81-105
TRANSCRIPT
Industrial lighting
GE Consumer & Industrial 81Lighting
GE Consumer & Industrial 81Lighting
Versabeam 85
Filterglow 86
Lowmount 88
Conserva 90
OMG Omniglow 92
GHPB 95
Hiper 99
VSG Versaglow 101
GGD Garage Gard 103
VSG Versaglow 101
GGD Garage Gard 103
Compak 84
Eurobay 82
Hiper 99
OMBS Omnibeam 97OMBS Omnibeam 97
GE Consumer & Industrial 82Lighting
Eurobay luminaires for interior application feature a low-profile design andcan be equipped with high pressure mercury vapour, sodium or metal halidelamps of up to 400 W. Version “CD” is also available, where an additional halogen lamp will light up and operate as long as the main discharge lampcan reach its rated power at switch on.Ideal for industrial and commercialenvironments, with medium-high installation heights.Main body: die-cast aluminium body with slide-adjustable steel suspensionhook for balancing the fitting.Wiring box: connected to the main body and made from fibreglass-reinforced engineering polymer thermoplastic. The wiring box contains the lamp operating components, which are mounted on a removable galvanised steel plate.Accessed by way of a hinged door fitted with a neoprene gasket and securedby four stainless steel screws.Cable inlet: The wiring box is fitted with a nylon PG13.5 cable gland for cablediameters of 9 to 12.5 mm.Reflector: 99.85% anodised, mirror-finish aluminium reflector ideal for clearbulbs. The reflector is fitted with a silicone gasket and secured to the main body byfour screws. Designed to fit a wire guard and protective glass.Lampholder: plastic E40 version. The lampholder can be adjusted in 4 different positions to optimise light distribution in relation to the type of lampused and the installation height.
ACCESSORIESProtective glass EBV: tempered glass fixed to the reflector by three stainlesssteel clips; supplied with safety chain attached to the main body. Wire guard EBG: galvanised steel wire guard used in conjunction with the protective glass, and supplied complete with safety chain.Diffuser EBD: UV-stabilized, self-extinguishing V0 polycarbonate, fixed by 6clips to the body.
EUROBAY
GE Consumer & Industrial 83Lighting
EUROBAY
200
EBV Protective glass for EBR 2,00 4 112 33687
EBG Wire guard for EBR 0,40 4 112 33688
EBG Diffusor for EBRD 1,15 4 40 92304
Weight Pack Qty. ProductType Lamp (kg) Box Pallet Code
Accessories
EUROBAY
EBR Reflector 1,20 4 32 33686
EBRD Reflector 0,85 4 16 92305
Reflector
EUROBAY
EB 250 H H250/40 5,2 1 30 90346EB 400 H H400/40 6,3 1 30 90344
EB 250 M ARC250/T/VBU/960/40 5,4 1 30 90343
EB 400 M KRC400/T/VBU/960/40 6,6 1 30 90342
EB 150 S LU150/100/40 4,2 130 90338
EB 250 S LU250/T/40 5,4 1 30 90337
EB 400 S LU400/T/40 7,0 1 30 90339
Weight Pack Qty. ProductType Lamp (kg) Box Pallet Code
EUROBAY Class: With protective front glass IP 65230V 50Hz For open luminaires or
CEI 34.21 / EN 60598-1, IEC 598 luminaires with wire guard IP 23
Body complete with lamp.
EB 250 H CD H250/40 5,4 1 30 90335EB 400 H CD H400/40 6,5 1 30 90334
EB 250 M CD ARC250/T/VBU/960/40 5,6 1 30 90333
EB 400 M CD KRC400/T/VBU/960/40 6,8 1 30 90332
EB 150 S CD LU150/100/40 4,4 1 30 90331
EB 250 S CD LU250/T/40 5,6 1 30 90330
EB 400 S CD LU400/T/40 7,2 1 30 90329
Weight Pack Qty. ProductType Lamp (kg) Box Pallet Code
EUROBAY Class: With protective front glass IP 65230V 50Hz For open luminaires or
CEI 34.21 / EN 60598-1, IEC 598 luminaires with wire guard IP 23
Body complete with principal lamp and an auxiliary 150W halogen lamp.
GE Consumer & Industrial 84Lighting
COMPAK
600
340
20030
Indoor ceiling luminaires for clear bulb high pressure sodium and metal halidelamps of up to 400W.Body: cold-pressed bonderised sheet steel with white stoved polyester powderpaint finish.The two side clamps for mounting on the ceiling are fixed on top. Power supplyunit with power factor correction, terminal block and cable clamp are mountedon a removable galvanised sheet steel located in a compartment. Cover on power supply compartment fixed by two screws with knurled nuts. One side hinged, easily removable white sheet steel frame with expanding rubber gasket holds the tempered front glass (enclosed as a standard accessory) protecting the optics. The other side of the frame is fixed to the bodyby two M5x60 stainless steel screws for protection against fall.Reflector: anodised and polished 99.85% pure hammered aluminium.Lampholder: porcelain E40.Cable entry: through grommet on the top of the luminaire.
Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code
CPC 250 LU250/T/40 275 13,3 1 30939ARC250/T/H/960/E40
CPC 400 KRC400/T/H/960/E40 440 13,5 1 30941CPS 400 LU400/T/40 436 14,9 1 30943
COMPAK Class: I IP 42 230V 50Hz CEI 34.21 / EN 60598-1
HPF = with power factor correction - Without lamp.
Pack ProductType Description Qty. Code
CPG 5 31340
CPL 1 31341
Accessories
Ø 3mm electric welded galvanisedsteel wire guard.Dimensions: 39mm x 36mm.Fixed through 4 threaded bores in frontframe by 4 screws (enclosed).
Aluminium louvre with white paint finish.Dimensions of the grid: 50mm x 50mm.Fitted in the frame, it is mounted by 4screws fixing the protective glass.
Pack ProductType Description Qty. Code
CPV 5 31342
PTL E40 1 31372
Spare parts
4mm thick tempered glass sheet(enclosed) fixed by 2 screws to thefront frame.
Lampholder
GE Consumer & Industrial 85Lighting
VERSABEAMIndoor luminaires in new “bowl shaped” form for 250W and 400W clear bulbhigh-pressure sodium and metal halide lamps. Especially useful for installation of 5-11 m height, in complicated assembly and machinerylayouts and on sites with obstructions.Body: die-cast aluminium ballast housing with electrocoat grey paint finish.It contains 230V 50Hz power supply unit with power factor correction, prepared for quick electronic and mechanic connection to the reflector containing also the lampholder.Threaded hub on top allows quick and safe installation with matching hook(not included). Safety chain provisions available.Optical assembly: basically a die-cast UV stabilised metacrylate refractorwith prismatic finish for optimum light output. Hinged to a circular highpurity aluminium reflector with ALGLAS coating (see page 144) and fastenedto it through gasket by 4 stainless steel latches preventing fall. The lampholder fastened to the reflector, surrounded by a small prismatic parabolic refractor for the maximum optical performances. On the outside,the reflector is provided with positioning element for the quick connecting tothe body. Built-in carbon filter guarantees the optics to remain clean for along time.Safety chain against fall is also available.Lampholder: E40 porcelain.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum ambient temperature: 55°C.Installation height: 5 -11 m.Installation: with die-cast aluminium hook and safety fixing bolts.
Suspension hook
Weight Pack ProductType Description (kg) Qty. Code
HOOKM With seal IP52 0,15 1 31232HOOKMG With seal IP54 0,16 1 31269
787
610
229
Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code
FGS25S LU250/T/40 275 8,80 1 30771FGS40S LU400/T/40 436 9,90 1 30776FGS25MBF MVR250/U/40 275 8,80 1 30788FGS40MBF MVR400/U/40 430 8,80 1 30825
IP 52 gearbox Class: I
230V 50Hz IEC - CEI
HPF = with power factor correction - Without lamp.
117
13
105
SFC3-B SFC-O
Accessories
Safety chainSFC3-B For the body, of. 0,9 m length 0,25 1 31273SFC-O For the reflector 0,10 1 31277
Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code
VBDGEA LU250/400/T/40 610 6,30 1 31337VBDVEA MVR250/U/40 610 6,30 1 31338VBDAEA MVR400/U/40 610 6,30 1 31339
IP 54 reflector - diffuser
Warning: VERSABEAM is not suitable for high-pressure mercury vapour lamps.
