Page 1: Acs800 Optimal Ordering17102011

ACS800 Ordering Information

Frequency Convertersand Factory-Installed

Optional Devices

Code: 3AFY64556568Effective from: 17 October 2011Supersedes: 17 June 2011

Page 2: Acs800 Optimal Ordering17102011

Ordering Information

Updated: 12 October 2011Overview

This document consists of:- a Type Code Key- ACS800-... Type Code Sheets (=Order Sheets).

Only the ACS 800 units and the built-in optional devices specified in this document can be ordered with the codes given here. However, many of the optional devices are also available as Add-On Kits, and these kits must be ordered separately. For the Add-On Kits ordering codes, please see the ACS 800 price list.

The Type Code for ordering an ACS 800 unit consists of two parts: the characters in the first part (min. 16 characters), identify the basic product with default features. The optional devices are ordered by four-digit option codes which are separated by '+' signs. On the next page you will find an example of a Type Code Key with legends. With the aid of the Type Code Sheet you will be able to form the correct ordering code (technical definition) for the unit(s) you wish to buy.

Various combinations of and restrictions to the available options are explained in detail on the respective Option Sheets. Not released products are shown in grey

The Type Code Sheet filled in with the requested information about the basic product and quantity of the selected options can be included in the order or you can copy the correct Type Code onto your order sheet. Please send the order by Lotus Notes or by fax to the country responsible Sales Administrator in Helsinki. Type Code onto your order sheet. Please send the order by Lotus Notes or by fax to the country responsible Sales Administrator in Helsinki.

Page 3: Acs800 Optimal Ordering17102011

Type Code Key

A C S 8 0 0 - 0 1 - 0 0 7 0 - 3 + X X X X +

Product Series

Construction

Size

Voltage Rating

Option codes

Example ACS800 - 01 - 0020 - 3 + E202 + 2L501 + L503

20 kVA 400 V basic drive

EMC filter

2pcs of Digital I/O extensions RDIO-01

DDCS Communication 3

Page 4: Acs800 Optimal Ordering17102011

Ordering Information

Updated on 12 October 2011

How to fill in the Industry Segment, Application Area and Distribution Channel boxes on the Order SheetsOn the subsequent Order Sheets (Type Code Sheets), you will need to fill in the Industry Segment,Application Area and Distribution Channel boxes on top of each sheet. Below is a list of the Industry Segment, Application Area and Distribution Channel abbreviationsdefined in our Order Processing System (SAP). On the Order Sheets, you may view these using the Industry Segment, Application Area and Distribution Channel scroll bars and then select the respective abbreviations from the Industry Segment, Application Area and Distribution Channel drop-down menus.Abbreviations for Industry Segments and Application Areas (you may view these on the Order Sheets)

Industry Segments Application Areas

AUT - Automotive CAB - Cable car

CEM - Cement CAL - Calander line

CHE - Chemical CEN - CentrifugeCON - Consumer industry COA - CoatingELE - Electronics COM - CompressorFOO - Food and Beverage CON - ConveyorHVA - HVAC CRA - CraneMAH - Material handling CRU - CrusherMAR - Marine CUT - Cutting,Shear,SawMET - Metal DRI - DrillingMIN - Mining DRU - DrumMUL - Multiple segments OEM ELE - ElevatorMUL - Multiple segments OEM ELE - ElevatorOFF - Offshore EXT - ExtruderOGA - Oil and Gas field FAN - FanPAP - Pulp and Paper FLA - Flat rollingPEC - Petrochemical IND - Induction heatingPHA - Pharmaceutical KIL - KilnPRI - Printing MAC - MachinetoolPOW - Power Plant MIX - Mixer,StirrerREC - Recreation PAC - Packaging machineRUB - Rubber,Plastics PAP - Paper MachineSAW - Sawmill POW - Power ElectronicsTAD - Transmission and Distribution PRC - Processing lineTEX - Textile PRE - PressWAT - Water PRI - Printing MachineOTH - Other PRO - Profile rollingNKN - Not Known PRP - PropulsionPAR - Not known partner sales PUM - Pump

ROL - Roller tableDistribution Channels SKI - Skilift

SOL - Solar powerDSAL - Direct sales to end customer SPI - SpinningSOEM - Serial OEM TES - TestbenchPOEM - Project OEM THU - ThrusterLDIS - Electrical wholesaler WIC - WinchTDIS - Technical distributor WID - WindmillSINT - System integrator WIN - WinderAHOU - EPCC and automation house NKN - Not KnownLCEN - Local ABB logistics centers OTH - OtherPBIN - Panel builders and installers PAR - Not known partner salesAINT - ABB internal

Page 5: Acs800 Optimal Ordering17102011

Distribution Channel definitions:

Electrical Wholesalers (LDIS): Electrical Wholesalers/distributors has the ability to provide a wide range of electrical products readily available from one location. Electrical Wholesalers/distributors normally stocks leading brand name products, and the customer usually specifies the products required from the catalogue. Electrical Wholesalers/distributors channels are cost driven and normally use EDI-based ordering. This channel type includes Electrical wholesalers/distributors (e.g. in US referred as electrical distributor), and also Catalogue houses.

Technical Distributor (TDIS): Technical product and service oriented channel. A technical distributor has a good technical knowledge of the promoted product. Technical distributor offers complementary products or services, which add value to the end customer. They do their business locally, normally have a local stock and have a good working knowledge of local companies. This channel type includes Drives Specialists, Motor repair shops, Power Transmission Distributors, but partly also the ‘immaterial’ channels like contractors, specifiers, consultants, representatives and agents.

System Integrator (SINT): Technical solution oriented channel. System Integrators are specialized in providing turn key automation solutions. System Integrator has value adding complementary products and services in the offering. Business is normally done locally, and System Integrator has a good working knowledge of local companies and standards. System Integrators are focused to certain e.g. process industries.

EPCC and Automation House (AHOU): Complete automation solution oriented channel. Automation Houses are specialized in providing the complete factory automation solutions as turn key projects. Automation house uses They use one or several sub contractors to carry out the automation project. Offering covers all the industrial automation products and/or systems. They operate normally in several countries. EPCC (Engineering, Procurement and construction contractors) agrees to deliver the keys of a commissioned plant to the owner for an agreed amount

Serial OEM (SOEM): Machine manufacturers that are purchasing products on the regular basis (=serial) according to the predefined delivery schedule. The scope of supply of ABB product is also Serial OEM (SOEM): Machine manufacturers that are purchasing products on the regular basis (=serial) according to the predefined delivery schedule. The scope of supply of ABB product is also predefined and does not vary significantly from customer to customer.

Project OEM (POEM): Machine manufacturer that purchases the product according to the frame agreements made with the supplier. Purchase occurs after the project and the customer is known. The Scope of supply varies from customer to customer.

Panel Builders and Installers (PBIN): Companies taking care of electrical panel building and panel customization as well as installation of electrical equipments. Often working as sub-suppliers for other more solution orientated industrial channels. They have good knowledge about local standards.

Direct sales to end customer (DSAL): Sales directly from ABB to the end customers without using intermediaries ( = without using other channels in the list above) ABB Internal: Sales to other ABB units (stock orders, end customer not known)

Local ABB Logistic Center (LCEN): Purchases to local ABB logistic center without knowledge about the final channel to the market.

ABB Internal (AINT): Sales to other ABB business units and ABB companies

Page 6: Acs800 Optimal Ordering17102011

ACS800-01 Type Code Sheet 1 - 200 kW, Wall MountedUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 1 ConstructionChannel

10…14 - SizeFrame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6

230V 0001 0002 0003 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 00700004 0005

400V 0003 0004 0005 0011 0016 0020 0025 0030 0040 0050 0060 0100 0120 01350006 0009 0075 0165 0205

500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 01650009 0011 0105 0205 0255

690V 0011 0016 0050 0060 0070 0100 01200020 0025 0145 0175 02050030 0040

15…16 - Voltage Rating2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L517 Pulse encoder interface TTL RTAC-03

01 = Wall mounted, IP21 (UL type 1), With control panel CDP312R, No EMC filter, Standard software, Cable lead through entry, Braking chopper in frame sizes R2, R3 and R4 (only 690V), Boards without coating, One set of default language documents

L516 available only with Motion control and PMSM application softwaresL517 available only with standard control and N651, N652, N654, N668, N677, N685, N697 and N698 programs

���������� ���� ����������������

��������������������

ACS800-01 - 1 3AFY64556568

L517 Pulse encoder interface TTL RTAC-03

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

and N651, N652, N654, N668, N677, N685, N697 and N698 programs

ACS800-01 - 1 3AFY64556568

Page 7: Acs800 Optimal Ordering17102011

ACS800-01 Type Code Sheet 1 - 200 kW, Wall MountedUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control *) Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panel0J400 No control panel

Protection classB056 IP55 (UL type 12)

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

ACS800-01 - 2 3AFY64556568

ConstructionC131 Vibration dampers Only for R4, R5 and R6, not available with IP55 (B056)

C132 Marine Drive

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only

E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

Resistor brakingD150 Braking chopper Included as standard in frame sizes R2 , R3 and 690V

frame R4

E202 not available for 690V units

Coated boards included. Requires Vibration dampers (C131) which are not needed, if installed in a cabinet. Type approval of classicication socities. Only ABS, BV and Lloyd's for -0135-3, -0165-3, -0165-5, -0205-5, -0145-7, -0175-7 and -0205-7. ABS and BV for -0075-3, -0105-5, -0205-3 and -0255-5

ACS800-01 - 2 3AFY64556568

Page 8: Acs800 Optimal Ordering17102011

ACS800-01 Type Code Sheet 1 - 200 kW, Wall MountedUpdated on 12 October 2011

CablingH358 Cable conduit entry (US & UK version)

