HUAWEI TECHNOLOGIES Co., Ltd.

RRU3008 V300

Installation Guide

Issue: 11Date: 2010-05-20

Page 2: 75357582-RRU3008-Installation-Guide-V300-11-1

1

Contents

Copyright © Huawei Technologies Co., Ltd. 2010. All rights reserved.

1. Safety Information ……………………………………………………………………………………….....

2. Installation Tools ……………………………………………………………………………………….......

3. Installing the DC RRU3008 ………………………………………………………………………………..

Installation Modes ………………………………………………………………….........................

Space Requirements………………………………………………………………….. ……………

Installation Procedure ………………………………………………………………………………..

Preparing for the Installation ………………………………………………………………………..

Installing the RRU on a Metal Pole ……………………………………………………………….

Installing Two RRUs in Back-To-Back Mode …………………………………………………….

Installing the RRU on a Wall ……………………………………………………………………….

Installing the RRU on a U-Steel ……………………………………………………………………

Installing the RRU on an Angle Steel ……………………………………………………………..

Installing the RRU on an H-shaped Stand ………………………………………………………..

Cable Connections of a Single RRU ………………………………………………………………

Cable Connections of Multiple RRUs ……………………………………………………………..

Cable List …………………………………………………………………………………………….

Installing the RRU Cables ………………………………………………………………………….

RRU Cable Installation Scenarios …………………………………………………………………

4. Installing the AC RRU3008 ……………………………………………………………………………….

Space Requirements..………………………………………………………………... ……………

Installation Modes ………………………………………………………………………………….

Installing the Surge Protection Box (for Outdoor Scenarios) …………………………………...

Cable Connections of a Single RRU ………………………………………………………………

Cable Connections of Multiple RRUs ……………………………………………………………..

List of Cables (No Surge Protection Box Configured) …………………………………………..

List of Cables (Surge Protection Box Configured) ……………………………………………….

Installing the RRU Cables ………………………………………………………………………….

Installation Checklist ……………………………………………………………………………….

5. Powering On the RRU ……………………………………………………………………………………

6. Reference ………………………………………………………………………………………………….

Binding the RRU and Installation Components …………………………………………………

Making OT Terminals by Using a Cable Peeler (Recommended) ……………………………

Making OT Terminals at the Input End of the Power Cable by Using a Knife ………………

Installing the Corrugated Pipes of AC Power Cable …………………………………………..

Pin Assignment for the Wires of the RRU Alarm Cable (DC) …………………………………

7. Changes History ………………………………………………………….. ………………………………

2

3

4

4

5

6

6

7

9

10

11

11

12

14

14

15

17

19

31

31

31

32

36

37

37

39

41

43

44

45

46

46

47

48

48

49

Page 3: 75357582-RRU3008-Installation-Guide-V300-11-1

2

Safety Information

Following All Safety PrecautionsBefore any operation, read the instructions and precautions in this document carefully to minimize the possibility of accidents.The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be followed. They only provide the generic safety precautions for operations.When operating Huawei products and equipment, you must comply with safety precautions and special safety instructions related to corresponding equipment provided by Huawei. The safety precautions in the document are related to only Huawei products. Huawei is not liable for any consequence that results from the violation of universal regulations for safety operations and safety codes on design, production, and equipment use. Complying with the Local Safety RegulationsWhen operating the device, comply with the local safety regulations. The safety precautions provided in the documents are supplementary. Qualified Personnel OnlyThe personnel in charge of installation and maintenance must be trained and master the correct operating methods and safety precautions before beginning work.Symbols

Safety of Personnel• The high voltage power supply provides power for running the system. Direct contact with the high voltage power supply or contact through damp objects may result in fatal danger.• Non-standard and improper high voltage operations may result in fire and electric shock.• In a thunderstorm, do not perform operations on high voltage and AC power supply facilities or on a steel tower and mast.• Ground the device before powering on the device. Otherwise, the personnel and device are in danger.• Power off the device before performing operations on the power supply equipment.• High power radio-frequency signals are harmful to human body. Before installing or maintaining an antenna on a steel tower or mast with a large number of transmitter antennas, the operator should coordinate with all parties to ensure that the transmitter antennas are shut down.• When handling optical fibers, do not stand close to, or look into the optical fiber outlet with unaided eyes.• Protect yourself when drilling holes. Flying dust may hurt your eyes or you may inhale the dust.• Power off the batteries before connecting the cables to the batteries. Otherwise, casualties may occur. • When working at a height, be cautious about falling objects.Device Safety• Check the electrical connection of the device before operation and ensure that the device is reliably grounded.• The static electricity generated by the human body may damage the electrostatic sensitive components on the circuit board, such as the large-scale integrated circuit (LIC). Wear an electrostatic discharge (ESD) wrist strap or ESD gloves when performing the operation.• When working on batteries, take measures to prevent short circuits in the batteries and electrolyte spill/loss. The electrolyte may erode metal and boards, or even cause rust of the equipment or short circuits in the boards.• When the equipment is unpacked, it must be powered on in 24 hours. The maximum duration of the power-off state of the equipment is 24 hours during maintenance.

Indicates a hazard with a high level of risk, which if not avoided, will result in death or serious injury.DANGER

WARNING

CAUTION

TIP

NOTE

Indicates a hazard with a medium or low level of risk, which if not avoided, could result in minor or moderate injury.Indicates a potentially hazardous situation, which if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.

