Industrial lighting

Page 2: 81-105

GE Consumer & Industrial 81Lighting

GE Consumer & Industrial 81Lighting

Versabeam 85

Filterglow 86

Lowmount 88

Conserva 90

OMG Omniglow 92

GHPB 95

Hiper 99

VSG Versaglow 101

GGD Garage Gard 103

VSG Versaglow 101

GGD Garage Gard 103

Compak 84

Eurobay 82

Hiper 99

OMBS Omnibeam 97OMBS Omnibeam 97

Page 3: 81-105

GE Consumer & Industrial 82Lighting

Eurobay luminaires for interior application feature a low-profile design andcan be equipped with high pressure mercury vapour, sodium or metal halidelamps of up to 400 W. Version “CD” is also available, where an additional halogen lamp will light up and operate as long as the main discharge lampcan reach its rated power at switch on.Ideal for industrial and commercialenvironments, with medium-high installation heights.Main body: die-cast aluminium body with slide-adjustable steel suspensionhook for balancing the fitting.Wiring box: connected to the main body and made from fibreglass-reinforced engineering polymer thermoplastic. The wiring box contains the lamp operating components, which are mounted on a removable galvanised steel plate.Accessed by way of a hinged door fitted with a neoprene gasket and securedby four stainless steel screws.Cable inlet: The wiring box is fitted with a nylon PG13.5 cable gland for cablediameters of 9 to 12.5 mm.Reflector: 99.85% anodised, mirror-finish aluminium reflector ideal for clearbulbs. The reflector is fitted with a silicone gasket and secured to the main body byfour screws. Designed to fit a wire guard and protective glass.Lampholder: plastic E40 version. The lampholder can be adjusted in 4 different positions to optimise light distribution in relation to the type of lampused and the installation height.

ACCESSORIESProtective glass EBV: tempered glass fixed to the reflector by three stainlesssteel clips; supplied with safety chain attached to the main body. Wire guard EBG: galvanised steel wire guard used in conjunction with the protective glass, and supplied complete with safety chain.Diffuser EBD: UV-stabilized, self-extinguishing V0 polycarbonate, fixed by 6clips to the body.

EUROBAY

Page 4: 81-105

GE Consumer & Industrial 83Lighting

EUROBAY

200

EBV Protective glass for EBR 2,00 4 112 33687

EBG Wire guard for EBR 0,40 4 112 33688

EBG Diffusor for EBRD 1,15 4 40 92304

Weight Pack Qty. ProductType Lamp (kg) Box Pallet Code

Accessories

EUROBAY

EBR Reflector 1,20 4 32 33686

EBRD Reflector 0,85 4 16 92305

Reflector

EUROBAY

EB 250 H H250/40 5,2 1 30 90346EB 400 H H400/40 6,3 1 30 90344

EB 250 M ARC250/T/VBU/960/40 5,4 1 30 90343

EB 400 M KRC400/T/VBU/960/40 6,6 1 30 90342

EB 150 S LU150/100/40 4,2 130 90338

EB 250 S LU250/T/40 5,4 1 30 90337

EB 400 S LU400/T/40 7,0 1 30 90339

Weight Pack Qty. ProductType Lamp (kg) Box Pallet Code

EUROBAY Class: With protective front glass IP 65230V 50Hz For open luminaires or

CEI 34.21 / EN 60598-1, IEC 598 luminaires with wire guard IP 23

Body complete with lamp.

EB 250 H CD H250/40 5,4 1 30 90335EB 400 H CD H400/40 6,5 1 30 90334

EB 250 M CD ARC250/T/VBU/960/40 5,6 1 30 90333

EB 400 M CD KRC400/T/VBU/960/40 6,8 1 30 90332

EB 150 S CD LU150/100/40 4,4 1 30 90331

EB 250 S CD LU250/T/40 5,6 1 30 90330

EB 400 S CD LU400/T/40 7,2 1 30 90329

Weight Pack Qty. ProductType Lamp (kg) Box Pallet Code

EUROBAY Class: With protective front glass IP 65230V 50Hz For open luminaires or

CEI 34.21 / EN 60598-1, IEC 598 luminaires with wire guard IP 23

Body complete with principal lamp and an auxiliary 150W halogen lamp.

Page 5: 81-105

GE Consumer & Industrial 84Lighting

COMPAK

600

340

20030

Indoor ceiling luminaires for clear bulb high pressure sodium and metal halidelamps of up to 400W.Body: cold-pressed bonderised sheet steel with white stoved polyester powderpaint finish.The two side clamps for mounting on the ceiling are fixed on top. Power supplyunit with power factor correction, terminal block and cable clamp are mountedon a removable galvanised sheet steel located in a compartment. Cover on power supply compartment fixed by two screws with knurled nuts. One side hinged, easily removable white sheet steel frame with expanding rubber gasket holds the tempered front glass (enclosed as a standard accessory) protecting the optics. The other side of the frame is fixed to the bodyby two M5x60 stainless steel screws for protection against fall.Reflector: anodised and polished 99.85% pure hammered aluminium.Lampholder: porcelain E40.Cable entry: through grommet on the top of the luminaire.

Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code

CPC 250 LU250/T/40 275 13,3 1 30939ARC250/T/H/960/E40

CPC 400 KRC400/T/H/960/E40 440 13,5 1 30941CPS 400 LU400/T/40 436 14,9 1 30943

COMPAK Class: I IP 42 230V 50Hz CEI 34.21 / EN 60598-1

HPF = with power factor correction - Without lamp.

Pack ProductType Description Qty. Code

CPG 5 31340

CPL 1 31341

Accessories

Ø 3mm electric welded galvanisedsteel wire guard.Dimensions: 39mm x 36mm.Fixed through 4 threaded bores in frontframe by 4 screws (enclosed).

Aluminium louvre with white paint finish.Dimensions of the grid: 50mm x 50mm.Fitted in the frame, it is mounted by 4screws fixing the protective glass.

Pack ProductType Description Qty. Code

CPV 5 31342

PTL E40 1 31372

Spare parts

4mm thick tempered glass sheet(enclosed) fixed by 2 screws to thefront frame.

Lampholder

Page 6: 81-105

GE Consumer & Industrial 85Lighting

VERSABEAMIndoor luminaires in new “bowl shaped” form for 250W and 400W clear bulbhigh-pressure sodium and metal halide lamps. Especially useful for installation of 5-11 m height, in complicated assembly and machinerylayouts and on sites with obstructions.Body: die-cast aluminium ballast housing with electrocoat grey paint finish.It contains 230V 50Hz power supply unit with power factor correction, prepared for quick electronic and mechanic connection to the reflector containing also the lampholder.Threaded hub on top allows quick and safe installation with matching hook(not included). Safety chain provisions available.Optical assembly: basically a die-cast UV stabilised metacrylate refractorwith prismatic finish for optimum light output. Hinged to a circular highpurity aluminium reflector with ALGLAS coating (see page 144) and fastenedto it through gasket by 4 stainless steel latches preventing fall. The lampholder fastened to the reflector, surrounded by a small prismatic parabolic refractor for the maximum optical performances. On the outside,the reflector is provided with positioning element for the quick connecting tothe body. Built-in carbon filter guarantees the optics to remain clean for along time.Safety chain against fall is also available.Lampholder: E40 porcelain.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum ambient temperature: 55°C.Installation height: 5 -11 m.Installation: with die-cast aluminium hook and safety fixing bolts.

Suspension hook

Weight Pack ProductType Description (kg) Qty. Code

HOOKM With seal IP52 0,15 1 31232HOOKMG With seal IP54 0,16 1 31269

787

610

229

Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code

FGS25S LU250/T/40 275 8,80 1 30771FGS40S LU400/T/40 436 9,90 1 30776FGS25MBF MVR250/U/40 275 8,80 1 30788FGS40MBF MVR400/U/40 430 8,80 1 30825

IP 52 gearbox Class: I

230V 50Hz IEC - CEI

HPF = with power factor correction - Without lamp.

117

13

105

SFC3-B SFC-O

Accessories

Safety chainSFC3-B For the body, of. 0,9 m length 0,25 1 31273SFC-O For the reflector 0,10 1 31277

Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code

VBDGEA LU250/400/T/40 610 6,30 1 31337VBDVEA MVR250/U/40 610 6,30 1 31338VBDAEA MVR400/U/40 610 6,30 1 31339

IP 54 reflector - diffuser

Warning: VERSABEAM is not suitable for high-pressure mercury vapour lamps.

