Purchasing Services Post Office Box 2570
Waco, Texas 76702-2570 Phone: 254 / 750-8405
Fax: 254 / 750-8063 [email protected]
CITY OF WACO www.waco-texas.com
Date: 10/4/2018 RFP No: 2018-053 Commodity: Cameron Park Zoo Entrance Modifications Buyer: Kasey Gamblin
Closing Time: Part A, 2:00 P.M. CST, October 11, 2018 Closing Time: Part B, 2:00 P.M. CST, October 12, 2018
Opening Time: Part A & B, 2:01 P.M. CST, October 12, 2018
Proposal Opening Location: Operations Center, Purchasing Services Office, 1415 N. 4th St., Waco, TX 76707
______________________________________________________ Addendum No: 1
The above-mentioned Proposal invitation has been changed in the following manner. Sign and return addendum to the Purchasing Office by the closing time and date with your RFP response. Returning this page signed by your authorized agent will serve to acknowledge this change. All other requirements of the invitation remain unchanged. If you have any questions, please call or stop by the Purchasing Office at the above address.
Additional Drawings S1.0, S2.0 and S3.0
PLEASE SEE THE FOLLOWING PAGES BELOW
Firm:_____________________________________________________________________________________ Address___________________________________________________________________________________ Signature of Person Authorized to Sign Proposal:______________________________________________________________________ Signor's Name and Title (print or type):_____________________________________________________________________________ E-mail Address:____________________________________________________________________________ Date:____________________Telephone:___________________________Fax:_________________________
RFP 2018-053 Cameron Park Zoo Entrance Modifications
1 of 5
Page 1 of 1
Project: Entry Building Renovations RA# 1801 Owner: Cameron Park Zoo, City of Waco 1701 N 4th St Waco, TX 76707 Architect: Reliance Architecture, LLC 1306 Barrington Dr. Austin, TX 78753 Date of Issuance: October 3, 2018 Addendum to the Drawings and Project Manual dated April 16, 2018.
The Contract Documents previously issued for bidding, as referenced above, shall be amended, revised, supplemented, clarified and/or extended by the following information, and this information shall be considered to be a part of the Drawings and Project Manual, as thought it had been issued at the same time and incorporated integrally with such Drawings and Project Manual. Where provisions of the following information differ from those of the original Contract Documents, this addendum shall govern and take precedence. The drawings for the work within this Project shall be designated with letters as follows: A – Architectural; C – Civil; QF – Food Service; TE – Theatrical; S – Structural; T – Technology; M – Mechanical; P – Plumbing; E - Electrical Example: AR.1, Architectural Revision Sheet Number 1 This shall be used whenever referring to the work for this project.
Item 1. S1.0 - PROJECT VIEW & GENERAL NOTES
A. Add this sheet and include in its entirety to the contract documents. Item 2. S2.0 - SECOND FLOOR & ROOF FRAMING PLANS
A. Add this sheet and include in its entirety to the contract documents. ITEM 3. S3.0 - FRAMING DETAILS
A. Add this sheet and include in its entirety to the contract documents.
S1.0 S2.0 S3.0
October 3, 2018
August 21, 2018.
RFP 2018-053 Cameron Park Zoo Entrance Modifications
2 of 5
USE AND/OR RELEASE OF STRUCTURAL ENGINEERING ELECTRONIC FILE.THE ELECTRONIC FILES FOR THE STRUCTURAL ENGINEERING DOCUMENTS WILL NOT BE RELEASED FOR USE DURING CONSTRUCTION OR FOR THE PREPARATION OF SHOP DRAWINGS OR SUBMITTALS. EACH SUPPLIER OR FABRICATOR IS RESPONSIBLE FOR REPRODUCING THE INFORMATION REQUIRED FOR THEIR SUBMITTAL. THE DUPLICATING OF ANY PART OF THESE DOCUMENTS FOR INCLUSION IN SHOP DRAWINGS OR SUBMITTALS IS ALSO PROHIBITED
STRUCTURAL REQUIREMENTS FOR SUBMITTALSTHE FOLLOWING ARE SUBMITTALS REQUIRED BY ENGINEER. USE PLANS AND SPEC BOOK FOR PRODUCT LIST.