Indicates a tip that may help you solve a problem or save time.

Provides additional information to emphasize or supplement important points of the main text.

Page 4: 75357582-RRU3008-Installation-Guide-V300-11-1

3

Installation Tools

Multimeter

Knife

Hammer drill(with bit 14) Vacuum cleaner

Claw hammer

ESD gloves

Heat gunFlat-head screwdriver

(M3~M6)

Wire stripper

Wire cutterPower cable crimping pliersAdjustable wrench

(with the diameter of at least 32 mm)

Torque screwdriver

Measuring tape

Level

Marking pen(with the diameter of no more

than 10 mm)

Combination wrench(21mm~21mm) for pole installation

(17mm~17mm) for wall installation

Phillips screwdriver

(M3~M6)

Torque wrench

Page 5: 75357582-RRU3008-Installation-Guide-V300-11-1

4

The following figure describes the specifications for the metal pole, angle steel, and U-steel where the RRU is installed.

As shown in the figure, the angle between the vertical and the angle steel or U-steel where the RRU is installed must be Less than or equal to 10 degree.

Metal pole Angle steel U-steel

the angle steel or U-steel

a Installation Modes

Installing the DC RRU3008

Only one RRU can be installed on a U-steel or angle steel at the back.

A single RRU can be lifted to the tower. For details, see page 45.

On a metal pole

(Back-To-Back Mode)

On a metal pole On a wall On an angle steel On a U-steel On an H-shaped stand

The maximum bearing capability of the wall equals to four times of the RRU weight, and a single RRU3008 weighs 23 kg. When the RRU is mounted on the wall, tighten the expansion bolts to 30 N·m. Ensure that the expansion bolts are properly tightened and there is no crack on the wall.

WARNING

60 mm~114 mm

63mm

80mm

63 mm~80 mm

63 m

m~8

0 m

m

50 mm~100 mm

30m

m~5

0mm

Page 6: 75357582-RRU3008-Installation-Guide-V300-11-1

5

Installing the DC RRU3008

4. Clearance for Two Combined RRUs

2. Recommended Clearance for a Single RRU

3. Minimum Clearance for a Single RRU

1. RRU Dimensions

b Space Requirements

(Unit: mm) (Unit: mm)

(Unit: mm) (Unit: mm)

Page 7: 75357582-RRU3008-Installation-Guide-V300-11-1

6

c Installation Procedure

d Preparing for the Installation

Installing the DC RRU3008 Installing the DC RRU3008

Fixture assembly for installing the RRU Front of the RRU Back of the RRU

Cover plate

Attachment plate

Main fixture

Auxiliary fixture

Dual-nut bolt assembly

Prepare the installation

Start

End

Power on the RRU

Install the cables of RRU

Page 8: 75357582-RRU3008-Installation-Guide-V300-11-1

7

e Installing the RRU on a Metal Pole

Installing the DC RRU3008

1. Install the main fixture.

When installing the main fixture, ensure that the contact piece on the fixture is fixed and the arrow on the main fixture is upward.

It is recommended that the bottom of the highest main fixture be 1200 mm to 1600 mm above the ground for easy maintenance.Arrow

2. Install the auxiliary fixture between the nuts of the dual-nut bolt assembly on the main fixture.

Ensure that the arrowon the auxiliary fixture is upward.

dual-nut

You may fit one end of the auxiliary bracket on one dual-nut bolt assembly and the other end on the other dual-nut bolt assembly during the installation.

Page 9: 75357582-RRU3008-Installation-Guide-V300-11-1

8

Installing the DC RRU3008

3. Use an adjustable wrench to tighten the nut until the fastening torque is 40 N•m. In this way, the main and auxiliary fixtures are secured on the pole.

4. Install the RRU on the main bracket. When you hear a click, you can infer that the RRU is in position.

The screw is a non-fixed one and can be neglected during the installation.It is only used when the RRU is removed.

The RF port at the bottom of the RRU does not have load bearing capacity. Do not place the RRU on the ground on its bottom during the installation.

Fasten the two dual-nut bolt assemblies alternatively. After the brackets are secure, use a tape to measure the spacing between the main bracket and the auxiliary bracket at the two sides and ensure that the spacing is the same.

e Installing the RRU on a Metal Pole

40N•m

Page 10: 75357582-RRU3008-Installation-Guide-V300-11-1

9

Installing Two RRUs in Back-To-Back Modef

4. Install the second RRU on the main fixture.

3. Reinstall the cover plate and attachment plate on the second RRU to interchange their positions.

1. Install an RRU first. For details, see page 7.

Installing a Single RRU in Ordinary Mode.

2. Install the main fixture of another RRU. Ensure that the main and auxiliary fixtures are perfectly fitted.

Installing the DC RRU3008

When the surfaces of the main and auxiliary brackets are in the same plain, you can infer that the main bracket is properly installed.

M6×16 bolt

Page 11: 75357582-RRU3008-Installation-Guide-V300-11-1

10

Do not hammer the bolt entirely into the expansion tube, and leave 20 mm to 30 mm of the bolt outside the wall.

1. Place the auxiliary fixture on the wall at the installation position and then mark the anchor points by using a marking pen.

2. Drill holes at the anchor points and then install the expansion bolt assemblies.

g Installing the RRU on a Wall

Installing the DC RRU3008

3. Fit the auxiliary fixture on the expansion bolts downward, and then tighten the bolts by using a combination wrench (17 mm).