GE Consumer & Industrial 86Lighting
FILTERGLOW
Indoor luminaires for max. 1000W clear bulb high-pressure sodium and metalhalide lamps.Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish. It contains 230V 50Hz power supply unit with power factor correction, prepared for quick electronic and mechanic connection to the reflector containing also the lampholder.Threaded hub on the top allows quick and safe installation with matching hook(not included). Safety chain provisions.Reflector: pure aluminium, internally “ALGLAS” covered, clip-fit fastened to thegearbox; tempered cover glass with rubber gasket, suspension hinge and threesafety stainless steel latches for fixing to the reflector. It can be equipped withsafety chain.The E7 version of 448 mm diameter is suitable for discharge lamps of max.400W; the E2 version of 587 mm diameter is suitable for discharge lamp of1000W and can be attached either to the FGL or FGS type gearboxes. Carbonfilter in the upper part preserves the optics from gaseous or vaporous contamination.Lampholder: E40 from porcelain, adjustable in 11 positions according to thetype of lamp used and the desired optical parameters.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum working ambient temperature: 55°C.Wire guard: available on special request, can be attached to the protectiveglass and is available in the WGNH-17E and WGNH-22E versions for the E7 and E2 reflectors, respectively.It is a concentric ring mesh in dia 3 mm zinc-plated steel wire.Installation height: ≥ 6 m.Installation: with die-cast aluminium hook and safety fixing bolts.
GE Consumer & Industrial 87Lighting
FILTERGLOW
762
448
FGS con riflettore E7 FGL con riflettore E2
229
756
587
267
117
13
105
SFC3-B SFC-O
Suspension hook
Accessories
FGS25S LU250/T/40 275 8,80 1 30771FGS40S LU400/T/40 436 9,90 1 30776FGS25MBF MVR250/U/40 275 8,80 1 30788FGS40MBF MVR400/U/40 430 8,80 1 30825FGL01S LU1000/110/T/40 1050 18,20 1 30823FGL01MBF MVR1000/U/40 1050 17,50 1 32254
IP 52 gearbox Class: I
230V 50Hz IEC - CEI
FGS25SW LU250/T/40 275 8,80 1 30772FGS40SW LU400/T/40 436 9,90 1 30785FGS25MBFW MVR250/U/40 275 8,80 1 30800FGS40MBFW MVR400/U/40 430 8,80 1 30832FGL01SW LU1000/110/T/40 1050 18,20 1 30816FGL01MBFW MVR1000/U/40 1050 17,50 1 32253
IP 54 gearbox Class: I
230V 50Hz IEC - CEI
HPF = with power factor correction - Without lamp.
HPF = with power factor correction - Without lamp.
Diameter Weight Pack ProductType Lamp (mm) (kg) Qty. Code
FG05E7 LU250/T/40 448 2,40 1 31305
MVR400/U/40FG03E7 LU400/T/40 448 2,40 1 31307FG01E7 MVR250/U/40 448 2,40 1 31309FG07E2 LU1000/110/T/40 587 3,20 1 31322
MVR 1000/U/40
IP 54 reflector (complete with tempered cover glass)
Weight Pack ProductType Description (kg) Qty. Code
HOOKM With seal IP52 0,15 1 31232HOOKMG With seal IP54 0,16 1 31269
Wire guard
AccessoriesWire guard concentric rings of Ø 3mm zinc-plated steel wire..It can be installed on the protective glass.
Diameter Weight Pack ProductType Lamp (mm) (kg) Qty. Code
WGNH-17E 432 0,34 1 31293WGNH-22E 559 0,45 1 31290
Safety chainSFC3-B For the body, 0,9 m length 0,25 1 31273SFC-O For the reflector 0,10 1 31277
Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code
FGS with E7 reflector FGL with E2 reflector
GE Consumer & Industrial 88Lighting
LOWMOUNT 400
Indoor luminaires for 250W and 400W clear bulb high-pressure sodium andmetal halide lamps. Very versatile for low mounting in either commercial orindustrial applications with installation height of 3-8 m.Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish.It contains 230V 50Hz power supply unit with power factor correction, prepared for quick electronic and mechanic connection to the reflector containing also the lampholder.Threaded hub on the top allows quick and safe installation with matching hook(not included).Safety chain provisions available.Reflector: anodised polished “ALZAK” aluminium covered from the bottom bydie-cast UV-stabilised polycarbonate low luminance prismatic refractor.Carbon filter in the body preserves the optics from the external contaminatingagents. The hinged reflector is fastened to the body through gasket by 2 strong stainless steel latches protecting the lamp against fall.Safety chain provisions available.Lampholder: E40 porcelain.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum working ambient temperature: 55°C.Installation height: 3 - 8 m.Installation: with die-cast aluminium suspension hook and safety fixing bolts.
GE Consumer & Industrial 89Lighting
LOWMOUNT
540
773
381
117
13
105
SFC3-B SFC-O
Suspension hook
Accessories
Weight Pack ProductType Description (kg) Qty. Code
HOOKM With seal IP52 0,15 1 31232HOOKMG With seal IP54 0,16 1 31269
Safety chainSFC3-B For the body, of 0,9 m length 0,25 1 31273SFC-O For the reflector 0,10 1 31277
Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code
L4MD25S LU250/T/40 275 7,50 1 30878L4MD40S LU400/T/40 436 8,60 1 30913L4MD25MBF MVR250/U/40 275 7,50 1 30923L4MD40MBF MVR400/U/40 430 7,60 1 30936
IP 52 gearbox Class: I
230V 50Hz IEC - CEI
HPF = with power factor correction - Without lamp.
HPF = with power factor correction - Without lamp.
L4MD25SW LU250/T/40 275 7,50 1 30879L4MD40SW LU400/T/40 436 8,60 1 30892L4MD25MBFW MVR250/U/40 275 7,50 1 30922L4MD40MBFW MVR400/U/40 430 7,60 1 30930
IP 54 gearbox Class: I
230V 50Hz IEC - CEI
Diameter Weight Pack ProductType Lamp (mm) (kg) Qty. Code
L4MDLE MVR250/U/40 773 4,00 1 31335
L4MDLD other types 773 4,00 1 31333
IP 52 reflector – diffuser
L4MDLEW MVR250/U/40 773 4,00 1 31336L4MDLDW other types 773 4,00 1 31334
IP 54 reflector – diffuser
GE Consumer & Industrial 90Lighting
CONSERVA 250
86
9356
117
13
105
SFC3-B
Indoor luminaires for 70W, 100W and 250W clear bulb high-pressure sodiumand 250W metal halide lamps.Intended for use in either commercial or industrial applications with installationheights of 2-6 m.Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish,with 230V 50Hz power supply unit with power factor correction, lampholderand hinge for fastening the reflector.Hub on the top allows quick and safe electrical and mechanical connection ofthe die-cast aluminium power supply unit box by using a slide. The suspendinghook should be screwed to the power supply unit box.Safety chain provisions available.Reflector: anodised polished “ALZAK” aluminium covered from the bottom bydie-cast UV-stabilised polycarbonate low luminance prismatic refractor fastened by insulating ring to the reflector.The hinged reflector is fastened to the body through gasket by 2 stainless steellatches protecting the lamp against fall.Lampholder: E40 porcelain.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum working ambient temperature: 55°C for 70 and 100W versions; 40°Cfor other versions.Installation heights: 2 - 6 m.Installation: through the power supply unit box by using of die-cast aluminiumsuspending hook.
417
572
318
Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code
MPB79S LU70/90/T12/27 81 2,00 1 30851MPB11S LU100/100/T/40 112 2,30 1 30863MPB25S LU250/T/40 275 3,20 1 30864MPB25MBF MVR250/U/40 268 2,30 1 30865
IP 52 gearbox Clase: I
230V 50Hz IEC - CEI
HPF = with power factor correction - Without lamp.
Diameter Weight Pack ProductType (mm) (kg) Qty. Code
C1SEL 572 2,80 1 31323
IP 54 reflector – diffuser
Suspension hook
Weight Pack ProductType Description (kg) Qty. Code
HOOKM With seal IP52 0,15 1 31232
Power supply boxMPM-3PF With seal IP52 0,33 1 31332
Safety chainAccessories
Weight Pack ProductType Description (kg) Qty. Code
SFC3-B For the body, of 0,9 m length 0,25 1 31273
GE Consumer & Industrial 91Lighting
CONSERVA 400
86
9356
117
13
105
SFC3-B
515
773
318
Indoor luminaires for 250W and 400W clear bulb high-pressure sodium andmetal halide lamps. Intended for use in either commercial or industrial applications with installation heights of 3-8 m.Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish. It contains 230V 50Hz power supply unit with power factor correction, prepared for quick electronic and mechanic connection to the reflector containing also the lampholder.Threaded hub on the top allows quick and safe installation with matching hook(not included).Safety chain provisions available.Reflector: anodised polished “ALZAK” aluminium covered from the bottom bydie-cast UV-stabilised polycarbonate low luminance prismatic refractor containing the”base down” lampholder.Carbon filter in the body preserves the optics from the external contaminatingagents. The hinged reflector is fastened to the body through gasket by 2 strongstainless steel latches protecting the lamp against fall.Lampholder: E40 porcelain.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum working ambient temperature: 40°C.Installation height: 3 - 8 m.Installation: through the power supply unit box by using of die-cast aluminium suspending hook.
Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code
C4S25S LU250/T/40 275 5,40 1 30824C4S40S LU400/T/40 436 6,50 1 30836C4S25MBF MVR250/U/40 275 5,40 1 30849C4S40MBF MVR400/U/40 430 5,50 1 30850
IP 52 gearbox Class: I
230V 50Hz IEC - CEI
HPF = with power factor correction - Without lamp.
Diameter Weight Pack ProductType (mm) (kg) Qty. Code
C4SEL 773 3,70 1 31330
IP 54 reflector - diffuser
Suspension hook
Weight Pack ProductType Description (kg) Qty. Code
HOOKM With seal IP52 0,15 1 31232
Power supply boxMPM-3PF With seal IP52 0,33 1 31332
Safety chainAccessories
Weight Pack ProductType Description (kg) Qty. Code
SFC3-B For the body, of 0,9 m length 0,25 1 31273
GE Consumer & Industrial 92Lighting
Luminaire available in two versions, open and ventilated (OMG) or enclosedsuitable for use in damp environments (OMGC), both for discharge lamps upto 1000 W. Optical assembly available in two sizes: 14” and 18”.
Total reflection prisms.The light hits both surfaces of the prism at 45°, so that the ray is reflected.
APPLICATIONSParticularly suitable for commercial and industrial lighting applications with a mounting height over 4 meters.
Incident lightRayo incidente
Reflected lightRayo reflejado
OMG OMNIGLOW
GE Consumer & Industrial 93Lighting
TECHNICAL CHARACTERISTICS • características técnicas
Available in two sizes: AG5up to 1000 W and AP5 up to400 W. Die-cast aluminiumballast housing, with whitepolyester powder paint fi-nish applied electrostaticallyand cured at 180°C over ananti-corrosion layer.
• • •The socket holder, joined tothe ballast housing, enablesphotometric distribution tobe set in 8 different positionsusing an ordinary screwdri-ver. Porcelain E40 or E27lamp socket according tothe type of lamp used.
Easy installation using a 3/4”NPSC threaded hub, locatedin the housing and resistantto vibration.
Ballast housing • Caja de equipo
Borosilicate glass reflectorwith total reflection prismsin the outer part, available intwo sizes: small (model 14)for lamps up to 400 W andlarge (model 18) for lampsup to 1000 W.White spun aluminium coverconnecting the reflector tothe ballast housing. Theopen version has three rec-tangular windows, whereasthe closed version has agasket to adjust the positionof the ballast housing.
Reflector support frame,made of three steel rodsand a lower zinc plated ringsupporting the glass; therods hold the glass in positi-on, fixing the ring to the top reflector cap.
Tempered protection glass(closed version only) resis-tant to thermal and mecha-nical stress. Fixed in a metalring with gasket it is fittedwith a hinge and two latchesto guarantee easy removal.
EPDM or si l icon gasket ,according to the lamp wat-tage, between the reflectorand the metal parts.Optionally, lamps up to 400W can be supplied with alarge ballast housing AG5capable of supporting a ro-om temperature up to 65°C.For higher temperaturesplease request further information.
•
Optical assembly
•
•
•
•
•
A mm B mm C mm
OMG-14 588 350 608OMGC-14 609 350 629OMG-18 604 470 624OMGC-18 625 470 645
Net weight from approx. 14 to 24 Kg.
Class:Clase: I
IIPP 5522 IIPP 5544
IIPP 2200 IIPP 5544 IIPP 6655
Ballast housingStandard Optional
Optical assemblyOpened Standard enclosed Optional enclosed
MH/HAL 175W 1000WMetal Halide Lamps
HPS/SAP 70W 1000WHigh Pressure Sodium Lamps
MV/VM 250W 1000WMercury Vapor Lamps
OMG OMNIGLOW
GE Consumer & Industrial 94Lighting
1 Ballast housing AG5.2 Ballast housing AP5.3 3/4” NPSC threaded hub (*).4 Socket holder allowing the lamp tobe adjusted to 8 different positions.5 Lamp socket.6 Gasket between top cap and housing(OMGC version only).7 Aluminium reflector cap withwindows only in the opened versions(OMG).8 Borosilicate glass reflector.9 Three steel rods.10 Zinc plated steel support ring.11 Gaskets supporting glass reflector.12 Flat tempered glass door (OMGCversion only).
COMPONENTS
ORDERING INFORMATION
N O T E S
• Always use the large ballast housing (AG5) for 600 W to 1000 W lamps.• When using the large optical assembly (18) with lamps up to 400W, a narrower photometric distribution is achieved.• The MH 1000 W lamps used in the enclosed versions must be of reduced jacket BT 37 type. Optional IP65 (for optical assembly) andIP54 (for ballast housing) available for enclosed versions only.• For electronic emergency devices, fuses, suspension accessories (i.e., HOOKM), etc., please see pages 64-65. They must be orderedseparately.
OMG:Opened
OMGC:Enlosed
14: 350 mm(max 400 W)
18: 470 mm(max 1000W)
AP5:(max 400W)
AG5:(max 1000W)
MH175WMH250WMH400WMH1000WHPS70WHPS100WHPS150WHPS250WHPS400WHPS600WHPS750WHPS1000WMV250WMV400WMV1000W
208 V220 V230 V240 V277 V
50 Hz60 Hz
HPF:High power factor
E: Electronic emergency device
IP 65: Optical assembly IP 65(enclosed version)
IP 54: Ballast housing IP 54(enclosed version)
*R: Ballast reactor type
**S: Magnetic regulator
Luminaire Optical assembly Housing Lamp type Voltage Frequency Power factor Options
OMG 18C AP5 MH400W 220 V 50 Hz HPF R IP 65 IP 54
The standard ballasts are of the following types:MV250W up to 1000W ReactorHPS250W up to 600W ReactorHPS750W, 1000W CWAMH175W up to 1000W CWA
*The following types are also available on request:MH250W, 400W Reactor (Mercury type+Ignitor) **Only for Super High Output long life, MH400W lamp (uses AG5)
OMG OMNIGLOW
GE Consumer & Industrial 95Lighting
APPLICATIONSParticularly suitable for industrial and commercial lightingapplications; mounting height over 4 meters (medium-high).
The socket holder, joined tothe ballast housing, enableson-site adjustment of photo-metric distribution to 5 diffe-rent positions using an ordi-nary screwdriver. PorcelainE40 or E27 lamp socket ac-cording to the type of lampused.
TECHNICAL CHARACTERISTICS
Die-cast aluminium ballasthousing, with grey polyesterpowder paint finish appliedelectrostatically and curedat 180°C over an anti-corro-sion layer.
• • Easy installation using a 3/4”NPSC threaded hub, locatedin the housing and resistantto vibrations.
The optical assembly com-prises an injection moulded,UV stabilised acrylic reflec-tor with total reflection pri-sms, available in two sizes(diameter 413 mm for GHBP-16 and 571 mm for GHBP-22).
Net weight from approx. 9 to 16 Kg.
Optical assembly
IIPP 5522
IIPP 2200
Ballast housing
Class:Clase: I
MH/HAL 250W 400WMetal Halide Lamps
HPS/SAP 150W 400WHigh Pressure Sodium Lamps
MV/VM 250W 400WMercury Vapor Lamps
GHPB
Open and ventilated unit, for discharge lamps up to 250 W(GHBP-16) and up to 400 W (GHBP-22).
GE Consumer & Industrial 96Lighting
GHPBORDERING INFORMATION
NOTES
• In case a bottom enclosure is needed, contact factory.• For electronic emergency devices, fuses, suspension accesories (i.e., HOOKM), etc., They must be ordered separately.
