ac contactor - dixsen.com · ac contactor contactors provide remote control of primarily electric...

23
AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & h eating sy stems by cable. They protect the instru- ments and equipments against overload currents by using thermal relays, for Capacitor switching contactor:While switching on a capac- itive circuit, a high frequency (1...15Hz) and large transient current peaks are produced. Switching of capacitor for a single or one of the capacitor banks are different from each other. Step by step"switching on" operation is more difficult for contactor than capacitor bank. Because during this operation for capacitor bank, compensated current occurs. For this reas on selecting of suitable contactors the compensating current must be taken into considera tion for 5 0kVAr and abo ve, and for less than 50 kVAR can be omitted. IEC60947-4-1, EN60947-4-1 APPLICATION Fullfill following Standard Main and auxiliary contacts, coil and auxiliary contact blocks are easily installed and removed. The coils of contactors are safely co- ntrolled between 0.8 and 1.1 times of their rated coil voltage. They operate at full performance in the ambient temperature of -5 0 and +55 . The ability of assembling contactors to rails provides a great facility during installation. The ingredient of the material provides a resistance to an insulation voltage of 1000V. CONTACT Contactor damages and effects of these damages: There can be damages when the contactors are not used according to technical datas and then failures begin to occur at the feeding system. Reasons of Probable Cancellation of Contactors: Generally, contactors are the devices, which do not damage easily. If the selection is made correctly and operating conditions are not out of order, contactor can make millions times opening and closing safely. The reasons of the cancel lation and the ir so lutio ns are given below. Excessive length of cable of command circuit (coils) can cause some problems. Voltage is low during the long cables and this reason makes the closing difficultly and over big cross-sectioned cable capacitance obstruct opening. Generally advised cable cross-section and length are mentioned in catalogues. If the command circuit is longer than the advised valu e, higher contactor and more lower coil voltage, resistance or inductive impedance connection should be used. Dirt or foreign particles in the contactor, hard atmosphere conditions and corrosion can obstruct the closing operation of contactor. If we face a problem like this, contactor should be cleaned, appropriat ely. Th en th e cir cuit should be c hecked and modified for a more protective environment for the contactor. If there is a factor damaging the conduction, it should be removed. Events that can cause the contactor's, noisy operation is dust and having foreign particles in the air space e tc, un suit able voltage and frequency. Also defect of the nucleus surface because of long time operation. To obstruct all these, we should provide the clea- rness of the nucleus face and (if needed) coil changing should be made for voltage and frequency. Changing the coil: New coil is put on by pulling up screws, which are taking place on both sides of the contactor, separating the upper parts and taking the coil out off its socket. Much attention should be paid to placing on its spring that at the bottom side, during re-assembling. CONTACTORS DAMAGES AND REPAIRS www.dixsen.com M-01 M

Upload: others

Post on 18-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

AC CONTACTOR

Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-

ments and equipments against overload currents by using thermal relays, for Capacitor switching contactor:While switching on a capac-

itive circuit, a high frequency (1...15Hz) and large transient current peaks are produced. Switching of capacitor for a single or one of

the capacitor banks are different from each other. Step by step"switching on" operation is more difficult for contactor than capacitor bank.

Because during this operation for capacitor bank, compensated current occurs. For this reas on selecting of suitable contactors the

compensating current must be taken into considera tion for 5 0kVAr and above, and for less than 50 kVAR can be omitted.

IEC60947-4-1, EN60947-4-1

APPLICATION

Fullfill following Standard

Main and auxiliary contacts, coil and auxiliary contact blocks are easily installed and removed. The coils of contact ors are safely co-

ntrolled between 0.8 and 1.1 times of their rated coil voltage. They operate at full performance in the ambient temperature of -5 0

and +55 . The ability of assembling contactors to rails provides a great facility during installation. Th e ingr edient of the material

provides a resistance to an insulation voltage of 1000V.

CONTACT

Contactor damages and effects of these damages:

There can be damages when the contactors are not used according to technical datas and then failures begin to occur at the feeding

system. Reasons of Probable Cancellation of Contactors:

Generally, contactors are the devices, which do not damage easily. If the selection is made correctly and operating conditions are not

out of order, contactor can make millions times opening and closing safely. The reasons of the cancel lat ion and the ir so lutio ns are

given below.

Excessive length of cable of command circuit (coils) can cause some problems. Voltage is low during the long cables and this reason

makes the closing difficultly and over big cross-sectioned cable capacitance obstruct opening. Generally advised cable cross-section

and length are mentioned in catalogues. If the command circuit is longer than the advised value, higher contactor and more lower

coil voltage, resistance or inductive impedance connection should be used.

Dirt or foreign particles in the contactor, hard atmosphere conditions and corrosion can obstruct the closing operation of contactor.

If we face a problem like this, contactor should be cleaned, appropriately. Then th e cir cuit should be checked and modified for a more

protective environment for the contactor. If there is a factor damaging the conduction, it should be removed.

Events that can cause the contactor's, noisy operation is dust and having foreign particles in the air space e tc, un su it ab le voltage

and frequency. Also defect of the nucleus surface because of long time operation. To obstruct all these, we should provide the clea-

rness of the nucleus face and (if needed) coil changing should be made for voltage and frequency.

Changing the coil:

New coil is put on by pulling up screws, which are taking place on both sides of the contactor, separating the upper parts and taking

the coil out off its socket. Much attention should be paid to placing on its spring that at the bottom side, during re-assembling.

CONTACTORS DAMAGES AND REPAIRS

www.dixsen.com M-01

M

Page 2: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

Ref.

CJX1-09N

CJX1-12N

CJX1-16N

CJX1-22N

CJX1-32N

CJX1-45N

CJX1-63N

CJX1-75N

CJX1-85N

CJX1-110N

CJX1-140N

CJX1-170N

CJX1-205N

CJX1-250N

CJX1-300N

CJX1-400N

Type

9

12

16

22

32

38

45

63

75

85

110

140

170

205

250

300

4

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

20

20

30

30

45

45

70

70

90

90

150

150

180

220

300

300

CaseQty.(Pcs)

ItemCode

310094

310124

310164

310224

310324

310454

310634

310754

310854

311104

311404

311704

312054

312504

313004

314004

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

20

20

20

20

10

8

8

4

4

4

4

2

2

1

1

1

Mechanical Interlocking AC Contactor

CJX1 SERIES AC CONTACTOR CJX1 SERIES AC CONTACTOR

Ref. Type

CJX1-09

CJX1-12

CJX1-16

CJX1-22

CJX1-32

CJX1-45

CJX1-63

CJX1-75

CJX1-85

CJX1-110

CJX1-140

CJX1-170

CJX1-205

CJX1-250

CJX1-300

CJX1-400

CJX1-475

Rated current (A)

9

12

16

22

32

45

63

75

85

110

140

170

205

250

300

400

475

Thermal current (A)

20

20

30

30

45

80

80

100

100

160

160

210

210

300

300

400

550

Control Capacity (KW)

380V(AC3)

4

5.5

7.5

11

15

22

30

37

45

55

75

90

110

132

160

200

250

CaseQty.(Pcs)

50

50

50

50

30

16

16

6

6

6

6

4

4

2

2

2

2

ItemCode

310090

310120

310160

310220

310320

310450

310630

310750

310850

311100

311400

311700

312051

312500

313000

314000

314750

A

a

B

b

2- 5 +0.30

C

8

35

78.5

85

88

104(90)

114

108

35+0.31

35+0.31

50+0.31

60+0.37

75+0.37

75+0.37

B

A

ab

C 3 min

45

46

74

CJX1-9/12

CJX1-16/22

CJX1-32

CJX1-45/63

CJX1-75/85

CJX1-110/140

CJX1-170/205

CJX1-250/300

CJX1-400/475

TypeA B C A B

91(114)

102(125)

122(145)

140(163)

150(173)

165(188)

120

135

156

185

205

205

124

142

154

190

200

225

70+0.6

80+0.6

100+0.2

100+0.2

120+0.2

130+0.8

100+0.2

100+0.2

130+0.8

160+0.8

180+0.8

180+0.8

4.8

5.5

6.5

7

9

9

Dimension(mm)

M-02 www.dixsen.com www.dixsen.com M-03

M M

Page 3: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

Ref.

