8 7 6 5 4 3 1 2 - winnebago · 2016-09-22 · 20-sep-2016 . gen 4x4 box generator ground ground 6-3...
TRANSCRIPT
3.
265
ATS
1B1
CODES/STANDARDS-CSA/CMVSS265
302073-12
5
CLAMP TO FLOOR SUPPORT TUBES AS NECESSARYWITH CLAMP 10497-01-000.
302073-16
NOTES:
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
6
DRAWING NO FEATURE
302073-01 ------
SEE GENERATOR INSTALLATION FOR ADDITIONAL INFORMATION.
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.
5
1.
TO ABOVE FLOOR.
2651B1
INVERTER/CHARGERDETAIL DB
1B1 CODES/STANDARDS USA
WIRES THAT REST ON WIRE TRAYS ARE TO BETIED DOWN WITH WIRE TIE 8343-04-000.
6
CABLE ASM GENERATORFROM GENERATOR TO ATS6
4
2.
4
GROMMET23942-02-000
5
55
RCP-2 (BLU)EXT RCP
THROW IN WIRE #2
300 DROPPUR,GRY,YEL, & BRNSLIDE WIRES-ROOM #3 WIRES1,2,3 & 4DETAIL EB
300 DROPPUR,GRY,YEL & BRNSLIDE WIRES-ROOM #3 WIRES1,2,3 & 4DETAIL EC
BRN,PUR,YEL,GRY,WHT,RED,GRN,LT BLU,GLD,GLD2,BLU ARE ALL ROUTEDABOVE FLOOR
1000 DROP TO LOAD CENTERBLK, BLU, ORG1000 DROP BLUTHROW IN WIRE #71000 DROP INVERTER SUPPLY1000 DROP INVERTER RETURN1000 DROP LOAD CENTER MAIN
(ORG) 2200 LOOPTO ENG HTR SWITCHABOVE FLOOR HERE
AA
VIEW AA
PANEL-CLOSEOUT161260-05-CHTSCREWG39-08-12U (6)
RCP-1 (BLU)FREEZER
THROW IN WIRE #7 (BLU)
11E REFRIGERATOR/FREEZER PORTABL
11E
CLAMP10497-03-000 (3)SCREWG39-08-12U (3)
PANEL-CLOSEOUT171793-03-CHTSCREWG39-08-12U (9)
DA
GROMMET023942-02-000 (3)
5
TO GENERATOR
ATS
TO LOAD CENTER
RCP-1 (ORG)ENGINE HEATER
5
(BLK) 1200 DROP(BLU) 1500 DROPFROM LOAD CENTER TO110V SLIDE CONNECTION(BLU) 1200 DROPTHROW IN WIRE #2TO GALLEY GFI
11E
POWER CORD
3
UNSPECIFIED TOLERANCES: MATERIAL:
C
D
1
TWO-PLACE (X.XX)
DSNR:
DESCRIPTION:
8
2
B
ALL DIMENSIONS ARE IN MILLIMETERSDFTR:
6
A
6
FIRST USED:
A
REV
WHOLE DIM (X)
D
REF:
8
ITEM/PART NO:
4
WEIGHT: (LBS)
SHEET:
7
B
2
4
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
ANGLE
5
5
13
COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.
ONE-PLACE (X.X)
C
7
WIRING INSTL-BODY,110V
1 OF 6 000209110 / 30207301000
3
1.5
0.50
1
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
20-Sep-2016
2651B1
1B1 CODES/STANDARDS USA
265 CODES/STANDARDS-CSA/CMVSS3
1.
2.
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.
ALL 11OV WIRES TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.
NOTES:NOTES:
WIRE ROUTED IN SIDEWALL.
4
TO BED WALL RECPS (PUR)
CONNECTOR144283-02-000
LOAD CENTER/ATS191921-02-000
TO BELOW FLOOR.
