Mayo 2018
"REHABILITACIÓN DE CANCHA DE BALONCESTO SANTANA TAMAYO, MUNICIPIO TAMAYO, PROV. BAHORUCO"
![Page 2: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/2.jpg)
PLANTA DE LEVANTAMIENTOESC. 1:125 001
PLANTA LEVANTAMIENTO
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:125
![Page 3: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/3.jpg)
PLANTA DE DEMOLICIÓNESC. 1:125
002
PLANTA DE DEMOLICIÓN
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:125
TALA DE ÁRBOLES
DEMOLICIÓN
LEYENDA
2 UD
142.06 M2
![Page 4: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/4.jpg)
PLANTA DE CONJUNTOESC. 1:125
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
ÁRBOLES EXISTENTES(MANTENIMIENTO)
PUERTA CORREDIZA DEENTRADA
GRADAS
BANQUETAS
PEDESTAL
003
PLANTA DE CONJUNTO
1:125
![Page 5: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/5.jpg)
GRAVAL=131.30 M2
PUERTA EN MALLACICLÓNICA
L= 4MLHORMIGÓN VACIADO
A=592.73 M2
VERJA EN MALLACICLÓNICAL=119.85 ML
PLANTA DE ARQUITECTÓNICAESC. 1:125
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
004
PLANTA ARQUITECTÓNICA
1:125
![Page 6: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/6.jpg)
0.15 2.44 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.03 0.15
0.15
3.25
0.15
2.85
0.15
2.85
0.15
2.85
0.15
2.85
0.15
3.13
0.15
0.15
2.57
0.15
2.02
0.15
4.00 0.15 3.77 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.85 0.15 2.67 0.15
0.15
3.68
0.15
2.85
0.15
2.85
0.15
2.85
0.15
2.85
0.15
3.02
0.15
18.83
43.91
19.14
33.894.005.03
42.92
2.35
0.15
0.90
5.48
0.90
0.15
0.90
5.48
0.90
0.15
1.15
2.15 3.04 2.14 28.00 2.49 2.70 2.34
PLANTA DIMENSIONADAESC. 1:500 005
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
PLANTA DIMENSIONADA
1:125
![Page 7: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/7.jpg)
0.15 0.90 5.45 0.90 0.15 0.90 5.45 0.90 0.15
0.15 7.25 0.15 7.25 0.15
0.15 0.90 5.45 0.90 0.15 0.90 5.45 0.90 0.15
14.95
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.60
0.15
2.85
0.15
0.60
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.15 7.25 0.15 7.25 0.15
14.95
PLANTA - GRADASESC. 1:100
PLANTA ARQUITECTÓNICA DIMENSIONADA - GRADASESC. 1:100
SE
CC
IÓ
N A
-A'
2.85
006
DETALLE DE GRADAS
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:50
![Page 8: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/8.jpg)
1.75
0.20
0.25
2.00
ELEVACION LATERAL IZQ. - GRADASESC. 1:50
1.75
0.20
0.25
2.00
ELEVACION LATERAL DER. - GRADASESC. 1:50
TUBOS EN ACERO DE 4"
TUBOS EN ACERO DE 4"
MURO EN BLOQUES
0.80
MURO EN BLOQUES
0.80
ELEVACIÓN FRONTAL - GRADASESC. 1:100
MURO EN BLOQUES
MURO EN BLOQUES
ELEVACIÓN FRONTAL - GRADASESC. 1:100
007
DETALLE DE GRADAS
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:50
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A CANCHA SANTANA TAMAYO
LETRAS EN PVC H= 1PIELOGO EN VINYL SOBRE SYNTRAX
0.30
NOTA: ESTE LETRERO IRÁ EN UNASOLA GRADA, HACIA EL LADO DELA CALLE EN EL LATERAL DERECHO
![Page 9: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/9.jpg)
SECCIÓN A-A GRADASESC. 1:50
1.30
0.30
1.80
LOSA EN HORMIGÓN
0.20
0.13
008
DETALLE DE GRADAS
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:33 13
0.40
4Ø3/8"
4Ø1/2"
Ø3/8''@0.15
Ø3/8''@0.15
0.75
0.13
4Ø3/8"
4Ø1/2"
Ø3/8''@0.15
Ø3/8''@0.15
0.60
0.13
0.40
4Ø3/8"
4Ø1/2"
Ø3/8''@0.15
Ø3/8''@0.15
0.60
0.13
0.40
4Ø3/8"
4Ø1/2"
Ø3/8''@0.15
Ø3/8''@0.15
0.60
0.13
Viga Va
Muro de 6"
SECCIÓN ESTRUCTURAL GRADASESC. 1:50
0.45
Ø3/8"@0.20
0.25
0.40
0.20
0.85
3Ø3/8"
4Ø3/8"
EST.Ø3/8"@0.20
Ø3/8"@0.20
2CALZOS DE REC.