CJX1-09N

CJX1-12N

CJX1-16N

CJX1-22N

CJX1-32N

CJX1-45N

CJX1-63N

CJX1-75N

CJX1-85N

CJX1-110N

CJX1-140N

CJX1-170N

CJX1-205N

CJX1-250N

CJX1-300N

CJX1-400N

Type

9

12

16

22

32

38

45

63

75

85

110

140

170

205

250

300

4

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

20

20

30

30

45

45

70

70

90

90

150

150

180

220

300

300

CaseQty.(Pcs)

ItemCode

310094

310124

310164

310224

310324

310454

310634

310754

310854

311104

311404

311704

312054

312504

313004

314004

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

20

20

20

20

10

8

8

4

4

4

4

2

2

1

1

1

Mechanical Interlocking AC Contactor

CJX1 SERIES AC CONTACTOR CJX1 SERIES AC CONTACTOR

Ref. Type

CJX1-09

CJX1-12

CJX1-16

CJX1-22

CJX1-32

CJX1-45

CJX1-63

CJX1-75

CJX1-85

CJX1-110

CJX1-140

CJX1-170

CJX1-205

CJX1-250

CJX1-300

CJX1-400

CJX1-475

Rated current (A)

9

12

16

22

32

45

63

75

85

110

140

170

205

250

300

400

475

Thermal current (A)

20

20

30

30

45

80

80

100

100

160

160

210

210

300

300

400

550

Control Capacity (KW)

380V(AC3)

4

5.5

7.5

11

15

22

30

37

45

55

75

90

110

132

160

200

250

CaseQty.(Pcs)

50

50

50

50

30

16

16

6

6

6

6

4

4

2

2

2

2

ItemCode

310090

310120

310160

310220

310320

310450

310630

310750

310850

311100

311400

311700

312051

312500

313000

314000

314750

A

a

B

b

2- 5 +0.30

C

8

35

78.5

85

88

104(90)

114

108

35+0.31

35+0.31

50+0.31

60+0.37

75+0.37

75+0.37

B

A

a

b

C 3 min

45

46

74

CJX1-9/12

CJX1-16/22

CJX1-32

CJX1-45/63

CJX1-75/85

CJX1-110/140

CJX1-170/205

CJX1-250/300

CJX1-400/475

TypeA B C A B

91(114)

102(125)

122(145)

140(163)

150(173)

165(188)

120

135

156

185

205

205

124

142

154

190

200

225

70+0.6

80+0.6

100+0.2

100+0.2

120+0.2

130+0.8

100+0.2

100+0.2

130+0.8

160+0.8

180+0.8

180+0.8

4.8

5.5

6.5

7

9

9

Dimension(mm)

M-02 www.dixsen.com www.dixsen.com M-03

M M

Page 4: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

SQ

P

6.5

R

A fGa

L

C

P Q1

11

.5

Ha

B1

N MX

1

B

X1

CJX2-115~630

Type

CJX2-F115

CJX2-F150

CJX2-F170

CJX2-F205

CJX2-F245

CJX2-F300

CJX2-F410

CJX2-F475

CJX2-F620

A

158

158

158

168.5

168.5

213

213

233

309

B

120

120

120

174

197

206

206

238

304

C

132

132

132

181

181

219

219

232

255

B1

158

158

158

137

137

145

209

209

280

P

35

35

35

40

48

48

48

55

80

Q

60

60

60

69

69

91

91

108

140

S

17

17

17

20

25

25

25

30

40

Q1

25

25

25

59.4

51.5

74

74

77

89

M

134

134

134

154

172

181

181

208

264

N

96.2

96.2

96.2

127

127

158

158

172

202

L

75

75

75

113.5

113.5

145

145

146

155

M6

M6

M6

M8

M10

M10

M10

M10

M12

Ga

-

-

-

80

80

80

80

80

80

Ha

-

-

-

120-106

120-106

120-106

120-106

180

180

Dimension(mm)

115

115

150

150

185

185

225

225

265

265

330

330

400

400

500

500

630

630

780

780

80

80

100

100

110

110

129

129

160

160

220

220

280

280

335

335

450

450

475

475

55

55

75

75

90

90

110

110

132

132

160

160

200

200

250

250

335

335

400

400

CJX2-F115/3P

CJX2-F115/4P

CJX2-F150/3P

CJX2-F150/4P

CJX2-F185/3P

CJX2-F185/4P

CJX2-F225/3P

CJX2-F225/4P

CJX2-F265/3P

CJX2-F265/4P

CJX2-F330/3P

CJX2-F330/4P

CJX2-F400/3P

CJX2-F400/4P

CJX2-F500/3P

CJX2-F500/4P

CJX2-F630/3P

CJX2-F630/4P

CJX2-F780/3P

CJX2-F780/4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

4

4

4

4

4

2

2

2

2

2

2

2

2

2

2

2

1

1

1

1

361153

361154

361503

361504

361853

361854

362253

362254

362653

362654

363303

363304

364003

364004

365003

365004

366303

366304

367803

367804

Ref.

660V(AC3)

CaseQty.(Pcs)

ItemCode

Type Rated current (A)

No. Of Pole

380V(AC3)

Control Capacity (KW)

CJX2 SERIES AC CONTACTORCJX2 SERIES AC CONTACTOR

Ref.

CJX2-09

CJX2-12

CJX2-18

CJX2-25

CJX2-32

CJX2-40

CJX2-50

CJX2-65

CJX2-80

CJX2-95

CJX2-115

CJX2-150

CJX2-170

CJX2-205

CJX2-245

CJX2-300

CJX2-410

CJX2-475

CJX2-620

Type

09

12

18

25

32

40

50

65

80

95

115

150

170

205

245

300

410

475

620

4

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

220

265

335

Power of Control

Motor(KW)380V(AC3)

20

20

32

40

50

60

80

80

125

125

200

250

250

275

315

400

500

700

1000

CaseQty.(Pcs)

50

50

50

50

50

20

20

20

10

10

4

4

4

4

2

2

2

2

1

ItemCode

320009

320012

320018

320025

320032

320041

320050

320065

320080

320095

320115

320150

320170

320205

320245

320300

320410

320475

320620

Rated current (A)

Thermal current (A)

Type A B C D A B

CJX2-09/12

CJX2-18

CJX2-25

CJX2-32

CJX2-40/65

CJX2-80/95

47

47

57

57

77

87

76

76

86

86

129

129

82

87

95

100

116

127

113

118

126

131

145

175

34/35

34/35

40

40

40

40

50/60

50/60

48

48

100/110

100/110

4.5

4.5

4.5

4.5

6.5

6.5

Dimension(mm)

C

D

B

CJX2-40~95

D

B

C a

b

A

2-

A

b

3-

CJX2-09~12

M-04 www.dixsen.com www.dixsen.com M-05

M M

Page 5: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

SQ

P

6.5

R

A fGa

L

C

P Q1

11

.5

Ha

B1

N MX

1

B

X1

CJX2-115~630

Type

CJX2-F115

CJX2-F150

CJX2-F170

CJX2-F205

CJX2-F245

CJX2-F300

CJX2-F410

CJX2-F475

CJX2-F620

A

158

158

158

168.5

168.5

213

213

233

309

B

120

120

120

174

197

206

206

238

304

C

132

132

132

181

181

219

219

232

255

B1

158

158

158

137

137

145

209

209

280

P

35

35

35

40

48

48

48

55

80

Q

60

60

60

69

69

91

91

108

140

S

17

17

17

20

25

25

25

30

40

Q1

25

25

25

59.4

51.5

74

74

77

89

M

134

134

134

154

172

181

181

208

264

N

96.2

96.2

96.2

127

127

158

158

172

202

L

75

75

75

113.5

113.5

145

145

146

155

M6

M6

M6

M8

M10

M10

M10

M10

M12

Ga

-

-

-

80

80

80

80

80

80

Ha

-

-

-

120-106

120-106

120-106

120-106

180

180

Dimension(mm)

115

115

150

150

185

185

225

225

265

265

330

330

400

400

500

500

630

630

780

780

80

80

100

100

110

110

129

129

160

160

220

220

280

280

335

335

450

450

475

475

55

55

75

75

90

90

110

110

132

132

160

160

200

200

250

250

335

335

400

400

CJX2-F115/3P

CJX2-F115/4P

CJX2-F150/3P

CJX2-F150/4P

CJX2-F185/3P

CJX2-F185/4P

CJX2-F225/3P

CJX2-F225/4P

CJX2-F265/3P

CJX2-F265/4P

CJX2-F330/3P

CJX2-F330/4P

CJX2-F400/3P

CJX2-F400/4P

CJX2-F500/3P

CJX2-F500/4P

CJX2-F630/3P

CJX2-F630/4P

CJX2-F780/3P

CJX2-F780/4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

4

4

4

4

4

2

2

2

2

2

2

2

2

2

2

2

1

1

1

1

361153

361154

361503

361504

361853

361854

362253

362254

362653

362654

363303

363304

364003

364004

365003

365004

366303

366304

367803

367804

Ref.

660V(AC3)

CaseQty.(Pcs)

ItemCode

Type Rated current (A)

No. Of Pole

380V(AC3)

Control Capacity (KW)

CJX2 SERIES AC CONTACTORCJX2 SERIES AC CONTACTOR

Ref.