1. ANCHOR BOLTS. 2 STRUCTURAL STEEL
STRUCTURAL STEEL1. STRUCTURAL STEEL DESIGN AND CONSTRUCTION SHALL CONFORM TO IBC CHAPTER 22, - GENERAL DESIGN REQUIREMENTS, ALL STEEL SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST AISC SPECIFICATIONS FOR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS.2. ALL WELDING SHALL BE IN ACCORDANCE WITH THE LATEST AMERICAN WELDING SOCIETY SPECIFICATIONS. 3. ALL STRUCTURAL STEEL SHALL BE ASTM A992.4. ALL BOLTS SHALL BE ASTM A307.5. ALL STEEL TO BE GIVEN ONE SHOP COAT OF RUST INHIBITIVE PRIMER, AFTER FABRICATION.6. STRUCTURAL STEEL SUPPLIER IS RESPONSIBLE FOR & SHALL SUBMIT SHOP DRAWINGS FOR ALL STRUCTURAL STEEL.7. STRUCTURAL STEEL SUPPLIER SHALL FURNISH BOLTS FOR OSHA CONNECTIONS (SEE DRAWINGS FOR DETAILS).8. PROVIDE PROTECTIVE ASPHALTIC COATING OR EQUAL AROUND STRUCTURAL STEEL BELOW GRADE.
STEEL MATERIAL PROPERTIES1. STEEL PROPERTIES : FY,PSI ASTM
A. STRUCTURAL WIDE FLANGE SHAPES . . . . . 50,000 A992B. OTHER STRUCT. SHAPES, ETC. . . . . . . . . 36,000 A36C. HIGH STRENGTH BOLTS, U.N.O. . . . . . . . . 74,000 A325D. ANCHOR BOLTS (TENSILE STRENGTH) . . . . 60,000 A307E. WELDING ELECTRODES . . . . . . . . . . . . . E70XX A233F. DECK WELDING ELECTRODES . . . . . . . . E60XX A233G. STRUCTURAL PIPES . . . . . . . . . . . . . . . . 36,000 A53, GRADE BH. STRUCTURAL TUBES . . . . . . . . . . . . . . . . 46,000 A500, GRADE BI. HEADED STUDS . . . . . . . . . . . . . . . . . 50,000 A108
STRUCTURAL REQUIREMENTS FOR SITE VISITS.SITE VISITS FOR CONSTRUCTION OBSERVATION WILL NOT BE MADE BY ENGINEER UNTIL ALL SUBMITTALS AND OR TESTING RESULTS HAVE BEEN REVIEWED AND ACCEPTED BY THE ENGINEER. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING SUBMITTALS TO ALLOW THE ENGINEER ADEQUATE TIME TO REVIEW AND COMMENT BEFORE PROCEEDING WITH CONSTRUCTION.
REPRESENTATIVE OF KINGSSE WILL VISIT THE SITE AT THE FOLLOWING STAGES OF CONSTRUCTION:
A. AFTER STEEL IS ERECTED BUT PRIOR TO COVERING WITH OTHER MATERIALS.
PLEASE REFER TO SPECIFICATIONS OR GENERAL NOTES FOR PROJECT SPECIFIC INSTRUCTIONS.
CONTRACTOR SHALL ISSUE TO THE ENGINEER A COMPLETE PROJECT SCHEDULE WITH THE ABOVE SITE VISIT NOTED AND NOTIFY THE ENGINEER A MINIMUM OF 48 HOURS PRIOR TO THE SCHEDULED VISIT TO CONFIRM TIME AND DATE OF REQUIRED VISIT. FAILURE OF THE CONTRACTOR TO ACCOMPLISH THIS NOTIFICATION WILL NOT REQUIRE THE ENGINEER TO RESPOND ON SHORTER NOTICE, NOR WILL THE CONTRACTOR PROCEED WITHOUT THE ENGINEER PERFORMING APPROPRIATE SITE VISIT. ADDITIONALLY IF THE CONTRACTOR REQUESTS OR SCHEDULES A SITE VISIT AND CONSTRUCTION IS NOT AT THE APPROPRIATE STAGE FOR THE ENGINEER TO PERFORM THE PROPER OBSERVATIONS, ANOTHER SITE VISIT WILL BE REQUIRED AND SCHEDULED AT THE CONTRACTOR EXPENSE FOR ALL TIME AND TRAVEL EXPENSES OF THE ENGINEER OR HIS REPRESENTATIVE. ENGINEER WILL NOT ISSUE ANY TYPE OR FORM OF COMPLIANCE OR CONCURRENCE STATEMENT FOR CONSTRUCTION WITHOUT PERFORMING THE ABOVE NOTED SITE OBSERVATIONS.
