AB* SERIES AIR HANDLER UNITS INSTALLATON GUIDE GENERAL The AB* Series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the ceiling. AB* Series models are for electric heat, DX cooling, and for heat pump applications. The unit can be configured for return air flow through the integral access panel or at the end of the unit. Installation tabs are built into the cabinet to facilitate mounting the unit. Optional panels are available that allow a wide range of installation options. Electric resistance heaters are available along with optional air conditioning and heat pump indoor coils. Full service of all components is easily accomplished through the access panels. WARNING: Do not operate this unit unless all service panels/access doors are in place. If unit is located in the same area as the water heater or boiler, then the return air must be ducted to the unit. Seal all sevice entrances to the unit to prevent combustible byproducts from the water heater or boiler entering the air stream. Installation of this unit shall be made in accordance with the National Electric Code, NFPA No. 90A and 90B, and any other local codes or utilities requirements. WARNING: Due to possible damage to equipment or personal injury, installation, service, and maintenance should only be performed aby a trained, qualified person. Consumer service is recommended only for filter replacement. WARNING: HAZARDOUS VOLTAGE - Ensure all power is disconnected before installing or servicing this unit. More than one disconnect device may be required to de-energize the equipment. Hazardous voltage can cause severe personal injury. Make certain all panels are in place before operating this unit. 9.2020 UNPACKING Carefully unpack the unit and inspect the contents for damage. If any damage is found at the time of delivery proper notification and claims should be made with the carrier who delivered the unit. Check the unit rating plate to assure model number and voltage, plus any kits agree with what you ordered. The manufacturer should be notified within 5 days of any discrepancy or parts shortage LOCATION The blower coil unit should be centrally located and may be installed above a suspended ceiling with integral supply/return, or recessed in the ceiling. The cabinet of the unit serves as a supply plenum for attaching duct work. This unit is approved for ‘0”’ clearandce from any side, front, rear, or duct work. The unit must be installed in a level position to ensure proper condensation drainage. Make sure the unit is level in both directions within 1/8”.

Upload: others

Post on 06-Apr-2022

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

AB* SERIESAIR HANDLER UNITS INSTALLATON GUIDE

GENERAL

The AB* Series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the ceiling. AB* Series models are for electric heat, DX cooling, and for heat pump applications. The unit can be configured for return air flow through the integral access panel or at the end of the unit. Installation tabs are built into the cabinet to facilitate mounting the unit. Optional panels are available that allow a wide range of installation options. Electric resistance heaters are available along with optional air conditioning and heat pump indoor coils. Full service of all components is easily accomplished through the access panels.

WARNING: Do not operate this unit unless all service panels/access doors are in place. If unit is located in the same area as the water heater or boiler, then the return air must be ducted to the unit. Seal all sevice entrances to the unit to prevent combustible byproducts from the water heater or boiler entering the air stream.

Installation of this unit shall be made in accordance with the National Electric Code, NFPA No. 90A and 90B, and any other local codes or utilities requirements.

WARNING: Due to possible damage to equipment or personal injury, installation, service, and maintenance should only be performed aby a trained, qualified person. Consumer service is recommended only for filter replacement.

WARNING: HAZARDOUS VOLTAGE - Ensure all power is disconnected before installing or servicing this unit. More than one disconnect device may be required to de-energize the equipment. Hazardous voltage can cause severe personal injury. Make certain all panels are in place before operating this unit.

9.2020

UNPACKING

Carefully unpack the unit and inspect the contents for damage. If any damage is found at the time of delivery proper notification and claims should be made with the carrier who delivered the unit.

Check the unit rating plate to assure model number and voltage, plus any kits agree with what you ordered. The manufacturer should be notified within 5 days of any discrepancy or parts shortage

LOCATION

The blower coil unit should be centrally located and may be installed above a suspended ceiling with integral supply/return, or recessed in the ceiling. The cabinet of the unit serves as a supply plenum for attaching duct work. This unit is approved for ‘0”’ clearandce from any side, front, rear, or duct work. The unit must be installed in a level position to ensure proper condensation drainage. Make sure the unit is level in both directions within 1/8”.

Page 2: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

INSTALLATON GUIDE

When the unit is installed in a suspended ceiling, it must be independently suspended from structural members. The AB* is designed to fit within the grid of the suspended ceiling. All servicing is done from the bottom of the unit through the access panel.

The unit incorporates installation tabs that mount to the framing and provide a 1/2” flange to trim to the finished edge of a sheet rock ceiling. The face panel mounts to the cabinet and trims the installation.

All service entrances and exits on the cabinet are recessed to allow for 2” x 4” framing of the opening. Any modifications to existing framing should be accomplished by the general contractor to ensure structural strength is maintained in the structure.

The structural opening in the framing should be 48” long and 24” wide. The unit should be positioned where the bottome edge of the cabinet is 1/2” below the framing member.

DUCT WORK

The duct work should be installed in accordance with the NFPA No. 90A “Installation of Air Conditioning and Ventilating Systems” and NFPA No. 90B “Residential Type Warm Air Heating and Air Conditioning Installation”.

The duct work should be insulated in accordance with the applicabale requirements for the particular type installation as required by HUD, FHA, VA, the Applicable Building Code, Local Utility or other governing body.

CONDENSATE DRAINS

The AB* air conditioning or heat pump coil is supplied with 3/4” primary and auxiliary condensate drains. Both drains must be trapped outside the unit and piped in accordance with applicable building codes. Do not reduce the drain line size less than connection size on the drain pan. Condensate should be piped to an open drain or to the outside. All drains must pitch downward away from the unit a minimum of 1/8” per foot of line to ensure proper drainage.

REFRIGERANT PIPING

Refrigerant piping external to the unit shall be sized in accordance with the instructions of the manufacturer of the outdoor equipment.

When units are recess mounted, make certain that the piping connections are pressure tested prior to the wall

being closed.

