877-774-3370 access equipment exploring options for working safely
TRANSCRIPT
877-774-3370www.spiderstaging.com
Access Equipment
Exploring Options For Working Safely
877-774-3370www.spiderstaging.com
Agenda
Methods to get to work Responsibilities Code Requirements Quality training Accident prevention programs
877-774-3370www.spiderstaging.com
Access Equipment Choices
ST17 –Single Point Suspended Scaffold The industry standard for work in
refineries, tank farms, shipyards, offshore platforms and heavy construction
Lowering cost of ownership, improving the reliability
Drum hoist Swing stages Boom and scissor lifts Rope access Supported scaffold Ground up scaffold
877-774-3370www.spiderstaging.com
Responsibilities
Employer / Employee Relationship OSHA governs the
Employer/Employee relationship
Employer / Supplier Relationship OSHA does not govern the
Employer/Supplier relationship
877-774-3370www.spiderstaging.com
Requirements
Manufacturers need to provide equipment that complies with OSHA codes
1910.28 (i)(1) 1926.451(d)(13) UL1323 –Design Criteria Recognized Testing lab
UL Underwriters Laboratory FM Approvals Canadian Standards
Associations (CSA) TUV Rheinland
877-774-3370www.spiderstaging.com
Check Before You Buy
Verify UL standards www.UL.com Not all manufactures invests in
UL
Meets or exceeds the applicable OSHA and ANSI standards
Protect your interests by educating yourself before you buy
877-774-3370www.spiderstaging.com
UL Certifications Directory ExampleUL Online Certifications Directory Home Quick Guide Contact Us UL.com TUFV.SA5062
Equipment, Scaffolding Page Bottom
Equipment, ScaffoldingSee General Information for Equipment, Scaffolding
SAFEWORKS L L CSA5062365 UPLAND DR TUKWILA, WA 98188-3802 USA Air-powered drum type hoists Model(s) ST-17 (max rated load 1000 lbs), ST-17-1 (max rated load 1000 lbs), ST-19A (max rated load 1000 lbs), ST-26 (max rated load
1000 lbs) Electrically operated hoists, "Series 10" Model(s) 1000E (max rated load 1000 lbs), 1500E (max rated load 1500 lbs) Electrically operated hoists, "Series PC1" Model(s) PC1-1000E (max rated load 1000 lbs), PC1-1000EC (max rated load 1000 lbs), PC1-1000EDV (max rated load
1000 lbs), PC1-750E (max rated load 750 lbs), PC1-750EC (max rated load 750 lbs), PC1-750EDV (max rated load 750 lbs) Electrically operated hoists, "Series PCN" Model(s) PCN-1000E (max rated load 1000 lbs), PCN-1000EC (max rated load 1000 lbs), PCN-1000EDV (max rated load
1000 lbs), PCN-750EC (max rated load 750 lbs), PCN-750EDV (max rated load 750 lbs) Electrically operated hoists Model(s) Astro 85-3E1500 (max rated load 1500 lbs), Astro 85-3E1500M (max rated load 1500 lbs), Astro 85-3E2000 (max rated load 2000
lbs), Astro 85-E1000 (max rated load 1000 lbs), Astro 85-E1000M (max rated load 1000 lbs), Astro 85-E1500M (max rated load 1500 lbs), Astro 85-E600 (max rated load 600 lbs), Astro 85-E750 (max rated load 750 lbs), Astro 85-EDV1000M (max rated load 1000 lbs), Astro 85-EDV1500M (max rated load 1500 lbs), Astro-85-E1500 (max rated load 1500 lbs), PC3-1000+ (max rated load 1000 lbs), PC3-1500+ (max rated load 1500 lbs), SC1000+ (max rated load 1000 lbs), SC1500+ (max rated load 1500 lbs), ST-180 (max rated load 1250 lbs), ST-180-1 (max rated load 1250 lbs), ST-180-4 (max rated load 1250 lbs), ST-180-5 (max rated load 1250 lbs), ST-19-E (max rated load 1000 lbs)
ST-27 consisting of component parts 27-1 thru 27-6 (max rated load 1500 lbs) Pneumatically operated hoists, "Series 10" Model(s) 1000A (max rated load 1000 lb at 100 psi), 1000A (max rated load 1250 lbs at 120 psi) Pneumatically operated hoists, "Series PC1" Model(s) PC1-1000A (max rated load 1000 lbs at 120 psi) PC1-750A (max rated load 1000 lbs at 120 psi) PC1-750A (max rated load 750 lbs at 90 psi) Pneumatically operated hoists, "Series PCN" Model(s) PCN-1000A (max rated load 1000 lbs at 120 psi) PCN-750A (max rated load 750 lbs at 90 psi) Pneumatically operated hoists Model(s) Astro A-1250 (max rated load 1250 lbs at 120 psi) Astro A-2000 (max rated load 2000 lbs at 120 psi) Astro-1000 (max rated load 1000 lbs at 100 psi) PC3A+ (max rated load 1500 lbs at 110 psi) SC1000A+ (max rated load 1500 lbs at 110 psi) Scaffolding equipment, "Spider Modular Platform System" Model(s) MP (Spider Part No. 4968 - contains work platforms, that can be assembled from 3 to 40 ft long,