Page 7: 81-105

GE Consumer & Industrial 86Lighting

FILTERGLOW

Indoor luminaires for max. 1000W clear bulb high-pressure sodium and metalhalide lamps.Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish. It contains 230V 50Hz power supply unit with power factor correction, prepared for quick electronic and mechanic connection to the reflector containing also the lampholder.Threaded hub on the top allows quick and safe installation with matching hook(not included). Safety chain provisions.Reflector: pure aluminium, internally “ALGLAS” covered, clip-fit fastened to thegearbox; tempered cover glass with rubber gasket, suspension hinge and threesafety stainless steel latches for fixing to the reflector. It can be equipped withsafety chain.The E7 version of 448 mm diameter is suitable for discharge lamps of max.400W; the E2 version of 587 mm diameter is suitable for discharge lamp of1000W and can be attached either to the FGL or FGS type gearboxes. Carbonfilter in the upper part preserves the optics from gaseous or vaporous contamination.Lampholder: E40 from porcelain, adjustable in 11 positions according to thetype of lamp used and the desired optical parameters.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum working ambient temperature: 55°C.Wire guard: available on special request, can be attached to the protectiveglass and is available in the WGNH-17E and WGNH-22E versions for the E7 and E2 reflectors, respectively.It is a concentric ring mesh in dia 3 mm zinc-plated steel wire.Installation height: ≥ 6 m.Installation: with die-cast aluminium hook and safety fixing bolts.

Page 8: 81-105

GE Consumer & Industrial 87Lighting

FILTERGLOW

762

448

FGS con riflettore E7 FGL con riflettore E2

229

756

587

267

117

13

105

SFC3-B SFC-O

Suspension hook

Accessories

FGS25S LU250/T/40 275 8,80 1 30771FGS40S LU400/T/40 436 9,90 1 30776FGS25MBF MVR250/U/40 275 8,80 1 30788FGS40MBF MVR400/U/40 430 8,80 1 30825FGL01S LU1000/110/T/40 1050 18,20 1 30823FGL01MBF MVR1000/U/40 1050 17,50 1 32254

IP 52 gearbox Class: I

230V 50Hz IEC - CEI

FGS25SW LU250/T/40 275 8,80 1 30772FGS40SW LU400/T/40 436 9,90 1 30785FGS25MBFW MVR250/U/40 275 8,80 1 30800FGS40MBFW MVR400/U/40 430 8,80 1 30832FGL01SW LU1000/110/T/40 1050 18,20 1 30816FGL01MBFW MVR1000/U/40 1050 17,50 1 32253

IP 54 gearbox Class: I

230V 50Hz IEC - CEI

HPF = with power factor correction - Without lamp.

HPF = with power factor correction - Without lamp.

Diameter Weight Pack ProductType Lamp (mm) (kg) Qty. Code

FG05E7 LU250/T/40 448 2,40 1 31305

MVR400/U/40FG03E7 LU400/T/40 448 2,40 1 31307FG01E7 MVR250/U/40 448 2,40 1 31309FG07E2 LU1000/110/T/40 587 3,20 1 31322

MVR 1000/U/40

IP 54 reflector (complete with tempered cover glass)

Weight Pack ProductType Description (kg) Qty. Code

HOOKM With seal IP52 0,15 1 31232HOOKMG With seal IP54 0,16 1 31269

Wire guard

AccessoriesWire guard concentric rings of Ø 3mm zinc-plated steel wire..It can be installed on the protective glass.

Diameter Weight Pack ProductType Lamp (mm) (kg) Qty. Code

WGNH-17E 432 0,34 1 31293WGNH-22E 559 0,45 1 31290

Safety chainSFC3-B For the body, 0,9 m length 0,25 1 31273SFC-O For the reflector 0,10 1 31277

Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code

FGS with E7 reflector FGL with E2 reflector

Page 9: 81-105

GE Consumer & Industrial 88Lighting

LOWMOUNT 400

Indoor luminaires for 250W and 400W clear bulb high-pressure sodium andmetal halide lamps. Very versatile for low mounting in either commercial orindustrial applications with installation height of 3-8 m.Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish.It contains 230V 50Hz power supply unit with power factor correction, prepared for quick electronic and mechanic connection to the reflector containing also the lampholder.Threaded hub on the top allows quick and safe installation with matching hook(not included).Safety chain provisions available.Reflector: anodised polished “ALZAK” aluminium covered from the bottom bydie-cast UV-stabilised polycarbonate low luminance prismatic refractor.Carbon filter in the body preserves the optics from the external contaminatingagents. The hinged reflector is fastened to the body through gasket by 2 strong stainless steel latches protecting the lamp against fall.Safety chain provisions available.Lampholder: E40 porcelain.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum working ambient temperature: 55°C.Installation height: 3 - 8 m.Installation: with die-cast aluminium suspension hook and safety fixing bolts.

Page 10: 81-105

GE Consumer & Industrial 89Lighting

LOWMOUNT

540

773

381

117

13

105

SFC3-B SFC-O

Suspension hook

Accessories

Weight Pack ProductType Description (kg) Qty. Code

HOOKM With seal IP52 0,15 1 31232HOOKMG With seal IP54 0,16 1 31269

Safety chainSFC3-B For the body, of 0,9 m length 0,25 1 31273SFC-O For the reflector 0,10 1 31277

Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code

L4MD25S LU250/T/40 275 7,50 1 30878L4MD40S LU400/T/40 436 8,60 1 30913L4MD25MBF MVR250/U/40 275 7,50 1 30923L4MD40MBF MVR400/U/40 430 7,60 1 30936

IP 52 gearbox Class: I

230V 50Hz IEC - CEI

HPF = with power factor correction - Without lamp.

HPF = with power factor correction - Without lamp.

L4MD25SW LU250/T/40 275 7,50 1 30879L4MD40SW LU400/T/40 436 8,60 1 30892L4MD25MBFW MVR250/U/40 275 7,50 1 30922L4MD40MBFW MVR400/U/40 430 7,60 1 30930

IP 54 gearbox Class: I

230V 50Hz IEC - CEI

Diameter Weight Pack ProductType Lamp (mm) (kg) Qty. Code

L4MDLE MVR250/U/40 773 4,00 1 31335

L4MDLD other types 773 4,00 1 31333

IP 52 reflector – diffuser

L4MDLEW MVR250/U/40 773 4,00 1 31336L4MDLDW other types 773 4,00 1 31334

IP 54 reflector – diffuser

Page 11: 81-105

GE Consumer & Industrial 90Lighting

CONSERVA 250

86

9356

117

13

105

SFC3-B

Indoor luminaires for 70W, 100W and 250W clear bulb high-pressure sodiumand 250W metal halide lamps.Intended for use in either commercial or industrial applications with installationheights of 2-6 m.Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish,with 230V 50Hz power supply unit with power factor correction, lampholderand hinge for fastening the reflector.Hub on the top allows quick and safe electrical and mechanical connection ofthe die-cast aluminium power supply unit box by using a slide. The suspendinghook should be screwed to the power supply unit box.Safety chain provisions available.Reflector: anodised polished “ALZAK” aluminium covered from the bottom bydie-cast UV-stabilised polycarbonate low luminance prismatic refractor fastened by insulating ring to the reflector.The hinged reflector is fastened to the body through gasket by 2 stainless steellatches protecting the lamp against fall.Lampholder: E40 porcelain.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum working ambient temperature: 55°C for 70 and 100W versions; 40°Cfor other versions.Installation heights: 2 - 6 m.Installation: through the power supply unit box by using of die-cast aluminiumsuspending hook.

417

572

318

Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code

MPB79S LU70/90/T12/27 81 2,00 1 30851MPB11S LU100/100/T/40 112 2,30 1 30863MPB25S LU250/T/40 275 3,20 1 30864MPB25MBF MVR250/U/40 268 2,30 1 30865

IP 52 gearbox Clase: I

230V 50Hz IEC - CEI

HPF = with power factor correction - Without lamp.

Diameter Weight Pack ProductType (mm) (kg) Qty. Code

C1SEL 572 2,80 1 31323

IP 54 reflector – diffuser

Suspension hook

Weight Pack ProductType Description (kg) Qty. Code

HOOKM With seal IP52 0,15 1 31232

Power supply boxMPM-3PF With seal IP52 0,33 1 31332

Safety chainAccessories

Weight Pack ProductType Description (kg) Qty. Code

SFC3-B For the body, of 0,9 m length 0,25 1 31273

Page 12: 81-105

GE Consumer & Industrial 91Lighting

CONSERVA 400

86

9356

117

13

105

SFC3-B

515

773

318

Indoor luminaires for 250W and 400W clear bulb high-pressure sodium andmetal halide lamps. Intended for use in either commercial or industrial applications with installation heights of 3-8 m.Gearbox: die-cast aluminium ballast housing with electrocoat grey paint finish. It contains 230V 50Hz power supply unit with power factor correction, prepared for quick electronic and mechanic connection to the reflector containing also the lampholder.Threaded hub on the top allows quick and safe installation with matching hook(not included).Safety chain provisions available.Reflector: anodised polished “ALZAK” aluminium covered from the bottom bydie-cast UV-stabilised polycarbonate low luminance prismatic refractor containing the”base down” lampholder.Carbon filter in the body preserves the optics from the external contaminatingagents. The hinged reflector is fastened to the body through gasket by 2 strongstainless steel latches protecting the lamp against fall.Lampholder: E40 porcelain.Power supply: 230V 50Hz, with power factor correction, cos j ≥ 0,9.Maximum working ambient temperature: 40°C.Installation height: 3 - 8 m.Installation: through the power supply unit box by using of die-cast aluminium suspending hook.

