ac9400[1].pdf
TRANSCRIPT
Time & Attendance /Access ControlUser's Manual
AC-9400 Series
M95-5032
Information
Technical And Operational Description
Connection Of Multiple Units
Connections
Contents
........................................................................................... 1
4
5
16
27
...........................................................................................
.....................................................................................
..............................................
............................................................
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for aClass A digital device, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference whenthe equipment is operated in a commercial environment. This equipmentgenerates, uses, and can radiate radio frequency energy and, if not installedand used in accordance with the instruction manual, may cause harmfulinterference to radio communication.Operation of this equipment in a residential area is likely to cause harmfulinterference in which case the user will be required to correct the interferenceat his own expense.
30...................................................................................Specifications
31..........................................................................................
Communication Protocol 33...................................................................
Introduction
Installation
Information
AC9400 Access Control
AC-9400( Main Unit only )
AC-9400A(With 2nd Reader : PCR943A-01)
metal-wall mounting possible
MACHINE TYPE FUNCTION
- 1 -
AC-9400B(With 2nd Reader : PCR943-01)metal-wall mounting possible
AC-9400C(With 2nd Reader : GP30W-01)
OPTIONAL
GNETVER 1.2
RS- 485255
RTC
RS-232
RFID
BEEP
TESTAUTO
PASSBACKANTI
READER
EXTKEYPAD&
8096USER CARD
80ZONE TABLE
32SENSOR TABLE
28336REC QUEUE
GNETVER 1.2
RS- 485255
RTC
RS-232
RFID
BEEP
TESTAUTO
PASSBACKANTI
READEREXT8096
USER CARD
80ZONE TABLE
32SENSOR TABLE
28336REC QUEUE
GNETVER 1.2
RS- 485255
RTC
RS-232
RFID
BEEP
TESTAUTO
PASSBACKANTI
8096USER CARD
80ZONE TABLE
32SENSOR TABLE
28336REC QUEUE
GNETVER 1.2
RS- 485255
RTC RS-232
RFID
BEEP
TESTAUTO
PASSBACKANTI
8096USER CARD
80ZONE TABLE
32SENSOR TABLE
28336REC QUEUE
READEREXT
Information
Standard Package
User's Manual
Access Control
AC-9400 SeriesAC-9400 SeriesAC-9400 SeriesAC-9400 Series
M95-5034
Wall-mounting screw Kit( ASY-M93-1049-18 )
User's Manual( M95-5032 )
Software Disk( DISK5078 )
RS-232 Cable( WAS-1436 )
Wire for External Sensor /Lock/Alarm( WAS-1466 )
Main unit(AC-9400 )
Power Adaptor DC12V/120VAC ( APR-1014 )or DC12V/230VAC ( APR-1015A )
Screw Mounting Template( M92-5016 )
- 2 -
Cable for External Reader or Push button ( Egress Switch )
( WAS-1465 )
NO:123411
NO:123412
Test Card( M95-5026 )
Information
Optional
RS-485/RS-232 Converter( CON485 )
- 3 -
RS-485 Cable( WAS-1467 )
Order Information
A C 9 4 0 0 - 0 0
With 120VAC AdaptorU
E With 230VAC Adaptor
No Power Adaptor
With 2nd Reader PCR943A-01A
B
C
With 2nd Reader PCR943-01
With 2nd Reader GP30W-01
No 2nd Reader
25P Male / 9P Female RS232 Connector(CN5-1049)
Cable For Multiple Connect( WAS-1432 )
IntroductionIntroductionIntroductionIntroduction
AC-9400 is a highly flexible time & attendance / access control terminal. Itmay control the electric lock by using the RFID card. It offers reliable andfuture-oriented time & attendance / access control solution to meet mostrequirements in most areas. It can be used either as an off-line stand-aloneaccess control unit or as an on-line access control terminal through RS-485 orRS232 interface. The major features of Model AC9400 are:
Can be used either as an off-line stand-alone unit or as an on-line terminal.4 character LED to display message, and clock time.
Use proximity CardProvides RS-232 communication interfaces for remote commandprogramming and data collection. RS-485 interface is optional.
The number of user's card can be from 000000 to FFFFFF,but maximum 8096user's card.
Contain 512 K bytes Flash Memory buffer, store up to 28,336 records .
