ac100-240v light fitting supply 1-10v dimmer light ......altum 78573, 78574, 78575dim-instruction...

2
Altum 78573, 78574, 78575 Instruction leaflet Care and Safety We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. For your safety, always switch off the power supply before cleaning. V4 19/12/2019 WWW.saxbylighting.com Saxby lighting. BH17 7BY Wiring Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the connection block inside the product in the following way: Check that... You have correctly identified the wires. The connections are tight. No loose strands have been left out of the connection block. When completed, ensure that there are no bare or loose strands of wire exposed, and cover all exposed areas of the connection block with 2 layers of insulation tape. SUPPLY NEUTRAL EARTH (GREEN/YELLOW) SWITCHED LIVE BLUE (N) GREEN/YELLOW BROWN (L) 4th BLOCK PROVIDED FOR LOOP TERMINATION IF NECESSARY LIGHT FITTING AC100-240V SUPPLY LIGHT FITTING 1-10V dimmer DIM+ DIM- 12V PURPLE GRAY BLACK/WHITE

Upload: others

Post on 16-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • Altum 78573, 78574, 78575

    Instruction leaflet

    Care and Safety• We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.• For your safety, always switch off the power supply before cleaning.

    V4 19/12/2019

    WWW.saxbylighting.com Saxby lighting. BH17 7BY

    WiringHaving correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the connection block inside the product in the following way:

    Check that...• You have correctly identified the wires. • The connections are tight.• No loose strands have been left out of the connection block.

    • When completed, ensure that there are no bare or loosestrands of wire exposed, and cover all exposed areas of theconnection block with 2 layers of insulation tape.

    SUPPLY

    NEUTRAL

    EARTH (GREEN/YELLOW)

    SWITCHED LIVE

    BLUE (N)

    GREEN/YELLOW

    BROWN (L)

    4th BLOCK PROVIDED FOR LOOPTERMINATION IF NECESSARY

    LIGHT FITTINGAC100-240V SUPPLY LIGHT FITTING1-10V dimmer

    DIM+

    DIM-

    12V

    PURPLE

    GRAY

    BLACK/WHITE

  • Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.

    Warning

    Technical data

    Please read these instructions carefully before commencingany work.

    This light fitting should be connected to a fused circuit.

    The mains supply cable must have a minimum crosssectional area of 1.0mm².

    Luminaires are only suitable for mounting onnon-combustible surfaces.

    Take care not to drill into any pipes or mains cablesbeneath the surface during mounting holes preparation.

    Never put anything on the product or hang anything onany part of this product.

    This product is suitable only for dimming with 1-10V typedimmers.

    This unit must be fitted by a competent and qualifiedelectrician.

    Check the pack and make sure you have all of theparts listed.

    To prevent electrocution switch off at mains supplybefore installing or maintaining this fitting.

    Ensure other persons cannot restore the electricalsupply without your knowledge.

    Install in accordance with IEE Wiring regulations andcurrent Building Regulations.

    InstallationExisting fittings must be completely removed before installation of a new product. Before removing the existing fitting,carefully note the position of each set of wires. • Note that the power needs to be isolated/switched off at the fuse board.• The fixing point(s) selected must be capable of supporting the full weight of the light fitting.

    • Installation method 1. (Use a hook)

    • Installation method 2. (Use a bracket)

    • Shade installation.

    • Special reminder:This lamp can be used with sensor (model no: 78577 and 78774 ).For details on sensor installation, please see "Microwave motion sensor user's manual"

    Cables must be protected using suitable conduit or plastictrunking.

    Supply

    Bulb Type:

    Voltage: 240V~, 50 Hz

    78575--200W LED, 6500K78573--100W LED , 6500K 78574--150W LED, 6500K

    The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.

    Conformity with all relevant EC Directive requirements.

    Waste electrical products should not be disposed of with household waste.

    Class I product, must be connected to earth.

    Please recycle where facilities exist. Check with your Local Authority orlocal store for recycling advice.

    Jet-proofIP65

    If replacing an existing fitting, make a careful note of theconnections.

    The Sensor and 1-10V dimmer can be used together. When the light is 100% on, customer can use 1-10V dimmer to dim the light.When the light is dim, customer can’t use 1-10V dimmer to dim the light.

    Details wiring please refer to wiring diagram

    Lampshade & Lens Accessories70° PC Reflector size

    264mm

    78580 78578 - 60° 78579 - 90°

    90° Aluminium shade 60°/90° Lens

    130mm

    Ø353mm

    78753

    PC shade cover

    78752

    Ø180mm

    Installation method 1.

    Installation method 2.

    Shade installation.

    Hole dimension for mounting

    Drilling a holein the ceiling,install a hook.

    Hangingthe fixture

    Connect the cables(See Wiring)

    Fix thebracket

    Drilling holes in the ceiling,and install the expansion screws

    Adjust the bracketto the beam angleyou need

    1. 2. 3.

    79397(use for 78574/78575)78576(use for 78573)

    75mm 90mm

    35m

    m 35mm

    1.

    2. 3. 4.

    Remove three screwsthrough a wrench

    Lamp-chimney Lock up three screws1. 2. 3.

    1.Connect the AC cables. Brown--L, Blue--N, Yellow / Green--Ground.2.Connect the 1-10V dimmable cables. Purple--DIM+, Gray--DIM-, Black/White--12V, (Black/White--12V is suitable for Low Voltage Sensor)

    1.Connect the AC cables. Brown--L, Blue--N, Yellow / Green--Ground.2.Connect the 1-10V dimmable cables. Purple--DIM+, Gray--DIM-, Black/White--12V, (Black/White--12V is suitable for Low Voltage Sensor)

    Connectthe cables(See Wiring)

    NOTICE:When the light is 100% on,customer can use 1-10Vdimmer to dim the light.When the light is dim,customer can’t use 1-10Vdimmer to dim the light.Details wiring pleaserefer to wiring diagram.

    NOTICE:When the light is 100% on, customer can use 1-10Vdimmer to dim the light. When the light is dim, customer can’t use 1-10Vdimmer to dim the light.Details wiring please referto wiring diagram.

    AC100-240V

    1-10V

    LNG

    DIM+

    DIM-12V

    AC100-240V

    1-10V

    LNG

    DIM+

    DIM-

    12V