Tot. Absorbed Weight Pack ProductType Lamp Power (W) (kg) Qty. Code

C4S25S LU250/T/40 275 5,40 1 30824C4S40S LU400/T/40 436 6,50 1 30836C4S25MBF MVR250/U/40 275 5,40 1 30849C4S40MBF MVR400/U/40 430 5,50 1 30850

IP 52 gearbox Class: I

230V 50Hz IEC - CEI

HPF = with power factor correction - Without lamp.

Diameter Weight Pack ProductType (mm) (kg) Qty. Code

C4SEL 773 3,70 1 31330

IP 54 reflector - diffuser

Suspension hook

Weight Pack ProductType Description (kg) Qty. Code

HOOKM With seal IP52 0,15 1 31232

Power supply boxMPM-3PF With seal IP52 0,33 1 31332

Safety chainAccessories

Weight Pack ProductType Description (kg) Qty. Code

SFC3-B For the body, of 0,9 m length 0,25 1 31273

Page 13: 81-105

GE Consumer & Industrial 92Lighting

Luminaire available in two versions, open and ventilated (OMG) or enclosedsuitable for use in damp environments (OMGC), both for discharge lamps upto 1000 W. Optical assembly available in two sizes: 14” and 18”.

Total reflection prisms.The light hits both surfaces of the prism at 45°, so that the ray is reflected.

APPLICATIONSParticularly suitable for commercial and industrial lighting applications with a mounting height over 4 meters.

Incident lightRayo incidente

Reflected lightRayo reflejado

OMG OMNIGLOW

Page 14: 81-105

GE Consumer & Industrial 93Lighting

TECHNICAL CHARACTERISTICS • características técnicas

Available in two sizes: AG5up to 1000 W and AP5 up to400 W. Die-cast aluminiumballast housing, with whitepolyester powder paint fi-nish applied electrostaticallyand cured at 180°C over ananti-corrosion layer.

• • •The socket holder, joined tothe ballast housing, enablesphotometric distribution tobe set in 8 different positionsusing an ordinary screwdri-ver. Porcelain E40 or E27lamp socket according tothe type of lamp used.

Easy installation using a 3/4”NPSC threaded hub, locatedin the housing and resistantto vibration.

Ballast housing • Caja de equipo

Borosilicate glass reflectorwith total reflection prismsin the outer part, available intwo sizes: small (model 14)for lamps up to 400 W andlarge (model 18) for lampsup to 1000 W.White spun aluminium coverconnecting the reflector tothe ballast housing. Theopen version has three rec-tangular windows, whereasthe closed version has agasket to adjust the positionof the ballast housing.

Reflector support frame,made of three steel rodsand a lower zinc plated ringsupporting the glass; therods hold the glass in positi-on, fixing the ring to the top reflector cap.

Tempered protection glass(closed version only) resis-tant to thermal and mecha-nical stress. Fixed in a metalring with gasket it is fittedwith a hinge and two latchesto guarantee easy removal.

EPDM or si l icon gasket ,according to the lamp wat-tage, between the reflectorand the metal parts.Optionally, lamps up to 400W can be supplied with alarge ballast housing AG5capable of supporting a ro-om temperature up to 65°C.For higher temperaturesplease request further information.

Optical assembly

A mm B mm C mm

OMG-14 588 350 608OMGC-14 609 350 629OMG-18 604 470 624OMGC-18 625 470 645

Net weight from approx. 14 to 24 Kg.

Class:Clase: I

IIPP 5522 IIPP 5544

IIPP 2200 IIPP 5544 IIPP 6655

Ballast housingStandard Optional

Optical assemblyOpened Standard enclosed Optional enclosed

MH/HAL 175W 1000WMetal Halide Lamps

HPS/SAP 70W 1000WHigh Pressure Sodium Lamps

MV/VM 250W 1000WMercury Vapor Lamps

OMG OMNIGLOW

Page 15: 81-105

GE Consumer & Industrial 94Lighting

1 Ballast housing AG5.2 Ballast housing AP5.3 3/4” NPSC threaded hub (*).4 Socket holder allowing the lamp tobe adjusted to 8 different positions.5 Lamp socket.6 Gasket between top cap and housing(OMGC version only).7 Aluminium reflector cap withwindows only in the opened versions(OMG).8 Borosilicate glass reflector.9 Three steel rods.10 Zinc plated steel support ring.11 Gaskets supporting glass reflector.12 Flat tempered glass door (OMGCversion only).

COMPONENTS

ORDERING INFORMATION

N O T E S

• Always use the large ballast housing (AG5) for 600 W to 1000 W lamps.• When using the large optical assembly (18) with lamps up to 400W, a narrower photometric distribution is achieved.• The MH 1000 W lamps used in the enclosed versions must be of reduced jacket BT 37 type. Optional IP65 (for optical assembly) andIP54 (for ballast housing) available for enclosed versions only.• For electronic emergency devices, fuses, suspension accessories (i.e., HOOKM), etc., please see pages 64-65. They must be orderedseparately.

OMG:Opened

OMGC:Enlosed

14: 350 mm(max 400 W)

18: 470 mm(max 1000W)

AP5:(max 400W)

AG5:(max 1000W)

MH175WMH250WMH400WMH1000WHPS70WHPS100WHPS150WHPS250WHPS400WHPS600WHPS750WHPS1000WMV250WMV400WMV1000W

208 V220 V230 V240 V277 V

50 Hz60 Hz

HPF:High power factor

E: Electronic emergency device

IP 65: Optical assembly IP 65(enclosed version)

IP 54: Ballast housing IP 54(enclosed version)

*R: Ballast reactor type

**S: Magnetic regulator

Luminaire Optical assembly Housing Lamp type Voltage Frequency Power factor Options

OMG 18C AP5 MH400W 220 V 50 Hz HPF R IP 65 IP 54

The standard ballasts are of the following types:MV250W up to 1000W ReactorHPS250W up to 600W ReactorHPS750W, 1000W CWAMH175W up to 1000W CWA

*The following types are also available on request:MH250W, 400W Reactor (Mercury type+Ignitor) **Only for Super High Output long life, MH400W lamp (uses AG5)

OMG OMNIGLOW

Page 16: 81-105

GE Consumer & Industrial 95Lighting

APPLICATIONSParticularly suitable for industrial and commercial lightingapplications; mounting height over 4 meters (medium-high).

The socket holder, joined tothe ballast housing, enableson-site adjustment of photo-metric distribution to 5 diffe-rent positions using an ordi-nary screwdriver. PorcelainE40 or E27 lamp socket ac-cording to the type of lampused.

TECHNICAL CHARACTERISTICS

Die-cast aluminium ballasthousing, with grey polyesterpowder paint finish appliedelectrostatically and curedat 180°C over an anti-corro-sion layer.

• • Easy installation using a 3/4”NPSC threaded hub, locatedin the housing and resistantto vibrations.

The optical assembly com-prises an injection moulded,UV stabilised acrylic reflec-tor with total reflection pri-sms, available in two sizes(diameter 413 mm for GHBP-16 and 571 mm for GHBP-22).

Net weight from approx. 9 to 16 Kg.

Optical assembly

IIPP 5522

IIPP 2200

Ballast housing

Class:Clase: I

MH/HAL 250W 400WMetal Halide Lamps

HPS/SAP 150W 400WHigh Pressure Sodium Lamps

MV/VM 250W 400WMercury Vapor Lamps

GHPB

Open and ventilated unit, for discharge lamps up to 250 W(GHBP-16) and up to 400 W (GHBP-22).

Page 17: 81-105

GE Consumer & Industrial 96Lighting

GHPBORDERING INFORMATION

NOTES

• In case a bottom enclosure is needed, contact factory.• For electronic emergency devices, fuses, suspension accesories (i.e., HOOKM), etc., They must be ordered separately.