CJX2-09

CJX2-12

CJX2-18

CJX2-25

CJX2-32

CJX2-40

CJX2-50

CJX2-65

CJX2-80

CJX2-95

CJX2-115

CJX2-150

CJX2-170

CJX2-205

CJX2-245

CJX2-300

CJX2-410

CJX2-475

CJX2-620

Type

09

12

18

25

32

40

50

65

80

95

115

150

170

205

245

300

410

475

620

4

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

220

265

335

Power of Control

Motor(KW)380V(AC3)

20

20

32

40

50

60

80

80

125

125

200

250

250

275

315

400

500

700

1000

CaseQty.(Pcs)

50

50

50

50

50

20

20

20

10

10

4

4

4

4

2

2

2

2

1

ItemCode

320009

320012

320018

320025

320032

320041

320050

320065

320080

320095

320115

320150

320170

320205

320245

320300

320410

320475

320620

Rated current (A)

Thermal current (A)

Type A B C D A B

CJX2-09/12

CJX2-18

CJX2-25

CJX2-32

CJX2-40/65

CJX2-80/95

47

47

57

57

77

87

76

76

86

86

129

129

82

87

95

100

116

127

113

118

126

131

145

175

34/35

34/35

40

40

40

40

50/60

50/60

48

48

100/110

100/110

4.5

4.5

4.5

4.5

6.5

6.5

Dimension(mm)

C

D

B

CJX2-40~95

D

B

C a

b

A

2-

A

b

3-

CJX2-09~12

M-04 www.dixsen.com www.dixsen.com M-05

M M

Page 6: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

CJX2N SERIES AC CONTACTOR

C

B

Ref. Type

CJX2N-09

CJX2N-12

CJX2N-18

CJX2N-25

CJX2N-32

CJX2N-38

CJX2N-40

CJX2N-50

CJX2N-65

CJX2N-80

CJX2N-95

09

12

18

25

32

38

40

50

65

80

95

25

25

32

40

50

50

60

80

80

125

125

4

5.5

7.5

11

15

18.5

18.5

22

30

37

45

50

50

50

50

50

50

10

10

10

10

10

CaseQty.(Pcs)

320090

320120

320180

320250

320320

320380

320400

320500

320650

320800

320950

ItemCode

II

II

-09 -12 -18 -25 -32 -38 -40 -50 -65 -80 -95 -115 -150

B

C

76.6

87

76.6

87

76.6

94

76.6

87

76.6

94

76.6

94

127

116

127

116

127

116

127

123.8

127

123.8

158

132

158

132

Dimensions(mm)

CJX2N

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

AC CONTACTOR ACCESSORIES

LA1-D10

LA1-D01

LA1-D11

LA1-D20

LA1-D02

LA1-D40

LA1-D31

LA1-D22

LA1-D13

LA1-D04

LA2-DT0

LA2-DT2

LA2-DT4

LA2-DS2

LA3-DT0

LA3-DT2

LA3-DT4

0.1~3S

0.1~30S

10~180S

1~30S

0.1~3S

0.1~30S

10~180S

LA8-D11

LA8-D20

-

-

-

-

-

CJX2-F115~150

CJX2-F185~225

CJX2-F265~330

CJX2-F400

CJX2-F500

CJX2-F630

CJX2-F780

LX1-FF

LX1-FG

LX1-FH

LX1-FJ

LX1-FK

LX1-FL

LX1-FX

LX1-D2

LX1-D4

LX1-D6

CJX2-09~18

CJX2-25~32

CJX2-40~95

121401

121402

121410

121411

121420

121404

121413

121422

121431

121440

122420

122422

122424

122492

123420

123422

123424

128411

128420

141042

141044

141046

141606

141607

141608

141610

141611

141612

141621

NO

NC

-

-

-

-

-

-

-

NO+NC

2NO

2NC

4NO

3NO+NC

2NO+2NC

NO+3NC

4NC

NO+NC

2NO

ContactDelay time CaseQty.(Pcs)

ItemCode

TypeRef.

500

500

300

300

300

300

300

300

300

300

-

-

100

100

100

100

100

100

100

250

150

100

30

30

30

20

20

20

20

NO+NC

NO+NC

NO+NC

NO+NC

NO+NC

NO+NC

NO+NC

Auxiliary Contact Block & Bobbin

-

-

-

-

-

-

-

-

-

-

M-06 www.dixsen.com www.dixsen.com M-07

M M

Page 7: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

CJX2N SERIES AC CONTACTOR

C

B

Ref. Type

CJX2N-09

CJX2N-12

CJX2N-18

CJX2N-25

CJX2N-32

CJX2N-38

CJX2N-40

CJX2N-50

CJX2N-65

CJX2N-80

CJX2N-95

09

12

18

25

32

38

40

50

65

80

95

25

25

32

40

50

50

60

80

80

125

125

4

5.5

7.5

11

15

18.5

18.5

22

30

37

45

50

50

50

50

50

50

10

10

10

10

10

CaseQty.(Pcs)

320090

320120

320180

320250

320320

320380

320400

320500

320650

320800

320950

ItemCode

II

II

-09 -12 -18 -25 -32 -38 -40 -50 -65 -80 -95 -115 -150

B

C

76.6

87

76.6

87

76.6

94

76.6

87

76.6

94

76.6

94

127

116

127

116

127

116

127

123.8

127

123.8

158

132

158

132

Dimensions(mm)

CJX2N

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

AC CONTACTOR ACCESSORIES

LA1-D10

LA1-D01

LA1-D11

LA1-D20

LA1-D02

LA1-D40

LA1-D31

LA1-D22

LA1-D13

LA1-D04

LA2-DT0

LA2-DT2

LA2-DT4

LA2-DS2

LA3-DT0

LA3-DT2

LA3-DT4

0.1~3S

0.1~30S

10~180S

1~30S

0.1~3S

0.1~30S

10~180S

LA8-D11

LA8-D20

-

-

-

-

-

CJX2-F115~150

CJX2-F185~225

CJX2-F265~330

CJX2-F400

CJX2-F500

CJX2-F630

CJX2-F780

LX1-FF

LX1-FG

LX1-FH

LX1-FJ

LX1-FK

LX1-FL

LX1-FX

LX1-D2

LX1-D4

LX1-D6

CJX2-09~18

CJX2-25~32

CJX2-40~95

121401

121402

121410

121411

121420

121404

121413

121422

121431

121440

122420

122422

122424

122492

123420

123422

123424

128411

128420

141042

141044

141046

141606

141607

141608

141610

141611

141612

141621

NO

NC

-

-

-

-

-

-

-

NO+NC

2NO

2NC

4NO

3NO+NC

2NO+2NC

NO+3NC

4NC

NO+NC

2NO

ContactDelay time CaseQty.(Pcs)

ItemCode

TypeRef.

500

500

300

300

300

300

300

300

300

300

-

-

100

100

100

100

100

100

100

250

150

100

30

30

30

20

20

20

20

NO+NC

NO+NC

NO+NC

NO+NC

NO+NC

NO+NC

NO+NC

Auxiliary Contact Block & Bobbin

-

-

-

-

-

-

-

-

-

-

M-06 www.dixsen.com www.dixsen.com M-07

M M

Page 8: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

Ref.

115

115

150

150

185

185

225

225

265

265

330

330

400

400

500

500

630

630

780

780

55

55

75

75

90

90

110

110

132

132

160

160

200

200

250

250

335

335

400

400

CaseQty.(Pcs)

ItemCode

CJX2-F115N/3P

CJX2-F115N/4P

CJX2-F150N/3P

CJX2-F150N/4P

CJX2-F185N/3P

CJX2-F185N/4P

CJX2-F225N/3P

CJX2-F225N/4P

CJX2-F265N/3P

CJX2-F265N/4P

CJX2-F330N/3P

CJX2-F330N/4P

CJX2-F400N/3P

CJX2-F400N/4P

CJX2-F500N/3P

CJX2-F500N/4P

CJX2-F630N/3P

CJX2-F630N/4P

CJX2-F780N/3P

CJX2-F780N/4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

311543

311544

315043

315044

318543

318544

322543

322544

326543

326544

333043

333044

340043

340044

350043

350044

363043

363044

378043

378044

Type Rated current (A)

No. ofPole

Control Capacity (KW)

380V(AC3)

CJX2-F MECHANICAL INTERLOCKING AC CONTACTORCJX2 MECHANICAL INTERLOCKING AC CONTACTOR

Ref. CaseQty.(Pcs)

ItemCode

Type

340094

340124

340184

340254

340344

340404

340504

340654

340804

340954

CJX2-09N

CJX2-12N

CJX2-18N

CJX2-25N

CJX2-32N

CJX2-40N

CJX2-50N

CJX2-65N

CJX2-80N

CJX2-95N

09

12

18

25

32

40

50

65

80

95

20

20

32

40

50

60

80

80

125

125

4

5.5

7.5

11

15

18.5

22

30

37

45

30

30

30

20

20

12

12

12

12

12

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

CJX2-09N~38N CJX2-80N~95N CJX2-40N~65N

Type

CJX2-09N, 12N

CJX2-18N

CJX2-25N

CJX2-32N,38N

A

105

106

127

127

B

74

74

84

84

C

84

92

99

117

E1(3P)

7

8

9

10

E2(4P)

6

-

7

-

G

95

95

111

111

Type

CJX2-40N, 50N, 55N (3pole)

CJX2-40N, 65N (4 pole)

a

165

a

182

b

127

b

127

c

142

c

133

e1

5

e2

11

GG

50

GG

57

1

90

1

97

Type

CJX2N-80N, 95N (3pole)

CJ2N-80N (4pole)

a

182

a

207

b

127

b

127

c

158

c

158

e1

13

e2

20

GG

57

GG

71

1

90

1

11

OUTLINE DIMENSION

M-08 www.dixsen.com www.dixsen.com M-09

M M

Page 9: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

Ref.

