ac100-240v light fitting supply 1-10v dimmer light ......altum 78573, 78574, 78575dim-instruction...
TRANSCRIPT
-
Altum 78573, 78574, 78575
Instruction leaflet
Care and Safety• We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.• For your safety, always switch off the power supply before cleaning.
V4 19/12/2019
WWW.saxbylighting.com Saxby lighting. BH17 7BY
WiringHaving correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the connection block inside the product in the following way:
Check that...• You have correctly identified the wires. • The connections are tight.• No loose strands have been left out of the connection block.
• When completed, ensure that there are no bare or loosestrands of wire exposed, and cover all exposed areas of theconnection block with 2 layers of insulation tape.
SUPPLY
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
BLUE (N)
GREEN/YELLOW
BROWN (L)
4th BLOCK PROVIDED FOR LOOPTERMINATION IF NECESSARY
LIGHT FITTINGAC100-240V SUPPLY LIGHT FITTING1-10V dimmer
DIM+
DIM-
12V
PURPLE
GRAY
BLACK/WHITE
-
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
Technical data
Please read these instructions carefully before commencingany work.
This light fitting should be connected to a fused circuit.
The mains supply cable must have a minimum crosssectional area of 1.0mm².
Luminaires are only suitable for mounting onnon-combustible surfaces.
Take care not to drill into any pipes or mains cablesbeneath the surface during mounting holes preparation.
Never put anything on the product or hang anything onany part of this product.
This product is suitable only for dimming with 1-10V typedimmers.
This unit must be fitted by a competent and qualifiedelectrician.
Check the pack and make sure you have all of theparts listed.
To prevent electrocution switch off at mains supplybefore installing or maintaining this fitting.
Ensure other persons cannot restore the electricalsupply without your knowledge.
Install in accordance with IEE Wiring regulations andcurrent Building Regulations.
InstallationExisting fittings must be completely removed before installation of a new product. Before removing the existing fitting,carefully note the position of each set of wires. • Note that the power needs to be isolated/switched off at the fuse board.• The fixing point(s) selected must be capable of supporting the full weight of the light fitting.
• Installation method 1. (Use a hook)
• Installation method 2. (Use a bracket)
• Shade installation.
• Special reminder:This lamp can be used with sensor (model no: 78577 and 78774 ).For details on sensor installation, please see "Microwave motion sensor user's manual"
Cables must be protected using suitable conduit or plastictrunking.
Supply
Bulb Type:
Voltage: 240V~, 50 Hz
78575--200W LED, 6500K78573--100W LED , 6500K 78574--150W LED, 6500K
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
Conformity with all relevant EC Directive requirements.
Waste electrical products should not be disposed of with household waste.
Class I product, must be connected to earth.
Please recycle where facilities exist. Check with your Local Authority orlocal store for recycling advice.
Jet-proofIP65
If replacing an existing fitting, make a careful note of theconnections.
The Sensor and 1-10V dimmer can be used together. When the light is 100% on, customer can use 1-10V dimmer to dim the light.When the light is dim, customer can’t use 1-10V dimmer to dim the light.
Details wiring please refer to wiring diagram
Lampshade & Lens Accessories70° PC Reflector size
264mm
78580 78578 - 60° 78579 - 90°
90° Aluminium shade 60°/90° Lens
130mm
Ø353mm
78753
PC shade cover
78752
Ø180mm
Installation method 1.
Installation method 2.
Shade installation.
Hole dimension for mounting
Drilling a holein the ceiling,install a hook.
Hangingthe fixture
Connect the cables(See Wiring)
Fix thebracket
Drilling holes in the ceiling,and install the expansion screws
Adjust the bracketto the beam angleyou need
1. 2. 3.
79397(use for 78574/78575)78576(use for 78573)
75mm 90mm
35m
m 35mm
1.
2. 3. 4.
Remove three screwsthrough a wrench
Lamp-chimney Lock up three screws1. 2. 3.
1.Connect the AC cables. Brown--L, Blue--N, Yellow / Green--Ground.2.Connect the 1-10V dimmable cables. Purple--DIM+, Gray--DIM-, Black/White--12V, (Black/White--12V is suitable for Low Voltage Sensor)
1.Connect the AC cables. Brown--L, Blue--N, Yellow / Green--Ground.2.Connect the 1-10V dimmable cables. Purple--DIM+, Gray--DIM-, Black/White--12V, (Black/White--12V is suitable for Low Voltage Sensor)
Connectthe cables(See Wiring)
NOTICE:When the light is 100% on,customer can use 1-10Vdimmer to dim the light.When the light is dim,customer can’t use 1-10Vdimmer to dim the light.Details wiring pleaserefer to wiring diagram.
NOTICE:When the light is 100% on, customer can use 1-10Vdimmer to dim the light. When the light is dim, customer can’t use 1-10Vdimmer to dim the light.Details wiring please referto wiring diagram.
AC100-240V
1-10V
LNG
DIM+
DIM-12V
AC100-240V
1-10V
LNG
DIM+
DIM-
12V