PHOTOMETRIC DATA

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

GHBP-16; Lampholder position / 5; Lamps ST 250

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.490 0.560 0.670 0.730 0.790 0.820 0.8400.30 0.420 0.500 0.610 0.680 0.760 0.790 0.8100.10 0.370 0.450 0.570 0.650 0.730 0.760 0.790

0.50 0.50 0.10 0.460 0.530 0.630 0.690 0.750 0.780 0.7900.30 0.400 0.470 0.590 0.650 0.720 0.750 0.7700.10 0.360 0.430 0.550 0.620 0.700 0.730 0.750

0.30 0.50 0.10 0.440 0.500 0.600 0.660 0.710 0.740 0.7500.30 0.390 0.460 0.560 0.620 0.690 0.720 0.7300.10 0.350 0.420 0.530 0.600 0.670 0.700 0.720

0.70 0.70 0.30 0.630 0.710 0.820 0.880 0.950 0.980 1.0000.50 0.510 0.600 0.730 0.800 0.890 0.930 0.960

0.50 0.70 0.30 0.580 0.650 0.750 0.810 0.860 0.890 0.9000.70 0.10 0.540 0.600 0.690 0.740 0.780 0.800 0.820

SHR NOM 1.90

ULOR 0.133 DLOR 0.778 LOR 0.911

50 88 94 85 91CIE FLUX CODE

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

GHBP-22; Lampholder position / 3; Lamps QE/ME 400

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.510 0.570 0.650 0.700 0.760 0.790 0.8000.30 0.450 0.510 0.600 0.660 0.730 0.760 0.7800.10 0.410 0.470 0.570 0.630 0.700 0.740 0.760

0.50 0.50 0.10 0.480 0.540 0.620 0.660 0.720 0.740 0.7600.30 0.440 0.490 0.580 0.630 0.690 0.720 0.7400.10 0.400 0.450 0.540 0.600 0.670 0.700 0.720

0.30 0.50 0.10 0.460 0.510 0.580 0.630 0.670 0.700 0.7100.30 0.420 0.470 0.550 0.600 0.650 0.680 0.7000.10 0.390 0.440 0.520 0.570 0.630 0.660 0.680

0.70 0.70 0.30 0.640 0.700 0.800 0.850 0.910 0.940 0.9600.50 0.540 0.600 0.7100 0.780 0.850 0.890 0.920

0.50 0.70 0.30 0.590 0.640 0.720 0.770 0.820 0.850 0.8600.70 0.10 0.550 0.600 0.660 0.700 0.750 0.770 0.780

SHR NOM 1.50

ULOR 0.158 DLOR 0.720 LOR 0.878

62 85 92 82 88CIE FLUX CODE

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

GHBP-22; Lampholder position / 5; Lamps ST 400

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.550 0.600 0.680 0.740 0.790 0.810 0.8300.30 0.490 0.550 0.640 0.700 0.760 0.790 0.8100.10 0.460 0.520 0.610 0.670 0.740 0.770 0.790

0.50 0.50 0.10 0.530 0.580 0.660 0.700 0.750 0.780 0.7900.30 0.480 0.540 0.620 0.670 0.730 0.760 0.7700.10 0.450 0.500 0.590 0.650 0.710 0.740 0.760

0.30 0.50 0.10 0.510 0.560 0.630 0.670 0.720 0.740 0.7500.30 0.470 0.520 0.600 0.650 0.700 0.730 0.7400.10 0.440 0.490 0.570 0.630 0.690 0.710 0.730

0.70 0.70 0.30 0.680 0.740 0.830 0.880 0.940 0.960 0.9800.50 0.580 0.640 0.750 0.810 0.880 0.920 0.940

0.50 0.70 0.30 0.630 0.680 0.760 0.810 0.860 0.880 0.8900.70 0.10 0.590 0.630 0.700 0.740 0.780 0.800 0.810

SHR NOM 1.60

ULOR 0.106 DLOR 0.763 LOR 0.869

68 89 95 88 87CIE FLUX CODE

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

GHBP-16; Lampholder position / 4; Lamps ST 70/150

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.610 0.670 0.750 0.800 0.850 0.880 0.8900.30 0.560 0.620 0.710 0.770 0.830 0.860 0.8700.10 0.530 0.590 0.680 0.740 0.810 0.840 0.860

0.50 0.50 0.10 0.600 0.650 0.730 0.780 0.830 0.850 0.8600.30 0.560 0.610 0.700 0.750 0.810 0.830 0.8500.10 0.520 0.580 0.670 0.730 0.790 0.820 0.840

0.30 0.50 0.10 0.580 0.640 0.710 0.760 0.810 0.830 0.8400.30 0.550 0.600 0.680 0.740 0.790 0.810 0.8300.10 0.520 0.570 0.660 0.720 0.770 0.800 0.820

0.70 0.70 0.30 0.750 0.810 0.900 0.950 1.010 1.030 1.0500.50 0.650 0.720 0.820 0.890 0.960 0.990 1.010

0.50 0.70 0.30 0.710 0.760 0.840 0.890 0.940 0.960 0.9700.70 0.10 0.660 0.710 0.770 0.810 0.850 0.870 0.880

SHR NOM 1.50

ULOR 0.048 DLOR 0.850 LOR 0.898

74 93 97 95 90CIE FLUX CODE

GHBP 16: 413 mm (max 250 W)

22: 571 mm (max 400 W)

MH250WMH400WHPS70WHPS100WHPS150WHPS250WHPS400WMV250WMV400W

208 V220 V230 V240 V277 V

50 Hz60 Hz

HPF:High power factor

E: Electronic emergency device

*R: Ballast reactor type

Luminaire Optical assembly Lamp type Voltage Frequency Power factor

Options

GHBP 22 MH400W 220 V 50 Hz HPF

The standard ballasts are of the following types:MV250W, 400W ReactorHPS70W up to 400W ReactorMH250W, 400W CWA

*The following types are also available on request:MH250W, 400W Reactor (Mercury type+Ignitor)

Dimensions in mm

Page 18: 81-105

GE Consumer & Industrial 97Lighting

OMBS OMNIBEAM

TECHNICAL CHARACTERISTICS

Die-cast aluminium ballasthousing, with white polyes-ter powder paint finish appli-ed electrostatically and cu-red at 180°C over an anti-corrosion layer.

Easy installation using a 3/4”NPSC threaded hub, locatedin the housing and resistantto vibrations.

Eight-position mountingbracket , allowing differentlight distributions. PorcelainE40 lamp socket.

UV stabilized acrylic prisma-tic reflector.

IP 52

IP 20

Ballast housing

Optical assembly

Net weight from approx. 14 to 21 Kg.

Class: I

MH/HAL 250W 400WMetal Halide Lamps

HPS/SAP 250W 400WHigh Pressure Sodium Lamps

MV/VM 250W 400WMercury Vapor Lamps

APPLICATIONSSuitable for the lighting of commercial areas, as well as applicationssuch as assembly lines, inspection areas, production bays, storageareas, hangars and railway stations, with mounting height over 5 meters.

Luminaire with an open and ventilated acrylic reflector, fordischarge lamps up to 400 W. The unit can be supplied enclosedunder request.

Page 19: 81-105

GE Consumer & Industrial 98Lighting

OMG OMNIBEAM

ORDERING INFORMATION

OMBS MH250WMH400WHPS250WHPS400WMV250WMV400W

208 V220 V230 V240 V277 V

50 Hz60 Hz

HPF:High power factor

E: Electronic emergency device

*R: Ballast reactor type

Luminaire Lamp type Voltage Frequency Power factor Options

OMBS MH400W 220V 50Hz HPF

The standard ballasts are of the following types:MV250W, 400W ReactorHPS250W, 400W ReactorMH250W, 400W CWA

* The following types are also available on request:MH250W, 400W Reactor (Mercury type+Ignitor)

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

OMBS; Lampholder position G; Lamps ST 250/400

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.70 0.30 0.700 0.770 0.890 0.950 1.020 1.050 1.0700.50 0.30 0.580 0.660 0.790 0.870 0.950 0.990 1.020

0.10 0.550 0.620 0.730 0.790 0.850 0.880 0.8900.30 0.10 0.490 0.560 0.670 0.740 0.810 0.850 0.870

0.50 0.50 0.30 0.560 0.630 0.750 0.820 0.890 0.920 0.9400.10 0.530 0.600 0.700 0.760 0.820 0.840 0.860

0.30 0.30 0.490 0.570 0.690 0.760 0.850 0.890 0.9100.10 0.480 0.550 0.650 0.720 0.790 0.820 0.840

0.30 0.30 0.10 0.460 0.530 0.630 0.700 0.760 0.790 0.8100.10 0.10 0.430 0.490 0.600 0.670 0.740 0.770 0.790

0.00 0.00 0.00 0.400 0.470 0.570 0.640 0.700 0.730 0.750

SHR NOM 1.7

ULOR 0.080 DLOR 0.866 LOR 0.947

57 88 94 92 95CIE FLUX CODE

PHOTOMETRIC DATA

Page 20: 81-105

GE Consumer & Industrial 99Lighting

HIPER

APPLICATIONSParticularly suitable for large areas as supermarkets and shopping malls;mounting height over 4 meters.