4. Install the main bracket, and then use a level bar to adjust the levelness of the bracket.

5. Install the RRU.

It is recommended that the bottom of the auxiliary fixture be 1200 mm to 1600 mm above the ground.

After the expansion bolt is removed, dispose of the plastic tube.

55~60mm

90°

Ø14

Bolt M10×65Spring washer 10Plastic tubeFlat washer 10Expansion tube

30N•m

M10X65

Page 12: 75357582-RRU3008-Installation-Guide-V300-11-1

11

h Installing the RRU on a U-Steel

i Installing the RRU on an Angle Steel

Installing the DC RRU3008

The procedure for installing the RRU on a U-steel is the same as that on a metal pole.Only one RRU can be installed on a U-steel at the back.

U-steel

Angle steel

Top view

Four installation modes

Top view

The procedure for installing the RRU on an angle steel is the same as that on a metal pole.Only one RRU can be installed on an angle steel at the back.

Page 13: 75357582-RRU3008-Installation-Guide-V300-11-1

12

Installing the DC RRU3008Installing the RRU on an H-shaped Stand j

3. Install the horizontal beam.1. Secure the stand. 2. Adjust the levelness of the stand.

Pretightening

Tightening

The horizontal beam on the other side is installed in the same way.

Page 14: 75357582-RRU3008-Installation-Guide-V300-11-1

13

Installing the DC RRU3008

j Installing the RRU on an H-shaped Stand 4. Install the main bracket. 5. Mount the RRU on the main bracket

Expansion bolt

6. Install the RRU.

Use expansion bolts to fasten the main bracket. Ensure that the expansion tubes and plastic tubes must be removed before the expansion bolts are installed.Use the expansion bolts in the installation kit delivered with the RRU. Do not use other types of expansion bolts.When the RRU is installed on a wall, the angle between the wall and the RRU should not exceed two degrees.

Installing the support

RRU

≤2°

Do not install three or four RRUs on a single H-shaped stand.

Page 15: 75357582-RRU3008-Installation-Guide-V300-11-1

14

① CPRI optical cable② DC RRU power cable③ RRU RF jumper④ PGND cable⑤ SFP high-speed cable

for cascading⑥ DC RRU alarm cable

External alarm device

External power supply

External alarm device

External power supply

Ante

nna

k Cable Connections of a Single RRU

l Cable Connections of Multiple RRUs

Installing the DC RRU3008

① DC RRU alarm cable② CPRI optical cable③ DC RRU power cable④ RF cable between RFUs⑤ AISG multi-wire cable between the RRU and the RCU⑥ RRU RF jumper⑦ Feeder⑧ AISG extended cable between the RRU and the RCU⑨ PGND cable

Ante

nna

Ante

nna

Ante

nna

The RRU3008 does not support the cascading of power cables.When two or more RRUs need to be cascaded in the same cell (or in the scenario for capacity expansion), the alarm cables need to be connected to the RRU in the lowest level for alarm reporting.

Install the PGND cable

Install the RF jumper(RF cable between RFUs is

optional)

Install the DC RRU power cable

Install the CPRI optical cable

Install the DC RRU alarm cable(optional)

Install the AISG multi-wire cable between the RRU and the RCU

(optional)

Install the AISG multi-wire cable between the RRU and the RCU

(optional)

When a dual-polarized antenna is shared by two RRUs in the same sector, the two RRUs are connected through a RF cable between RFUs. The connections of three RRUs in the same sector are not supported.

Page 16: 75357582-RRU3008-Installation-Guide-V300-11-1

15

m Cable List

Installing the DC RRU3008

Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU

DLC connectorCPRI optical cable

Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI5 ports on the GTMU

DLC connector

Port labeled RET on the RRUWaterproof DB9 connectorAISG multi-wire cable between the RRU and the RCU Standard AISG male connector of the AISG

extension cable or RCUStandard AISG female connector

The OT terminal on the blue wire is connected to the NEG(-) port on the cabling cavity of the RRU. The OT terminal on the black wire is connected to the RTN(+) port on the cabling cavity of the RRU

Two OT terminals ( 6 mm²-M4 )DC RRU power cable

( North American standard: 12AWG

European standard:

4 mm² )

External power supplyBare wire

Feeder or antennaDIN male connector

Ports labeled ANT-A and ANT-B on the RRUDIN male connectorRRU RF jumper

Nearest grounding barOT terminal ( M8 )

Grounding bolt on the RRUOT terminal ( M6 )PGND cable

(16 mm²)

Connected to…Connector TypeCable

Page 17: 75357582-RRU3008-Installation-Guide-V300-11-1

16

Installing the DC RRU3008

Port labeled EXT_ALM in the RRU cabling cavityDB15 male connectorDC RRU alarm cable

External alarm devicesEight cord end terminals

the CPRI_W port on the upper-level RRUSFP200 male connectorSFP high-speed cable for cascading the CPRI_E port on the lower-level RRUSFP200 male connector

Port labeled RX_IN/OUT on the lower-level RRU2W2 connector

Port labeled RX_IN/OUT on the upper-level RRU2W2 connectorRF cable between RRUs

Standard AISG male connector of the RCUStandard AISG female connector

Standard AISG female connector of the AISG multi-wire cable

Standard AISG male connector

AISG extended cable between the RRU and the RCU

Connected to…Connector TypeCable

Coil the extra length of a cable, and then connect the cable to the corresponding port according to actual installation scenario.