DESIGN DATA
A. BUILDING CODE1. INTERNATIONAL BUILDING CODE 2015 EDITION WITH CITY OF WACO AMENDMENTS.
B. DESIGN LOADS
1. WIND LOAD EXPOSURE BDESIGN WIND SPEED 115 MPH
2. ROOF LOADS LIVE LOAD (L.L.) 20 PSF**DEAD LOAD (DESIGN) (D.L.) 20 PSF
3. SEISMIC ZONE 0 * REDUCED PER I.B.C. SEC. 1607.9 ** REDUCED PER I.B.C. SEC. 1605.3
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL COORDINATE ALL STRUCTURAL PLANS AND DETAILS WITH THE ARCHITECT BEFORE STARTING WORK. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.
THE STRUCTURAL SYSTEMS OF THE FLOOR AND ROOF ARE DESIGNED TO PERFORM AS A COMPLETE UNIT. DURING DEMOLITION AND REPAIR OF THESE STRUCTURES, STRUCTURAL COMPONENTS MAY BE UNSTABLE AND IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE TEMPORARY SHORING AND/OR BRACING AS REQUIRED FOR THE STABILITY OF THE INCOMPLETE STRUCTURE AND FOR THE SAFETY OF ALL ON-SITE PERSONNEL.
C. ALTERNATE DESIGNSALTERNATE STRUCTURAL SYSTEMS & DETAILS WILL ONLY BE CONSIDERED PROVIDED THEY ARE SUBMITTED WITH CALCULATIONS CERTIFIED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT. THE CALCULATIONS MUST SHOW THE EQUIVALENCY OF THE ALTERNATE & ACCEPTANCE OF THE ALTERNATE BY THE ENGINEER MUST BE IN WRITING.
D. FUTURE EXPANSION THIS PROJECT IS NOT DESIGNED FOR FUTURE EXPANSION.
E. ROOF SLOPE THE ROOF HAS NOT BEEN DESIGNED FOR PONDING BASED ON A ROOF SLOPE OF 8" PER FOOT.
F. CONTRACTOR TO VERIFY ALL CONDITIONS AT THE JOBSITE AND REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO START OF ANY CONSTRUCTION.
WOOD FRAMING:1. ALL BOLTS SHALL BE ASTM A-307. 2. ALL BEAM FRAMING LUMBER SHALL BE NO.1 GRADE SOUTHERN PINE KILN-DRIED OR BETTER. ALL COLUMN LUMBER SHALL BE NO. 1 DOUGLAS FIR KILN- DRIED OR BETTER. 3. ALL WOOD CONNECTOR AND HANGERS SHALL BE AS MANUFACTURED BY SIMPSON STRONG-TIE CO. OR EQUAL. 4. ALL CONNECTORS OR HANGERS FOR PRESSURE TREATED MATERIAL SHALL BE STAINLESS STEEL. 5. ALL WOOD FRAMING SHALL BE #2 SOUTHERN YELLOW PINE OR BETTER.
DETAILS NOTESDETAILS NOTED AS TYPICAL SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE.
I.
II
III
IV.
V.
VI.
VII.