TECHNICAL CHARACTERISTICS

Open and ventilated luminaire with flat glass door on request.

Housing in heavy duty steelplate, with polyester powderpaint finish appliedelectrostatically and curedat 180°C over an anti-corrosion layer.

Aluminium faceted reflector.The faceted design reducesand controls the glare of thelamp.

E40 porcelain lamp socket.

IP 20

Net weight from approx. 15 to 18 Kg.

Class: I

Dimensions in mm

MH 250W 400WMetal Halide Lamps

HPS 250W 400WHigh Pressure Sodium Lamps

MV 400WMercury Vapor Lamps

Compact luminaire for discharge lamps up to 400 W with open, ventila-ted optical assembly (can be enclosed on request) which guaranteesextremely effective, low glare lighting thanks to its faceted reflector.

Page 21: 81-105

GE Consumer & Industrial 100Lighting

HIPER

ORDERING INFORMATION

PHOTOMETRIC DATA

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

HIPER; Lampholder position: FIXED; Lamps QE 400 - ME 250/400

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.480 0.540 0.630 0.680 0.730 0.750 0.7600.30 0.430 0.500 0.590 0.650 0.710 0.730 0.7400.10 0.390 0.460 0.570 0.630 0.690 0.720 0.730

0.50 0.50 0.10 0.470 0.530 0.620 0.670 0.710 0.730 0.7400.30 0.430 0.490 0.590 0.640 0.700 0.720 0.7300.10 0.390 0.460 0.560 0.620 0.680 0.710 0.720

0.30 0.50 0.10 0.460 0.520 0.610 0.660 0.700 0.720 0.7300.30 0.420 0.480 0.580 0.630 0.690 0.710 0.7200.10 0.390 0.460 0.560 0.620 0.670 0.700 0.710

0.70 0.70 0.30 0.600 0.660 0.760 0.810 0.860 0.880 0.9000.50 0.510 0.580 0.690 0.750 0.820 0.850 0.870

0.50 0.70 0.30 0.570 0.630 0.720 0.760 0.810 0.830 0.8400.70 0.10 0.530 0.580 0.660 0.700 0.740 0.750 0.760

SHR NOM 1.90

ULOR 0.000 DLOR 0.758 LOR 0.758

62 97 100 100 76CIE FLUX CODE

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

HIPER; Lampholder position / FIXED; Lamps ST 250/400

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.540 0.610 0.700 0.750 0.800 0.820 0.8300.30 0.500 0.560 0.670 0.730 0.780 0.800 0.8200.10 0.460 0.530 0.640 0.700 0.760 0.790 0.800

0.50 0.50 0.10 0.540 0.600 0.690 0.740 0.790 0.810 0.8200.30 0.490 0.560 0.660 0.720 0.770 0.790 0.8000.10 0.460 0.530 0.630 0.690 0.750 0.780 0.790

0.30 0.50 0.10 0.530 0.590 0.680 0.730 0.770 0.790 0.8000.30 0.490 0.550 0.650 0.710 0.760 0.780 0.7900.10 0.460 0.520 0.630 0.690 0.750 0.770 0.780

0.70 0.70 0.30 0.670 0.740 0.840 0.890 0.940 0.970 0.9800.50 0.580 0.650 0.770 0.830 0.900 0.930 0.950

0.50 0.70 0.30 0.640 0.700 0.790 0.840 0.890 0.910 0.9200.70 0.10 0.600 0.650 0.730 0.770 0.810 0.820 0.830

SHR NOM 1.40

ULOR 0.000 DLOR 0.823 LOR 0.823

67 99 100 100 82CIE FLUX CODE

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

HIPER; Lampholder position / FIXED; Lamps MC 250/400

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.500 0.560 0.660 0.720 0.760 0.780 0.7900.30 0.440 0.520 0.620 0.690 0.740 0.770 0.7800.10 0.410 0.480 0.590 0.660 0.720 0.750 0.760

0.50 0.50 0.10 0.490 0.550 0.650 0.700 0.750 0.770 0.7800.30 0.440 0.510 0.620 0.680 0.730 0.750 0.7600.10 0.400 0.480 0.590 0.650 0.710 0.740 0.750

0.30 0.50 0.10 0.480 0.540 0.640 0.690 0.740 0.750 0.7600.30 0.430 0.500 0.610 0.670 0.720 0.740 0.7500.10 0.400 0.470 0.580 0.650 0.700 0.730 0.740

0.70 0.70 0.30 0.620 0.690 0.790 0.850 0.900 0.930 0.9400.50 0.520 0.600 0.720 0.790 0.860 0.890 0.910

0.50 0.70 0.30 0.590 0.660 0.750 0.800 0.850 0.870 0.8800.70 0.10 0.550 0.610 0.690 0.730 0.770 0.790 0.790

SHR NOM 1.60

ULOR 0.000 DLOR 0.796 LOR 0.796

60 99 100 100 80CIE FLUX CODE

HIPER MH250WMH400WHPS250WHPS400WMV400W

208 V220 V230 V240 V277 V

50 Hz60 Hz

HPF:High power factor

E: Electronic emergency device

V: With glass door enclosure

*R: Ballast reactor type

**S: Magnetic regulator

Luminaire Lamp type Voltage Frequency Power factor Options

HIPER MH250W 220 V 50 Hz HPF E

The standard ballasts are of the following types:MV400W ReactorHPS250W, 400W ReactorMH250W, 400W CWA

*The following types are also available on request:MH250W, 400W Reactor (Mercury type+Ignitor) **Only for Super High Output, long life, MH400W lamp

Page 22: 81-105

GE Consumer & Industrial 101Lighting

VSG VERSAGLOW

APPLICATIONSSuitable for the lighting of classrooms, offices, cafeterias and commercialareas, with mounting heights between 2.2 and 7 meters.

TECHNICAL CHARACTERISTICS

Die-cast aluminium ballasthousing, with grey polyesterpowder paint finish appliedelectrostatically and curedat 180°C over an anti-corrosion layer.

Sliding disconnect, guarantees safe and easyelectrical and mechanicalassembling with the optical.Please request informationon the possibility of installation using a 3/4”threaded hub.

Porcelain E40 or E27 lampsocket, according to thelamp used.

UV stabilised acrylic prismatic refractor (inLEXAN®1 polycarbonate onrequest) offering high visualcomfort thanks to uniformlight distribution over thewhole surface.

IP 42

ØB Net weight from approx. 10 to 16Kg.

Class: I

MH 70W 250WMetal Halide Lamps

HPS 70W 250WHigh Pressure Sodium Lamps

MV 125W 250WMercury Vapor Lamps

A mm ØB mm

VSG-150 311 567

VSG-250 352 768

Enclosed luminaires suitable for damp environments, for discharge lamps upto 250 W (VSG-250) or up to 150 W (VSG-150). The prismatic refractor provides high level of visual comfort in installations with direct-indirect lighting.

Page 23: 81-105

GE Consumer & Industrial 102Lighting

VSG VERSAGLOW

ORDERING INFORMATION

NOTES• For electronic emergency devices, fuses, suspension accesories, etc. must be ordered separately.

The standard ballasts are of the following types:MV125W, 250W ReactorHPS70W up to 250W ReactorMH70W up to 150W Reactor (HPS ballast+Ignitor)MH175W, 250W CWA

* The following type is also available on request:MH250W Reactor (Mercury type+Ignitor)

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

VSG-150; Lampholder position: Fixed; Lamps ST 70/150

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEX Ceiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.70 0.30 0.480 0.530 0.630 0.690 0.750 0.790 0.8100.50 0.30 0.370 0.430 0.540 0.610 0.690 0.740 0.760

0.10 0.350 0.400 0.490 0.550 0.610 0.650 0.6700.30 0.10 0.290 0.340 0.440 0.500 0.570 0.620 0.640

0.50 0.50 0.30 0.330 0.380 0.470 0.530 0.600 0.640 0.6600.10 0.310 0.360 0.440 0.490 0.550 0.580 0.600

0.30 0.30 0.270 0.320 0.410 0.480 0.560 0.600 0.6300.10 0.260 0.310 0.390 0.450 0.520 0.560 0.580

0.30 0.30 0.10 0.230 0.280 0.350 0.410 0.470 0.500 0.5200.10 0.10 0.200 0.240 0.320 0.380 0.440 0.480 0.510

0.00 0.00 0.00 0.160 0.200 0.260 0.310 0.370 0.400 0.420

SHR NOM 1.5

ULOR 0.265 DLOR 0.539 LOR 0.804

35 66 88 67 80CIE FLUX CODE

POLAR DIAGRAM NORMAL EFFICIENCY

UTILISATION FACTOR - UF (Floor)