115

115

150

150

185

185

225

225

265

265

330

330

400

400

500

500

630

630

780

780

55

55

75

75

90

90

110

110

132

132

160

160

200

200

250

250

335

335

400

400

CaseQty.(Pcs)

ItemCode

CJX2-F115N/3P

CJX2-F115N/4P

CJX2-F150N/3P

CJX2-F150N/4P

CJX2-F185N/3P

CJX2-F185N/4P

CJX2-F225N/3P

CJX2-F225N/4P

CJX2-F265N/3P

CJX2-F265N/4P

CJX2-F330N/3P

CJX2-F330N/4P

CJX2-F400N/3P

CJX2-F400N/4P

CJX2-F500N/3P

CJX2-F500N/4P

CJX2-F630N/3P

CJX2-F630N/4P

CJX2-F780N/3P

CJX2-F780N/4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

3P

4P

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

311543

311544

315043

315044

318543

318544

322543

322544

326543

326544

333043

333044

340043

340044

350043

350044

363043

363044

378043

378044

Type Rated current (A)

No. ofPole

Control Capacity (KW)

380V(AC3)

CJX2-F MECHANICAL INTERLOCKING AC CONTACTORCJX2 MECHANICAL INTERLOCKING AC CONTACTOR

Ref. CaseQty.(Pcs)

ItemCode

Type

340094

340124

340184

340254

340344

340404

340504

340654

340804

340954

CJX2-09N

CJX2-12N

CJX2-18N

CJX2-25N

CJX2-32N

CJX2-40N

CJX2-50N

CJX2-65N

CJX2-80N

CJX2-95N

09

12

18

25

32

40

50

65

80

95

20

20

32

40

50

60

80

80

125

125

4

5.5

7.5

11

15

18.5

22

30

37

45

30

30

30

20

20

12

12

12

12

12

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

CJX2-09N~38N CJX2-80N~95N CJX2-40N~65N

Type

CJX2-09N, 12N

CJX2-18N

CJX2-25N

CJX2-32N,38N

A

105

106

127

127

B

74

74

84

84

C

84

92

99

117

E1(3P)

7

8

9

10

E2(4P)

6

-

7

-

G

95

95

111

111

Type

CJX2-40N, 50N, 55N (3pole)

CJX2-40N, 65N (4 pole)

a

165

a

182

b

127

b

127

c

142

c

133

e1

5

e2

11

GG

50

GG

57

1

90

1

97

Type

CJX2N-80N, 95N (3pole)

CJ2N-80N (4pole)

a

182

a

207

b

127

b

127

c

158

c

158

e1

13

e2

20

GG

57

GG

71

1

90

1

11

OUTLINE DIMENSION

M-08 www.dixsen.com www.dixsen.com M-09

M M

Page 10: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

Ref.

2.2

4.0

5.5

6

9

12

16

20

20

CJX2-K06N

CJX2-K09N

CJX2-K12N

CaseQty.(Pcs)

ItemCode

311064

311094

311124

50

50

50

Mechanical interlocking AC contractor

Type

2.2

4.0

5.5

6

9

12

16

20

20

311060

311090

311120

100

100

100

CJX2-K06

CJX2-K09

CJX2-K12

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

Ref. Type Power of Control Motor(KW)380V(AC3)

CJX-00M

CJX-00AM

CJX-0M

CJX-0AM

CJX-1M

CJX-01AM

CJX-02AM

CJX-2AM

CJX-3M

9

12

18

25

32

40

50

63

72

20

20

35

35

55

55

90

90

100

4

5.5

7.5

11

15

18.5

22

22

30

CaseQty.(Pcs)

ItemCode

300100

300021

305000

305100

301000

301200

300200

302100

303000

60

60

60

60

40

40

20

20

Rated current (A)

Thermal current (A)

CJX2-K SERIES AC CONTACTORCJX2-F AC CONTACTOR

Type

CJX2-F115N/3P

CJX2-F115N/4P

CJX2-F150N/3P

CJX2-F150N/4P

CJX2-F185N/3P

CJX2-F185N/4P

CJX2-F125N/3P

CJX2-F125N/4P

CJX2-F165N/3P

CJX2-F165N/4P

CJX2-F330N/3P

CJX2-F330N/4P

CJX2-F400N/3P

CJX2-F400N/4P

CJX2-F500N/3P

CJX2-F630N/3P

CJX2-F630N/4P

A

350

425

350

425

350

430

350

430

450

546

450

546

485

485

485

650

810

J

71

105

71

105

78

114

78

118

109

157

124

166

157

157

156

139

139

P1

77

77

71

71

71

71

55

54

96

100

112

107

110

107

115

140

137

F

131

131

131

131

130

130

130

130

147

147

147

147

146

146

150

181

181

B

330

370

330

370

330

370

330

370

428

485

428

485

460

485

460

625

780

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

8.5

8.5

8.5

10.5

10.5

C

182

182

182

182

193

193

193

193

225

225

232.5

232.5

232.5

232.5

245.5

268.5

268.5

Level intallment

Stand intallment

CJX2-F115N~150N

Type

CJX2-F115N/F150N

CJX2-F185N/F225N

CJX2-F265N

CJX2-F330N

CJX2-F400N

CJX2-F500N

CJX2-F630N

200

220

250

260

280

300

380

310

310

380

380

380

380

380

80

100

130

60

100

120

200

190

190

260

200

200

200

200

Min Max

H

Min Max

H

CJX2-F185N~225N

M-10 www.dixsen.com www.dixsen.com M-11

M M

Page 11: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

Ref.

2.2

4.0

5.5

6

9

12

16

20

20

CJX2-K06N

CJX2-K09N

CJX2-K12N

CaseQty.(Pcs)

ItemCode

311064

311094

311124

50

50

50

Mechanical interlocking AC contractor

Type

2.2

4.0

5.5

6

9

12

16

20

20

311060

311090

311120

100

100

100

CJX2-K06

CJX2-K09

CJX2-K12

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

Ref. Type Power of Control Motor(KW)380V(AC3)

CJX-00M

CJX-00AM

CJX-0M

CJX-0AM

CJX-1M

CJX-01AM

CJX-02AM

CJX-2AM

CJX-3M

9

12

18

25

32

40

50

63

72

20

20

35

35

55

55

90

90

100

4

5.5

7.5

11

15

18.5

22

22

30

CaseQty.(Pcs)

ItemCode

300100

300021

305000

305100

301000

301200

300200

302100

303000

60

60

60

60

40

40

20

20

Rated current (A)

Thermal current (A)

CJX2-K SERIES AC CONTACTORCJX2-F AC CONTACTOR

Type

CJX2-F115N/3P

CJX2-F115N/4P

CJX2-F150N/3P

CJX2-F150N/4P

CJX2-F185N/3P

CJX2-F185N/4P

CJX2-F125N/3P

CJX2-F125N/4P

CJX2-F165N/3P

CJX2-F165N/4P

CJX2-F330N/3P

CJX2-F330N/4P

CJX2-F400N/3P

CJX2-F400N/4P

CJX2-F500N/3P

CJX2-F630N/3P

CJX2-F630N/4P

A

350

425

350

425

350

430

350

430

450

546

450

546

485

485

485

650

810

J

71

105

71

105

78

114

78

118

109

157

124

166

157

157

156

139

139

P1

77

77

71

71

71

71

55

54

96

100

112

107

110

107

115

140

137

F

131

131

131

131

130

130

130

130

147

147

147

147

146

146

150

181

181

B

330

370

330

370

330

370

330

370

428

485

428

485

460

485

460

625

780

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

6.5

8.5

8.5

8.5

10.5

10.5

C

182

182

182

182

193

193

193

193

225

225

232.5

232.5

232.5

232.5

245.5

268.5

268.5

Level intallment

Stand intallment

CJX2-F115N~150N

Type

CJX2-F115N/F150N

CJX2-F185N/F225N

CJX2-F265N

CJX2-F330N

CJX2-F400N

CJX2-F500N

CJX2-F630N

200

220

250

260

280

300

380

310

310

380

380

380

380

380

80

100

130

60

100

120

200

190

190

260

200

200

200

200

Min Max

H

Min Max

H

CJX2-F185N~225N

M-10 www.dixsen.com www.dixsen.com M-11

M M

Page 12: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

CJ19 SERIES AC CONTACTOR

CJ

CJ

CJ

CJ

CJ

19-25

19-32

19-43

19-63

19-95

404040

575757

48

48

48

50

.60

50

.60

50

.60

12

5m

ax

12

5m

ax

12

5m

ax

A B C D E F

80

90

90

132

135

47

58

58

79

87

124

134

136

150

158

76

86

86

-

-

34/35

40

40

-

-

50/60

48

48

-

-

Type Dimensions(mm)

Ref.CaseQty.(Pcs)

TypeItemCode

CJ19-25

CJ19-32

CJ19-43

CJ19-63

CJ19-95

18

23

29

43

63

12

18

20

30

40

310925

310932

310943

310963

310995

Control Capacity (KW)

Rated current (A)380V(AC3)

40

32

32

20

20

WHY CAPACITOR SWITCHING CONTACTOR?

