19

DISCLAIMER:

1. THE DESIGN / ENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED ON THE TOPOGRAPHY,

EXISTING CONDITIONS, OR DESIGNS BY OTHERS AS REFERENCED. SHOULD ANY OF THE EXISTING CONDITIONS

OR TOPOGRAPHY BE FOUND TO BE DIFFERENT OR CHANGED, THE DESIGN ENGINEER THAT PREPARED THIS

PLAN SHOULD BE CONTACTED PRIOR TO CONSTRUCTING / IMPLEMENTING THIS DESIGN, AND TO DETERMINE IF

DESIGN REVISIONS ARE REQUIRED.

2. THE ENGINEER THAT PREPARED THIS DRAWING HAS ASSUMED THAT THE CONSTRUCTION WILL BE PERFORMED

IN ACCORDANCE WITH THE ENGINEERING INTENT AND COMPLETE CONSTRUCTION SPECIFICATIONS WILL BE

PREPARED TO ACCOMPANY THE DRAWINGS. THE ENGINEER EXPECTS THAT HE WILL BE INVOLVED WITH,

PROVIDED AN OPPORTUNITY TO REVIEW, AND INSPECT PRODUCTS AND CONSTRUCTION OF THE

IMPROVEMENTS SHOWN ON THIS PLAN SHEET IN ORDER TO CONFIRM THAT THE CONSTRUCTION OF THE

IMPROVEMENTS ARE INSTALLED IN ACCORDANCE WITH DESIGN CONCEPTS. SHOULD THE DESIGN ENGINEER

NOT BE INVOLVED WITH CONSTRUCTION, HE WILL NOT BE LIABLE FOR CHANGES IN CONDITIONS OR FIELD

CONDITIONS THAT MAY AFFECT THE DESIGN.

PROJECT 11 - 5042 HARRISON ROAD

NOTES:

1. EXISTING CONDITION INFORMATION TAKEN FROM THE "TOPOGRAPHIC SURVEY" PREPARED BY WELLSTON

ASSOCIATES LAND SURVEYORS, LLC, DATED OF SURVEY: MARCH 7, 2016.

2. THE UNDERGROUND UTILITIES SHOWN ON THIS DRAWING WERE COMPILED FROM FIELD OBSERVATIONS

WITHOUT BENEFIT OF EXCAVATION. WELLSTON ASSOCIATES LAND SURVEYORS, LLC DOES NOT

GUARANTEE THAT ALL UTILITIES ARE SHOWN. VERIFICATION OF UTILITIES SHOULD BE MADE BY THE

INDIVIDUAL UTILITY COMPANY PRIOR TO ANY CONSTRUCTION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO CONSTRUCTION. DEPTH OF

ALL EXISTING UTILITIES SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. MATERIALS

FOR ANY REQUIRED WATER OR SEWER SYSTEM RELOCATION WILL BE PROVIDED BY THE MACON WATER

AUTHORITY, BUT INSTALLATION, INCLUDING BYPASS, WILL BE INCIDENTAL TO THE CONSTRUCTION OF THE

INDIVIDUAL PROJECT. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED UTILITY RELOCATIONS.

4. CONTRACTOR WILL BE RESPONSIBLE FOR STORM WATER MANAGEMENT AND TRAFFIC CONTROL IN THE

PROJECT AREA DURING CONSTRUCTION. ALL STORMWATER SHALL BE IN ACCORDANCE WITH THE "LOCAL

STORMWATER DESIGN MANUAL FOR MACON - BIBB COUNTY, GEORGIA", LATEST EDITION. IT IS ASSUMED

THAT ALL EXISTING PIPES ARE CURRENTLY DRAINING PROPERLY. CONTRACTOR SHALL NOTIFY ENGINEER

IF EXISTING CONDITIONS DO NOT SUPPORT THIS ASSUMPTION.

5. ALL DISTURBED AREAS SHALL BE STABILIZED WITH EROSION MATTING AND PERMANENT GRASSING. ALL

SEDIMENTATION AND EROSION BMP'S SHALL BE IN ACCORDANCE WITH THE EROSION AND SEDIMENTATION

CONTROL IN GEORGIA HANDBOOK, LATEST EDITION.

6. CONTRACTOR RESPONSIBLE FOR PROVIDING CONTINUED ACCESS (ONE LANE TO REMAIN OPEN) TO

HOMEOWNERS EFFECTED BY ANY CONSTRUCTION RELATED WORK.

