SS-DACNF www.daikincomfort.com 4/19 Supersedes 1/16
■ Product Features• Check flowrater for heat pump and
cooling-only applications• All-Aluminum tube/aluminum fin coil• Direct-drive, resilient-mount, multi-speed motor• Sequence-controlled and rust-resistant
nickel chromium heating elements of 5, 6, 8 and 10 kW
• High-efficiency evaporator coil• Quiet operation • Models with EEM motors:
ACNF25 & ACNF31
• Models with PSC motors: ACNF18, ACNF24, & ACNF30
• Available with and without heat• AHRI Certified; ETL Listed• Primary/secondary drain connection
in a high-temperature plastic drain pan• Suitable for free-return installation
(non-ducted return air)• Galvanized-steel construction• Factory-installed pull-type disconnect • Easy service access
■ ContentsNomenclature .........................................2Product Specifications ............................3Dimensions .............................................6Airflow Data ............................................7Heat Kit Data ............................................7Wiring Diagram .......................................8Accessories ...........................................12
* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.
ACNF Series
Ceiling-Mounted Air Handlers1½ to 2½ Tons
2 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 3
A C N F 24 05 1 6 AA 1 2 3 4 5,6 7,8 9 10 11,12
Brand Engineering *A -‐ Single-‐Piece Air Handler Major/ Minor Revisions
*Not used for inventory management
Unit ApplicationC -‐ Ceiling Mount Units Refrigerant
6 = R-‐410A or R-‐22Cabinet FinishN -‐ Uncased Electrical
1 -‐ 208/240 V, 1 Phase, 60 HzExpansion DeviceF -‐ Flowrater Heater Kit
00 = No Heat 06 = 6 kWNominal Capacity Range 03 = 3 kW 08 = 8 kW18 = 1½ Tons (PSC Motor) 25 = 2 Tons (EEM Motor) 05 = 5 kW 10 = 10 kW24 = 2 Tons (PSC Motor) 31 = 2½ Tons (EEM Motor)30 = 2½ Tons (PSC Motor)
Nomenclature
2 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 3
ACNF18001
ACNF18051
ACNF18061
ACNF18081
ACNF24001
ACNF24051
ACNF24061
ACNF24081
Performance Ratings
Cooling (BTU/h) 18,000 18,000 18,000 18,000 24,000 24,000 24,000 24,000
Piston Size² 0.051 0.051 0.051 0.051 0.057 0.057 0.057 0.057
Blower
Diameter 5.75 5.75 5.75 5.75 6.31 6.31 6.31 6.31
Width 6.75 6.75 6.75 6.75 8.25 8.25 8.25 8.25
Coil Drain Connect FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
Blower Motor
FLA 0.72 0.72 0.72 0.72 1.34 1.34 1.34 1.34
HP 1/8 1/8 1/8 1/8 1/4 1/4 1/4 1/4
Refrigerant Line Connection Size
Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Min Circuit Ampacity @ 230V 0.9 27 33.5 40.6 1.68 27.8 34.3 41.3
Min Circuit Ampacity @ 208V 0.9 23.5 29.2 35.3 1.68 24.3 29.9 36.1
Max. Overcurrent Device @ 230V 15 30 35 45 15 30 35 45
Max. Overcurrent Device @ 208V 15 25 30 40 15 25 30 40
Minimum Voltage VAC 197 197 197 197 197 197 197 197
Maximum Voltage VAC 253 253 253 253 253 253 253 253
Electric HeatkW @ 230 Volts 0.0 4.8 6.0 7.3 0.0 4.8 6.0 7.3
BTU/h @ 230 Volts 0 16,400 20,500 24,900 0 16,400 20,500 24,900
Ship Weight (lbs) 59 59 59 59 69 69 69 69
¹ CFM @.3 static ²Shipped with Coil
Notes• For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana® outdoor unit.
• When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. When matching the “AC” unit that has elec-tric heat with a heat pump, order “HEAT PUMP SHUT OFF KIT HPSK-01.” The ACXX-00 units do not require this kit.