METERING DEVICE

Optional air conditioning or heat pump coils are shipped with a check-flow piston installed which is designed for air conditioning or heat pump operation unless the unit is specifically ordered with the valve installed (this is indicated with ‘+V or +VP’ in the model number of the unit. If your application requires the addition of a thermal expansion valve or check expansion valve then it is necessary to remove the piston from the distributor assembly and install the proper metering device. Be sure to follow the instructions in the kit to ensure proper installation.

WIRING

Consult all schematic and pictorial wiring diagrams of this unit and the outdoor equipment to determine compatibility of the wiring connections and to determine specific requirements.

All field wiring to the blower coil should be installed in accordance with the latest edition of the National Electric Code NFPA No. 70 and any local codes.

Check rating plate on unit for rated volts, minimum circuit ampacity and maximum over current protection. Supply circuit power wiring must be 75°C (167°F) minimum copper conductors only. Copper supply wires shall be sized to the National Electric Code or local code requirements, whichever is larger.

The unit is shipped wired for 115/120V or 230/240V AC, 60Hz, 1 Phase Operation. If the unit is to be operated at 208VAC/60Hz., then follow the instructions on the indoor unit wiring diagram to change the low voltage transformer to 208VAC Operation.

Be sure the unit is properly grounded.

Class 2 low voltage control wiring should not be run in conduit with power wiring and must be separated from power wiring, unless class 1 wire of proper voltage rating is used. Low voltage control wiring should be 18 AWG, color coded (105°C minimum). For lengths longer than 100ft., 16 AWG. wire should be used.

Make certain that separation of control wiring and power wiring has been maintained.

Page 3: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

INSTALLATON GUIDE

THERMOSTAT

Select a thermostat that is commonly referred to as a single stage cooling with electric sub base. This stat will energize the fan on a demand for heat or cool.

Installl the thermostat on an inside wall away from drafts, lights or other heat sources in a location that has good air ciculation from the other rooms being controlled by the thermostat. The thermostat should be mounted 4’ to 5’ above the floor.

AIR FILTER

An air filter must be installed prior to the air entering the evaporator coil to protect the coil, blower, and other internal parts from excessive dirt and dust. If the unit installed with the face panel to seve as the return air grille, trhen the integral return air filter may be used. If a remote return air is required, then a solid face panel and filter grille is required. Ductwork should be installed to facilitate the return air entering the back of the return air section of the unit. The door must be securely fastened in place to ensure proper filtration of the return air. Change the filter every 30 days or as soon as dust or dirt appears on the filter.

BLOWER

The unit is shipped with a multi-speed motor with a direct drive blower wheel which can obtain various air flows. As an option a ECM motor is also available. This motor provides variable speeds at a constant torque. The unit is shipped with the blower connected for high speed cooling and low speed heat. Before making any changes, disconnect all power to the unit, be sure to check the particular motor in the unit to determine the number of speed available, select the proper speed lead for cooling and connect it to determine the number of speeds available, select the proper speed lead for cooling and connect it to lthe normal closed terminal on the fan relay. Any speed leads that are not used must have the terminals insulated and protected. Be sure to check the air flow and the temperature drop/rise across the unit to ensure that you have sufficient air flow.

SEQUENCE OF OPERATION

Cooling (cooling only or heat pump with reversing valve energized in heat mode): When the T-Stat calls for cooling, the circuit between R and G is complete, and the blower relay is energized. The N.O. contacts will close, which allows the indoor blower to operate.

The circuit between R and Y is completed causing the contactor on the outdoor equipment to close, and start the compressor and the outdoor fan motor.

Cooling (heat pump with reversing valve energized in cooling mode): When the thermostat calls for cooling, the circuit between R and G and R and O is complete. Circuit R and O energizes the reversing vavle to the cooling position. Circuit R and G energizes the blower relay. The N.O. contacts will close after a time delay then the indoor blower will operate. The circuit between R and Y is complete. Which causes the contactor on the outdoor equipment to close, and the start the compressor and the outdoor fan motor.

Heating (electric heat only): When the thermostat calls for heat, the circuit between R and W is completed. The heat sequencer is energized. A time delay will occur, which allows the heating element(s) and the indoor blower motor to come on.

Heating (heat pump reversing valve energized in the heat mode): When the thermostat calls for heat, the cicuits between R and B, R and Y and R and G are completed. Circuit R and B energize the reversing valve switching it to the heat position. Circuit R and Y energized the outdoor unit contactor starting the compressor and outdoor fan. Circuit R and G energizes the blower relay starting the blower motor.

If the indoor room temperature should continue to fall, circuit R and W2 is by the second-stage heat bulb on the thermostat. Circuit R-W2 energizes the heat sequencer. The completed ciruit will energize the supplemental electric heat.

Blower Time Delay: This unit is equipped with timed on and a timed off relay. This relay delays the start and delay the stoppig of the indoor fan motor to maximize the efficiency of the unit.

Defrost: When the unit starts the defrost cycle supplemental heat can be jprovided by connecting B on the blower coil to the defrost relay on the outdoor heat pump. This will complete the ciruit between R and B (in the blower coil) through a set of contacts in the defrost relay in the outdoor unit. This circuit when it is connedcted, will help prevent cold air from being discharged from the indoor unit during the defrost.

Page 4: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

START UP

Once all connections are complete the unit should be started up, and a check out of the completed system should be performed. Before performing any system test, make sure that all grilles, registers, and dampers are open and set to the correct position. Also make certain that the air filter is installed in the return air prior to running the air handler.

A performance test should be conducted in the accordance with the outdoor equipment manufacturer’s instructions. Airflow tests should be conducted in the heating and cooling modes to ensure satisfactory operation.