Safety featuresQ950 Prevention of unexpected start-up Not with Q967

Q967 Safe torque off STO, without safety relay Not with Q950

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

SpecialitiesP901 Coated boards Not applicable with C132

P904 Extended warranty

Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

ACS800-01 - 3 3AFY64556568 ACS800-01 - 3 3AFY64556568

Page 9: Acs800 Optimal Ordering17102011

ACS800-02 Type Code Sheet 90 - 500 kW, Free standingUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 2 ConstructionChannel

10…14 - SizeFrame Size R7 Frame Size R8

230V 0080 0100 0140 0170 02100120 0230 0260 0300

400V 0140 0170 0260 0320 04000210 0440 0490

500V 0170 0210 0320 0400 04400260 0490 0550 0610

690V 0140 0170 0320 0400 04400210 0260 0490 0550 0610

15…16 - Voltage Rating2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

02 = Free standing, 6 pulse diode bridge, IP21 (UL type 1), With control panel CDP312R, No EMC filter, Standard software, Bottom entry and exit of cables, Cable lead through entry, Boards without coating, One set of default language documents

L516 available only with Motion

���������� ���� ����������������

��������������������

ACS800-02 - 1 3AFY64556568

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L517 Pulse encoder interface TTL RTAC-03

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

L516 available only with Motion control and PMSM control

L517 available only with standard control and N651, N652, N654, N668, N677, N685, N697 and N698 programs

ACS800-02 - 1 3AFY64556568

Page 10: Acs800 Optimal Ordering17102011

ACS800-02 Type Code Sheet 90 - 500 kW, Free standingUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panel0J400 No control panel

Filters

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

ACS800-02 - 2 3AFY64556568

FiltersE210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

E208 Common mode filter

Resistor brakingD150 Braking chopper

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

SpecialitiesP901 Coated boards

P904 Extended warranty

E202 not available for 690V units neither for R8 frame size

ACS800-02 - 2 3AFY64556568

Page 11: Acs800 Optimal Ordering17102011

ACS800-04 Type Code Sheet 1 - 200 kW, Drive moduleUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 4 ConstructionChannel

10…14 - SizeFrame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6

230V 0001 0002 0003 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 00700004 0005

400V 0003 0004 0005 0011 0016 0020 0025 0030 0040 0050 0060 0100 0120 01350006 0009 0023 0035 0075 0165 0205

500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 01650009 0011 0028 0045 0105 0205 0255

690V 0011 0016 0050 0060 0070 0100 01200020 0025 0145 0175 02050030 0040

15…16 - Voltage Rating2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L517 Pulse encoder interface TTL RTAC-03

04 = Module, IP20 (UL Open type),No control panel, No EMC filter, Standard application software, Braking chopper in frame sizes R2, R3 and R4 (only 690V), Boards without coating, One set of default language documents

L516 available only with Motion control and PMSM controlL517 available only with standard application program and N651, N652, N654, N668, N677, N685, N697 and N698 programs

���������� ���� ����������������

��������������������

���������� ���� ����������������

��������������������

ACS800-04 (R2-R6) - 1 3AFY64556568

L517 Pulse encoder interface TTL RTAC-03

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement With motion control sw it is possible to have 1 or 2 pulse encoder/resolver interfaces Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

ACS800-04 (R2-R6) - 1 3AFY64556568 ACS800-04 (R2-R6) - 1 3AFY64556568

Page 12: Acs800 Optimal Ordering17102011

ACS800-04 Type Code Sheet 1 - 200 kW, Drive moduleUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panelJ400 CDP312R control panel in module (in R2 - R4 includes also the J414 holder)

J414 Control panel holder for frame sizes R2 - R4 (not to be used with J400 option)

ConstructionC132 Marine Drive

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

Coated boards included. Type approval of classicication socities. Only ABS, BV and Lloyd's for -0135-3, -0165-3, -0165-5, -0205-5, -0145-7, -0175-7 and -0205-7. ABS and

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

ACS800-04 (R2-R6) - 2 3AFY64556568

C132 Marine Drive

C135 Flange mounting

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only

E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

Resistor brakingD150 Braking chopper

Safety featuresQ950 Prevention of unexpected start-up Not with Q967

Q967 Safe torque off STO, without safety relay Not with Q950

Included as standard in frame sizes R2 , R3 and 690V frame R4

E202 not available for 690V units

C135: Flange mounting plate ready assembled. Heat sink side IP55, front side IP20.

Coated boards included. Type approval of classicication socities. Only ABS, BV and Lloyd's for -0135-3, -0165-3, -0165-5, -0205-5, -0145-7, -0175-7 and -0205-7. ABS and BV for -0075-3, -0105-5, -0205-3 and -0255-5

Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

ACS800-04 (R2-R6) - 2 3AFY64556568 ACS800-04 (R2-R6) - 2 3AFY64556568

Page 13: Acs800 Optimal Ordering17102011

ACS800-04 Type Code Sheet 1 - 200 kW, Drive moduleUpdated on 12 October 2011

Documentation language0R715 No documentation

R700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

SpecialitiesP901 Coated boards Not applicable with C132

P904 Extended warranty

+0R715: Module is delivered without manuals. This needs to be approved by customer.

ACS800-04 (R2-R6) - 3 3AFY64556568 ACS800-04 (R2-R6) - 3 3AFY64556568 ACS800-04 (R2-R6) - 3 3AFY64556568

Page 14: Acs800 Optimal Ordering17102011

ACS800-04 Type Code Sheet 90 - 560 kW, Drive moduleUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 4 ConstructionChannel

10…14 - SizeFrame Size R7 Frame Size R8

230V 0080 0100 0140 0170 02100120 0230 0260 0300

400V 0140 0170 0260 0320 04000210 0440 0490

500V 0170 0210 0320 0400 04400260 0490 0550 0610

690V 0140 0170 0320 0400 04400210 0260 0490 0550 0610

15…16 - Voltage Rating2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

04 = Drive module, 6 pulse diode bridge, IP00 (UL Open type), Top entry of cables, side exit, RDCU motor control and I/O unit, No control panel, No EMC filter, Standard software, Boards without coating, Bookshelf pedestal with output busbars for motor, Bars for floor and wall fixing, One set of default language documents

L516 available only with Motion control and PMSM controlL517 available only with standard

���������� ���� ����������������

��������������������

ACS800-04(R7-R8) - 1 3AFY64556568

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L517 Pulse encoder interface TTL RTAC-03

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement With motion control sw it is possible to have 1 or 2 pulse encoder/resolver interfaces Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

L516 available only with Motion control and PMSM controlL517 available only with standard application program and N651, N652, N654, N668, N677, N685, N697 and N698 programs

ACS800-04(R7-R8) - 1 3AFY64556568

Page 15: Acs800 Optimal Ordering17102011

ACS800-04 Type Code Sheet 90 - 560 kW, Drive moduleUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panelJ400 CDP 312R control panel (incl. 3 m control panel cable)

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

ACS800-04(R7-R8) - 2 3AFY64556568

J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)

J413

FiltersE210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network

E208 Common mode filter

Resistor brakingD150

Pedestal0H354 No pedestal

Braking chopper (Including output busbar kit for braking chopper and DC unless +0H354 has been selected)

RPMP-21 control panel mounting platform ("pocket" model to be mounted inside the enclosure without control panel)

ACS800-04(R7-R8) - 2 3AFY64556568

Page 16: Acs800 Optimal Ordering17102011

ACS800-04 Type Code Sheet 90 - 560 kW, Drive moduleUpdated on 12 October 2011

Safety featuresQ950 Prevention of unexpected start-up Not with Q967

Q967 Safe torque off STO, without safety relay Not with Q950

Documentation language0R715 No documentation

R700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

SpecialitiesP901 Coated boards

P904 Extended warranty

+0R715: Module is delivered without manuals. This needs to be approved by customer.

Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

ACS800-04(R7-R8) - 3 3AFY64556568ACS800-04(R7-R8) - 3 3AFY64556568

Page 17: Acs800 Optimal Ordering17102011

ACS800-04M Type Code Sheet 90 - 560 kW, Drive moduleUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 4 M ConstructionChannel

10…14 - SizeFrame Size R7 Frame Size R8

230V 0080 0100 0140 0170 02100120 0230 0260 0300

400V 0140 0170 0260 0320 04000210 0440 0490

500V 0170 0210 0320 0400 04400260 0490 0550 0610

690V 0140 0170 0320 0400 04400210 0260 0490 0550 0610

15…16 - Voltage Rating2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

04M = Modular drive module, 6 pulse diode bridge, IP00 (UL Open type), Top entry of cables, exit requires pedestal, RDCU motor control and I/O unit, No control panel, No EMC filter, Standard software, Boards without coating, No pedestal, No output busbars, One set of default language documents, Pedestal & mechanical accessories delivered as loose parts

L516 available only with Motion control and PMSM control

���������� ���� ����������������

��������������������

ACS800-04M - 1 3AFY64556568

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L517 Pulse encoder interface TTL RTAC-03

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement With motion control sw it is possible to have 1 or 2 pulse encoder/resolver interfaces Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

L516 available only with Motion control and PMSM controlL517 available only with standard application program and N651, N652, N654, N668, N677, N685, N697 and N698 programs

ACS800-04M - 1 3AFY64556568

Page 18: Acs800 Optimal Ordering17102011

ACS800-04M Type Code Sheet 90 - 560 kW, Drive moduleUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panelJ400 CDP 312R control panel (incl. 3 m control panel cable)

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

ACS800-04M - 2 3AFY64556568

J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)

J413

FiltersE210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

E208 Common mode filter

Resistor brakingD150 Braking chopper (if +H354 or +H360 are selected, select also +H356)

Pedestal, pedestal accessoriesH352

H354 Bookshelf pedestal (alternatives H352 and H360)

H360 Flat type ("side against wall") mounting pedestal (alternatives H352 and H354)

H356 Pedestal busbar kit for DC and braking chopper outputs (requires +H354 or +H360)

H355

H362

H363

RPMP-21 control panel mounting platform ("pocket" model to be mounted inside the enclosure without control panel)

Vertical busbars for motor output cable connection (incl. also supports for busbars). Requires +H354 or +H360.