m Cable List

Page 18: 75357582-RRU3008-Installation-Guide-V300-11-1

17

n Installing the RRU Cables

Installing the DC RRU3008

1. Opening the Cover Plate of the RRU Cabling Cavity.

2. The Cabling Cavity of the RRU.

Cable trough for the power cable

Cable trough for the optical cable

Cable trough for alarm cable

Waterproof filler

Cover plate of the cabling cavity

Cabling cavity

Reference for makingthe power cable

Page 19: 75357582-RRU3008-Installation-Guide-V300-11-1

18

n Installing the RRU Cables

Installing the DC RRU3008

3. Cable Connections of RRU.

CPRI optical cable

DC RRU alarm cable

Shielding layer of the power cable

DC RRU power cable

First wrap the joint with the waterproof tape, and then wrap itwith the PVC insulating tape.

Grounding boltOT terminalPGND cable

Case 1

RRU RF jumper

Waterproofed alarm cable

Case 2

For details on how to add the OT terminals to the DC RRU power cable, see page 47.

4. Closing the Cover Plate of theRRU Cabling Cavity.

The screw on the cover plate is tightened until the fastening torque is 14 kgf•cm.The screws on the cover plate are tightened in the order shown in the preceding figure.The tape is wrapped spirally upwards, downwards, and then

upwards again in three layers. For every two adjacent tape layers, the tape on the upper layer overlaps about half the width of the tape on the lower layer.Do not remove the dustproof cap from the feeder connectors that are not in use. In addition, protection measures against damp, dust, and salt mist must be taken. If the RRU is installed outdoors, you also need to wrap the joint with waterproof tape.

Press the strap on the exposed shielding layer of the power cable tightly. Ensure that the lower edge of the exposed shield layer does not exceed the position shown in the figure.The alarm cable is preferably led out of the RRU from the narrower cable trough in the middle of the cabling cavity. If the cable trough is used by the CPRI optical cable, the alarm cable is led from the wider cable trough near the middle one. In this case, the alarm cable must be wrapped with 10 to 17 layers of waterproof tape so that the diameter of the cable reaches 10 mm to 12 mm.To avoid sharp bending, the optical cable must be pressed by the strap next to the power cable during the optical cable installation.Waterproof fillers should be installed in the unused cable trough.

Page 20: 75357582-RRU3008-Installation-Guide-V300-11-1

19

Installing the DC RRU3008

o RRU Cable Installation Scenarios

The DC RRU power cable is connected to one of the LOAD4 to LOAD9 terminals of the PDU.Strip the jacket of the DC RRU power cable for a small part, press the exposed shielding layer on the strap, and then connect the PGND cable on the strap to the nearest grounding bolt on the side in the APM30.

(2)CPRI optical cable(1) DC RRU power cable

RRU and BBU are on the same site, and the BBU monitors the APM30.

1.1 RRU+APM30/APM30H(Ver.A).

shielding layer (25 mm)

Page 21: 75357582-RRU3008-Installation-Guide-V300-11-1

20

X8 X9

X6 X7

Installing the DC RRU3008

(2)CPRI optical cable (3) DC RRU alarm cable(1) DC RRU power cable

o RRU Cable Installation Scenarios

The RRU and BBU are not on the same site, and the RRU monitors the APM30.

The DC RRU power cable is connected to one of the LOAD4 to LOAD9 terminals of the PDU.Strip the jacket of the DC RRU power cable for a small part, press the exposed shielding layer on the strap, and then connect the PGND cable on the strap to the nearest grounding bolt on the side in the APM30.

RX-X6White/green

RX+X7Twisted pairGreen

TX-X8White/brown

TX+X9Twisted pairBrown

Port on the APMIPinsWire TypeWire Color of the Alarm Cable

shielding layer (25 mm)

1.2 RRU+APM30/APM30H(Ver.A).

Page 22: 75357582-RRU3008-Installation-Guide-V300-11-1

21

Installing the DC RRU3008

o RRU Cable Installation Scenarios

The DC RRU power cable is connected to one of the LOAD8 to LOAD13 terminals of the EPS. Strip the jacket of the DC RRU power cable for a small part, press the exposed shielding layer on the strap,

(2)CPRI optical cable(1) DC RRU power cable

RRU and BBU are on the same site, and the BBU monitors the APM30H.

shielding layer (25 mm)

1.3 RRU+APM30H(Ver.B).

RRU

Page 23: 75357582-RRU3008-Installation-Guide-V300-11-1

22

COM_IN

RRU

Installing the DC RRU3008

(2)CPRI optical cable (3) DC RRU alarm cable(1) DC RRU power cable

o RRU Cable Installation Scenarios

The RRU and BBU are not on the same site, and the RRU monitors the APM30H.

1.4 RRU+APM30H(Ver.B).

shielding layer (25 mm)

The DC RRU power cable is connected to one of the LOAD8 to LOAD13 terminals of the EPS. Strip the jacket of the DC RRU power cable for a small part, press the exposed shielding layer on the strap,

Page 24: 75357582-RRU3008-Installation-Guide-V300-11-1

23

2. RRU+19-Inch Stand.

o RRU Cable Installation Scenarios

Installing the DC RRU3008

The DC RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B.When connecting the DC RRU power cable to the DCDU-03B, you must add an OT terminal to the shielding layer. Then, fix the OT terminal to the corresponding PGND terminal of the DCDU-03B. For details on how to add an OT terminal, see page 47.