PHOTOMETRIC DATA
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
GHBP-16; Lampholder position / 5; Lamps ST 250
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.490 0.560 0.670 0.730 0.790 0.820 0.8400.30 0.420 0.500 0.610 0.680 0.760 0.790 0.8100.10 0.370 0.450 0.570 0.650 0.730 0.760 0.790
0.50 0.50 0.10 0.460 0.530 0.630 0.690 0.750 0.780 0.7900.30 0.400 0.470 0.590 0.650 0.720 0.750 0.7700.10 0.360 0.430 0.550 0.620 0.700 0.730 0.750
0.30 0.50 0.10 0.440 0.500 0.600 0.660 0.710 0.740 0.7500.30 0.390 0.460 0.560 0.620 0.690 0.720 0.7300.10 0.350 0.420 0.530 0.600 0.670 0.700 0.720
0.70 0.70 0.30 0.630 0.710 0.820 0.880 0.950 0.980 1.0000.50 0.510 0.600 0.730 0.800 0.890 0.930 0.960
0.50 0.70 0.30 0.580 0.650 0.750 0.810 0.860 0.890 0.9000.70 0.10 0.540 0.600 0.690 0.740 0.780 0.800 0.820
SHR NOM 1.90
ULOR 0.133 DLOR 0.778 LOR 0.911
50 88 94 85 91CIE FLUX CODE
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
GHBP-22; Lampholder position / 3; Lamps QE/ME 400
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.510 0.570 0.650 0.700 0.760 0.790 0.8000.30 0.450 0.510 0.600 0.660 0.730 0.760 0.7800.10 0.410 0.470 0.570 0.630 0.700 0.740 0.760
0.50 0.50 0.10 0.480 0.540 0.620 0.660 0.720 0.740 0.7600.30 0.440 0.490 0.580 0.630 0.690 0.720 0.7400.10 0.400 0.450 0.540 0.600 0.670 0.700 0.720
0.30 0.50 0.10 0.460 0.510 0.580 0.630 0.670 0.700 0.7100.30 0.420 0.470 0.550 0.600 0.650 0.680 0.7000.10 0.390 0.440 0.520 0.570 0.630 0.660 0.680
0.70 0.70 0.30 0.640 0.700 0.800 0.850 0.910 0.940 0.9600.50 0.540 0.600 0.7100 0.780 0.850 0.890 0.920
0.50 0.70 0.30 0.590 0.640 0.720 0.770 0.820 0.850 0.8600.70 0.10 0.550 0.600 0.660 0.700 0.750 0.770 0.780
SHR NOM 1.50
ULOR 0.158 DLOR 0.720 LOR 0.878
62 85 92 82 88CIE FLUX CODE
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
GHBP-22; Lampholder position / 5; Lamps ST 400
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.550 0.600 0.680 0.740 0.790 0.810 0.8300.30 0.490 0.550 0.640 0.700 0.760 0.790 0.8100.10 0.460 0.520 0.610 0.670 0.740 0.770 0.790
0.50 0.50 0.10 0.530 0.580 0.660 0.700 0.750 0.780 0.7900.30 0.480 0.540 0.620 0.670 0.730 0.760 0.7700.10 0.450 0.500 0.590 0.650 0.710 0.740 0.760
0.30 0.50 0.10 0.510 0.560 0.630 0.670 0.720 0.740 0.7500.30 0.470 0.520 0.600 0.650 0.700 0.730 0.7400.10 0.440 0.490 0.570 0.630 0.690 0.710 0.730
0.70 0.70 0.30 0.680 0.740 0.830 0.880 0.940 0.960 0.9800.50 0.580 0.640 0.750 0.810 0.880 0.920 0.940
0.50 0.70 0.30 0.630 0.680 0.760 0.810 0.860 0.880 0.8900.70 0.10 0.590 0.630 0.700 0.740 0.780 0.800 0.810
SHR NOM 1.60
ULOR 0.106 DLOR 0.763 LOR 0.869
68 89 95 88 87CIE FLUX CODE
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
GHBP-16; Lampholder position / 4; Lamps ST 70/150
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.610 0.670 0.750 0.800 0.850 0.880 0.8900.30 0.560 0.620 0.710 0.770 0.830 0.860 0.8700.10 0.530 0.590 0.680 0.740 0.810 0.840 0.860
0.50 0.50 0.10 0.600 0.650 0.730 0.780 0.830 0.850 0.8600.30 0.560 0.610 0.700 0.750 0.810 0.830 0.8500.10 0.520 0.580 0.670 0.730 0.790 0.820 0.840
0.30 0.50 0.10 0.580 0.640 0.710 0.760 0.810 0.830 0.8400.30 0.550 0.600 0.680 0.740 0.790 0.810 0.8300.10 0.520 0.570 0.660 0.720 0.770 0.800 0.820
0.70 0.70 0.30 0.750 0.810 0.900 0.950 1.010 1.030 1.0500.50 0.650 0.720 0.820 0.890 0.960 0.990 1.010
0.50 0.70 0.30 0.710 0.760 0.840 0.890 0.940 0.960 0.9700.70 0.10 0.660 0.710 0.770 0.810 0.850 0.870 0.880
SHR NOM 1.50
ULOR 0.048 DLOR 0.850 LOR 0.898
74 93 97 95 90CIE FLUX CODE
GHBP 16: 413 mm (max 250 W)
22: 571 mm (max 400 W)
MH250WMH400WHPS70WHPS100WHPS150WHPS250WHPS400WMV250WMV400W
208 V220 V230 V240 V277 V
50 Hz60 Hz
HPF:High power factor
E: Electronic emergency device
*R: Ballast reactor type
Luminaire Optical assembly Lamp type Voltage Frequency Power factor
Options
GHBP 22 MH400W 220 V 50 Hz HPF
The standard ballasts are of the following types:MV250W, 400W ReactorHPS70W up to 400W ReactorMH250W, 400W CWA
*The following types are also available on request:MH250W, 400W Reactor (Mercury type+Ignitor)
Dimensions in mm
GE Consumer & Industrial 97Lighting
OMBS OMNIBEAM
TECHNICAL CHARACTERISTICS
Die-cast aluminium ballasthousing, with white polyes-ter powder paint finish appli-ed electrostatically and cu-red at 180°C over an anti-corrosion layer.
Easy installation using a 3/4”NPSC threaded hub, locatedin the housing and resistantto vibrations.
Eight-position mountingbracket , allowing differentlight distributions. PorcelainE40 lamp socket.
UV stabilized acrylic prisma-tic reflector.
IP 52
IP 20
Ballast housing
Optical assembly
Net weight from approx. 14 to 21 Kg.
Class: I
MH/HAL 250W 400WMetal Halide Lamps
HPS/SAP 250W 400WHigh Pressure Sodium Lamps
MV/VM 250W 400WMercury Vapor Lamps
APPLICATIONSSuitable for the lighting of commercial areas, as well as applicationssuch as assembly lines, inspection areas, production bays, storageareas, hangars and railway stations, with mounting height over 5 meters.
Luminaire with an open and ventilated acrylic reflector, fordischarge lamps up to 400 W. The unit can be supplied enclosedunder request.
GE Consumer & Industrial 98Lighting
OMG OMNIBEAM
ORDERING INFORMATION
OMBS MH250WMH400WHPS250WHPS400WMV250WMV400W
208 V220 V230 V240 V277 V
50 Hz60 Hz
HPF:High power factor
E: Electronic emergency device
*R: Ballast reactor type
Luminaire Lamp type Voltage Frequency Power factor Options
OMBS MH400W 220V 50Hz HPF
The standard ballasts are of the following types:MV250W, 400W ReactorHPS250W, 400W ReactorMH250W, 400W CWA
* The following types are also available on request:MH250W, 400W Reactor (Mercury type+Ignitor)
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
OMBS; Lampholder position G; Lamps ST 250/400
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.70 0.30 0.700 0.770 0.890 0.950 1.020 1.050 1.0700.50 0.30 0.580 0.660 0.790 0.870 0.950 0.990 1.020
0.10 0.550 0.620 0.730 0.790 0.850 0.880 0.8900.30 0.10 0.490 0.560 0.670 0.740 0.810 0.850 0.870
0.50 0.50 0.30 0.560 0.630 0.750 0.820 0.890 0.920 0.9400.10 0.530 0.600 0.700 0.760 0.820 0.840 0.860
0.30 0.30 0.490 0.570 0.690 0.760 0.850 0.890 0.9100.10 0.480 0.550 0.650 0.720 0.790 0.820 0.840
0.30 0.30 0.10 0.460 0.530 0.630 0.700 0.760 0.790 0.8100.10 0.10 0.430 0.490 0.600 0.670 0.740 0.770 0.790
0.00 0.00 0.00 0.400 0.470 0.570 0.640 0.700 0.730 0.750
SHR NOM 1.7
ULOR 0.080 DLOR 0.866 LOR 0.947
57 88 94 92 95CIE FLUX CODE
PHOTOMETRIC DATA
GE Consumer & Industrial 99Lighting
HIPER
APPLICATIONSParticularly suitable for large areas as supermarkets and shopping malls;mounting height over 4 meters.
TECHNICAL CHARACTERISTICS
Open and ventilated luminaire with flat glass door on request.