Provide a connection for indoor egress switch or one button on keypad toopen the door lock from inside the room. But there is no 2nd reader whenegress switch is connected.
Door lock open period is programmable from 1 to 255 seconds.
Built-in Real-Time Clock (RTC) module.
Use non-volatile memory, the memory will never lose when power failure.
- 4 -
Personal ID number (PIN) can be from 0 to 9, 00 to 99, 000 to 999, 0000 to9999, 00000 to 99999, 000000 to 999999.
Two external drives : Drive 1 for door lock, Drive 2 for alarm.
Provide a connection for door sensor to detect the door security.Provide a connection for external second card reader.Provide a 7x2 keypad to enter the PIN or to program the unit.
Door open mode can be set as " read card only" or "press keypad only" or"read card plus press keypad".
Provide two serial port connectors for daisy-chain connection of multi-unitapplications, up to 255 units.Provide RS-232 communication interface. RS-485 version for long-distanceconnection is also available.
Alarm active period is programmable from 1 to 65535 seconds.
Allows 80 time table for Access control Time zone.Allows 32 time table for Sensor active Time zone.
Use PC to set Master System Code / Machine ID / User's Card / User TimeZone / Sensor Time Zone / Door Open Duration / Clock Time / Anti-passbackON or OFF / Sensor detect ON or OFF / Baudrate...etc.
Can use keypad to display Firmware Version / Machine ID / Records Number /User's Card Number / Year / Month and Date / Machine Status.
Front Panel
Technical And Operational DescriptionTechnical And Operational DescriptionTechnical And Operational DescriptionTechnical And Operational Description
- 5 -
1
2
3
1
2
3
DISPLAY WINDOW
CARD READER
KEYPAD
The display can show Time,Week Day,Status of card readingand some other messages.
Approach the card here to read
To enter the PIN or to program the unit or to set somemessages.
Technical And Operational Description
- 6 -
1
2
3
4
5
HOST JACK
NEXT JACK
EXT. RDR JACK
ALARM JACK
LOCK JACK
For connection to the host computer or the preceding AC9400access control unit.
For connection to the next AC9400 access control unit.
For connection to the external second reader when the AC9400main unit is installed inside or connection to the egress switchwhen the AC9400 main unit is installed outside
For connection to the external alarm.
For connection to the external lock.(electric strike)
6 SENSOR JACKFor connection to the external door sensor.
Rear Panel
1 2 3
4
5 6
7
7 POWER JACKPlug in the power for the access control . DC12V/500mA
READY
ERROR
SUN MON TUE WED THU FRI SAT
5
2
1
3
4
- 7 -
1
2
3
4
5
TIME OR MESSAGE DISPLAY
WEEK DAY DISPLAY
READY
ERROR
STATUS INDICATOR
It display clock time at normal use. It will display somemessage when reading a card or entering PIN pad or settingparameters.
It displays week day at normal use.It will display some meaningwhen setting parameters.
It means the machine is ready for use.
It means reading a card with error or entering PIN pad witherror
It shows the communication status with PC. It will blink whencommunication is going and message is sending.
DISPLAY
Technical And Operational Description
Technical And Operational Description
- 8 -
1 HOST: connect to PC or from the former unit
Connectors on back cover
1
4
6
3
7
5 2
CTS123
PIN
45678
FUNCTION
TXDRTSRXD
RS485+SG
RS485-NC
HOST
CTS123
PIN
45678
FUNCTION
TXDRTSRXD
RS485+SG
RS485-NC
RS-232
CTS123
PIN
45678
FUNCTION
TXDRTSRXD
RS485+SG
RS485-NC
RS-485
12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
PIN FUNCTIONNEXT
12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
PIN FUNCTIONRS-232
12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
PIN FUNCTIONRS-485
2 NEXT: connect to next unit
Technical And Operational Description
PIN
NO1COM2NC3
DC 12V 10% / 500mA
NO :COM :
NC :
123456
PIN FUNCTIONALARM
Normal OpenCommonNormal Close
- 9 -
3 EXT.RDR : Connect External 2nd Reader or door open push button(Egress switch)
4 ALARM : Dry contact relay connector for external alarm
7 DC12V : Power supply connector
NO1COM2NC3
NO :COM :
NC :
PIN FUNCTIONLOCK
Normal OpenCommonNormal Close
5 LOCK : Dry contact relay connector for electric strike
GND1SEN212V3
GND :SEN :VCC :
PIN FUNCTIONSENSOR
GroundSensor InputPower Output ( Direct Connect Power )
6 SENSOR : Dry contact relay connector for door sensor
VCC * VCC *
D1D0
GNDGND
FUNCTIONEXT. RDR
* Direct Connect Power Input DC12V
PIN123456
VCC VCC PB * PB *GNDGND
FUNCTIONEXT. PUSH BUTTOM
* PIN3,PIN4 must Connect together
Technical And Operational Description
- 10 -
1. Keypad Operation at "READY" standby mode
F1F1F1F1 **** PPPP PPPP PPPP PPPP
1-2. Enter Message Displaying mode
1-3. Enter PIN number to open door
1-1. Enter Parameter Setting mode
Key
Exp. You must enter Setting mode when you want to change the Master PINor the Machine Address number or some parameters.
