Our state-of-the art

data center is one

of the most secure

and energy efficient

data centers

in the world.

3

54 5

“Our Data Center facility was called Rockan or Stingray in English referring to the animal’s stealth and observation abilities.

In the early 70’s at the height of the Cold War, construction began on what was designed to become the Swedish Air Force’s radar command center outside Linköping. In Sweden military facilities are named after animals and civilian installations after flowers.

Our Data Center facility was called Rockan or Stingray in English referring to the animal’s stealth and observation abilities.

The construction process applied all the latest military and civilian technology

to create an installation that could not only survive a direct nuclear

strike, but also carry on its mission in a post-nuclear

environment.

One of the many interesting design features include a kilometer-long tunnel devised to divert a nuclear shockwave away from the inner areas of the center. In the transit area from the outer tunnels to the core area are decontamination zones where staff could shower off radioactive material and throw their clothing in radioactive bins for incineration.

Further features include a 100 000-liter diesel silo for running the facility during power outages. The facility even has infrastructure in place where it can maintain operations without opening its doors as new fuel can be refilled from the outside via pumps located in the blast tunnel. In the late 90’s during the second stage of construction, additional upgrades and a much larger inner area were created in order to improve the facility’s communications ability.

History

Our Data Center facility was called Rockan or Stingray in English referring to the animal’s stealth and observation abilities.

Our Data Center facility was Our Data Center facility was Our Data Center facility was called Rockan or Stingray called Rockan or Stingray called Rockan or Stingray in English referring in English referring in English referring to the animal’s stealth to the animal’s stealth to the animal’s stealth and observation abilities.and observation abilities.and observation abilities.

Our Data Center facility was called Rockan or Stingray in English referring to the animal’s stealth and observation abilities.

4

76

• The facility is situated 60 meters underneath a granite mountain able to withstand a 2.5 Megaton direct nuclear strike.

• Sweden has one of the largest fibre networks in the world covering Europe, Americas and Asia. The rates are favourable.

• Network uplinks consist of six fiber paths for 344 pairs, one satellite uplink and one microwave link.

• Circle fed power.

• Sweden has a legal system and laws that favour data security and data privacy. Law enforcement is obliged to follow these rules.

• Redundant Piller diesel generators.

• Flywheel UPS system

• PuE* < 1.1 vs industry standard of 1.7 (* Power Usage Effectiveness)

• Sweden top ranked in GPI (Global Peace Index)

76

ColocationSpace located in a shared rack where

you rent the acquired numbers of Units

for your needs.

Private RackProvides you with a dedicated, locked

rack with 50 units.

Private CageProvides you with your own secure

area within a shared colocation area.

Private RoomA dedicated private room tailor built to

your specific requirements. Separated

from other customer areas by enclosed

walls. Climate control, fire suppression

system, power and access control are

exclusive to your room.

Managed ColocationRockan Data Center provides

customers with engineering staff at

short notice to assist with data center

support 24/7/365. The staff will follow

the customer instructions performing

the tasks requested.

Why choose ROCKAN Data Center?

98

GENERALOwner Rockan Data Center AB

Founded 2007

Company HQ Skogängsvägen 59, 163 41 Spånga, Sweden

Data Center location Solvestad, Åtvidaberg, Sweden

Accesibility Stockholm 250 km. Linköping 50 km, Jönköping 190 km

Accesibility - air Helicopter transport from Stockholm city centre to own helicopter platform

Accesibility - public transportation Public transport (bus 535) stops close to facility (400 m)

Accesibility - highway Local road (35) outside facility - 100 m from outer building

Parking spaces 20 spaces outside the data center enclosure, 6 inside security perimitor.

Delivery access Security Zone 2 with loading dock

Power Supply E.On

Substations Two independent substations

Data Retention Data is held in-house at our fortifi ed deposit box tunnel.

Expansion possibilities We can accommodate any size customer, and also replica-te to off -site locations.