MAINTENANCE

The system air filter(s) should be inspected, cleaned or replaced at least monthly. If the filter is mounted internal to unit, make sure that electrical power is disconnected before removing the access panels. Make certain the access panels are replaced and secured properly before placing the unit back in operation. This product is designed for dependable service, however periodic maintenance should be scheduled to be conducted by trained professional service personnel. This service should be conducted at least annually, and should include testing and inspection of electrical and refrigerant components. The heat transfer surface should be cleaned. The blower motor is permanently lubricated for normal operating conditions.

NOTE:

The condenate drain pan shown in Figure 1, has an adjustment strap to ensure proper condensate removal. The strap is identified by the arrow in the figures. If it is found to be necessary, the strap may be easily loosended and refastened to change the pitch in the drain pan toward the drain outlets. The drain pan pitch should not exceed 1/2”. For proper drain line connections, follow instructions from “CONDENSATE DRAIN”.

INSTALLATON GUIDE

WARNINGS

Do not store or use any corrosives or combustibles in the vicinity of this unit. All panels must be in place and properly secured before operating this equipment.

All electrical power servicing this unit must be disconnected prior to removal of any panels. Service of this unit must be accomplished by qualified trained professional personnel only.

Figure 1: Drain Pan Adjustment Strap

THIS UNIT IS MANUFACTURED IN THE USA BY:

Page 5: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

WIRING DIAGRAM

24 6

5 13

FAN

REL

AY

24 6

5 13

Ora

nge

L1 L2

CIR

CU

IT N

O.1

230V

olts

/60H

z/1P

h GN

D

WG

RY

THER

MO

STAT

IND

OO

RM

OTO

R

Purple or White

Blac

kBl

ueR

ed

Red

Orange

TRANSFORMER

24V

USE

CO

PPER

CO

NN

ECTO

RS

ON

LY.

Use

Con

duct

ors

Suita

ble

for 1

67 D

eg F

.

EQU

IPM

ENT

GR

OU

ND

USE

CO

PPER

OR

ALU

MIN

UM

WIR

E.

DIS

CO

NN

ECT

POW

ER B

EFO

RE

INST

ALLA

TIO

N O

R S

ERVI

CIN

G.

MU

LTIP

LE P

OW

ER S

OU

RC

ESM

AY B

E PR

ESEN

T.FA

ILU

RE

TO D

O S

O M

AYC

AUSE

PR

OPE

RTY

DAM

AGE,

PER

SON

AL IN

JUR

Y, O

R D

EATH

.

230v

Com

Sing

le S

peed

Fan

Con

trol

Con

nect

Onl

y O

ne F

an L

ead

Not

all

mod

els

have

3 s

peed

s

Blac

k - H

igh

Spee

dBl

ue -

Med

ium

Spe

edR

ed -

Low

Spe

ed

AW19

10-5

5374

-C1

TER

MIN

AL B

LOC

K/D

ISC

ON

NEC

T

Alls

tyle

Coi

l Com

pany

, LP

7037

Brit

tmoo

re R

d, H

oust

on, T

exas

770

41

Black

Brow

nBr

own/

Whi

te

Blac

k

Gre

en

Yellow

Orange

BlueBl

ue

Blue 208v

See

OU

TDO

OR

UN

IT

Purp

le

Not

e 1

Red

230

Volt

Air H

andl

er w

ith N

o H

eat

24V

CLA

SS 2

Wiri

ng

AW19

10-5

5374

-C1

Purp

le

Yello

w

Green

Gre

en

C

FAC

TOR

Y W

IRIN

G

NO

TE 1

) Wiri

ng c

hang

e is

requ

ired

to c

onve

rt tra

nsfo

rmer

to 2

08 V

olts

.D

isco

nnec

t pow

er.

Dis

conn

ect o

rang

e hi

gh v

olta

ge le

ad a

nd p

lace

on

term

inal

labe

led

as "2

08V"

for 2

08 V

olts

pow

er.

WIR

ING

TAB

LE

HIG

H V

OLT

AGE

WIR

ING

LOW

VO

LTAG

E W

IRIN

G

FIEL

D W

IRIN

G

CO

NSU

LT N

ATIO

NAL

CO

DE

FOR

PR

OPE

R W

IRE

SIZE

.

5-W

ire T

herm

osta

t Wiri

ng- C

term

inal

con

nect

s to

com

mon

4-W

ire T

herm

osta

t Wiri

ng- C

term

inal

not

nee

ded

**

**

Green

Page 6: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

WIRING DIAGRAM

USE COPPER CONNECTORS ONLY.Use Conductors Suitable for 167 Deg F.208-230VAC / 60Hz / 1Ph

EQUIPMENT GROUND USE COPPER ORALUMINUM WIRE.

Ora

nge

FACTORYWIRING TABLE

HIGH VOLTAGE WIRING

LOW VOLTAGE WIRING

Single Speed Fan ControlConnect Only One Fan LeadNot all models have 3 speeds

Black - High SpeedBlue - Medium SpeedRed - Low Speed

Air Handler with (AHF, AHK)

GND

L1

L2

M3

M4

M1

M2

Black

Red

Blac

kPu

rple

Brow

n

Whi

te

Blac

k

Blue

Blac

k

Blue

DISCONNECT POWER BEFOREINSTALLATION OR SERVICING.MULTIPLE POWER SOURCESMAY BE PRESENT.FAILURE TO DO SO MAYCAUSE PROPERTY DAMAGE,PERSONAL INJURY, OR DEATH.

Red

*AW1910-55361-B*

Blue

Black

BluePurple

Orange

Blue

Blue

BrownWhite

Whi

teBl

ue

ELEMENTHEATER

NOTE 1) Wiring change is required to convert transformer to208 Volts. Disconnect power. Disconnect orange highvoltage lead and place on terminal labeled as "208V" for 208Volts power.NOTE 2) Brown and White wires are used with Heat Kitsonly.

FIELD

CONSULT NATIONAL CODE FOR PROPER WIRE SIZE.