Kit for DC and brake outputs on different sides (one long horisontal pedestal busbar, one extra vertical busbar, one extra support for vertical busbars). Requires +H354 AND +H356.

Vertical busbars for DC and braking chopper output cable connection. Requires pedestal +H354 or +H360 and DC busbar kit +H356.

Bottom exit kit (available only for R7; wall mounting; includes DC and braking chopper busbars; alternatives H354 and H360)

E202 not available for 690V units

ACS800-04M - 2 3AFY64556568

Page 19: Acs800 Optimal Ordering17102011

ACS800-04M Type Code Sheet 90 - 560 kW, Drive moduleUpdated on 12 October 2011

Safety featuresQ950 Prevention of unexpected start-up Not with Q967

Q967 Safe torque off STO, without safety relay Not with Q950

B060

Documentation language0R715 No documentation

R700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

SpecialitiesP901 Coated boards

P904 Extended warranty

IP20 shroud. Available only for R7 frame size bottom exit version (+H352) and R8 frame size bookshelf version with vertical busbars (+H354 +H355).

+0R715: Module is delivered without manuals. This needs to be approved by customer.

Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

ACS800-04M - 3 3AFY64556568ACS800-04M - 3 3AFY64556568

Page 20: Acs800 Optimal Ordering17102011

ACS800-U1 Type Code Sheet 1 - 200 HP, Wall MountedUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 1 ConstructionChannel

10…14 - SizeFrame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6

230V 0002 0003 0004 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 0070

500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 02050009 0011 0105

690V 0011 0016 0050 0060 0070 0100 0120(600V) 0020 0025 0145 0175 0205

0030 0040

15…16 - Voltage Rating2 = 230 V 5 = 500 V 7 = 690 V (600V)

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L517 Pulse encoder interface TTL RTAC-03

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

U1 = Wall mounted (USA), UL type1 (IP21), With control panel CDP312R, No EMC filter, Standard software (US), Cable conduit entry, Braking chopper in frame sizes R2, R3 and R4 (only 600V), Boards without coating, One set of default language documents

1 or 2 Digital extensions

L516 available only with Motion control and PMSM controlL517 available only with standard application program and N651, N652, N654, N668, N677, N685, N697 and N698 programs

���������� ���� ����������������

��������������������

ACS800-U1 - 1 3AFY64556568

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

FieldbusK451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

ACS800-U1 - 1 3AFY64556568

Page 21: Acs800 Optimal Ordering17102011

ACS800-U1 Type Code Sheet 1 - 150 HP, Wall MountedUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panel0J400 No control panel

Protection classB056 IP55 (UL type 12)

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

ACS800-U1 - 2 3AFY64556568

ConstructionC131 Vibration dampers Only for R4, R5 and R6, not available with UL type 12 (B056)

C132 Marine Drive

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only

E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

Resistor brakingD150 Braking chopper

CablingH357 Cable lead through entry (European)

E202 not available for 690V units

Included as standard in frame sizes R2 , R3 and 690V (600V) frame R4

Coated boards included. Requires Vibration dampers (C131) which are not needed, if installed in a cabinet. Type approval of classicication socities. Only ABS, BV and Lloyd's for -0205-5, -0145-7, -0175-7 and -0205-7

ACS800-U1 - 2 3AFY64556568

Page 22: Acs800 Optimal Ordering17102011

ACS800-U1 Type Code Sheet 1 - 150 HP, Wall MountedUpdated on 12 October 2011

Safety featuresQ950 Prevention of unexpected start-up Not with Q967

Q967 Safe torque off STO, without safety relay Not with Q950

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

SpecialitiesP901 Coated boards Not applicable with C132

P904 Extended warranty

Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

ACS800-U1 - 3 3AFY64556568 ACS800-U1 - 3 3AFY64556568

Page 23: Acs800 Optimal Ordering17102011

ACS800-U4 Type Code Sheet 150 - 600 HP, Drive moduleUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 4 ConstructionChannel

10…14 - SizeFrame Size R7 Frame Size R8

230V 0080 0100 0140 0170 02100120 0230 0260 0300

500V 0170 0210 0270 0300 0320 04000260 0440 0490 0550 0610

690V 0140 0170 0320 0400 04400210 0260 0490 0550 0610

15…16 - Voltage Rating2 = 230 V 5 = 500 V 7 = 690 V

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

U4 = Drive module (USA), 6 pulse diode bridge, UL Open type (IP00), Top entry of cables, side exit, RDCU motor control and I/O unit, No control panel, No EMC filter, Standard software (US), Common mode filter in R8, Bookshelf pedestal with output busbars for motor, Bars for floor and wall fixing, One set of default language documents

L516 available only with Motion control and PMSM controlL517 available only with standard application program and N651, N652, N654, N668, N677, N685, N697 and N698 programs

���������� ���� ����������������

��������������������

ACS800-U4 - 1 3AFY64556568

L517 Pulse encoder interface TTL RTAC-03

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement With motion control sw it is possible to have 1 or 2 pulse encoder/resolver interfaces Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

N654, N668, N677, N685, N697 and N698 programs

ACS800-U4 - 1 3AFY64556568

Page 24: Acs800 Optimal Ordering17102011

ACS800-U4 Type Code Sheet 150 - 600 HP, Drive moduleUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panelJ400 CDP 312R control panel (incl. 3 m control panel cable)

J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

ACS800-U4 - 2 3AFY64556568

J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)

J413

FiltersE210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network

E208 Common mode filter (Only for R7)

Resistor brakingD150

Pedestal0H354 No pedestal

Documentation language0R715 No documentation

R700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

SpecialitiesP901 Coated boards

P904 Extended warranty

Braking chopper (Including output busbar kit for braking chopper and DC unless +0H354 has been selected)

RPMP-21 control panel mounting platform ("pocket" model to be mounted inside the enclosure without control panel)

+0R715: Module is delivered without manuals. This needs to be

P904 Extended warranty

ACS800-U4 - 2 3AFY64556568

Page 25: Acs800 Optimal Ordering17102011

ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 7 ConstructionChannel

10…14 - Size

Frame Size R5 R6 R7 R8

400V 0075 0100 0120 0135 0260 0320 04000165 0205 0440 0490

500V 0105 0120 0140 0165 0320 0400 04400205 0255 0490 0550 0610

690V 0070 0100 0120 0320 0400 04400145 0175 0205 0260 0490 0550 0610

15…16 - Voltage Rating3 = 400 V 5 = 500 V 7=690 V

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters as standard

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

07 = Cabinet built, IP21 (UL type1), Main switch fuse with aR fuses, 230 VAC control voltage, Control Panel CDP312R, No EMC filter, Standard software, Bottom entry and exit of cables, Cable lead through entry, Boards without coating, One set of default language documents

L516 available only with PMSM

��������������������

���������� ���� ����������������

ACS800-07(R5-R8) - 1 3AFY64556568

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

L504 Additional I/O-Terminal Block

L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)

L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)

L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)

L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)

L515 I/O extension adapter Requires DDCS communication

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

K453 Interbus-S adapter NIBA-01

K456 AF100 adapter NAFA-01

Standard control supports 3 Digital extensions and 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

N-type fieldbus adapters require DDCS Communication board.Add L503 or L509 to code

L516 available only with PMSM control

I/O extension adapter (requires DDCS communication), adds three slots for I/O extension and Pulse encoder. Check compatibility with different application softwares.

ACS800-07(R5-R8) - 1 3AFY64556568

Page 26: Acs800 Optimal Ordering17102011

ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Protection classB053 IP22 (UL type 1)

B054 IP42 (UL type 1)

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

ACS800-07(R5-R8) - 2 3AFY64556568

B054 IP42 (UL type 1)

B055 IP54 (UL type 12)

B059 IP54R

ConstructionC121 Marine construction

C129 UL listed

C134 CSA approved

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frame R5 only

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, not for frame R5

E205 Du/dt limitation by choke

E208 Common mode filter

E206 Sine output filter

C134 Includes US/CSA type main switch fuse, Bottom entry and exit, 115VAC control voltage, US Cable conduit entry, all components UL/CSA listed/recognized, max. supply voltage 600 V

Reinforced mechanics and fastening, door handels, self extinctive materials, requires marking of conductors (G338-G342)Not available with C129 or C134

E206 is not available for R5 and R6 except 0135-3, 0205-3, 0165-5, 0255-5, 0145-7 and 0175-7. Not available for 0260-7, 0490-7, 0610-7 or with C121, C129 or E205. Available output current reduced for some types

Not for 690V, adds width by 200 mm for R7, 400 mm for R8

C129 includes US type main switch fuse, Top entry and exit,115VAC control voltage, US Cable conduit entry, all components UL listed/recognized, max. supply voltage 600 V

E208 is not available for R5 and R6 except 0135-3, 0165-3, 0205-3, 0165-5, 0205-5, 0255-5, 0145-7, 0175-7 and 0205-7

ACS800-07(R5-R8) - 2 3AFY64556568

Page 27: Acs800 Optimal Ordering17102011

ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

Resistor brakingD150 Braking chopper

D151 Braking resistor

Line fusesF251 gG line fuses

Line optionsF250 Line contactor

CablingH351 Top entry (included with C129)

H353 Top exit (included with C129)

H350 Bottom entry (only with C129)

H352 Bottom exit (only with C129)

H356 DC cable connection busbars

H358 Cable conduit entry (US & UK version) (Included with C129 or C134)

Control voltageG304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet optionsG300 Cabinet heater (External supply) (Not available with C134)

