    SIPROTEC 5

    Configuration

    Mar 11, 2014 1:18 PM

    Device: 7UT85 Transf. Prot (2 Wind.)

    Product codeShort: P1F25577Long: 7UT85-DAAA-AA0-0AAAA0-AC0111-12112A-AAA000-000AA0-CC1BA1-CP3

    Housing width: 3/6 x 19"Housing type: Flush mountingBinary inputs: 9Binary outputs: 12 Relays (3 Standard, 9 Fast, 0 High-Speed, 0 Power)Current transformers: 8 for protection, 4 for measurement and sensitive ground-current detectionVoltage transformers: 4

    Modules in 19" row 1: IO203 , PS201 , IO214Modules in 19" row 2:Number of LEDs: 16Operation Panel: IntegratedKey switch: WithoutDisplay type: Small displayFront Design: StandardPower Supply: DC 60 V-250 V, AC 100 V-230 V

    Communication:Communications encryption: NormalIntegrated Ethernet port J: DIGSI 5 and IEC 61850/limited

    Plug-in module position E: Port is available but not assembledPlug-in module position F: Port is available but not assembled

    Functions:Function points class: Base + 20 function points

    Note on function-points class

    The function-points class results from the sum of the function points of the selected functions. You can apply thesefunctions as selected. The device allows also each other selection of functions as long as the sum of the requiredfunction points is within the selected function-points class. With the maximum function-points class of 1400 it ispossible to activate all the functions in the device. The function-points exceeding 1400 are free of charge. In theengineering phase DIGSI 5 checks that the selected configuration is suitable (capable of running in the device) beforeloading it to the device.

  • 8/12/2019 7UT85_CANTAYUS

    2/5

    SIPROTEC 5

    Configuration

    Mar 11, 2014 1:18 PM

    Miscellaneous:Warranty: 5 yearsFirmware: Current version

  • 8/12/2019 7UT85_CANTAYUS

    3/5

    SIPROTEC 5

    Configuration

    Mar 11, 2014 1:18 PM

    Functional scope 7UT85 Transf. Prot (2 Wind.):

    Add selected ResultANSI Function Abbr.

    Alwaysincluded Qty. x Value = Points Qty.

    Hardware quantity structure expandable I/O

    21/21N Distance protection Z x 5 =

    46 Unbalanced-load protection (thermal) I2 t> x 5 =

    49 Thermal overload protection , It

    49H Hot spot calculation h, It x 20 =

    50/51TD

    Overcurrent protection, phases I>

    50N/51N TD

    Overcurrent protection, ground IN>

    50HS High speed instantaneous overcurrentprotection

    I>>>

    50N/51N TD

    Overcurrent protection, 1-phase IN>

    50Ns/51Ns

    Sensitive ground-current protectionfor systems with resonant or isolatedneutral

    INs> x 5 =

    50BF Circuit-breaker failure protection, 3-pole CBFP x 5 =

    59 Overvoltage protection, 3-phase V> x 5 =

    59 Overvoltage protection, positive-sequence system

    V1> x 5 =

    59 Overvoltage protection, negative-sequence system

    V2> x 5 =

  • 8/12/2019 7UT85_CANTAYUS

    4/5

  • 8/12/2019 7UT85_CANTAYUS

    5/5

    SIPROTEC 5

    Configuration

    Mar 11, 2014 1:18 PM

    Functional scope 7UT85 Transf. Prot (2 Wind.):

    Add selected ResultANSI Function Abbr.

    Alwaysincluded Qty. x Value = Points Qty.

    CFC standard

    CFC arithmetic x 40 =

    CFC switching sequences for controlapplications

    x 40 =

    Inrush current detection

    External trip initiation

    Control

    Fault recording of analog and binarysignals

    Monitoring and supervision

    Protection interface, serial

    Circuit Breaker 4x x 3 = 4x

    Disconnector 4x x 3 = 4x

    Sum: 15