http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 2/46

Internal Use

Chapter 1 Entering the Maintenance Console

Chapter 2 Operations on the Maintenance Console

Page 3: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 3/46

Internal Use

How to Access Maintenance Console

In Huawei GSM OMC SHELL window, select the object icon

and right click to pop up the maintenance menu.

Page 4: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 4/46

Internal Use

Chapter 1 Entering the Maintenance Console

Chapter 2 Operations on the Maintenance Console

Page 5: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 5/46

Internal Use

Operations on Maintenance Console

Checking equipment status

Operation status of 

modules

Operation status of 

boards

CPU occupations

status

Status of CCS7 links

Status of LAPD links

Status of circuits

Locating faults

Interface tracing

Signaling tracing

Switchover 

Board resetting Module resetting

Page 6: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 6/46

Internal Use

Chapter 2 Operations on the

Maintenance Console 

Section 1 Checking equipment status

Section 2 Locating faults

Page 7: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 7/46Internal Use

Checking equipment status

1. Operation status of modules

 Access: [Maintenance/Module State]

Functions: display the communication state between the

maintenance console and each BM of the BSC

Results:

in normal conditions, module numbers will be displayed.

If the communication is faulty, a * will be placed before the

module.

Page 8: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 8/46Internal Use

Checking equipment status

2. Operation status of boards

 Access: [control/Equipment]

Functions: view and query board state and information,

reset board

Results :

in normal conditions, boards on the interface are in grey,green (active) and blue (standby).

if the board is faulty, color shown on the panel will

change to red.

Caution: if you find a board is in red, first you should confirm it has been

configured or not, then for GALM in AM you should check whether connected

alarmbox has been powered on.

Page 9: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 9/46Internal Use

Checking equipment status

Page 10: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 10/46Internal Use

Checking equipment status

Query MPU

Page 11: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 11/46Internal Use

Checking equipment status

Query GCKS

Page 12: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 12/46Internal Use

Checking equipment status

3. CPU occupation status

 Access: [trace/occupation ratio]

Functions: by viewing CPU occupation ratio, the BSC load

condition (Normal, Overload and Congestion) can be known.

Results:

In normal conditions, the occupation status of CPU andmemories should be displayed in the system performance

tracing window. When the bar chart is blue, the status is

normal.

If the bar chart is yellow, the status is overloaded and red,

congested.

Page 13: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 13/46Internal Use

Check equipment status

Page 14: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 14/46Internal Use

Check equipment status

4. Status of CCS7 links  Access: [SS7 Maintenance/State Query] Functions: query the signaling link state, destination state and

route state to ensure the interworking of inter-office SS7 Interface:

Module number Link number 

Page 15: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 15/46Internal Use

Check equipment status

Query input parameters

Data configuration \ view data configuration work mode\Module 0 \ Hardware \ [E3M Board property]

Page 16: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 16/46Internal Use

Check equipment status

Results:

In normal conditions

Page 17: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 17/46Internal Use

Check equipment status

5. Status of LAPD links  Access: [Control\LAPD Link Maintenance]

Functions: query LAPD link to check current link state

Interface:

Module number 

Start link no, end link no

Page 18: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 18/46Internal Use

Check equipment status

Query input parameters

Data management\site\[site description table]---OML

Page 19: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 19/46Internal Use

Check equipment status

Query input parameters

Data management\local-office\[TRX configuration table]---RSL

Page 20: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 20/46Internal Use

Check equipment state

Results: In normal conditions, the query result should be multi frame

establish state

If TEI has not allocate state, the link has not been

configured; If TEI has allocated state, the link has been

configured, but board is not inserted; if off-link state, theestablished link is disconnected and system cannot operate

at that time. Or the link is configured and board is inserted,

but they are not connected to the BTS

Page 21: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 21/46Internal Use

Check equipment state

Results: In normal conditions, the query result should be multi frame

establish state

If TEI has not allocate state, the link has not been

configured; If TEI has allocated state, the link has been

configured, but board is not inserted; if off-link state, theestablished link is disconnected and system cannot operate

at that time. Or the link is configured and board is inserted,

but they are not connected to the BTS

Page 22: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 22/46

Internal Use

Check equipment status

Page 23: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 23/46

Internal Use

Check equipment status

6. Circuit status  Access: [ control\circuit\circuit state]

Functions: query the state of channel of TC, BIE and PBIE circuits

Interface:

Module number 

Circuit type

Start channel, end channel

Page 24: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 24/46

Internal Use

Check equipment status

Results:

In normal conditions, state should be uninstalled, idle and busy

Page 25: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 25/46

Internal Use

Chapter 2 Operations on the

Maintenance Console

Section 1 Checking equipment status

Section 2 Locating faults

Page 26: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 26/46

Internal Use

Locating faults

1. interface tracing  Access: [trace\GSM interface trace]

Functions: trace messages on A-bis, Um and A interfaces in

real time

interface:

Interface type

Module No.