G313 Output for Motor heater (External supply)

G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)

G330 Halogen free wiring and materials (Not available with C129 or C134)

G338 Wire marking class A1

Braking resistor is not available as IP54, IP54R, or with C121, C129 or C134. Available output current reduced for some types

Replaces standard aR fuses, not available with C129 or C134

Class A1, equipment pin numbers printed on conductors, conductors to terminal blocks not marked

ACS800-07(R5-R8) - 3 3AFY64556568

G338 Wire marking class A1

G339 Wire marking class A2

G340 Wire marking class A3

G341 Wire marking class B1

G342 Wire marking class C1

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Class A1, equipment pin numbers printed on conductors, conductors to terminal blocks not markedClass A2, equipment and terminal block pin numbers printed on conductorsClass A3, like A2 but marking by ringsClass B1, equipment and terminal block pin numbers and equipment Ids marked by ringsClass C1, like B1 but remote end address is also marked

ACS800-07(R5-R8) - 3 3AFY64556568

Page 28: Acs800 Optimal Ordering17102011

ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

Starter for auxiliary Motor fanM600 1...1,6 A (1 pc)

M601 1,6...2,5 A (1 pc)

M602 2,5...4 A (1 pc)

M603 4...6,3 A (1 pc)

M604 6,3...10 A (1 pc)

M605 10...16 A (1 pc)

Safety features

Q950 Prevention of unexpected start up Not with Q968,Q963,Q964, Q971

Q951 Emergency Stop, Category 0 with opening main contactor/breaker

Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)

Q963 Emergency Stop, Category 0 without opening main contactor/breaker

Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)

Q968 Safe torque off STO, with safety relay Not with Q950

Q954 Earth Fault Monitoring, Unearthed Mains

Q971 ATEX certified safety function Only with L513 and L514, not with Q950

SpecialitiesP901 Coated boards

P902 Customised (Described in Technical appendix)

P904 Extended warranty

P913 Special colour (Described in Technical appendix)

M604 and M605 are not available for R5 or R6 except 0165-3, 0205-3, 0205-5, 0255-5, 0175-7 and 0205-7

Q951 and Q952 require line contactor F250

* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge- or Permanent Magnet Control Std application (add +L501 to code)

ACS800-07(R5-R8) - 4 3AFY64556568

P913 Special colour (Described in Technical appendix)

ACS800-07(R5-R8) - 4 3AFY64556568

Page 29: Acs800 Optimal Ordering17102011

ACS800-U7 Type Code Sheet 150 - 600 HP, Cabinet builtUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 7 ConstructionChannel

10…14 - Size

Frame Size R6 R7 R80270 0300

500V 0100 0120 0140 0320 0400 04400165 0205 0490 0550 0610

690V(600V) 0070 0100 0120 0320 0400 0440

0145 0175 0205 0260 0490 0550 0610

15…16 - Voltage Rating5 = 500 V 7=690 V (600V)

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

U7 = Cabinet built(USA), UL type1 (IP21), US type main switch fuse, 115VAC control voltage, Control panel CDP312R, No EMC filter, Standard software (US), Top entry and exit of cables, Cable conduit entry, Common mode filter in R8, One set of default language documents

L516 available only with PMSM control

��������������������

���������� ���� ����������������

ACS800-U7(R6-R8) - 1 3AFY64556568

L516 Resolver interface RRIA-01

L503 DDCS Communication 3 RDCO-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

L504 Additional I/O-Terminal Block

L505 Thermistor Relay (1 or 2 pcs) (Not with L506)

L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505)

L515 I/O extension adapter Requires DDCS communication

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

K453 Interbus-S adapter NIBA-01

K456 AF100 adapter NAFA-01

N-type fieldbus adapters require DDCS Communication board.Add L503 or L509 to code

Standard control supports 3 Digital extensions and 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

I/O extension adapter (requires DDCS communication), adds three slots for I/O extension and Pulse encoder. Check compatibility with different application softwares.

control

ACS800-U7(R6-R8) - 1 3AFY64556568

Page 30: Acs800 Optimal Ordering17102011

ACS800-U7 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Protection classB054 IP42 (UL type 1)

Master follower includes optic fibres, requires DDCS communication (add L503, L509 or L508 to code)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

ACS800-U7(R6-R8) - 2 3AFY64556568

B055 IP54 (UL type 12)

FiltersE202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network

E205 Du/dt limitation by choke

E208 Common mode filter

Resistor brakingD150 Braking chopper

Line optionsF250 Line contactor

CablingH350 Bottom entry

H352 Bottom exit

H356 DC cable connection busbars

H357 Cable lead through entry (European)

Control voltageG320 230 VAC Control Voltage

Not for 690V, adds width by 200 mm for R7, 400 mm for R8

Standard in R8, not available for R5 and R6 except 0135-3, 0165-3, 0205-3, 0165-5, 0205-5, 0255-5, 0145-7, 0175-7 and 0205-7

ACS800-U7(R6-R8) - 2 3AFY64556568

Page 31: Acs800 Optimal Ordering17102011

ACS800-U7 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

Cabinet optionsG300 Cabinet heater (External supply)

G313 Output for Motor heater (External supply)

G307 Terminals for External Control Voltage 230 VAC or 115 VAC (UPS)

G330 Halogen free wiring and materials

G338 Wire marking class A1

G339 Wire marking class A2

G340 Wire marking class A3

G341 Wire marking class B1

G342 Wire marking class C1

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan

Class A1, equipment pin numbers printed on conductors, conductors to terminal blocks not markedClass A2, equipment and terminal block pin numbers printed on conductorsClass A3, like A2 but marking by ringsClass B1, equipment and terminal block pin numbers and equipment Ids marked by ringsClass C1, like B1 but remote end address is also marked

ACS800-U7(R6-R8) - 3 3AFY64556568

Starter for auxiliary Motor fanM600 1...1,6 A (1 pc)

M601 1,6...2,5 A (1 pc)

M602 2,5...4 A (1 pc)

M603 4...6,3 A (1 pc)

M604 6,3...10 A (1 pc)

M605 10...16 A (1 pc)

Safety features

Q950 Prevention of unexpected start up Not with Q968,Q963,Q964

Q951 Emergency Stop, Category 0 with opening main contactor/breaker

Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)

Q963 Emergency Stop, Category 0 without opening main contactor/breaker Not with Q950

Q964 Emergency Stop, Category 1 without opening main contactor/breaker *) Not with Q950

Q968 Safe torque off STO, with safety relay Not with Q950

Q954 Earth Fault Monitoring, Unearthed Mains

SpecialitiesP901 Coated boards

P902 Customised (Described in Technical appendix)

P904 Extended warranty

P913 Special colour (Described in Technical appendix)

M604 and M605 are not available for R5 or R6 except 0165-3, 02053, 0205-5, 0255-5, 0175-7 and 0205-7

* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge- or Permanent Magnet Control Std application (add +L501 to code)

Q951 and Q952 require line contactor (add F250 to

ACS800-U7(R6-R8) - 3 3AFY64556568

Page 32: Acs800 Optimal Ordering17102011

ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet builtUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 7 ConstructionChannel

10…14 - Size

Frame Size 2xR8i 3xR8i 4xR8i 5xR8i 6xR8i1xD4 2xD4 2xD4 3xD4 2xD4 3xD4 3xD4 3xD4 4xD4

400V 0610 0770 1230 1540 185008701030

500V 0760 0910 1540 1820 231010901210

690V 0750 1160 1500 2120 2320 2900 3190 34900870 17401060

15…16 - Voltage Rating3 = 400 V 5 = 500 V 7=690 V

+V992 Equipped with the new DSU module

Option codes

07 = Cabinet built, IP21 (UL type1), Main Switch, 230 VAC control voltage, Control panel CDP312R, DDCS communication RDCO-03, EMC/RFI-filter 2nd Environment, Du/dt limitation by choke, Common mode filter, Standard software, Bottom entry and exit of cables, Cable lead through entry, Coated boards, One set of default language documents

��������������������

���������� ���� ����������������

ACS800-07(nxR8i) - 1 3AFY64556568

Option codesI/O options 2 slots available for I/O options or Fieldbus adapters as standard

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

L504 Additional I/O-Terminal Block

L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)

L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)

L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)

L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513) I/O extension adapter Requires DDCS communication

L515 I/O extension adapter Requires DDCS communication

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

K453 Interbus-S adapter NIBA-01N-type Fieldbus adapters require DDCS Communication board.

Standard control supports 3 Digital extensions and 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used

L516 available only with PMSM

RDCO-02 and RDCO-01 will replace standard RDCO-03

I/O extension adapter adds three slots for I/O extension and Pulse encoder. Check compatibility with different application softwares.

K456 AF100 adapter NAFA-01

Communication board.

