  • 7/27/2019 Access Controller 9901A

    1/2

    1BTS-9901A Standalone Access Controller Product introduction

    This Radio Frequency Identification (RFID) access controller is the 3rd

    generation controller. With newly added functions it is one of the most advanced

    standalone access controller. The controller is built on powerful modern Central

    Processing Unit. It manages up to 500 card holders, and access mode can be set t o

    Authorized Card Only, Authorized Card or Public PIN and Authorized Card +

    Personal PIN. Additional functions includes: door sensor input, alarm relay output,

    safe mode and anti-break. Door bell, exit button and electric locks can be

    connected to the controller. When users forget the programming password, they

    can restore the factory default password without erasing the card holders

    information. It is ideal for different occasions such as business apartment,

    governmental, factory buildings and so on.

    2. Product specification

    Item Specification

    1 Voltage 12VDC+10%; Current 1.2A

    2 Relay output 12VDC/2A

    3 Dimension 116mm x 116mm x 20mm

    4 Weight 180g

    5 Temperature -10~55

    6 Humidity 20%~90%

    7 Capacity 500 cards, each with one Personal Password and one

    Public Password

    8 Reading Distance 5~15CM

    9 Compatible Cards EM or EM compatible cards 125KHz

    3. LED and Buzzer

    LED:

    Event Red LED Green LED

    Normal Flash once a second

    Authorized card On

    Unauthorized card On

    Door o en On

    Programming mode On Flash quickly

    Programming confirm On On

    Alarm Flash quickly

    Buzzer:

    Event Buzzer

    Authorized card Two short bee s

    Unauthorized card One lon bee

    Valid key input One short beep

    Valid Password entered Two short beeps

    Invalid Password entered One long beep

    In alar Continuous lo

    n bee s

    4. Functions and settings

    1) Default password: programming password: 990101, public

    password: 1234, personal password: 0000.

    2) Enter programming mode: Press [*]+[990101]

    3) Settings (Enter programming mode firstly, letters inside []

    represents the key to press)

    A. Change programming password:

    Press [0]+ [new 6 digits pa ssword]+ [confirm new password]

    B. Change access mode:

    Press [1]+[0] (Authorized Card or Public Password)

    Press [1]+[1] (Authorized Card and Personal Password)

    Note: If access mode is set to Authorized Card and Personal

    Password, card holders should input personal password within 10

    seconds after presenting their cards to the reader. The personal

    password can not be used alo ne.The default mode is Authorized

    Card Only.

    C. Set authorized card:

    Press [5]+ [3 digits card index 1]+ [card index 2]+ !+[card index

    n]+[*]

    If the cards are presented in sequence, all of them will be enrolled

    after [*] pressed. Card index ranges from 001 to 500 exclusively.

    Default personal password: 0000

    D. Delete authorized card: (in 3 ways):

    Press [86] to delete all cards

    Press [7]+presenting the card+[*] to delete specific card

    Press [7]+ [3 digits card index]+[*] to delete specific card

    E. Set door opening time:

    Press [2]+time+[TT]

    [TT] is seconds in 2 digits. Default is 3 seconds, that is TT=03.

    F. Set door sensor input:

    Press [6]+[0] to disable the input

    Press [6]+[1] to enable the input

    G. Set alarm delay time:

    Press [82]+[TT]

    [TT] is seconds in 2 digits. If it i s 3 seconds, that is TT=03.

    H. Set door sensor alarm:

    Press [8]+[0] to disable

    Press [8]+[1] to enable

    I. Set anti-dismantle alarm:

    Press [4]+[0] to disable

    Press [4]+[1] to enable

    J. Change public password:

    Press [3]+ [new 4 digits password] (default 1234)

    When public password or personal password is 0000, password is

    invalid under access mode of "card or password#

    K. Press [86] to restore factory defaults.

    4)

    Exit programming mode

    Press [*] to exit programming mode.

    5) Change personal password

    A.Press [1]+[2] to disable changing personal password.

    B.Press [1]+[3] to enable changing personal password.

    C.Press [#]+presenting the card+[ 4 digits original password]

    (default 0000) +[4 digits new password] +[ confirm new password]

    6)

    Restore the programming password

    Short J2 on board to restore the default programming password. All

    other information will be kept.

    5. Frequently asked questions

    Q: After the lock is opened, there are 8 short beeps.

    A: The controller needs higher voltage; the power supply should be

    checked.

  • 7/27/2019 Access Controller 9901A

    2/2