Product Specifications
4 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 5
ACNF24101
ACNF250016
ACNF250516
ACNF250616
ACNF250816
ACNF251016
ACNF30001
ACNF30051
Performance Ratings
Cooling (BTU/h) 24,000 24,000 24,000 24,000 24,000 24,000 30,000 30,000
Piston Size² 0.057 0.055 0.055 0.055 0.055 0.055 0.061 0.061
Blower
Diameter 6.31 6.31 6.31 6.31 6.31 6.31 6.75 6.75
Width 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25
Coil Drain Connect FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
Blower Motor
FLA 1.34 2 2 2 2 2 1.34 1.34
HP 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Refrigerant Line Connection Size
Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Min Circuit Ampacity @ 230V 54.9 2.5 28.6 35.1 42.2 55.8 1.68 27.8
Min Circuit Ampacity @ 208V 47.8 2.5 26.1 32.0 38.4 50.7 1.68 24.3
Max. Overcurrent Device @ 230V 60 15 30 40 45 60 15 30
Max. Overcurrent Device @ 208V 50 15 30 35 40 60 15 25
Minimum Voltage VAC 197 197 197 197 197 197 197 197
Maximum Voltage VAC 253 253 253 253 253 253 253 253
Electric Heat
kW @ 230 Volts 9.8 0.0 4.8 6.0 7.3 9.8 0.0 4.8
BTU/h @ 230 Volts 33,500 0 16,400 20,500 24,900 33,500 0 16,400
Ship Weight (lbs) 69 69 69 69 69 69 79 79
¹ CFM @ .2 static
Note: When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. When matching the “AC” unit that has electric heat with a heat pump, order “HEAT PUMP SHUT OFF KIT HPSK-01.” The ACXX-00 units do not require this kit.
Product Specifications
4 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 5
Product Specifications
ACNF30061
ACNF30081
ACNF30101
ACNF310016
ACNF310516
ACNF310616
ACNF310816
ACNF311016
Performance Ratings
Cooling (BTU/h) 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000
Piston Size² 0.061 0.061 0.061 0.059 0.059 0.059 0.059 0.059
Blower
Diameter 6.75 6.75 6.75 6.75 6.75 6.75 6.75 6.75
Width 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25
Coil Drain Connect FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
Blower Motor
FLA 1.34 1.34 1.34 2 2 2 2 2
HP 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Refrigerant Line Connection Size
Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Min Circuit Ampacity @ 230V 34.3 41.3 54.9 2.5 28.6 35.1 42.2 55.8
Min Circuit Ampacity @ 208V 29.9 36.1 47.8 2.5 26.1 32.0 38.4 50.7
Max. Overcurrent Device @ 230V 35 45 60 15 30 40 45 60
Max. Overcurrent Device @ 208V 30 40 50 15 30 35 40 60
Minimum Voltage VAC 197 197 197 197 197 197 197 197
Maximum Voltage VAC 253 253 253 253 253 253 253 253
Electric Heat
kW @ 230 Volts 6.0 7.3 9.8 0.0 4.8 6.0 7.3 9.8
BTU/h @ 230 Volts 20,500 24,900 33,500 0 16,400 20,500 24,900 33,500
Ship Weight (lbs) 79 79 79 79 79 79 79 79
¹ CFM @ .2 static
Note: When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. When matching the “AC” unit that has electric heat with a heat pump, order “HEAT PUMP SHUT OFF KIT HPSK-01.” The ACXX-00 units do not require this kit.
6 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 7
A
B
2⅜
11¼4⅜
4⅝
10
21
1
3/4
D
C
ELECT. HEATERLOCATION
FRONT VIEW
TOP VIEW
SUCTION LINE
CONTROL BOX
THIS END:SUPPLY VOLTAGEWIRINGOPPOSITE END:LOW VOLTAGEWIRING
LIQUID LINE
PLASTICDRIN PAN
PRIMARY DRAIN3/4" FEMALE NPT
SECONDARY DRAIN3/4" FEMALE NPT
Dimensions
ACNF18 ACNF24 ACNF25 ACNF30 ACNF31
A 37¼" 43¼” 43¼” 49¼” 49¼”
B 34¾” 40¾” 40¾” 46¾” 46¾”
C 30” 36” 36” 42" 42"
D 6½” 6½” 6½” 6½” 6½”
6 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 7
Airflow Data
Heating Capacity/kW Correction Factor
Supply Voltage 240 230 220 210 208
Correction Factor 1.08 1.00 0.92 0.84 0.82
(Multiply the 230-volt capacity by factors)
Model Motor Speed
CFM delivered against External Static Pressure
0.1” 0.2” 0.3” 0.4” 0.5”
ACNF18****High 710 660 590 515 435
Low 650 595 540 480 390
ACNF24****High 955 880 820 740 675
Low 885 840 775 725 620
ACNF25****
T5 969 912 854 798 778
T4 969 912 854 798 778
T3 802 776 690 641 584
T2 680 610 550 484 431
T1 680 610 550 484 431
ACNF30****High 1,075 1,005 920 820 730
Low 945 890 835 760 650
ACNF31****
T5 999 928 868 824 764
T4 999 928 868 824 764
T3 871 798 750 687 614
T2 763 695 625 548 478
T1 763 695 625 548 478
Note: Airflow data for 240 Vac with dry coil and no filter in place.