ENTENTENTENT
Symbol PPPP PPPP PPPP PPPP Master PIN number of the unit (Default :0000 )
F2F2F2F2
You must enter Message Displaying mode when you want to see someMessage, Such as Firmware Version, Machine Address, Summary ofthe Registered card, Summary of the Records, Year, Date (Month/Day), Baud rate, Door Sensor ON/OFF, Lock ON/OFF, Anti-PassbackON/OFF etc.
None
ENTENTENTENT
XXXX XXXX XXXX XXXX XXXX XXXX
Can be any number but maximum 6 digits.
ENTENTENTENT
XXXX XXXX XXXX XXXX Registered PIN numberXXXX XXXX
KEYPAD OPERATION
F1F1F1F1 **** PPPP PPPP PPPP PPPP
1-4. Relieve Alarm
This is the same operation as (1-1) Paragraph,but it will relieve thealarm when the alarm is activating. It would enter Setting mode whenthe Machine is at normal " READY" standby mode.
ENTENTENTENT
PPPP PPPP PPPP PPPP Master PIN number of the unit (Default :0000 )
Key
Exp.
Symbol
Key
Exp.
Symbol
Key
Exp.
Symbol
Technical And Operational Description
- 11 -
2. Keypad Operation at Parameter Setting Mode
0000 **** PPPP PPPP PPPP PPPP
2-1. Change Master PIN number of the unit
Change Master PIN number of the unit.
ENTENTENTENT
PPPP PPPP PPPP PPPP New Master PIN number you want.
1111 **** AAAA AAAA AAAA
2-2. Change Machine Address number
1 Machine Address number (Machine ID) Factory Default is 0002.There are many AC9400 units connected in one network,you have to set every unit with a different Machine Address number before connected to the network. Also the Machine Address number for each unit must not be 000 .
ENTENTENTENT
AAAA AAAA AAAA
****
2-3. Back to "READY" Standby Mode from Setting Mode
1. The unit will go back to "READY" Standby Mode from Setting Mode.2. If there is no keypad pressed or no card reading in 15 seconds, the machine will go back to " READY" standby Mode automatically.
ENTENTENTENT****
1-5. One key to open door
When the AC9400 main unit is installed inside the room and with theexternal 2nd reader installed outside and you would push one key (onebutton) to open door from inside, instead of reading a card, you mayset the AC9400 one-key-to-open-door function to be enabled. You canpress one key to open the door when the one-key-to-open-doorfunction is enabled.
ENTENTENTENT
None
ENTENTENTENT
New Machine Address number you want.
Key
Exp.
Symbol
Key
Exp.
Symbol
Key
Exp.
Symbol
Key
Exp.
Symbol None
Technical And Operational Description
- 12 -
3. Keypad Operation at Message Displaying Mode
ENTENTENTENTFirmwareVersion
MachineAddress ENTENTENTENT
Sum of theRegistered cards ENTENTENTENT
Sum of therecords
ENTENTENTENT Year ENTENTENTENT Date ENTENTENTENTOther
Parameters ENTENTENTENT
The 4-digit display will show the Firmware Version of the unit.Display [1.0r0] : <1.0> Firmware Version, <r0> Revised Number.