ACS800-07(nxR8i) - 1 3AFY64556568

Page 33: Acs800 Optimal Ordering17102011

ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet builtUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N654 Spinning control

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Protection classB053 IP22 (UL type 1)

B054 IP42 (UL type 1)

Software compatibility with different option modules must be checked from ACS800 software compatibility document (doc no. 3AFE64638211) in ABB Library

Master follower includes optic fibres, requires DDCS communication (add L509 or L508 to code)

ACS800-07(nxR8i) - 2 3AFY64556568

B054 IP42 (UL type 1)

B055 IP54 (UL type 12)

B059 IP54R

ConstructionC121 Marine construction

C129 UL listed

C134 CSA approved

FiltersE202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

E206 Sine output filter

Resistor braking (standard option only for 2xR8i)D150 Braking chopper

D151 Braking resistor

Reinforced mechanics and fastening, door handels, self extinctive materials, requires marking of conductors (G338-G342) Not available with C129 or C134

C134 includes 115VAC control voltage, Bottom entry and exit, US Cable conduit entry, all components UL/CSA listed/recognized, max. supply voltage 600 V

EMC filter only for 6-pulse 0610-3 and 0760-5, requires Load switch, Line fuses+additional field. Add F253 and F260 to code

Braking resistor is not available as IP54, IP54R, or with C129 or C134. Marine construction C121 available only for 500V and 690V. Available output current reduced for some types

Sine filter is not available with

C129 includes aR line fuses and Load switch, Top entry and exit, 115VAC control voltage, US Cable conduit entry, all components UL listed/recognized, max. supply voltage 600 V. 3xD4 and 4xD4 require 12-pulse operation A004 or Air circuit breaker F255

ACS800-07(nxR8i) - 2 3AFY64556568

Page 34: Acs800 Optimal Ordering17102011

ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet builtUpdated on 12 October 2011

Line optionsF250 Line contactor

Line options, not available with C129 (UL listed)

F253+F260 aR Line fuses and Load switch, 6-pulse operation

A004+F253+F260 aR Line fuses and Load switch, 12-pulse operation

F255+F260 Air circuit breaker, aR Line fuses, 6-pulse operation

F259 Earthing switch (only with F253 or F255, not available with C129/C134)

Line options available only with UL C129 (one of these required always with 3xD4 and 4xD4)

A004 12-pulse operation, includes two fields

F255 Air circuit breaker, 6-pulse operation

CablingH351 Top entry (included with C129)

H353 Top exit (included with C129)

H350 Bottom entry (only with C129)

H352 Bottom exit (only with C129)

H358 Cable conduit entry (US & UK version) (Included with C129 or C134)

H359 Common motor terminal cubicle

F250 and F255 are alternative options

Air circuit breaker is alternative to Load switch F253, not available with 1xD4. Load switches inside DSU modules are removed

F253 includes additional field with input terminals. Load switches inside DSU modules are removedLimitation with CSA C134: 6-pulse not available with 3xD4 or 4xD4

IP54 or IP54R with top entry require Load switch F253 or Air circuit breaker F255. Dimensions may increase.

Air circuit breaker replaces Load switch, not available with 1xD4.

ACS800-07(nxR8i) - 3 3AFY64556568

Control voltage

G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet optionsG300 Cabinet heater (External supply) (Not available with C134)

G313 Output for Motor heater (External supply)

G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)

G317 Busbar Supply Conductors (6-pulse only, requires load switch F253 or air circuit breaker F255)

G330 Halogen free wiring and materials (Not available with C129 or C134)

G338 Wire marking class A1

G339 Wire marking class A2

G340 Wire marking class A3

G341 Wire marking class B1

G342 Wire marking class C1

Class A1, equipment pin numbers printed on conductors, conductors to terminal blocks not markedClass A2, equipment and terminal block pin numbers printed on conductorsClass A3, like A2 but marking by ringsClass B1, equipment and terminal block pin numbers and equipment Ids marked by ringsClass C1, like B1 but remote end address is also marked

ACS800-07(nxR8i) - 3 3AFY64556568

Page 35: Acs800 Optimal Ordering17102011

ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet builtUpdated on 12 October 2011

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan

M602 2,5...4 A (1,2 or 4 pcs)

M603 4...6,3 A (1,2 or 4 pcs)

M604 6,3...10 A (1,2 or 4 pcs)

M605 10...16 A (1 or 2 pcs)

M606 17…25 A (1 pc)

Safety featuresQ950 Prevention of unexpected start up Not with Q968,Q963,Q964, Q971

Q951 Emergency Stop, Category 0 with opening main contactor/breaker

Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)

Q951 and Q952 require line contactor F250 or breaker F255

ACS800-07(nxR8i) - 4 3AFY64556568

Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)

Q963 Emergency Stop, Category 0 without opening main contactor/breaker

Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)

Q968 Safe torque off STO, with safety relay Not with Q950

Q954 Earth Fault Monitoring, Unearthed Mains

Q959 Red tripping push button for external breaker

Q971 ATEX certified safety function Only with L513 and L514, not with Q950

SpecialitiesP902 Customised (Described in Technical appendix)

P904 Extended warranty

P913 Special colour (Described in Technical appendix)

* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge- or Permanent Magnet Control Std application (add +L501 to code)

line contactor F250 or breaker F255

ACS800-07(nxR8i) - 4 3AFY64556568

Page 36: Acs800 Optimal Ordering17102011

ACS800-11 Type Code Sheet 7.5 - 110 kW, Wall MountedUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 1 1 ConstructionChannel

10…14 - SizeFrame Size R5 Frame Size R6

230V 0011 0016 0020 0040 00500025 0030 0060

400V 0016 0020 0025 0060 00700030 0040 0050 0100

500V 0020 0025 0030 0070 01000040 0050 0060 0120

690V 0060 00700100

15…16 - Voltage Rating2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codes

11 = Wall mounted regenerative drive, IP21, With control panel CDP312R, RDCO-03, No EMC filter, Standard software, Cable lead through entry, Boards with coating, One set of default language documents.

���������� ���� ����������������

��������������������

ACS800-11 - 1 3AFY64556568

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L517 Pulse encoder interface TTL RTAC-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

L516 available only with Motion control and PMSM control

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement With motion control sw it is possible to have 1 or 2 pulse encoder/resolver interfaces Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

ACS800-11 - 1 3AFY64556568

Page 37: Acs800 Optimal Ordering17102011

ACS800-11 Type Code Sheet 7.5 - 110 kW, Wall MountedUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N668 Traverse control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panel0J400 No control panel

Software compatibility with different option modules must be checked from ACS800 software compatibility (doc no. 3AFE64638211) in ABB Library.

ACS800-11 - 2 3AFY64556568

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

CablingH358 Cable conduit entry (US & UK version)

Safety featuresQ950 Prevention of unexpected start-up Not with Q967

Q967 Safe torque off STO, without safety relay Not with Q950

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Specialities

P904 Extended warranty

Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

E202 not available for 690V units

P904 Extended warranty

ACS800-11 - 2 3AFY64556568

Page 38: Acs800 Optimal Ordering17102011

ACS800-U11 Type Code Sheet 10 - 125 HP, Wall MountedUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 1 1 ConstructionChannel

10…14 - SizeFrame Size R5 Frame Size R6

230V 0011 0016 0020 0040 00500025 0030 0060

500V 0020 0025 0030 0070 01000040 0050 0060 0120

690V 0060 0070(600V) 0100

15…16 - Voltage Rating2 = 230 V 5 = 500 V 7 = 690 V (600V)

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

U11 = Wall mounted regenerative drive (USA), IP21, With control panel CDP312R, RDCO-03, No EMC filter, Standard software (US), Cable conduit entry, Boards with coating, One set of default language documents.

���������� ���� ����������������

��������������������

ACS800-U11 - 1 3AFY64556568

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L517 Pulse encoder interface TTL RTAC-03

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

L516 available only with Motion control and PMSM control

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement With motion control sw it is possible to have 1 or 2 pulse encoder/resolver interfaces Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

ACS800-U11 - 1 3AFY64556568

Page 39: Acs800 Optimal Ordering17102011

ACS800-U11 Type Code Sheet 10 - 125 HP, Wall MountedUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panel0J400 No control panel

Filters

Software compatibility with different option modules must be checked from ACS800 software compatibility (doc no. 3AFE64638211) in ABB Library..

ACS800-U11 - 2 3AFY64556568

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

CablingH357 Cable lead through entry (European)

Safety featuresQ950 Prevention of unexpected start-up Not with Q967

Q967 Safe torque off STO, without safety relay Not with Q950

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Specialities

P904 Extended warranty

E202 not available for 690V units

Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

ACS800-U11 - 2 3AFY64556568

Page 40: Acs800 Optimal Ordering17102011

ACS800-31 Type Code Sheet 7.5 - 110 kW, Wall MountedUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 3 1 ConstructionChannel

10…14 - SizeFrame Size R5 Frame Size R6

230V 0011 0016 0020 0040 00500025 0030 0060

400V 0016 0020 0025 0060 00700030 0040 0050 0100

500V 0020 0025 0030 0070 01000040 0050 0060 0120

690V 0060 00700100

15…16 - Voltage Rating2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codes

31 = Wall mounted low harmonic drive, IP21, With control panel CDP312R, RDCO-03, No EMC filter, Standard software, Cable lead through entry, Boards with coating, One set of default language documents.

���������� ���� ����������������

��������������������

ACS800-31 - 1 3AFY64556568

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

L516 available only with PMSM control

ACS800-31 - 1 3AFY64556568

Page 41: Acs800 Optimal Ordering17102011

ACS800-31 Type Code Sheet 7.5 - 110 kW, Wall MountedUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N685 Motion control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panel0J400 No control panel

Filters

Software compatibility with different option modules must be checked from ACS800 software compatibility (doc no. 3AFE64638211) in ABB Library.

ACS800-31 - 2 3AFY64556568

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

CablingH358 Cable conduit entry (US & UK version)

Safety featuresQ967 Safe torque off STO, without safety relay

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Specialities

P904 Extended warranty

E202 not available for 690V units

Separate gate driver power supply board (ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

ACS800-31 - 2 3AFY64556568

Page 42: Acs800 Optimal Ordering17102011

ACS800-U31 Type Code Sheet 10 - 125 HP, Wall MountedUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 3 1 ConstructionChannel

10…14 - SizeFrame Size R5 Frame Size R6

230V 0011 0016 0020 0040 00500025 0030 0060

500V 0020 0025 0030 0070 01000040 0050 0060 0120

690V 0060 0070(600V) 0100

15…16 - Voltage Rating2 = 230 V 5 = 500 V 7 = 690 V (600V)

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01

U31 = Wall mounted low harmonic drive (USA), IP21, With control panel CDP312R, RDCO-03, No EMC filter, Standard software (US), Cable conduit entry, Boards with coating, One set of default language documents.