8 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 9
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
W
arni
ngHi
gh V
olta
ge:
Dis
conn
ect
all
pow
er b
efor
e se
rvic
ing
or i
nsta
lling
thi
s un
it. M
ultip
le p
ower
so
urce
s m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r dea
th.⚡
Wiring Diagram — ACNF18/ 24/ 30
COLO
R CO
DEW
H
WHI
TEGR
GREE
NBK
BLA
CKPU
PUR
PLE
RD
R
EDBR
BRO
WN
YL BL
LOW
VOL
TAGE
HIGH
VOL
TAGE
FIEL
D W
IRIN
G
HIGH
VOL
TAGE
FACT
ORY
WIR
ING
WIR
E CO
DE
LOW
VOL
TAGE
NOT
E 2
EBTD
R
ELEC
TRON
IC B
LOW
ER T
IME
DELA
Y RE
LAY
EM
EVA
PORA
TOR
MOTO
RDI
SC
DIS
CONN
ECT
SWIT
CH
COMP
ONEN
T CO
DE
DISC
DISC
208/2
40 V
OLTS
HTR1
TLL2
T2
240V
208V
C
FCLO
HI
TR
24V
RD
EBTD
R
HC
GRW
HBL
EM
EBTD
R
COM
NCNO
HTR2
TL
2) S
EE C
OMPO
SITE
WIR
ING
DIAG
RAMS
IN IN
STAL
LATI
ON IN
STRU
CTIO
NSFO
R PR
OPER
LOW
VOL
TAGE
WIR
ING
CON
NECT
IONS
. USE
N.E
.C. C
LASS
2 W
IRE.
NOTE
S:1)
TO
PLAC
E UN
IT IN
LOW
SPE
ED, R
EMOV
E BL
ACK
MOTO
R LE
AD F
ROM
ELEC
TRON
IC B
LOW
ER T
IME
DELA
Y RE
LAY
(E
BTDR
) COM
TER
MINA
L AND
REP
LACE
WIT
H RE
D MO
TOR
LEAD
.
BR
FL FL
3) A
STER
ISK
(*) IN
DICA
TES
THAT
HEA
TING
ELE
MENT
, THE
RMAL
LIMI
T&
INTE
RCON
NECT
ING
WIR
ES O
F HE
ATER
#2
ARE
DELE
TED
WIT
H SI
NGLE
HEA
TING
ELE
MENT
UNI
TS.
**
REB
TDR
CG
4) E
BTDR
HAS
A 7
SECO
ND O
N DE
LAY
WHE
N "G
" IS
ENER
GIZE
D AN
D A
65SE
COND
OFF
DEL
AY W
HEN
"G" I
S
DE-E
NERG
IZED
.
FL
FUS
IBLE
LINK
0140
A002
78-D
BLU
E Y
ELLO
W
SEE
NOTE
1
5) F
OR 20
8VAC
APP
LICAT
IONS
MOV
E BO
TH R
ED W
IRES
TO
CENT
ER T
AP.