3, 5kW Heating Elements

AW1910-55361-B1

LIM

IT

FUSE

LIN

K

HEATERRELAY

2 4

651 3

FAN RELAY

2 4

651 3

G R C W

THERMOSTAT

INDOORMOTOR

Purple

Brow

n

White

TRNSF24V

230V

208VCom

SEE NOTE 2

RedBlue

Black

RedBlac

k

Brown/WhiteBrown

Gre

en

Purp

le

Red

24V CLASS 2 Wiring

Red

Blue

SEENOTE 1

Blue

Whi

te

Ora

nge

CIRCUIT NO. 1208-230/60/1

Y

OutdoorUnit

5-Wire Thermostat Wiring- C terminal connects to common4-Wire Thermostat Wiring- C terminal not needed**

**

Page 7: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

WIRING DIAGRAM

24V

WG

RC

THER

MO

STAT

Use

Con

duct

ors

Suita

ble

for 1

67 D

eg F

.

Gre

en

Red

Purp

le

TRAN

SFO

RM

ER

USE

CO

PPER

CO

NN

ECTO

RS

ON

LY.

EQU

IPM

ENT

GR

OU

ND

USE

CO

PPER

208-

230V

AC /

60H

z / 1

Ph

OR

ALU

MIN

UM

WIR

E.

230V

208V

Com

SEE

NO

TE 1

NO

T AL

L M

OD

ELS

USE

FU

SE L

INKS

Sing

le S

peed

Fan

Con

trol

Con

nect

Onl

y O

ne F

an L

ead

Not

all

mod

els

have

3 s

peed

s

Blac

k - H

igh

Spee

dBl

ue -

Med

ium

Spe

edR

ed -

Low

Spe

ed

Air H

andl

er (

AHF,

AH

K) w

ith

AW19

10-5

5362

-B1

6, 8

, 10k

W H

eatin

g El

emen

ts

Red

GN

D

L1 L2

ELEM

ENT

HEA

TIN

G

BrownWhite

DIS

CO

NN

ECT

POW

ER B

EFO

RE

INST

ALLA

TIO

N O

R S

ERVI

CIN

G.

MU

LTIP

LE P

OW

ER S

OU

RC

ESM

AY B

E PR

ESEN

T.FA

ILU

RE

TO D

O S

O M

AYC

AUSE

PR

OPE

RTY

DAM

AGE,

PER

SON

AL IN

JUR

Y, O

R D

EATH

.

FAC

TOR

Y W

IRIN

G

NO

TE 1

) Wiri

ng c

hang

e is

requ

ired

to c

onve

rt tra

nsfo

rmer

to 2

08 V

olts

.D

isco

nnec

t pow

er.

Dis

conn

ect o

rang

e hi

gh v

olta

ge le

ad a

nd p

lace

on

term

inal

labe

led

as "2

08V"

for 2

08 V

olts

pow

er.

WIR

ING

TAB

LE

HIG

H V

OLT

AGE

WIR

ING

LOW

VO

LTAG

E W

IRIN

G

FIEL

D W

IRIN

G

CO

NSU

LT N

ATIO

NAL

CO

DE

FOR

PR

OPE

R W

IRE

SIZE

.

TER

MIN

AL B

LOC

K/

208-

230/

60/1

CIR

CU

IT N

O.1

DIS

CO

NN

ECT

M4M3

M2M1Black

Blue

Black

Blue

Yello

w

Blue

FUSE

LIMIT

LINK

FUSELINK

GreenBlue

Ora

nge

Blue

Blue

Blac

kBl

ack

Blue

LIMIT

ELEM

ENT

HEA

TIN

G

White

M4M3

M2M1

Blac

k

*AW

1910

-553

62-B

1*

24V

CLA

SS 2

Wiri

ng

24 6

5 13

FAN

REL

AY

24 6

5 13

IND

OO

RM

OTO

R

Purp

le

RedBlue

RedBl

ack

Brow

n/W

hite

Brow

n

Red

Gre

enGreen

Purp

leBlue

Whi

te

Blac

k

Blue

Blac

k

Black

Y

Out

door

5-W

ire T

herm

osta

t Wiri

ng- C

term

inal

con

nect

s to

com

mon

4-W

ire T

herm

osta

t Wiri

ng- C

term

inal

not

nee

ded

**

**

Uni

t

See

Not

e 2

NO

TE 2

) Br

own

and

Whi

te w

ires

are

used

for H

eat K

its o

nly.

Page 8: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

WIRING DIAGRAM

24 6

5 13

FAN

REL

AY

24 6

5 13

L1L2

GN

D

WG

RC

Y

THER

MO

STAT

Gre

en

Red

Purp

le

TRAN

SFO

RM

ER24V

TER

MIN

ALBL

OC

K

USE

CO

PPER

CO

NN

ECTO

RS

ON

LY.

Use

Con

duct

ors

Suita

ble

for 1

67 D

eg F

.20

8-23

0VAC

/ 60

Hz

/ 1Ph

EQU

IPM

ENT

GR

OU

ND

USE

CO

PPER

OR

ALU

MIN

UM

WIR

E.

DIS

CO

NN

ECT

POW

ER B

EFO

RE

INST

ALLA

TIO

N O

R S

ERVI

CIN

G.

MU

LTIP

LE P

OW

ER S

OU

RC

ESM

AY B

E PR

ESEN

T.FA

ILU

RE

TO D

O S

O M

AYC

AUSE

PR

OPE

RTY

DAM

AGE,

PER

SON

AL IN

JUR

Y, O

R D

EATH

.

230V

208V C

om

AW20

02-5

5444

-C1

Air H

andl

er -

No

Hea

t

SEE

NO

TE 1

Black

BlackR

ed

Yellow

Yellow

Purple

Gre

en

With

CTM

Con

trol &

ComL2L1 Cool

HeatCool

CTM

CO

NTR

OL

Heat

24V

Com

Ora

nge

Blue

Yello

wR

ed

Blac

k

Black

Red

Blue

Blue

Red

Red

24V

CLA

SS 2

Wiri

ng

Red

Yello

wPu

rple

Yello

w

Out

door

Uni

t

FAC

TOR

Y W

IRIN

G

NO

TE 1

) Wiri

ng c

hang

e is

requ

ired

to c

onve

rt tra

nsfo

rmer

to 2

08 V

olts

.D

isco

nnec

t pow

er.