The 4-digit display will show the Machine Address of the unit.Display [A000] : <A> Display Address function , <000> Machine Address
The 4-digit display will show the Summary number of the Registered Cards.Display [0000] : <0000> Total number of the Registered Cards
The 4-digit display will show the Summary number of the Records.Display [0000] : <0000> Total number of the Records
The 4-digit display will show the existing Year of the unit.Display [2000] : <2000> Existing Year of the Machine
The 4-digit display will show some other parameters.Display [-L-2] : 1st <-> No sensor function, 2nd <L> Lock will activatewhen reading a card or pressing keypad, 3th <-> No Anti-passbackfunction, 4th <2> Baudrate 9600 BPS.
The 4-digit display will show the existing Date of the unit.Display [0612] : <06> Month, <12> Day
1.If there is no card reading or no keypad pressing in 5 seconds at Message Displaying Mode,the Machine will go back to "READY" Standby Mode automatically.
ITEM1 2 3 4
DISPLAYDIGITAL
X.X r Y
A XXX
XXXX
XXXX
XXXX
XX YY
X Y Z P
DEC.
ASCII
DEC.
DEC.
DEC.
DEC.
DEC.
0(2400BPS)/1(4800BPS)/2(9600BPS)/3(19200BPS)
COMMENT
Firmware Version [X.X]: 1.0 ~ 9.9Revised number [Y]: 0 ~ 9
Machine Address [XXX]: 000 ~ 255
Sum of the Registered cards [XXXX]: 0000 ~ 8096
Sum of the records [XXXX]: 0000 ~ 9999
Year [XXXX]: 2000 ~ 2100Month [XX]: 01 ~ 12 / Day [YY]: 01 ~ 31
2.The operation of the Message Displaying Mode,some parameters is as below :
LED
SUN
SAT
MON
TUE
WED
THUFRI
FirmwareVersion
MachineAddress
Sum of theRegistered cards
Sum of therecords
Year
Date
OtherParameters
FirmwareVersionMachineAddress
Sum of theRegistered cards
Sum of therecords
YearDate
OtherParameters
Disable
---
Enable
SLA
ITEM
Sensor Detect
Lock
Anti-passback
Baud Rate
X
Y
Z
P
Key
Exp.
Symbol
- 13 -
Status and Control Displaying
Technical And Operational Description
READY
ERROR
SUN MON TUE WED THU FRI SAT
F1 **** PPPP PPPP PPPP PPPP ENT
READY
ERROR
SUN MON TUE WED THU FRI SAT
READY
ERROR
SUN MON TUE WED THU FRI SAT
READY
ERROR
SUN MON TUE WED THU FRI SAT
Setting Mode
0 **** PPPP PPPP PPPP PPPP ENT
Change Master PIN
1111 **** 1111 2222 3333 ENT
Change Machine Address
**** ENT
Back to Standy Mode
****
ENT
One-key-to-open
READY
ERROR
SUN MON TUE WED THU FRI SAT
READY
ERROR
SUN MON TUE WED THU FRI SAT
F1 **** PPPP PPPP PPPP PPPP ENT
Relieve Alarm
XXXX XXXX XXXX ENT
Enter PIN
READY
ERROR
SUN MON TUE WED THU FRI SAT
ENT
Message Displaying Mode
F2
MessageDisplaying
Mode
"READY"Standby
Mode
ERROR
OPEN DOOR
ALARMING
PROGRAMMING
STANDBY
ADDRESS=123PASSWORD
- 14 -
Technical And Operational Description
READY
ERROR
SUN MON TUE WED THU FRI SAT
READY
ERROR
SUN MON TUE WED THU FRI SAT
READY
ERROR
SUN MON TUE WED THU FRI SAT
ENT
Keypad
MessageDisplaying
Mode
READY
ERROR
SUN MON TUE WED THU FRI SAT
NUMBER OF RECORDS = 0109