As it is known, when the capacitor starts to operate, they cause a high frequency between 1-15 kHz. And a current that is 180 time higher

than rated current for very short time period. Shock inductance is to be fixed to each phase to lim it this current. But practically this

type of operation is difficult. That is why capacitor switching contactors are used and for this reason the life-time of contactors increase

100% in comparision with normal contactor. 09

12

18

25

32

40

50

65

80

95

CJX2-Z09

CJX2-Z12

CJX2-Z18

CJX2-Z25

CJX2-Z32

CJX2-Z40

CJX2-Z50

CJX2-Z65

CJX2-Z80

CJX2-Z95

25

25

32

40

50

60

80

80

125

125

4

5.5

7.5

11

15

18.5

22

30

37

45

360096

360126

360186

360256

360326

360406

360506

360656

360806

360956

30

30

30

30

30

10

10

10

10

10

Ref. CaseQty.(Pcs)

ItemCode

Type Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

CJX2-Z SERIES AC CONTACTORS

CJX2-09Z-12Z

CJX2-18Z

CJX2-25Z

CJX2-32Z

CJX2-4011Z~6511Z

CJX2-4004/4008Z~6504/6508Z

CJX2-8011Z~9511Z

CJX2-09Z~12Z

CJX2-8004/8008Z~9504/9508Z

47

47

47

57

57

77

84

87

96

76

76

76

86

86

129

129

129

129

82(116)

82(116)

87(122)

95(131)

100(138)

116(173)

116(173)

127(188)

127(183)

120.5(154.5)

120.5(154.5)

125.5(160.5)

133.5(169.5)

138.5(176.5)

154.5(211.5)

154.5(211.5)

165.5(226.5)

160.5(221.5)

140.5(174.5)

140.5(174.5)

145.5(185.5)

153.5(189.5)

158.5(196.5)

174.5(231.5)

174.5(231.5)

185.5(246.5)

180.5(241.5)

34/35

34/35

34/35

40

40

40

40

40

40

50/60

50/60

50/60

48

48

100/110

100/110

100/110

100/110

4.5

4.5

4.5

4.5

4.5

6.5

6.5

6.5

6.5

60(95)

60(95)

61(96)

70(107)

71.6(120)

78(135)

78(135)

83(140)

83(140)

105

105

11.3

13.2

14.5

20

20

23.5

23.5

8.6

8.6

10.4

11.7

13

8.6

8.6

12

12

C D E a b L P SA B

Dimension(mm)

CJX2-09-32Z CJX2-40-95Z

M-12 www.dixsen.com www.dixsen.com M-13

M M

Page 13: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

CJ19 SERIES AC CONTACTOR

CJ

CJ

CJ

CJ

CJ

19-25

19-32

19-43

19-63

19-95

404040

575757

48

48

48

50

.60

50

.60

50

.60

12

5m

ax

12

5m

ax

12

5m

ax

A B C D E F

80

90

90

132

135

47

58

58

79

87

124

134

136

150

158

76

86

86

-

-

34/35

40

40

-

-

50/60

48

48

-

-

Type Dimensions(mm)

Ref.CaseQty.(Pcs)

TypeItemCode

CJ19-25

CJ19-32

CJ19-43

CJ19-63

CJ19-95

18

23

29

43

63

12

18

20

30

40

310925

310932

310943

310963

310995

Control Capacity (KW)

Rated current (A)380V(AC3)

40

32

32

20

20

WHY CAPACITOR SWITCHING CONTACTOR?

As it is known, when the capacitor starts to operate, they cause a high frequency between 1-15 kHz. And a current that is 180 time higher

than rated current for very short time period. Shock inductance is to be fixed to each phase to lim it this current. But practically this

type of operation is difficult. That is why capacitor switching contactors are used and for this reason the life-time of contactors increase

100% in comparision with normal contactor. 09

12

18

25

32

40

50

65

80

95

CJX2-Z09

CJX2-Z12

CJX2-Z18

CJX2-Z25

CJX2-Z32

CJX2-Z40

CJX2-Z50

CJX2-Z65

CJX2-Z80

CJX2-Z95

25

25

32

40

50

60

80

80

125

125

4

5.5

7.5

11

15

18.5

22

30

37

45

360096

360126

360186

360256

360326

360406

360506

360656

360806

360956

30

30

30

30

30

10

10

10

10

10

Ref. CaseQty.(Pcs)

ItemCode

Type Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

CJX2-Z SERIES AC CONTACTORS

CJX2-09Z-12Z

CJX2-18Z

CJX2-25Z

CJX2-32Z

CJX2-4011Z~6511Z

CJX2-4004/4008Z~6504/6508Z

CJX2-8011Z~9511Z

CJX2-09Z~12Z

CJX2-8004/8008Z~9504/9508Z

47

47

47

57

57

77

84

87

96

76

76

76

86

86

129

129

129

129

82(116)

82(116)

87(122)

95(131)

100(138)

116(173)

116(173)

127(188)

127(183)

120.5(154.5)

120.5(154.5)

125.5(160.5)

133.5(169.5)

138.5(176.5)

154.5(211.5)

154.5(211.5)

165.5(226.5)

160.5(221.5)

140.5(174.5)

140.5(174.5)

145.5(185.5)

153.5(189.5)

158.5(196.5)

174.5(231.5)

174.5(231.5)

185.5(246.5)

180.5(241.5)

34/35

34/35

34/35

40

40

40

40

40

40

50/60

50/60

50/60

48

48

100/110

100/110

100/110

100/110

4.5

4.5

4.5

4.5

4.5

6.5

6.5

6.5

6.5

60(95)

60(95)

61(96)

70(107)

71.6(120)

78(135)

78(135)

83(140)

83(140)

105

105

11.3

13.2

14.5

20

20

23.5

23.5

8.6

8.6

10.4

11.7

13

8.6

8.6

12

12

C D E a b L P SA B

Dimension(mm)

CJX2-09-32Z CJX2-40-95Z

M-12 www.dixsen.com www.dixsen.com M-13

M M

Page 14: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

CJX5 SERIES AC CONTACTOR

Ref. CaseQty.(Pcs)

ItemCode

Type

20

20

25

32

50

60

80

100

110

135

150

150

9

12

18

22

32

40

50

65

75

85

100

125

4

5.5

7.5

11

15

18.5

22

30

37

45

55

60

315009

315012

315018

315022

315032

315040

315050

315065

315075

315085

315100

315115

60

60

60

60

40

40

20

20

20

20

CJX5-09

CJX5-12

CJX5-18

CJX5-22

CJX5-32

CJX5-40

CJX5-50

CJX5-65

CJX5-75

CJX5-85

CJX5-100

CJX5-125

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

CJX5-9~22

CJX5-32~40

CJX5-50~85

CJX4 SERIES AC CONTACTOR

Ref. Case

Qty.

(Pcs)

Item

Code

Type

CJX4-10

CJX4-11

CJX4-12

CJX4-18

CJX4-20

CJX4-21

CJX4-25

CJX4-35

CJX4-50

CJX4-65

CJX4-80

CJX4-95

20

20

25

25

32

32

50

60

80

100

135

135

9

12

12

16

22

22

30

40

50

62

85

105

3.3

4

4

7.5

10

10

14

20

22

30

45

55

60

60

60

60

40

40

40

40

20

20

16

16

314010

314011

314012

314018

314020

314021

314025

314035

314050

314065

314080

314095

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

M-14 www.dixsen.com www.dixsen.com M-15

M M

Page 15: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

CJX5 SERIES AC CONTACTOR

Ref. CaseQty.(Pcs)

ItemCode

Type

20

20

25

32

50

60

80

100

110

135

150

150

9

12

18

22

32

40

50

65

75

85

100

125

4

5.5

7.5

11

15

18.5

22

30

37

45

55

60

315009

315012

315018

315022

315032

315040

315050

315065

315075

315085

315100

315115

60

60

60

60

40

40

20

20

20

20

CJX5-09

CJX5-12

CJX5-18

CJX5-22

CJX5-32

CJX5-40

CJX5-50

CJX5-65

CJX5-75

CJX5-85

CJX5-100

CJX5-125

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

CJX5-9~22

CJX5-32~40

CJX5-50~85

CJX4 SERIES AC CONTACTOR

Ref. Case

Qty.

(Pcs)

Item

Code

Type

CJX4-10

CJX4-11

CJX4-12

CJX4-18

CJX4-20

CJX4-21

CJX4-25

CJX4-35

CJX4-50

CJX4-65

CJX4-80

CJX4-95

20

20

25

25

32

32

50

60

80

100

135

135

9

12

12

16

22

22

30

40

50

62

85

105

3.3

4

4

7.5

10

10

14

20

22

30

45

55

60

60

60

60

40

40

40

40

20

20

16

16

314010

314011

314012

314018

314020

314021

314025

314035

314050

314065

314080

314095

Rated current (A)

Thermal current (A)

Control Capacity (KW)

380V(AC3)

M-14 www.dixsen.com www.dixsen.com M-15

M M

Page 16: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

ApprovalType Case

Qty.

(Pcs)

Item

code

TERMINALS SELECTION

There are three sorts of terminals for 1P and 2P of DCK3, please see right photos.

1. Binder Head Screw (code W): pressing connects

2.Screw with square washer( code Y): pressing connects

3.Box Lug (code N): quick connects

Necessary information required for order : Please indicate the terminals type on ordering.

BinderHead Screw (W)

Screw withsquare washer (Y)

Box Lug (N)

Ref.