(2) CPRI optical cable(1) DC RRU power cable

BBU

DCDU-03B

LOAD0

Shielding layer of DCRRU power cable

Page 25: 75357582-RRU3008-Installation-Guide-V300-11-1

24

LOAD0

3. RRU+Wall-Mounted BBU.

o RRU Cable Installation Scenarios

Installing the DC RRU3008

The DC RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B.When connecting the DC RRU power cable to the DCDU-03B, you must add an OT terminal to the shielding layer. Then, fix the OT terminal to the corresponding PGND terminal of the DCDU-03B. For details on how to add an OT terminal, see page 47.

(2) CPRI optical cable(1) DC RRU power cable

The DCDU panel must face right side and the BBU panel must face downwards.

Shielding layer of DC RRU power cable

Page 26: 75357582-RRU3008-Installation-Guide-V300-11-1

25

o RRU Cable Installation Scenarios

Installing the DC RRU3008

4. RRU+H-shaped stand +RRU3004 Rack (-48 V power supply ).

The DC RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B.

(2) DC RRU power cable (3) DCDU power cable (4) RRU RF jumper(1) CPRI optical cable

LOAD0

Shielding layer of DC RRU power cable

Page 27: 75357582-RRU3008-Installation-Guide-V300-11-1

26

o RRU Cable Installation Scenarios

Installing the DC RRU3008

5. RRU+H-shaped stand +RRU3004 Rack (220 V power supply ).

(2) DC RRU power cable (3) 4815 power cable (4) RRU RF jumper(1) CPRI optical cable

The DC RRU power cable is connected to the OUTPUT RRU terminal of 4815.

Page 28: 75357582-RRU3008-Installation-Guide-V300-11-1

27

LOAD0

6. RRU+PS4890.

o RRU Cable Installation Scenarios

Installing the DC RRU3008

(2) CPRI optical cable(1) DC RRU power cable

The DC RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B.When connecting the DC RRU power cable to the DCDU-03B, you must add an OT terminal to the shielding layer. Then, fix the OT terminal to the corresponding PGND terminal of the DCDU-03B. For details on how to add an OT terminal, see page 47.

Shielding layer of DC RRU power cable

Page 29: 75357582-RRU3008-Installation-Guide-V300-11-1

28

Installing the DC RRU3008

p RRU Cable Installation Scenarios7.1. 220 V AC input (4815 installed in the OMB cabinet).

7.2. –48 V DC input input (DCDU-03C installed in the OMB cabinet).

The DC RRU power cable is connected to terminals of the 4815 power system for RRU.

Strip the jacket of the DC RRU power cable for a small part, press the exposed shielding layer on the strap, and then connect the PGND cable on the strap to the nearest grounding bolt on the side in the OMB cabinet.

The DC RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B.

shielding layer (25 mm) PGND

shielding layer (25 mm) PGND

(2) CPRI optical cable

(1) DC RRU power cable

(2) CPRI optical cable

(1) DC RRU power cable

Page 30: 75357582-RRU3008-Installation-Guide-V300-11-1

29

8.1. RRU+TMC.

o RRU Cable Installation Scenarios

Installing the DC RRU3008

The DC RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B.When connecting the DC RRU power cable to the DCDU-03B, you must add an OT terminal to the shielding layer. Then, fix the OT terminal to the corresponding PGND terminal of the DCDU-03B. For details on how to add an OT terminal, see page 47.

(2) CPRI optical cable(1) DC RRU power cable

Page 31: 75357582-RRU3008-Installation-Guide-V300-11-1

30

8.2. RRU+TMC11H.

o RRU Cable Installation Scenarios

Installing the DC RRU3008

The DC RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B.Strip the jacket of the DC RRU power cable for a small part, press the exposed shielding layer on the strap.

(2) CPRI optical cable(1) DC RRU power cable

Page 32: 75357582-RRU3008-Installation-Guide-V300-11-1

31

Space Requirementsb

Installing the AC RRU3008

The recommended/minimal clearance ,for the AC RRU/clearance for two ,combined RRUs , is the same as that for ,the DC RRU. For details, see page 5.

b Installation Modesa

On a metal pole On a wall On an angle steel On a U-steel

The AC RRU3008 cannot be side-mounted. When it is installed in other modes, the procedure is the same as that of the DC RRU3008.

For details, see page 7 to page 12.

On an H-shaped stand

The maximum bearing capability of the wall equals four times of the RRU weight, and a single AC RRU3008 weighs 30 kg. When the RRU is mounted on the wall, tighten the expansion bolts to 30 N·m. Ensure that the expansion bolts are properly tightened and there is no crack on the wall.

WARNING

(Unit: mm)

Page 33: 75357582-RRU3008-Installation-Guide-V300-11-1

32

Installing the Surge Protection Box (for Outdoor Scenarios)c

Dimensions of the surge protection box Minimal/Recommended clearance for the surge protection box

Installation of the surge protection box

Installing the AC RRU3008

the surge protection box

Loop iron

(Unit: mm) (Unit: mm)

Page 34: 75357582-RRU3008-Installation-Guide-V300-11-1

33

2. Open the cover of the surge protection box(by unfastening the screws with the torque of 48 kg f•cm).

1. Install the surge protection box on the metal pole.

1.1 As shown in the figure, unfasten the screw on the loop iron.1.2 Lead the loop iron through the opening between the back plate

of the surge protection box and the surge protection box.1.3 Circle the loop iron around the metal pole, and then tighten the

screw on the loop iron with the torque of 48 kg f•cm.