FIRMWARE VERSION : 1.0R0
MACHINE ID : 123
NUMBER OF USER CARD = 0010
ENT
Keypad
ENT
Keypad
ENT
Keypad
ENT
Keypad
ENT
Keypad
ENT
Keypad
READY
ERROR
SUN MON TUE WED THU FRI SAT
YEAR = 2000
READY
ERROR
SUN MON TUE WED THU FRI SAT
DATE: 10/20
READY
ERROR
SUN MON TUE WED THU FRI SAT
ANTI-PASSBACK : OFF LOCK ACTIVE : ON
SENSOR DETECT : ONBAUDRATE : 9600 BPS
- 15 -
Technical And Operational Description
READY
ERROR
SUN MON TUE WED THU FRI SAT
READ CARD ONLY
READY
ERROR
SUN MON TUE WED THU FRI SAT
READY
ERROR
SUN MON TUE WED THU FRI SAT
KEYPAD ONLY READ CARDPLUS KEYPAD
NO:123412
NO:123412
OK ERROR
OKERROR
READY
ERROR
SUN MON TUE WED THU FRI SAT
ERROR CODE
A B
B
123456789
Card ID not existTime zone not fitAnti-passback errorOpen (Out) / Anti-passbackOpen (Entry) / Anti-passbackAnti-passback buffer is full.Not input passwordInput password is errorOpen
A
12
Internal ReaderExternal Reader
ERROR CODE TABLE
9 Internal KeypadA External Keypad
INPUT ID
OPEN ER__
E R -
ConnectionsConnectionsConnectionsConnections
- 16 -
PC
CONNECT TO PC
RS-485 INTERFACE RS-485
RS-232 INTERFACE RS-232
PC
PC
CONNECT
WAS-1436
AC-9400
AC-9400
WAS-1467
CON-485CN5-1049
AC-9400
RS-232/RS-485 Converter
Connections
- 17 -
BLACKORANGE
GRAYCOLOR
YELLOWGREEN
RED
RJ-11 8P8C PIN123456
DB 9P FEMALE PIN7283
NC *5
CABLE
RS-232 INTERFACE RS-232
RS-485 INTERFACE RS-485
BROWNBLUE 7
8 NC * NC *
RJ-11 8P8C PIN123456
WIRECUT*CUT*CUT*CUT*
5CUT*
78
7CUT*
* NC - No Connect
WAS-1436
WAS-1467
BLACKORANGE
GRAYCOLOR
YELLOWGREEN
RED
BROWNBLUE
PIN1
PIN8
PIN1
PIN8
PIN7PIN5
* CUT - Cut wire
WAS-1436 : LENGH - 2000 mm , WIRE - 8P8C / AWG #28
WAS-1467 : LENGH - 2000 mm , WIRE - 8P8C / AWG #26
Connections
- 18 -
INTERFACE
RS-232 INTERFACE RS-232
RS-485 INTERFACE RS-485
PC
CTS123
PIN
45678
FUNCTION
TXDRTSRXD
RS485+SG
RS485-NC
HOST
CTS123
PIN
45678
FUNCTION
TXDRTSRXD
RS485+SG
RS485-NC
HOST
PC
VCC123
PIN
4
FUNCTION
GNDRS485-RS485+
CON485
WAS-1436PLUG
12345678
BLACKORANGE
GRAYCOLOR
YELLOWGREEN
RED
BROWNBLUE
DB97283
NC5
NCNC
DCD123
PIN
45678
FUNCTION
RXDTXDDTRSG
DSRRTSCTS
PC RS232
9 RI
WAS-1467
BLACKORANGE
GRAYCOLOR
YELLOWGREEN
RED
BROWNBLUE
PLUG12345678
WIRECUT*CUT*CUT*CUT*
5CUT*
7CUT*
RS-232/RS-485 Converter
CON485
Connections
- 19 -
CONNECT TO EXTERNAL READER
PCR-943A-01 / PCR-943-01
GP30W-01
AC-9400
AC-9400
GP30W
PCR-943A-01 PCR-943-01
RED
BLACK
GREEN
WHITEYELLOW
WHITE
BLUE
GREEN
BLACK
RED
YELLOW
BLUE
BROWN
ORANGE
( NOT CONNECT )
CONNECT
WAS-1465
Connections
- 20 -
PCR-943A-01 / PCR-943-01
GP30W-01
GP30W-01
PCR-943A-01
PCR-943-01
RED
BLACK
GREEN
WHITE
YELLOW
BLUE
BROWN
ORANGE
RED123
PIN
456
COLOR
BROWNGREENWHITE
YELLOWBLACK
PIN 1
PIN 6
POWERFUNCTION
POWERD1D0
GNDGND
Power DC5 - 13.5VFUNCTION
Power GroundClock/D1
Data/RS232/D0CP
Program InputExt. Buzzer
Ext Led
REDCOLOR
BLACKWHITEGREEN
ORANGEYELLOW
BLUEBROWN
123
PIN
456 BLUE
COLOR
YELLOWGREEN
