ACOUSTIC CURRENT DOPPLER PROFILERS (ADCP’s). ADCP’s Developing Standards for ADCP’s. PI: Michael Winkler (CHL). Problem: - PowerPoint PPT PresentationTRANSCRIPT
Research and DevelopmentUS Army Corpsof Engineers
ACOUSTIC CURRENT DOPPLER PROFILERS (ADCP’s)
Research and DevelopmentUS Army Corpsof Engineers
ADCP’s Developing Standards for ADCP’s
Problem: Currently there is not a Corps Standard for the use of ADCP’s for Discharge measurements or for velocity and current direction data. This data is used extensively throughout the Corps of Engineers for creating and developing Stage Discharge Curves to Validating Numerical and Physical Models. .
Products:•Corps Guidance on using an ADCP for a Discharge MeasurementCorps Guidance on using an ADCP for a Discharge Measurement•Corps Recommendations on Software and Firmware Versions for ADCP’sCorps Recommendations on Software and Firmware Versions for ADCP’s•Corps Guidance on Data Review of ADCP dataCorps Guidance on Data Review of ADCP data
Benefits:•Establishment of a formal Co-Op between the Corps and the USGSEstablishment of a formal Co-Op between the Corps and the USGS•Establishment of a Contact Spec for ReferenceEstablishment of a Contact Spec for Reference•Better overall data quality and integrityBetter overall data quality and integrity
Problem: Currently there is not a Corps Standard for the use of ADCP’s for Discharge measurements or for velocity and current direction data. This data is used extensively throughout the Corps of Engineers for creating and developing Stage Discharge Curves to Validating Numerical and Physical Models. .
Products:•Corps Guidance on using an ADCP for a Discharge MeasurementCorps Guidance on using an ADCP for a Discharge Measurement•Corps Recommendations on Software and Firmware Versions for ADCP’sCorps Recommendations on Software and Firmware Versions for ADCP’s•Corps Guidance on Data Review of ADCP dataCorps Guidance on Data Review of ADCP data
Benefits:•Establishment of a formal Co-Op between the Corps and the USGSEstablishment of a formal Co-Op between the Corps and the USGS•Establishment of a Contact Spec for ReferenceEstablishment of a Contact Spec for Reference•Better overall data quality and integrityBetter overall data quality and integrity
PI: Michael Winkler (CHL)
Research and DevelopmentUS Army Corpsof Engineers
ADCP’s Developing Standards for ADCP’s
• TELEDYNE RD INSTRUMENTS
• Rio Grande
– Broadband
– 4 Transducers
– Affordable
– High Resolution Profiling
– Exceptionally Small - Easy to Handle - Mounting Options
• TELEDYNE RD INSTRUMENTS
• Rio Grande
– Broadband
– 4 Transducers
– Affordable
– High Resolution Profiling
– Exceptionally Small - Easy to Handle - Mounting Options 600 or 1200 kHz600 or 1200 kHz
Research and DevelopmentUS Army Corpsof Engineers
ADCP’s Developing Standards for ADCP’s
• SonTek-YSI
• River Surveyor
– Narrowband
– 3 Transducers
– Affordable
– Exceptionally Small - Easy to Handle - Mounting Options
• SonTek-YSI
• River Surveyor
– Narrowband
– 3 Transducers
– Affordable
– Exceptionally Small - Easy to Handle - Mounting Options
Research and DevelopmentUS Army Corpsof Engineers
Depth Cell
ADCP Conventional current meter
Research and DevelopmentUS Army Corpsof Engineers
ADCP’s Developing Standards for ADCP’s
Research and DevelopmentUS Army Corpsof Engineers
ADCP Discharge Measurement
TRANSECT PATHACROSS STREAM
QN
VW
VB
Research and DevelopmentUS Army Corpsof Engineers
Measured and Unmeasured Areas
Shore estimate
Shore estimate
Top estimate
Bottom estimate
Measured
Research and DevelopmentUS Army Corpsof Engineers
Distance = 3m
Depth0.2
0.2
0.1