Dis

conn

ect o

rang

e hi

gh v

olta

ge le

ad a

nd p

lace

on

term

inal

labe

led

as "2

08V"

for 2

08 V

olts

pow

er.

WIR

ING

TAB

LE

HIG

H V

OLT

AGE

WIR

ING

LOW

VO

LTAG

E W

IRIN

G

FIEL

D W

IRIN

G

CO

NSU

LT N

ATIO

NAL

CO

DE

FOR

PR

OPE

R W

IRE

SIZE

.

5-W

ire T

herm

osta

t Wiri

ng- C

term

inal

con

nect

s to

com

mon

4-W

ire T

herm

osta

t Wiri

ng- C

term

inal

not

nee

ded

**

**

Black

CTM

MO

TORBl

ack

Whi

te

Whi

te

Yello

w/G

reen

Blac

kBl

ue

YellowRed

Orange

Orange

BlackBlack

Blue

CTM

Nan

Fen

g

Wire

Cap

Com

Black

L2XRMR

L1XRMR

Power

Page 9: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

WIRING DIAGRAM

USE COPPER CONNECTORS ONLY.Use Conductors Suitable for 167 Deg F.208-230VAC / 60Hz / 1Ph

EQUIPMENT GROUND USE COPPER ORALUMINUM WIRE.

G R C W

THERMOSTAT

INDOORMOTOR

Purple

Brow

n

White

Ora

nge

XFMR24V

FACTORY

NOTE 1) Wiring change is required to convert transformer to208 Volts. Disconnect power. Disconnect orange highvoltage lead and place on terminal labeled as "208V" for 208Volts power.NOTE 2) Brown and White wires are used with Heat Kitsonly.

WIRING TABLE

HIGH VOLTAGE WIRING

LOW VOLTAGE WIRING

FIELD

230V

208VCom

SEENOTE 1

SEE NOTE 2

CONSULT NATIONAL CODE FOR PROPER WIRE SIZE.

Single Speed Fan ControlConnect Only One Fan LeadNot all models have 3 speeds

Black - High SpeedBlue - Medium SpeedRed - Low Speed

GND

L1

L2

M3

M4

M1

M2

Black

ELEMENTHEATING

Red

Blac

k

Blue

Blue

Brow

n

Whi

te

Blac

k

Blue

Blac

k

Blue

DISCONNECT POWER BEFOREINSTALLATION OR SERVICING.MULTIPLE POWER SOURCESMAY BE PRESENT.FAILURE TO DO SO MAYCAUSE PROPERTY DAMAGE,PERSONAL INJURY, OR DEATH.

Blue

BlueBlack

AW1910-55361-C1*AW1910-55361-C1*

Brown/WhiteBrown

Orange

Blue

Black

Blue

Gre

en Red

RedYellow

Purp

le

24V CLASS 2 Wiring

Blac

k

Purp

le

Yello

wPu

rple

COMNCNO

G C R

FAN TIMER

L

p/n 17004

thermostat

w/DELAY

YellowGreen

Purple

Red24 vac

Red

230vac

BLACK

Red

Red

Red

Red

LIM

IT

FUSE

LIN

K

Purple

Black

WhiteBrown

Blue

HEATERRELAY

Air Handler with (ABF, ABK, AHF, AHK)3, 5kW Heating Elements

YY

OutdoorUnit

5-Wire Thermostat Wiring- C terminal connects to common4-Wire Thermostat Wiring- C terminal not needed**

**

Red Red

USE COPPER CONNECTORS ONLY.Use Conductors Suitable for 167 Deg F.208-230VAC / 60Hz / 1Ph

EQUIPMENT GROUND USE COPPER ORALUMINUM WIRE.

G R C W

THERMOSTAT

INDOORMOTOR

Purple

Brow

n

White

Ora

nge

XFMR24V

FACTORY

NOTE 1) Wiring change is required to convert transformer to208 Volts. Disconnect power. Disconnect orange highvoltage lead and place on terminal labeled as "208V" for 208Volts power.NOTE 2) Brown and White wires are used with Heat Kitsonly.

WIRING TABLE

HIGH VOLTAGE WIRING

LOW VOLTAGE WIRING

FIELD

230V

208VCom

SEENOTE 1

SEE NOTE 2

CONSULT NATIONAL CODE FOR PROPER WIRE SIZE.

Single Speed Fan ControlConnect Only One Fan LeadNot all models have 3 speeds

Black - High SpeedBlue - Medium SpeedRed - Low Speed

GND

L1

L2

M3

M4

M1

M2

Black

ELEMENTHEATING

Red

Blac

k

Blue

Blue

Brow

n

Whi

te

Blac

k

Blue

Blac

k

Blue

DISCONNECT POWER BEFOREINSTALLATION OR SERVICING.MULTIPLE POWER SOURCESMAY BE PRESENT.FAILURE TO DO SO MAYCAUSE PROPERTY DAMAGE,PERSONAL INJURY, OR DEATH.