REDBLACKWHITE
BLUE
YELLOW
GREEN
RED
BLACK
WHITE
* YELLOW Connect to WHITE for Wiegand Interface
PIN 1
PIN 6
CABLE
PCR-943A-01 / PCR-943-01
WAS-1465 GP30W
WAS-1465 : LENGH - 300 mm , WIRE - 6P6C / AWG #24
Connections
- 21 -
PCR-943A-01 / PCR-943-01
GP30W-01
PCR-943A-01
PCR-943-01
PIN 1
PIN 6
POWERFUNCTION
POWERD1D0
GNDGND
REDCOLOR
BROWNGREENWHITE
YELLOWBLACK
123
PIN
456
123
PIN
456
POWERFUNCTION
POWERD1D0
GNDGND
EXT. RDR PCR-943A-01 / PCR-943-01
GP30W-01
123
PIN
456 BLUE
COLOR
YELLOWGREEN
REDBLACKWHITE RED
COLOR
BLACKWHITEGREEN
ORANGEYELLOW
BLUEBROWN
VCCFUNCTION
GNDCLOCK/D1
DATA/RS232/D0CP
PROGRAMBUZZER
LED
123
PIN
456
POWERFUNCTION
POWERD1D0
GNDGND
EXT. RDR WAS-1465 GP30W-01
PIN 6
PIN 1
INTERFACE
Connections
- 22 -
CONNECT TO EXTERNAL PUSH BUTTOM
AC-9400PUSH BUTTOM
WHITE
BLUE
GREEN
BLACK
RED
YELLOW
( NO CONNECT)
PIN 6
PIN 1
CONNECT
CABLE
INTERFACE
123
PIN
456
POWERFUNCTION
POWERD1D0
GNDGND
EXT. RDR
123
PIN
456 BLUE
COLOR
YELLOWGREEN
REDBLACKWHITE
WAS-1465
PUSHBUTTOM
PUSH BUTTOM
LOOK " CONNECT TO EXTERNAL READER " PAGE
( EGRESS SWITCH )
WAS-1465
Connections
- 23 -
CONNECT TO EXTERNAL READER + PUSH BUTTOM
AC-9400PUSH BUTTOM
WHITE (+)
BLUE
GREEN ( D0 )
BLACK
RED ( D1 )
YELLOW ( - )
PIN 6
PIN 1
CONNECT
CABLE
INTERFACE
123
PIN
456
POWERFUNCTION
POWERD1D0
GNDGND
EXT. RDR
123
PIN
456 BLUE
COLOR
YELLOWGREEN
REDBLACKWHITE
WAS-1465
PUSH BUTTOM
PUSH BUTTOM
LOOK " CONNECT TO EXTERNAL READER " PAGE
( EGRESS SWITCH )
WAS-1465
CONNECT TO EXTERNAL READER
1N5819 *
1N5819 *
1N5819 X 2 *
CONNECT TOEXTERNALREADER
* 1N5819 is schottky barrier rectifiers . SPC => Io=1.0A , BVR=40V
++++
CONNECT TO EXTERNAL READER
Yellow/BlackWhite
GreenRed/Brown
Connections
- 24 -
CONNECT TO EXTERNAL ALARM
AC-9400 ALARM
WHITE
BLACK
RED
CONNECT
CABLE
INTERFACE
123
PINNO
FUNCTION
COMNC
ALARM
123
PIN COLORWAS-1466
ALARM
ALARM
ALARM POWER
123
PINWAS-1466
COLORRED
BLACKWHITE
RED
BLACKWHITE
PIN1
WAS-1466 : LENGH - 300 mm , WIRE - 3C / AWG #18
Connections
- 25 -
CONNECT TO EXTERNAL LOCK
AC-9400
LOCK
WHITE
BLACK
RED
CONNECT
CABLE
INTERFACE
123
PINNO
FUNCTION
COMNC
LOCK
123
PIN COLORWAS-1466
LOCK
LOCK
LOCK POWER
123
PINWAS-1466
COLORRED
BLACKWHITE
RED
BLACKWHITE
Connections
- 26 -
CONNECT TO EXTERNAL SENSOR
AC-9400
SENSOR
WHITE
BLACK
RED
CONNECT
CABLE
INTERFACE
123
PINGND
FUNCTION
SEN.12V
SENSOR
123
PIN COLORWAS-1466
SENSOR
SENSOR
123
PINWAS-1466
COLORRED
BLACKWHITE
DOOR
RED
BLACKWHITE
Connections
- 27 -
CONNECT TO POWER
AC-9400
CONNECT
INTERFACE
12
PINDC 12V POWER ADAPTOR
12
PINDC 12V
123
PINSENSOR
123
PIN
456
EXT. RDR
Power Adaptor DC12V/120VAC ( APR-1014A ) or DC12V/230VAC ( APR-1015A )
I NI NI NI N
OUTOUTOUTOUT GNDFUNCTION
SEN.12V
POWERFUNCTION
POWERD1D0
GNDGND
12 VFUNCTION
GND
12VFUNCTION
GND
1. "DC12V" input power direct connect to "EXT. RDR" and "SENSOR" .2. Power adaptor don't direct supply "ALARM" or "LOCK" power.