Page 27: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 27/46

Internal Use

Locating faults

 A interface message trace Filter conditions:

connectionless message, DTAP message, BSSMAP

SCCP No.

Page 28: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 28/46

Internal Use

Locating faults

 A interface message trace

Page 29: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 29/46

Internal Use

Locating faults

 A-bis interface message trace Filter conditions:

BTS number, TRX number, Channel number 

Measurement report, wireless link layer management

message, special channel management message, common

channel management message, TRX managementmessage

Page 30: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 30/46

Internal Use

Locating faults

 A-bis interface message trace

Page 31: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 31/46

Internal Use

Locating fault

Um interface message trace Filter conditions:

BTS number, TRX number, Channel number 

Radio resource management message, MM mobility

management message, Call control and related

Supplementary Services message, UnrelatedSupplementary Service message, SMS short message

Page 32: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 32/46

Internal Use

Locating faults

Um interface message trace

i f l

Page 33: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 33/46

Internal Use

Locating fault

Save tracing message

L ti f lt

Page 34: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 34/46

Internal Use

Locating faults

GSM trace review

L ti f lt

Page 35: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 35/46

Internal Use

Locating faults

2. signaling tracing  Access: [SS7 maintenance\SS7 message trace]

Functions: trace message of a signaling link, capture and save

all or partial message through the signaling link

Interface:

Message type

Filter 

Parameter 

Save to file

L ti f lt

Page 36: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 36/46

Internal Use

Locating faults

SS7 message trace

L ti f lt

Page 37: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 37/46

Internal Use

Locating faults

SS7 Trace review

L ti f lt

Page 38: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 38/46

Internal Use

Locating faults

3. switchover   Access: [control\immediate switchover]

Functions: when the active board is faulty or the data of 

active/standby boards are inconsistent, if the boards have not

switched over automatically, it is required to switch over the

active and standby boards immediately, making the normalboard use the correct data and ensure the correctness of the

BSC operational data. After the active and standby boards are

switched over immediately, the original standby board will

become the active board while the original active board become

the standby board

L ti f lt

Page 39: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 39/46

Internal Use

Locating faults

Switchover 

Interface

Switchover board type

Module number 

L ti f lt

Page 40: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 40/46

Internal Use

Locating faults

Switchover 

Locating faults

Page 41: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 41/46

Internal Use

Locating faults

4. board resetting  Access: [control\equipment]

Functions: resetting operations are be performed when some

boards are faulty. Resetting results include “successful  reset”, 

“equipment  fault”,  ”uninstalled”,  “the device can’t be reset” or 

“unexecuted” 

Caution: This operation requires the system setup authority. Do not reset a board

unless it is necessary. 

Locating faults

Page 42: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 42/46

Internal Use

Locating faults

Board resetting

Locating faults

Page 43: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 43/46

Internal Use

Locating faults

5. module resetting  Access: [control\hierarchical reset]

Functions: mainly used to load some modified data that can not

be set online, or as a way of recovery when any problem occurs

during BSC running

Caution: Hierarchical reset operation requires system setting authority. This operation mayaffect system services. Do not perform this operation unless it is necessary. 

Locating faults

Page 44: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 44/46

Internal Use

Locating faults

Module resetting

Interface:

Restart level

Module number 

References

Page 45: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 45/46

Internal Use

References

M900/M1800 Base Station Controller Routine Operation

Manual

1. BSC Maintenance

Page 46: 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

7/27/2019 8.OMD000201 GSM BSC Maintenance Console ISSUE3.0

http://slidepdf.com/reader/full/8omd000201-gsm-bsc-maintenance-console-issue30 46/46

Huawei Confidential. All Rights Reserved