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

20

20

20

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

24

120

240

cULus

cULus

-

-

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

40

40

40

40

40

40

40

40

40

40

40

40

43209024

43209120

43209240

43259024

43259120

43259240

43309024

43309120

43309240

43409024

43409120

43409240

DCK3-20/2 24V(2PCS)

DCK3-20/2 120V(2PCD)

DCK3-20/2 240V(2PCS)

DCK3-25/2 24V(2PCS)

DCK3-25/2 120V(2PCS)

DCK3-25/2 240V(2PCS)

DCK3-30/2 24V(2PCS)

DCK3-30/2 120V(2PCS)

DCK3-30/2 240V(2PCS)

DCK3-40/2 24V(2PCS)

DCK3-40/2 120V(2PCS)

DCK3-40/2 240V(2PCS)

DEFINITE PURPOSE AC CONTACTOR SERIES

GENERAL

DCK3 Series definite purpose AC contactor are designed for use in refrigeration, air conditionin g, and electric heating syst-

ems . Power connections can be made with either screw terminals with quick onnects or l ug terminals with quick connects. Standard

According:

GB14048.4, UL508, IEC60947-4.

DCK3 Series (1P & 2P) Specification

DCK3-20/1 24V

DCK3-20/1 120V

DCK3-20/1 240V

DCK3-25/1 24V

DCK3-25/1 120V

DCK3-25/1 240V

DCK3-30/1 24V

DCK3-30/1 120V

DCK3-30/1 240V

1P

1P

1P

1P

1P

1P

1P

1P

1P

20

20

20

25

25

25

30

30

30

24

120

240

24

120

240

24

120

240

-

-

-

-

-

-

cULus

cULus

cULus

40

40

40

40

40

40

40

40

40

DCK3-20/2 24V(2P)

DCK3-20/2 120V(2P)

DCK3-20/2 240V(2P)

DCK3-25/2 24V(2P)

DCK3-25/2 120V(2P)

DCK3-25/2 240V(2P)

DCK3-30/2 24V(2P)

DCK3-30/2 120V(2P)

DCK3-30/2 240V(2P)

DCK3-40/2 24V(2P)

DCK3-40/2 120V(2P)

DCK3-40/2 240V(2P)

20

20

20

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

24

120

240

20

20

20

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

24

120

240

cULus

cULus

-

-

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

40

40

40

40

40

40

40

40

40

40

40

40

No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

ApprovalType Case

Qty.(Pcs)

Item

code

cULus

cULus

-

-

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

40

40

40

40

40

40

40

40

40

40

40

40

43201024

43201120

43201240

43251024

43251120

43251240

43301024

43301120

43301240

43202024

43202120

43202240

43252024

43252120

43252240

43302024

43302120

43302240

43402024

43402120

43402240

43206024

43206120

43206240

43256024

43256120

43256240

43306024

43306120

43306240

43406024

43406120

43406240

Ref.

DCK3-20/2 24V(2PC)

DCK3-20/2 120V(2PC)

DCK3-20/2 240V(2PC)

DCK3-25/2 24V(2PC)

DCK3-25/2 120V(2PC)

DCK3-25/2 240V(2PC)

DCK3-30/2 24V(2PC)

DCK3-30/2 120V(2PC)

DCK3-30/2 240V(2PC)

DCK3-40/2 24V(2PC)

DCK3-40/2 120V(2PC)

DCK3-40/2 240V(2PC)

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

DEFINITE PURPOSE AC CONTACTOR SERIES

M-16 www.dixsen.com www.dixsen.com M-17

M M

Page 17: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

ApprovalType Case

Qty.

(Pcs)

Item

code

TERMINALS SELECTION

There are three sorts of terminals for 1P and 2P of DCK3, please see right photos.

1. Binder Head Screw (code W): pressing connects

2.Screw with square washer( code Y): pressing connects

3.Box Lug (code N): quick connects

Necessary information required for order : Please indicate the terminals type on ordering.

BinderHead Screw (W)

Screw withsquare washer (Y)

Box Lug (N)

Ref.

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

20

20

20

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

24

120

240

cULus

cULus

-

-

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

40

40

40

40

40

40

40

40

40

40

40

40

43209024

43209120

43209240

43259024

43259120

43259240

43309024

43309120

43309240

43409024

43409120

43409240

DCK3-20/2 24V(2PCS)

DCK3-20/2 120V(2PCD)

DCK3-20/2 240V(2PCS)

DCK3-25/2 24V(2PCS)

DCK3-25/2 120V(2PCS)

DCK3-25/2 240V(2PCS)

DCK3-30/2 24V(2PCS)

DCK3-30/2 120V(2PCS)

DCK3-30/2 240V(2PCS)

DCK3-40/2 24V(2PCS)

DCK3-40/2 120V(2PCS)

DCK3-40/2 240V(2PCS)

DEFINITE PURPOSE AC CONTACTOR SERIES

GENERAL

DCK3 Series definite purpose AC contactor are designed for use in refrigeration, air conditionin g, and electric heating syst-

ems . Power connections can be made with either screw terminals with quick onnects or l ug terminals with quick connects. Standard

According:

GB14048.4, UL508, IEC60947-4.

DCK3 Series (1P & 2P) Specification

DCK3-20/1 24V

DCK3-20/1 120V

DCK3-20/1 240V

DCK3-25/1 24V

DCK3-25/1 120V

DCK3-25/1 240V

DCK3-30/1 24V

DCK3-30/1 120V

DCK3-30/1 240V

1P

1P

1P

1P

1P

1P

1P

1P

1P

20

20

20

25

25

25

30

30

30

24

120

240

24

120

240

24

120

240

-

-

-

-

-

-

cULus

cULus

cULus

40

40

40

40

40

40

40

40

40

DCK3-20/2 24V(2P)

DCK3-20/2 120V(2P)

DCK3-20/2 240V(2P)

DCK3-25/2 24V(2P)

DCK3-25/2 120V(2P)

DCK3-25/2 240V(2P)

DCK3-30/2 24V(2P)

DCK3-30/2 120V(2P)

DCK3-30/2 240V(2P)

DCK3-40/2 24V(2P)

DCK3-40/2 120V(2P)

DCK3-40/2 240V(2P)

20

20

20

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

24

120

240

20

20

20

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

24

120

240

cULus

cULus

-

-

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

40

40

40

40

40

40

40

40

40

40

40

40

No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

ApprovalType Case

Qty.(Pcs)

Item

code

cULus

cULus

-

-

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

40

40

40

40

40

40

40

40

40

40

40

40

43201024

43201120

43201240

43251024

43251120

43251240

43301024

43301120

43301240

43202024

43202120

43202240

43252024

43252120

43252240

43302024

43302120

43302240

43402024

43402120

43402240

43206024

43206120

43206240

43256024

43256120

43256240

43306024

43306120

43306240

43406024

43406120

43406240

Ref.

DCK3-20/2 24V(2PC)

DCK3-20/2 120V(2PC)

DCK3-20/2 240V(2PC)

DCK3-25/2 24V(2PC)

DCK3-25/2 120V(2PC)

DCK3-25/2 240V(2PC)

DCK3-30/2 24V(2PC)

DCK3-30/2 120V(2PC)

DCK3-30/2 240V(2PC)

DCK3-40/2 24V(2PC)

DCK3-40/2 120V(2PC)

DCK3-40/2 240V(2PC)

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

2P

DEFINITE PURPOSE AC CONTACTOR SERIES

M-16 www.dixsen.com www.dixsen.com M-17

M M

Page 18: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

3P

(W/Y/N available)

DCK3-25/3 24V (3PS)

DCK3-25/3 120V (3PS)

DCK3-25/3 240V (3PS)

DCK3-30/3 24V (3PS)

DCK3-30/3 120V (3PS)

DCK3-30/3 240V (3PS)

DCK3-40/3 24V (3PS)

DCK3-40/3 120V (3PS)

DCK3-40/3 240V (3PS)

3P

3P

3P

3P

3P

3P

3P

3P

3P

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

32

32

32

32

32

32

32

32

323PS

(W/Y/N available)

BinderHead Screw (W)

TERMINALS SELECTION

Necessary information required for order : Please indicate the terminals type on ordering.

Note: Difference of PB, PA, PS model, please contact our sales team.

There are three sorts of terminals for 3P of DCK3, please see right photos.

1. Binder Head Screw (code W): pressing connects

2.Screw with square washer( code Y): pressing connects

3.Box Lug (code N): quick connects

3P

3P

3P

3P

3P

3P

3P

3P

3P

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

32

32

32

32

32

32

32

32

32

DEFINITE PURPOSE AC CONTACTOR DCK3 SERIES

43255024

43255120

43255240

43305024

43305120

43305240

43405024

43405120

43405240

43257024

43257120

43257240

43307024

43307120

43307240

43407024

43407120

43407240

Ref.

DCK3-25/3 24V (3P)

DCK3-25/3 120V (3P)

DCK3-25/3 240V (3P)

DCK3-30/3 24V (3P)

DCK3-30/3 120V (3P)

DCK3-30/3 240V (3P)

DCK3-40/3 24V (3P)

DCK3-40/3 120V (3P)

DCK3-40/3 240V (3P)

Screw withsquare washer (Y)

Box Lug (N)

No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

ApprovalType Case

Qty.