Power Adaptor
Connection Of Multiple UnitsConnection Of Multiple UnitsConnection Of Multiple UnitsConnection Of Multiple Units
- 28 -
PIN1
PIN8
WAS-1432 : LENGTH - 1000 mm , WIRE - 8P8C / AWG #28
BLACKORANGE
GRAYCOLOR
YELLOWGREEN
RED
8P8C PIN123456
8P8C PIN876543
BROWNBLUE7
821
WAS-1432
CABLE
PIN1
PIN8
PC
CONNECTION OF MULTIPLE UNITS TO PC
AC-9400
RS-232 INTERFACE RS-232
CONNECT
Connection Of Multiple Units
- 29 -
PC WAS-1436PLUG
12345678
RS232 HOSTAC9400 #1 WAS-1432
PLUG87654321
PLUG12345678
PC
WAS-1436
AC-9400 #1
AC-9400 #3AC-9400 #2
NEXT AC9400WAS-1432
WAS-1432 WAS-1432
1
2
3
4
5
6
7
8
9
DCD
RXD
TXD
DTR
SG
DSR
RTS
CTS
RI
12345678
CTSTXDRTSRXD
RS485+SG
RS485-NC
NEXT12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
7283
NC5
NCNC
DB9
HOSTAC9400 #2
12345678
CTSTXDRTSRXD
RS485+SG
RS485-NC
NEXTWAS-1432
PLUG87654321
PLUG12345678
HOSTAC9400 #3
12345678
CTSTXDRTSRXD
RS485+SG
RS485-NC
NEXT
NC
Up to 31units
12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
RS-485 INTERFACE RS-485
- 30 -
Connection Of Multiple Units
CON485 WAS-1467PLUG
12345678
RS232 HOSTAC9400 #1 WAS-1432
PLUG87654321
PLUG12345678
2
4
1
3
GND
RS485+
VCC
RS485-
12345678
CTSTXDRTSRXD
RS485+SG
RS485-NC
NEXTCUTCUTCUTCUT
5CUT
7CUT
WIRE
HOSTAC9400 #2
12345678
CTSTXDRTSRXD
RS485+SG
RS485-NC
NEXTWAS-1432
PLUG PLUG HOSTAC9400 #3
12345678
CTSTXDRTSRXD
RS485+SG
RS485-NC
NEXT
CN5-1049
PC AC-9400 #1
AC-9400 #3AC-9400 #2
NEXT AC9400
WAS-1432
WAS-1432 WAS-1432
WAS-1467
CON485
Up to255 units
12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
12345678
NCRS485-
SGRS485+
TXDCTSRXDRTS
87654321
12345678
RS-232/RS-485 Converter
SpecificationsSpecificationsSpecificationsSpecifications
RS232 Interface :
Power Supply :
Dimensions :
Mounting :
Environment :
RS232 , Half-Duplex , 8N1 , 9600 bps
ACDC DC 12V, 500mA
D 52 x W 192 x H 120 mm%
C/F Operating Temp : 0 ~ 55 C for AC9400 main unit -10 ~ 60 C for external readersStorage Temp : -10 ~ 55 CHumidity : 10 ~ 90 % relative
- 31 -
RS-232
GNETVER 1.2
Memory Size for Storing Data :
Communication Protocol :GIGA-TMS Net Version 1.2 (GNET V1.2)
RTC
RFID
RS-485 RS485 Interface :RS485 , Half-Duplex , 8N1 , 9600 bps
CLOCK :
Relay Contact Capacity for ALARM And LOCK :
* SuperFlash is a registered trademark of Silicon Storage Technology, Inc.