SEE
NOTE
5HC
24V
24V240V
208V
C
HTR1
RD
DISC
DISC
RD
RD
WH
BL
BLBL
RD
RDGR RD
BKPU
PU
YLBR
BKRD
FCTR
EM
TL
HTR2
RDTL
RD
SEE
NOTE
1
GR
BR
FL
C GSU
XFMR
-C
R
NC
COM
NOXF
MR-R
EBTD
R
**
*
FL
SEE
NOTE
4
L1PO
WER
SUPP
LY
L2
SEE
2NOTE
SEE
NOTE
5
HC
L2L1
T2T1
RD
RD
WH
BLBL
BK RD
BK
BR
RD
RD RD
BK BK
BK
BK
RD
RD
RD
GR
SEE
NOTE
2
BK
PU
T1*
L1HC
HTR
HE
ATER
ELE
MENT
FC
FAN
CAP
ACIT
ORTL
T
HERM
AL LI
MIT
TR
TRA
NSFO
RMER
HC
HEA
TER
CONT
ACTO
R
8 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 9
Wiring Diagram (No Electric Heat) — ACNF18/ 24/ 30
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
W
arni
ngHi
gh V
olta
ge:
Dis
conn
ect
all
pow
er b
efor
e se
rvic
ing
or i
nsta
lling
thi
s un
it. M
ultip
le p
ower
so
urce
s m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r dea
th.⚡
10 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 11
Wiring Diagram — ACNF25/ 31
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
W
arni
ngHi
gh V
olta
ge:
Dis
conn
ect
all
pow
er b
efor
e se
rvic
ing
or i
nsta
lling
thi
s un
it. M
ultip
le p
ower
so
urce
s m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r dea
th.⚡
NO
TES:
1. R
ED W
IRE
TO B
E O
N T
RAN
SFO
RM
ER
TER
MIN
AL "3
" FO
R 2
30 V
OLT
S AN
D O
N
TER
MIN
AL "2
" FO
R 2
08 V
OLT
S.
2. C
ON
FIR
M S
PEED
TAP
SEL
ECTE
D IS
A
PPR
OPR
IATE
FO
R A
PPLI
CAT
ION
. IF
SPEE
D
TAP
S N
EED
S TO
BE
CH
ANG
ED, C
ON
NEC
T
APP
RO
PRIA
TE W
IRE
FRO
M M
OTO
R T
O
"Y" F
RO
M T
HER
MO
STAT
/CO
ND
ENSE
R (S
EE T
ABLE
-1).
3. A
STER
ISK
(*) I
ND
ICAT
ES T
HAT
HEA
TIN
G
ELE
MEN
T, T
HER
MAL
LIM
IT, R
ELAY
AN
D
INTE
RC
ON
NEC
TIN
G W
IRES
AN
D J
UM
PER
S
OF
HEA
TER
#2
ARE
DEL
ETED
WIT
H S
ING
LE
ELE
MEN
T U
NIT
S.
4. C
OLO
R C
OD
ES:
BK -
BLAC
K
BL
- BL
UE
BR -
BRO
WN
GR
- G
REE
N
PU
- PU
RPL
E
R
D -
RED
WH
- W
HIT
E
YL
- YE
LLO
W
PK
- PI
NK
5. W
IRIN
G C
OD
E:
FAC
TORY
WIR
ING
:
H
IGH
VO
LTAG
E
LO
W V
OLT
AGE
F
IELD
WIR
ING
:
H
IGH
VO
LTAG
E
6. C
OM
PON
ENT
CO
DE:
C -
CO
NTA
CTO
R
D
ISC
- D
ISC
ON
NEC
T SW
ITC
H
EM
-
EVA
POR
ATER
MO
TOR
F -
FUSE
HTR
- H
EATE
R E
LEM
ENT
TL -
T
HER
MAL
LIM
IT
TR
-
TRAN
SFO
RM
ER
M
C -
M
OTO
R C
ON
TRO
L BO
X
BTUh
PURP
LE18
000
PINK
2400
0
TABL
E-1
WIR
E CO
LOR
0140
A003
81-A
YELL
OW
HIG
H C
FMO
PTIO
N
RD
PK
PKG
R
PU
PU
F
12
3
54
24V
12
34
5
CL
GN
MC
240V
TR
HTR
1
HTR
2*
TL1
TL2*
DIS
C
SEE
NO
TE 1
C
L1L2
T1T2
BLBR
WH
BK
RD
BK
BL WH
WH
RD
RD
BL
RD
BK
BR
BK
BK
BKBK
RD
RD
RD
RD
GR
/YL
BLBL
BL
BK
GR
RD
BK
BK
BK
BK
BKR
D
RD
RD
OPT
ION
ALC
ONN
ECTI
ON
EM
WH
YL
YL
SEE
NO
TE 3
MO
TOR
CO
NN
ECTI
ON
SO
NLY
ON
E W
ILL
BE C
ON
NEC
TED
(SEE
NO
TE 2
)
UNU
SED
WIR
ES M
UST
HAV
E TH
EIR
EN
DS T
APED
OR
CAP
PED
FIEL
D C
ON
NEC
TIO
NS
SEE
NO
TE 2
USE
N.E
.C C
LASS
2 W
IRE
10 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com 11
Wiring Diagram (No Electric Heat) — ACNF25/ 31
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
W
arni
ngHi
gh V
olta
ge:
Dis
conn
ect
all
pow
er b
efor
e se
rvic
ing
or i
nsta
lling
thi
s un
it. M
ultip
le p
ower
so
urce
s m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r dea
th.⚡
NOTE
S:
1. RE
D W
IRE
TO B
E ON
TRA
NSFO
RMER
TE
RMIN
AL "3
" FOR
230 V
OLTS
AND
ON
TE
RMIN
AL "2
" FOR
208 V
OLTS
.