STRUCTURAL NOTES DRAWING SYMBOLS
ABBREVIATIONS
DRAWING INDEX
AA.B. ANCHOR BOLTALT. ALTERNATEARCH. ARCHITECT(URAL)
BB.S. BOTH SIDESBBE. BOTTOM BEAM ELEVATIONBLKG. BLOCKINGBLDG. BUILDINGBM. BEAMBOT. BOTTOMBRG. BEARINGBSMT. BASEMENTBTWN. BETWEENBLK BLOCK
CC.J. CONTROL JOINTCL CENTER LINECLR. CLEAR(ANCE)C.M.U. CONCRETE MASONRY UNITC.B. CONCRETE BLOCKCOL. COLUMNCONC. CONCRETECONN. CONNECTIONCONST. CONSTRUCTIONCONT. CONTINUOUSC.I.P. CAST IN PLACECOMP COMPOSITE
DDET. DETAILDIA. DIAMETERDIAG. DIAGONALDN. DOWNDWG. DRAWINGDBL. DOUBLED.L. DEAD LOADDO DITTO
EE EASTEA. EACHE.S. EACH SIDEELEV. ELEVATIONEQ. EQUALEXIST. EXISTINGEXP. EXPANSIONEXT. EXTERIOR
FFD. FLOOR DRAINFDN. FOUNDATIONFTG. FOOTINGFUT. FUTUREF.S. FAR SIDEFAB. FABRICATE(OR)FLG. FLANGEF.O.B. FACE OF BRICK
GGA. GAGE, GAUGEGALV. GALVANIZEDG.C. GENERAL CONTRACTORG.B. GRADE BEAM
HH.C.A HEADED CONCRETE ANCHORHORIZ. HORIZONTALHT. HEIGHTH.S. HEADED STUDSHSS TUBE STEEL
IINFO. INFORMATIONI.F. INSIDE FACE
JJST. JOISTJT. JOINTJ/BRG JOIST BEARING
KK KIPK.B. KNEE BRACEK.O. KNOCK-OUTK.S.I. KIPS PER SQ. INCH
LLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALL.L. LIVE LOAD
MMIN. MINIMUMMAS. MASONRYMAX. MAXIMUMMANUF. MANUFACTURERMEZZ. MEZZANINEMISC. MISCELLANEOUSM.O. MASONRY OPENINGMATL. MATERIALMTL. METAL
NN NORTHNTS NOT TO SCALEN.S. NEAR SIDEN.I.C. NOT IN CONTRACT
OO.C. ON CENTER(S)O.S. OUTSIDEOPNG. OPENINGOPP. OPPOSITEO.F. OUTSIDE FACE
PP.C. PRECAST CONCRETEPERIM. PERIMETERP.J. PANEL JOINTPL PLATEPLF POUNDS PER LINEAR FOOTPMB PRE-ENGINEERED METAL BUILDINGPROJ. PROJECTIONPSF. POUNDS PER SQ. FOOTPSI. POUNDS PER SQ. INCHP T PRESSURE TREATED
QQTY. QUANTITY
RRAD. RADIUSR.D. ROOF DRAINREV. REVISION, REVISE(D)REINF. REINFORCE(D), (ING)REF. REFERENCEREQ'D. REQUIRED
SS SOUTHSCHED. SCHEDULESIM. SIMILARSQ. SQUARESTD. STANDARDSTL. STEELSTRUCT STRUCTURALSPA. SPACE(S)S.L. SNOW LOAD
TTEMP. TEMPORARYTYP. TYPICALT.O. TOP OFTBE. TOP OF BEAM ELEVATIONTDE. TOP OF DECK ELEVAIONTFE. TOP OF FOOTING ELEVATIONTSE. TOP OF SLAB ELEVATIONT&B TOP AND BOTTOMT&G TONGUE AND GROOVE
UUNEXC. UNEXCAVATEDU.N.O. UNLESS NOTED OTHERWISE
VVERT. VERTICAL
WW WESTW/ WITHW.P. WORK POINTW.W.F. WELDED WIRE FABRIC
EARTH/COMPACT FILL
WOOD BLOCKING
WELDED WIRE FABRIC
SPAN DIRECTION OFHOLLOW CORE SLABS
BEAM SPLICE LOCATIONS
BEAM MOMENT CONNECTIONM
MASONRY WALL
COLUMN GRID LINE & GRID DESIGNATIONSGRID DESIGNATION
SECTION CUTS
DETAIL TARGETSDETAIL NUMBERSHEET NUMBER
SECTION NUMBERSHEET NUMBER
REVISED AREA CLOUDEDREVISION NUMBER
0
0A
1A101 S1.0
SHEET NUMBERSECTION NUMBER
1
A101
ELEVATION TARGET S1.0
1A101 S1.0
REVISION CLOUDS
1
OF
TEXAS
ER
ENSED
AL
ENGIN
E
ETA T S
CIL
OISSEFORPPATRICK ASIEDU
105858
N
THE
SEAL
APP
EARI
NG O
N TH
IS D
OCU
MEN
T W
ASAU
THO
RIZE
D BY
PAT
RICK
ASI
EDU,
P.E
. 10
5858
.TH
IS D
RAW
ING
IS IS
SUED
FO
R CO
NSTR
UCTI
ON.