���������� ���� ����������������

��������������������

ACS800-U31 - 1 3AFY64556568

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

1 or 2 Digital extensions1or 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

L516 available only with PMSM control

ACS800-U31 - 1 3AFY64556568

Page 43: Acs800 Optimal Ordering17102011

ACS800-U31 Type Code Sheet 10 - 125 HP, Wall MountedUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Control panel0J400 No control panel

Software compatibility with different option modules must be checked from ACS800 software compatibility (doc no. 3AFE64638211) in ABB Library.

ACS800-U31 - 2 3AFY64556568

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

CablingH357 Cable lead through entry (European)

Safety featuresQ967 Safe torque off STO, without safety relay

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Specialities

E202 not available for 690V units

Separate gate driver power supply board (ASTO) and connection wires included in the converter package. Does not include e.g. safety relay.

ACS800-U31 - 2 3AFY64556568

Page 44: Acs800 Optimal Ordering17102011

P904 Extended warranty

ACS800-U31 - 3 3AFY64556568 ACS800-U31 - 3 3AFY64556568

Page 45: Acs800 Optimal Ordering17102011

ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 1 7 ConstructionChannel

10…14 - Size

Frame Size R6 R7i R8i

400V 0060 0070 0140 0170 0210 0260 03200100 0390 0490

500V 0070 0100 0170 0210 0260 0320 04000120 0460 0510 0580

690V 0060 0070 0160 0200 0260 0320 04000100 0440 0540

15…16 - Voltage Rating3 = 400 V 5 = 500 V 7=690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard

L500 Analogue I/O extension RAIO-01

17 = Cabinet built regenerative drive, IP21 (UL type1), Main switch fuse with aR fuses, Line contactor (option for frame R6), 230 VAC control voltage, RDCO-03, Control Panel CDP312R, EMC 2nd Environment (R6 no EMC filter), Du/dt limitation by choke in 690V R8i, Common mode filter (not for R6), Standard software, Bottom entry and exit of cables, Cable lead through entry, Coated boards, One set of default language documents

Standard control supports

��������������������

���������� ���� ����������������

ACS800-17 (R6-R8i) - 1 3AFY64556568

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

L504 Additional I/O-Terminal Block

L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)

L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)

L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)

L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)

L515 I/O extension adapter

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

K453 Interbus-S adapter NIBA-01

K456 AF100 adapter NAFA-01

Standard control supports 3 Digital extensions and 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

I/O extension adapter adds three slots for I/O extension and Pulse encoder. Check compatibility with different control softwares.

N-type fieldbus adapters require DDCS Communication board.RDCO-03 included by default, L509 is optional

L516 available only with PMSM control

ACS800-17 (R6-R8i) - 1 3AFY64556568

Page 46: Acs800 Optimal Ordering17102011

ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Protection classB053 IP22 (UL type 1)

B054 IP42 (UL type 1)

B055 IP54 (UL type 12)

B059 IP54R

ConstructionC121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive

materials, requires marking of conductors (G338-G342)

Software compatibility with different option modules must be checked from ACS800 software compatibility (doc no. 3AFE64638211) in ABB Library.

ACS800-17 (R6-R8i) - 2 3AFY64556568

C121 Marine construction

C129 UL listed

C134 CSA approved

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, R6 only

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network, not available for 690V

E205 Du/dt limitation by choke (included in 690V R8i)

E206 Sine output filter

Line optionsF250 Line contactor (only for R6, included in other types)

CablingH351 Top entry (included with C129)

H353 Top exit (included with C129)

H350 Bottom entry (only with C129)

H352 Bottom exit (only with C129)

H356 DC cable connection busbars

H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)

H365 Cable conduit entry (US & UK version), brass 6 mm

Reinforced mechanics and fastening, door handels, self extinctive materials, requires marking of conductors (G338-G342)Not available with C129 or C134

Not available for R6 or with C121 or C129. Available output current reduced for some types

E202 in frames R7i and R8i requires a common motor terminal cubicle, adds width by 300mm (insert H359 to type code).

C129 includes: US type main switch fuse, Supply frequency 60 Hz, Top entry and exit,115VAC control voltage, US Cable conduit entry, all components UL listed/recognized, max. supply voltage 600 V.

C134 Includes: US/CSA type main switch fuse, Supply frequency 60 Hz, 115VAC control voltage, US Cable conduit entry, all components UL/CSA listed/recognized, max. supply voltage 600 V

E205 in frame R7i requires a common motor terminal cubicle, adds width by 300mm (insert H359 to type code).

H365 Cable conduit entry (US & UK version), brass 6 mm

H359 Common motor terminal cubicle Only with E202 in R7i/R8i or with E205 in R7i ACS800-17 (R6-R8i) - 2 3AFY64556568

Page 47: Acs800 Optimal Ordering17102011

ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

Control voltageG304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet optionsG300 Cabinet heater (External supply) (Not available with C134)

G313 Output for Motor heater (External supply)

G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)

G330 Halogen free wiring and materials (Not available with C129 or C134)

G338 Wire marking class A1

G339 Wire marking class A2

G340 Wire marking class A3

G341 Wire marking class B1

G342 Wire marking class C1

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Class A1, equipment pin numbers printed on conductors, conductors to terminal blocks not markedClass A2, equipment and terminal block pin numbers printed on conductorsClass A3, like A2 but marking by ringsClass B1, equipment and terminal block pin numbers and equipment Ids marked by ringsClass C1, like B1 but remote end address is also marked

ACS800-17 (R6-R8i) - 3 3AFY64556568

R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fanM600 1...1,6 A (1 pc)

M601 1,6...2,5 A (1 pc)

M602 2,5...4 A (1 pc)

M603 4...6,3 A (1 pc)

M604 6,3...10 A (1 pc) (not for R6)

M605 10...16 A (1 pc) (not for R6)

Safety featuresQ950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971

Q951 Emergency Stop, Category 0 with opening main contactor/breaker

Q952 Emergency Stop, Category 1 with opening main contactor/breaker

Q963 Emergency Stop, Category 0 without opening main contactor/breaker

Q964 Emergency Stop, Category 1 without opening main contactor/breaker

Q968 Safe torque off STO, with safety relay Not with Q950

Q954 Earth Fault Monitoring, Unearthed Mains

Q971 ATEX certified safety function Only with L513 and L514, not with Q950

SpecialitiesP902 Customised (Described in Technical appendix)

P904 Extended warranty

P913 Special colour (Described in Technical appendix)

Category 1 e-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or Permanent Magnet Control Std applicatrion (add +L501 to code)

Q951 and Q952 require contactor F250 for R6

ACS800-17 (R6-R8i) - 3 3AFY64556568

Page 48: Acs800 Optimal Ordering17102011

ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet builtUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 1 7 ConstructionChannel

10…14 - Size

Frame Size 2xR8i 3xR8i 4xR8i 6/5xR8i 6xR8i

400V 0640 0770 1070 1370 18100960

500V 0780 0870 1330 1640 21601140

690V 0790 0870 1330 1510 1980 2780 29401050

15…16 - Voltage Rating3 = 400 V 5 = 500 V 7=690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard

17 = Cabinet built regenerative drive, IP21 (UL type1), Air circuit breaker, aR fuses, 230 VAC control voltage, Control panel CDP312R, RDCO-03, EMC 2nd Environment, Du/dt limitation by choke, Common mode filter, Standard software, Bottom entry and exit of cables, Cable lead through entry, Coated boards, One set of default language documents

��������������������

���������� ���� ����������������

ACS800-17 (nxR8i) - 1 3AFY64556568

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

L504 Additional I/O-Terminal Block

L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)

L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)

L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)

L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)

L515 I/O extension adapter

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

K453 Interbus-S adapter NIBA-01

K456 AF100 adapter NAFA-01

Standard control supports 3 Digital extensions and 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

I/O extension adapter adds three slots for I/O extension and Pulse encoder. Check compatibility with different application softwares.

N-type fieldbus adapters require DDCS Communication board.RDCO-03 included by default, L509 is optional

L516 available only with PMSM control

��������������������

���������� ���� ����������������

ACS800-17 (nxR8i) - 1 3AFY64556568

Page 49: Acs800 Optimal Ordering17102011

ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet builtUpdated on 12 October 2011

Program

N687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Protection class

B053 IP22 (UL type 1)

B054 IP42 (UL type 1)

B055 IP54 (UL type 12)

B059 IP54R

Software compatibility with different option modules must be checked from ACS800 software compatibility (doc no. 3AFE64638211) in ABB Library.

ACS800-17 (nxR8i) - 2 3AFY64556568

B059 IP54R

Construction

C121 Marine construction

C129 UL listed

C134 CSA approved

FiltersE202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

E206 Sine output filter

Line optionsF259 Earthing switch (not available with C129)

Cabling

H351 Top entry (included with C129)

H353 Top exit (included with C129)

H350 Bottom entry (only with C129)

H352 Bottom exit (only with C129)

H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)

H365 Cable conduit entry (US & UK version), brass 6 mm

H359 Common motor terminal cubicle

Reinforced mechanics and fastening, door handels, self extinctive materials, requires marking of conductors (G338-G342)Not available with C129 or C134

C129 includes: Top entry and exit, Supply frequency 60 Hz, 115VAC control voltage, US Cable conduit entry, all components UL/CSA listed/recognized, max. supply voltage 600 V

EMC filter only for 0640-3, 0770-3, 0780-5 and 0870-5

Sine filter is not available with C121 or C129.