Blue

BlueBlack

AW1910-55361-C1*AW1910-55361-C1*

Brown/WhiteBrown

Orange

Blue

Black

Blue

Gre

en Red

RedYellow

Purp

le

24V CLASS 2 Wiring

Blac

k

Purp

le

Yello

wPu

rple

COMNCNO

G C R

FAN TIMER

L

p/n 17004

thermostat

w/DELAY

YellowGreen

Purple

Red24 vac

Red

230vac

BLACK

Red

Red

Red

Red

LIM

IT

FUSE

LIN

K

Purple

Black

WhiteBrown

Blue

HEATERRELAY

Air Handler with (ABF, ABK, AHF, AHK)3, 5kW Heating Elements

YY

OutdoorUnit

5-Wire Thermostat Wiring- C terminal connects to common4-Wire Thermostat Wiring- C terminal not needed**

**

Red Red

M2park

M1park

COM

NO

XFMR-R

XFMR-C

R

C

G SPEED UP

ບF1 FAN TIMER

W/DELAYRP17005

Color Wire CodeFor Relay 17005

R - RedY - YellowP - PurpleG - GreenB - Black

R

PY

R

B

BG

AW2009-55361-C2 AW2009-55361-C2 AW2009-55361-C2

M2park

M1park

COM

NO

XFMR-R

XFMR-C

R

C

G SPEED UP

ບF1

Color Wire CodeFor Relay 17005

R - RedY - YellowP - PurpleG - GreenB - Black

PY

RR

B

B

AW2009-55361-C2

G

FAN TIMERW/DELAYRP17005

NEW TIME DELAY 17005 - 9.2020

Page 10: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

WIRING DIAGRAM

CO

MN

CN

O

GC

R

FAN

TIM

ER

L

p/n

1700

4

ther

mos

tat

w/D

ELAY

Yello

wG

reen

Purp

le Red

24 v

ac

Red

230

vac

BLAC

K

Red

Blac

k

24V

Use

Con

duct

ors

Suita

ble

for 1

67 D

eg F

.

Red

TRAN

SFO

RM

ER

USE

CO

PPER

CO

NN

ECTO

RS

ON

LY.

EQU

IPM

ENT

GR

OU

ND

USE

CO

PPER

208-

230V

AC /

60H

z / 1

Ph

OR

ALU

MIN

UM

WIR

E.

230V

208V

Com

SEE

NO

TE 1

NO

T AL

L M

OD

ELS

USE

FU

SE L

INKS

Sing

le S

peed

Fan

Con

trol

Con

nect

Onl

y O

ne F

an L

ead

Not

all

mod

els

have

3 s

peed

s

Blac

k - H

igh

Spee

dBl

ue -

Med

ium

Spe

edR

ed -

Low

Spe

ed

Air H

andl

er (

AHF,

AH

K) w

ith

AW19

10-5

5362

-C1

6, 8

, 10k

W H

eatin

g El

emen

ts

Red

GN

D

L1 L2

ELEM

ENT

HEA

TIN

G

BrownWhite

DIS

CO

NN

ECT

POW

ER B

EFO

RE

INST

ALLA

TIO

N O

R S

ERVI

CIN

G.

MU

LTIP

LE P

OW

ER S

OU

RC

ESM

AY B

E PR

ESEN

T.FA

ILU

RE

TO D

O S

O M

AYC

AUSE

PR

OPE

RTY

DAM

AGE,

PER

SON

AL IN

JUR

Y, O

R D

EATH

.

TER

MIN

AL B

LOC

K/

208-

230/

60/1

CIR

CU

IT N

O.1

DIS

CO

NN

ECT

M4M3

M2M1Black

Blue

Black

Blue

Yello

w

Blue

FUSE

LIMIT

LINK

FUSELINK

Blue

Ora

nge

Blue

Blue

Blac

kBl

ack

Blue

LIMIT

ELEM

ENT

HEA

TIN

G

White

M4M3

M2M1

Blac

k

*AW

1910

-553

62-C

1*

24V

CLA

SS 2

Wiri

ng

IND

OO

RM

OTO

R

Purp

le

RedBlue

Brow

n/W

hite

Brow

n

Blue

Blac

k

RedRed

Yellow

Blue

Black

Blac

k

Purple

Blac

k

WG

RC

THER

MO

STAT

Gre

en

Purp

le

Red

Whi

te

Y

Out

door

Uni

t

FACT

ORY

WIR

ING

WIR

ING

TABL

E

HIGH

VOL

TAGE

WIR

ING

LOW

VOL

TAGE

WIR

ING

FIEL

D W

IRIN

G

CONS

ULT

NATI

ONAL

COD

E FO

R PR

OPER

WIR

E SI

ZE.

5-W

ire T

herm

osta

t Wiri

ng- C

term

inal

con

nect

s to

com

mon

4-W

ire T

herm

osta

t Wiri

ng- C

term

inal

not

nee

ded

**NO

TE 1

) Wiri

ng c

hang

e is

requ

ired

to c

onve

rt tra

nsfo

rmer

to 2

08 V

olts

.D

isco

nnec

t pow

er.

Dis

conn

ect o

rang

e hi

gh v

olta

ge le

ad a

nd p

lace

on

term

inal

labe

led

as "2

08V"

for 2

08 V

olts

pow

er.

See

Not

e 2

NOTE

2) B

row

n an

d W

hite

wire

s ar

e us

ed w

ith H

eat K

its o

nly.

Red

Red

CO

MN

CN

O

GC

R

FAN

TIM

ER

L

p/n

1700

4

ther

mos

tat

w/D

ELAY

Yello

wG

reen

Purp

le Red

24 v

ac

Red

230

vac

BLAC

K

Red

Blac

k

24V

Use

Con

duct

ors

Suita

ble

for 1

67 D

eg F

.

Red

TRAN

SFO

RM

ER

USE

CO

PPER

CO

NN

ECTO

RS

ON

LY.

EQU

IPM

ENT

GR

OU

ND

USE

CO

PPER

208-

230V

AC /

60H

z / 1

Ph

OR

ALU

MIN

UM

WIR

E.