(Pcs)

Item

code

APPLICATION

1. Air Conditioning

2. Heating

3. Ventilating

4. Refrigeration

5. Food and Beverage Industries

6. Hoist and Cranes

7. Elevators

8. Lighting

9. Pool and Spa

10. Welding

11. Pump and Compressor

12. Conveyors

3PB

(W/Y/N available)

DEFINITE PURPOSE AC CONTACTOR DCK3 SERIES

3PA

(W/Y/N available)

DCK3-25/3 24V (3PB)

DCK3-25/3 120V (3PB)

DCK3-25/3 240V (3PB)

DCK3-30/3 24V (3PB)

DCK3-30/3 120V (3PB)

DCK3-30/3 240V (3PB)

DCK3-40/3 24V (3PB)

DCK3-40/3 120V (3PB)

DCK3-40/3 240V (3PB)

3P

3P

3P

3P

3P

3P

3P

3P

3P

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

32

32

32

32

32

32

32

32

32

43258024

43258120

43258240

43308024

43308120

43308240

43408024

43408120

43408240

Ref.

SPECIFICATION

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

25

25

25

30

30

30

40

40

40

50

50

50

60

60

60

75

75

75

24

120

240

24

120

240

24

120

240

24

120

240

24

120

240

24

120

240

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

CULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

32

32

32

32

32

32

32

32

32

32

32

32

32

32

32

32

32

32

43253024

43253120

43253240

43303024

43303120

43303240

43403024

43403120

43403240

43503024

43503120

43503240

43603024

43603120

43603240

43753024

43753120

43753240

DCK3-25/3 24V (3PA)

DCK3-25/3 120V (3PA)

DCK3-25/3 240V (3PA)

DCK3-30/3 24V (3PA)

DCK3-30/3 120V (3PA)

DCK3-30/3 240V (3PA)

DCK3-40/3 24V (3PA)

DCK3-40/3 120V (3PA)

DCK3-40/3 240V (3PA)

DCK3-50/3 24V (3PA)

DCK3-50/3 120V (3PA)

DCK3-50/3 240V (3PA)

DCK3-60/3 24V (3PA)

DCK3-60/3 120V (3PA)

DCK3-60/3 240V (3PA)

DCK3-75/3 24V (3PA)

DCK3-75/3 120V (3PA)

DCK3-75/3 240V (3PA)

Type No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

Approval Item

code

Case

Qty.

(Pcs)

M-18 www.dixsen.com www.dixsen.com M-19

M M

Page 19: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

3P

(W/Y/N available)

DCK3-25/3 24V (3PS)

DCK3-25/3 120V (3PS)

DCK3-25/3 240V (3PS)

DCK3-30/3 24V (3PS)

DCK3-30/3 120V (3PS)

DCK3-30/3 240V (3PS)

DCK3-40/3 24V (3PS)

DCK3-40/3 120V (3PS)

DCK3-40/3 240V (3PS)

3P

3P

3P

3P

3P

3P

3P

3P

3P

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

32

32

32

32

32

32

32

32

323PS

(W/Y/N available)

BinderHead Screw (W)

TERMINALS SELECTION

Necessary information required for order : Please indicate the terminals type on ordering.

Note: Difference of PB, PA, PS model, please contact our sales team.

There are three sorts of terminals for 3P of DCK3, please see right photos.

1. Binder Head Screw (code W): pressing connects

2.Screw with square washer( code Y): pressing connects

3.Box Lug (code N): quick connects

3P

3P

3P

3P

3P

3P

3P

3P

3P

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

32

32

32

32

32

32

32

32

32

DEFINITE PURPOSE AC CONTACTOR DCK3 SERIES

43255024

43255120

43255240

43305024

43305120

43305240

43405024

43405120

43405240

43257024

43257120

43257240

43307024

43307120

43307240

43407024

43407120

43407240

Ref.

DCK3-25/3 24V (3P)

DCK3-25/3 120V (3P)

DCK3-25/3 240V (3P)

DCK3-30/3 24V (3P)

DCK3-30/3 120V (3P)

DCK3-30/3 240V (3P)

DCK3-40/3 24V (3P)

DCK3-40/3 120V (3P)

DCK3-40/3 240V (3P)

Screw withsquare washer (Y)

Box Lug (N)

No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

ApprovalType Case

Qty.

(Pcs)

Item

code

APPLICATION

1. Air Conditioning

2. Heating

3. Ventilating

4. Refrigeration

5. Food and Beverage Industries

6. Hoist and Cranes

7. Elevators

8. Lighting

9. Pool and Spa

10. Welding

11. Pump and Compressor

12. Conveyors

3PB

(W/Y/N available)

DEFINITE PURPOSE AC CONTACTOR DCK3 SERIES

3PA

(W/Y/N available)

DCK3-25/3 24V (3PB)

DCK3-25/3 120V (3PB)

DCK3-25/3 240V (3PB)

DCK3-30/3 24V (3PB)

DCK3-30/3 120V (3PB)

DCK3-30/3 240V (3PB)

DCK3-40/3 24V (3PB)

DCK3-40/3 120V (3PB)

DCK3-40/3 240V (3PB)

3P

3P

3P

3P

3P

3P

3P

3P

3P

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

32

32

32

32

32

32

32

32

32

43258024

43258120

43258240

43308024

43308120

43308240

43408024

43408120

43408240

Ref.

SPECIFICATION

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

3P

25

25

25

30

30

30

40

40

40

50

50

50

60

60

60

75

75

75

24

120

240

24

120

240

24

120

240

24

120

240

24

120

240

24

120

240

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

CULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

cULus

32

32

32

32

32

32

32

32

32

32

32

32

32

32

32

32

32

32

43253024

43253120

43253240

43303024

43303120

43303240

43403024

43403120

43403240

43503024

43503120

43503240

43603024

43603120

43603240

43753024

43753120

43753240

DCK3-25/3 24V (3PA)

DCK3-25/3 120V (3PA)

DCK3-25/3 240V (3PA)

DCK3-30/3 24V (3PA)

DCK3-30/3 120V (3PA)

DCK3-30/3 240V (3PA)

DCK3-40/3 24V (3PA)

DCK3-40/3 120V (3PA)

DCK3-40/3 240V (3PA)

DCK3-50/3 24V (3PA)

DCK3-50/3 120V (3PA)

DCK3-50/3 240V (3PA)

DCK3-60/3 24V (3PA)

DCK3-60/3 120V (3PA)

DCK3-60/3 240V (3PA)

DCK3-75/3 24V (3PA)

DCK3-75/3 120V (3PA)

DCK3-75/3 240V (3PA)

Type No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

Approval Item

code

Case

Qty.

(Pcs)

M-18 www.dixsen.com www.dixsen.com M-19

M M

Page 20: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

OUTLINES AND DIMENSION IN MM. (FOR ESTIMATING ONLY)

70.5

61

82.5

60

47

.8

38.5

64

95

75.5

64

22

74.9

18

.1 51

55

41.5

A

49

.2

5.5

60.6

A

11.8

5

11

56

.4

3.5

6

R3

R57.5

82.5

44

.5

5

7.5

11

5

A

65

86

88

.5

95

80

A

L1

L2

L3

T1

T2

T3

Dix

se

nA

.C.C

nta

cto

rD

CK

3-4

0 R

ate

d c

urr

en

t 4

0A

Co

il Vo

lt 22

0V

50

/60

Hz

IEC

94

7-4

-1

82.5

A

44

.5

115

5

7.565

60

88

.5

A

95

80

1P

2P

3PS

4PS

38.5

64

DEFINITE PURPOSE AC CONTACTOR DCK3 SERIES

GENERAL

DCK3 SERIES (4P) SPECIFICATION

4PS

(W/Y/N available)

Reversing Contactor

4P

4P

4P

4P

4P

4P

4P

4P

4P

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

4P

4P

4P

4P

4P

4P

4P

4P

4P

25

25

25

30

30

30

40

40

40

2DCK3-25/4 24V

2DCK3-25/4 120V

2DCK3-25/4 240V

2DCK3-30/4 24V

2DCK3-30/4 120V

2DCK3-30/4 240V

2DCK3-40/4 24W

2DCK3-40/4 120V

2DCK3-40/4 240V

24

120

240

24

120

240

24

120

240

Necessary information required for order : Please ind icate the terminals type on ordering, additional,

2DCK3 3PS Reversing type available.

Reversing Hoist contactors are designed for the control of motors in hoists, overhead doors, small elevators, commercial laundry equipment,

and other related products which use revering motors. They are rated to perform in the short periods of jogging experienced in hoist service.

They are suitable for other non cycling duty application requiring reliable low cost switching. Standard required: GB14048.4, UL508, IEC60947-4.

There are three sorts of terminals for 4P of DCK3, please see

right photos.

1. Binder Head Screw (code W): pressing connects

2.Screw with square washer( code Y): pressing connects

3.Box Lug Boxlug (code N): quick connects

32

32

32

32

32

32

32

32

32

16

16

16

16

16

16

16

16

16

BinderHead Screw (W)

Box Lug (N) ReversingkitOnly one sort of Reversing Kit for the Reversing Contactor,

Please see right photo.

DEFINITE PURPOSE AC CONTACTOR DCK3 SERIES

43250024

43250120

43250240

43300024

43300120

43300240

43400024

43400120

43400240

43254024

43254120

43254240

43304024

43304120

43304240

43404024

43404120

43404240

Ref.