Installing the surge protection box on the wall

1. when installing the surge protection box, you need to dispose of the plastic tube on the expansion bolt.

2.The procedure for installing the surge protection box on the wall is the same as that for installing the RRU on the wall. For details, see page 10.

Installing the AC RRU3008

Installing the Surge Protection Box (for Outdoor Scenarios)c

M4

If the loop is installed on a pole with a smaller diameter, the extra part of the loop should be cut.

Page 35: 75357582-RRU3008-Installation-Guide-V300-11-1

34

(The cable led through the PG connector labeled OUT is the power cable between the RRU and the surge protection box, and the cable led through the PG connector labeled IN is the external AC power cable.)

6. Close the cover of the surge protection box, and then tighten the screws. (You should tighten the screws in the order shown in the figure with the torque of 14 kg f•cm).

3. Lead the external AC power cable through the PG connector labeled IN. The L, N, and PE wires of the power cable are connected to the Lin, Nin, and PE terminals on the surge protection box.

4. Lead the power cable between the RRU and the surge protection box through the PG connector labeled OUT. The L, N, and PE wires of the power cable are connected to the Lout, Nout, and PE terminals on the surge protection box.

5. Tighten the PG connector, and then use a wrench to further tighten the connector for one or two laps to ensure its waterproofing capability.

Installing the AC RRU3008

Installing the Surge Protection Box (for Outdoor Scenarios)c

M4

Install the corrugated pipes for the AC power cables before installing the AC RRU power cables. For details, see page 48.

PG connector

Lead the cable through the removed thread-lock sealing nut, and then lead the cable through the PG connector.The removed thread-lock sealing nut of the PG connector cannot be replaced with the thread-lock sealing nuts of other surge protection boxes.Ensure that the case of the cable shielding layer is tightly pressed by the strap.

Thread-lock sealing nut

OUT IN

Page 36: 75357582-RRU3008-Installation-Guide-V300-11-1

35

OUT

AC IN

8. Connect the power cable between the surge protection box and the RRU.

7. Connect the PGND cable.

2. Connect the PGND cable between the surge protection box and the RRU.1. Connect the external PGND cable between the surge protection box and the grounding point.

Installing the AC RRU3008

Installing the Surge Protection Box (for Outdoor Scenarios)c

Install the corrugated pipes for the AC power cables before installing the AC RRU power cables. For details, see page 48

Page 37: 75357582-RRU3008-Installation-Guide-V300-11-1

36

Cable Connections of a Single RRUd

The AC RRU monitoring signal cable, DC RRU power cable, equipotential cable between the power module and the RRU are installed before delivery.

Sequence of Installing the Cables: PGND cable → RRU RF jumper → AC RRU power cable→ CPRI optical cable → AISG multi-wire cable between the RRU and the RCU ( optional ) →AISG extended cable between the RRU and the RCU ( optional )

1. 告警线

2. CPRI光纤

3. 直流电源线

4.互联跳线

5. AISG 多芯线

6.射频跳线

7.馈线

8. AISG延长线

9.保护地线

10.交流电源线

11. 等电位线

Antenna

Installing the AC RRU3008

1. AC RRU monitoring signal cable

2. CPRI optical cable

3. DC RRU power cable

4. RF cable between RRUs

5. AISG multi-wire cable between the RRU and the RCU

6. RRU RF jumper

7. Feeder

8. AISG extended cable between the RRU and the RCU

9. PGND cable

10. AC RRU power cable

11. Equipotential cable

Page 38: 75357582-RRU3008-Installation-Guide-V300-11-1

37

Cable Connections of Multiple RRUse

① AC RRU power cable ② PGND cable③ CPRI optical cable④ RRU RF jumper

Grounding bolt on the RRUOT terminal (M6)Equipotentialcable

(6 mm²) Grounding bolt on the power moduleOT terminal (M6)

Feeder or antennaDIN male connector

Ports labeled ANT-A and ANT-B on the RRUDIN male connectorRRU RF jumper

Nearest grounding barOT terminal (M8)

Grounding bolt on the RRUOT terminal (M6)PGND cable

(16 mm²)

Connected to…Connector TypeCable

List of Cables (No Surge Protection Box Configured)f

Installing the AC RRU3008

AntennaAntenna Antenna

Page 39: 75357582-RRU3008-Installation-Guide-V300-11-1

38

the CPRI_W port on the upper-level RRUSFP200 male connectorSFP high-speed cable for cascaded RRUs

the CPRI_E port on the lower-level RRUSFP200 male connector

Standard AISG female connector of the AISG multi-wire cable

Standard AISG male connector

AISG extended cable between the RRU and the RCU

Standard AISG male connector of the RCUStandard AISG female connector

Port labeled RX_IN/OUT on the RRU2W2 connectorRF cable between RRUs

Port labeled RX_IN/OUT on the RRU2W2 connector

Standard AISG male connector of the AISG extension cable or RCU

Standard AISG female connector

Port labeled RET on the RRUWaterproof DB9 connectorAISG multi-wire cable between the RRU and the RCU

Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU

DLC connectorCPRI optical cable

Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI5 ports on the GTMU

DLC connector

Port labeled AC IN on the RRURound connectorAC RRU power cable

(1.5mm²) External power supplyto be made depending on field requirements

Connected to…Connector TypeCable

List of Cables (No Surge Protection Box Configured)f

Installing the AC RRU3008

Page 40: 75357582-RRU3008-Installation-Guide-V300-11-1

39

List of Cables (Surge Protection Box Configured)g

the CPRI_E port on the upper-level RRUSFP200 male connectorSFP high-speed cable for cascaded RRUs the CPRI_W port on the lower-level RRUSFP200 male connector

Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI5 ports on the GTMU

Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU

DLC connectorCPRI optical cable

DLC connector

PGND cable

(16 mm²)

Nearest grounding barOT terminal (M8)

Grounding bolt on the surge protection boxOT terminal (M6)

Grounding bolt on the surge protection boxOT terminal (M6)

Grounding bolt on the RRUOT terminal (M6)Equipotentialcable

(6 mm²)

Connected to…Connector TypeCable

Installing the AC RRU3008

Page 41: 75357582-RRU3008-Installation-Guide-V300-11-1

40

Port labeled RET on the RRUWaterproof DB9 connectorAISG multi-wire cable between the RRU and the RCU Standard AISG male connector of the AISG extension cable or

RCUStandard AISG female connector

Standard AISG female connector of the AISG multi-wire cableStandard AISG male connectorAISG extended cable between the RRU and the RCU Standard AISG male connector of the RCUStandard AISG female

connector

The Lin, Nin, and PE terminals on the surge protection box OT terminalExternal AC input power cable

(4 mm2) External power supplyTo be made depending on field requirements

Port labeled RX_IN/OUT on the lower-level RRU2W2 connector

Port labeled RX_IN/OUT on the upper-level RRU2W2 connectorRF cable between RRUs

Port labeled AC IN on the RRURound connectorPower cable between RRU and the surge protection box

(1.5 mm2)

The Lout, Nout, and PE terminals on the surge protection box OT terminal

Feeder or antennaDIN male connector

Ports labeled ANT-A and ANT-B on the RRUDIN male connectorRRU RF jumper

Connected to…Connector TypeCable

List of Cables (Surge Protection Box Configured)g

Installing the AC RRU3008

Page 42: 75357582-RRU3008-Installation-Guide-V300-11-1

41

① CPRI optical cable② AC RRU monitoring signal cable③ DC RRU power cable ④ AC RRU power cable ⑤ Equipotential cable⑥ RRU RF jumper⑦ PGND cable

h Installing the RRU Cables

The cabling cavity of the AC RRU3008 is the same as that of the DC RRU3008.The procedures for opening and closing the cover for the cabling cavity of the AC RRU3008 are the same asthat of DC RRU3008

Installing the AC RRU3008

Cable Connections of RRU

Wrap the RF jumper for the RRU with the waterproof tape, and then wrap it with the PVC insulating tape.

Page 43: 75357582-RRU3008-Installation-Guide-V300-11-1

42

for Outdoor Scenarios

h

Installing the AC RRU3008

Installing the RRU Cables

for Indoor Scenarios

① CPRI optical cable② Equipotential cable③ PGND cable④ Power cable between RRU and the surge protection box⑤ External AC input power cable

① CPRI optical cable② PGND cable③ External AC input power cable

2

3

5

14

1

2

3

The maximum length of the external AC input power cable is 70 m for the 110 V AC single-phase power cable and 100m for the 220 V AC single-phase power cable.

Page 44: 75357582-RRU3008-Installation-Guide-V300-11-1

43

Installing the AC RRU3008

i Installation Checklisti

3. The OT terminals of the cables connected to the surge protection box are securely linked. The jackets of the cables are not damaged, and there are no uneven edges on the cables.

2. The waterproof gaskets on the door of the cabling cavity of the surge protection box are not stripped or broken.

1. The PG connectors labeled IN and OUT on the surge protection box are securely installed and cannot be rotated with the cables.

5. The six screws on the cabling cavity of the surge protection are tightened according to the required fastening torque.

4. The PG connectors are tightened, and the waterproof rings are secure.

9. The installation and maintenance of the surge protection box is not performed in rainy or damp weather.

8. The power supply to the surge protection box is switch off before installation and maintenance.

7. The cables in the surge protection box are correctly connected by referring to the operation guide. The OT terminals are tight linked before the door of the cabling cavity is closed.

6. The axis for the door of the cabling cavity of the surge protection box is not broken, and the surface of the protection box is not scratched.

Page 45: 75357582-RRU3008-Installation-Guide-V300-11-1

44

Powering On the RRU

Power on the RRU

Start

End

Check whether the status of the RUN LED is 1s ON, 1s OFF and that of ALM

LED is OFF.

Rectify the fault

Yes

No

When the RRU is unpacked, it must be powered on within 24 hours. Each time the RRU is maintained after being put into use, the power-off duration cannot exceed 24 hours.