0.15
Ø3/8"@0.60
0.15
0.45
Ø3/8"@0.20
0.25
0.40
0.20
0.85
3Ø3/8"
4Ø3/8"
EST.Ø3/8"@0.20
Ø3/8"@0.20
2CALZOS DE REC.
0.15
Ø3/8"@0.60
SECCION 1-1 SECCION 2-2
0.20
0.20
COLUMNA CA
4Ø1/2"
EST.Ø3/8"@0.20
0.15
0.20
Viga VA
4Ø1/2"
EST.Ø3/8"@0.20
![Page 10: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/10.jpg)
2.50
0.15 2.35
2.50
0.15 2.35 0.15 2.25 0.15 2.25 0.15
32
2.35 0.15 2.35 0.15
2.502.502.402.40
4 51 6 7
0.1
52
.4
0
2.5
5
Planta de Fundaciones -Gradas
SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1' SECCION 1 - 1'
SECC
ION
2 - 2' SEC
CIO
N 2 - 2'
SECC
ION
2 - 2' SEC
CIO
N 2 - 2'
SECC
ION
2 - 2' SEC
CIO
N 2 - 2'
SECC
ION
2 - 2' SEC
CIO
N 2 - 2'
SECC
ION
2 - 2' SEC
CIO
N 2 - 2'
SECC
ION
2 - 2' SEC
CIO
N 2 - 2'
009
DETALLE DE GRADAS
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:50
2.50
0.15 2.35
2.50
0.15 2.35 0.15 2.25 0.15 2.25 0.15
32
2.35 0.15 2.35 0.15
2.502.502.402.40
4 51 6 7
0.1
52
.4
0
2.5
5
Planta Estructural-Gradas
![Page 11: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/11.jpg)
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
010
DETALLE DE TRAZADO
1:125
30.00
1.00 14.00 14.00 1.00
1.00
15.00
1.00
17.00
1.00 14.00 14.00 1.00
30.00
1.00
15.00
1.00
17.00
2.45
1.00
2.00
2.45
2.00
1.00
1.00
5.70
3.60
5.70
1.00
7.60 7.60
6.35
6.35
6.35
2.95
0.05
2.95
5.80
1.20
1.80
1.80 1.80
LINEA DE
1.25
LIMITE DE CANCHA
R6.25
R1.80
LOS TRES PUNTOS
0.05
.85
1.75
0.05
0.05
0.05
0.05
.85
.85
0.30
15.00
3.15
4.50 5.96 4.50
0.05
0.050.05
3.15
0.05
1.25
0.05 0.05
7.70
DETALLES DE CANCHAESC. 1:150
0.11 4.49 0.114.49
![Page 12: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/12.jpg)
0.20< H < 0.60 EST. Ø 3/8" @ 0.106 Ø 3/4"
3 Ø 3/4"
2 EST. Ø 3/8" @ .20
3 Ø 3/4" 2 Ø 1/2"2 Ø 1/2"
0.20 EST. Ø 3/8" @ 0.106 Ø 3/4"
AL TORNILLOCLAVO SOLDADO
4 TORNILLOSDE Ø 1/2" x 12"
4 TORNILLOSDE Ø 1/2" x 12"
AL TORNILLOCLAVO SOLDADO
H=0.50m
Ø1/2"0.20 A.D.COLUMNA
DETALLE SECCION DE TORNILLONO ESC.
SECCIONES SOPORTE DE TABLERONO ESC.
011
DETALLE DE TABLERO
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:125
![Page 13: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/13.jpg)
3 1/8 X 3 1/8
SOLDADURA TODO BORDE
SOPORTE DE MALLAPARTE INTERIOR TUBO
NO ESC.
DETALLE DE CAJUELA
TAPA DE 3 1/8 X 3 1/8 X 1/4
TUBO DE 6 ' X 6" X 1/4"
SOLDADURA
TUBO Ø 2 1/2" H.G.