THIS
DRA
WIN
G M
AY N
OT
BE M
ODI
FIED
WIT
HOUT
THE
EXPR
ESS
WRI
TTEN
CO
NSEN
T O
F TH
EEN
GIN
EER,
AND
THE
N O
NLY
IN A
CCO
RDAN
CEW
ITH
THE
RULE
S O
F TH
E TE
XAS
ENG
INEE
RING
PRAC
TICE
ACT
.
KINGSSEProject No.
Date
Drawn by Checked by
REVI
SIO
NSKI
NGS
STRU
ARCH
URAL
, INC
.
2851
, Joe
DiM
aggi
o, U
nit 2
2 Ro
und
Rock
, Tex
as 7
8665
Phon
e (5
12) 2
71-7
331
TBPE
Reg
istr
atio
n No
. F-1
3346
Sheet Name:
Sheet No.
Phase:100% CD
04/16/
18
AM PA
KIN
GS
SE
4/12
/201
8 6:
57:0
4 PM
\\Se
rver
2012
\Com
pany
\PRO
JECT
S-18
0000
\180
214
- Cam
eron
Par
k Zo
o En
try
Reno
vatio
n\Dr
awin
gs\1
8021
4 - C
amer
on P
ark
Zoo
Entr
y Re
nova
tion_
Str_
R17.
rvt
S1.0
PROJECT VIEW & GENERALNOTES
180214
CAM
ERO
N PA
RK Z
OO
ENT
RY R
ENO
VATI
ON
04/16/18
WAC
O /
MCL
ENN
AN C
OUN
TY,
TEXA
S
S1.0 PROJECT VIEW & GENERAL NOTESS2.0 SECOND FLOOR & ROOF FRAMING PLANSS3.0 FRAMING DETAILS
No
.D
escri
pti
on
Date
RFP 2018-053 Cameron Park Zoo Entrance Modifications
3 of 5
A
B
2 3 4 5 6 71 8
47' - 5"
7' - 3" 4' - 11" 8' - 1" 6' - 11" 8' - 1" 4' - 11" 7' - 3"
10' -
9"
2S3.0
TYP.
NEW HSS 3x3x1/4 COLUMNCONNECTED TO EXISTINGCOLUMN IN RAILING(TYP U N O )
EXISTING RAILING
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
2L3X
3X1/
4
3 1/2"3 1/2"
1' - 6
"1'
- 6"
1S3.0
A
B
2 3 4 5 6 71 8
47' - 5"
7' - 3" 4' - 11" 8' - 1" 6' - 11" 8' - 1" 4' - 11" 7' - 3"
10' -
9"
HSS3X3X1/4
5' -
4 1/
2"5'
- 4
1/2"
13' -
9"
48' - 0"
6S3.0
6S3.0
3S3.0
TYP.
4S3.0
K.B.
K.B.
K.B.
K.B.
9S3.0
8S3.0
8S3.0
HSS3x3x3/16 RIDGE BEAM, TYP.
HSS3X3X1/4 HSS3X3X1/4HSS3X3X1/4 HSS3X3X1/4 HSS3X3X1/4 HSS3X3X1/4
HSS3X3X1/4 HSS3X3X1/4 HSS3X3X1/4 HSS3X3X1/4 HSS3X3X1/4 HSS3X3X1/4 HSS3X3X1/4
HSS3X3X1/4STUB COL.
HSS3X3X1/4STUB COL.
HSS3X3X1/4STUB COL.
HSS3X3X1/4STUB COL.