rated 1000 lbs; or be assembled from 45 to 50 ft long, rated 750 lbs) MP (Spider Part No. 4969 - contains work platforms, that can be assembled from 3 to 40 ft long, rated 1000 lbs; or be assembled from 45 to 50 ft long, rated 750 lbs) MP (Spider Part No. 700755 - contains work platforms, that can be assembled from 3 to 40 ft long, rated 1000 lbs; or be assembled from 45 to 50 ft long, rated 750 lbs) MP (Spider Part No. 707711- contains work platforms, that can be assembled from 3 to 40 ft long, rated 1000 lbs; or be assembled from 45 to 50 ft long, rated 750 lbs) Scaffolding equipment, modular suspended platform systems Model(s) MODULO (simple or cantilevered support from 2 m to 19 m; rated 500, 750, 1000, 1500 or
2000 lbs)
877-774-3370www.spiderstaging.com
Equipment Qualification
ISO 9001:2008
Sustainable quality system in production of equipment - an added layer of protection and 3rd party auditing
UL® 3rd Party Certification
UL examiners regularly inspect equipment during production to verify consistent sustained production as designed and originally tested and listed, driving a safer, more reliable product.
Standard Work Instructions (SWI)
Investment in reliable customer experience regardless of which Spider location provides the equipment - only Spider invests in this
877-774-3370www.spiderstaging.com
Equipment Sourcing
Multiple locations with a large inventory to rent equipment and the capability to support fleet-owned equipment with local parts and repair services
ISO 9001:2008 audited certification of the manufacturer of the equipment – independent verification of quality
Manufacturer as direct supplier for best responsiveness
Certified trainers, technicians and field labor crews to provide project support ranging from supervision only to turnkey labor
Look for
877-774-3370www.spiderstaging.com
Equipment Sourcing Cont.
Products that are 3rd party inspected, such as by Underwriters Laboratory or CUL for better safety
Rental fleet that is thoroughly serviced following each rental to extensively documented standard work instruction – for best total value
Versatile products that stretch your budget to allow repurposing equipment to other jobs
Reputation – ask about supplier performance, talk to current customers
Longevity – there’s no better credential for the suppliers into a risk-intense environment. Staying power matters
877-774-3370www.spiderstaging.com
Use Appropriate Safety Systems
Each type of access equipment has unique safety requirements Example: Drum hoist and ST17 Every hoist is required to have both
an Overload and an Overspeed safety system
Brakes must be dual action 1926.451 requirement for brakes to
engage when either an accelerated overspeed or a shock force is applied
Fall Protection is required with man-lifts/boom lifts
Suspended scaffolds must have a PFAS & Independent Lifelines
877-774-3370www.spiderstaging.com
Quality training
Competent Person Training Need to meet OSHA standards
& provides suspended scaffold operations training on hazard awareness & mitigation, fall protection, & rigging
Industrial courses focus on rigging & hoist operation & use in industrial applications
877-774-3370www.spiderstaging.com
Accident Prevention Programwith Pre- planning
Worker training Hazard recognition Safe rigging practices Communication Basic self-rescue Understand assisted rescue concept
Mitigate Risk 100% Fall Protection Qualified and Competent Person roles clearly defined and followed Scheduled daily inspections Regular maintenance of all equipment Site-specific rescue plan prior to starting
877-774-3370www.spiderstaging.com
‘Prompt’ Response is Criticalfor Risk at Heights
What is your current plan? Account for specific job site rules Be proactive - site specific fall protection
plan Plans must be in place before start work Find out if there’s compliance space or
restricted access area Be prepared for remote area that you
can not rely on 911 Typically a quality accident and training
program will include initial training – CPT
Have a formal written safety plan Pre-Task Planning Form (JHA)
877-774-3370www.spiderstaging.com
Questions?
FREE white paper “Seven New Ideas for Working Safely at Height”
http://www.spiderstaging.com/TechDocWhite.aspx