6A / AC 250V , 12A / DC 28VDC
RFID Proximity Card :125 KHZ , ASK , 64 Bits , Manchester Coding
CMOS SuperFlash * EEPROM 512K bytesR
READER
EXTKEYPAD&
EXTERNAL RFID READER ( 2nd Reader ):125 KHZ , ASK , 64 Bits , Manchester Coding Wiegand InterfacePCR943A-01: RFID Reader with keypad,Read range 5 ~10 cm,
Metallic wall workable, Temp. -10 ~ 60 C
Real Time Clock (RTC) module with built-in 10 year batteryClock accuracy is better than 1 minute per month at 25 C for the period of time-keeping time
Up to 1200 meters / Up to 255 Units on the bus
Electrically Life - 10 x 10 operations. Min.4
Wall-mounting
PCR943-01: RFID Reader without keypad,Read range 5 ~10 cm, Metallic wall workable, Temp. -10 ~ 60 C GP30W-01: RFID Reader without keypad,Read range 15 ~30 cm
for non-metallic wall mounting, Temp. -10 ~ 60 C
Up to 15 meters / Up to 31 Units
Up to 28336 records8096
USER CARD
80ZONE TABLE
32SENSOR TABLE
28336REC QUEUE
User Cards :
Time Zone Table :
Sensor Table :
Up to 8096 user cards
Up to 80 zone table
Up to 32 sensor working time table
Installation
1. Find and get the Screw Mounting template from the box and stick the template on the wall where you want to put the AC9400 unit.
2. Drill the 4 mounting holes through the Screw Mounting template if the wall is concrete.
3. Get 4 pieces of plastic bolts to insert into the 4 holes on the wall.
4. Use the special screw driver to remove the two special screws on the bottom of the unit to separate the front cover and back cover.
5. Get the back cover and have all the necessary wires go through the back cover and then mount the back cover on the wall with 4 screws through the screw mounting template.
6. Connect all the necessary wries into the connectors on the main unit put the front cover as the direction from top to bottom shown on the figure sketch.
7. Put the front cover with the back cover together.
8. Use the special screw driver to mount the two screws at the bottom of the unit and then stick the plastic plate to cover the screws.
9. Installation is finished.
- 32 -
AC-9400INSTALLATION
2. Get the back cover out of the front cover.
3. Put the back cover on the wall and drill the holes on the wall to mount the back cover on the wall. you must have all the necessary wires go through the back cover before you mount it on the wall.
1. Use the special screw driver to remove the two special screws at the bottom of the PCR943 unit to separate the front cover and back cover. 5. Put the front cover with the back cover together.
7. Use the plastic plate to cover the two screws.
8. Installation is finished.
- 33 -
PCR-943INSTALLATION
Installation
4. Connect all the necessary wires into the connector on the front unit and then put the front cover on the back cover as the direction from top to bottom shown on the figure sketch.
6. Use the special screw driver to mount the two special screw at the bottom of the unit.
Note
1.Do not install the external readerright on the back side of the Main unit to avoid mutual interference of the two RFID readers. If you have to install the external reader on the back side of the main unit,it must keep minimum 50 cm distance between the main unit and the external reader.
- 34 -
50 cm
50 cm
AC9400
PCR943A-01PCR943-01
GP30
AC9400
PCR943A-01PCR943-01
GP30
2.Better install the external reader aside from the Main unit at a distance 50 cm minimum to avoid multual interference.
4CAWG #24
WAS14652C
AWG #18
WAS1466
2CAWG #18
WAS1466
2CAWG #24
WAS1465
2CAWG #24
WAS14675C
AWG #28
WAS1436
2CAWG #22
APR-1014
2CAWG #24
--
5CAWG #24
WAS-14322C
AWG #24
WAS-1432
9CAWG #24
--
NEXT AC9400
GIGATMS Support wire nameMinimum wire acountMinimum wire AWG No.
- 35 -
Note
3. AC9400 SYSTEM
ALARM
LOCKSENSOR
SENSOR
CON485
PC
AC9400
POWER
EXTERNAL READERPUSH BUTTON
AUX. POWER