RCP-2S (BLU)GALLEY 1
RCP-2S (BLU)GALLEY 2
SW-1 (ORG)ENGINE HEATER
RCP-2 (PUR)BED REAR
GFI-1 US (BRN)REAR BATH
RCP-2 (PUR)BED FRONT
RCP-B (DET BA)MID BATH
RCP-1 (DET BB)BED
GFI-1 CA (BRN)REAR BATH
RCP-1 (BLK)MICROWAVE
GFI-1 US (DET BE)GALLEY
GFI-1 CA (DET BE)GALLEY
110V CONNECTIONSDETAIL BC
EC
EA
4
4
4
110V CONNECTIONSDETAIL EA
110V CONNECTIONSDETAIL EC
110V WHT TOWATER HEATER
DETAIL BA
RCP-BMID BATH
(BRN)TO 110V CONNECTIONDETAIL EC
TO RCP-MID BATH
FROM REARBATH GFI
DETAIL BB
RCP-1BED
(PUR)RCP-B A/VDETAIL CB
TO 110V CONNECTIONDETAIL EC
FROM LOADCENTER
TO 110V CONNECTIONDETAIL EC
THROW IN WIRE #3
SLIDEOUT #2 WIRE #1SCREWG39-06-24B (8)
3
FROM 110V CONNECTIONDETAIL EC
CLAMP10495-01-000 (4)SCREWG39-10-12B (4)THROW IN WIRE #3
DETAIL BC
11E
11E
11E REFRIGERATOR/FREEZER PORTABL
THROW IN WIRE #7
RCP-B (DET BD)FREEZER
TO RCP-GFI GALLEY
RCP-BFREEZER(BLU)
TO RCP-1 FREEZER
DETAIL BD
FROM LOADCENTER
PANEL-RECEPTACLE188004-02-CHTSCREWG39-10-12U (2)
LABEL-ENG HTR083588-02-000
RCP-2 (BRN)LOUNGE
THROW IN WIRE #4
RCP-2 (BRN)MID BATH
THROW IN WIRE #1 (BLU)3
SP-05
THROW IN WIRE #4 (PUR)
THROW IN WIRE #2
TO 110V CONNECTIONDETAIL EA
RCP-GFIGALLEY(BLU)
TO RCP-2 EXT RCP
DETAIL BE
FROM LOADCENTER
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000209110 / 30207301000 2 OF 6
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
20-Sep-2016
2651B1
1B1 CODES/STANDARDS USA
265 CODES/STANDARDS-CSA/CMVSS
1. AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.
3
ALL 11OV WIRES TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.
2.
NOTES:
4
TO BELOW FLOOR.
5
WIRE ROUTED IN SIDEWALL.
3
4
4
COVER-WIRE153862-02-CHTSCREWG67-10-12B (4)
COVER-WIRE153862-02-CHTWIRE-COVER155469-01-CHTSCREWG67-10-12B (4)
EB
RCP-2 (PUR)PASS CABT RCP-1 (GRY)
FIREPLACE
RCP-2 (PUR)DESK FRONT
RCP-2 (PUR)DESK REAR
RCP-1 (YEL)REFRIGERATOR
RCP-B (DET CB)A/V
RCP-2 (BRN)BEDROOM
RCP-2 (BRN)REAR BATH
RCP-1 (GLD)DRYER
RCP-1 (GLD)WASHER
RCP-B (DET CC)FRONT A/C
RCP-B (DET CE)REAR A/C
RCP-B (DET CD)MID A/C
6
WIRE ROUTED IN ROOF.
FIREPLACE-ELECTRIC14CLABEL158542-01-CHT265
LABEL158542-01-CHT265
THROW IN WIRE #6(GRY)
110V CONNECTIONSDETAIL EB
14C
14CFIREPLACE-ELEC301314-01-CHTSCREWG11-08-12D (12)
TO REAR A/C
DETAIL CA
DETAIL CB
RCP-BA/V
(PUR)
FROMRCP-1 BED
DETAIL BCTO RCP-2FRONT SAT PREP
5
RCP-BFRONT A/C
(RED)
DETAIL CC
FROM LOADCENTER TO FRONT A/C
5
DETAIL CD
FROM LOADCENTER
RCP-BMID A/C(LT BLU)
TO MID A/C
DETAIL CE
FROM LOADCENTER
RCP-BREAR A/C
(GRN)
RCP-1 (PUR)SOUND BAR
RCP-2 (PUR)BEDROOM TV
RCP-2 (PUR)LOUNGE TV
FROM RCP-1SOUND BAR
4
TO RCP-2DESK REAR
4
RCP-2EXT TV(PUR)
RCP-2 (BRN)STOVE
4
RCP-EXT TV(REF)DETAIL CA
THROW IN WIRE #5(PUR)
5
5
SEE WIRING INSTL-BODY,12V FOR ADDITIONAL INFORMATION.