C134 includes: 115VAC control voltage, US Cable conduit entry, Supply frequency 60Hz, all components UL/CSA listed/recognized, max. supply voltage 600 V

ACS800-17 (nxR8i) - 2 3AFY64556568

Page 50: Acs800 Optimal Ordering17102011

ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet builtUpdated on 12 October 2011

Control voltage

G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet options

G300 Cabinet heater (External supply) (Not available with C134)

G313 Output for Motor heater (External supply)

G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)

G317 Busbar Supply Conductors

G330 Halogen free wiring and materials (Not available with C129 or C134)

G338 Wire marking class A1

G339 Wire marking class A2

G340 Wire marking class A3

G341 Wire marking class B1

G342 Wire marking class C1

Documentation language

R700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

Class A1, equipment pin numbers printed on conductors, conductors to terminal blocks not markedClass A2, equipment and terminal block pin numbers printed on conductorsClass A3, like A2 but marking by ringsClass B1, equipment and terminal block pin numbers and equipment Ids marked by ringsClass C1, like B1 but remote end address is also marked

ACS800-17 (nxR8i) - 3 3AFY64556568

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan

M602 2,5...4 A (1,2 or 4 pcs)

M603 4...6,3 A (1,2 or 4 pcs)

M604 6,3...10 A (1,2 or 4 pcs)

M605 10...16 A (1 or 2 pcs)

M606 17…25 A (1 pc)

Safety features

Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971

Q951 Emergency Stop, Category 0 with opening main contactor/breaker

Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)

Q963 Emergency Stop, Category 0 without opening main contactor/breaker

Q964 Emergency Stop, Category 1 without opening main contactor/breaker*)

Q968 Safe torque off STO, with safety relay Not with Q950

Q954 Earth Fault Monitoring, Unearthed Mains

Q971 ATEX certified safety function Only with L513 and L514, not with Q950

SpecialitiesP902 Customised (Described in Technical appendix)

P904 Extended warranty

P913 Special colour (Described in Technical appendix)

* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or Permanent Magnet Control Std applicatrion (add +L501 to code)

P913 Special colour (Described in Technical appendix)

ACS800-17 (nxR8i) - 3 3AFY64556568

Page 51: Acs800 Optimal Ordering17102011

ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 3 7 ConstructionChannel

10…14 - Size

Frame Size R6 R7i R8i

400V 0060 0070 0140 0170 0210 0260 03200100 0390 0510

500V 0070 0100 0170 0210 0260 0320 04000120 0460 0510 0610

690V 0060 0070 0170 0210 0260 0320 04000100 0440 0540

15…16 - Voltage Rating3 = 400 V 5 = 500 V 7=690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard

L500 Analogue I/O extension RAIO-01

37 = Cabinet built low harmonic drive, IP21 (UL type1), Main switch fuse with aR fuses, Line contactor (option for frame R6), 230 VAC control voltage, RDCO-03, Control Panel CDP312R, EMC 2nd Environment (R6 no EMC filter), Du/dt limitation by choke in 690V R8i, Common mode filter (not for R6), Standard software, Bottom entry and exit of cables, Cable lead through entry, Coated boards, One set of default language documents

Standard control supports 3 Digital extensions and

��������������������

���������� ���� ����������������

ACS800-37 (R6-R8i) - 1 3AFY64556568

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

L504 Additional I/O-Terminal Block

L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)

L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)

L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)

L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)

L515 I/O extension adapter

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

K453 Interbus-S adapter NIBA-01

K456 AF100 adapter NAFA-01

Standard control supports 3 Digital extensions and 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

I/O extension adapter adds three slots for I/O extension and Pulse encoder. Check compatibility with different application softwares.

N-type fieldbus adapters require DDCS Communication board.RDCO-03 included by default, L509 is optional

L516 available only with PMSM control

ACS800-37 (R6-R8i) - 1 3AFY64556568

Page 52: Acs800 Optimal Ordering17102011

ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

ProgramN687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Protection classB053 IP22 (UL type 1)

B054 IP42 (UL type 1)

B055 IP54 (UL type 12)

B059 IP54R

ConstructionC121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive

materials, requires marking of conductors (G338-G342)Not available with C129 or C134

Software compatibility with different option modules must be checked from ACS800 software compatibility (doc no. 3AFE64638211) in ABB Library.

ACS800-37 (R6-R8i) - 2 3AFY64556568

C129 UL listed

C134 CSA approved

FiltersE200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, R6 only

E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network, not available for 690V

E205 Du/dt limitation by choke (included in 690V R8i)

E206 Sine output filter

Resistor brakingD150 Braking chopper

D151 Braking resistor

Line optionsF250 Line contactor (only for R6, included in other types)

CablingH351 Top entry (included with C129)

H353 Top exit (included with C129)

H350 Bottom entry (only with C129)

H352 Bottom exit (only with C129)

H356 DC cable connection busbars

H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)

H365 Cable conduit entry (US & UK version), brass 6 mm

Not available for R6, or with C121 , C129, D150 or D151. Available output current reduced for some types

Braking resistor is not available as IP54, IP54R, or with C121 , C129 or E206. Available output current reduced for some types

C129 includes: US type main switch fuse, Supply frequency 60 Hz, Top entry and exit,115VAC control voltage, US Cable conduit entry, all

C134 Includes: US/CSA type main switch fuse, Supply frequency 60 Hz 115VAC control voltage, US Cable conduit entry, all components UL/CSA

materials, requires marking of conductors (G338-G342)Not available with C129 or C134

E202 in frames R7i and R8i requires a common motor terminal cubicle, adds width by 300mm (insert H359 to type code).

E205 in frame R7i requires a common motor terminal cubicle, adds width by 300mm (insert H359 to type code).

H359 Common motor terminal cubicle Only with E202 in R7i/R8i or with E205 in R7i ACS800-37 (R6-R8i) - 2 3AFY64556568

Page 53: Acs800 Optimal Ordering17102011

ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet builtUpdated on 12 October 2011

Control voltage

G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet optionsG300 Cabinet heater (External supply) (Not available with C134)

G313 Output for Motor heater (External supply)

G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)

G330 Halogen free wiring and materials (Not available with C129 or C134)

G338 Wire marking class A1

G339 Wire marking class A2

G340 Wire marking class A3

G341 Wire marking class B1

G342 Wire marking class C1

Documentation languageR700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

Class A1, equipment pin numbers printed on conductors, conductors to terminal blocks not markedClass A2, equipment and terminal block pin numbers printed on conductorsClass A3, like A2 but marking by ringsClass B1, equipment and terminal block pin numbers and equipment Ids marked by ringsClass C1, like B1 but remote end address is also marked

ACS800-37 (R6-R8i) - 3 3AFY64556568

R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fanM600 1...1,6 A (1 pc)

M601 1,6...2,5 A (1 pc)

M602 2,5...4 A (1 pc)

M603 4...6,3 A (1 pc)

M604 6,3...10 A (1 pc) (not for R6)

M605 10...16 A (1 pc) (not for R6)

Safety featuresQ950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971

Q951 Emergency Stop, Category 0 with opening main contactor/breaker

Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)

Q963 Emergency Stop, Category 0 without opening main contactor/breaker

Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)

Q968 Safe torque off STO, with safety relay Not with Q950

Q954 Earth Fault Monitoring, Unearthed Mains

Q971 ATEX certified safety function Only with L513 and L514, not with Q950

SpecialitiesP902 Customised (Described in Technical appendix)

P904 Extended warranty

P913 Special colour (Described in Technical appendix)

* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or Permanent Magnet Control Std applicatrion (add +L501 to code)

Q951 and Q952 require contactor F250 for R6

ACS800-37 (R6-R8i) - 3 3AFY64556568

Page 54: Acs800 Optimal Ordering17102011

ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet builtUpdated on 12 October 2011

1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 3 7 ConstructionChannel

10…14 - Size

Frame Size 2xR8i 3xR8i 4xR8i 6/5xR8i 6xR8i

400V 0640 0770 1070 1430 18100960

500V 0780 0870 1330 1820 22001160

690V 0790 0870 1330 1510 2320 2780 33101160

15…16 - Voltage Rating3 = 400 V 5 = 500 V 7=690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard

37 = Cabinet built low harmonic drive, IP21 (UL type1), Air circuit breaker, aR fuses, 230 VAC control voltage, Control panel CDP312R, RDCO-03, EMC 2nd Environment, Du/dt limitation by choke, Common mode filter, Standard software, Bottom entry and exit of cables, Cable lead through entry, Coated boards, One set of default language documents

��������������������

���������� ���� ����������������

ACS800-37 (nxR8i) - 1 3AFY64556568

L500 Analogue I/O extension RAIO-01

L501 Digital I/O extension RDIO-01

L502 Pulse encoder interface RTAC-01

L516 Resolver interface RRIA-01

L509 DDCS Communication 2 RDCO-02

L508 DDCS Communication 1 RDCO-01

L504 Additional I/O-Terminal Block

L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)

L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)

L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)

L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)

L515 I/O extension adapter

Fieldbus 2 slots available for I/O options or Fieldbus adapters

K451 DeviceNet adapter RDNA-01

K452 LONWorks adapter RLON-01

K454 Profibus-DP adapter RPBA-01

K457 CANOpen adapter RCAN-01

K458 Modbus adapter RMBA-01

K462 ControlNet adapter RCNA-01

K466 Ethernet adapter(EIP,MB/TCP) RETA-01

K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

K453 Interbus-S adapter NIBA-01

K456 AF100 adapter NAFA-01

Standard control supports 3 Digital extensions and 2 Analogue extensions, one for I/O, the other only for motor temp. measurement Communication board has always one dedicated slot.Modbus adapter can be used with other Fieldbus adapter

I/O extension adapter adds three slots for I/O extension and Pulse encoder. Check compatibility with different application softwares.