7. PROPOSED HEADWALLS SHALL MATCH THE DESIGN OF THE EXISTING HEADWALLS AND SHALL BE IN

ACCORDANCE WITH GDOT STANDARDS. CONTRACTOR SHALL PROVIDE PRECAST OR POUR IN PLACE

HEADWALLS AS SHOWN ON PLANS TO MATCH EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR

DETERMINING SIZE AND DESIGN OF HEADWALLS. ANY FIELD CHANGES TO HEADWALL LOCATION, DESIGN,

ETC. REQUESTED BY THE CONTRACTOR SHALL BE PRE-APPROVED BY THE ENGINEER AND AT NO

ADDITIONAL COST TO THE OWNER.

8. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS FOR ALL PRECAST OR POUR-IN-PLACE CONCRETE

STRUCTURES.

PLAN VIEW

SCALE: 1"=20'

CONTRACTOR TO REMOVE

EXISTING 54" DIA. CMP

DOUBLE ROW OF SENSITIVE

SILT FENCE (TYPE-C)

(TYP.)

Sd1-S

CLASS 'A' ASPHALT

PAVEMENT REPLACEMENT

PROFILE VIEW

SCALE: H:1"=20', V:1"=5'

395

PROPERTY LINE

5' CONTOUR LINE

UTILITY POLE

GUY WIRE

SIGN

FENCE

STORM SEWER LINE

ASPHALT

P,T,TV

WATER LINE W

4031' CONTOUR LINE

OVERHEAD POWER, TELEPHONE

AND CATV

LEGEND

GRAPHIC SCALE IN FEET

0 40201020

PROPOSED PERMANENT

EASEMENT (TO BE CENTERED

ON EITHER SIDE OF PROPOSED

PIPE)

±22'

30'

90 SY OF 12" DIA.

RIP-RAP OUTLET

PROTECTION

OP

±64 LF OF 54" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 1.4%.

±30'

±64 LF OF 54" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO PROVIDE

MINIMUM SLOPE OF 1.4%.

±15 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

± 7 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

NOTES:

1. PLEASE REFER TO SUPPLEMENTARY DETAILS FOR HEADWALLS

PROVIDED IN ADDENDUM NO. 1.

2. HEADWALL DESIGN INFORMATION HAS BEEN UPDATED

(ADDENDUM NO. 1). ALL DIMENSIONS HAVE BEEN CONFIRMED

AND CALCULATIONS HAVE BEEN PERFORMED BY A

STRUCTURAL ENGINEER, REGISTERED IN THE STATE OF

GEORGIA. ENGINEER'S SEALS WHO APPEAR ON THIS PAGE ARE

NOT SEALING THE STRUCTURAL DESIGN OF THE HEADWALLS.

PROPOSED HEADWALL 11-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 66" DIA.

OPENING PER GDOT 1001-B STANDARDS.

MUST FILL IN INVERT WITH CONCRETE

APRON (TO MATCH THICKNESS OF

FOOTING)

REVISED AUGUST 2, 2019: UPDATED INFO AND NOTES ON HEADWALLS (ADDENDUM NO. 1)

PROPOSED HEADWALL 11-A. SHALL BE

PRE-CAST STRAIGHT WALL REINFORCED

CONCRETE HEADWALL WITH 66" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 11-A. SHALL BE

PRE-CAST STRAIGHT WALL REINFORCED

CONCRETE HEADWALL WITH 66" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 11-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 66" DIA.

OPENING PER GDOT 1001-B STANDARDS.

MUST FILL IN INVERT WITH CONCRETE

APRON (TO MATCH THICKNESS OF

FOOTING)

SChrabuszcz
Rectangle
SChrabuszcz
New Stamp
SChrabuszcz
New Stamp
Page 28: ADDENDUM NO. 1 DATE: August 2, 2019 SPECIFICATIONS AND

EX

IS

TIN

G 48"C

MP

IN

V:450.59

EX

IS

TIN

G 48"C

MP

IN

V:450.53

0+00 0+50 0+75

450

460

EXISTING

GROUND

ELEVATION

0+25

470

EXISTING

ROADWAY

APPROX. LOCATION

OF EXISTING WATER

LINE

1+00

EXISTING UNDERGROUND

UTILITIES (TYP.)

249

460.76

SSMH

4

5

7

4

5

6

4

5

5

4

5

4

4

5

3

452

4

5

3

4

5

4

4

5

5

459

460

460

4

5

5

4

5

4

4

5

3

4

5

2

4

5

1

4

5

0

4

5

2

4

5

1

4

6

1

NOW OR FORMERLY

INNOVATIVE FIBER TECH, LLC

PARCEL K008-0241

DB 8003, PG 275

PB 92, PG 839

NOW OR FORMERLY

MIDDLE FORK, LLC

PARCEL K008-0162

DB 4207, PG 259

PB 88, PG 399

NOW OR FORMERLY

ISPW ASSOCIATES

PARCEL K008-00010

DB 7724, PG 226

N

EXISTING

INV:450.53

CA

VA

LIE

R D

RIV

E (80'R

/W

)

XX

XX

EXISTING

INV:450.59

3920 ARKWRIGHT RD.(478) 743-7175

DATE

SHEET OF

SCALE

PROJ. NO.