Housing in heavy duty steelplate, with polyester powderpaint finish appliedelectrostatically and curedat 180°C over an anti-corrosion layer.
Aluminium faceted reflector.The faceted design reducesand controls the glare of thelamp.
E40 porcelain lamp socket.
IP 20
Net weight from approx. 15 to 18 Kg.
Class: I
Dimensions in mm
MH 250W 400WMetal Halide Lamps
HPS 250W 400WHigh Pressure Sodium Lamps
MV 400WMercury Vapor Lamps
Compact luminaire for discharge lamps up to 400 W with open, ventila-ted optical assembly (can be enclosed on request) which guaranteesextremely effective, low glare lighting thanks to its faceted reflector.
GE Consumer & Industrial 100Lighting
HIPER
ORDERING INFORMATION
PHOTOMETRIC DATA
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
HIPER; Lampholder position: FIXED; Lamps QE 400 - ME 250/400
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.480 0.540 0.630 0.680 0.730 0.750 0.7600.30 0.430 0.500 0.590 0.650 0.710 0.730 0.7400.10 0.390 0.460 0.570 0.630 0.690 0.720 0.730
0.50 0.50 0.10 0.470 0.530 0.620 0.670 0.710 0.730 0.7400.30 0.430 0.490 0.590 0.640 0.700 0.720 0.7300.10 0.390 0.460 0.560 0.620 0.680 0.710 0.720
0.30 0.50 0.10 0.460 0.520 0.610 0.660 0.700 0.720 0.7300.30 0.420 0.480 0.580 0.630 0.690 0.710 0.7200.10 0.390 0.460 0.560 0.620 0.670 0.700 0.710
0.70 0.70 0.30 0.600 0.660 0.760 0.810 0.860 0.880 0.9000.50 0.510 0.580 0.690 0.750 0.820 0.850 0.870
0.50 0.70 0.30 0.570 0.630 0.720 0.760 0.810 0.830 0.8400.70 0.10 0.530 0.580 0.660 0.700 0.740 0.750 0.760
SHR NOM 1.90
ULOR 0.000 DLOR 0.758 LOR 0.758
62 97 100 100 76CIE FLUX CODE
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
HIPER; Lampholder position / FIXED; Lamps ST 250/400
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.540 0.610 0.700 0.750 0.800 0.820 0.8300.30 0.500 0.560 0.670 0.730 0.780 0.800 0.8200.10 0.460 0.530 0.640 0.700 0.760 0.790 0.800
0.50 0.50 0.10 0.540 0.600 0.690 0.740 0.790 0.810 0.8200.30 0.490 0.560 0.660 0.720 0.770 0.790 0.8000.10 0.460 0.530 0.630 0.690 0.750 0.780 0.790
0.30 0.50 0.10 0.530 0.590 0.680 0.730 0.770 0.790 0.8000.30 0.490 0.550 0.650 0.710 0.760 0.780 0.7900.10 0.460 0.520 0.630 0.690 0.750 0.770 0.780
0.70 0.70 0.30 0.670 0.740 0.840 0.890 0.940 0.970 0.9800.50 0.580 0.650 0.770 0.830 0.900 0.930 0.950
0.50 0.70 0.30 0.640 0.700 0.790 0.840 0.890 0.910 0.9200.70 0.10 0.600 0.650 0.730 0.770 0.810 0.820 0.830
SHR NOM 1.40
ULOR 0.000 DLOR 0.823 LOR 0.823
67 99 100 100 82CIE FLUX CODE
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
HIPER; Lampholder position / FIXED; Lamps MC 250/400
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.500 0.560 0.660 0.720 0.760 0.780 0.7900.30 0.440 0.520 0.620 0.690 0.740 0.770 0.7800.10 0.410 0.480 0.590 0.660 0.720 0.750 0.760
0.50 0.50 0.10 0.490 0.550 0.650 0.700 0.750 0.770 0.7800.30 0.440 0.510 0.620 0.680 0.730 0.750 0.7600.10 0.400 0.480 0.590 0.650 0.710 0.740 0.750
0.30 0.50 0.10 0.480 0.540 0.640 0.690 0.740 0.750 0.7600.30 0.430 0.500 0.610 0.670 0.720 0.740 0.7500.10 0.400 0.470 0.580 0.650 0.700 0.730 0.740
0.70 0.70 0.30 0.620 0.690 0.790 0.850 0.900 0.930 0.9400.50 0.520 0.600 0.720 0.790 0.860 0.890 0.910
0.50 0.70 0.30 0.590 0.660 0.750 0.800 0.850 0.870 0.8800.70 0.10 0.550 0.610 0.690 0.730 0.770 0.790 0.790
SHR NOM 1.60
ULOR 0.000 DLOR 0.796 LOR 0.796
60 99 100 100 80CIE FLUX CODE
HIPER MH250WMH400WHPS250WHPS400WMV400W
208 V220 V230 V240 V277 V
50 Hz60 Hz
HPF:High power factor
E: Electronic emergency device
V: With glass door enclosure
*R: Ballast reactor type
**S: Magnetic regulator
Luminaire Lamp type Voltage Frequency Power factor Options
HIPER MH250W 220 V 50 Hz HPF E
The standard ballasts are of the following types:MV400W ReactorHPS250W, 400W ReactorMH250W, 400W CWA
*The following types are also available on request:MH250W, 400W Reactor (Mercury type+Ignitor) **Only for Super High Output, long life, MH400W lamp
GE Consumer & Industrial 101Lighting
VSG VERSAGLOW
APPLICATIONSSuitable for the lighting of classrooms, offices, cafeterias and commercialareas, with mounting heights between 2.2 and 7 meters.
TECHNICAL CHARACTERISTICS
Die-cast aluminium ballasthousing, with grey polyesterpowder paint finish appliedelectrostatically and curedat 180°C over an anti-corrosion layer.
Sliding disconnect, guarantees safe and easyelectrical and mechanicalassembling with the optical.Please request informationon the possibility of installation using a 3/4”threaded hub.
Porcelain E40 or E27 lampsocket, according to thelamp used.
UV stabilised acrylic prismatic refractor (inLEXAN®1 polycarbonate onrequest) offering high visualcomfort thanks to uniformlight distribution over thewhole surface.
IP 42
ØB Net weight from approx. 10 to 16Kg.
Class: I
MH 70W 250WMetal Halide Lamps
HPS 70W 250WHigh Pressure Sodium Lamps
MV 125W 250WMercury Vapor Lamps
A mm ØB mm
VSG-150 311 567
VSG-250 352 768
Enclosed luminaires suitable for damp environments, for discharge lamps upto 250 W (VSG-250) or up to 150 W (VSG-150). The prismatic refractor provides high level of visual comfort in installations with direct-indirect lighting.
GE Consumer & Industrial 102Lighting
VSG VERSAGLOW
ORDERING INFORMATION
NOTES• For electronic emergency devices, fuses, suspension accesories, etc. must be ordered separately.
