A WIRELESS- IMPLANTABLE MICRO SYSTEM FOR CONTINUES BLOOD GLUCOSE MONITORING
ANOOP PRoll No:07Reg. No:CTAHEEC013
![Page 2: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/2.jpg)
ABSTRACT
• Remotely powered implantable micro system • Consists of a micro fabricated glucose
biosensor flip-chip bonded to a transponder chip
• Transponder chip measures the output signal of the glucose biosensor and transmits to the external reader
• Chip can measure the sensor output current ranging from 1 nA to 1 A
![Page 3: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/3.jpg)
LITERATURE SURVEY
1. NON-CONTINOUS BLOOD GLUCOSE MONITORING • Consist of a blood glucose meters• small drop of blood is needed to place on
test strip
![Page 4: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/4.jpg)
LITERATURE SURVEY
2. Continues wired blood glucose monitoring• Used conventional electrochemical glucose
sensors• Large sizes• Wired
![Page 5: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/5.jpg)
DESIGN
![Page 6: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/6.jpg)
DESIGN
• Microfabricating the glucose sensor• Inegrating all the interfacing circuits into a
integral chip(TRANSPONDER CHIP)• Attaching the microfabricated glucose sensor
to the transponder chip using flip chip bonding
![Page 7: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/7.jpg)
SYSTEM OVERVIEW AND FUNCTIONING
![Page 8: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/8.jpg)
SYSTEM OVERVIEW AND FUNCTIONING
• Monitoring system consisting of an implantable microsystem and an external reader.
• Microsystem measures the blood glucose concentration and transmits the measured data to the external reader
![Page 9: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/9.jpg)
GLUCOSE SENSOR
• Amperometric electrochemical biosensor• Consists of three electrodes: 1)a working electrode(WE) 2)a reference electrode(RE) 3)a counter electrode(CE)
![Page 10: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/10.jpg)
ELECTRODES
1. WORKING ELECTRODE• Act as a surface on which the electrochemical
reaction takes place between the glucose and an enzymatic layer
• It catalyzes the oxidation of glucose to gluconic acid
![Page 11: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/11.jpg)
ELECTRODES
2. REFERENCE ELECTRODE• The reference electrode is used to measure the
solution (blood or interstitial fluid) potential
![Page 12: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/12.jpg)
ELECTRODES
3. COUNTER ELECTRODE• An inert conductor (gold) that supplies the current
required for the electrochemical reaction
![Page 13: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/13.jpg)
TRANSPONDER CHIP
1. RF FRONT-END BLOCK
![Page 14: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/14.jpg)
TRANSPONDER CHIP
2. DATA-ACQUISITION
![Page 15: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/15.jpg)
EXTERNAL READER
![Page 16: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/16.jpg)
ADVANTAGES
• Small size of the implant• No need of oxygen• Use of passive telemetry link
![Page 17: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/17.jpg)
CONCLUSION
• Miniaturization procedure for a wireless-implantable microsystem for continuous blood glucose monitoring
• Low cost procedure• Microsystem implanted just underneath the
skin
![Page 18: A Wireless- Implantable Micro System](https://reader034.vdocuments.site/reader034/viewer/2022052306/546ea249b4af9f76178b4aa5/html5/thumbnails/18.jpg)
REFERENCES
• IEEE Trans.Biomed. Eng., vol. 35, no. 7, pp. 526–532, Jul. 1988.
• IEEE Trans. Biomed.Eng., vol. 41, no. 10, pp. 937–942, Oct. 1994.
• Biosensors Bioelectron., vol. 10, pp. 485–494, 1995