N-type fieldbus adapters require DDCS Communication board.RDCO-03 included by default, L509 is optional

L516 available only with PMSM control

��������������������

���������� ���� ����������������

ACS800-37 (nxR8i) - 1 3AFY64556568

Page 55: Acs800 Optimal Ordering17102011

ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet builtUpdated on 12 October 2011

Program

N687 Pump control

N651 Master/follower control

N652 Crane drive control

N653 Application base control Available only for Drives Engineering Centers

N655 PCP and ESP control

N660 Inline control

N661 Winder control

N669 Centrifuge control Decanter control requires DDCS communication + optic fibres

N671 System control

N675 Rod pump control

N677 PMSM control - system interface (for low speed-high torque motors)

N679 PMSM control - standard interface (for low speed-high torque motors)

N682 Multiblock control

N697 Crane control

N698 Winch control

N678 Test bench control

Protection class

B053 IP22 (UL type 1)

B054 IP42 (UL type 1)

B055 IP54 (UL type 12)

B059 IP54R

Program compatibility with different option modules must be checked from ACS800 software compatibility (doc no. 3AFE64638211) in ABB Library.

ACS800-37 (nxR8i) - 2 3AFY64556568

B059 IP54R

Construction

C121 Marine construction

C129 UL listed

C134 CSA approved

FiltersE202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

E206 Sine output filter

Resistor braking (standard option only for 2xR8i)

D150 Braking chopper

D151 Braking resistor

Line optionsF259 Earthing switch (not available with C129)

Cabling

H351 Top entry (included with C129)

H353 Top exit (included with C129)

H350 Bottom entry (only with C129)

H352 Bottom exit (only with C129)

H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)

H365 Cable conduit entry (US & UK version), brass 6 mm

Reinforced mechanics and fastening, door handels, self extinctive materials, requires marking of conductors (G338-G342)Not available with C129 or C134

EMC filter only for 0640-3, 0770-3, 0780-5 and 0870-5

Braking resistor is not available as IP54, IP54R, with C129 or E206. Marine construction C121 available only for 500V and 690V.Available output current reduced for some types

Sine filter is not available with �����������������������.

C129 includes: Top entry and exit,115VAC control voltage, Supply frequency 60 Hz, US Cable conduit entry, all components UL/CSA listed/recognized, max. supply voltage 600 V

C134 includes: 115VAC control voltage, US Cable conduit entry, Supply frequency 60Hz, all components UL/CSA listed/recognized, max. supply voltage 600 V

H359 Common motor terminal cubicleACS800-37 (nxR8i) - 2 3AFY64556568

Page 56: Acs800 Optimal Ordering17102011

ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet builtUpdated on 12 October 2011

Control voltage

G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet options

G300 Cabinet heater (External supply) (Not available with C134)

G313 Output for Motor heater (External supply)

G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)

G317 Busbar Supply Conductors

G330 Halogen free wiring and materials (Not available with C129 or C134)

G338 Wire marking class A1

G339 Wire marking class A2

G340 Wire marking class A3

G341 Wire marking class B1

G342 Wire marking class C1

Documentation language

R700 English

R701 German Delivered set may include manuals in English

R702 Italian Delivered set may include manuals in English

R703 Dutch Delivered set may include manuals in English

R704 Danish Delivered set may include manuals in English

R705 Swedish Delivered set may include manuals in English

R706 Finnish Delivered set may include manuals in English

R707 French Delivered set may include manuals in English

Class A1, equipment pin numbers printed on conductors, conductors to terminal blocks not markedClass A2, equipment and terminal block pin numbers printed on conductorsClass A3, like A2 but marking by ringsClass B1, equipment and terminal block pin numbers and equipment Ids marked by ringsClass C1, like B1 but remote end address is also marked

ACS800-37 (nxR8i) - 3 3AFY64556568

R707 French Delivered set may include manuals in English

R708 Spanish Delivered set may include manuals in English

R709 Portuguese (in Portugal) Delivered set may include manuals in English

R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan

M602 2,5...4 A (1,2 or 4 pcs)

M603 4...6,3 A (1,2 or 4 pcs)

M604 6,3...10 A (1,2 or 4 pcs)

M605 10...16 A (1 or 2 pcs)

M606 17…25 A (1 pc)

Safety features

Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971

Q951 Emergency Stop, Category 0 with opening main contactor/breaker

Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)

Q963 Emergency Stop, Category 0 without opening main contactor/breaker

Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)

Q968 Safe torque off STO, with safety relay Not with Q950

Q954 Earth Fault Monitoring, Unearthed Mains

Q971 ATEX certified safety function Only with L513 and L514, not with Q950

SpecialitiesP902 Customised (Described in Technical appendix)

P904 Extended warranty

P913 Special colour (Described in Technical appendix)

* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or Permanent Magnet Control Std applicatrion (add +L501 to code)

ACS800-37 (nxR8i) - 3 3AFY64556568

Page 57: Acs800 Optimal Ordering17102011

ABB Oy, Drives Technical Appendix for ACS800-x7Revision:

ABB Company: Date: Page:Your ref: End Customer:Contact Person: Project Title:Phone / Fax: Application:eMail: Customer ref:

ACS800-07/-17/-37 Non-Standard Options in ACS 800 Price ListAll options below needs also +P902 option

No engineering needed only standard as build drawings with customer specific drawing title blocks (specify above project title, end customer and customer ref) no additional engineeringDocument approval not needed, send them just for information before starting the production

Supply freq. for options 60Hz (default 50Hz) Signal lamps (specify colours pcs: and function)

Power for RMIO board from internal Additional relays (specify type pcs:230 VAC (Only for ACS800-07, R6-R8) and function)Ammeter AI/O galvanic isolation for mA signal (1-4 pcs)Voltmeter Running hour meter Customer specific cable lead through (gland) plate

(specify below)+P913 Special colour RAL Empty cabinet (specify on separate page)

NAMUR I/O, requires also +H366 Internal parallel connection busbars for 2xR8i and 3xR8i+F250+Q951+L501+K454+P902

+C164 Plinth for the cabinet, height: 100mm+C130 Air outlet channel (IPxxR) 200mm

+D150 Braking chopper (NBRA-6X9) (3-6xR8i)+C128 Air inlet through bottom +D151 Braking resistor (SAFUR) (3-6xR8i)

3 phase braking chopper (ACS800-607)Bypass, specify on page "Bypass" (specify the braking power)

�+Q965 SLS with encoder�+Q966 SLS without encoder

Design by the old reference project. FIDRI No.: or Purchace No.:Detailed description of desired function:

Other informationCustomer/Local ABB delivers components to FIDRI and sends the Data Sheets of the components with Technical Appendix. (min. 9weeks before loading date)

Customer/Local ABB delivers predesign documentation

Special door labels (specify using separate appendix)

Preliminary documentation required: Delivery time must be agreed with FIDRI Area Manager

Dimension drawings By Lotus Notes

Control circuit diagrams

Delivery of final documentation By Lotus Notes

Company

Attention Phone

Country e-mail

Address TechnApp - 1 3AFY64556568

Page 58: Acs800 Optimal Ordering17102011

ABB Oy, Drives Technical Appendix for ACS800-x7 with BypassRevision:

ABB Company: Date: Page:Your ref: End Customer:Contact Person: Project Title:Phone / Fax: Application:eMail: Customer ref:

ACS800-07/-17/-37 Engineered DOL Bypass

Please specify nominal motor power (P), full load current (FLC) in the direct on line (DOL) supply:

Nominal power: kW

Full load current: A

Network voltage: VAC

Options required also:

+G307 (Terminals for External Control Voltage)

+P902 (Customized)

Protections for the motor included in the SACE Tmax PR222MP as standard

Adjustable protection against overload, rotor block, short-circuit and missing phase or unbalanced

Ground leakage protection in earthed networks as an option (please select if required).

Ground leakage monitoring by sum current transformer and monitoring relay

Change over control

Manual Local

External

Automatic Synchronization

Please note:

Engineered DOL bypass not for +C129 (UL listed) ; +C134 (CSA approved) nor +E202 (EMC/RFI-filter)

Additional information:

Page 59: Acs800 Optimal Ordering17102011

ABB Oy, Drives Technical Appendix for ACS800-x7Empty cabinets

ABB Company: Date: Page:Your ref: End Customer:Contact Person: Project Title:Phone / Fax: Application:Email:

Number of empty cabinets

ColourRAL 7035 (std.) Special

Mounting

Mounted to the frequency converter Stand-alone

On the left side of the frequency converter (front view)

On the right side of the frequency converter (front view)

Enclosure

IP21 Normal door with air inlet openings

IP22 Normal door with control panel mounting platform

IP42 Blank door and roof & no air inlet openings

IP54 (no cooling fans)

IP54R (outlet connection to ventilation channel)

Cable lead through (for empty cabinet)Standard cable lead through No need for cable lead through

(sealed roof and bottom)

Top Cable gland plate 6mm brass (undrilled)Cable gland plate 3mm steel (undrilled)

Bottom Cable gland plate 3mm aluminium (undrilled)

Cabinet width300mm 700 mm

400 mm 800 mm

600 mm 1000 mm

Assembly plates on both sides and on back as standard

Additional information:

TechnApp - 1 3AFY64556568

Page 60: Acs800 Optimal Ordering17102011

ABB Oy, Drives Technical Appendix for ACS800-x7Labels

ABB Company: Date: Page:Your ref: End Customer:Contact Person: Project Title:Phone / Fax: Application:eMail:

Labels described in this specification are not included as standard only with option +P902. Models A and B are factory preferred types. If location of labels is not specified, standard location willbe used. Specify location using the lay-out drawing.

Rivet mounting Customer delivers own door labels

Stick-on label Customer defined labelsSpecify:label size

Factory preferred typescharacter height

A Main reference labelsize 140 x 33 mm characters per lineChar. height 20 mmMax 5 characters

B Description labelsize 140 x 33 mm Char. height 6 mm23 char. per line , max 3 lines

C Apparatus label52 x 13 mm Char. height 3,5 mm17 char. per line, max 2 linesStandard location is about 12 mm below the apparatus

Model pcs.Sign text Location

TechnApp - 1 3AFY64556568