CIE FLUX CODE

SPACING HEIGHT RATIO

VSG-250; Lampholder position: Fixed; Lamps ST 250

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.80 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.70 0.30 0.480 0.540 0.640 0.700 0.760 0.800 0.8200.50 0.30 0.370 0.440 0.540 0.610 0.700 0.750 0.780

0.10 0.350 0.410 0.500 0.560 0.620 0.660 0.6800.30 0.10 0.290 0.340 0.440 0.510 0.580 0.620 0.650

0.50 0.50 0.30 0.330 0.380 0.470 0.530 0.600 0.640 0.6700.10 0.310 0.360 0.440 0.490 0.550 0.590 0.610

0.30 0.30 0.270 0.320 0.410 0.480 0.560 0.600 0.6300.10 0.260 0.310 0.390 0.450 0.520 0.560 0.580

0.30 0.30 0.10 0.230 0.270 0.350 0.400 0.460 0.500 0.5200.10 0.10 0.200 0.240 0.320 0.370 0.440 0.480 0.500

0.00 0.00 0.00 0.150 0.190 0.250 0.300 0.350 0.390 0.410

SHR NOM 1.6

ULOR 0.304 DLOR 0.525 LOR 0.828

34 65 87 63 83CIE FLUX CODE

PHOTOMETRIC DATA

VSG-150VSG-250

P: Polycarbonate LEXAN

MH70WMH100WMH150WMH175WMH250WHPS70WHPS100WHPS150WHPS250WMV125WMV250W

208 V220 V230 V240 V277 V

50 Hz60 Hz

HPF:High power factor

E: Electronic emergency device

*R: Ballast reactor type

Luminaire Optional refractor Lamp type Voltage Frequency Power factor Options

VSG-150 MH100W 220 V 50 Hz HPF

Page 24: 81-105

GE Consumer & Industrial 103Lighting

GGD GARAGE GARD

Lamp Weight Pack Qty ProductType Type (Kg) Box Code

GGD15SA LU150/T/40 7,00 1 17274

GGD15HAL MH150 7,00 1 17275

GGD Class: I IP 20 230V 50Hz IEC - CEI

Luminaire, suitable for use in damp environments 70-100-150W high pressure sodium and metal halide lamps. The special distribution of light throu-gh the prismatic refractor, enables it to be used in area with reduced mountingheights giving excellent illumination on vertical surfaces.Applications Particularly suitable for underground car parks and garages for warehouses,service stations, stairways, working areas and task lighting. Mounting highabove 2.2 meter.Key Features• Body, in die cast aluminium with grey polyester powder paint finish, appliedelectrostaticaly and cured at 180 (C, over an anti-corrotion layer.• Easy installation through a ceiling mounting plate • Ballast housing fitted with an oven-cured white aluminium reflector.

Page 25: 81-105

GE Consumer & Industrial 104Lighting

Photometric data

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

§SPACING – HEIGHT RATIO

CPC 400

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.379 0.472 0.511 0.536 0.561 0.574 0.5820.30 0.346 0.447 0.490 0.518 0.547 0.562 0.5720.10 0.322 0.428 0.473 0.503 0.535 0.552 0.563

0.50 0.50 0.10 0.372 0.465 0.503 0.527 0.550 0.562 0.5700.30 0.343 0.443 0.485 0.512 0.538 0.553 0.5620.10 0.321 0.427 0.470 0.498 0.528 0.544 0.555

0.30 0.50 0.10 0.367 0.459 0.495 0.518 0.541 0.552 0.5590.30 0.340 0.440 0.479 0.505 0.531 0.544 0.5530.10 0.319 0.424 0.466 0.494 0.522 0.537 0.546

0.70 0.50 0.20 0.389 0.487 0.533 0.563 0.593 0.609 0.6200.30 0.352 0.458 0.506 0.539 0.574 0.594 0.6070.10 0.325 0.435 0.485 0.520 0.558 0.580 0.595

0.50 0.50 0.20 0.381 0.477 0.519 0.546 0.573 0.588 0.5970.30 0.347 0.451 0.497 0.527 0.558 0.575 0.5860.10 0.323 0.432 0.478 0.510 0.544 0.564 0.576

SHR NOM 2.00 SHR MAX 2.03 SHR MAX TR 2.27

ULOR 0.000 DLOR 0.573 LOR 0.573

CIE FLUX CODE 57 91 98 100 57

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°

90.0° 270.0°

Semipiani C

180150135120

0

225

150

75

300

1530

60

75

90

105

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

CPC 400 + CPG

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.315 0.353 0.402 0.428 0.456 0.470 0.4790.30 0.287 0.326 0.380 0.409 0.440 0.457 0.4680.10 0.266 0.306 0.362 0.393 0.427 0.446 0.459

0.50 0.50 0.10 0.309 0.347 0.395 0.420 0.446 0.460 0.4680.30 0.284 0.323 0.375 0.403 0.433 0.449 0.4600.10 0.265 0.304 0.359 0.389 0.422 0.440 0.452

0.30 0.50 0.10 0.305 0.341 0.387 0.412 0.437 0.451 0.4590.30 0.282 0.319 0.370 0.397 0.426 0.442 0.4520.10 0.264 0.303 0.356 0.385 0.417 0.434 0.445

0.70 0.50 0.20 0.323 0.365 0.420 0.449 0.482 0.499 0.5100.30 0.292 0.334 0.393 0.425 0.462 0.483 0.4970.10 0.269 0.311 0.371 0.406 0.446 0.469 0.484

0.50 0.50 0.20 0.316 0.356 0.408 0.435 0.464 0.480 0.4900.30 0.288 0.329 0.384 0.415 0.449 0.467 0.4790.10 0.267 0.308 0.365 0.398 0.435 0.456 0.469

SHR NOM 2.00 SHR MAX 2.02 SHR MAX TR 2.27

ULOR 0.000 DLOR 0.480 LOR 0.480

CIE FLUX CODE 94 99 99 100 78

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°

90.0° 270.0°

Semipiani C

180150135120

0

150

100

50

200

1530

60

75

90

105

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

CPC 400 + CPL

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.283 0.310 0.346 0.365 0.386 0.397 0.4040.30 0.262 0.290 0.329 0.350 0.374 0.387 0.3960.10 0.247 0.274 0.315 0.338 0.364 0.379 0.388

0.50 0.50 0.10 0.279 0.305 0.340 0.358 0.378 0.388 0.3950.30 0.260 0.287 0.325 0.346 0.368 0.381 0.3890.10 0.246 0.273 0.313 0.335 0.360 0.373 0.382

0.30 0.50 0.10 0.275 0.300 0.334 0.352 0.371 0.381 0.3880.30 0.258 0.284 0.321 0.341 0.363 0.374 0.3820.10 0.245 0.272 0.310 0.331 0.355 0.368 0.377

0.70 0.50 0.20 0.291 0.320 0.361 0.383 0.408 0.421 0.4300.30 0.267 0.297 0.340 0.365 0.393 0.409 0.4200.10 0.250 0.279 0.323 0.349 0.380 0.398 0.410

0.50 0.50 0.20 0.285 0.313 0.351 0.371 0.394 0.406 0.4140.30 0.264 0.292 0.333 0.356 0.381 0.396 0.4050.10 0.248 0.276 0.318 0.342 0.371 0.387 0.397

SHR NOM 1.50 SHR MAX 1.67 SHR MAX TR 1.86

ULOR 0.000 DLOR 0.402 LOR 0.402

CIE FLUX CODE 62 89 97 100 40

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°

90.0° 270.0°

Semipiani C

180150135120

0

150

100

50

200

1530

60

75

90

105

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

CPC 250M

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.514 0.561 0.590 0.619 0.634 0.6430.30 0.486 0.537 0.570 0.603 0.621 0.6320.10 0.464 0.517 0.552 0.589 0.609 0.622

0.50 0.50 0.10 0.506 0.552 0.580 0.607 0.621 0.6300.30 0.482 0.530 0.562 0.593 0.611 0.6210.10 0.462 0.513 0.547 0.582 0.601 0.613

0.30 0.50 0.10 0.499 0.543 0.570 0.596 0.610 0.6190.30 0.477 0.524 0.555 0.585 0.601 0.6110.10 0.459 0.509 0.542 0.575 0.593 0.603

0.70 0.50 0.20 0.531 0.585 0.619 0.655 0.674 0.6860.30 0.497 0.554 0.593 0.633 0.656 0.6700.10 0.471 0.530 0.570 0.614 0.640 0.657

0.50 0.50 0.20 0.520 0.570 0.601 0.633 0.649 0.6600.30 0.490 0.543 0.579 0.615 0.635 0.6470.10 0.467 0.522 0.560 0.599 0.622 0.636