Purpose Former Swedish millitary facility used as radar observation facility. Fully rebuilt to state of the art secure data center

FACTS AND FİGURESSite size 11000 m2 with tunnels

Gross fl oor area 2400 m2

Useable data center area 4000 m2

Equivalence in available IT racks (approx)

1150 physical racks

RİSK ANALYSİSCivil risks Sweden top ranked in GPI (Global Peace Index)

Natural risks No risk of natural catastrophys (e.g. Earthquakes and fl ooding)

Industrial risks No industries with dangerous goods or high amount of people traffi c

Transport risks Safe distance to international airports, national traffi c corridors (road and rail traffi c) and to large urban areas

BUİLDİNG SECURİTYType of construction Facility carved out into solid granite bedrock

Security perimeter Three Security Zone Permitors

Use Fortifi ed radar command center, designed to continue operations in stand alone mode in the event of loosing communication with outside world (i.e nuclear war, disaster)

Security personel 24/7/365 on site

Audio/video surveillance Day/night capable UHD cameras with continuous recording

Number of interlocks "Two Separate personnel and goods interlocks

Personnel interlocks Separation system with badge and pin code checks as well as Iris scanners

POWER SUPPLYFeed Circle fed from two substations

Number of substations Electricity from 2 independent substations

number of substations Electricity from two independent substations

Emergency power 10-14 days of autonomous emergency power

Diesel generators Three diesel generators (4.5 mW) of Piller brand. Expan-dable to six.

Diesel tanks Two diesel tanks (60K liter & 40K liter) which can be refuelled under operation

Electromagnetic compatibility Protection against overvoltage/undervoltage, residual current and lightening. EMP protection.

Transformator station Inside the facility

Uninterruptible power supply N+1 redundancy

Available power Maximum 63 amps per rack.

COOLİNG SYSTEMSCooling technology Cooling provided by fresh outside air and geothermal

properties of the mountain.

Waste heat utilization Potentially used for heating commercial greenhouse operations

Cooling concept Hot and Cold Aisle design

Power supply Powered supplied redundantly

Key fi gures Rockan Data Center

8 9

FİRE PROTECTİONFire protection zones Each rack and/or pod acts as its own fi re zone

non-combustible calcium sulphate data center fl ooring system. Water mist suppression possible upon request

Extinguishing systems "The facility is equipped with stat-x fi re suppression systems and water mist.

Early fi re detection Early warning laser smoke detectors

CONNECTİVİTYPrinciple Carrier-neutral data center

Multiple available carriers Our feeds will be able to service anyone on http://www.netnod.se/ix/members

Building access The data center is connected with quad-entry fi beroptic connections

Telecom Meet-me rooms Redundant

Network Uplinks Currently six fi ber paths for 344 pairs, one satellite uplink, one microwave link

HOUSİNG PREMİSESStatic load per sq m of subfl ooring 1.6 ton per square meter

Ceiling clearance 8 meters

Depth of subfl ooring (Gross fl oor DC area)

2000m2 1000 mm 400m2 500mm

GREEN/IT/ECOLOGYEnergy-optimized architecture

Power Usage Eff ectiveness (PuE) < 1.1

Energy Management Comprehensive ISO 50001 energy management

Renewable energy source - hydro power

100 % power available from Swedish hydroelectric stations

Renewable energy source - solar power

Roof of exterior housing covered in solar panels

Cooling technology

INFRASTRUCTURE MANAGEMENT SYSTEMInfrastructure Management System Real-time measurements and ongoing analysis of all data

center relevant operating parameters . Open API for statis-tics for customers with own monitoring appliances

CUSTOMİZED PACKAGESData center space Customized pod

Colocation 1u to 100 racks

Planning and setup Of specifi c customer data center infrastructure (deploy-ment)

Inter-rack cabling Pre-installed cable ladders for pods, pre-terminated fi ber for dc interconnectivity

Regular and emergency workplaces 12 rooms, excluding emergency space, 16 beds

Use of common rooms Staging and conference rooms available

SERVİCE LEVEL AGREEMENTPower supply 99.999 % availability in line with Uptime Institute Tier-IV

Temperature 14 degrees to 18 degrees

Humidity 50 % to 60 %

CONTACTTelephone +46(0) 8 10 48 18

E-mail [email protected]

Website www.rockan.com

Twitter @Rockan_DC

Linkedin www.linkedin.com

Facebook www.facebook.com/rockanstingray

1110

Frederik VynckeCEO

[email protected]+46 (0)76 306 42 36

Elon BjörinCTO

[email protected]+46 (0)73 788 91 06

Daniel WernerChairman of the Board

[email protected]+46 (0)73 524 2490

TeamInterested to

find out more about

ROCKAN Data Center

and what we can mean

for you and your company?

Contact us for more information.

We are certain to be of great value to you.