Ref.

DCK3-25/4 24V (4PS)

DCK3-25/4 120V (4PS)

DCK3-25/4 240V (4PS)

DCK3-30/4 24V (4PS)

DCK3-30/4 120V (4PS)

DCK3-30/4 240V (4PS)

DCK3-40/4 24W (4PS)

DCK3-40/4 120V (4PS)

DCK3-40/4 240V (4PS)

REVERSING CONTACTOR(FOR 4PS) SPECIFICATION

TERMINALS SELECTION

Screw withsquare washer (Y)

Type No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

Item

code

Case

Qty.

(Pcs)

Type No. of

Poles

Coil Voltage

50/60Hz(V)

Item

code

Case

Qty.

(Pcs)

Rated

Current(A)

M-20 www.dixsen.com www.dixsen.com M-21

M M

Page 21: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

OUTLINES AND DIMENSION IN MM. (FOR ESTIMATING ONLY)

70.5

61

82.5

60

47

.8

38.5

64

95

75.5

64

22

74.9

18

.1 51

55

41.5

A

49

.2

5.5

60.6

A

11.8

5

11

56

.4

3.5

6

R3

R57.5

82.5

44

.5

5

7.5

11

5

A

65

86

88

.5

95

80

A

L1

L2

L3

T1

T2

T3

Dix

se

nA

.C.C

nta

cto

rD

CK

3-4

0 R

ate

d c

urr

en

t 4

0A

Co

il Vo

lt 22

0V

50

/60

Hz

IEC

94

7-4

-1

82.5

A

44

.5

115

5

7.565

60

88

.5

A

95

80

1P

2P

3PS

4PS

38.5

64

DEFINITE PURPOSE AC CONTACTOR DCK3 SERIES

GENERAL

DCK3 SERIES (4P) SPECIFICATION

4PS

(W/Y/N available)

Reversing Contactor

4P

4P

4P

4P

4P

4P

4P

4P

4P

25

25

25

30

30

30

40

40

40

24

120

240

24

120

240

24

120

240

4P

4P

4P

4P

4P

4P

4P

4P

4P

25

25

25

30

30

30

40

40

40

2DCK3-25/4 24V

2DCK3-25/4 120V

2DCK3-25/4 240V

2DCK3-30/4 24V

2DCK3-30/4 120V

2DCK3-30/4 240V

2DCK3-40/4 24W

2DCK3-40/4 120V

2DCK3-40/4 240V

24

120

240

24

120

240

24

120

240

Necessary information required for order : Please ind icate the terminals type on ordering, additional,

2DCK3 3PS Reversing type available.

Reversing Hoist contactors are designed for the control of motors in hoists, overhead doors, small elevators, commercial laundry equipment,

and other related products which use revering motors. They are rated to perform in the short periods of jogging experienced in hoist service.

They are suitable for other non cycling duty application requiring reliable low cost switching. Standard required: GB14048.4, UL508, IEC60947-4.

There are three sorts of terminals for 4P of DCK3, please see

right photos.

1. Binder Head Screw (code W): pressing connects

2.Screw with square washer( code Y): pressing connects

3.Box Lug Boxlug (code N): quick connects

32

32

32

32

32

32

32

32

32

16

16

16

16

16

16

16

16

16

BinderHead Screw (W)

Box Lug (N) ReversingkitOnly one sort of Reversing Kit for the Reversing Contactor,

Please see right photo.

DEFINITE PURPOSE AC CONTACTOR DCK3 SERIES

43250024

43250120

43250240

43300024

43300120

43300240

43400024

43400120

43400240

43254024

43254120

43254240

43304024

43304120

43304240

43404024

43404120

43404240

Ref.

Ref.

DCK3-25/4 24V (4PS)

DCK3-25/4 120V (4PS)

DCK3-25/4 240V (4PS)

DCK3-30/4 24V (4PS)

DCK3-30/4 120V (4PS)

DCK3-30/4 240V (4PS)

DCK3-40/4 24W (4PS)

DCK3-40/4 120V (4PS)

DCK3-40/4 240V (4PS)

REVERSING CONTACTOR(FOR 4PS) SPECIFICATION

TERMINALS SELECTION

Screw withsquare washer (Y)

Type No. of

Poles

Rated

Current(A)

Coil Voltage

50/60Hz(V)

Item

code

Case

Qty.

(Pcs)

Type No. of

Poles

Coil Voltage

50/60Hz(V)

Item

code

Case

Qty.

(Pcs)

Rated

Current(A)

M-20 www.dixsen.com www.dixsen.com M-21

M M

Page 22: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

18001

18002

18003

18005

18006

18007

30

30

30

18

18

18

24

120

240

24

120

240

Rated

Current(A)

Order

No.

Ref. Type Case

Qty.(Pcs)

Coil Voltage

(VAC)

cULus

-

-

-

-

-

DPST

DPST

DPST

DPST

DPST

DPST

Switch Approval

COLE

Schematic

80

80

80

80

80

80

Power RELAY

CM-20/1

CM-20/2

CM-20/3

CM-20/4

CM-25/1

CM-25/1

CM-25/1

CM-25/1

CM-32/1

CM-32/2

CM-32/3

CM-32/4

CM-40/1

CM-40/2

CM-40/3

CM-40/4

CM-63/1

CM-63/2

CM-63/3

CM-63/4

1P

2P

3P

4P

1P

2P

3P

4P

1P

2P

3P

4P

1P

2P

3P

4P

1P

2P

3P

4P

No.

of Poles

20

20

20

20

25

25

25

25

32

32

32

32

40

40

40

40

63

63

63

63

Rated Current(A)

@230VAC

20

20

20

20

25

25

25

25

32

32

32

32

40

40

40

40

63

63

63

63

Rated Thermal

Current(A)

Order

No.

Ref.

3130201

3130202

3130203

3130204

3132501

3132502

3132503

3132504

3133201

3133202

3133203

3133204

3134001

3134002

3134003

3134004

3136301

3136302

3136303

3136304

DIN RAIL CONTACTOR

APPLICATION

CM mini AC contactor mainly applies to circuit of AC 50Hz (or 60Hz), rated working voltage up to 400V,rated work ing c urrent up to

63A to cont rol household electric appliances and low inductive reactance load and mi cro i nduct ive r eactance load of similar usage,

can also boused to contro l ho-usehold motor load of which the controlling power needs to be relatively decreased.

This product applies to places such as household,hotels,apartments,etc to realize the automa-tion of large-scale produced household

electric appliances,its main performance indices comply whi t standards of IEC1095 etc.

Type Case

Qty.(Pcs)

120

120

60

60

120

120

60

60

60

60

40

40

60

60

40

40

60

60

40

40

50018001

50018002

50018003

50018005

50018006

50018007

M-22 www.dixsen.com www.dixsen.com M-23

M M

Page 23: AC CONTACTOR - dixsen.com · AC CONTACTOR Contactors provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instru-ments

18001

18002

18003

18005

18006

18007

30

30

30

18

18

18

24

120

240

24

120

240

Rated

Current(A)

Order

No.

Ref. Type Case

Qty.(Pcs)

Coil Voltage

(VAC)

cULus

-

-

-

-

-

DPST

DPST

DPST

DPST

DPST

DPST

Switch Approval

COLE

Schematic

80

80

80

80

80

80

Power RELAY

CM-20/1

CM-20/2

CM-20/3

CM-20/4

CM-25/1

CM-25/1

CM-25/1

CM-25/1

CM-32/1

CM-32/2

CM-32/3

CM-32/4

CM-40/1

CM-40/2

CM-40/3

CM-40/4

CM-63/1

CM-63/2

CM-63/3

CM-63/4

1P

2P

3P

4P

1P

2P

3P

4P

1P

2P

3P

4P

1P

2P

3P

4P

1P

2P

3P

4P

No.

of Poles

20

20

20

20

25

25

25

25

32

32

32

32

40

40

40

40

63

63

63

63

Rated Current(A)

@230VAC

20

20

20

20

25

25

25

25

32

32

32

32

40

40

40

40

63

63

63

63

Rated Thermal

Current(A)

Order

No.

Ref.

3130201

3130202

3130203

3130204

3132501

3132502

3132503

3132504

3133201

3133202

3133203

3133204

3134001

3134002

3134003

3134004

3136301

3136302

3136303

3136304

DIN RAIL CONTACTOR

APPLICATION

CM mini AC contactor mainly applies to circuit of AC 50Hz (or 60Hz), rated working voltage up to 400V,rated work ing c urrent up to

63A to cont rol household electric appliances and low inductive reactance load and mi cro i nduct ive r eactance load of similar usage,

can also boused to contro l ho-usehold motor load of which the controlling power needs to be relatively decreased.

This product applies to places such as household,hotels,apartments,etc to realize the automa-tion of large-scale produced household

electric appliances,its main performance indices comply whi t standards of IEC1095 etc.

Type Case

Qty.(Pcs)

120

120

60

60

120

120

60

60

60

60

40

40

60

60

40

40

60

60

40

40

50018001

50018002

50018003

50018005

50018006

50018007

M-22 www.dixsen.com www.dixsen.com M-23

M M