6
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000209110 / 30207301000 3 OF 6
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
20-Sep-2016
265
1B1 CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
1B1 265
POSITIVE BATTERYCABLE CONNECTION(FROM DISCONNECTSWITCH)
NEGATIVE BATTERYCABLE CONNECTION
REMOTE DISPLAY PANEL& AC TEMP SENSORCONNECTION
AC INPUT10 GA WIRE FROMMAIN BREAKER PANELSEE DETAIL DC
AC OUTPUT10 GA WIRE FROMINVERTER BREAKER PANELSEE DETAIL DC
2
INVERTER CHARGER2800 WATT PURE SINE175386-01-000NUTD39-04-00B (4)
WIRE ASM-GROUND
NOTES:
WIRE MUST BE ROUTED THROUGH CLAMPS AS SHOWN.1.
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.4
SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.2
4
VIEW DA
DETAIL DB
FLOOR ASM-LOWER(REF)
719
INVERTER/CHARGERDETAIL DB
BRACKET-MOUNT,INVERTER176315-16-CHTSCREWG39-08-12U (3)G39-08-24U (4)
3
JUMPER RECOMMENDED(HOT 2 IN)10 GA BLK (100MM)
DETAIL DC
NEUT OUT
JUMPER RECOMMENDED(HOT 1 OUT)10 GA BLK (100MM)
HOT 2 OUT
NEUT IN
AC GROUND
HOT 1 IN
2
DO NOT USE POWER/AIR TOOL TO INSTALL NUT.TORQUE TO 10-12 FT LBS.
3
3
SWITCH-BATTDISC 600 AMP186905-01-000BOLTG16-04-32U (4)NUTD39-04-00U (4)PANEL-CLOSEOUT161730-07-CHTSCREWG39-08-08U (4)LABEL186692-01-CHTDETAIL DD
INPUT
DETAIL DD
OUTPUT
PANEL-CLOSEOUT176812-12-CHTSCREWG39-08-12U (10)
SEAL132892-08-000(2000 MM)
PANEL-CLOSEOUT176812-13-CHTSCREWG39-08-12U (3)
SEAL(REF)
NOT USED
PANEL-CLOSEOUT176812-14-CHTSCREWG39-08-12U (10)
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000209110 / 30207301000 4 OF 6
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CABLE ASM-ORGFROM INVERTERPOSITIVE POST
INVERTERBATTERYDISCONNECT(REF)
20-Sep-2016
CODES/STANDARDS USA
265
1B1
14C
1B1
265
CODES/STANDARDS-CSA/CMVSS
FIREPLACE-ELECTRIC
DETAIL EC
DETAIL EBNOTES:
110V CONNECTORS ARE MOUNTED TO LEFT SIDEWALL.1
WIRE ROUTED IN SIDEWALL.2
DETAIL EA
3 110V CONNECTORS ARE MOUNTED TO STEEL TUBE INGALLEY CABINET.
BRACKET155223-12-CHTSCREWG39-08-12U (3)
BRACKET155223-04-CHTSCREWG39-08-12U (2)
CLAMP10495-01-000 (8)SCREWG39-08-08U (8)
CLAMP10495-01-000 (6)SCREWG39-08-08U (6)
2
14C
14C
14C
14C
(YEL)
CONNECTOR144283-02-000SCREWG39-06-24U (2)
CONNECTOR144283-02-000SCREWG39-06-24U (2)
SCREWG39-06-24U (8)
FROM DETAIL ECSEE SHT 1 FORWIRE ROUTING
SLIDEOUT #3 WIRE #4 (YEL)
SLIDEOUT #3 WIRE #2 (GRY)
SLIDEOUT #3 WIRE #1 (BRN)
FROM DETAIL EBSEE SHT 1 FORWIRE ROUTING
TO BEDSIDEWALL RCPSDETAIL BC
SLIDEOUT #2 WIRE #1 (PUR)
THROW IN WIRE #3 (PUR)
FROM RCP-1BED (PUR)DETAIL BC
FROM LOAD CENTER
SLIDEOUT #3 WIRE #3 (YEL)
SLIDEOUT #3 WIRE #2 (GRY)
SLIDEOUT #3 WIRE #3 (PUR)
(YEL)
(GRY)SCREWG39-06-24U (4)
SCREWG39-06-24U (14)
3
SLIDEOUT #1 WIRE #1 (BLU)
SCREWG39-06-24U (16)
2CLAMP10495-01-000 (8)SCREWG39-08-08U (8)
SLIDEOUT #3 WIRE #3 (PUR)
THROW IN WIRE #6 (GRY)
THROW IN WIRE #5 (PUR)
FROM LOAD CENTER(BLK)
FROM LOAD CENTER(BLU)
SLIDEOUT #1WIRE #2 (BLK)
THROW IN WIRE #1 (BLU)
(BLK)
BRACKET155223-05-CHT (2)SCREWG39-08-12U (4) SLIDEOUT #1
WIRE #1 (BLU)
CONNECTOR144283-02-000
SLIDEOUT #3 WIRE #1 (BRN)
(BRN)
TO GALLEY RCPS
(BRN)
SLIDEOUT #1WIRE #2 (BLK)
1
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000209110 / 30207301000 5 OF 6
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
20-Sep-2016
GEN4X4BOX
GENERATOR
GROUND
GROUND 6-3
8 GRN
WIRE SUPPLIEDWITH GENERATOR
POWERCORD
NOTES:
ALL OUTLETS DOWN STREAM AND INCLUDING THISOUTLET ARE GROUND GAULT INTERUPT PROTECTED.