The standard ballasts are of the following types:MV125W, 250W ReactorHPS70W up to 250W ReactorMH70W up to 150W Reactor (HPS ballast+Ignitor)MH175W, 250W CWA
* The following type is also available on request:MH250W Reactor (Mercury type+Ignitor)
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
VSG-150; Lampholder position: Fixed; Lamps ST 70/150
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.70 0.30 0.480 0.530 0.630 0.690 0.750 0.790 0.8100.50 0.30 0.370 0.430 0.540 0.610 0.690 0.740 0.760
0.10 0.350 0.400 0.490 0.550 0.610 0.650 0.6700.30 0.10 0.290 0.340 0.440 0.500 0.570 0.620 0.640
0.50 0.50 0.30 0.330 0.380 0.470 0.530 0.600 0.640 0.6600.10 0.310 0.360 0.440 0.490 0.550 0.580 0.600
0.30 0.30 0.270 0.320 0.410 0.480 0.560 0.600 0.6300.10 0.260 0.310 0.390 0.450 0.520 0.560 0.580
0.30 0.30 0.10 0.230 0.280 0.350 0.410 0.470 0.500 0.5200.10 0.10 0.200 0.240 0.320 0.380 0.440 0.480 0.510
0.00 0.00 0.00 0.160 0.200 0.260 0.310 0.370 0.400 0.420
SHR NOM 1.5
ULOR 0.265 DLOR 0.539 LOR 0.804
35 66 88 67 80CIE FLUX CODE
POLAR DIAGRAM NORMAL EFFICIENCY
UTILISATION FACTOR - UF (Floor)
CIE FLUX CODE
SPACING HEIGHT RATIO
VSG-250; Lampholder position: Fixed; Lamps ST 250
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.70 0.30 0.480 0.540 0.640 0.700 0.760 0.800 0.8200.50 0.30 0.370 0.440 0.540 0.610 0.700 0.750 0.780
0.10 0.350 0.410 0.500 0.560 0.620 0.660 0.6800.30 0.10 0.290 0.340 0.440 0.510 0.580 0.620 0.650
0.50 0.50 0.30 0.330 0.380 0.470 0.530 0.600 0.640 0.6700.10 0.310 0.360 0.440 0.490 0.550 0.590 0.610
0.30 0.30 0.270 0.320 0.410 0.480 0.560 0.600 0.6300.10 0.260 0.310 0.390 0.450 0.520 0.560 0.580
0.30 0.30 0.10 0.230 0.270 0.350 0.400 0.460 0.500 0.5200.10 0.10 0.200 0.240 0.320 0.370 0.440 0.480 0.500
0.00 0.00 0.00 0.150 0.190 0.250 0.300 0.350 0.390 0.410
SHR NOM 1.6
ULOR 0.304 DLOR 0.525 LOR 0.828
34 65 87 63 83CIE FLUX CODE
PHOTOMETRIC DATA
VSG-150VSG-250
P: Polycarbonate LEXAN
MH70WMH100WMH150WMH175WMH250WHPS70WHPS100WHPS150WHPS250WMV125WMV250W
208 V220 V230 V240 V277 V
50 Hz60 Hz
HPF:High power factor
E: Electronic emergency device
*R: Ballast reactor type
Luminaire Optional refractor Lamp type Voltage Frequency Power factor Options
VSG-150 MH100W 220 V 50 Hz HPF
GE Consumer & Industrial 103Lighting
GGD GARAGE GARD
Lamp Weight Pack Qty ProductType Type (Kg) Box Code
GGD15SA LU150/T/40 7,00 1 17274
GGD15HAL MH150 7,00 1 17275
GGD Class: I IP 20 230V 50Hz IEC - CEI
Luminaire, suitable for use in damp environments 70-100-150W high pressure sodium and metal halide lamps. The special distribution of light throu-gh the prismatic refractor, enables it to be used in area with reduced mountingheights giving excellent illumination on vertical surfaces.Applications Particularly suitable for underground car parks and garages for warehouses,service stations, stairways, working areas and task lighting. Mounting highabove 2.2 meter.Key Features• Body, in die cast aluminium with grey polyester powder paint finish, appliedelectrostaticaly and cured at 180 (C, over an anti-corrotion layer.• Easy installation through a ceiling mounting plate • Ballast housing fitted with an oven-cured white aluminium reflector.
GE Consumer & Industrial 104Lighting
Photometric data
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
§SPACING – HEIGHT RATIO
CPC 400
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.379 0.472 0.511 0.536 0.561 0.574 0.5820.30 0.346 0.447 0.490 0.518 0.547 0.562 0.5720.10 0.322 0.428 0.473 0.503 0.535 0.552 0.563
0.50 0.50 0.10 0.372 0.465 0.503 0.527 0.550 0.562 0.5700.30 0.343 0.443 0.485 0.512 0.538 0.553 0.5620.10 0.321 0.427 0.470 0.498 0.528 0.544 0.555
0.30 0.50 0.10 0.367 0.459 0.495 0.518 0.541 0.552 0.5590.30 0.340 0.440 0.479 0.505 0.531 0.544 0.5530.10 0.319 0.424 0.466 0.494 0.522 0.537 0.546
0.70 0.50 0.20 0.389 0.487 0.533 0.563 0.593 0.609 0.6200.30 0.352 0.458 0.506 0.539 0.574 0.594 0.6070.10 0.325 0.435 0.485 0.520 0.558 0.580 0.595
0.50 0.50 0.20 0.381 0.477 0.519 0.546 0.573 0.588 0.5970.30 0.347 0.451 0.497 0.527 0.558 0.575 0.5860.10 0.323 0.432 0.478 0.510 0.544 0.564 0.576
SHR NOM 2.00 SHR MAX 2.03 SHR MAX TR 2.27
ULOR 0.000 DLOR 0.573 LOR 0.573
CIE FLUX CODE 57 91 98 100 57
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°
90.0° 270.0°
Semipiani C
180150135120
0
225
150
75
300
1530
60
75
90
105
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
CPC 400 + CPG
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.315 0.353 0.402 0.428 0.456 0.470 0.4790.30 0.287 0.326 0.380 0.409 0.440 0.457 0.4680.10 0.266 0.306 0.362 0.393 0.427 0.446 0.459
0.50 0.50 0.10 0.309 0.347 0.395 0.420 0.446 0.460 0.4680.30 0.284 0.323 0.375 0.403 0.433 0.449 0.4600.10 0.265 0.304 0.359 0.389 0.422 0.440 0.452
0.30 0.50 0.10 0.305 0.341 0.387 0.412 0.437 0.451 0.4590.30 0.282 0.319 0.370 0.397 0.426 0.442 0.4520.10 0.264 0.303 0.356 0.385 0.417 0.434 0.445
0.70 0.50 0.20 0.323 0.365 0.420 0.449 0.482 0.499 0.5100.30 0.292 0.334 0.393 0.425 0.462 0.483 0.4970.10 0.269 0.311 0.371 0.406 0.446 0.469 0.484
0.50 0.50 0.20 0.316 0.356 0.408 0.435 0.464 0.480 0.4900.30 0.288 0.329 0.384 0.415 0.449 0.467 0.4790.10 0.267 0.308 0.365 0.398 0.435 0.456 0.469
SHR NOM 2.00 SHR MAX 2.02 SHR MAX TR 2.27
ULOR 0.000 DLOR 0.480 LOR 0.480
CIE FLUX CODE 94 99 99 100 78
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°
90.0° 270.0°
Semipiani C
180150135120
0
150
100
50
200
1530
60
75
90
105
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
CPC 400 + CPL
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.283 0.310 0.346 0.365 0.386 0.397 0.4040.30 0.262 0.290 0.329 0.350 0.374 0.387 0.3960.10 0.247 0.274 0.315 0.338 0.364 0.379 0.388
0.50 0.50 0.10 0.279 0.305 0.340 0.358 0.378 0.388 0.3950.30 0.260 0.287 0.325 0.346 0.368 0.381 0.3890.10 0.246 0.273 0.313 0.335 0.360 0.373 0.382
0.30 0.50 0.10 0.275 0.300 0.334 0.352 0.371 0.381 0.3880.30 0.258 0.284 0.321 0.341 0.363 0.374 0.3820.10 0.245 0.272 0.310 0.331 0.355 0.368 0.377
0.70 0.50 0.20 0.291 0.320 0.361 0.383 0.408 0.421 0.4300.30 0.267 0.297 0.340 0.365 0.393 0.409 0.4200.10 0.250 0.279 0.323 0.349 0.380 0.398 0.410
0.50 0.50 0.20 0.285 0.313 0.351 0.371 0.394 0.406 0.4140.30 0.264 0.292 0.333 0.356 0.381 0.396 0.4050.10 0.248 0.276 0.318 0.342 0.371 0.387 0.397
SHR NOM 1.50 SHR MAX 1.67 SHR MAX TR 1.86
ULOR 0.000 DLOR 0.402 LOR 0.402
