acbel polytech inc._fsd005_400w_ecos 3624_report.pdf

Upload: carlos-olivera

Post on 20-Feb-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/24/2019 ACBEL POLYTECH INC._FSD005_400W_ECOS 3624_Report.pdf

    1/1

    80 PLUS Verification and Testing Report

    TYPICAL EFFICIENCY (50% Load): 92.68%

    AVERAGE EFFICIENCY : 91.37%

    80 PLUS COMPLIANT: YES

    Value Units100-240 Volts

    4.85 Amps

    50/60 Hz

    400 Watts

    Note: All measurem ents were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current W aveform (ITHD = 2.8%, 50% Load)

    IRMS PFA -12V 3.3V 5V 5Vsb

    0.42 0.98 6.70% 10% 47.04 0/0 3.3/0.9 5.1/0.9 5/0.2 40.48 86.06%

    0.77 0.99 5.81% 20% 88.51 0/0 3.3/1.8 5.1/1.8 5/0.3 80.96 91.48%

    1.90 1.00 2.80% 50% 218.28 0/0 3.3/4.5 5/4.4 5/0.8 202.29 92.68%

    3.91 1.00 3.17% 100% 448.60 0/0 3.3/8.9 5.1/8.9 5/1.6 403.60 89.97%

    OutputWatts

    12.1/26.4

    12.1/13.2

    Efficiency%

    12.1/2.6

    12.1/5.3

    Test Date

    Input Frequency

    3624

    Type

    Ecos ID #

    Model Number

    6/20/13

    2013

    Serial Number

    ACBEL POLYTECH INC.

    FSD005

    006

    Manufacturer

    Rated Output Power

    ITHD

    (%)

    Year

    1U

    Rated SpecificationsInput Voltage

    Input

    Watts

    Load

    (%) 12V (cumulative of 12V1, 12V2, etc.)

    DC Terminal Voltage (V)/ DC Load Current (A)

    Input Current

    10%

    20%

    30%

    40%

    50%

    60%

    70%

    80%

    90%

    100%

    Efficiency(%)

    Efficiency of the Power Supply

    Efficiency %

    Input Watts

    Output Watts

    .

    50.00

    100.00

    150.00

    200.00

    250.00

    300.00

    350.00

    400.00

    450.00

    500.00

    Power(Watts)

    Input and Output Power

    -3

    -2

    -1

    0

    1

    2

    3

    -200

    -150

    -100

    -50

    0

    50

    100

    150

    200

    0 0.003 0.006 0.009 0.012 0.015Current(A)

    Voltage(V)

    Time (s)

    Input Current and Voltage Waveforms

    Voltage Current

    0% 25% 50% 75% 100% 125%

    Loading (% of Rated Output Power)

    0.00

    20% 50% 100%

    Loading (% of Rated Output Power)

    These tests were conducted by a third party independent testing firm on

    behalf of the 80 PLUS Program. 80 PLUS is a certification program topromote highly-efficient power supplies (greater than 80% efficiency in theactive mode) in technology applications. http://www.80plus.org/