230V

208V

Com

SEE

NO

TE 1

NO

T AL

L M

OD

ELS

USE

FU

SE L

INKS

Sing

le S

peed

Fan

Con

trol

Con

nect

Onl

y O

ne F

an L

ead

Not

all

mod

els

have

3 s

peed

s

Blac

k - H

igh

Spee

dBl

ue -

Med

ium

Spe

edR

ed -

Low

Spe

ed

Air H

andl

er (

AHF,

AH

K) w

ith

AW19

10-5

5362

-C1

6, 8

, 10k

W H

eatin

g El

emen

ts

Red

GN

D

L1 L2

ELEM

ENT

HEA

TIN

GBrown

White

DIS

CO

NN

ECT

POW

ER B

EFO

RE

INST

ALLA

TIO

N O

R S

ERVI

CIN

G.

MU

LTIP

LE P

OW

ER S

OU

RC

ESM

AY B

E PR

ESEN

T.FA

ILU

RE

TO D

O S

O M

AYC

AUSE

PR

OPE

RTY

DAM

AGE,

PER

SON

AL IN

JUR

Y, O

R D

EATH

.

TER

MIN

AL B

LOC

K/

208-

230/

60/1

CIR

CU

IT N

O.1

DIS

CO

NN

ECT

M4M3

M2M1Black

Blue

Black

Blue

Yello

w

Blue

FUSE

LIMIT

LINK

FUSELINK

Blue

Ora

nge

Blue

Blue

Blac

kBl

ack

Blue

LIMIT

ELEM

ENT

HEA

TIN

G

White

M4M3

M2M1

Blac

k

*AW

1910

-553

62-C

1*

24V

CLA

SS 2

Wiri

ng

IND

OO

RM

OTO

R

Purp

le

RedBlue

Brow

n/W

hite

Brow

n

Blue

Blac

k

RedRed

Yellow

Blue

Black

Blac

k

Purple

Blac

k

WG

RC

THER

MO

STAT

Gre

en

Purp

le

Red

Whi

te

Y

Out

door

Uni

t

FACT

ORY

WIR

ING

WIR

ING

TABL

E

HIGH

VOL

TAGE

WIR

ING

LOW

VOL

TAGE

WIR

ING

FIEL

D W

IRIN

G

CONS

ULT

NATI

ONAL

COD

E FO

R PR

OPER

WIR

E SI

ZE.

5-W

ire T

herm

osta

t Wiri

ng- C

term

inal

con

nect

s to

com

mon

4-W

ire T

herm

osta

t Wiri

ng- C

term

inal

not

nee

ded

**NO

TE 1

) Wiri

ng c

hang

e is

requ

ired

to c

onve

rt tra

nsfo

rmer

to 2

08 V

olts

.D

isco

nnec

t pow

er.

Dis

conn

ect o

rang

e hi

gh v

olta

ge le

ad a

nd p

lace

on

term

inal

labe

led

as "2

08V"

for 2

08 V

olts

pow

er.

See

Not

e 2

NOTE

2) B

row

n an

d W

hite

wire

s ar

e us

ed w

ith H

eat K

its o

nly.

Red

Red

M2pa

rkM1

park CO

M

NO

XFMR

-R

XFMR

-C

R C

GSP

EED

UP

ບ ບF1

R R Y PB

B

G

FAN

TIME

RW

/DEL

AYRP

1700

5C

olor

Wire

Cod

eFo

r Rel

ay 1

7005

R -

Red

Y - Y

ello

wP

- Pur

ple

G -

Gre

enB

- Bla

ck

*AW

2009

-553

62-C

2**A

W20

09-5

5362

-C2*

M2pa

rkM1

park CO

M

NO

XFMR

-R

XFMR

-C

R C

GSP

EED

UP

ບ ບF1

B

R R Y P

G

FAN

TIME

RW

/DEL

AYRP

1700

5

Col

or W

ire C

ode

For R

elay

170

05R

- R

edY

- Yel

low

P - P

urpl

eG

- G

reen

B - B

lack

*AW

2009

-553

62-C

2**A

W20

09-5

5362

-C2*

B

NEW

TIM

E D

ELAY

170

05 -

9.20

20

Page 11: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

WIRING DIAGRAM

NEW

TIM

E D

ELAY

170

05 -

9.20

20

Black

CO

MN

CN

O

GC

R

FAN

TIM

ER

L

p/n

1700

4

ther

mos

tat

w/D

ELAY

Yello

wG

reen Pu

rple

Red

24 v

ac

L1L2

GN

D

WG

RC

Y

THER

MO

STAT

Gre

en

Red

Purp

le

TRAN

SFO

RM

ER24V

TER

MIN

ALBL

OC

K

USE

CO

PPER

CO

NN

ECTO

RS

ON

LY.

Use

Con

duct

ors

Suita

ble

for 1

67 D

eg F

.20

8-23

0VAC

/ 60

Hz

/ 1Ph

EQU

IPM

ENT

GR

OU

ND

USE

CO

PPER

OR

ALU

MIN

UM

WIR

E.

DIS

CO

NN

ECT

POW

ER B

EFO

RE

INST

ALLA

TIO

N O

R S

ERVI

CIN

G.

MU

LTIP

LE P

OW

ER S

OU

RC

ESM

AY B

E PR

ESEN

T.FA

ILU

RE

TO D

O S

O M

AYC

AUSE

PR

OPE

RTY

DAM

AGE,

PER

SON

AL IN

JUR

Y, O

R D

EATH

.

230V

208V C

om

SEE

NO

TE 1

Black

Black

Red

L2L1

HeatCool

CTM

CO

NTR

OL

24V

Com

Ora

nge

Blue

BlackBlack

Blue

Blue

Red

Red

24V

CLA

SS 2

Wiri

ng

Yello

w

OrangeBlue

Orange

Black

Blac

k

Red

Red

Red

Blue

Red

Red

Blac

k

Yello

w

Yello

w

Yellow

Blac

k

Black

Blac

k

Yello

w

Yellow

AW20

02-5

5444

-C2

Air H

andl

er -

No

Hea

tW

ith C

TM C

ontro

l &

Blue Bl

ack

Out

door

Uni

t

FAC

TOR

Y W

IRIN

G

NO

TE 1

) Wiri

ng c

hang

e is

requ

ired

to c

onve

rt tra

nsfo

rmer

to 2

08 V

olts

.D

isco

nnec

t pow

er.

