8300 tankgate interface - varec · 8300 tankgate interface ... using a pc with the windows based...

4
For more information visit www.tankgauging.com 8300 TankGate Interface Collect and transmit data from multiple storage tanks to a central system or host using a single tank gauge interface Highlights Connects to various manufacturers’ instruments through industry standard protocols ‐ reducing equipment required for a single system Fully compatible with FuelsManager® ‐ tank inventory management made easy 8300 TGI and tank gauging instrument configuration data can be exported to other applications, such as Microsoft Excel® or Access® ‐ documenting all tank gauge equipment All information obtained can be communicated to the host system for inventory, alarm and control purposes Applications The 8300 series TankGate Interface (TGI) acts as a tank gauge interface for data acquisition and host gateway for tank farm, pipeline or refinery applications. Through the use of plugin interface modules, the 8300 TGI can receive various types of measured data from tank gauging instruments, such as level, temperature, density, water level or alarms. Intelligent Module Architecture Each 8300 TGI has a builtin motherboard and interface module based on the local field protocol or tank gauging instrumentation requirements. The motherboard contains an internal high speed serial data link to enable communication to a central database. Host Communication The 8300 TGI combines with FuelsManager software to provide an extremely cost efficient and reliable tank inventory system that is compatible with a variety of other host systems through the industry standard MODBUS™ protocol. Installation Guidelines The 8300 TGI can be installed in a variety of industrial environments when placed in an optional NEMA 4 Enclosure. System Communications AC Power TankGate Interfaces Field Instruments Network Communications FuelsManager® Expansion Modules Each intelligent interface module contains its own processor for fast and reliable field data scanning. Builtin compatibility of every module makes configuration of the internal 8300 TGI database simple and straightforward. Available Modules: MODBUS Whessoe Varec (Mark/Space) GPE Saab Enraf L&J TankWay (L&J Technologies ‐ Shand & Jurs) Prime Measurement (Barton) Instruments Configuration and Programming Remote programming can be accomplished from the host or locally using a PC with the Windows based configuration program ViewRTU. This tool simplifies configuration and diagnostics, allowing uploading of final equipment configurations. Reports can also be generated via a builtin function to assist in documentation

Upload: doanthuy

Post on 15-Apr-2018

229 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: 8300 TankGate Interface - Varec · 8300 TankGate Interface ... using a PC with the Windows based configuration program ... Serial RS‐233C or RS‐485

For more information visit www.tankgauging.com

8300 TankGate InterfaceCollect and transmit data from multiple storage tanks to a central system or host using a single tank gauge interface

Highlights

• Connects to various manufacturers’ instruments through industry standard protocols ‐ reducing equipment required for a single system

• Fully compatible with FuelsManager® ‐ tank inventory management made easy

• 8300 TGI and tank gauging instrument configuration data can be exported to other applications, such as Microsoft Excel® or Access® ‐ documenting all tank gauge equipment

• All information obtained can be communicated to the host system for inventory, alarm and control purposes

Applications

The 8300 series TankGate Interface (TGI) acts as a tank gauge interface for data acquisition and host gateway for tank farm, pipeline or refinery applications. Through the use of plug‐in interface modules, the 8300 TGI can receive various types of measured data from tank gauging instruments, such as level, temperature, density, water level or alarms.

Intelligent Module Architecture

Each 8300 TGI has a built‐in motherboard and interface module based on the local field protocol or tank gauging instrumentation requirements. The motherboard contains an internal high speed serial data link to enable communication to a central database.

Host Communication

The 8300 TGI combines with FuelsManager software to provide an extremely cost efficient and reliable tank inventory system that is compatible with a variety of other host systems through the industry standard MODBUS™ protocol.

Installation Guidelines

The 8300 TGI can be installed in a variety of industrial environments when placed in an optional NEMA 4 Enclosure.

SystemCommunications

AC Power

TankGateInterfaces

FieldInstruments

NetworkCommunications

FuelsManager®

Expansion Modules

Each intelligent interface module contains its own processor for fast and reliable field data scanning. Built‐in compatibility of every module makes configuration of the internal 8300 TGI database simple and straightforward. Available Modules:

• MODBUS

• Whessoe

• Varec (Mark/Space)

• GPE

• Saab

• Enraf

• L&J TankWay (L&J Technologies ‐ Shand & Jurs)

• Prime Measurement (Barton) Instruments

Configuration and Programming

Remote programming can be accomplished from the host or locally using a PC with the Windows based configuration program ViewRTU. This tool simplifies configuration and diagnostics, allowing uploading of final equipment configurations. Reports can also be generated via a built‐in function to assist in documentation