CIE FLUX CODE 62 89 97 100 40
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°
90.0° 270.0°
Semipiani C
180150135120
0
150
100
50
200
1530
60
75
90
105
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
CPC 250M
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.514 0.561 0.590 0.619 0.634 0.6430.30 0.486 0.537 0.570 0.603 0.621 0.6320.10 0.464 0.517 0.552 0.589 0.609 0.622
0.50 0.50 0.10 0.506 0.552 0.580 0.607 0.621 0.6300.30 0.482 0.530 0.562 0.593 0.611 0.6210.10 0.462 0.513 0.547 0.582 0.601 0.613
0.30 0.50 0.10 0.499 0.543 0.570 0.596 0.610 0.6190.30 0.477 0.524 0.555 0.585 0.601 0.6110.10 0.459 0.509 0.542 0.575 0.593 0.603
0.70 0.50 0.20 0.531 0.585 0.619 0.655 0.674 0.6860.30 0.497 0.554 0.593 0.633 0.656 0.6700.10 0.471 0.530 0.570 0.614 0.640 0.657
0.50 0.50 0.20 0.520 0.570 0.601 0.633 0.649 0.6600.30 0.490 0.543 0.579 0.615 0.635 0.6470.10 0.467 0.522 0.560 0.599 0.622 0.636
SHR NOM 2.00 SHR MAX 2.10 SHR MAX TR 2.31
ULOR 0.000 DLOR 0.635 LOR 0.635
CIE FLUX CODE 55 91 98 100 63
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°
90.0° 270.0°
Semipiani C
180150135120
0
225
150
75
300
1530
60
75
90
105
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
EB250M1
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.679 0.731 0.759 0.787 0.801 0.8090.30 0.651 0.708 0.739 0.772 0.789 0.7990.10 0.629 0.690 0.723 0.759 0.778 0.790
0.50 0.50 0.10 0.671 0.722 0.747 0.773 0.786 0.7940.30 0.646 0.701 0.731 0.761 0.777 0.7860.10 0.627 0.685 0.716 0.750 0.768 0.779
0.30 0.50 0.10 0.663 0.711 0.736 0.761 0.773 0.7800.30 0.641 0.694 0.722 0.751 0.765 0.7740.10 0.624 0.680 0.709 0.741 0.758 0.767
0.70 0.50 0.20 0.702 0.763 0.796 0.833 0.851 0.8630.30 0.666 0.732 0.769 0.810 0.833 0.8480.10 0.639 0.708 0.747 0.792 0.818 0.834
0.50 0.50 0.20 0.688 0.745 0.774 0.805 0.822 0.8310.30 0.658 0.718 0.752 0.788 0.807 0.8190.10 0.634 0.697 0.733 0.773 0.795 0.809
SHR NOM 0.75 SHR MAX 0.93
ULOR 0.000 DLOR 0.785 LOR 0.785
CIE FLUX CODE 94 99 99 100 78
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
180150135120
0
600
400
200
800
1530
60
75
90
105
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
EB250M4
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.588 0.675 0.720 0.766 0.789 0.8040.30 0.543 0.638 0.690 0.743 0.771 0.7880.10 0.509 0.609 0.664 0.723 0.754 0.774
0.50 0.50 0.10 0.577 0.662 0.706 0.751 0.773 0.7870.30 0.538 0.630 0.680 0.731 0.758 0.7750.10 0.507 0.604 0.657 0.714 0.744 0.762
0.30 0.50 0.10 0.567 0.650 0.693 0.737 0.758 0.7720.30 0.532 0.622 0.671 0.720 0.746 0.7610.10 0.504 0.599 0.651 0.705 0.734 0.751
0.70 0.50 0.20 0.607 0.704 0.756 0.811 0.839 0.8560.30 0.556 0.659 0.717 0.780 0.814 0.8360.10 0.517 0.625 0.686 0.754 0.792 0.817
0.50 0.50 0.20 0.592 0.683 0.732 0.782 0.808 0.8240.30 0.547 0.646 0.700 0.757 0.788 0.8070.10 0.512 0.615 0.673 0.736 0.770 0.792
SHR NOM 0.50 SHR MAX 0.73
ULOR 0.000 DLOR 0.799 LOR 0.799
CIE FLUX CODE 72 98 99 100 79
180150135120
0
300
200
100
400
1530
60
75
90
105
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
EB400M1
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.664 0.735 0.772 0.810 0.829 0.8410.30 0.627 0.705 0.747 0.791 0.814 0.8280.10 0.599 0.681 0.726 0.774 0.800 0.816
0.50 0.50 0.10 0.654 0.724 0.759 0.795 0.813 0.8240.30 0.622 0.697 0.738 0.779 0.800 0.8140.10 0.596 0.676 0.719 0.765 0.789 0.804
0.30 0.50 0.10 0.645 0.712 0.747 0.781 0.799 0.8090.30 0.616 0.689 0.728 0.768 0.788 0.8000.10 0.593 0.670 0.712 0.755 0.778 0.792
0.70 0.50 0.20 0.686 0.767 0.811 0.857 0.881 0.8960.30 0.642 0.728 0.777 0.830 0.859 0.8780.10 0.608 0.698 0.750 0.808 0.840 0.861
0.50 0.50 0.20 0.672 0.747 0.787 0.828 0.850 0.8630.30 0.633 0.714 0.759 0.807 0.832 0.8480.10 0.603 0.687 0.735 0.788 0.817 0.835
SHR NOM 1.00 SHR MAX 1.25
ULOR 0.000 DLOR 0.825 LOR 0.825
CIE FLUX CODE 79 98 99 100 82
180150135120
0
375
250
125
500
1530
60
75
90
105
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
EB400M4
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.612 0.700 0.746 0.792 0.814 0.8280.30 0.568 0.665 0.717 0.769 0.796 0.8130.10 0.534 0.636 0.691 0.749 0.780 0.799
0.50 0.50 0.10 0.601 0.688 0.732 0.776 0.798 0.8110.30 0.562 0.656 0.707 0.756 0.783 0.7990.10 0.531 0.630 0.685 0.740 0.769 0.787
0.30 0.50 0.10 0.591 0.675 0.719 0.761 0.783 0.7960.30 0.556 0.648 0.697 0.745 0.770 0.7850.10 0.528 0.625 0.678 0.730 0.759 0.775
0.70 0.50 0.20 0.633 0.731 0.783 0.837 0.865 0.8830.30 0.581 0.686 0.746 0.807 0.841 0.8620.10 0.542 0.652 0.714 0.781 0.819 0.843
0.50 0.50 0.20 0.617 0.710 0.759 0.808 0.834 0.8490.30 0.572 0.672 0.728 0.783 0.814 0.8320.10 0.537 0.642 0.701 0.762 0.796 0.817
SHR NOM 1.75 SHR MAX 1.81
ULOR 0.000 DLOR 0.821 LOR 0.821
CIE FLUX CODE 48 95 99 100 82
180150135120
0
225
150
75
300
1530
60
75
90
105
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
GE Consumer & Industrial 105Lighting
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
EB400H1
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.564 0.636 0.674 0.713 0.733 0.7450.30 0.526 0.606 0.648 0.693 0.717 0.7320.10 0.497 0.581 0.626 0.676 0.703 0.719
0.50 0.50 0.10 0.554 0.626 0.662 0.699 0.718 0.7300.30 0.520 0.598 0.639 0.682 0.705 0.7190.10 0.494 0.576 0.620 0.668 0.693 0.709
0.30 0.50 0.10 0.545 0.614 0.650 0.686 0.705 0.7160.30 0.515 0.591 0.631 0.672 0.694 0.7070.10 0.491 0.571 0.614 0.659 0.684 0.698
0.70 0.50 0.20 0.582 0.664 0.707 0.755 0.779 0.7940.30 0.538 0.625 0.674 0.728 0.757 0.7760.10 0.504 0.596 0.647 0.705 0.738 0.760
0.50 0.50 0.20 0.568 0.646 0.686 0.728 0.750 0.7640.30 0.530 0.613 0.658 0.707 0.733 0.7490.10 0.500 0.586 0.634 0.688 0.718 0.736
SHR NOM 1.25 SHR MAX 1.36
ULOR 0.000 DLOR 0.737 LOR 0.737
CIE FLUX CODE 65 96 99 100 73
180150135120
0
300
200
100
400
1530
60
75
90
105
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
EB400H4
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.537 0.625 0.672 0.719 0.744 0.7590.30 0.491 0.587 0.640 0.695 0.724 0.7420.10 0.455 0.556 0.613 0.674 0.707 0.727
0.50 0.50 0.10 0.526 0.612 0.658 0.704 0.728 0.7420.30 0.485 0.579 0.631 0.683 0.712 0.7290.10 0.453 0.552 0.607 0.665 0.697 0.716
0.30 0.50 0.10 0.516 0.600 0.645 0.690 0.714 0.7280.30 0.479 0.571 0.622 0.673 0.700 0.7160.10 0.450 0.547 0.601 0.657 0.688 0.705
0.70 0.50 0.20 0.554 0.652 0.705 0.761 0.790 0.8090.30 0.502 0.606 0.666 0.730 0.765 0.7870.10 0.463 0.570 0.634 0.703 0.743 0.768