Discharge Measurement
Q ENSEMBLE = 1.5 m3/s
Q = 1.5 m3/s
Research and DevelopmentUS Army Corpsof Engineers
Distance = 9m
Depth
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3
Q ENSEMBLE = 4.2 m3/s
Q = 5.7 m3/s
Research and DevelopmentUS Army Corpsof Engineers
Distance = 15m
Depth
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3 0.4
0.4 0.5
0.4 0.5
0.40.3
0.3
0.2
0.3
0.5
Q ENSEMBLE = 12.3 m3/s
Q = 18 m3/s
Research and DevelopmentUS Army Corpsof Engineers
Distance = 21m
Depth
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3 0.4
0.4 0.5
0.4 0.5
0.40.3
0.3
0.2
0.3
0.5 0.6 0.7
0.6 0.6
0.60.5
0.50.4
0.40.3
0.30.2
Q ENSEMBLE = 17.1 m3/s
Q = 35.1 m3/s
Research and DevelopmentUS Army Corpsof Engineers
Distance = 27m
Depth
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3 0.4
0.4 0.5
0.4 0.5
0.40.3
0.3
0.2
0.3
0.5 0.6 0.7
0.6 0.6
0.60.5
0.50.4
0.40.3
0.30.2
0.8 0.8
0.8 0.8
0.70.7
0.50.5
0.40.4
0.30.3
0.2 Q ENSEMBLE = 21.6 m3/s
Q = 56.7 m3/s
Research and DevelopmentUS Army Corpsof Engineers
ADCP Survey John Day
John DayJohn Day
Columbia RiverColumbia River
1228’ Spillway1228’ Spillway
20 Gates20 Gates
Waves 3’ to 6’Waves 3’ to 6’
Research and DevelopmentUS Army Corpsof Engineers
HOMOGENEOUS NONHOMOGENEOUS
Flow Homogeneity
Research and DevelopmentUS Army Corpsof Engineers
ADCP Survey John Day
Research and DevelopmentUS Army Corpsof Engineers
Distance = 33m
Depth
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3 0.4
0.4 0.5
0.4 0.5
0.40.3
0.3
0.2
0.3
0.5 0.6 0.7
0.6 0.6
0.60.5
0.50.4
0.40.3
0.30.2
0.8 0.8
0.8 0.8
0.70.7
0.50.54
0.40.4
0.30.3
0.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2 Q ENSEMBLE = 28.2 m3/s
Q = 84.9 m3/s
Research and DevelopmentUS Army Corpsof Engineers
Distance = 39m
Depth
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3 0.4
0.4 0.5
0.4 0.5
0.40.3
0.3
0.2
0.3
0.5 0.6 0.7
0.6 0.6
0.60.5
0.50.4
0.40.3
0.30.2
0.8 0.8
0.8 0.8
0.70.7
0.50.5
0.40.4
0.30.3
0.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2 Q ENSEMBLE = 28.2 m3/s
Q = 113.1 m3/s
Research and DevelopmentUS Army Corpsof Engineers
Distance = 45m
Depth
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3 0.4
0.4 0.5
0.4 0.5
0.40.3
0.3
0.2
0.3
0.5 0.6 0.7
0.6 0.6
0.60.5
0.50.4
0.40.3
0.30.2
0.8 0.8
0.8 0.8
0.70.7
0.50.5
0.40.4
0.30.3
0.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2
0.9
0.8
0.8
0.6
0.5
0.4
0.2
0.8
0.8
0.7
0.5
0.4
Q ENSEMBLE = 23.1 m3/s
Q = 136.2 m3/s
Research and DevelopmentUS Army Corpsof Engineers
Distance = 51m
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3 0.4
0.4 0.5
0.4 0.5
0.40.3
0.3
0.2
0.3
0.5 0.6 0.7
0.6 0.6
0.60.5
0.50.4
0.40.3
0.30.2
0.8 0.8
0.8 0.8
0.70.7
0.50.5
0.40.4
0.30.3
0.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2
0.9
0.8
0.8
0.6
0.5
0.4
0.2
0.8
0.8
0.7
0.5
0.4
0.7
0.7
0.6
0.4
0.3
0.6
0.4
0.3
0.2
Q ENSEMBLE = 13.2 m3/s
Q = 149.4 m3/s
Research and DevelopmentUS Army Corpsof Engineers
Distance = 57m
Discharge Measurement
0.2
0.2
0.1
0.3
0.3
0.3
0.2
0.3 0.4
0.4 0.5
0.4 0.5
0.40.3
0.3
0.2
0.3
0.5 0.6 0.7
0.6 0.6
0.60.5
0.50.4
0.40.3
0.30.2
0.8 0.8
0.8 0.8
0.70.7
0.50.5
0.40.4
0.30.3
0.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2
1.0 1.0
1.0
0.9
1.0
0.9
0.70.7
0.50.5
0.40.4
0.20.2
0.9
0.8
0.8
0.6
0.5
0.4
0.2
0.8
0.8
0.7
0.5
0.4
0.7
0.7
0.6
0.4
0.3
0.6
0.4
0.3
0.2
0.4
0.3
0.2
0.2
0.1
Q ENSEMBLE = 3.6 m3/s
Q = 153 m3/s
Research and DevelopmentUS Army Corpsof Engineers
ADCP’s Developing Standards for ADCP’s
X-Coord
Y-C
oo
rd
1031500 1032000 1032500
323000
323500
324000
Line 4
1 ft/s
Research and DevelopmentUS Army Corpsof Engineers
Questions?
Teledyne RDI SonTek YSI
USGS