SHR NOM 2.00 SHR MAX 2.10 SHR MAX TR 2.31

ULOR 0.000 DLOR 0.635 LOR 0.635

CIE FLUX CODE 55 91 98 100 63

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°

90.0° 270.0°

Semipiani C

180150135120

0

225

150

75

300

1530

60

75

90

105

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

EB250M1

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.679 0.731 0.759 0.787 0.801 0.8090.30 0.651 0.708 0.739 0.772 0.789 0.7990.10 0.629 0.690 0.723 0.759 0.778 0.790

0.50 0.50 0.10 0.671 0.722 0.747 0.773 0.786 0.7940.30 0.646 0.701 0.731 0.761 0.777 0.7860.10 0.627 0.685 0.716 0.750 0.768 0.779

0.30 0.50 0.10 0.663 0.711 0.736 0.761 0.773 0.7800.30 0.641 0.694 0.722 0.751 0.765 0.7740.10 0.624 0.680 0.709 0.741 0.758 0.767

0.70 0.50 0.20 0.702 0.763 0.796 0.833 0.851 0.8630.30 0.666 0.732 0.769 0.810 0.833 0.8480.10 0.639 0.708 0.747 0.792 0.818 0.834

0.50 0.50 0.20 0.688 0.745 0.774 0.805 0.822 0.8310.30 0.658 0.718 0.752 0.788 0.807 0.8190.10 0.634 0.697 0.733 0.773 0.795 0.809

SHR NOM 0.75 SHR MAX 0.93

ULOR 0.000 DLOR 0.785 LOR 0.785

CIE FLUX CODE 94 99 99 100 78

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

180150135120

0

600

400

200

800

1530

60

75

90

105

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

EB250M4

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.588 0.675 0.720 0.766 0.789 0.8040.30 0.543 0.638 0.690 0.743 0.771 0.7880.10 0.509 0.609 0.664 0.723 0.754 0.774

0.50 0.50 0.10 0.577 0.662 0.706 0.751 0.773 0.7870.30 0.538 0.630 0.680 0.731 0.758 0.7750.10 0.507 0.604 0.657 0.714 0.744 0.762

0.30 0.50 0.10 0.567 0.650 0.693 0.737 0.758 0.7720.30 0.532 0.622 0.671 0.720 0.746 0.7610.10 0.504 0.599 0.651 0.705 0.734 0.751

0.70 0.50 0.20 0.607 0.704 0.756 0.811 0.839 0.8560.30 0.556 0.659 0.717 0.780 0.814 0.8360.10 0.517 0.625 0.686 0.754 0.792 0.817

0.50 0.50 0.20 0.592 0.683 0.732 0.782 0.808 0.8240.30 0.547 0.646 0.700 0.757 0.788 0.8070.10 0.512 0.615 0.673 0.736 0.770 0.792

SHR NOM 0.50 SHR MAX 0.73

ULOR 0.000 DLOR 0.799 LOR 0.799

CIE FLUX CODE 72 98 99 100 79

180150135120

0

300

200

100

400

1530

60

75

90

105

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

EB400M1

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.664 0.735 0.772 0.810 0.829 0.8410.30 0.627 0.705 0.747 0.791 0.814 0.8280.10 0.599 0.681 0.726 0.774 0.800 0.816

0.50 0.50 0.10 0.654 0.724 0.759 0.795 0.813 0.8240.30 0.622 0.697 0.738 0.779 0.800 0.8140.10 0.596 0.676 0.719 0.765 0.789 0.804

0.30 0.50 0.10 0.645 0.712 0.747 0.781 0.799 0.8090.30 0.616 0.689 0.728 0.768 0.788 0.8000.10 0.593 0.670 0.712 0.755 0.778 0.792

0.70 0.50 0.20 0.686 0.767 0.811 0.857 0.881 0.8960.30 0.642 0.728 0.777 0.830 0.859 0.8780.10 0.608 0.698 0.750 0.808 0.840 0.861

0.50 0.50 0.20 0.672 0.747 0.787 0.828 0.850 0.8630.30 0.633 0.714 0.759 0.807 0.832 0.8480.10 0.603 0.687 0.735 0.788 0.817 0.835

SHR NOM 1.00 SHR MAX 1.25

ULOR 0.000 DLOR 0.825 LOR 0.825

CIE FLUX CODE 79 98 99 100 82

180150135120

0

375

250

125

500

1530

60

75

90

105

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

EB400M4

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.612 0.700 0.746 0.792 0.814 0.8280.30 0.568 0.665 0.717 0.769 0.796 0.8130.10 0.534 0.636 0.691 0.749 0.780 0.799

0.50 0.50 0.10 0.601 0.688 0.732 0.776 0.798 0.8110.30 0.562 0.656 0.707 0.756 0.783 0.7990.10 0.531 0.630 0.685 0.740 0.769 0.787

0.30 0.50 0.10 0.591 0.675 0.719 0.761 0.783 0.7960.30 0.556 0.648 0.697 0.745 0.770 0.7850.10 0.528 0.625 0.678 0.730 0.759 0.775

0.70 0.50 0.20 0.633 0.731 0.783 0.837 0.865 0.8830.30 0.581 0.686 0.746 0.807 0.841 0.8620.10 0.542 0.652 0.714 0.781 0.819 0.843

0.50 0.50 0.20 0.617 0.710 0.759 0.808 0.834 0.8490.30 0.572 0.672 0.728 0.783 0.814 0.8320.10 0.537 0.642 0.701 0.762 0.796 0.817

SHR NOM 1.75 SHR MAX 1.81

ULOR 0.000 DLOR 0.821 LOR 0.821

CIE FLUX CODE 48 95 99 100 82

180150135120

0

225

150

75

300

1530

60

75

90

105

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

Page 26: 81-105

GE Consumer & Industrial 105Lighting

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

EB400H1

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.564 0.636 0.674 0.713 0.733 0.7450.30 0.526 0.606 0.648 0.693 0.717 0.7320.10 0.497 0.581 0.626 0.676 0.703 0.719

0.50 0.50 0.10 0.554 0.626 0.662 0.699 0.718 0.7300.30 0.520 0.598 0.639 0.682 0.705 0.7190.10 0.494 0.576 0.620 0.668 0.693 0.709

0.30 0.50 0.10 0.545 0.614 0.650 0.686 0.705 0.7160.30 0.515 0.591 0.631 0.672 0.694 0.7070.10 0.491 0.571 0.614 0.659 0.684 0.698

0.70 0.50 0.20 0.582 0.664 0.707 0.755 0.779 0.7940.30 0.538 0.625 0.674 0.728 0.757 0.7760.10 0.504 0.596 0.647 0.705 0.738 0.760

0.50 0.50 0.20 0.568 0.646 0.686 0.728 0.750 0.7640.30 0.530 0.613 0.658 0.707 0.733 0.7490.10 0.500 0.586 0.634 0.688 0.718 0.736

SHR NOM 1.25 SHR MAX 1.36

ULOR 0.000 DLOR 0.737 LOR 0.737

CIE FLUX CODE 65 96 99 100 73

180150135120

0

300

200

100

400

1530

60

75

90

105

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

EB400H4

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.537 0.625 0.672 0.719 0.744 0.7590.30 0.491 0.587 0.640 0.695 0.724 0.7420.10 0.455 0.556 0.613 0.674 0.707 0.727

0.50 0.50 0.10 0.526 0.612 0.658 0.704 0.728 0.7420.30 0.485 0.579 0.631 0.683 0.712 0.7290.10 0.453 0.552 0.607 0.665 0.697 0.716

0.30 0.50 0.10 0.516 0.600 0.645 0.690 0.714 0.7280.30 0.479 0.571 0.622 0.673 0.700 0.7160.10 0.450 0.547 0.601 0.657 0.688 0.705

0.70 0.50 0.20 0.554 0.652 0.705 0.761 0.790 0.8090.30 0.502 0.606 0.666 0.730 0.765 0.7870.10 0.463 0.570 0.634 0.703 0.743 0.768

0.50 0.50 0.20 0.540 0.632 0.682 0.733 0.761 0.7770.30 0.493 0.593 0.649 0.708 0.740 0.7590.10 0.458 0.561 0.621 0.685 0.722 0.744

SHR NOM 1.75 SHR MAX 1.84

ULOR 0.000 DLOR 0.761 LOR 0.761

CIE FLUX CODE 46 88 99 100 76

180150135120

0

150

100

50

200

1530

60

75

90

105

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

EB400S1

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.664 0.735 0.772 0.810 0.829 0.8410.30 0.627 0.705 0.747 0.791 0.814 0.8280.10 0.599 0.681 0.726 0.774 0.800 0.816

0.50 0.50 0.10 0.654 0.724 0.759 0.795 0.813 0.8240.30 0.622 0.697 0.738 0.779 0.800 0.8140.10 0.596 0.676 0.719 0.765 0.789 0.804