SOLDADURA
GOZNE
2"RELLENO COMPACTADO
HORMIGON CICLOPEO
PLANCHUELA SOLDADA
CALICHE O GRANULAR
SECCIONES SOPORTE DE TABLERONO ESC.
RELLENO COMPACTADO
NIVEL CANCHA
Ø3/8" @ 0.30
3Ø3/8"
LOSA DE HORMIGON ARMADO(H = 0.10) CON MALLAELECTROSOLDADA DE(2.7 DE 0.20 X 0.20
C
PENDIENTE 0.002
HORMIGÓN ARMADO.
(H=.10)
L
BORDILLO
PENDIENTE 0.002
LOSA DE HORMIGÓN ARMADO (H= 0.10)
CON MALLA ELECTROSOLDADA DE (2.7 DE 0.20 X 0.20).
DETALLE DE BORDILLONO ESC.
SECCION DE FUNDACION
012
DETALLE DE TABLERO
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:125
![Page 14: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/14.jpg)
LIMITE AREA DE JUEGO
(min. 0.50)
variable
Ø 1/2" a 0.20 A.D
3 Ø 3/4"
2 Ø 3/8" de L=1.10 mts.
2 Ø 1/2" de L=1.10 mts.
3 Ø 3/8"
2 Ø 1/2"
A
EST. Ø 3/8" a .20
A
C
C
B
B
(COLOCACION DE TORNILLO)VER DETALLE
SECCION LONGITUDINAL SOPORTE TABLERONO ESC.
ELEVACION FRONTAL TABLERONO ESC.
013
DETALLE DE TABLERO
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:125
![Page 15: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/15.jpg)
S = 0.002 %
S = 0.002 %
S = 0.002 % S = 0.002 %
BOMBEO
BOMBEO
VACIADO Y PULIDO CON HELICÓPTERO.CORTES CON MÁQUINA EN PAÑOS DE 6.00 X 6.00 MT.
DISTRIBUCION PANOS Y ORDEN VACIADO HORMIGON SIMPLENO ESC.
S = 0.002 %
BOMBEO
BOMBEO
014
DETALLE DE VACIADO DE CANCHA
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:125
![Page 16: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/16.jpg)
Muro de bloques
Tubo de hierro Ø3"Malla Ciclónica
Pichon de columnacada 3 metros
2CALZOS DE REC.
0.40
Ø 3/8" @0.2m4Ø 3/8"
3 Ø 3/8"0.25
0.45
0.60
1.20
1.80
Perfil de hierrogalvanizado 2"
Cerradura decandado
015
DETALLE DE VERJA
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
1:33 13
DETALLE DE PUERTA ENTRADAESC. 1:50
DETALLE DE VERJAESC. 1:50
![Page 17: ACI NISDE EPRL NED OI A SI P M OY OC OL ACI LINV ......306 99.81 mata 307 99.66 mata 308 99.60 mata 309 99.52 mata 310 99.56 mata 311 99.58](https://reader036.vdocuments.site/reader036/viewer/2022071415/6110a747e9b3b03d397ded09/html5/thumbnails/17.jpg)
PLANTA ELÉCTRICA DE ILUMINACIÓNESC. 1:125
COMISION PRESIDENCIAL DE APOYOAL DESARROLLO PROVINCIAL
CPADP
C/ Dr. Delgado, Esq. Moises Garcia,Gazcue, Sto. Dgo., R.D.
TEL.: (809)-364-2189|FAX.: (809)- 688-1665E-Mail: [email protected]
NO. PAGINA:
CONTENIDO:
SELLO DE APROBACION:
EQUIPO DE TRABAJO:
DISEÑO ARQUITECTONICOARQ. SORIVIC RAMÍREZ
ENC. PROYECTO ARQ.ARQ.
ESTRUCTURALIng.
ELECTRICOING.
HIDRO-SANITARIOING.
Mayo 2018
codia 00000
codia 00000
codia 00000
codia 00000
codia 00000
PROYECTO:
CANCHA DE BALONCESTOSANTANA TAMAYO
Prov. BahorucoRepública Dominicana
D
A
R
S
R
I
C
R
V
I
E
L
O
I
C
I
M
O
R
P
S
O
N
D E
S
L
N
O
D
A
Y
P
E
O
A
L
L
E
A
O
OL
P
I
C
I
N
A
FECHA:
ESCALA:
016
PLANTA ELÉCTRICA DE ILUMINACIÓN
1:125
P.E.