Page 2: 8300 TankGate Interface - Varec · 8300 TankGate Interface ... using a PC with the Windows based configuration program ... Serial RS‐233C or RS‐485

8300 TGI

108  Varec, Inc.

8300 TankGate Interface System Diagram

FuelsManagerSoftware

Device MODBUS Whessoe Bus MarkSpace GPE SAAB Enraf L&J TankWay

Prime (Barton)

Power supply required Varies ‐ 48V 

@230mA

No 48V @ 230mA 48V AC No No 60V DC No

Total connected devices (per 

channel)

64 (32) 20 (10) 50  20 (10) 16 (8) 20 (10) 50 99

Page 3: 8300 TankGate Interface - Varec · 8300 TankGate Interface ... using a PC with the Windows based configuration program ... Serial RS‐233C or RS‐485

Technical Information 109

TankGate Interface

Technical Specifications

Software Functionality

Operating Conditions

Host Communication

Power 

Mechanical Construction

Certifications and Approval

Optional Enclosures

*Gauge dependent

Product Dimensions

Dimensions of the 8300 TankGate Interface

Motherboard 16‐bit processor with optional intelligent 

communication modules

Intelligent field device communicationSerial RS‐233C or RS‐485

Visual indication 4 LEDs on main board indicate power and 

status

Tank gauge scanning Data acquisition of measured values from 

connected tank gauges

Operating temperature  ‐40 °F to +158 °F (‐40 °C to +70 °C)

Humidity 5 to 95% (non‐condensing)

Ports 2

Type Com #0 : RS‐232C

Com #1 : RS‐232C / RS‐485

Baud rate 9600 baud

Protocol MODBUS™ and E+H RTU protocol

Mode RTU mode, master and slave

Media access Master/Slave

Supply voltage 100 to 240 VAC 50/60Hz

Power consumption 50 VA max. @ 110/220 VAC (500 mA)

Surge protection ANSI/IEEE standardsGas Discharge Tubes (GDTs) and clamping 

diodes on all field inputs, power supply 

inputs and communications channels

Material Aluminum powder coated

Mounting Wall mounted

Terminals Plug‐in type with screw connections

CE

Order Code Description

140061563 16x16x6 in.

140061214 16x16x6 in. with 48VDC supply

7.76"8.03"

4.92"

2.01"

2.80"

0.79"

5.51"

Page 4: 8300 TankGate Interface - Varec · 8300 TankGate Interface ... using a PC with the Windows based configuration program ... Serial RS‐233C or RS‐485

8300 TankGate Interface

Varec, Inc., 5834 Peachtree Corners East, Peachtree Corners (Atlanta), GA 30092 USA

Tel: +1 (770) 447‐9202 | Toll Free: +1 (866) 698‐2732 | Fax: +1 (770) 662‐8939 | www.varec.com2013 © Varec, Inc. All Rights Reserved. This document is for information purposes only. Varec, Inc. makes no warranties, express or implied, in 

this summary. The names of actual companies and products mentioned herein may be the trademarks of their respective owners.

Document Code: TEC010GVAE4013

Order Codes

Note! 1: If 'No Enclosure' is selected, then 'No DC Power Supply' must be selected.

Note! 2:  Not available for Mark/Space or Current Loop Interface Modules unless 'No Enclosure' option selected

Note! 3: Not available for SAAB, Enraf, L&J Tankway, Prime Mea‐surement, or Veeder Root (TLS 350) Interface Modules

Note! 4: Only available with Dual RS 485 Interface Modules with enclosure

10 Interface Module

032 Dual RS‐485  MODBUS™ Communications Interface Module

036 Dual RS‐485  GSI ASCII  Communications Interface Module

101 Varec Mark/Space Micro 4‐wire (Varec 1800, 1900, 6500) Interface Module

111 Current Loop (Whessoe Bus) Interface Module

112 Current Loop (GPE) Interface Module

120 SAAB (TRL/2) Interface Module

140 Enraf (811, 802/812, 854, 873) Interface Module

150 L&J Tankway (MCG 1000, MCG 1500, MCG 2000) Interface Module

161 Prime Measurement (3500 ATG) Interface Module

171 Dual RS‐232 Veeder Root (TLS 350) Interface Module 

20 Enclosure

A No Enclosure (Note 1)

B 16x16x6 inch NEMA 4 enclosure

30 Power Supply

0 No DC Power Supply (Note 1, 2)

1 120VAC input, 48VDC, 1 Amp Power Supply (Note 3)

2 240VAC input, 48VDC, 1 Amp Power Supply (Note 3)

3 120VAC input, 24VDC, 1 Amp Power Supply (Note 3, 4)

4 240VAC input, 24VDC , 1 Amp Power Supply (Note 3, 4)

N83 Complete product designation