OF
TEXAS
ER
ENSED
AL
ENGIN
E
ETA T S
CIL
OISSEFORPPATRICK ASIEDU
105858
N
THE
SEAL
APP
EARI
NG O
N TH
IS D
OCU
MEN
T W
ASAU
THO
RIZE
D BY
PAT
RICK
ASI
EDU,
P.E
. 10
5858
.TH
IS D
RAW
ING
IS IS
SUED
FO
R CO
NSTR
UCTI
ON.
THIS
DRA
WIN
G M
AY N
OT
BE M
ODI
FIED
WIT
HOUT
THE
EXPR
ESS
WRI
TTEN
CO
NSEN
T O
F TH
EEN
GIN
EER,
AND
THE
N O
NLY
IN A
CCO
RDAN
CEW
ITH
THE
RULE
S O
F TH
E TE
XAS
ENG
INEE
RING
PRAC
TICE
ACT
.
KINGSSEProject No.
Date
Drawn by Checked by
REVI
SIO
NSKI
NGS
STRU
ARCH
URAL
, INC
.
2851
, Joe
DiM
aggi
o, U
nit 2
2 Ro
und
Rock
, Tex
as 7
8665
Phon
e (5
12) 2
71-7
331
TBPE
Reg
istr
atio
n No
. F-1
3346
Sheet Name:
Sheet No.
Phase:100% CD
04/16/
18
AM PA
KIN
GS
SE
4/12
/201
8 6:
57:0
4 PM
\\Se
rver
2012
\Com
pany
\PRO
JECT
S-18
0000
\180
214
- Cam
eron
Par
k Zo
o En
try
Reno
vatio
n\Dr
awin
gs\1
8021
4 - C
amer
on P
ark
Zoo
Entr
y Re
nova
tion_
Str_
R17.
rvt
S2.0
SECOND FLOOR & ROOFFRAMING PLANS
180214
CAM
ERO
N PA
RK Z
OO
ENT
RY R
ENO
VATI
ON
04/16/18
WAC
O /
MCL
ENN
AN C
OUN
TY,
TEXA
S
1/4" = 1'-0"1
2nd Floor Framing Plan
1/4" = 1'-0"2
Roof Framing Plan
No
.D
escri
pti
on
Date
RFP 2018-053 Cameron Park Zoo Entrance Modifications
4 of 5
HS
S3X
3X
1/4
2L3X3X1/4
HS
S3X
3X
1/4
2L3X3X1/4
S3.0
2
STANDING SEAM METAL ROOF DECK
S3.0
3
S3.0
4
S3.0
5
AB
T.O.S. = 20' 10 1/2"
T.O.EXIST. COL. = 16'-6"
T.O.S. = 24'-6"
T.O.S. = 22'-8 1/2"
REF. PLAN
PLAN
REF.
F.F.E. = 0'-0"
EXIST. COL.
PL3/8" x
TYP.
5 1/
2"
EXIST. COL.
COL. REF. PLAN
CUT EXIST. CAP PL AND INSTALL HSS2 1/2x2 1/2x 3/16 x 1'-0" SLEEVE
TYP.
MIN6"
COLUMN W/ 1/4" CAP PL. (REF. PLAN)
BEAM REF. PLAN
RAFTER REF. PLAN
STANDING SEAMMETAL ROOF DECK(REF. ARCH.)
2x NAILER W/ 3/8"Ø BOLTS @ 12" O.C.
REF. PLAN
3/16
3/16
PL1/4 @ 16" O.C.
PLAN VIEW
RIDGE TIE BEAM REF. PLAN
T & G DECKING REF.ARCH.
RIDGE TIE BEAM REF. PLAN
RAFTER REF. PLAN3/16
TYP.
2x NAILER W/ 3/8"Ø BOLTS @ 12" O.C.
STANDING SEAMMETAL ROOF DECK
RIDGE CAP REF. ARCH.
3/8" GUSSET PL
3/16
RAFTER REF. PLAN
1/4" SPACER PL.@ 16" O.C.
3/16
RAFTER REF. PLAN
STANDING SEAMMETAL ROOF DECK
3/8" x 4"
2x NAILER W/ 3/8"Ø BOLTS @ 12" O.C.
3/16
COL. REF. PLAN
BEAM REF. PLAN
RAFTER REF. PLAN
STANDING SEAMMETAL ROOF DECK
2x NAILER W/ 3/8"Ø BOLTS @ 12" O.C.