WIRE ROUTED IN ROOF.
WIRE ROUTED IN SIDEWALL.
2
1
3
4
AUX GEN
GEN L1 GEN NEUT LINE L2 LINE NEUT LOAD L2 LOAD AUX
GEN L2 LINE L1 LINE AUX LOAD L1 LOAD NEUT
GROUND GROUND GROUND
GROUND
RCP-GFIREAR BATH
REARA/C
RCP-DESK
FRONT
RCP-BLANK,
ROOF
1
6-3
BLK RED
RED BLK RED BLK
R1
L1
R3
L1
N
L2
R5
L2
R7
12-2 14-2
14-2
12-2
6-3
6-3
12-2
12-2
14-2
14-2
14-2
14-2
14-2
14-2
3
SLIDEOUT #1WIRE #2
110V CONNECTION(UNDER LEFT LAV)
RCP-MICROWAVE
110V CONNECTION(UNDER GALLEY)
110V CONNECTION(UNDER FBUFFET TABLE)
RCP-REFRIG
SLIDEOUT #3WIRE #4
110V CONNECTION(UNDER BED)
110V CONNECTION(BEHIND LOAD CENTER)
110V CONNECTION(IN WARDROBE)
RCP-FIREPLACE
SLIDEOUT #3WIRE #2
RCP-EXTERIOR
RCP-GALLEY #1
110V CONNECTION(UNDER GALLEY)
SLIDEOUT #1WIRE #1
110V CONNECTION(UNDER FRONT
LAV)
RCP-GFIGALLEY
INVERTER
MIDA/C
FRONTA/C
RCP-BLANK,
ROOF
THROW IN WIRE #3 110V CONNECTION(UNDER BED)
110V CONNECTION(BEHIND LOAD CENTER)
RCP-BED,REAR
RCP-BA/V
RCP-LOUNGE
TV
2
RCP-FRONTSAT PREP
SLIDEOUT #2WIRE #1
EMSMODULE
LINE 1 (BLK) ROUTED THRU THIS CURRENT SENSOR
5 LINE 2 (RED) ROUTED THRU THIS CURRENT SENSOR
4
5
WATERHEATERWHT
1 BLK
RCP-WASHERGLD
GLD-2 RCP-DRYER
ORGRCP-
ENGINEHEATER
ENGINEHEATERSWITCH
2 2
2
14-2
1
RCP-REAR BATH
THROW IN WIRE #2
RCP-PASSENGERSCOUNSEL
RCP-FRONT OVHD
RCP-BLANK,LOAD CENTER
SLIDEOUT #3WIRE #3
110V CONNECTION(BEHIND
LOAD CENTER)
110V CONNECTION(IN WARDROBE)
3
RCP-BED,FRONT
THROW IN WIRE #3 (REF)
RCP-BLANK,
ROOF
THROW IN WIRE #5
RCP-EXT TV
RCP-BEDROOM
RCP-DVD PLAYER
RCP-GALLEY #2
11ERCP-BLANK,FREEZER
THROW IN WIRE #7
RCP-FREEZER 11E
265 CODES/STANDARDS-CSA/CMVSS
1B1
REFRIGERATOR/FREEZER PORTABL
CODES/STANDARDS USA
1B1
11E
265
RCP-DESKREAR
3
RCP-BEDROOM
TV
3
RCP-SOUND
BAR
3
3RCP-
FRONTBATH
THROW IN WIRE #4
SLIDEOUT #3WIRE #1
THROW IN WIRE #1THROW IN WIRE #6
3
110V CONNECTION(IN WARDROBE)
110V CONNECTION(BEHIND LOAD CENTER)
RCP-STOVE
RCP-BBATH
RCP-LOUNGE
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000209110 / 30207301000 6 OF 6
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
20-Sep-2016