CULVERTS REPAIR / REPLACEMENT (GROUP 3)

MACON WATER AUTHORITY

FOR

JUNE 2019

5020-023-01

SUITE 101(478) 743-1703(FAX) MACON, GEORGIA 31210

BIBB COUNTY, GEORGIA

13

2018 MACON - BIBB COUNTYWIDE STORMWATER

DWG.

No. 30797PROFESSIONAL

D

A

N

I

E

L

E

.

C

H

E

E

K

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

EDIT

No. 37584PROFESSIONAL

E

R

I

C

P

I

E

RCE

J

A

C

K

S

O

N

E

N

G

IN

E

E

R

R

E

G

I

ST

E

R

E

D

G

E

O

RG

I

A

.

MWA-2018 SW

9

1" = 20'

8-2-19

DISCLAIMER:

1. THE DESIGN / ENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED ON THE TOPOGRAPHY,

EXISTING CONDITIONS, OR DESIGNS BY OTHERS AS REFERENCED. SHOULD ANY OF THE EXISTING CONDITIONS

OR TOPOGRAPHY BE FOUND TO BE DIFFERENT OR CHANGED, THE DESIGN ENGINEER THAT PREPARED THIS

PLAN SHOULD BE CONTACTED PRIOR TO CONSTRUCTING / IMPLEMENTING THIS DESIGN, AND TO DETERMINE IF

DESIGN REVISIONS ARE REQUIRED.

2. THE ENGINEER THAT PREPARED THIS DRAWING HAS ASSUMED THAT THE CONSTRUCTION WILL BE PERFORMED

IN ACCORDANCE WITH THE ENGINEERING INTENT AND COMPLETE CONSTRUCTION SPECIFICATIONS WILL BE

PREPARED TO ACCOMPANY THE DRAWINGS. THE ENGINEER EXPECTS THAT HE WILL BE INVOLVED WITH,

PROVIDED AN OPPORTUNITY TO REVIEW, AND INSPECT PRODUCTS AND CONSTRUCTION OF THE

IMPROVEMENTS SHOWN ON THIS PLAN SHEET IN ORDER TO CONFIRM THAT THE CONSTRUCTION OF THE

IMPROVEMENTS ARE INSTALLED IN ACCORDANCE WITH DESIGN CONCEPTS. SHOULD THE DESIGN ENGINEER

NOT BE INVOLVED WITH CONSTRUCTION, HE WILL NOT BE LIABLE FOR CHANGES IN CONDITIONS OR FIELD

CONDITIONS THAT MAY AFFECT THE DESIGN.

PROJECT 12 - 4269 CAVALIER DRIVE

NOTES:

1. EXISTING CONDITION INFORMATION TAKEN FROM THE "TOPOGRAPHIC SURVEY" PREPARED BY WELLSTON

ASSOCIATES LAND SURVEYORS, LLC, DATED OF SURVEY: MARCH 7, 2016.

2. THE UNDERGROUND UTILITIES SHOWN ON THIS DRAWING WERE COMPILED FROM FIELD OBSERVATIONS

WITHOUT BENEFIT OF EXCAVATION. WELLSTON ASSOCIATES LAND SURVEYORS, LLC DOES NOT

GUARANTEE THAT ALL UTILITIES ARE SHOWN. VERIFICATION OF UTILITIES SHOULD BE MADE BY THE

INDIVIDUAL UTILITY COMPANY PRIOR TO ANY CONSTRUCTION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO CONSTRUCTION. DEPTH OF

ALL EXISTING UTILITIES SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. MATERIALS

FOR ANY REQUIRED WATER OR SEWER SYSTEM RELOCATION WILL BE PROVIDED BY THE MACON WATER

AUTHORITY, BUT INSTALLATION, INCLUDING BYPASS, WILL BE INCIDENTAL TO THE CONSTRUCTION OF THE

INDIVIDUAL PROJECT. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED UTILITY RELOCATIONS.

4. CONTRACTOR WILL BE RESPONSIBLE FOR STORM WATER MANAGEMENT AND TRAFFIC CONTROL IN THE

PROJECT AREA DURING CONSTRUCTION. ALL STORMWATER SHALL BE IN ACCORDANCE WITH THE "LOCAL

STORMWATER DESIGN MANUAL FOR MACON - BIBB COUNTY, GEORGIA", LATEST EDITION. IT IS ASSUMED

THAT ALL EXISTING PIPES ARE CURRENTLY DRAINING PROPERLY. CONTRACTOR SHALL NOTIFY ENGINEER

IF EXISTING CONDITIONS DO NOT SUPPORT THIS ASSUMPTION.