A
FLASHING BYOTHERS
1/8
CAP PL1/4x3 1/2" x 0'-
3/16TYP.
3/16TYP.
1' - 3
1/2"
BEAM REF. PLAN
RAFTER REF. PLAN
STANDING SEAMMETAL ROOF DECK
2x NAILER W/ 3/8"Ø BOLTS @ 12" O.C.
REF. PLAN
HSS3x3x1/4 x 0'-5 1/2"STUB COLUMN W/ 1/4"CAP PL.
3/16
3/16
EXIST. BRICK VENNER
BEAM REF. PLAN
RAFTER REF. PLAN
T.O.S. = 24'-6"
FLASHING BY OTHERS
RIDGE CAP REF. ARCH.
5"
3/16
1/4" SPACER PL@ 16"O.C. TYP.
4S3.0
SIM.
T.O.S. = 20'-10 1/2"
HSS3x3x1/4 x 0'-5 1/2"STUB COL.
3/16
BEAM REF. PLAN
COL. REF. PLAN
PL1/4 E.S. TYP.
EXIST. WALKWAY RAILING CAP STONE
T.O.S. = 20'-10 1/2"
3/16E.S. TYP.
3/16E.S. TYP.
1' - 11 1/4"
TYP. U
.N.O
.
2' - 5 1/2"
3/8" PL SPACER, TYP.
1' - 3"
3' - 0 1/2"
TEXAS STAR; MATCH EXIST.AT TICKET BOOTH BELOW
3/16TYP.
4' - 7 1/2"
3' -
5 1/
2"
OF
TEXAS
ER
ENSED
AL
ENGIN
E
ETA T S
CIL
OISSEFORPPATRICK ASIEDU
105858
N
THE
SEAL
APP
EARI
NG O
N TH
IS D
OCU
MEN
T W
ASAU
THO
RIZE
D BY
PAT
RICK
ASI
EDU,
P.E
. 10
5858
.TH
IS D
RAW
ING
IS IS
SUED
FO
R CO
NSTR
UCTI
ON.
THIS
DRA
WIN
G M
AY N
OT
BE M
ODI
FIED
WIT
HOUT
THE
EXPR
ESS
WRI
TTEN
CO
NSEN
T O
F TH
EEN
GIN
EER,
AND
THE
N O
NLY
IN A
CCO
RDAN
CEW
ITH
THE
RULE
S O
F TH
E TE
XAS
ENG
INEE
RING
PRAC
TICE
ACT
.
KINGSSEProject No.
Date
Drawn by Checked by
REVI
SIO
NSKI
NGS
STRU
ARCH
URAL
, INC
.
2851
, Joe
DiM
aggi
o, U
nit 2
2 Ro
und
Rock
, Tex
as 7
8665
Phon
e (5
12) 2
71-7
331
TBPE
Reg
istr
atio
n No
. F-1
3346
Sheet Name:
Sheet No.
Phase:100% CD
04/16/
18
AM PA
KIN
GS
SE
4/12
/201
8 6:
57:0
5 PM
\\Se
rver
2012
\Com
pany
\PRO
JECT
S-18
0000
\180
214
- Cam
eron
Par
k Zo
o En
try
Reno
vatio
n\Dr
awin
gs\1
8021
4 - C
amer
on P
ark
Zoo
Entr
y Re
nova
tion_
Str_
R17.
rvt
S3.0
FRAMING DETAILS
180214
CAM
ERO
N PA
RK Z
OO
ENT
RY R
ENO
VATI
ON
04/16/18
WAC
O /
MCL
ENN
AN C
OUN
TY,
TEXA
S
1/2" = 1'-0"1
FRAME ELEVATION
1" = 1'-0"2
SECTION 1" = 1'-0"
3SECTION
1" = 1'-0"4
SECTION
1" = 1'-0"5
SECTION 1" = 1'-0"
6SECTION
1" = 1'-0"7
SECTION
1" = 1'-0"8
SECTION 1" = 1'-0"
9KNIFE BRACE DETAIL
No
.D
escri
pti
on
Date
RFP 2018-053 Cameron Park Zoo Entrance Modifications
5 of 5