Design of Plate Frame Design of Plate Frame HeatHeat
ExchangerExchangerAdil Akbar(Me-029)Arsalan Hanif(Me-035)Muhammad Bilal(Me-027)Usama Najeeb(Me-080)
Final year ProjectBatch 2007-2008
![Page 2: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/2.jpg)
ObjectiveObjective To design a plate frame
heat exchanger to achieve the desired heat transfer duty with minimum pressure, drop and to keep the design
as close as possible to the .actual design
![Page 3: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/3.jpg)
Milestones CompletedMilestones Completed
![Page 4: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/4.jpg)
Remaining MilestonesRemaining Milestones
![Page 5: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/5.jpg)
Literature StudyLiterature Study
![Page 6: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/6.jpg)
Lite ra tu re S tu d y. . . . .co n tin u e s
![Page 7: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/7.jpg)
Executed WorkExecuted WorkApplication/Design SpecificationFunction: - To pre cool milk using water for
.pasteurization
Warm side Cold side
Fluid Milk Water
Inlet temp 50°C 32°C
Outlet temp 35.88°C 41.38°C
Max. allowable pressure drop
0.22bar 0.44bar
Mass flow rate 3.103kg/s 4.130kg/s
![Page 8: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/8.jpg)
Executed Work Executed Work Continues.....Continues.....Introduction to Thermal Design
ProcedureLimited literature is available as design equations and correlations are usually company secret.
Design softwares are not easily available.We have used correlations developed by scientists through research work namely Kumar(1984), Talik(1995) and Focke(1985).
Chevron angle for Talik and
.Focke
Chevron angle .for Kumar
![Page 9: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/9.jpg)
Executed Work Executed Work Continues.....Continues..... Effect of changing chevron angle using Kumar correlation
Angle U( /W m2. )K
No.plates
No.passes
P_tm(bar)
P_tw(bar)
30° 1266.6 45 2 0.2014 0.2831
45° 1266.6 45 2 0.08516 0.1146
60° 850.67 67 3 0.06418 0.08517
![Page 10: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/10.jpg)
EExecuted Work Continues.....xecuted Work Continues.....Graph between chevron angle and overall heat transfer coefficient.
Graph between chevron angle and total pressure drop for milk.
![Page 11: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/11.jpg)
Graph between chevron angle and total pressure drop for water.
Executed Work Continues.....Executed Work Continues.....
° Results derived from these graphs is that 45 is optimum angle as overall heat transfer coefficient is maximum and
.pressure drop is moderate
![Page 12: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/12.jpg)
Executed Work Continues.....Executed Work Continues.....Comparison of Kumar, Talik and Focke correlations.
Correlations U(W/m2.K)
No.plates
No.passes
P_tm(bar)
P_tw(bar)
Kumar(45°) 1266.5 45 2 0.08516 0.1146
Talik(60°) 1266.5 45 2 0.03190 0.09412
Focke(45°) 2478.5 23 1 0.05609 0.1152
![Page 13: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/13.jpg)
Executed Work Continues.....Executed Work Continues.....
Kumar and Focke correlations verify that 45° is an optimum chevron angle.
![Page 14: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/14.jpg)
Executed Work Continues.....Executed Work Continues.....Effect of varying plate size at chevron angle of 45°using Kumar correlation.Size Width(m) length(m) Port
Dia(m)1 0.15 0.7 0.082 0.30 0.50 0.123 0.30 0.80 0.124 0.40 0.80 0.155 0.40 1.20 0.156 0.60 1.00 0.157 0.60 1.40 0.158 0.80 1.00 0.189 0.80 1.40 0.1810 0.80 1.60 0.18
= , = .b 4mm plate thickness 0 65mm
![Page 15: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/15.jpg)
Executed Work Continues.....Executed Work Continues.....
Size U(W/m2.K)
No.plates
No.passes
P_tm(bar
P_tw(bar)
1 1681 155 7 .1 0220 .1 3847
2 1371.3 133 6 .0 1803 .0 2442
3 1280.8 89 4 .0 1912 .0 2583
4 1276 67 3 .0 0853 .0 1151
5 1266.6 45 2 .0 0851 .0 1147
6 1013.2 45 2 .0 0345 .0 0466
7 1416 23 1 .0 0241 .0 0325
8 759.9 45 2 .0 0206 .0 0277
9 1062 23 1 .0 0143 .0 0193
10 929.3 23 1 .0 0164 .0 0221
Result of varying plate size
![Page 16: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/16.jpg)
Executed Work Continues.....Executed Work Continues.....
![Page 17: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/17.jpg)
Executed Work Continues.....Executed Work Continues.....
We arbitrarily selected size no.5 as a suitable plate size for our calculations.
![Page 18: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/18.jpg)
Executed Work Continues.....Executed Work Continues.....
The results obtained using Kumar’s correlation are in accordance to the data obtained from Engro Foods.
Also Kumar is the most widely used correlation for plate frame heat exchanger.
Summary Of Thermal Design
Kumar U(W/m2.K)
No.plates
No.passes
P_tm(bar)
P_tw(bar)
Plate Width(m)
Plate length(m)
Port Dia(m)
45° 1266.5 45 2 0.085160.1146 0.4 1.2 0.15
![Page 19: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/19.jpg)
Plan to do Remaining WorkPlan to do Remaining Work
![Page 20: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/20.jpg)
Plan to do Remaining Work Plan to do Remaining Work cont.....cont.....
HEAT TRANSFER REGION ASSEMBLY( )plates and gaskets
( SUPPORT ASSEMBLY support, , brackets clamping plates
, tie rods tightening )bolts and nuts etc
![Page 21: 58147251 Design of Plate Frame Heat](https://reader036.vdocuments.site/reader036/viewer/2022081720/5402e0a1dab5cafa2c8b47cf/html5/thumbnails/21.jpg)
ReferencesReferences ( Plate Heat Exchangers Design Application and
) . , . . . Performance by L WANG B SUNDEN and R MMANGLIK
Heat Exchangers by Sadik Kakac 2nd Edition CRC.Press
Heat Exchangers by Holger Martin CRC Press 1 edition
. C om pact H eat Exchangers by JEH ESSELG R EAV ES
IndustrialH eat Exchangers A B asic G uide 2 nd Edition by G Walker
Introduction to Food Process Engineering By P .G Smith