0.30 0.50 0.10 0.645 0.712 0.747 0.781 0.799 0.8090.30 0.616 0.689 0.728 0.768 0.788 0.8000.10 0.593 0.670 0.712 0.755 0.778 0.792

0.70 0.50 0.20 0.686 0.767 0.811 0.857 0.881 0.8960.30 0.642 0.728 0.777 0.830 0.859 0.8780.10 0.608 0.698 0.750 0.808 0.840 0.861

0.50 0.50 0.20 0.672 0.747 0.787 0.828 0.850 0.8630.30 0.633 0.714 0.759 0.807 0.832 0.8480.10 0.603 0.687 0.735 0.788 0.817 0.835

SHR NOM 1.00 SHR MAX 1.25

ULOR 0.000 DLOR 0.825 LOR 0.825

CIE FLUX CODE 79 98 99 100 82

180150135120

0

375

250

125

500

1530

60

75

90

105

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

EB400S4

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.612 0.700 0.746 0.792 0.814 0.8280.30 0.568 0.665 0.717 0.769 0.796 0.8130.10 0.534 0.636 0.691 0.749 0.780 0.799

0.50 0.50 0.10 0.601 0.688 0.732 0.776 0.798 0.8110.30 0.562 0.656 0.707 0.756 0.783 0.7990.10 0.531 0.630 0.685 0.740 0.769 0.787

0.30 0.50 0.10 0.591 0.675 0.719 0.761 0.783 0.7960.30 0.556 0.648 0.697 0.745 0.770 0.7850.10 0.528 0.625 0.678 0.730 0.759 0.775

0.70 0.50 0.20 0.633 0.731 0.783 0.837 0.865 0.8830.30 0.581 0.686 0.746 0.807 0.841 0.8620.10 0.542 0.652 0.714 0.781 0.819 0.843

0.50 0.50 0.20 0.617 0.710 0.759 0.808 0.834 0.8490.30 0.572 0.672 0.728 0.783 0.814 0.8320.10 0.537 0.642 0.701 0.762 0.796 0.817

SHR NOM 1.75 SHR MAX 1.81

ULOR 0.000 DLOR 0.821 LOR 0.821

CIE FLUX CODE 48 95 99 100 82

180150135120

0

225

150

75

300

1530

60

75

90

105

cd/klm

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

FGS40S P3

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.497 0.566 0.636 0.671 0.708 0.726 0.7370.30 0.457 0.531 0.607 0.647 0.689 0.711 0.7250.10 0.428 0.503 0.584 0.627 0.673 0.698 0.713

0.50 0.50 0.10 0.489 0.557 0.626 0.659 0.694 0.712 0.7220.30 0.453 0.525 0.600 0.639 0.678 0.700 0.7120.10 0.427 0.501 0.580 0.621 0.665 0.688 0.703

0.30 0.50 0.10 0.482 0.549 0.615 0.648 0.682 0.699 0.7090.30 0.450 0.520 0.593 0.630 0.669 0.689 0.7000.10 0.425 0.498 0.575 0.615 0.657 0.679 0.692

0.70 0.50 0.20 0.510 0.585 0.664 0.704 0.749 0.771 0.7850.30 0.465 0.543 0.627 0.673 0.724 0.751 0.7690.10 0.432 0.511 0.599 0.647 0.703 0.733 0.753

0.50 0.50 0.20 0.500 0.572 0.646 0.683 0.723 0.744 0.7560.30 0.459 0.535 0.615 0.657 0.703 0.727 0.7420.10 0.430 0.507 0.590 0.635 0.685 0.713 0.730

SHR NOM 1.25 SHR MAX 1.47

ULOR 0.000 DLOR 0.726 LOR 0.726

CIE FLUX CODE 69 98 99 100 72

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

180150135120

0

300

200

100

400

1530

60

75

90

105

cd/klm

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

L4MD40S

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.358 0.420 0.511 0.560 0.614 0.642 0.6600.30 0.305 0.368 0.466 0.521 0.583 0.617 0.6390.10 0.267 0.328 0.430 0.488 0.556 0.594 0.619

0.50 0.50 0.10 0.348 0.408 0.498 0.545 0.598 0.626 0.6440.30 0.301 0.362 0.458 0.512 0.572 0.605 0.6270.10 0.265 0.326 0.426 0.482 0.548 0.585 0.609

0.30 0.50 0.10 0.340 0.398 0.485 0.532 0.584 0.612 0.6300.30 0.297 0.356 0.450 0.503 0.561 0.594 0.6140.10 0.264 0.324 0.422 0.477 0.541 0.577 0.600

0.70 0.50 0.20 0.367 0.434 0.533 0.587 0.649 0.682 0.7040.30 0.310 0.376 0.481 0.542 0.612 0.651 0.6780.10 0.269 0.333 0.441 0.504 0.580 0.624 0.654

0.50 0.50 0.20 0.356 0.419 0.513 0.565 0.623 0.654 0.6750.30 0.305 0.368 0.469 0.527 0.592 0.629 0.6530.10 0.267 0.330 0.434 0.494 0.565 0.606 0.633

SHR NOM 2.00 SHR MAX 2.06

ULOR 0.000 DLOR 0.689 LOR 0.689

CIE FLUX CODE 38 77 94 100 68

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

180150135120

0

120

80

40

160

1530

60

75

90

105

cd/klm

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

C4S40S

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.376 0.446 0.550 0.606 0.667 0.699 0.7190.30 0.317 0.388 0.501 0.563 0.634 0.672 0.6960.10 0.274 0.343 0.461 0.528 0.604 0.647 0.675

0.50 0.50 0.10 0.365 0.434 0.536 0.591 0.651 0.682 0.7020.30 0.312 0.382 0.493 0.554 0.621 0.659 0.6830.10 0.272 0.341 0.457 0.522 0.596 0.638 0.665

0.30 0.50 0.10 0.356 0.422 0.522 0.576 0.635 0.666 0.6860.30 0.307 0.375 0.484 0.544 0.610 0.647 0.6700.10 0.271 0.339 0.452 0.516 0.588 0.629 0.654

0.70 0.50 0.20 0.386 0.461 0.574 0.636 0.706 0.743 0.7670.30 0.322 0.397 0.517 0.586 0.665 0.709 0.7390.10 0.276 0.349 0.473 0.545 0.631 0.680 0.713

0.50 0.50 0.20 0.373 0.445 0.553 0.612 0.677 0.713 0.7350.30 0.316 0.388 0.505 0.570 0.644 0.685 0.7110.10 0.274 0.345 0.465 0.534 0.614 0.660 0.690

SHR NOM 2.25 SHR MAX 2.38

ULOR 0.000 DLOR 0.750 LOR 0.750

CIE FLUX CODE 36 77 95 100 75

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

180150135120

0

120

80

40

160

1530

60

75

90

105

cd/klm

POLAR DIAGRAMOF OUTPUT

NORMAL EFFICIENCY

UTILISATION FACTOR – UF (Floor)

CIE FLUX CODE

SPACING – HEIGHT RATIO

VBSD40S

(cd/1000 lm)

REFLECTION FACTOR ROOM INDEXCeiling Walls Floor 0.75 1.00 1.50 2.00 3.00 4.00 5.00

0.70 0.50 0.10 0.512 0.580 0.673 0.721 0.774 0.801 0.8180.30 0.459 0.528 0.629 0.683 0.743 0.776 0.7970.10 0.420 0.489 0.593 0.651 0.717 0.753 0.777

0.50 0.50 0.10 0.502 0.568 0.659 0.706 0.756 0.783 0.8000.30 0.454 0.522 0.620 0.673 0.730 0.762 0.7830.10 0.419 0.486 0.588 0.644 0.708 0.743 0.766

0.30 0.50 0.10 0.493 0.557 0.645 0.691 0.740 0.766 0.7830.30 0.450 0.516 0.611 0.663 0.718 0.749 0.7680.10 0.417 0.483 0.583 0.638 0.698 0.732 0.754

0.70 0.50 0.20 0.526 0.599 0.702 0.757 0.818 0.851 0.8720.30 0.467 0.541 0.649 0.711 0.780 0.819 0.8450.10 0.424 0.496 0.609 0.673 0.748 0.792 0.821

0.50 0.50 0.20 0.514 0.583 0.680 0.731 0.788 0.818 0.8380.30 0.460 0.531 0.635 0.693 0.756 0.792 0.8150.10 0.421 0.492 0.599 0.659 0.729 0.769 0.795

SHR NOM 1.50 SHR MAX 1.64

ULOR 0.000 DLOR 0.835 LOR 0.835

CIE FLUX CODE 51 85 95 100 83

270°

180°

90°

Angoli Gamma

180.0° 0.0°Semipiani C

180150135120

0

225

150

75

300

1530

60

75

90

105

cd/klm

Photometric data