2. CO
NFIR
M SP
EED
TAP
SELE
CTED
IS
APPR
OPRI
ATE
FOR
APPL
ICAT
ION.
IF S
PEED
TA
PS N
EEDS
TO
BE C
HANG
ED, C
ONNE
CT
APPR
OPRI
ATE
WIR
E FR
OM M
OTOR
TO
"Y
" FRO
M TH
ERMO
STAT
/CON
DENS
ER (S
EE T
ABLE
-1).
3. AS
TERI
SK (*
) IND
ICAT
ES T
HAT
HEAT
ING
EL
EMEN
T, T
HERM
AL L
IMIT
, REL
AY A
ND
INTE
RCON
NECT
ING
WIR
ES A
ND JU
MPER
S
OF H
EATE
R #2
ARE
DEL
ETED
WIT
H SI
NGLE
EL
EMEN
T UN
ITS.
4. CO
LOR
CODE
S:
BK
- BLA
CK
BL
- BLU
E
BR
- BRO
WN
G
R - G
REEN
P
U - P
URPL
E
RD
- RED
W
H - W
HITE
Y
L - Y
ELLO
W
PK
- PIN
K
5. W
IRIN
G CO
DE:
F
ACTO
RY W
IRIN
G:
HIG
H VO
LTAG
E
LOW
VOL
TAGE
F
IELD
WIR
ING:
H
IGH
VOLT
AGE
6. CO
MPON
ENT
CODE
:
C -
CONT
ACTO
R
DIS
C -
DISC
ONNE
CT S
WIT
CH
EM
-
EVAP
ORAT
ER M
OTOR
F
-
FU
SE
HTR
- H
EATE
R EL
EMEN
T
TL
- T
HERM
AL LI
MIT
T
R -
TRA
NSFO
RMER
M
C -
MOT
OR C
ONTR
OL B
OX
BTUh
PURP
LE18
000
PINK
2400
0
RD
PK
PKGR
PU
PUW
H
F
12
3
54
24V
12
34
5
CL
GN
MC
TABL
E-1
MOTO
R CO
NNEC
TION
SON
LY O
NE W
ILL B
E CO
NNEC
TED
(SEE
NOT
E 2)
UNUS
ED W
IRES
MUS
T HA
VE T
HEIR
END
S TA
PED
ORCA
PPED
WIR
E CO
LOR
0140
A003
80-B
240V
TR
DISCFI
ELD
CONN
ECTI
ONS
SEE
NOTE
2US
E N.
E.C
CLAS
S 2
WIR
E
SEE
NOTE
1
RD
BK
RD
BK
BK
RD
RD
GR/Y
LBL
BL
GR
RD
YELL
OWHI
GH C
FMOP
TION
WH
YL
WIR
E IS
NOT
USE
D FO
R 'N
O HE
AT' V
ERSI
ON
YL
BK
RDEM
BL
BL
12 www.daikincomfort.com SS-DACNF SS-DACNF www.daikincomfort.com PB
Our continuing commitment to quality products may mean a change in specifications without notice. ©20196 • Houston, Texas • Printed in the USA.
Model Description
HPSK-01 Heat Pump Shut-off Relay Kit
Louvered Ceiling Access Panels
CAP-1/ 1L Fits ACNF18
CAP-2/ 2L Fits ACNF24/ 25
CAP-3/ 3L Fits ACNF30/ 31
Accessories