Page 46: 75357582-RRU3008-Installation-Guide-V300-11-1

45

Reference

a Binding the RRU and Installation Components

定滑轮

Steering ropeLifting rope

2. Lifting the RRU and Installation Components to the Tower

2.1. Installer A climb onto the tower. Then, installer A fixes the pulley to the support of the tower platform and leads the lifting rope through the pulley. 2.2. Installer C uses a lifting rope to bind the RRU and installation components as shown in the preceding figure and then tie a knot in the steering rope at the handle of the RRU.2.3. Installer B pulls the lifting rope, and at the same time, installer C pulls the steering rope away from the tower to prevent the RRU and installation components from colliding with the tower.2.4. Installers A hold the RRU and installation components and untie the ropes.

Pulley

When lifting the RRU and installation components to the tower, prevent the RRU from colliding with the tower.The cross-sectional area of the lifting rope and steering rope is around 20 mm, not more than 25 mm. In addition, the ropes can bear the weight four times more than that of the RRU.

Do not bind the lifting rope only on the handle when lifting the RRU.

1. Bind the RRU by leading the lifting rope along the lower part of the adapting piece and through the handle, bind the main and auxiliary brackets with the lifting rope, and then bind the steering rope with the handle of the RRU, as shown in the following figures.

WARNING

Lifting rope

Steering rope

Page 47: 75357582-RRU3008-Installation-Guide-V300-11-1

46

Reference

Add two OT terminals to the end of the DC RRU power cable connecting to the RRU.

The assembling of OT terminals to the power cable must be complete before the RRU is installed on a metal pole.

-48V DC power cable -48V DC power wire

GND wireShielding layer

OT terminals

Determine lengths of power cables for different operations according to the scales on the inner side of the cover plate of the cabling cavity.

Based on the determined length, remove the jacket and shielding layer off the power cable.

Add an OT terminal to each wire.

Strip a 15 mm jacket off the power cable to reveal the shielding layer of the power cable

Remove the jacket from each wire.

b Making OT Terminals by Using a Cable Peeler (Recommended)

a Binding the RRU and Installation Components

Color tape

Corrugated pipe

3.1. Cut off a 200 mm long corrugated pipe with the diameter of 25 mm.3.2. Lead the fiber tails labeled 1A and 1B of the optical cable into the corrugated pipe by 160 mm. 3.3. Wrap up the corrugated pipe and optical cable with the color tape. 3.4. For the tower made of steel pipes, tie the black jacket to the corrugated pipe at the position 150 mm away from the color tape, and then lift the optical cable up to the tower.3.5. For the tower made of angle steel girders, carry the optical cable onto the tower when climbing up to the tower.3.6. After the optical cable is lifted up to the tower, remove the color tape and corrugated pipe before installing the optical cable.

3. Lifting the CPRI Optical Cable up to the Tower.

Page 48: 75357582-RRU3008-Installation-Guide-V300-11-1

47

Lead the wires made of the shielding layers through heat-shrinkable tubes.

Wrap the PVC insulating tape at the joint where the three wires meet.

OT terminal on the shielding layer

Reference

c Making OT Terminals at the Input End of the DC RRU Power Cable by using a Knife

Do not damage the shielding layer of the DC RRU power cable when cutting around the jacket.

WARNING

Page 49: 75357582-RRU3008-Installation-Guide-V300-11-1

48

Reference

X9

X8

X7

X6

X5

X4

X3

X2

Cord End Terminal

GNDOrangeGNDX1.7

SWITCH_INPUT1+Twisted pair

White/orangeSWITCH_INPUT1+X1.6

GNDBlueGNDX1.3

SWITCH_INPUT0+Twisted pair

White/blueSWITCH_INPUT0+X1.2

APM TX+BrownRX485_RX+X1.14

APM TX-Twisted pair

White/ brownRX485_RX-X1.13

APM RX+GreenRX485_TX+X1.11

APM RX-Twisted pair

White/ greenRX485_TX-X1.10

LabelWire Type

Wire ColorSignal name of DB15 connector

DB15 connector

Waterproof tapes

Corrugated pipes

Connector for corrugated pipes

After the corrugated pipe is installed, wrap both ends of the power cable with waterproof tapes by referring to the following figure. Wrap the joint spirally upward, downward, and then upward again.That is, the joint is wrapped by three layers of the tape. Ensure that two adjacent layers overlap with each other about half the width of the tape.

Powersystem

d Installing the Corrugated Pipes of AC Power Cable

e Pin Assignment for the Wires of the RRU Alarm Cable ( DC )

Page 50: 75357582-RRU3008-Installation-Guide-V300-11-1

49

This describes the changes in the RRU3008 Installation Guide.

Change History

11(2010-05-20)This is the eleventh commercial release. Compared with issue 10 (2010-04-10) of V300, the figures are optimized.

10(2010-04-10)This is the tenth commercial release. Compared with issue 09 (2010-03-15) of V300R008&R009, no contents are added, deleted.

09(2010-03-15)This is the ninth commercial release. Compared with issue 08 (2010-01-30) of V300R008&R009, no contents are added, deleted.

08(2010-01-30)This is the eighth commercial release. Compared with issue 07 (2009-12-30) of V300R008&R009, no contents are added, deleted.

07(2009-12-30)This is the seventh commercial release. Compared with issue 06(2009-09-30) of V300R008&R009, the installation scenarios of OMB are added.

06(2009-09-30)This is the sixth commercial release. Compared with issue 05(2009-07-15) of V300R008&R009, the installation scenarios of APM30H(Ver.B), TMC11H(Ver.B) are added.

05(2009-07-15)This is the fifth commercial release. Compared with issue 04 (2009-04-20) of V300R008, no contents are added, deleted.