Dis

conn

ect o

rang

e hi

gh v

olta

ge le

ad a

nd p

lace

on

term

inal

labe

led

as "2

08V"

for 2

08 V

olts

pow

er.

WIR

ING

TAB

LE

HIG

H V

OLT

AGE

WIR

ING

LOW

VO

LTAG

E W

IRIN

G

FIEL

D W

IRIN

G

CO

NSU

LT N

ATIO

NAL

CO

DE

FOR

PR

OPE

R W

IRE

SIZE

.

5-W

ire T

herm

osta

t Wiri

ng- C

term

inal

con

nect

s to

com

mon

4-W

ire T

herm

osta

t Wiri

ng- C

term

inal

not

nee

ded

**

**

Red

Red

Red

CTM

MO

TORBl

ack

Whi

te

Whi

te

Yello

w/G

reen

Blac

kBl

ue

YellowRed

Orange

CTM

Nan

-Fen

g

Black

ComL2L1 Cool

HeatCool

CTM

CO

NTR

OL

Heat

24V

Com

Com

L2XRMR

L1XRMR

Power

Black

CO

MN

CN

O

GC

R

FAN

TIM

ER

L

p/n

1700

4

ther

mos

tat

w/D

ELAY

Yello

wG

reen Pu

rple

Red

24 v

ac

L1L2

GN

D

WG

RC

Y

THER

MO

STAT

Gre

en

Red

Purp

le

TRAN

SFO

RM

ER24V

TER

MIN

ALBL

OC

K

USE

CO

PPER

CO

NN

ECTO

RS

ON

LY.

Use

Con

duct

ors

Suita

ble

for 1

67 D

eg F

.20

8-23

0VAC

/ 60

Hz

/ 1Ph

EQU

IPM

ENT

GR

OU

ND

USE

CO

PPER

OR

ALU

MIN

UM

WIR

E.

DIS

CO

NN

ECT

POW

ER B

EFO

RE

INST

ALLA

TIO

N O

R S

ERVI

CIN

G.

MU

LTIP

LE P

OW

ER S

OU

RC

ESM

AY B

E PR

ESEN

T.FA

ILU

RE

TO D

O S

O M

AYC

AUSE

PR

OPE

RTY

DAM

AGE,

PER

SON

AL IN

JUR

Y, O

R D

EATH

.

230V

208V C

om

SEE

NO

TE 1

Black

Black

Red

L2L1

HeatCool

CTM

CO

NTR

OL

24V

Com

Ora

nge

Blue

BlackBlack

Blue

Blue

Red

Red

24V

CLA

SS 2

Wiri

ng

Yello

w

OrangeBlue

Orange

Black

Blac

k

Red

Red

Red

Blue

Red

Red

Blac

k

Yello

w

Yello

w

Yellow

Blac

k

Black

Blac

k

Yello

w

Yellow

AW20

02-5

5444

-C2

Air H

andl

er -

No

Hea

tW

ith C

TM C

ontro

l &

Blue Bl

ack

Out

door

Uni

t

FAC

TOR

Y W

IRIN

G

NO

TE 1

) Wiri

ng c

hang

e is

requ

ired

to c

onve

rt tra

nsfo

rmer

to 2

08 V

olts

.D

isco

nnec

t pow

er.

Dis

conn

ect o

rang

e hi

gh v

olta

ge le

ad a

nd p

lace

on

term

inal

labe

led

as "2

08V"

for 2

08 V

olts

pow

er.

WIR

ING

TAB

LE

HIG

H V

OLT

AGE

WIR

ING

LOW

VO

LTAG

E W

IRIN

G

FIEL

D W

IRIN

G

CO

NSU

LT N

ATIO

NAL

CO

DE

FOR

PR

OPE

R W

IRE

SIZE

.

5-W

ire T

herm

osta

t Wiri

ng- C

term

inal

con

nect

s to

com

mon

4-W

ire T

herm

osta

t Wiri

ng- C

term

inal

not

nee

ded

**

**

Red

Red

Red

CTM

MO

TORBl

ack

Whi

te

Whi

te

Yello

w/G

reen

Blac

kBl

ue

YellowRed

Orange

CTM

Nan

-Fen

g

Black

ComL2L1 Cool

HeatCool

CTM

CO

NTR

OL

Heat

24V

Com

Com

L2XRMR

L1XRMR

Power

M2pa

rkM1

park CO

M

NO

XFMR

-R

XFMR

-C

R C

GSP

EED

UP

ບ ບF1

Blue

R Y P

Purple

Green

B

G

BLU

Col

or W

ire C

ode

For R

elay

170

05R

- R

edY

- Yel

low

P - P

urpl

eG

- G

reen

B - B

lack

BLU

- Bl

ue

FAN

TIME

RW

/DEL

AYRP

1700

5

*AW

2010

-554

44-C

3*

(*)

M2pa

rkM1

park CO

M

NO

XFMR

-R

XFMR

-C

R C

GSP

EED

UP

ບ ບF1

Blue

Green

Purple

G

B

BLU

PYR

*AW

2010

-554

44-C

3*

FAN

TIME

RW

/DEL

AYRP

1700

5

(*)

Col

or W

ire C

ode

For R

elay

170

05R

- R

edY

- Yel

low

P - P

urpl

eG

- G

reen

B - B

lack

BLU

- Bl

ue

ParkPark

Park

*** N

o H

eat E

lem

ents

- C

TM C

ontro

l Par

k Te

rmin

als

are

Not

Use

d

Park

Park

Park

*** N

o H

eat E

lem

ents

- C

TM C

ontro

l Par

k Te

rmin

als

are

Not

Use

d

Page 12: AB* SERIES INSTALLATON GUIDE AIR HANDLER UNITS

9.2020