0.50 0.50 0.20 0.540 0.632 0.682 0.733 0.761 0.7770.30 0.493 0.593 0.649 0.708 0.740 0.7590.10 0.458 0.561 0.621 0.685 0.722 0.744
SHR NOM 1.75 SHR MAX 1.84
ULOR 0.000 DLOR 0.761 LOR 0.761
CIE FLUX CODE 46 88 99 100 76
180150135120
0
150
100
50
200
1530
60
75
90
105
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
EB400S1
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.664 0.735 0.772 0.810 0.829 0.8410.30 0.627 0.705 0.747 0.791 0.814 0.8280.10 0.599 0.681 0.726 0.774 0.800 0.816
0.50 0.50 0.10 0.654 0.724 0.759 0.795 0.813 0.8240.30 0.622 0.697 0.738 0.779 0.800 0.8140.10 0.596 0.676 0.719 0.765 0.789 0.804
0.30 0.50 0.10 0.645 0.712 0.747 0.781 0.799 0.8090.30 0.616 0.689 0.728 0.768 0.788 0.8000.10 0.593 0.670 0.712 0.755 0.778 0.792
0.70 0.50 0.20 0.686 0.767 0.811 0.857 0.881 0.8960.30 0.642 0.728 0.777 0.830 0.859 0.8780.10 0.608 0.698 0.750 0.808 0.840 0.861
0.50 0.50 0.20 0.672 0.747 0.787 0.828 0.850 0.8630.30 0.633 0.714 0.759 0.807 0.832 0.8480.10 0.603 0.687 0.735 0.788 0.817 0.835
SHR NOM 1.00 SHR MAX 1.25
ULOR 0.000 DLOR 0.825 LOR 0.825
CIE FLUX CODE 79 98 99 100 82
180150135120
0
375
250
125
500
1530
60
75
90
105
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
EB400S4
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.612 0.700 0.746 0.792 0.814 0.8280.30 0.568 0.665 0.717 0.769 0.796 0.8130.10 0.534 0.636 0.691 0.749 0.780 0.799
0.50 0.50 0.10 0.601 0.688 0.732 0.776 0.798 0.8110.30 0.562 0.656 0.707 0.756 0.783 0.7990.10 0.531 0.630 0.685 0.740 0.769 0.787
0.30 0.50 0.10 0.591 0.675 0.719 0.761 0.783 0.7960.30 0.556 0.648 0.697 0.745 0.770 0.7850.10 0.528 0.625 0.678 0.730 0.759 0.775
0.70 0.50 0.20 0.633 0.731 0.783 0.837 0.865 0.8830.30 0.581 0.686 0.746 0.807 0.841 0.8620.10 0.542 0.652 0.714 0.781 0.819 0.843
0.50 0.50 0.20 0.617 0.710 0.759 0.808 0.834 0.8490.30 0.572 0.672 0.728 0.783 0.814 0.8320.10 0.537 0.642 0.701 0.762 0.796 0.817
SHR NOM 1.75 SHR MAX 1.81
ULOR 0.000 DLOR 0.821 LOR 0.821
CIE FLUX CODE 48 95 99 100 82
180150135120
0
225
150
75
300
1530
60
75
90
105
cd/klm
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
FGS40S P3
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.497 0.566 0.636 0.671 0.708 0.726 0.7370.30 0.457 0.531 0.607 0.647 0.689 0.711 0.7250.10 0.428 0.503 0.584 0.627 0.673 0.698 0.713
0.50 0.50 0.10 0.489 0.557 0.626 0.659 0.694 0.712 0.7220.30 0.453 0.525 0.600 0.639 0.678 0.700 0.7120.10 0.427 0.501 0.580 0.621 0.665 0.688 0.703
0.30 0.50 0.10 0.482 0.549 0.615 0.648 0.682 0.699 0.7090.30 0.450 0.520 0.593 0.630 0.669 0.689 0.7000.10 0.425 0.498 0.575 0.615 0.657 0.679 0.692
0.70 0.50 0.20 0.510 0.585 0.664 0.704 0.749 0.771 0.7850.30 0.465 0.543 0.627 0.673 0.724 0.751 0.7690.10 0.432 0.511 0.599 0.647 0.703 0.733 0.753
0.50 0.50 0.20 0.500 0.572 0.646 0.683 0.723 0.744 0.7560.30 0.459 0.535 0.615 0.657 0.703 0.727 0.7420.10 0.430 0.507 0.590 0.635 0.685 0.713 0.730
SHR NOM 1.25 SHR MAX 1.47
ULOR 0.000 DLOR 0.726 LOR 0.726
CIE FLUX CODE 69 98 99 100 72
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
180150135120
0
300
200
100
400
1530
60
75
90
105
cd/klm
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
L4MD40S
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.358 0.420 0.511 0.560 0.614 0.642 0.6600.30 0.305 0.368 0.466 0.521 0.583 0.617 0.6390.10 0.267 0.328 0.430 0.488 0.556 0.594 0.619
0.50 0.50 0.10 0.348 0.408 0.498 0.545 0.598 0.626 0.6440.30 0.301 0.362 0.458 0.512 0.572 0.605 0.6270.10 0.265 0.326 0.426 0.482 0.548 0.585 0.609
0.30 0.50 0.10 0.340 0.398 0.485 0.532 0.584 0.612 0.6300.30 0.297 0.356 0.450 0.503 0.561 0.594 0.6140.10 0.264 0.324 0.422 0.477 0.541 0.577 0.600
0.70 0.50 0.20 0.367 0.434 0.533 0.587 0.649 0.682 0.7040.30 0.310 0.376 0.481 0.542 0.612 0.651 0.6780.10 0.269 0.333 0.441 0.504 0.580 0.624 0.654
0.50 0.50 0.20 0.356 0.419 0.513 0.565 0.623 0.654 0.6750.30 0.305 0.368 0.469 0.527 0.592 0.629 0.6530.10 0.267 0.330 0.434 0.494 0.565 0.606 0.633
SHR NOM 2.00 SHR MAX 2.06
ULOR 0.000 DLOR 0.689 LOR 0.689
CIE FLUX CODE 38 77 94 100 68
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
180150135120
0
120
80
40
160
1530
60
75
90
105
cd/klm
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
C4S40S
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.376 0.446 0.550 0.606 0.667 0.699 0.7190.30 0.317 0.388 0.501 0.563 0.634 0.672 0.6960.10 0.274 0.343 0.461 0.528 0.604 0.647 0.675
0.50 0.50 0.10 0.365 0.434 0.536 0.591 0.651 0.682 0.7020.30 0.312 0.382 0.493 0.554 0.621 0.659 0.6830.10 0.272 0.341 0.457 0.522 0.596 0.638 0.665
0.30 0.50 0.10 0.356 0.422 0.522 0.576 0.635 0.666 0.6860.30 0.307 0.375 0.484 0.544 0.610 0.647 0.6700.10 0.271 0.339 0.452 0.516 0.588 0.629 0.654
0.70 0.50 0.20 0.386 0.461 0.574 0.636 0.706 0.743 0.7670.30 0.322 0.397 0.517 0.586 0.665 0.709 0.7390.10 0.276 0.349 0.473 0.545 0.631 0.680 0.713
0.50 0.50 0.20 0.373 0.445 0.553 0.612 0.677 0.713 0.7350.30 0.316 0.388 0.505 0.570 0.644 0.685 0.7110.10 0.274 0.345 0.465 0.534 0.614 0.660 0.690
SHR NOM 2.25 SHR MAX 2.38
ULOR 0.000 DLOR 0.750 LOR 0.750
CIE FLUX CODE 36 77 95 100 75
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
180150135120
0
120
80
40
160
1530
60
75
90
105
cd/klm
POLAR DIAGRAMOF OUTPUT
NORMAL EFFICIENCY
UTILISATION FACTOR – UF (Floor)
CIE FLUX CODE
SPACING – HEIGHT RATIO
VBSD40S
(cd/1000 lm)
REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00
0.70 0.50 0.10 0.512 0.580 0.673 0.721 0.774 0.801 0.8180.30 0.459 0.528 0.629 0.683 0.743 0.776 0.7970.10 0.420 0.489 0.593 0.651 0.717 0.753 0.777
0.50 0.50 0.10 0.502 0.568 0.659 0.706 0.756 0.783 0.8000.30 0.454 0.522 0.620 0.673 0.730 0.762 0.7830.10 0.419 0.486 0.588 0.644 0.708 0.743 0.766
0.30 0.50 0.10 0.493 0.557 0.645 0.691 0.740 0.766 0.7830.30 0.450 0.516 0.611 0.663 0.718 0.749 0.7680.10 0.417 0.483 0.583 0.638 0.698 0.732 0.754
0.70 0.50 0.20 0.526 0.599 0.702 0.757 0.818 0.851 0.8720.30 0.467 0.541 0.649 0.711 0.780 0.819 0.8450.10 0.424 0.496 0.609 0.673 0.748 0.792 0.821
0.50 0.50 0.20 0.514 0.583 0.680 0.731 0.788 0.818 0.8380.30 0.460 0.531 0.635 0.693 0.756 0.792 0.8150.10 0.421 0.492 0.599 0.659 0.729 0.769 0.795
SHR NOM 1.50 SHR MAX 1.64
ULOR 0.000 DLOR 0.835 LOR 0.835
CIE FLUX CODE 51 85 95 100 83
270°
180°
90°
0°
Angoli Gamma
180.0° 0.0°Semipiani C
180150135120
0
225
150
75
300
1530
60
75
90
105
cd/klm
Photometric data