5. ALL DISTURBED AREAS SHALL BE STABILIZED WITH EROSION MATTING AND PERMANENT GRASSING. ALL

SEDIMENTATION AND EROSION BMP'S SHALL BE IN ACCORDANCE WITH THE EROSION AND SEDIMENTATION

CONTROL IN GEORGIA HANDBOOK, LATEST EDITION.

6. CONTRACTOR RESPONSIBLE FOR PROVIDING CONTINUED ACCESS (ONE LANE TO REMAIN OPEN) TO

HOMEOWNERS EFFECTED BY ANY CONSTRUCTION RELATED WORK.

7. PROPOSED HEADWALLS SHALL MATCH THE DESIGN OF THE EXISTING HEADWALLS AND SHALL BE IN

ACCORDANCE WITH GDOT STANDARDS. CONTRACTOR SHALL PROVIDE PRECAST OR POUR IN PLACE

HEADWALLS AS SHOWN ON PLANS TO MATCH EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR

DETERMINING SIZE AND DESIGN OF HEADWALLS. ANY FIELD CHANGES TO HEADWALL LOCATION, DESIGN,

ETC. REQUESTED BY THE CONTRACTOR SHALL BE PRE-APPROVED BY THE ENGINEER AND AT NO

ADDITIONAL COST TO THE OWNER.

8. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS FOR ALL PRECAST OR POUR-IN-PLACE CONCRETE

STRUCTURES.

PLAN VIEW

SCALE: 1"=20'

CONTRACTOR TO REMOVE

EXISTING 48" DIA. CMP

DOUBLE ROW OF SENSITIVE

SILT FENCE (TYPE-C)

(TYP.)

Sd1-S

CLASS 'A' ASPHALT

PAVEMENT REPLACEMENT

PROFILE VIEW

SCALE: H:1"=20', V:1"=5'

LEGEND

GRAPHIC SCALE IN FEET

0 40201020

403

PROPERTY LINE

1' CONTOUR LINE

STORM SEWER LINE

OVERHEAD POWER, TELEPHONE

AND CATV

ASPHALT

P,T,TV

WATER LINE W

UNDERGROUND TELEPHONE UT

SANITARY SEWER LINE SAN

EASEMENT LINE

5' CONTOUR LINE 395

±61 LF OF 48" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO MATCH

EXISTING CONDITIONS.

10'

±23'

PROPOSED TEMPORARY

CONSTRUCTION EASEMENT

(TO BE CENTERED ON EITHER

SIDE OF PROPOSED PIPE)

10'

30'

PROPOSED TEMPORARY

CONSTRUCTION EASEMENT

(TO BE CENTERED ON EITHER

SIDE OF PROPOSED PIPE)

70 SY OF 12" DIA. RIP-RAP

OUTLET PROTECTION

OP

±61 LF OF 48" DIA. CLASS III REINFORCED

CONCRETE PIPE. CONTRACTOR TO FIELD

CONFIRM AND SET GRADE TO MATCH

EXISTING CONDITIONS.

PROPOSED HEADWALL 12-A. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 60" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 12-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 60" DIA.

OPENING PER GDOT 1001-B STANDARDS

± 7 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

± 8 CY OF COMPACTED BACKFILL

BEHIND HEADWALL TO PROMOTE

DRAINAGE AND PREVENT EROSION

AND UNDERMINING OF HEADWALL

PROPOSED HEADWALL 12-A. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 60" DIA.

OPENING PER GDOT 1001-B STANDARDS

PROPOSED HEADWALL 12-B. SHALL BE

PRE-CAST 45° WINGWALL REINFORCED

CONCRETE HEADWALL WITH 60" DIA.

OPENING PER GDOT 1001-B STANDARDS

NOTES:

1. PLEASE REFER TO SUPPLEMENTARY DETAILS FOR HEADWALLS

PROVIDED IN ADDENDUM NO. 1.

2. HEADWALL DESIGN INFORMATION HAS BEEN UPDATED

(ADDENDUM NO. 1). ALL DIMENSIONS HAVE BEEN CONFIRMED

AND CALCULATIONS HAVE BEEN PERFORMED BY A

STRUCTURAL ENGINEER, REGISTERED IN THE STATE OF

GEORGIA. ENGINEER'S SEALS WHO APPEAR ON THIS PAGE ARE

NOT SEALING THE STRUCTURAL DESIGN OF THE HEADWALLS.

REVISED AUGUST 2, 2019: UPDATED INFO AND NOTES ON HEADWALLS (ADDENDUM NO. 1)

SChrabuszcz
Rectangle
SChrabuszcz
New Stamp
SChrabuszcz
New Stamp